Ready to installDistribution and protection products
2
3
ContentsDomae consumer units . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 4Features and benefits . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 5Quick selector - reference numbers and descriptions . . . . . . . . . . . . . . . . . . . . . . . . . 6Consumer unit - dimensions and technical data . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 8Devices - technical data . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 9
Qwikline ll consumer units . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 10Features and benefits . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 11Quick selector - reference numbers and descriptions . . . . . . . . . . . . . . . . . . . . . . . . 12Standard consumer units - technical data . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 14Split load consumer units - technical data . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 15Dual/multi tariff consumer units - technical data . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 16Devices - technical data . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 17
LoadCentre KQ distribution boards . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 18Single phase A type distribution boards - 125A . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 19Three phase B type distribution boards - 250A . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 21Three phase B type distribution boards - metered . . . . . . . . . . . . . . . . . . . . . . . . . . . 22iKQ miniature circuit breakers (MCB’s) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 24Residual current circuit breakers (RCBO’s) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 25Residual current circuit breakers (RCCB’s) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 26Extension enclosures . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 27
Panelboards . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 28I-Line MCCB panelboards Size 1 250A . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 29I-Line MCCB panelboards Size 1 400A . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 32I-Line MCCB panelboards Size 2 630A . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 35Panelboard accessories . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 40MCCB accessories . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 42Metering facilities . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 44
Switch and fusegear . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 46Twinbreak . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 47Quadbreak . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 48Quadbreak busbar chambers . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 49Quadbreak dimensions . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 50
Index . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 51
4
Domae consumer unitsThe Domae range of consumer units offers the ultimate in terms of onsite flexibility at a very affordable price .
There are no bespoke split load consumer units, however any
Domae enclosure can be taken and used with a single incomer or
converted to a split load board with the minimum of effort.
A wide range of RCD protected and unprotected ways is possible and a standard board can be converted to a split load type at any time in the future. In terms of safety Domae offers a wide range of protective devices and installer safety is maximised via a busbar shield which, once fitted, can only be removed with the use of a tool.
Domae is now available with insulated or metal enclosures.
5
Domae consumer unitsFeatures and benefits
Highly flexible Domae consumer units can be used with a single main incomer or used as a split load board
Configurable on site Choose the split of protected or unprotected RCD ways. Standard single incomer boards can be converted to split load at a later date
Ideal for rewire applications Right hand incomer for easier installation where existing incoming cables fall on the right
Controls flexibility Control devices can be easily installed within the same enclosure
Additional installer safety The busbar shield is firmly held in place when fitted and requires a tool to remove
Value for money Backed by the Schneider Electric brand you can be assured that Domae is a cost effective and quality solution
6
Domae - quick selector
Select consumer unitInsulated units
Reference number No. of ways Reference number No. of waysDOM2CU 2 DOM2MCU 2
DOM4CU 4 DOM4MCU 4
DOM6CU 6 DOM6MCU 6
DOM8CU 8 DOM8MCU 8
DOM12CU 12 DOM12MCU 12
DOM16CU 16 DOM16MCU 16
DOM20CU 20
Select incoming deviceMain incoming devices
Reference number Description Current rating
DOM63SW Switch 63A
DOM100SW Switch 100A
DOM63R30 RCCB 63A 30mA
DOM80R30 RCCB 80A 30mA
DOM100R100 RCCB 100A 100mA
DOM100R100SP RCCB (TD) 100A 100mA
DOM100R30P RCCB 100A 30mA
For split load applications select a split load kitSplit load kits [includes cables and RCCB (RCD)]
Reference number Description Current rating
DOM63R30KIT2 RCCB and cables 63A 30mA
DOM80R30KIT2 RCCB and cables 80A 30mA
Select consumer unit packagePre-assembled ready to install consumer unit packages
Reference number Description Typical application
SHOWER6340D 2 way enclosure + 63A 30mA RCCB and 40A MCB Electric shower supply
SHOWER6345D 2 way enclosure + 63A 30mA RCCB and 45A MCB Electric shower supply
GARAGE63D 2 way IP55 enclosure + 63A RCD, 6A and 16A MCB Electricity supply to a garage
Select consumer units with switch/RCD’s fittedSplit load kits [includes cables and RCCB (RCD)]
Reference numberInsulated Units
Reference numberMetal units
Total no. ways
DescriptionSwitch only ways
RCD1 protected ways
RCD2 protected ways
DOMR4R4CU DOMR4R4MCU 8 4 + 4 way configurable Domae CU 100A Sw and 2 63A RCDs
4 4
DOMR6R6CU DOMR6R6MCU 12 6 + 6 way configurable Domae CU 100A Sw and 2 63A RCDs
6 6
DOMR6R6DCU DOMR6R6DMCU 12 6 + 6 way configurable Domae CU 100A Sw and 2 80A RCDs
6 6
DOMR8R8DCU 16 8 + 8 way configurable Domae CU 100A Sw and 2 80A RCDs
8 8
DOMS2R5R5DCU DOMS2R5R5DMCU 12 2 + 5 + 5 way Domae CU 100A Sw and 2 80A RCDs
2 5 5
DOMS2R7R7DCU 16 2 + 7 + 7 way Domae CU 100A Sw and 2 80A RCDs
2 7 7
Metal units
7
Domae - ready to install consumer unit packagesDomae ready to install consumer unit packages are supplied complete with enclosure, incoming and outgoing devices and all internal connections required. Order 1 part number then simply fix, connect, test and energise.
Select outgoing devices or accessoriesSP 6kA MCBs (B curve)
Reference number Description Current rating
DOM03B6 MCB (B curve) 3A
DOM06B6 MCB (B curve) 6A
DOM10B6 MCB (B curve) 10A
DOM16B6 MCB (B curve) 16A
DOM20B6 MCB (B curve) 20A
DOM32B6 MCB (B curve) 32A
DOM40B6 MCB (B curve) 40A
DOM45B6 MCB (B curve) 45A
DOM50B6 MCB (B curve) 50A
SP 6kA MCBs (C curve)
Reference number Description Current rating
DOM06C6 MCB (C curve) 6A
DOM10C6 MCB (C curve) 10A
DOM16C6 MCB (C curve) 16A
Accessories
Reference number Description
DOMLKIT Door lock kit (for metal enclosure only)
DOMEARTHKIT Additional earth terminals for clean earth or high integrity earthing
DOM16BKIT Replacement/spare main busbar
SQODNBP Blanking plate
SP 6kA 1 module RCBO (B curve)
Reference number Description Current rating
DOM06B6R30 RCBO 30mA 1 Module 1P&N 6A
DOM10B6R30 RCBO 30mA 1 Module 1P&N 10A
DOM16B6R30 RCBO 30mA 1 Module 1P&N 16A
DOM20B6R30 RCBO 30mA 1 Module 1P&N 20A
DOM32B6R30 RCBO 30mA 1 Module 1P&N 32A
DOM40B6R30 RCBO 30mA 1 Module 1P&N 40A
DOM45B6R30 RCBO 30mA 1 Module 1P&N 45A
Insulated kitboxPre-assembled ready to install consumer unit packages
Reference number Description Typical application
KITBOXD 12 way enclosure, switch, 63A 30mA RCCB kit, 3 x 6A MCB’s, 2 x 16A MCB’s, 4 x 32A MCB’s, 1 x 40A MCB
General residential rebuild or rewire
KITBOXD80 12 way enclosure, switch, 80A 30mA RCCB kit, 3 x 6A MCB’s, 2 x 16A MCB’s, 4 x 32A MCB’s, 1 x 40A MCB
General residential rebuild or rewire
Metal kitboxPre-assembled ready to install consumer unit packages
Reference number Description Typical application
KITBOXDM 12 way enclosure, switch, 63A 30mA RCCB kit, 3 x 6A MCB’s, 2 x 16A MCB’s
General residential rebuild or rewire
KITBOXDM1263 12 way enclosure, switch, 63A 30mA RCCB kit, 2 x 6A MCB’s, 2 x 16A MCB’s, 3 x 32A MCB’s, 1 x 40A MCB
General residential rebuild or rewire
KITBOXDM1280 12 way enclosure, switch, 80A 30mA RCCB kit, 3 x 6A MCB’s, 2 x 16A MCB’s, 3 x 32A MCB’s, 1 x 40A MCB
General residential rebuild or rewire
8
Domae consumer units - dimensions & technical data
Insulated unitsReference number No. of ways Height (mm) Width (mm) Depth (mm)
DOM2CU 2 240 189 127
DOM4CU 4 240 224 127
DOM6CU 6 240 260 127
DOM8CU 8 240 296 127
DOM12CU 12 240 368 127
DOM16CU 16 240 440 127
DOM20CU 20 240 510 127
DOMR4R4CU 8 240 368 127
DOMR6R6CU 12 240 440 127
DOMR6R6DCU 12 240 440 127
DOMS2R5R5DCU 12 240 440 127
DOMR8R8DCU 16 240 510 127
DOMS2R7R7DCU 16 240 510 127
Metal unitsReference number No. of ways Height (mm) Width (mm) Depth (mm)
DOM2MCU 2 247 186 111
DOM4MCU 4 247 222 111
DOM6MCU 6 247 258 111
DOM8MCU 8 247 294 111
DOM12MCU 12 247 366 111
DOM16MCU 16 247 438 111
DOMR4R4MCU 8 247 366 111
DOMR6R6MCU 12 247 438 111
DOMR6R6DMCU 12 247 438 111
DOMS2R5R5DMCU 12 247 438 111
Technical dataMax. busbar current (A) 100A
Max. operating voltage 230/240V @ 50Hz
Max. cable capacity 25 mm2 (earth and neutral bars)
Certification BS EN 61439-3
Note: Incoming and outgoing devices must be selected separately from the devices section - only applies to DOM**CU and DOM**MCU
Incoming devices available• Switch disconnector 63A & 100A• RCCB’s 63A/30mA 80A/30mA
Max. busbar splits - for split load8 way 2+4 to 4+212 way 4+6 to 6+416 way 6+8 to 8+6
Fully configurable shrouded busbars
Lockable cover option on metal units
9
Domae - device & technical data
Incoming devices - selection and technical data
Referencenumber Description No.
polesCurrentrating
Operatingvoltage (V)
Max. cableCap. mm2
Standardsapproval
Recommended tightening torque
DOM63SW Switch 2 63A 230/240 35 BS EN 60947-3 3.5 N.m.
DOM100SW Switch 2 100A 230/240 50 BS EN 60947-3 3.5 N.m.
DOM63R30 RCCB 2 63A 30mA 230/240 35 BS EN 61008 3.5 N.m.
DOM80R30 RCCB 2 80A 30mA 230/240 50 BS EN 61008 3.5 N.m.
DOM100R100 RCCB 2 100A 100mA 230/240 50 BS EN 61008 3.5 N.m.
DOM100R100SP RCCB (TD) 2 100A 100mA 230/240 50 BS EN 61008 3.5 N.m.
DOM100R30P RCCB 2 100A 30mA 230/240 50 BS EN 61008 3.5 N.m.
Outgoing 6kA MCBs and RCBOs
Referencenumber Description No.
polesCurrentrating
Operatingvoltage (V)
Max. cableCap. mm2
Standardsapproval
Recommended tightening torque
Single pole circuit breaker (B curve)
DOM03B6 MCB 1 3A 230/240 25 BS EN 60898 2 N.m.
DOM06B6 MCB 1 6A 230/240 25 BS EN 60898 2 N.m.
DOM10B6 MCB 1 10A 230/240 25 BS EN 60898 2 N.m.
DOM16B6 MCB 1 16A 230/240 25 BS EN 60898 2 N.m.
DOM20B6 MCB 1 20A 230/240 25 BS EN 60898 2 N.m.
DOM32B6 MCB 1 32A 230/240 35 BS EN 60898 3.5 N.m.
DOM40B6 MCB 1 40A 230/240 35 BS EN 60898 3.5 N.m.
DOM45B6 MCB 1 45A 230/240 35 BS EN 60898 3.5 N.m.
DOM50B6 MCB 1 50A 230/240 35 BS EN 60898 3.5 N.m.
Single pole circuit breaker (C curve)
DOM06C6 MCB 1 6A 230/240 25 BS EN 60898 2 N.m.
DOM10C6 MCB 1 10A 230/240 25 BS EN 60898 2 N.m.
DOM16C6 MCB 1 16A 230/240 25 BS EN 60898 2 N.m.
Single pole circuit breaker (B curve)
DOM06B6R30 1 Module RCBO 1 6A 230/240 25 BS EN 61009 2 N.m.
DOM10B6R30 1 Module RCBO 1 10A 230/240 25 BS EN 61009 2 N.m.
DOM16B6R30 1 Module RCBO 1 16A 230/240 25 BS EN 61009 2 N.m.
DOM20B6R30 1 Module RCBO 1 20A 230/240 25 BS EN 61009 2 N.m.
DOM32B6R30 1 Module RCBO 1 32A 230/240 25 BS EN 61009 2 N.m.
DOM40B6R30 1 Module RCBO 1 40A 230/240 25 BS EN 61009 2 N.m.
DOM45B6R30 1 Module RCBO 1 45A 230/240 25 BS EN 61009 2 N.m.
Qwikline II consumer unitsThe Qwikline II range of consumer units provides arguably the highest levels of residential circuit protection safety .A wide range of switch disconnectors, RCDs and MCBs is also complimented by a single pole RCBO offer for maximum continuity of supply in the event of fault.
What really sets Qwikline II apart, is the plug-on breaker concept and fully encapsulated busbars. All outgoing devices can be connected in seconds and with no incoming terminal to tighten, the correct mechanical connection force is guaranteed every time. For unused ways, Qwikline II’s unique fully encapsulated busbar system means that the highest levels of installer and end user protection are always guaranteed.
Even with the front cover of the enclosure removed, the main busbar is protected to IP2X, meaning it remains finger safe but allows access with test probes by the installer.
For energy management and safety Qwikline II can also accept a wide range of control devices.
10
Qwikline ll consumer unitFeatures and benefits
Tested in accordance with BS EN 61439-3 and CM16 tested
Unrestricted cable entry can be made from any side
Totally encapsulated busbar system. Provides complete finger safety to IP2XB, bringing new levels of safety to consumer unit design
Incoming devices can be ordered separately giving over 1000 combinations from just 46 references
Single pole RCBO. Tested to BS EN 61009
Unique MCB/RCBO fixing system. Retains plug-on philosophy for speed of installation and guaranteed connections. Provides the additional benefit of a rear clip which increases device security once plugged on
Control devices may be installed on any outgoing way. No extra mounting accessories required
Lockable cover option now available on metal units
11
12
Qwikline ll - quick selector
Select consumer unit: insulated unitsStandard
Referencenumber
No. ofways
Referencenumber Cir A RCD ways
Referencenumber Cir A Cir B
SQO2 2 SQOS2R4 2 4 SQO204 2 4
SQO4 4 SQOS3R3 3 3 SQO303 3 3
SQO6 6 SQOS4R2 4 2 SQO402 4 2
SQO8 8 SQOS4R6 4 6 SQO406 4 6
SQO12 12 SQOS5R5 5 5 SQO505 5 5
SQO16 16 SQOS6R4 6 4 SQO604 6 4
SQO23 24 SQOS7R3 7 3 SQO703 7 3
SQOS7R7 7 7 SQO707 7 7
Select consumer unit: metal unitsStandard
Referencenumber
No. ofways
Referencenumber Cir A RCD
ways
Referencenumber Cir A Cir B
Referencenumber Cir A Cir B Cir C
SQOM2 2 SQOMS4R6 4 6 – – – SQOM60501 6 5 1
SQOM4 4 SQOMS5R5 5 5 SQOM505 5 5 SQOM70401 7 4 1
SQOM6 6 SQOMS6R4 6 4 SQOM604 6 4
SQOM8 8 SQOMS7R7 7 7 SQOM707 7 7
SQOM12 12
SQOM16 16
SQOM 24 24
Split load
Split load
Dual incomer
Dual incomer Multi tariff
No. of ways
No. of ways
No. of ways
No. of ways No. of ways
Mutliple split busbars - supplied with switch disconnectors and RCDs
Mutliple split busbars - supplied with switch disconnectors and RCDs
Reference number Total ways Switch ways RCD 1 ways RCD 2 ways
SQOSR6R6 12 – 6 (63A) 6 (63A)
SQODS2R5R5 12 2 5 (100A) 5 (100A)SQOS2R5R5 12 2 5 (63A) 5 (63A)
Reference number Total ways Switch ways RCD 1 ways RCD 2 ways
SQOMSR6R6 12 – 6 (63A) 6 (63A)
SQOMDS2R5R5 12 2 5 (100A) 5 (100A)SQOMS2R5R5 12 2 5 (63A) 5 (63A)
Note: Flush mounted standard metal consumer units are available by adding an ‘F’ suffix to the above part numbers. e.g. SQOM2F = 2 way flush mounted unit.For flush mounting of split load, dual incomer and multi tariff boards use SQOFC12 for 10 module boards and SQOFC16 for 14 module boards.
Note: All Qwikline II consumer units are supplied without incoming devices. Any incoming device may be installed at the incoming point, or busbar split in any Qwikline II consumer unit.
Requirements Standard units – 1 incoming device required.Split load units – 1 main incoming device and 1 busbar split device required.
Dual incomer units – 2 incoming devices required.Multi tariff units – 3 incoming devices required.
Select incoming devicesReference number Description No. of poles Current rating
SQO1100M 2 pole switch disconnector 2 100A
SQO1100L 2 pole terminal block 2 100A
SQOE100030 RCCB 2 100A, 30mA
SQOE100100 RCCB 2 100A, 100mA
SQOE100300 RCCB 2 100A, 300mA
SQOE100100S RCCB 2 100A, 100mA TD
SQOE063030 RCCB 2 63A, 30mA
SQOE063100 RCCB 2 63A, 100mA
13
Note: All control devices are suitable for mounting in any Qwikline II consumer unit.
Qwikline ll - quick selector
Select outgoing devicesSP 6kA MCBs (B curve)
Reference number Description Current rating
SQO103EB6 MCB (B Curve) 3A
SQO106EB6 MCB (B Curve) 6ASQO110EB6 MCB (B Curve) 10ASQO116EB6 MCB (B Curve) 16ASQO120EB6 MCB (B Curve) 20ASQO125EB6 MCB (B Curve) 25ASQO132EB6 MCB (B Curve) 32ASQO140EB6 MCB (B Curve) 40ASQO150EB6 MCB (B Curve) 50ASQO163EB6 MCB (B Curve) 63A
Select control devices and accessoriesReference number Device Ways occupied
15959 2P 25A contactor 1
15962 4P 25A contactor 215966 2P 40A contactor 215967 3P 40A contactor 315968 4P 40A contactor 315972 3P 63A contactor 315510 1P Impulse relay (16A) 115520 2P Impulse relay (16A) 115535 Changeover relay (10A) 115321 Bell (8-12V) 115214 Transformer 240-8V (4VA) 215323 Buzzer (8-12V) 1CCT15368 Light sensitive switch 3.515336 Single pole time switch 24hr 1CCT15720 Single channel electrical time switch 7 day 2.5CCT15722 Dual channel electrical time switch 7 day 2.515363 1P Delay off timer 1
SP 6kA MCBs (C curve)
Reference number Description Current rating
SQO103EC6 MCB (C Curve) 3A
SQO106EC6 MCB (C Curve) 6ASQO110EC6 MCB (C Curve) 10ASQO116EC6 MCB (C Curve) 16ASQO120EC6 MCB (C Curve) 20ASQO125EC6 MCB (C Curve) 25ASQO132EC6 MCB (C Curve) 32ASQO140EC6 MCB (C Curve) 40ASQO150EC6 MCB (C Curve) 50ASQO163EC6 MCB (C Curve) 63A
SP 6kA 1 Module RCBO (B curve)
Reference number Description Current rating
SQOR106B03 RCBO (30mA) 1 Module 1P&N 6A, 30mASQOR110B03 RCBO (30mA) 1 Module 1P&N 10A, 30mASQOR116B03 RCBO (30mA) 1 Module 1P&N 16A, 30mASQOR120B03 RCBO (30mA) 1 Module 1P&N 20A, 30mASQOR132B03 RCBO (30mA) 1 Module 1P&N 32A, 30mASQOR145B03 RCBO (30mA) 1 Module 1P&N 45A, 30mA
Accessories
SQODNBP DIN blanking plates 5CPS9 Half mod spacer 0.5QOEPLA Padlock device (suitable for use with all Qwikline II devices) –QOPL Padlock –DOMLKIT Door lock kit (metal units only) –
14
Qwikline ll - standard consumer unit technical data
Insulated unitsReference number No. of ways Height (mm) Width (mm) Depth (mm)
SQO2 2 240 189 127
SQO4 4 240 224 127
SQO6 6 240 260 127
SQO8 8 240 296 127
SQO12 12 240 368 127
SQO16 16 240 440 127
SQO23 24 480 368 127
SQOSR6R6 12 240 440 127
SQOS2R5R5 12 240 440 127
SQODS2R5R5 12 240 440 127
Metal unitsReference number No. of ways Height (mm) Width (mm) Depth (mm)
SQOM2 2 247 186 111
SQOM4 4 247 222 111
SQOM6 6 247 258 111
SQOM8 8 247 294 111
SQOM12 12 247 366 111
SQOM16 16 247 438 111
SQOM24 24 247 366 111
SQOMSR6R6 12 247 438 111
SQOMDS2R5R5 12 247 438 111
SQOMS2R5R5 12 247 438 111
Note: Incoming and outgoing devices must be selected separately from the Qwikline ll devices section. The following ref’s are supplied with switch disconnector and RCDs fitted:- SQOSR6R6, SQOS2R5R5, SQODS2R5R5, SQOMSR6R6, SQOMSR5R5, SQOMDSR5R5
Incoming devices available• Switch disconnector – 100A• Terminal block – 100A• RCCB’s – 63A/30mA, 63A/100mA, 100A/30mA, 100A/100mA, 100A/300mA, 100A/100mA TD
Technical dataMetal Insulated
Max. busbar current rating (A) 100 100
Max. operating voltage (V) 240 240
Operating frequency (Hz) 50 50
Max. incoming cable capacity mm2 (phase and neutral) 50 50
Max. outgoing cable capacity mm2 25 25
Certification BS EN 61439-3 BS EN 61439-3
IP rating BS EN 60529 (internal) 2XB 2XB
IncomingSwitch disconnector – 100ATerminal block – 100ARCCB’s – 63 or 100A/30mA, 100 or 300mA
OutgoingMCB’s – B or C curve, 3 - 50A, 6kARCBO’s – B curve 6 - 45A, 6kA
15
Qwikline ll - split load consumer unit technical data
Insulated units
Reference numberCir A RCD ways Height Width Depth
SQOS2R4 2 4 240 296 127
SQOS3R3 3 3 240 296 127
SQOS4R2 4 2 240 296 127
SQOS4R6 4 6 240 368 127
SQOS5R5 5 5 240 368 127
SQOS6R4 6 4 240 368 127
SQOS7R3 7 3 240 368 127
SQOS7R7 7 7 240 440 127
Metal units
Reference numberCir A RCD ways Height Width Depth
SQOMS4R6 4 6 247 366 111
SQOMS5R5 5 5 247 366 111
SQOMS6R4 6 4 247 366 111
SQOMS7R7 7 7 247 438 111
Note: Split load units are supplied without incoming devices. These should be selected separately from the Qwikline ll devices section. e.g. SQOS2R4 + SQO1100M + SQOE063030 = 2+4 Split load insulated consumer unit supplied with site installable switch disconnector and 63A 30mA RCCB.
Any RCCB may be selected as the main incomer or split portion device.
Technical dataMetal Insulated
Max. busbar current rating (A) 100 100
Max. operating voltage (V) 240 240
Operating frequency (Hz) 50 50
Max. incoming cable capacity mm2 (phase and neutral) 50 50
Max. outgoing cable capacity mm2 25 25
Certification BS EN 61439-3 BS EN 61439-3
IP rating BS EN 60529 (internal) 2XB 2XB
IncomingSwitch disconnector – 100ATerminal block – 100ARCCB’s – 63 or 100A/30mA, 100 or 300mA
Control devicesMay be installed at any outgoing point on the RCD protected or unprotected side
OutgoingMCB’s – B or C curve, 3 - 50ARCBO’s – B curve 45A, 6kA
Dimensions (mm)
Dimensions (mm)
No. of ways
No. of ways
SplitRCCB – 63 or 100A/30mA,100 or 300mA
16
Qwikline ll - dual incomer and multi tariff technical data
Insulated units
Reference numberCir A Cir B Height Width Depth
Dual incomerSQO204 2 4 240 296 127
SQO303 3 3 240 296 127
SQO402 4 2 240 296 127
SQO406 4 6 240 368 127
SQO505 5 5 240 368 127
SQO604 6 4 240 368 127
SQO703 7 3 240 368 127
SQO707 7 7 240 440 127
Metal units
Reference numberCir A Cir B Cir C Height Width Depth
Dual incomerSQOM406 4 6 – 247 378 111
SQOM505 5 5 – 247 378 111
SQOM604 6 4 – 247 378 111
SQOM707 7 7 – 247 450 111
Multi tariffSQOM60501 6 5 1 247 450 111
SQOM70401 7 4 1 247 450 111
Note: Incoming and outgoing devices must be selected separately from the Qwikline ll devices section. One incoming device is required per circuit.
Dimensions (mm)
Dimensions (mm)
No. of ways
No. of ways
IncomingSwitch disconnector – 100ATerminal block – 100ARCCB’s – 63 or 100A/30mA, 100 or 300mA
Control DevicesMay be installed at any outgoing position
OutgoingMCB’s – B or C curve, 3 - 50A, 6kARCBO’s – B curve 6 - 45A, 6kA
Technical dataMetal Insulated
Max. busbar current rating (A) 100 100
Max. operating voltage (V) 240 240
Operating frequency (Hz) 50 50
Max. incoming cable capacity mm2 (phase and neutral) 50 50
Max. outgoing cable capacity mm2 25 25
Certification BS EN 61439-3 BS EN 61439-3
IP rating BS EN 60529 (internal) 2XB 2XB
17
Qwikline ll - devices technical data
Qwikline ll - incoming devices
Referencenumber Description No. of
polesCurrentrating
Operatingvoltage (V)
Max. cablecap. mm2
Standardsapproval
Recommended tightening torque
SQO1100M Switch dis. 2 100A 230/240 50 BS EN 60947-3 3.5 N.m.
SQO1100L Terminal block 2 100A 230/240 50 – 3.5 N.m.
SQOE063030 RCCB 2 63A, 30mA 230/240 35 BS EN 61008 3.5 N.m.
SQOE063100 RCCB 2 63A, 100mA 230/240 35 BS EN 61008 3.5 N.m.
Note: All Qwikline II consumer units are supplied without incoming devices. Any incoming device may be installed at any incoming point, or busbar split in any Qwikline II consumer unit.
Requirements Standard units – 1 incoming device required.Split load units – 2 incoming devices required.
Dual incomer units – 2 incoming devices required.Multi tariff units – 3 incoming devices required.
Qwikline ll - outgoing devicesMiniature circuit breakers (B curve)
Reference number
Currentrating
Operatingvoltage (V)
Breaking cap.(Icn (kA))
Max. cablecap. mm2
Standardsapproval
Recommended tightening torque
SQO103EB6 3A 230/240 6 25 BS EN 60898 2 N.m.
SQO106EB6 6A 230/240 6 25 BS EN 60898 2 N.m.
SQO110EB6 10A 230/240 6 25 BS EN 60898 2 N.m.
SQO116EB6 16A 230/240 6 25 BS EN 60898 2 N.m.
SQO120EB6 20A 230/240 6 25 BS EN 60898 2 N.m.
SQO125EB6 25A 230/240 6 25 BS EN 60898 2 N.m.
SQO132EB6 32A 230/240 6 35 BS EN 60898 3.5 N.m.
SQO140EB6 40A 230/240 6 35 BS EN 60898 3.5 N.m.
SQO150EB6 50A 230/240 6 35 BS EN 60898 3.5 N.m.
SQO163EB6 63A 230/240 6 35 BS EN 60898 3.5 N.m.
Miniature circuit breakers (C curve)
Reference number
Currentrating
Operatingvoltage (V)
Breaking cap.(Icn (kA))
Max. cablecap. mm2
Standardsapproval
Recommended tightening torque
SQO103EC6 3A 230/240 6 25 BS EN 60898 2 N.m.
SQO106EC6 6A 230/240 6 25 BS EN 60898 2 N.m.
SQO110EC6 10A 230/240 6 25 BS EN 60898 2 N.m.
SQO116EC6 16A 230/240 6 25 BS EN 60898 2 N.m.
SQO120EC6 20A 230/240 6 25 BS EN 60898 2 N.m.
SQO125EC6 25A 230/240 6 25 BS EN 60898 2 N.m.
SQO132EC6 32A 230/240 6 35 BS EN 60898 3.5 N.m.
SQO140EC6 40A 230/240 6 35 BS EN 60898 3.5 N.m.
SQO150EC6 50A 230/240 6 35 BS EN 60898 3.5 N.m.
SQO163EC6 63A 230/240 6 35 BS EN 60898 3.5 N.m.
RCBO’s (B curve)
Reference number
Currentrating
Operatingvoltage (V)
Breaking cap.(Icn (kA))
Max. cablecap. mm2
Standardsapproval
Recommended tightening torque
SQOR106B03 6A, 30mA (AC class) 230/240 6 10 BS EN 61009 2 N.m.
SQOR110B03 10A,30mA (AC class) 230/240 6 10 BS EN 61009 2 N.m.
SQOR116B03 16A,30mA (AC class) 230/240 6 10 BS EN 61009 2 N.m.
SQOR120B03 20A,30mA (AC class) 230/240 6 10 BS EN 61009 2 N.m.
SQOR132B03 32A,30mA (AC class) 230/240 6 16 BS EN 61009 2 N.m.
SQOR145B03 45A,30mA (AC class) 230/240 6 16 BS EN 61009 2 N.m.
18
> LoadCentre KQDistribution boards
19
LoadCentre KQ - single phase A type distribution boards - 125A
Split load boards are designed for use with earth protection devices (RCD’s) on the secondary side and provide the user with additional protection for selected units.Notes * 2 incoming devices required for split load units. e.g. Switch and RCCB’s.Secondary incomer is a plug on device - see page 20.All devices are supplied separately.
The split metering board is supplied with 2 meters, an overall switch disconnector and individual switch disconnectors for lighting and power. Meters are direct connected with pulse output.
Standard type (excluding incomers)Referencenumber Number of SP ways
Dimensions (mm)Height Width Depth
SE125A6 6 270 266 127
SE125A8 8 270 321 127
SE125A12 12 270 376 127
SE125A16 16 270 456 127
SE125A24 24 500 376 127
Split load type* (excluding incomers)Referencenumber
Number of ways Dimensions (mm)Unprotected SP Protected RCD Height Width Depth
SE125A4SL6 4 6 270 376 127
SE125A5SL5 5 5 270 376 127
SE125A4SL8 4 8 270 456 127
SE125A6SL6 6 6 270 456 127
Split meter board (including incomers)Referencenumber
Number of ways Dimensions (mm)Lighting Power Height Width Depth
SEA12S12 12 12 484 470 139
Single phase A type distribution boards - 125An Manufactured and tested to BS EN 61439-3n Maximum busbar rating 125An Voltage rating 230/240V ACn External IP3X protection to BS EN 60529n Internal IP2XB protection to BS EN 60529 provided by permanent, non removable, factory fitted barriersn Shielded neutral barsn Cable knockouts on all sides for speed of installationn Earth bar capacity 25mm2
n Neutral bar capacity 25mm2
n Wide range of bolt-on incomers, Plug-On outgoersn All A boards accept DIN control products e.g. contactors, time clocks, in any unused outgoing way without adaptation
20
LoadCentre KQ - single phase A type distribution boards - 125A
Type A LoadCentre KQ+ DIN incoming devicesReferencenumber
Device type
Current rating
Number of poles
Standard approval
Cable capacity mm2
SE125L2 Terminal block 125A 2 – 50
SE125SW2 Switch disconnector 125A 2 BS EN 60947-3 50
SED63032 RCCB 63A, 30mA 2 BS EN 61008 35
SED63102 RCCB 63A, 100mA 2 BS EN 61008 35
SED63302 RCCB 63A, 300mA 2 BS EN 61008 35
SED100032 RCCB 100A, 30mA 2 BS EN 61008 50
SED100102 RCCB 100A, 100mA 2 BS EN 61008 50
Plug on RCCB secondary incomers for split load A boardsReferencenumber
Device type
Current rating
Number of poles
Standard approval
Cable capacity mm2
SQOE063030 RCCB 63A, 30mA 2 BS EN 61008 35
SQOE063100 RCCB 63A, 100mA 2 BS EN 61008 35
SQOE100030 RCCB 100A, 30mA 2 BS EN 61008 50
SQOE100100S RCCB 100A, 100mA TD 2 BS EN 61008 50
SQOE100100 RCCB 100A, 100mA 2 BS EN 61008 50
SQOE100300 RCCB 100A, 300mA 2 BS EN 61008 50
125A A board accessoriesReferencenumber
Device type
SEK Barrel lock and 2 keys new square door catch
SQODNBP Blanking plate (5 poles)
SEPLMCB MCB padlock attachment (pk 10)
SEPLRCBO RCBO padlock attachment (pk 10)
SEPL Padlock
SEAE16 A type DIN rail extension enclosure (16 SP ways available)
SE1100L 100A lug unit single pole
SESDC Replacement door catch
SEBP25 Blank plate 25 x 5
21
LoadCentre KQ - three phase B type distribution boards - 250A
Standard type (excluding incomers)Referencenumber Number of TP ways
Dimensions (mm)Height Width Depth
SE12B250 4 484 470 139
SE18B250 6 484 470 139
SE24B250 8 538 470 139
SE36B250 12 700 470 139
SE48B250 16 808 470 139
SE54B250 18 862 470 139
SE72B250 24 1024 470 139
Split load (excluding incomers)Referencenumber
Number ofTP ways
Referencenumber
Number ofTP ways
SE12B250 4 SE12B250 4
SE18B250 6 SE18B250 6
SE24B250 8 SE24B250 8
SE36B250 12 SE36B250 12
SE48B250 16 SE48B250 16
SE54B250 18 SE54B250 18
SE72B250 24 SE72B250 24
Extra service units 125A (combination of a standard board and DIN rail enclosure)Referencenumber
Number of TPbusbar ways
Referencenumber
Numberof rows
Number of modules
Dimensions (mm)Height Width Depth
SE12B250 4 SE17BES 1 17 270 470 139
SE18B250 6 SE12B2D 2 34 484 470 139
SE24B250 8 SE18B2D 2 34 538 470 139
SE36B250 12 SE36B3D 3 51 700 470 139
SE48B250 16 SE54B4D 4 68 808 470 139
SE54B250 18
SE72B250 24
Three phase B type distribution boards - 250An Manufactured and tested to BS EN 61439-3n Maximum busbar rating 250An Voltage Rating 400/415V ACn External IP3X protection to BS EN 60529n IP2XB finger safe with door and cover removed to BS EN 60529, provided by permanent, non removable, factory fitted barriersn Fully shielded neutral barsn Earth and neutral bar cable capacity 25mm2
n All incoming connections are the same length i.e. 4 pole configurationn Range of integral incomers for all applications including lugs, switches, RCCB’s and MCCB’sn Outgoing MCB’s available up to 63A B, C or D curvesn 18mm wide RCBO available, minimising use of outgoing waysn Plug-On outgoers for speed of installation and guaranteed connectionn All B boards accept DIN control products (timers, contactors) in any unused outgoing way without adaptationn Control wiring cable way integrated to moulding
} {+
} {+
Split load joining kit for mechanical connection SEJK. 63A tapoff to feed protected board (including joining kit) SE63SLK.
Extra service units are designed for application using numerous control products and RCCB’s.These units provide a professional finish while economising on ease and speed of installation.
22
LoadCentre KQ - three phase B type distribution boards
125A boards are supplied with a switch disconnector2 x PM750 meters included (pulsed and ModBus output)
250A boards require a switch disconnector to be added2 x multi function meter included (pulsed and ModBus output)
Split metering board 125AReferencenumber
Number of TP waysSection 1 Section 2
RatingA
Dimensions (mm)Height Width Depth
SEB36S24125 12 8 125 1290 470 139
SEB42S18125 14 6 125 1290 470 139
SEB48S12125 16 4 125 1290 470 139
Split metering board 250AReferencenumber
Number of TP waysSection 1 Section 2
RatingA
Dimensions (mm)Height Width Depth
SEB36S24250 12 8 250 1290 470 139
SEB42S18250 14 6 250 1290 470 139
SEB48S12250 16 4 250 1290 470 139
L <25mmd <10mmØ >8mm
250A type B LoadCentre KQ incoming devicesReferencenumber
Device type
Current rating
Number of poles
Standard approval
Cable capacity mm2
SE250L4P Terminal block 250A 4 – 185
SE160SW3L Switch disconnector 160A 3+N BS EN 60947-3 95
SE200SW3L Switch disconnector 200A 3+N BS EN 60947-3 185
SE250SW3L Switch disconnector 250A 3+N BS EN 60947-3 185
SE160SW4 Switch disconnector 160A 4 BS EN 60947-3 95
SE200SW4 Switch disconnector 200A 4 BS EN 60947-3 185
SE250SW4 Switch disconnector 250A 4 BS EN 60947-3 185
SE100MCCB3L MCCB 100A 3+N BS EN 60947-2 95
SE160MCCB3L MCCB 160A 3+N BS EN 60947-2 95
SE200MCCB3L MCCB 200A 3+N BS EN 60947-2 185
SE250MCCB3L MCCB 250A 3+N BS EN 60947-2 185
SE160RCD RCCB 160A Adjustable30mA - 10A
4 BS EN 61008 95
125A type B LoadCentre KQ incoming devicesReferencenumber
Device type
Current rating
Number of poles
Standard approval
Cable capacity mm2
SE125L4 Terminal block 125A 4 – 50
SE125SW4 Switch disconnector 125A 4 BS EN 60947-3 50
SE125SW3L Switch disconnector 125A 3+N lug BS EN 60947-3 50
SED80034 RCCB 80A, 30mA 4 BS EN 61008 35
SED100304 RCCB 100A, 300mA 4 BS EN 61008 50
SED100304S RCCB 100A, 300mA TD 4 BS EN 61008 50
SECSW100 Contactor + switch 100A 4 BS EN 60439 50
Note For a wider range of RCCB incomers see the RSD offer on page 25
Note Supplied with 400mm extension box
Metering kitReferencenumber Description
SE250MET Multi function metering kit for LoadCentre KQ 3 phase B type distribution boards Components: Multi function meter provides V, A, Power factor kW/h, kVA/h. Three current transformers. Three single pole MCB’sVoltage rating: 415V nominal, 455V maximum. 3 phase 4 wire 50-60 HzOutput: Pulse output contact is standard + ModBus
23
B board accessoriesReferencenumber
Device type
SESJK Side joining kit
SEJK Top/bottom joining kit
SE63SLK 63A Top off or split load
SEK Barrel lock and 2 keys for catch
SEK33 Spare keys for above
W29370 MCCB locking attachment
SE125SPP 125A single phasing kit for use with RCD and switch incomers
SE250SPP 250A single phasing kit
SQODNBP Blanking plate (5 poles)
SEPLMCB MCB padlock attachment (pk 10)
SEPLRCBO RCBO padlock attachment (pk 10)
SEPL Padlock
WALLET Circuit directory and wallet (pack of 10)
SEPD Padlocking door kit
SEBES Plain extension box
SE1100L 100A lug unit single pole
SEGPKO Spare gland plate with knockouts
SEGP Spare gland plate
SECE12T Clean earth 12 terminals
SECE24T Clean earth 24 terminals
SE72BL Spare way label 72 ways
SEEXGP Spare gland plate for extension box
SESDC Spare door catch
SEBNC Neutral terminal cover
SEBFCF Spare cover fixing (24)
SEBEK1 Extra earth bar 14 hole
SEBEK2 Extra earth bar 20 hole
SEBEK3 Extra earth bar 26 hole
LoadCentre KQ - three phase B type distribution boards
24
LoadCentre KQ - KQ miniature circuit breakers (MCB’s)
Type B (magnetic setting 3-5 in)For resistive and light reactive loads, e.g. heating, incandescent lighting etc Reference numbers Current
rating (Icn*)Cable capacity mm21 pole 2 pole 3 pole
SE10B103 – – 3A 25SE10B106 – – 6A 25SE10B110 – – 10A 25SE10B116 – – 16A 25SE10B120 – – 20A 25SE10B125 – – 25A 25SE10B132 – – 32A 35SE10B140 – – 40A 35SE10B150 – – 50A 35SE10B163 – – 63A 35
Type C (magnetic setting 5-10 in)For moderately light reactive loads, e.g. fluorescent lighting Reference numbers Current
rating (Icn*)Cable capacity mm21 pole 2 pole 3 pole
SE10C106 SE10C206 SE10C306 6A 25SE10C110 SE10C210 SE10C310 10A 25SE10C116 SE10C216 SE10C316 16A 25SE10C120 SE10C220 SE10C320 20A 25SE10C125 SE10C225 SE10C325 25A 25SE10C132 SE10C232 SE10C332 32A 35SE10C140 SE10C240 SE10C340 40A 35SE10C150 SE10C250 SE10C350 50A 35SE10C163 SE10C263 SE10C363 63A 35
Type D (magnetic setting 10-14 in)For highly reactive loads, e.g. motors, pumps and transformers Reference numbers Current
rating (Icn*)Cable capacity mm21 pole 2 pole 3 pole
SE10D106 SE10D206 SE10D306 6A 25SE10D110 SE10D210 SE10D310 10A 25SE10D116 SE10D216 SE10D316 16A 25SE10D120 SE10D220 SE10D320 20A 25SE10D125 SE10D225 SE10D325 25A 25SE10D132 SE10D232 SE10D332 32A 35SE10D140 SE10D240 SE10D340 40A 35SE10D150 SE10D250 SE10D350 50A 35SE10D163 SE10D263 SE10D363 63A 35
DIN rail mounted 80/100A MCBSuitable for use in extension enclosures or extra service unitsReference number Description Terminal capacity Modular size
KQ10C3100 MCB 3P 100A Type C 50 4.5KQ10C380 MCB 3P 80A Type C 50 4.5
KQ miniature circuit breakers (MCB’s)n Manufactured and tested to BS EN 60898n 10kA breaking capacity 15kA to BS EN 60947-2n Let through energy classification of 3 (lowest let through energy giving best cable protection classification)n Positive contact indication (guaranteed on/off indication)n Trip free mechanism operates even when the toggle is locked onn Lockable in the ON or OFF positionn Speed of connection of Plug-On devices - guaranteed connection Plug-On devicesn For use in LoadCentre KQ A and B boards
Must be used with SE17BES enclosure and 3 x SE1100L.
25
LoadCentre KQ - residual current circuit breakers (RCBO’s)
AplicationsRCBO’s are available with various earth leakage sensitivities to suit numerous applications including 10mA devices for protection of sensitive machine/equipment, 30mA devices which are generally used for personnel protection and 100mA for meeting high earth loop impedance levels.
RCBO’s should be carefully selected for the relevant application.
Residual current circuit breakers (RCBO’s)n Manufactured and tested to BS EN 61009n 10kA breaking capacityn Let through energy classification of 3 (lowest let through energy giving best cable protection classification)n Positive contact indication on toggle (guaranteed on/off indication)n Trip free MCB mechanismn Lockable in the ON or OFF positionn Automatic trip on loss of neutraln Automatic protection against reverse polarityn Type B and C characteristicsn Operating voltage 150 - 230Vacn 6 - 45A; 10, 30 and 100mA sensitivitiesn AC class sensitivityn For use in KQ LoadCentre A and B boardsn One single pole way occupied in a distribution board ideal for retrofitting earth fault protectionn Cable capacity 16mm2
n Speed of connection of Plug-On devicesn Assured system integrity, no other devices fit KQ boards
Residual current circuit breakersReferencenumber
Current rating
Tripping curve Sensitivity Cable capacity
mm2
SEE106B03 6A B 30mA 16
SEE110B03 10A B 30mA 16
SEE116B03 16A B 30mA 16
SEE120B03 20A B 30mA 16
SEE125B03 25A B 30mA 16
SEE132B03 32A B 30mA 16
SEE140B03 40A B 30mA 16
SEE145B03 45A B 30mA 16
SEE106C01 6A C 10mA 16
SEE110C01 10A C 10mA 16
SEE116C01 16A C 10mA 16
SEE120C01 20A C 10mA 16
SEE125C01 25A C 10mA 16
SEE132C01 32A C 10mA 16
SEE140C01 40A C 10mA 16
SEE145C01 45A C 10mA 16
SEE106C03 6A C 30mA 16
SEE110C03 10A C 30mA 16
SEE116C03 16A C 30mA 16
SEE120C03 20A C 30mA 16
SEE125C03 25A C 30mA 16
SEE132C03 32A C 30mA 16
SEE140C03 40A C 30mA 16
SEE145C03 45A C 30mA 16
SEE106C10 6A C 100mA 16
SEE110C10 10A C 100mA 16
SEE116C10 16A C 100mA 16
SEE120C10 20A C 100mA 16
SEE125C10 25A C 100mA 16
SEE132C10 32A C 100mA 16
SEE140C10 40A C 100mA 16
SEE145C10 45A C 100mA 16
26
LoadCentre KQ - residual current circuit breakers (RCCB’s)
Residual current circuit breakers (RCCB’s)All residual current circuit breakers are suitable for use as main incomers in LoadCentre KQ distribution boards.n Comply with BS EN 61008. Specification for residual current operated circuit breakersn Rated voltage 240/415V AC 50/60 Hzn Test button enables RCCB to be tested periodicallyn 30mA device suitable for use as additional protection on final sub circuits e.g. equipment outside equipotential zone or items requiring 2/4 pole protection i.e. switched neutral applications
Residual current circuit breakersReferencenumber Description
Cable capacity mm2
Dimensions (mm) Weight (Kg)Height Width Depth
SED25032 25A RCCB 30mA trip 2 pole 35 81 36 75 0.227
SED25302 25A RCCB 300mA trip 2 pole 35 81 36 75 0.227
SED40032 40A RCCB 30mA trip 2 pole 3 35 81 36 75 0.227
SED40102 40A RCCB 100mA trip 2 pole 35 81 36 75 0.227
SED40302 40A RCCB 300mA trip 2 pole 35 81 36 75 0.227
SED63032 63A RCCB 30mA trip 2 pole 3 35 81 36 75 0.227
SED63102 63A RCCB 100mA trip 2 pole 35 81 36 75 0.227
SED63302 63A RCCB 300mA trip 2 pole 35 81 36 75 0.227
SED80032 80A RCCB 30mA trip 2 pole 50 81 36 75 0.227
SED100032 100A RCCB 30mA trip 2 pole 50 81 36 75 0.227
SED100102 100A RCCB 100mA trip 2 pole 50 81 36 75 0.227
SED25034 25A RCCB 30mA trip 4 pole 35 81 72 75 0.428
SED25104 25A RCCB 100mA trip 4 pole 35 81 72 75 0.428
SED25304 25A RCCB 300mA trip 4 pole 35 81 72 75 0.428
SED40034 40A RCCB 30mA trip 4 pole 35 81 72 75 0.428
SED40104 40A RCCB 100mA trip 4 pole 35 81 72 75 0.428
SED40304 40A RCCB 300mA trip 4 pole 35 81 72 75 0.428
SED63034 63A RCCB 30mA trip 4 pole 35 81 72 75 0.428
SED63104 63A RCCB 100mA trip 4 pole 35 81 72 75 0.428
SED63304 63A RCCB 300mA trip 4 pole 35 81 72 75 0.428
SED80034 80A RCCB 30mA trip 4 pole 35 81 72 75 0.500
SED100304 100A RCCB 300mA trip 4 pole 50 81 72 75 0.500
SED100304S 100A RCCB 300mA trip 4 pole + TD 50 81 72 75 0.500
Individual RCCB insulated enclosureReferencenumber Description
Dimensions (mm) Weight (Kg)Height Width Depth
RSD4IP54 4 x 18mm module IP54 protection 200 110 112 0.35
RSD insulated enclosures are also suitable for any DIN rail mounted product including time clocks, timers, contactors, switches and relays.
27
LoadCentre KQ - extension enclosures
Extension enclosuresLoadCentre KQ enclosures are available for applications where matching extension boxes are required to house system extensions or stand alone control systems.There are two configurations, plain enclosures with door, enclosures with DIN rail, door and front cover assembly.
Steel enclosures with plain cover and doorReferencenumber
Dimensions (mm)Height Width Depth
SE12BCD 484 470 139
SE18BCD 538 470 139
SE36BCD 700 470 139
SE54BCD 808 470 139
Steel enclosures with DIN rails and a front cover assembly and doorReferencenumber
Numberof rows
Total numberof SP modules
Dimensions (mm)Height Width Depth
SE12B2D 2 34 484 470 139
SE18B2D 2 34 538 470 139
SE36B3D 3 51 700 470 139
SE54B4D 4 68 808 470 139
Steel enclosure with 1 row of DIN rails and a front cover assembly and doorReferencenumber
Numberof rows
Total numberof SP modules
Dimensions (mm)Height Width Depth
SE172BES 1 17 270 470 139
Steel enclosureReferencenumber
Numberof rows
Total numberof SP modules
Dimensions (mm)Height Width Depth
SEBES – – 270 470 124
28
> PanelboardsI-Line MCCB
28
29
Panelboards - I-Line MCCB panelboards Size 1 250A
Step 1 Select panelboard required
Description ModulesReference number250A
6 triple pole outgoing ways 18 MP25061
12 triple pole outgoing ways 36 MP250121
Step 2 Select incoming device250A Reference number
250A 36kA triple pole MCCB CNXAE34250
250A 50kA triple pole MCCB CHXAE34250
100A automatic switch disconnector (isolator) CNXAE34000S10
160A automatic switch disconnector (isolator) CNAXE34000S15
250A automatic switch disconnector (isolator) CNAXE34000S25
225A plug on lug unit SL225
Step 3 Select outgoing devicesSingle and double pole MCCB’s are phase dedicated. To obtain correct reference add suffix as below example: 40A SP MCCB to fit L3 will be SFA1040C
Size 1 250/400A panelboardsn Single sided to give best possible space utilisationn Incomers can be mounted at top or bottom of the panelboardn Ample cabling spacen L-Line Busbar Systemn Degree of protection IP3Xn Hinged lift off cable way covern MCCB separation to form 3b Type 2 BS EN 60439-1n Fully rated earth and neutral barsn Simple orderingn Removable top and bottom gland platesn Busbar rating 50ka for 1s
MCCB
16-100A 25kA Single Pole (1 Mod) Double Pole (2 Mod)
L1 L2 L3 L1/L2 L2/L3 L1/L3
Suffix Suffix
16A SFA1016 SFA2016
20A SFA1020 SFA2020
32A SFA1032 SFA2032
40A SFA1040 A B C SFA2040 AB BC AC
50A SFA1050 SFA2050
63A SFA1063 SFA2063
80A SFA1080 SFA2080
100A SFA1100 SFA2100
30
Panelboards - I-Line MCCB panelboards Size 1 250A
Step 4 Select meteringThe I-Line Panelboard product range has being enhanced to include the facility to meter incoming and outgoing circuits. This enables contractors to easily and simply meet the requirements of Part L2a of the Building Regulations. These metering kits allow great flexibility in the choice of meter and also in the configuration of the boards.
Incoming metering This metering kit is for the incoming supply to the board. It comprises an extension box that can be fitted to the top or the bottom of a standard board. This box contains a three-phase block current transformer, fuses for the voltage supply and a PM750 multi-function meter. Because the main incoming cables pass through this enclosure it is not suitable for a retrofit. The kit comes complete: no other parts are required to install this metering kit.
Reference number Incoming Metering
MPME2501 250A top/bottom metering extension box
Step 3 Select outgoing devices cont.Triple pole (3 mods) Additional
tunnelterminals
Acceptablecablesize
25kA 36kA 50kA Reference No.
16A CDXAE34016 CNXAE34016 CHXAE34016
25A CDXAE34025 CNXAE34025 CHXAE34025
32A CDXAE34032 CNXAE34032 CHXAE34032
40A CDXAE34040 CNXAE34040 CHXAE34040 LV42922 1.5-95mm
50A CDXAE34050 CNXAE34050 CHXAE34050
63A CDXAE34063 CNXAE34063 CHXAE34063
80A CDXAE34080 CNXAE34080 CHXAE34080
100A CDXAE34100 CNXAE34100 CHXAE34100
125A CNXAE34125 CHXAE34125
160A CNXAE34160 CHXAE34160
200A CNXAE34200 CHXAE34200 LV429259 95-185mm
250A CNXAE34250 CHXAE34250 LV429259
160A electronic CNXAE34160E20 LV429242 1.5-95mm
250A electronic CNXAE250E20 LV425252 95-185mm
31
Panelboards - I-Line MCCB panelboards Size 1 250A
Step 5 Select accessoriesPanelboard MP25061 MP250121
Blanking plates for all unused ways
Single pole HNM1BL HNM1BL
Triple pole HNM4BL HNM4BL
Side extension box
508mm wide EXMS20411 EXMS22051
Top / bottom extension box
226mm high EXS91 EXS91
MCCB Incomer padlocking device
250A 29370 29370
Door lock QOKS1 QOKS1
2 Spare keys KQK33 KQK33
Terminal shields x 2 See page 18
Plug-on metering kit for incoming supply - occupies 4 modules
Analogue, voltmeter & ammeter
MP250INS MP250INS
* Digital, multi function meter
MP250kW MP250kW
Weight in kg 46 76
Overall dimensions H x W x D
1041x508x184 1727x508x184
Fixing centres 800 1486
* See page 44 for outgoing metering
32
Panelboards - I-Line MCCB panelboards Size 1 400A
Step 1 Select panelboard required
Description ModulesReference number400A
4 triple pole outgoing ways 12 MP40041
7 triple pole outgoing ways 21 MP40071
12 triple pole outgoing ways 36 MP400121
Size 1 400A panelboardsn Single sided to give best possible space utilisationn Incomers cabe mounted at top or bottom of the panelboardn Ample cabling spacen I-Line busbarn Degree of protection IP3Xn Hinged lift off cable way covern MCCB separation to form 3b Type 2 BS EN 60439-1n Fully rated earth and neutral barsn Simple orderingn Removable top and bottom gland platesn Busbar rating 50ka for 1s
Step 2 Select incoming device250A Reference number
250A 36kA triple pole MCCB CNXAE34250
250A 50kA triple pole MCCB CHAXE34250
100A automatic switch disconnector (isolator) CNAXE34000S10
160A automatic switch disconnector (isolator) CNAXE34000S15
250A automatic switch disconnector (isolator) CNAXE34000S25
225A plug on lug unit SL225
400A*
400A 36kA triple pole MCCB SLA3400
400A automatic switch disconnector (isolator) SLA3000M
*Trim, required when 250A incomer fitted TKA4, TKA7, TKA12
Step 3 Select outgoing devicesSingle and double pole MCCB’s are phase dedicated. To obtain correct reference add suffix as below example: 40A SP MCCB to fit L3 will be SFA1040C
MCCB
16-100A 25kA Single Pole (1 Mod) Double Pole (2 Mod)
L1 L2 L3 L1/L2 L2/L3 L1/L3
Suffix Suffix
16A SFA1016 SFA2016
20A SFA1020 SFA2020
32A SFA1032 SFA2032
40A SFA1040 A B C SFA2040 AB BC AC
50A SFA1050 SFA2050
63A SFA1063 SFA2063
80A SFA1080 SFA2080
100A SFA1100 SFA2100
33
Panelboards - I-Line MCCB panelboards Size 1 400A
Step 3 Select outgoing devices cont.Triple pole (3 mods) Additional
tunnel terminalsAcceptablecable size
25kA 36kA 50kA Reference No.
16A CDXAE34016 CNXAE34016 CHXAE34016
25A CDXAE34025 CNXAE34025 CHXAE34025
32A CDXAE34032 CNXAE34032 CHXAE34032
40A CDXAE34040 CNXAE34040 CHXAE34040 LV429242 1.5-95mm
50A CDXAE34050 CNXAE34050 CHXAE34050
63A CDXAE34063 CNXAE34063 CHXAE34063
80A CDXAE34080 CNXAE34080 CHXAE34080
100A CDXAE34100 CNXAE34100 CHXAE34100
125A CNXAE34125 CHXAE34125
160A CNXAE34160 CHXAE34160
200A CNXAE34200 CHXAE34200 LV429259 95-185mm
250A CNXAE34250 CHXAE34250 LV429259
160A electronic CNXAE34160E20 LV429242 1.5-95mm
250A electronic CNXAE34250E20 LV429259 95-185mm
Step 4 Select meteringThe I-Line Panelboard product range has being enhanced to include the facility to meter incoming and outgoing circuits. This enables contractors to easily and simply meet the requirements of Part L2a of the Building Regulations. These metering kits allow great flexibility in the choice of meter and also in the configuration of the boards.
Outgoing metering A standard board can be adapted to meter the incoming supply and some or all of the outgoing circuits by the addition of three components. These components are:
A. Select metering kit 1 Metering kit. This contains a replacement wireway door with 96 sq cutouts for the number of outgoing ways of the board plus one. This additional cutout is to meter the incoming supply as required. Blanking plates are supplied for unused meter positions. One door kit per board.
Size 1 400AReference number
MPMK104 4 way I-Line metering kit
MPMK107 7 way I-Line metering kit
MPMK112 12 way I-Line metering kit
B. Select metering CT set for each outgoing MCCB to be monitored2 Current transformer kit. One kit for each circuit to be measured. The kit will comprise a three phase CT block, mounting plate and cable loom. The CT blocks fit to the breakers. The CT size and ratio matches the breaker.
Reference number CT ratio
MPCT125 C frame breaker 125/5
MPCT150 C frame breaker 150/5
MPCT250 C frame breaker 250/5
C. Select PowerLogic meters for each circuit to be measured
Reference number
PM700 Multi function PowerMeter
PM700P Multi function PowerMeter with pulse outputs
PM710 Multi function PowerMeter with Modbus RS485 output
PM750 Same functions as the PM710, plus two digital inputs, one digital output, alarms and signed power factor. The PM750 digital output can be simply configured as a kWh pulse output
34
Panelboards - I-Line MCCB panelboards Size 1 400A
Step 5 Select accessoriesPanelboard MP40041 MP40071 MP400121
Blanking plates for all unused ways
Single pole HNM1BL HNM1BL HNM1BL
Triple pole HNM4BL HNM4BL HNM4BL
Blanking plates for every MCCB way when one or more PF devices fitted
Single pole HNF1BL HNF1BL HNF1BL
Triple pole HNF4BL HNF4BL HNF4BL
Trim, required when 250A incomer fitted TKA4 TKA7 TKA12
Side extension box
508mm wide
550mm wide EXMS827 EXMS1170 EXMS1742
Top / bottom extension box
226mm high
379mm high EXS151 EXS151 EXS151
MCCB Incomer padlocking device
250A 29370 29370 29370
400A HPALM HPALM HPALM
Door lock QOKS1 QOKS1 QOKS1
2 Spare keys KQK33 KQK33 KQK33
Terminal shields x 2 See page 42
Plug-on metering kit for incoming supply - occupies 4 modules
Analogue, voltmeter & ammeter MP400INS MP400INS MP400INS
* Digital, multi function meter MP400kW MP400kW MP400kW
Weight in kg 44 74 100
Overall dimensions H x W x D 827x680x258 1170x680x258 1742x680x258
Fixing centres 533 876 1448
* See page 44 for outgoing metering
35
Panelboards - I-Line MCCB panelboards Size 2 630A
Step 1 Select panelboard required
Description ModulesReference number630A
6 triple pole outgoing ways 9+9 MP63062
10 triple pole outgoing ways 15+15 MP630102
14 triple pole outgoing ways 21+21 MP630142
18 triple pole outgoing ways 27+27 MP630182
Size 2 630A panelboardsn Degree of protection IP3Xn Door lock fitted as standardn Ample cabling spacen I-Line busbarn Removable neutral linkn Hinged lift off cable way coversn MCCB separation to form 3b Type 2 BS EN 60439-1n Fully rated earth and neutral barsn Removable top and bottom gland platesn Simple orderingn Maximum outgoers 250An Busbar rating 50ka for 1s
Step 2 Select incoming deviceReference number
250A 36kA triple pole MCCB SLA3250
400A 36kA triple pole MCCB SLA3400
400A automatic switch disconnector (isolator) SLA3000M
600A 50kA triple pole MCCB PJA36060CU31A
600A automatic switch disconnector (isolator) PJA36000S60
630A main lugs kit ML630
Step 3 Select outgoing devicesSingle and double pole MCCB ’s are phase dedicated. To obtain correct reference add suffix as below example: 40A SP MCCB to fit L3 will be SFA1040CC
MCCB
16-100A 25kA Single Pole (1 Mod) Double Pole (2 Mod)
L1 L2 L3 L1/L2 L2/L3 L1/L3
Suffix Suffix
16A SFA1016 SFA2016
20A SFA1020 SFA2020
32A SFA1032 SFA2032
40A SFA1040 A B C SFA2040 AB BC AC
50A SFA1050 SFA2050
63A SFA1063 SFA2063
80A SFA1080 SFA2080
100A SFA1100 SFA2100
36
Panelboards - I-Line MCCB panelboards Size 2 630A
Step 3 Select outgoing devices cont.Triple pole (3 mods) Additional
tunnelterminals
Acceptablecablesize
25kA 36kA 50kA Reference No.
16A CDXAE34016 CNXAE34016 CHXAE34016
25A CDXAE34025 CNXAE34025 CHXAE34025
32A CDXAE34032 CNXAE34032 CHXAE34032
40A CDXAE34040 CNXAE34040 CHXAE34040 LV42922 1.5-95mm
50A CDXAE34050 CNXAE34050 CHXAE34050
63A CDXAE34063 CNXAE34063 CHXAE34063
80A CDXAE34080 CNXAE34080 CHXAE34080
100A CDXAE34100 CNXAE34100 CHXAE34100
125A CNXAE34125 CHXAE34125
160A CNXAE34160 CHXAE34160
200A CNXAE34200 CHXAE34200 LV429259 95-185mm
250A CNXAE34250 CHXAE34250 LV429259
160A electronic CNXAE34160E20 LV429242 1.5-95mm
250A electronic CNXAE34250E20 LV425252 95-185mm
37
Panelboards - I-Line MCCB panelboards Size 2 630A
Step 4 Select meteringThe I-Line Panelboard product range has being enhanced to include the facility to meter incoming and outgoing circuits. This enables contractors to easily and simply meet the requirements of Part L2a of the Building Regulations. These metering kits allow great flexibility in the choice of meter and also in the configuration of the boards.
A standard board can be adapted to meter the incoming supply and some or all of the outgoing circuits by the addition of three components. These components are:
A. Select metering kit 1 Metering kit. This contains a replacement wireway door with 96 sq cutouts for the number of outgoing ways of the board plus one. This additional cutout is to meter the incoming supply as required. Blanking plates are supplied for unused meter positions. One door kit per board.
Size 2 630AReference number
MPMK206 6 way I-Line metering kit
MPMK210 10 way I-Line metering kit
MPMK214 14 way I-Line metering kit
MPMK218 18 way I-Line metering kit
B. Select metering CT set for each outgoing MCCB to be monitored2 Current transformer kit. One kit for each circuit to be measured. The kit will comprise a three phase CT block, mounting plate and cable loom. The CT blocks fit to the breakers. The CT size and ratio matches the breaker.
Reference number CT ratio
MPCT125 C frame breaker 125/5
MPCT150 C frame breaker 150/5
MPCT250 C frame breaker 250/5
MPCT400 L frame breaker 400/5
MPCT600 M & P frame breakers 600/5
C. Select PowerLogic meters for each circuit to be measured
Reference number
PM700 Multi function PowerMeter
PM700P Multi function PowerMeter with pulse outputs
PM710 Multi function PowerMeter with Modbus RS485 output
PM750 Same functions as the PM710, plus two digital inputs, one digital output, alarms and signed power factor. The PM750 digital output can be simply configured as a kWh pulse output
38
Panelboards - I-Line MCCB panelboards Size 2 630A
Step 5 Select accessoriesPanelboard MP63062 MP630102 MP630142 MP630182
Blanking plates for all unused ways
Single pole HNM1BL HNM1BL HNM1BL HNM1BL
Triple pole HNM4BL HNM4BL HNM4BL HNM4BL
Side extension box 550mm wide EXMS53 EXMS62 EXMS71 EXMS80
Top / bottom extension box 226mm high EXS29 EXS29 EXS29 EXS29
Corner unit, to complete enclosure when top/bottom and side extension are both fitted
MSIL636 MSIL636 MSIL636 MSIL636
Door lock
2 Spare keys KQK33 KQK33 KQK33 KQK33
Terminal shields x 2 See page 42
Integral metering kit for incoming supply
Analogue, voltmeter & ammeter
400A 400INSKN 400INSKN 400INSKN 400INSKN
630A 600INSKN 600INSKN 600INSKN 600INSKN
* Digital, multi function meter
400A 400kW 400kW 400kW 400kW
630A 630kW 630kW 630kW 630kW
Weight in kg 112 128 145 164
Overall dimensions H x W x D 1350x1100x258 1579x1100x258 1807x1100x258 2036x1100x258
* See page 44 for outgoing metering
39
Panelboards 800A to 1600A Please consult usTel 0870 608 8 608
40
Panelboards - I-Line MCCB panelboards Panelboard accessories
Reference number
1 module way: HNM1BL pack quantity 1
3 module way: HNM4BL pack quantity 1
Reference number
Door lock QOKS1 supplied with 2 keys.
Panelboard size 2 is supplied with a door lock as standard. If replacement locks are required, order reference QOKSB. Set of 2 spare keysKQK 33
Blanking platesSuitable for all sizes of panelboard, blanking plates must be fitted in all unoccupied outgoing ways to maintain appropriate busbar shrouding.
Panelboards are supplied without blanking plates.
Door lockAll keys are identical.For size 1 panelboard, field installable.
Side extension boxesSupplied with hinged door, side extension boxes may be used to provide additional wiring space or fitting of control equipment or Qwikline II MCB distribution boards.
Side extension boxes can be fitted to either side of the panelboard and may be coupled together to form larger units.
Box width250A boards: 508mm. 400A, 630A boards: 550mm.
Top/bottom extension boxesSupplied with a flat front plate the extension box provides additional cable spreading space.
Box heights250A: 226mm. 400A: 380mm.630A: 226mm.
Corner units are available to ‘square off’ a board when a side and a top/bottom extension box are fitted.
41
Panelboards - I-Line MCCB panelboards Panelboard accessories
Termination barsSolid brass terminal bars provide tunnel terminals. Main neutral and earth bars are pre-drilled to accept the termination bars indicated. Bars suitable for size 1 and 2.
MCCB locking devicesProvide facilities for padlocking MCCB’s.
Reference number Number of ways Conductor size
NE916 9 25
NE1816 18 25
NE950 9 50
NE7150 7 150
NE13150 13 150
Frame Reference number Facility Padlocks
SFA HPAFK On/Off 1
C 3 pole W29370 Off 3
SLA HPALM Off 1
SLA HPAXLM* Off 1
PJA 44936 Off 1
* Use with handle extension
42
Panelboards - I-Line MCCB panelboards MCCB accessories
Cable clamp terminalsTriple pole CDX, CNX and CHX MCCB’s are supplied with bolt connections. Field fitted terminals.
Crimp cable lugsSpecial lugs for fitting oversize cables to CD, CN and CH MCCB’s.
Handle extensionFor use in providing extra leverage when operating larger frame I-Line MCCB’s.
Terminal extension pads3 plated copper pads to which crimp type lugs may be fastened (unshrouded).
Reference number
16- 160A LV429242 set of 3 1.5 - 95mm2
200- 250A LV429259 set of 3 95 - 185mm2
Reference number
LV429252 set of 3 120mm2 Copper
LV429253 set of 3 150mm2 Copper
LV429254 set of 3 185mm2 Copper
LV429504 set of 3 150mm2 Aluminium
LV429506 set of 3 185mm2 Aluminium
Required for oversized cables only.
Terminal shieldsReference number Quantity
CDX, CNX and CHX short (15mm) LV429515 1
CDX, CNX and CHX long (80mm) LV429517X 1
SLA LCA1 2
SMA MCA1 2
SFA single pole FTS 1
Use short terminal shields with tunnel terminals.Use long terminal shields with crimp terminals.
Reference number
SLA frame AHEXLI
SM MAHEX
PJA frame 46996
Reference number
C frame LV431563
SLA frame LATK3
PJA PJATK3
The pads require an air gap of 25mm between them and adjacent MCCB’s the use of an HNM1BL either side of the MCCB will provide the necessary spacing.
43
Panelboards - I-Line MCCB panelboards MCCB accessories
Shunt trip (ST)Energisation of shunt trip coil will initiate MCCB tripping.
Under voltage release (UVR)The coil must be energised before the MCCB can be switched on.
Auxiliary switches (aux)Change over contacts indicate MCCB contact position. For CDX, CNX and CHX may be used as an alarm switch.
Lug unitTo sub-feed power from, or into the busbar stack. Current rating of plug-on lug must be equal to or greater than the incoming protective device.
Order referencesDescription CDX-CNX-CHX SLA
Shunt trip 110/130V 50Hz LV429386 –
Shunt trip 200/240V 50Hz LV429387 –
Shunt trip 120/240V 50Hz – LA11021
Shunt trip 277/480V 50Hz – LA11037
Shunt trip 24V dc LV429390 LA11027
Under voltage release 110/130V 50Hz LV429406 LA11121
Under voltage release 200/240V 50Hz LV429407 LA11124
Under voltage release 24V dc LV429410 LA11127
Auxiliary switch 1 change over contact LV429450 LA11212
Auxiliary switch 2 change over contact LV429450 x 2 LA11352
CDX, CNX and CHX Connection terminals accept wires up to 1.5mm2
SL, Supplied with 1mm2 flying leads
Field installable.
CDX, CNX and CHX Connection terminals accept wires up to 1.5mm2
SL, Supplied with 1mm2 flying leads
Field installable.
CDX, CNX and CHX Connection terminals accept wires up to 1.5mm2
SL, Supplied with 1mm2 flying leads
Field installable.
Reference number Rating Modules Terminal capacity mm2
SL100 100A 3 50
SL225 225A 3 185
SL400 400A 4 300
SL800 800A 6 3 x 240
44
Panelboards - I-Line MCCB panelboards Metering facilities
Metering facilitiesThe I-Line Panelboard product range has being enhanced to include the facility to meter incoming and outgoing circuits. This enables contractors to easily and simply meet the requirements of Part L2a of the Building Regulations. These metering kits allow great flexibility in the choice of meter and also in the configuration of the boards. The metering arrangement varies depending on the size of board.
For the Size 1 250A board there is an extension box which may be fitted to the top or bottom of a board to meter the incoming supply.
For Size 1 400A, Size 2 and Size 3 boards components are provided to meter some or all outgoing ways and/or the incoming supply.
Currently most boards have incoming metering kits. These new kits may be used as well as or instead of these existing arrangements.
Size 1 250A boardsThis metering kit is for the incoming supply to the board. It comprises an extension box that can be fitted to the top or the bottom of a standard board. This box contains a three-phase block current transformer, fuses for the voltage supply and a PM700P multi-function meter. Because the main incoming cables pass through this enclosure it is not suitable for a retrofit. The kit comes complete: no other parts are required to install this metering kit. Size 1 (250A)Reference number MPME2501 250A top/bottom metering extension box Size 1 (400A), Size 2 and PanelboardsA standard board can be adapted to meter the incoming supply and some or all of the outgoing circuits by the addition of three components.
These components are1 Metering kit. This contains a replacement wireway door with 96 sq cutouts for the number of outgoing ways of the board plus one. This additional cutout is to meter the incoming supply as required. Blanking plates are supplied for unused meter positions. One door kit per board.2 Current transformer kit. One kit for each circuit to be measured. The kit will comprise a three phase CT block, mounting plate and cable loom. The CT blocks fit to the breakers. The CT size and ratio matches the breaker. 3 The multi-function meter for each circuit to be measured. The meter is selected from the Schneider Electric Power Meter range. See below for details.
Size 1 400AReference number No. of Meters
MPMK104 4 way I-Line metering kit 5
MPMK107 7 way I-Line metering kit 8
MPMK112 12 way I-Line metering kit 13
Size 2 630AReference number No. of Meters
MPMK206 6 way I-Line metering kit 7
MPMK210 10 way I-Line metering kit 11
MPMK214 14 way I-Line metering kit 15
MPMK218 18 way I-Line metering kit 19
45
Panelboards - I-Line MCCB panelboards Metering facilities
Outgoing Metering CT set for each MCCB to be monitoredReference number CT ratio
MPCT125 C frame breaker 125/5
MPCT150 C frame breaker 150/5
MPCT250 C frame breaker 250/5
MPCT400 L frame breaker 400/5
MPCT600 M & P frame breakers 600/5
Blank metering platesReference number
3908 Cream 96sq blanking plate
SDBL96 Black/Grey 96mm2
PowerLogic metersReference number
PM700 Multi function PowerMeter
PM700P Multi function PowerMeter with pulse outputs
PM710 Multi function PowerMeter with Modbus RS485 output
PM750 Multi function PowerMeter with Modbus RS485 and pulse outputs
46
> Switch and fusegearTwinbreak & Quadbreak
46
47
Switch and fusegear - Twinbreak
Switch disconnector fuseApplicationHeavy duty fuse products for use in commercial and industrial environments, providing isolation and traditional fuse protection for electrical loads.Featuresn Rated for 240/415V 50/60Hzn Ratings 20A, 32A, 63A, 100A, SP&SwN, TP&Nn Utilisation category AC20A, AC21A, AC22A, AC23B at rated currentn Degree of protection IP41n Handle position provides positive contact indicationn Door handle prevents door being opened when switch is ON or padlockedn Handle padlockable in ON and OFF positionsn Fuse links supplied as standardConstructionn Live terminals fully shroudedn Door interlock has integral defeat mechanism allowing door to be opened without switching OFF. This feature is not operable when the handle is padlockedn Removable gland plates with cable knockoutsn Lift off door provides greater access for installation and cablingn Door opens within the width of the unit allowing units to be mounted adjacentn Neutral has disconnectable link and capacity for 3 outgoing cablesn Keyhole slots in the enclosure base allow easy installationn Earthing kit provided as standardn Easy access to fuse links n Steelwork finished in polyester epoxy powder
SBC106 is supplied complete with 4 x TBCKIT. SBC109 is supplied complete with 6 x TBCKIT.
Technical dataStandard BS EN 60947-3
Rated operational voltage 415V 50/60Hz
Rating 20A 32A 63A 100A
Rated current at 400C, A 20 32 63 100
Rated impulse voltage 6kV 6kV 6kV 6kV
Rated short time withstand Icw, A 416 416 756 1300
Rated short circuit making capacity Icm 1.35kA 1.35kA 1.35kA 3.5kA
Rated short circuit breaking capacity Icn 50kA 50kA 50kA 50kA
Utilisation category at rated current AC-20A/ 21A/ 22A/ 23B
Kilowatt rating 11kW 15kW 30kW 55kW
Cable size, maximum mm2 10mm2 10mm2 25mm2 50mm2
Reference numbersRating Single pole & switched neutral Three pole with neutral link AC21/22/23 Switch Switch Switch Switch disconnector disconnector disconnector disconnector fuse fuse
20A SD202SFK SD202SW SD203SFK SD203SW
32A SD322SFK SD322SW SD323SFK SD323SW
63A SD632SFK SD632SW SD633SFK SD633SW
100A SD1002SFK SD1002SW SD1003SFK SD1003SW
125A – – – SD1253SW
160A – – – SD1603SW
Busbar chambersStep 1Select Twinbreak units required. If a 125 or 160A unit is fitted the rating of the adjacent units cannot exceed 63A.Step 2Select appropriate busbar chamber.
Current rating Number of units Number of unitsAmps 4 6
160 SBC106 SBC109
48
Switch and fusegear - Quadbreak
Fuse switch disconnectorApplicationHeavy duty fuse products for use in commercial and industrial environments, providing isolation and traditional fuse protection for electrical loads.
Featuresn Rated for 240/415V 50/60Hzn Ratings 100A, 160A, 200A, 250A, 315A, 400A, 500A, 630A TP&Nn Utilisation category AC20A, AC21A, AC22A, AC23B at rated current, AC23A for ratings up to 160An Handle position provides positive contact indicationn Door handle prevents door being opened when switch is ON or padlockedn Handle padlockable in ON and OFF positionsn Device may be fed to either top or bottom terminalsn Fuse links or copper links supplied as standard
Constructionn All terminals are fully shroudedn Quick make and break silver plated contactsn Door interlock has defeat mechanism allowing switch to be closed with door openn Removable plain gland plates are fitted at top and bottomn Cabling space may be increased by the addition of the cable boxesn Lift off door provides greater access for installation and cablingn Door opens within the width of the unit allowing units to be mounted adjacentn Neutral is fitted with disconnectable links n Earthing kit provided as standardn Easy access to fuse linksn Removable cross rails allow cables to be laid in easilyn Direct front access to terminals without dismantling the mechanismn Clear shrouds allow easy access for inspection and visual indication of contact position n Steelwork finished in polyester epoxy powder
Reference numbersRating Single pole & switched neutral Three pole with neutral link AC21/22/23 Switch Switch Switch Switch Recommended Spare disconnector disconnector disconnector disconnector cable box links fuse fuse
63A SQB0632K SQB0632L SQB0633K SQB0633L
100A SQB1002K SQB1002L SQB1003K SQB1003L SQBX100
XCL160
160A SQB1602K SQB1602L SQB1603K SQB1603L SQBX160
200A SQB2002K SQB2002L SQB2003K – SQBX250
–
250A SQB2502K SQB2502L SQB2503K SQB2503L XCL250
315A – – SQB3153K – –
400A – – SQB4003K SQB4003L SQBX500 XCL400
500A – – SQB5003K SQB5003L XCL630
630A – – SQB6303K SQB6303L SQBX630
800A – – – SQB8003L XCL800
Castell figure locksQuadbreak can be factory fitted with Castell interlock type FS for locking in off position.To order:1 Specify required unit e.g. SQB2503K2 Add Castle figure lock order suffix EY3 Add Castle key symbol e.g. A
Thus the order reference for a 250A switch disconnector fuse fitted with a Castell lock symbol A is SQB2503KEYA.
49
Switch and fusegear - Quadbreak busbar chambers
Busbar chambersPrimarily designed for Quadbreak switch disconnector (fuse) the Quadbreak busbar chamber can be used for the mounting of any equipment.n Manufactured in accordance with BS EN 60439-1n 200, 400, 630 and 800 rated copper busbarsn Available in 750, 1200 and 1800mm lengthsn Rigid constructionn Copper link kits available for direct connection of Quadbreak switch disconnector (fuse)n Overall height and depth of units remains unchanged for the different current ratings
Height = 450mmDepth = 215mm
* The busbar connection kits allow 2 or more busbar chambers to be electrically and mechanically joined together providing facilities for a greater number of outgoing circuits.** The cable connection kits comprise 4 bolts, nuts and washers to connect a set of cables fitted with crimped lugs to the busbars.
Busbar chamber ratings
Busbar connection kitsEach kit comprises connections for three phases and neutral.
Fuse switch connection kitsEach kit comprises connections for three phases and neutral.
Rating (A) Length 750mm Length 1200mm Length 1800mm
Reference number Reference number Reference number
200 SBC20007TN SBC20012TN SBC20018TN
400 SBC40007TN SBC40012TN SBC40018TN
630 SBC63007TN SBC63012TN SBC63018TN
800 SBC80007TN SBC80012TN SBC80018TN
Busbar interconnections Flexible busbar Cable connections to link busbar interconnections to connect Rating (A) chambers* to link non Square D to busbars** busbar chambers Reference number Reference number Reference number
200 CEC200 – FTC200
400 CEC400 CED400 FTC400
600 CEC630 CED630 FTC600
800 CEC800 CED800 FTC800
Rating (A) Top mounted Bottom mounted
Reference number Reference number
63/160A QBL160TN QBL160TN
200/250A QBL250TN QBL250TN
315/630A QBL630TTN QBL630BTN
800A – QBL800BTN
50
Switch and fusegear - Quadbreak dimensions
Fuse switch disconnector
Busbar chambers
C6
L
J
3333
33
G
25
H
EARTH BOLT
CASTELL
LOCK
END PLATE
EF F
B
60
60
A
CABLE ENTRY
BOX
D
K
Reference Dimensions (mm) Packed number A B C weight (kg)
SBC106 600 350 120 9.6
SBC109 900 350 120 14.25
Current Reference Switch enclosures (mm) Packed Reference Cable entry box (mm)rating number A B C D E F G H weight (kg) number J K L
63A SQB0632K SQB0633K
380 292 200 260 130 81 142 226 14.5 SQBX100 100 292 200 SQB0632L SQB0633L
100A SQB1002K SQB1003K
380 292 200 260 130 81 142 226 15.6 SQBX100 100 292 200 SQB1002L SQB1003L
160A SQB1602K SQB1603K
380 292 200 260 130 81 142 226 15.6 SQBX160 150 292 200 SQB1602L SQB1603L
SQB2003K 200A/ SQB2502K 250A SQB2503K 380 340 200 260 180 81 142 274 19.5 SQBX250 180 340 200 SQB2502L SQB2503L
315A/ SQB3153K400A SQB4003K SQB4003L 455 489 270 335 289 100 212 423 36.2 SQBX500 300 489 270500A SQB5003K SQB5003L
630A SQB6303K 800A SQB6303L 455 489 270 335 289 100 212 423 36.2 SQBX630 400 489 270 SQB8003L
800A unit is provided with cable extension pads which are external to the above dimensions. Cable entry box SQBX630 must be used except where fitted to a Quadbreak busbar chamber.
51
Index
Product Code
Page No.
Product Code
Page No.
Product Code
Page No.
Product Code
Page No.
3908 45
46996 42
400INSKN 38
400kW 38
600INSKN 38
630kW 38
AHEXLI 42
CDXAE34016 30, 33, 36
CDXAE34025 30, 33, 36
CDXAE34032 30, 33, 36
CDXAE34040 30, 33, 36
CDXAE34050 30, 33, 36
CDXAE34063 30, 33, 36
CDXAE34080 30, 33, 36
CDXAE34100 30, 33, 36
CEC200 49
CEC400 49
CEC630 49
CEC800 49
CED400 49
CED630 49
CED800 49
CHAXE34250 32
CHXAE34016 30, 33, 36
CHXAE34025 30, 33, 36
CHXAE34032 30, 33, 36
CHXAE34040 30, 33, 36
CHXAE34050 30, 33, 36
CHXAE34063 30, 33, 36
CHXAE34080 30, 33, 36
CHXAE34100 30, 33, 36
CHXAE34125 30, 33, 36
CHXAE34160 30, 33, 36
CHXAE34200 30, 33, 36
CHXAE34250 29, 30, 33, 36
CNAXE34000S10 29, 32
CNAXE34000S15 29, 32
CNAXE34000S25 29, 32
CNXAE24250E20 30, 33, 36
CNXAE34016 30, 33, 36
CNXAE34025 30, 33, 36
CNXAE34032 30, 33, 36
CNXAE34040 30, 33, 36
CNXAE34050 30, 33, 36
CNXAE34063 30, 33, 36
CNXAE34080 30, 33, 36
CNXAE34100 30, 33, 36
CNXAE34125 30, 33, 36
CNXAE34160 30, 33, 36
CNXAE34160E20 30, 33, 36
CNXAE34200 30, 33, 36
CNXAE34250 29, 33, 36
CPS9 13
DOM03B6 7, 9
DOM06B6 7, 9
DOM06B6R30 7, 9
DOM06C6 7, 9
DOM100R100 6, 9
DOM100R100SP 6, 9
DOM100R30P 6, 9
DOM100SW 6, 9
DOM10B6 7, 9
DOM10B6R30 7, 9
DOM10C6 7, 9
DOM12CU 6, 8
DOM12MCU 6, 8
DOM16B6 7, 9
DOM16B6R30 7, 9
DOM16BKIT 7
DOM16C6 7, 9
DOM16CU 6, 8
DOM16MCU 6, 8
DOM20B6 7, 9
DOM20B6R30 7, 9
DOM20CU 6, 8
DOM2CU 6, 8
DOM2MCU 6, 8
DOM32B6 7, 9
DOM32B6R30 7, 9
DOM40B6 7, 9
DOM40B6R30 7, 9
DOM45B6 7, 9
DOM45B6R30 7, 9
DOM4CU 6, 8
DOM4MCU 6, 8
DOM50B6 7, 9
DOM63R30 6, 9
DOM63R30KIT2 6
DOM63SW 6, 9
DOM6CU 6, 8
DOM6MCU 6, 8
DOM80R30 6, 9
DOM80R30KIT2 6
DOM8CU 6, 8
DOM8MCU 6, 8
DOMEARTHKIT 7
DOMLKIT 7, 13
DOMR4R4CU 6, 8
DOMR4R4MCU 6, 8
DOMR6R6CU 6, 8
DOMR6R6DCU 6, 8
DOMR6R6DMCU 6, 8
DOMR6R6MCU 6, 8
DOMR8R8DCU 6, 8
DOMS2R5R5DCU 6, 8
DOMS2R5R5DMCU 6, 8
DOMS2R7R7DCU 6, 8
EXM522051 31
EXMS1170 34
EXMS1742 34
EXMS20411 31
EXMS53 38
EXMS62 38
EXMS71 38
EXMS80 38
EXMS827 34
EXS151 34
EXS29 38
EXS91 31
FTC200 49
FTC400 49
FTC630 49
FTC800 49
FTS 42
GARAGE63D 6
HNF1BL 34, 38
HNF4BL 34, 38
HNM1BL 31, 43, 40
HNM4BL 31, 43, 40
HPAFK 41
HPALM 34
HPALM 41
HPAXLM 41
KITBOXD 7
KITBOXD80 7
KITBOXDM 7
KITBOXDM1263 7
KITBOXDM1280 7
KQ10C3100 24
KQ10C380 24
KQK33 31, 34, 38, 40
LA11021 43
LA11027 43
LA11037 43
LA11121 43
LA11124 43
LA11127 43
LA11212 43
LA11352 43
LATK3 42
LCA1 42
LV425252 30, 33, 36
LV429242 30, 33, 36
LV429242 42
LV429252 42
LV429253 42
LV429254 42
LV429259 30, 33, 36, 42
LV429386 43
LV429387 43
LV429390 43
LV429406 43
LV429407 43
LV429410 43
LV429450 43
LV429504 42
LV429506 42
LV429515 42
LV429517 42
LV431563 42
MAHEX 42
MCA1 42
ML630 35
MP250121 29
MP25061 29
MP250INS 31
MP250kW 31
MP400121 32
MP40041 32
MP40071 32
MP400INS 34
MP400kW 34
MP630102 35
MP630142 35
MP630182 35
MP63062 35
MPCT125 33, 37, 45
MPCT150 33, 37, 45
MPCT250 33, 37, 45
MPCT400 37
MPCT600 37
MPME2501 30
MPMK104 33, 44
MPMK107 33, 44
MPMK112 33, 44
MPMK206 37, 44
MPMK210 37, 44
MPMK214 37, 44
MPMK218 37, 44
MSIL636 38
NE13150 41
NE1816 41
NE7150 41
NE916 41
NE950 41
PJA36000560 35
PJA36060CU31A 35
PJTK3 42
PM700 33, 37, 45
PM700P 33, 37, 45
PM710 33, 37, 45
PM750 33, 37, 45
QBL160TN 49
QBL160TN 49
QBL250TN 49
QBL250TN 49
QBL630BTN 49
QBL630TTN 49
QBL800BTN 49
QOEPLA 13
QOKS1 31, 34, 40
QOPL 13
RSD4IP54 26
SBC106 47, 50
SBC109 47, 50
SBC20007TN 49
SBC20012TN 49
SBC20018TN 49
SBC40007TN 49
SBC40012TN 49
SBC40018TN 49
SBC63007TN 49
52
Index
SE10C332 24
SE10C340 24
SE10C350 24
SE10C363 24
SE10D106 24
SE10D110 24
SE10D116 24
SE10D120 24
SE10D125 24
SE10D132 24
SE10D140 24
SE10D150 24
SE10D163 24
SE10D206 24
SE10D210 24
SE10D216 24
SE10D220 24
SE10D225 24
SE10D232 24
SE10D240 24
SE10D250 24
SE10D263 24
SE10D306 24
SE10D310 24
SE10D316 24
SE10D320 24
SE10D325 24
SE10D332 24
SE10D340 24
SE10D350 24
SE10D363 24
SE1100L 20
SE1100L 23
SE125A12 19
SE125A16 19
SE125A24 19
SE125A4SL6 19
SE125A4SL8 19
SE125A5SL5 19
SE125A6 19
SE125A6SL6 19
SE125A8 19
SE125L2 20
SE125L4 22
SE125SPP 23
SE125SW2 20
SE125SW3L 22
SE125SW4 22
SE12B250 21
SE12B2D 21
SE12B2D 27
SE12BCD 27
SE160MCCB3L 22
SE160RCD 22
SE160SW3L 22
SE160SW4 22
SE172BES 27
SE17BES 21
SE18B250 21
SE18B2D 21, 27
SE18BCD 27
SE200MCCB3L 22
SE200SW3L 22
SE200SW4 22
SE24B250 21
SE250L4P 22
SE250MCCB3L 22
SE250MET 22
SE250SPP 23
SE250SW3L 22
SE250SW4 22
SE36B250 21
SE36B3D 21, 27
SE36BCD 27
SE48B250 21
SE54B250 21
SE54B4D 21, 27
SE54BCD 27
SE63SLK 21, 23
SE72B250 21
SE72BL 23
SEA12S12 19
SEAE16 20
SEB36S24125 22
SEB36S24250 22
SEB42S18125 22
SEB42S18250 22
SEB48S12125 22
SEB48S12250 22
SEBEK1 23
SEBEK2 23
SEBEK3 23
SEBES 23, 27
SEBFCF 23
SEBNC 23
SEBP25 20
SECE12T 23
SECE24T 23
SECSW100 22
SED100032 20, 26
SED100102 20, 26
SED100304 22, 26
SED100304S 22, 26
SED25032 26
SED25034 26
SED25104 26
SED25302 26
SED25304 26
SED40032 26
SED40034 26
SED40102 26
SED40104 26
SED40302 26
SED40304 26
SED63032 20
SED63032 26
SED63034 26
SED63102 20
SED63102 26
SED63104 26
SED63302 20
SED63302 26
SED63304 26
SED80032 26
SED80034 22
SED80034 26
SEE106B03 25
SEE106C01 25
SEE106C03 25
SEE106C10 25
SEE110B03 25
SEE110C01 25
SEE110C03 25
SEE110C10 25
SEE116B03 25
SEE116C01 25
SEE116C03 25
SEE116C10 25
SEE120B03 25
SEE120C01 25
SEE120C03 25
SEE120C10 25
SEE125B03 25
SEE125C01 25
SEE125C03 25
SEE125C10 25
SEE132B03 25
SEE132C01 25
SEE132C03 25
SEE132C10 25
SEE140B03 25
SEE140C01 25
SEE140C03 25
SEE140C10 25
SEE145B03 25
SEE145C01 25
SEE145C03 25
SEE145C10 25
SEEXGP 23
SEGP 23
SEGPKO 23
SEJK 21, 23
SEK 20, 23
SEK33 23
SEPD 23
SEPL 20, 23
SEPLMCB 20, 23
SEPLRCBO 20, 23
SESDC 20, 23
SESJK 23
SFA1016A,B,C 29, 32, 35
SFA1020A,B,C 29, 32, 35
SFA1032A,B,C 29, 32, 35
SFA1040A,B,C 29, 32, 35
SBC63012TN 49
SBC63018TN 49
SBC80007TN 49
SBC80012TN 49
SBC80018TN 49
SD1002SFK 47, 50
SD1002SW 47, 50
SD1003SFK 47, 50
SD1003SW 47, 50
SD1253SW 47, 50
SD1603SW 47, 50
SD202SFK 47, 50
SD202SW 47, 50
SD203SFK 47, 50
SD203SW 47, 50
SD322SFK 47, 50
SD322SW 47, 50
SD323SFK 47, 50
SD323SW 47, 50
SD632SFK 47, 50
SD632SW 47, 50
SD633SFK 47, 50
SD633SW 47, 50
SDBL96 45
SE100MCCB3L 22
SE10B103 24
SE10B106 24
SE10B110 24
SE10B116 24
SE10B120 24
SE10B125 24
SE10B132 24
SE10B140 24
SE10B150 24
SE10B163 24
SE10C106 24
SE10C110 24
SE10C116 24
SE10C120 24
SE10C125 24
SE10C132 24
SE10C140 24
SE10C150 24
SE10C163 24
SE10C206 24
SE10C210 24
SE10C216 24
SE10C220 24
SE10C225 24
SE10C232 24
SE10C240 24
SE10C250 24
SE10C263 24
SE10C306 24
SE10C310 24
SE10C316 24
SE10C320 24
SE10C325 24
Product Code
Page No.
Product Code
Page No.
Product Code
Page No.
Product Code
Page No.
53
Index
SFA1050A,B,C 29, 32, 35
SFA1063A,B,C 29, 32, 35
SFA1080A,B,C 29, 32, 35
SFA1100A,B,C 29, 32, 35
SFA2016AB,BC,AC 29, 32, 35
SFA2020AB,BC,AC 29, 32, 35
SFA2032AB,BC,AC 29, 32, 35
SFA2040AB,BC,AC 29, 32, 35
SFA2050AB,BC,AC 29, 32, 35
SFA2063AB,BC,AC 29, 32, 35
SFA2080AB,BC,AC 29, 32, 35
SFA2100AB,BC,AC 29, 32, 35
SHOWER6340D 6
SHOWER6345D 6
SL100 43
SL225 29, 32, 43
SL400 43
SL800 43
SLA3000M 32, 35
SLA3250 35
SLA3400 32, 35
SQB0632K 48, 50
SQB0632L 48, 50
SQB0633K 48, 50
SQB0633L 48, 50
SQB1002K 48, 50
SQB1002L 48, 50
SQB1003K 48, 50
SQB1003L 48, 50
SQB1602K 48, 50
SQB1602L 48, 50
SQB1603K 48, 50
SQB1603L 48, 50
SQB2002K 48, 50
SQB2002L 48, 50
SQB2003K 48, 50
SQB2502K 48, 50
SQB2502L 48, 50
SQB2503K 48, 50
SQB2503L 48, 50
SQB3153K 48, 50
SQB4003K 48, 50
SQB4003L 48, 50
SQB5003K 48, 50
SQB5003L 48, 50
SQB6303K 48, 50
SQB6303L 48, 50
SQB8003L 48, 50
SQBX100 48, 50
SQBX250 48, 50
SQBX500 48, 50
SQBX630 48, 50
SQO103EB6 13, 17
SQO103EC6 13, 17
SQO106EB6 13, 17
SQO106EC6 13, 17
SQO1100L 12, 17
SQO1100M 12, 17
SQO110EB6 13, 17
SQO110EC6 13, 17
SQO116EB6 13, 17
SQO116EC6 13, 17
SQO12 12, 14
SQO120EB6 13, 17
SQO120EC6 13, 17
SQO125EB6 13, 17
SQO125EC6 13, 17
SQO132EB6 13, 17
SQO132EC6 13, 17
SQO140EB6 13, 17
SQO140EC6 13, 17
SQO150EB6 13, 17
SQO150EC6 13, 17
SQO16 12, 14
SQO163EB6 13, 17
SQO163EC6 13, 17
SQO2 12, 14
SQO204 12, 16
SQO23 12, 14
SQO303 12, 16
SQO4 12, 14
SQO402 12, 16
SQO406 12, 16
SQO505 12, 16
SQO6 12, 14
SQO604 12, 16
SQO703 12, 16
SQO707 12, 16
SQO8 12, 14
SQODNBP 13, 20, 23
SQODS2R5R5 12, 15
SQOE063030 12, 17, 20
SQOE063100 12, 17, 20
SQOE100030 12, 17, 20
SQOE100100 12, 17, 20
SQOE100100S 12, 17, 20
SQOE100300 12, 17, 20
SQOM12 12, 14
SQOM16 12, 14
SQOM2 12, 14
SQOM24 12, 14
SQOM4 12, 14
SQOM505 12, 15
SQOM6 12, 14
SQOM604 12, 16
SQOM60501 12, 16
SQOM70401 12, 16
SQOM707 12, 16
SQOM8 12, 14
SQOMDS2R5R5 12, 15
SQOMS2R5R5 12, 15
SQOMS4R6 12, 15
SQOMS5R5 12, 15
SQOMS6R4 12, 15
SQOMS7R7 12, 15
SQOMSR6R6 12, 15
Product Code
Page No.
Product Code
Page No.
Product Code
Page No.
Product Code
Page No.
SQOR106B03 13, 17
SQOR110B03 13, 17
SQOR116B03 13, 17
SQOR120B03 13, 17
SQOR132B03 13, 17
SQOR145B03 13, 17
SQOS2R4 12, 15
SQOS2R5R5 12, 15
SQOS3R3 12, 15
SQOS4R2 12, 15
SQOS4R6 12, 15
SQOS5R5 12, 15
SQOS6R4 12, 15
SQOS7R3 12, 15
SQOS7R7 12, 15
SQOSR6R6 12, 15
TKA12 32, 34
TKA4 32, 34
TKA7 32, 34
W29370 23, 31, 41
WALLET 23
XCL250 48
XCL400 48, 50
XCL630 48
XCL800 48
54
Notes
55
Notes
UK contact details -
0870 608 8 608Fax 0870 608 8 606
Ireland contact details -
01 601 2200Fax 01 601 2201
As a global specialist in energy management with operations in more than 100 countries, Schneider Electric offers integrated solutions across multiple market segments, including leadership positions in Utilities & Infrastructures, Industries & Machine Manufacturers, Non-residential Buildings, Data Centres & Networks and in Residential .
Focused on making energy safe, reliable, efficient, productive and green, the Group’s 130,000 plus employees achieved sales of 22.4 billion euros in 2011, through an active commitment to help individuals and organisations make the most of their energy.
We are changing our brand names and becoming one Schneider Electric. You’ll get the same great quality products, but from one name you can remember and trust. This provides you and your customers with the reassurance associated with Schneider Electric.
Some of our market leading brands have already become Schneider Electric including Merlin Gerin, Telemecanique, Square D, GET, Mita, Sarel, Himel, Thorsman, Tower and TAC.
Working as one Schneider Electric makes it clearer that our ranges are highly compatible for integrated solutions.
Schneider Electric Ltd
Schneider Electric Limited is a company registered in England and Wales.Registered number: 1407228. Registered office: Stafford Park 5, Telford, Shropshire TF3 3BL.
© 2012 Schneider Electric. All Rights Reserved. Schneider Electric, Active Energy Management, Compact, EcoStruxure, ION Enterprise, iRIO, Make the most of your energy, Masterpact, Micrologic, Power Plant To Plug, Modbus, and PowerLogic are owned by Schneider Electric Industries SAS, or its affiliated companies in the United States and other countries.