Ready to install Distribution and protection products

Upload: others

Post on 16-Mar-2021

5 views

Category:

Documents


0 download

TRANSCRIPT

Page 1: Ready to install€¦ · 8 Domae consumer units - dimensions & technical data Insulated units Reference number No. of ways Height (mm) Width (mm) Depth (mm) DOM2CU 2 240 189 127 DOM4CU

Ready to installDistribution and protection products

Page 2: Ready to install€¦ · 8 Domae consumer units - dimensions & technical data Insulated units Reference number No. of ways Height (mm) Width (mm) Depth (mm) DOM2CU 2 240 189 127 DOM4CU

2

Page 3: Ready to install€¦ · 8 Domae consumer units - dimensions & technical data Insulated units Reference number No. of ways Height (mm) Width (mm) Depth (mm) DOM2CU 2 240 189 127 DOM4CU

3

ContentsDomae consumer units . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 4Features and benefits . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 5Quick selector - reference numbers and descriptions . . . . . . . . . . . . . . . . . . . . . . . . . 6Consumer unit - dimensions and technical data . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 8Devices - technical data . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 9

Qwikline ll consumer units . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 10Features and benefits . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 11Quick selector - reference numbers and descriptions . . . . . . . . . . . . . . . . . . . . . . . . 12Standard consumer units - technical data . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 14Split load consumer units - technical data . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 15Dual/multi tariff consumer units - technical data . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 16Devices - technical data . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 17

LoadCentre KQ distribution boards . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 18Single phase A type distribution boards - 125A . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 19Three phase B type distribution boards - 250A . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 21Three phase B type distribution boards - metered . . . . . . . . . . . . . . . . . . . . . . . . . . . 22iKQ miniature circuit breakers (MCB’s) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 24Residual current circuit breakers (RCBO’s) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 25Residual current circuit breakers (RCCB’s) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 26Extension enclosures . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 27

Panelboards . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 28I-Line MCCB panelboards Size 1 250A . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 29I-Line MCCB panelboards Size 1 400A . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 32I-Line MCCB panelboards Size 2 630A . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 35Panelboard accessories . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 40MCCB accessories . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 42Metering facilities . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 44

Switch and fusegear . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 46Twinbreak . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 47Quadbreak . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 48Quadbreak busbar chambers . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 49Quadbreak dimensions . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 50

Index . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 51

Page 4: Ready to install€¦ · 8 Domae consumer units - dimensions & technical data Insulated units Reference number No. of ways Height (mm) Width (mm) Depth (mm) DOM2CU 2 240 189 127 DOM4CU

4

Domae consumer unitsThe Domae range of consumer units offers the ultimate in terms of onsite flexibility at a very affordable price .

There are no bespoke split load consumer units, however any

Domae enclosure can be taken and used with a single incomer or

converted to a split load board with the minimum of effort.

A wide range of RCD protected and unprotected ways is possible and a standard board can be converted to a split load type at any time in the future. In terms of safety Domae offers a wide range of protective devices and installer safety is maximised via a busbar shield which, once fitted, can only be removed with the use of a tool.

Domae is now available with insulated or metal enclosures.

Page 5: Ready to install€¦ · 8 Domae consumer units - dimensions & technical data Insulated units Reference number No. of ways Height (mm) Width (mm) Depth (mm) DOM2CU 2 240 189 127 DOM4CU

5

Domae consumer unitsFeatures and benefits

Highly flexible Domae consumer units can be used with a single main incomer or used as a split load board

Configurable on site Choose the split of protected or unprotected RCD ways. Standard single incomer boards can be converted to split load at a later date

Ideal for rewire applications Right hand incomer for easier installation where existing incoming cables fall on the right

Controls flexibility Control devices can be easily installed within the same enclosure

Additional installer safety The busbar shield is firmly held in place when fitted and requires a tool to remove

Value for money Backed by the Schneider Electric brand you can be assured that Domae is a cost effective and quality solution

Page 6: Ready to install€¦ · 8 Domae consumer units - dimensions & technical data Insulated units Reference number No. of ways Height (mm) Width (mm) Depth (mm) DOM2CU 2 240 189 127 DOM4CU

6

Domae - quick selector

Select consumer unitInsulated units

Reference number No. of ways Reference number No. of waysDOM2CU 2 DOM2MCU 2

DOM4CU 4 DOM4MCU 4

DOM6CU 6 DOM6MCU 6

DOM8CU 8 DOM8MCU 8

DOM12CU 12 DOM12MCU 12

DOM16CU 16 DOM16MCU 16

DOM20CU 20

Select incoming deviceMain incoming devices

Reference number Description Current rating

DOM63SW Switch 63A

DOM100SW Switch 100A

DOM63R30 RCCB 63A 30mA

DOM80R30 RCCB 80A 30mA

DOM100R100 RCCB 100A 100mA

DOM100R100SP RCCB (TD) 100A 100mA

DOM100R30P RCCB 100A 30mA

For split load applications select a split load kitSplit load kits [includes cables and RCCB (RCD)]

Reference number Description Current rating

DOM63R30KIT2 RCCB and cables 63A 30mA

DOM80R30KIT2 RCCB and cables 80A 30mA

Select consumer unit packagePre-assembled ready to install consumer unit packages

Reference number Description Typical application

SHOWER6340D 2 way enclosure + 63A 30mA RCCB and 40A MCB Electric shower supply

SHOWER6345D 2 way enclosure + 63A 30mA RCCB and 45A MCB Electric shower supply

GARAGE63D 2 way IP55 enclosure + 63A RCD, 6A and 16A MCB Electricity supply to a garage

Select consumer units with switch/RCD’s fittedSplit load kits [includes cables and RCCB (RCD)]

Reference numberInsulated Units

Reference numberMetal units

Total no. ways

DescriptionSwitch only ways

RCD1 protected ways

RCD2 protected ways

DOMR4R4CU DOMR4R4MCU 8 4 + 4 way configurable Domae CU 100A Sw and 2 63A RCDs

4 4

DOMR6R6CU DOMR6R6MCU 12 6 + 6 way configurable Domae CU 100A Sw and 2 63A RCDs

6 6

DOMR6R6DCU DOMR6R6DMCU 12 6 + 6 way configurable Domae CU 100A Sw and 2 80A RCDs

6 6

DOMR8R8DCU 16 8 + 8 way configurable Domae CU 100A Sw and 2 80A RCDs

8 8

DOMS2R5R5DCU DOMS2R5R5DMCU 12 2 + 5 + 5 way Domae CU 100A Sw and 2 80A RCDs

2 5 5

DOMS2R7R7DCU 16 2 + 7 + 7 way Domae CU 100A Sw and 2 80A RCDs

2 7 7

Metal units

Page 7: Ready to install€¦ · 8 Domae consumer units - dimensions & technical data Insulated units Reference number No. of ways Height (mm) Width (mm) Depth (mm) DOM2CU 2 240 189 127 DOM4CU

7

Domae - ready to install consumer unit packagesDomae ready to install consumer unit packages are supplied complete with enclosure, incoming and outgoing devices and all internal connections required. Order 1 part number then simply fix, connect, test and energise.

Select outgoing devices or accessoriesSP 6kA MCBs (B curve)

Reference number Description Current rating

DOM03B6 MCB (B curve) 3A

DOM06B6 MCB (B curve) 6A

DOM10B6 MCB (B curve) 10A

DOM16B6 MCB (B curve) 16A

DOM20B6 MCB (B curve) 20A

DOM32B6 MCB (B curve) 32A

DOM40B6 MCB (B curve) 40A

DOM45B6 MCB (B curve) 45A

DOM50B6 MCB (B curve) 50A

SP 6kA MCBs (C curve)

Reference number Description Current rating

DOM06C6 MCB (C curve) 6A

DOM10C6 MCB (C curve) 10A

DOM16C6 MCB (C curve) 16A

Accessories

Reference number Description

DOMLKIT Door lock kit (for metal enclosure only)

DOMEARTHKIT Additional earth terminals for clean earth or high integrity earthing

DOM16BKIT Replacement/spare main busbar

SQODNBP Blanking plate

SP 6kA 1 module RCBO (B curve)

Reference number Description Current rating

DOM06B6R30 RCBO 30mA 1 Module 1P&N 6A

DOM10B6R30 RCBO 30mA 1 Module 1P&N 10A

DOM16B6R30 RCBO 30mA 1 Module 1P&N 16A

DOM20B6R30 RCBO 30mA 1 Module 1P&N 20A

DOM32B6R30 RCBO 30mA 1 Module 1P&N 32A

DOM40B6R30 RCBO 30mA 1 Module 1P&N 40A

DOM45B6R30 RCBO 30mA 1 Module 1P&N 45A

Insulated kitboxPre-assembled ready to install consumer unit packages

Reference number Description Typical application

KITBOXD 12 way enclosure, switch, 63A 30mA RCCB kit, 3 x 6A MCB’s, 2 x 16A MCB’s, 4 x 32A MCB’s, 1 x 40A MCB

General residential rebuild or rewire

KITBOXD80 12 way enclosure, switch, 80A 30mA RCCB kit, 3 x 6A MCB’s, 2 x 16A MCB’s, 4 x 32A MCB’s, 1 x 40A MCB

General residential rebuild or rewire

Metal kitboxPre-assembled ready to install consumer unit packages

Reference number Description Typical application

KITBOXDM 12 way enclosure, switch, 63A 30mA RCCB kit, 3 x 6A MCB’s, 2 x 16A MCB’s

General residential rebuild or rewire

KITBOXDM1263 12 way enclosure, switch, 63A 30mA RCCB kit, 2 x 6A MCB’s, 2 x 16A MCB’s, 3 x 32A MCB’s, 1 x 40A MCB

General residential rebuild or rewire

KITBOXDM1280 12 way enclosure, switch, 80A 30mA RCCB kit, 3 x 6A MCB’s, 2 x 16A MCB’s, 3 x 32A MCB’s, 1 x 40A MCB

General residential rebuild or rewire

Page 8: Ready to install€¦ · 8 Domae consumer units - dimensions & technical data Insulated units Reference number No. of ways Height (mm) Width (mm) Depth (mm) DOM2CU 2 240 189 127 DOM4CU

8

Domae consumer units - dimensions & technical data

Insulated unitsReference number No. of ways Height (mm) Width (mm) Depth (mm)

DOM2CU 2 240 189 127

DOM4CU 4 240 224 127

DOM6CU 6 240 260 127

DOM8CU 8 240 296 127

DOM12CU 12 240 368 127

DOM16CU 16 240 440 127

DOM20CU 20 240 510 127

DOMR4R4CU 8 240 368 127

DOMR6R6CU 12 240 440 127

DOMR6R6DCU 12 240 440 127

DOMS2R5R5DCU 12 240 440 127

DOMR8R8DCU 16 240 510 127

DOMS2R7R7DCU 16 240 510 127

Metal unitsReference number No. of ways Height (mm) Width (mm) Depth (mm)

DOM2MCU 2 247 186 111

DOM4MCU 4 247 222 111

DOM6MCU 6 247 258 111

DOM8MCU 8 247 294 111

DOM12MCU 12 247 366 111

DOM16MCU 16 247 438 111

DOMR4R4MCU 8 247 366 111

DOMR6R6MCU 12 247 438 111

DOMR6R6DMCU 12 247 438 111

DOMS2R5R5DMCU 12 247 438 111

Technical dataMax. busbar current (A) 100A

Max. operating voltage 230/240V @ 50Hz

Max. cable capacity 25 mm2 (earth and neutral bars)

Certification BS EN 61439-3

Note: Incoming and outgoing devices must be selected separately from the devices section - only applies to DOM**CU and DOM**MCU

Incoming devices available• Switch disconnector 63A & 100A• RCCB’s 63A/30mA 80A/30mA

Max. busbar splits - for split load8 way 2+4 to 4+212 way 4+6 to 6+416 way 6+8 to 8+6

Fully configurable shrouded busbars

Lockable cover option on metal units

Page 9: Ready to install€¦ · 8 Domae consumer units - dimensions & technical data Insulated units Reference number No. of ways Height (mm) Width (mm) Depth (mm) DOM2CU 2 240 189 127 DOM4CU

9

Domae - device & technical data

Incoming devices - selection and technical data

Referencenumber Description No.

polesCurrentrating

Operatingvoltage (V)

Max. cableCap. mm2

Standardsapproval

Recommended tightening torque

DOM63SW Switch 2 63A 230/240 35 BS EN 60947-3 3.5 N.m.

DOM100SW Switch 2 100A 230/240 50 BS EN 60947-3 3.5 N.m.

DOM63R30 RCCB 2 63A 30mA 230/240 35 BS EN 61008 3.5 N.m.

DOM80R30 RCCB 2 80A 30mA 230/240 50 BS EN 61008 3.5 N.m.

DOM100R100 RCCB 2 100A 100mA 230/240 50 BS EN 61008 3.5 N.m.

DOM100R100SP RCCB (TD) 2 100A 100mA 230/240 50 BS EN 61008 3.5 N.m.

DOM100R30P RCCB 2 100A 30mA 230/240 50 BS EN 61008 3.5 N.m.

Outgoing 6kA MCBs and RCBOs

Referencenumber Description No.

polesCurrentrating

Operatingvoltage (V)

Max. cableCap. mm2

Standardsapproval

Recommended tightening torque

Single pole circuit breaker (B curve)

DOM03B6 MCB 1 3A 230/240 25 BS EN 60898 2 N.m.

DOM06B6 MCB 1 6A 230/240 25 BS EN 60898 2 N.m.

DOM10B6 MCB 1 10A 230/240 25 BS EN 60898 2 N.m.

DOM16B6 MCB 1 16A 230/240 25 BS EN 60898 2 N.m.

DOM20B6 MCB 1 20A 230/240 25 BS EN 60898 2 N.m.

DOM32B6 MCB 1 32A 230/240 35 BS EN 60898 3.5 N.m.

DOM40B6 MCB 1 40A 230/240 35 BS EN 60898 3.5 N.m.

DOM45B6 MCB 1 45A 230/240 35 BS EN 60898 3.5 N.m.

DOM50B6 MCB 1 50A 230/240 35 BS EN 60898 3.5 N.m.

Single pole circuit breaker (C curve)

DOM06C6 MCB 1 6A 230/240 25 BS EN 60898 2 N.m.

DOM10C6 MCB 1 10A 230/240 25 BS EN 60898 2 N.m.

DOM16C6 MCB 1 16A 230/240 25 BS EN 60898 2 N.m.

Single pole circuit breaker (B curve)

DOM06B6R30 1 Module RCBO 1 6A 230/240 25 BS EN 61009 2 N.m.

DOM10B6R30 1 Module RCBO 1 10A 230/240 25 BS EN 61009 2 N.m.

DOM16B6R30 1 Module RCBO 1 16A 230/240 25 BS EN 61009 2 N.m.

DOM20B6R30 1 Module RCBO 1 20A 230/240 25 BS EN 61009 2 N.m.

DOM32B6R30 1 Module RCBO 1 32A 230/240 25 BS EN 61009 2 N.m.

DOM40B6R30 1 Module RCBO 1 40A 230/240 25 BS EN 61009 2 N.m.

DOM45B6R30 1 Module RCBO 1 45A 230/240 25 BS EN 61009 2 N.m.

Page 10: Ready to install€¦ · 8 Domae consumer units - dimensions & technical data Insulated units Reference number No. of ways Height (mm) Width (mm) Depth (mm) DOM2CU 2 240 189 127 DOM4CU

Qwikline II consumer unitsThe Qwikline II range of consumer units provides arguably the highest levels of residential circuit protection safety .A wide range of switch disconnectors, RCDs and MCBs is also complimented by a single pole RCBO offer for maximum continuity of supply in the event of fault.

What really sets Qwikline II apart, is the plug-on breaker concept and fully encapsulated busbars. All outgoing devices can be connected in seconds and with no incoming terminal to tighten, the correct mechanical connection force is guaranteed every time. For unused ways, Qwikline II’s unique fully encapsulated busbar system means that the highest levels of installer and end user protection are always guaranteed.

Even with the front cover of the enclosure removed, the main busbar is protected to IP2X, meaning it remains finger safe but allows access with test probes by the installer.

For energy management and safety Qwikline II can also accept a wide range of control devices.

10

Page 11: Ready to install€¦ · 8 Domae consumer units - dimensions & technical data Insulated units Reference number No. of ways Height (mm) Width (mm) Depth (mm) DOM2CU 2 240 189 127 DOM4CU

Qwikline ll consumer unitFeatures and benefits

Tested in accordance with BS EN 61439-3 and CM16 tested

Unrestricted cable entry can be made from any side

Totally encapsulated busbar system. Provides complete finger safety to IP2XB, bringing new levels of safety to consumer unit design

Incoming devices can be ordered separately giving over 1000 combinations from just 46 references

Single pole RCBO. Tested to BS EN 61009

Unique MCB/RCBO fixing system. Retains plug-on philosophy for speed of installation and guaranteed connections. Provides the additional benefit of a rear clip which increases device security once plugged on

Control devices may be installed on any outgoing way. No extra mounting accessories required

Lockable cover option now available on metal units

11

Page 12: Ready to install€¦ · 8 Domae consumer units - dimensions & technical data Insulated units Reference number No. of ways Height (mm) Width (mm) Depth (mm) DOM2CU 2 240 189 127 DOM4CU

12

Qwikline ll - quick selector

Select consumer unit: insulated unitsStandard

Referencenumber

No. ofways

Referencenumber Cir A RCD ways

Referencenumber Cir A Cir B

SQO2 2 SQOS2R4 2 4 SQO204 2 4

SQO4 4 SQOS3R3 3 3 SQO303 3 3

SQO6 6 SQOS4R2 4 2 SQO402 4 2

SQO8 8 SQOS4R6 4 6 SQO406 4 6

SQO12 12 SQOS5R5 5 5 SQO505 5 5

SQO16 16 SQOS6R4 6 4 SQO604 6 4

SQO23 24 SQOS7R3 7 3 SQO703 7 3

SQOS7R7 7 7 SQO707 7 7

Select consumer unit: metal unitsStandard

Referencenumber

No. ofways

Referencenumber Cir A RCD

ways

Referencenumber Cir A Cir B

Referencenumber Cir A Cir B Cir C

SQOM2 2 SQOMS4R6 4 6 – – – SQOM60501 6 5 1

SQOM4 4 SQOMS5R5 5 5 SQOM505 5 5 SQOM70401 7 4 1

SQOM6 6 SQOMS6R4 6 4 SQOM604 6 4

SQOM8 8 SQOMS7R7 7 7 SQOM707 7 7

SQOM12 12

SQOM16 16

SQOM 24 24

Split load

Split load

Dual incomer

Dual incomer Multi tariff

No. of ways

No. of ways

No. of ways

No. of ways No. of ways

Mutliple split busbars - supplied with switch disconnectors and RCDs

Mutliple split busbars - supplied with switch disconnectors and RCDs

Reference number Total ways Switch ways RCD 1 ways RCD 2 ways

SQOSR6R6 12 – 6 (63A) 6 (63A)

SQODS2R5R5 12 2 5 (100A) 5 (100A)SQOS2R5R5 12 2 5 (63A) 5 (63A)

Reference number Total ways Switch ways RCD 1 ways RCD 2 ways

SQOMSR6R6 12 – 6 (63A) 6 (63A)

SQOMDS2R5R5 12 2 5 (100A) 5 (100A)SQOMS2R5R5 12 2 5 (63A) 5 (63A)

Note: Flush mounted standard metal consumer units are available by adding an ‘F’ suffix to the above part numbers. e.g. SQOM2F = 2 way flush mounted unit.For flush mounting of split load, dual incomer and multi tariff boards use SQOFC12 for 10 module boards and SQOFC16 for 14 module boards.

Note: All Qwikline II consumer units are supplied without incoming devices. Any incoming device may be installed at the incoming point, or busbar split in any Qwikline II consumer unit.

Requirements Standard units – 1 incoming device required.Split load units – 1 main incoming device and 1 busbar split device required.

Dual incomer units – 2 incoming devices required.Multi tariff units – 3 incoming devices required.

Select incoming devicesReference number Description No. of poles Current rating

SQO1100M 2 pole switch disconnector 2 100A

SQO1100L 2 pole terminal block 2 100A

SQOE100030 RCCB 2 100A, 30mA

SQOE100100 RCCB 2 100A, 100mA

SQOE100300 RCCB 2 100A, 300mA

SQOE100100S RCCB 2 100A, 100mA TD

SQOE063030 RCCB 2 63A, 30mA

SQOE063100 RCCB 2 63A, 100mA

Page 13: Ready to install€¦ · 8 Domae consumer units - dimensions & technical data Insulated units Reference number No. of ways Height (mm) Width (mm) Depth (mm) DOM2CU 2 240 189 127 DOM4CU

13

Note: All control devices are suitable for mounting in any Qwikline II consumer unit.

Qwikline ll - quick selector

Select outgoing devicesSP 6kA MCBs (B curve)

Reference number Description Current rating

SQO103EB6 MCB (B Curve) 3A

SQO106EB6 MCB (B Curve) 6ASQO110EB6 MCB (B Curve) 10ASQO116EB6 MCB (B Curve) 16ASQO120EB6 MCB (B Curve) 20ASQO125EB6 MCB (B Curve) 25ASQO132EB6 MCB (B Curve) 32ASQO140EB6 MCB (B Curve) 40ASQO150EB6 MCB (B Curve) 50ASQO163EB6 MCB (B Curve) 63A

Select control devices and accessoriesReference number Device Ways occupied

15959 2P 25A contactor 1

15962 4P 25A contactor 215966 2P 40A contactor 215967 3P 40A contactor 315968 4P 40A contactor 315972 3P 63A contactor 315510 1P Impulse relay (16A) 115520 2P Impulse relay (16A) 115535 Changeover relay (10A) 115321 Bell (8-12V) 115214 Transformer 240-8V (4VA) 215323 Buzzer (8-12V) 1CCT15368 Light sensitive switch 3.515336 Single pole time switch 24hr 1CCT15720 Single channel electrical time switch 7 day 2.5CCT15722 Dual channel electrical time switch 7 day 2.515363 1P Delay off timer 1

SP 6kA MCBs (C curve)

Reference number Description Current rating

SQO103EC6 MCB (C Curve) 3A

SQO106EC6 MCB (C Curve) 6ASQO110EC6 MCB (C Curve) 10ASQO116EC6 MCB (C Curve) 16ASQO120EC6 MCB (C Curve) 20ASQO125EC6 MCB (C Curve) 25ASQO132EC6 MCB (C Curve) 32ASQO140EC6 MCB (C Curve) 40ASQO150EC6 MCB (C Curve) 50ASQO163EC6 MCB (C Curve) 63A

SP 6kA 1 Module RCBO (B curve)

Reference number Description Current rating

SQOR106B03 RCBO (30mA) 1 Module 1P&N 6A, 30mASQOR110B03 RCBO (30mA) 1 Module 1P&N 10A, 30mASQOR116B03 RCBO (30mA) 1 Module 1P&N 16A, 30mASQOR120B03 RCBO (30mA) 1 Module 1P&N 20A, 30mASQOR132B03 RCBO (30mA) 1 Module 1P&N 32A, 30mASQOR145B03 RCBO (30mA) 1 Module 1P&N 45A, 30mA

Accessories

SQODNBP DIN blanking plates 5CPS9 Half mod spacer 0.5QOEPLA Padlock device (suitable for use with all Qwikline II devices) –QOPL Padlock –DOMLKIT Door lock kit (metal units only) –

Page 14: Ready to install€¦ · 8 Domae consumer units - dimensions & technical data Insulated units Reference number No. of ways Height (mm) Width (mm) Depth (mm) DOM2CU 2 240 189 127 DOM4CU

14

Qwikline ll - standard consumer unit technical data

Insulated unitsReference number No. of ways Height (mm) Width (mm) Depth (mm)

SQO2 2 240 189 127

SQO4 4 240 224 127

SQO6 6 240 260 127

SQO8 8 240 296 127

SQO12 12 240 368 127

SQO16 16 240 440 127

SQO23 24 480 368 127

SQOSR6R6 12 240 440 127

SQOS2R5R5 12 240 440 127

SQODS2R5R5 12 240 440 127

Metal unitsReference number No. of ways Height (mm) Width (mm) Depth (mm)

SQOM2 2 247 186 111

SQOM4 4 247 222 111

SQOM6 6 247 258 111

SQOM8 8 247 294 111

SQOM12 12 247 366 111

SQOM16 16 247 438 111

SQOM24 24 247 366 111

SQOMSR6R6 12 247 438 111

SQOMDS2R5R5 12 247 438 111

SQOMS2R5R5 12 247 438 111

Note: Incoming and outgoing devices must be selected separately from the Qwikline ll devices section. The following ref’s are supplied with switch disconnector and RCDs fitted:- SQOSR6R6, SQOS2R5R5, SQODS2R5R5, SQOMSR6R6, SQOMSR5R5, SQOMDSR5R5

Incoming devices available• Switch disconnector – 100A• Terminal block – 100A• RCCB’s – 63A/30mA, 63A/100mA, 100A/30mA, 100A/100mA, 100A/300mA, 100A/100mA TD

Technical dataMetal Insulated

Max. busbar current rating (A) 100 100

Max. operating voltage (V) 240 240

Operating frequency (Hz) 50 50

Max. incoming cable capacity mm2 (phase and neutral) 50 50

Max. outgoing cable capacity mm2 25 25

Certification BS EN 61439-3 BS EN 61439-3

IP rating BS EN 60529 (internal) 2XB 2XB

IncomingSwitch disconnector – 100ATerminal block – 100ARCCB’s – 63 or 100A/30mA, 100 or 300mA

OutgoingMCB’s – B or C curve, 3 - 50A, 6kARCBO’s – B curve 6 - 45A, 6kA

Page 15: Ready to install€¦ · 8 Domae consumer units - dimensions & technical data Insulated units Reference number No. of ways Height (mm) Width (mm) Depth (mm) DOM2CU 2 240 189 127 DOM4CU

15

Qwikline ll - split load consumer unit technical data

Insulated units

Reference numberCir A RCD ways Height Width Depth

SQOS2R4 2 4 240 296 127

SQOS3R3 3 3 240 296 127

SQOS4R2 4 2 240 296 127

SQOS4R6 4 6 240 368 127

SQOS5R5 5 5 240 368 127

SQOS6R4 6 4 240 368 127

SQOS7R3 7 3 240 368 127

SQOS7R7 7 7 240 440 127

Metal units

Reference numberCir A RCD ways Height Width Depth

SQOMS4R6 4 6 247 366 111

SQOMS5R5 5 5 247 366 111

SQOMS6R4 6 4 247 366 111

SQOMS7R7 7 7 247 438 111

Note: Split load units are supplied without incoming devices. These should be selected separately from the Qwikline ll devices section. e.g. SQOS2R4 + SQO1100M + SQOE063030 = 2+4 Split load insulated consumer unit supplied with site installable switch disconnector and 63A 30mA RCCB.

Any RCCB may be selected as the main incomer or split portion device.

Technical dataMetal Insulated

Max. busbar current rating (A) 100 100

Max. operating voltage (V) 240 240

Operating frequency (Hz) 50 50

Max. incoming cable capacity mm2 (phase and neutral) 50 50

Max. outgoing cable capacity mm2 25 25

Certification BS EN 61439-3 BS EN 61439-3

IP rating BS EN 60529 (internal) 2XB 2XB

IncomingSwitch disconnector – 100ATerminal block – 100ARCCB’s – 63 or 100A/30mA, 100 or 300mA

Control devicesMay be installed at any outgoing point on the RCD protected or unprotected side

OutgoingMCB’s – B or C curve, 3 - 50ARCBO’s – B curve 45A, 6kA

Dimensions (mm)

Dimensions (mm)

No. of ways

No. of ways

SplitRCCB – 63 or 100A/30mA,100 or 300mA

Page 16: Ready to install€¦ · 8 Domae consumer units - dimensions & technical data Insulated units Reference number No. of ways Height (mm) Width (mm) Depth (mm) DOM2CU 2 240 189 127 DOM4CU

16

Qwikline ll - dual incomer and multi tariff technical data

Insulated units

Reference numberCir A Cir B Height Width Depth

Dual incomerSQO204 2 4 240 296 127

SQO303 3 3 240 296 127

SQO402 4 2 240 296 127

SQO406 4 6 240 368 127

SQO505 5 5 240 368 127

SQO604 6 4 240 368 127

SQO703 7 3 240 368 127

SQO707 7 7 240 440 127

Metal units

Reference numberCir A Cir B Cir C Height Width Depth

Dual incomerSQOM406 4 6 – 247 378 111

SQOM505 5 5 – 247 378 111

SQOM604 6 4 – 247 378 111

SQOM707 7 7 – 247 450 111

Multi tariffSQOM60501 6 5 1 247 450 111

SQOM70401 7 4 1 247 450 111

Note: Incoming and outgoing devices must be selected separately from the Qwikline ll devices section. One incoming device is required per circuit.

Dimensions (mm)

Dimensions (mm)

No. of ways

No. of ways

IncomingSwitch disconnector – 100ATerminal block – 100ARCCB’s – 63 or 100A/30mA, 100 or 300mA

Control DevicesMay be installed at any outgoing position

OutgoingMCB’s – B or C curve, 3 - 50A, 6kARCBO’s – B curve 6 - 45A, 6kA

Technical dataMetal Insulated

Max. busbar current rating (A) 100 100

Max. operating voltage (V) 240 240

Operating frequency (Hz) 50 50

Max. incoming cable capacity mm2 (phase and neutral) 50 50

Max. outgoing cable capacity mm2 25 25

Certification BS EN 61439-3 BS EN 61439-3

IP rating BS EN 60529 (internal) 2XB 2XB

Page 17: Ready to install€¦ · 8 Domae consumer units - dimensions & technical data Insulated units Reference number No. of ways Height (mm) Width (mm) Depth (mm) DOM2CU 2 240 189 127 DOM4CU

17

Qwikline ll - devices technical data

Qwikline ll - incoming devices

Referencenumber Description No. of

polesCurrentrating

Operatingvoltage (V)

Max. cablecap. mm2

Standardsapproval

Recommended tightening torque

SQO1100M Switch dis. 2 100A 230/240 50 BS EN 60947-3 3.5 N.m.

SQO1100L Terminal block 2 100A 230/240 50 – 3.5 N.m.

SQOE063030 RCCB 2 63A, 30mA 230/240 35 BS EN 61008 3.5 N.m.

SQOE063100 RCCB 2 63A, 100mA 230/240 35 BS EN 61008 3.5 N.m.

Note: All Qwikline II consumer units are supplied without incoming devices. Any incoming device may be installed at any incoming point, or busbar split in any Qwikline II consumer unit.

Requirements Standard units – 1 incoming device required.Split load units – 2 incoming devices required.

Dual incomer units – 2 incoming devices required.Multi tariff units – 3 incoming devices required.

Qwikline ll - outgoing devicesMiniature circuit breakers (B curve)

Reference number

Currentrating

Operatingvoltage (V)

Breaking cap.(Icn (kA))

Max. cablecap. mm2

Standardsapproval

Recommended tightening torque

SQO103EB6 3A 230/240 6 25 BS EN 60898 2 N.m.

SQO106EB6 6A 230/240 6 25 BS EN 60898 2 N.m.

SQO110EB6 10A 230/240 6 25 BS EN 60898 2 N.m.

SQO116EB6 16A 230/240 6 25 BS EN 60898 2 N.m.

SQO120EB6 20A 230/240 6 25 BS EN 60898 2 N.m.

SQO125EB6 25A 230/240 6 25 BS EN 60898 2 N.m.

SQO132EB6 32A 230/240 6 35 BS EN 60898 3.5 N.m.

SQO140EB6 40A 230/240 6 35 BS EN 60898 3.5 N.m.

SQO150EB6 50A 230/240 6 35 BS EN 60898 3.5 N.m.

SQO163EB6 63A 230/240 6 35 BS EN 60898 3.5 N.m.

Miniature circuit breakers (C curve)

Reference number

Currentrating

Operatingvoltage (V)

Breaking cap.(Icn (kA))

Max. cablecap. mm2

Standardsapproval

Recommended tightening torque

SQO103EC6 3A 230/240 6 25 BS EN 60898 2 N.m.

SQO106EC6 6A 230/240 6 25 BS EN 60898 2 N.m.

SQO110EC6 10A 230/240 6 25 BS EN 60898 2 N.m.

SQO116EC6 16A 230/240 6 25 BS EN 60898 2 N.m.

SQO120EC6 20A 230/240 6 25 BS EN 60898 2 N.m.

SQO125EC6 25A 230/240 6 25 BS EN 60898 2 N.m.

SQO132EC6 32A 230/240 6 35 BS EN 60898 3.5 N.m.

SQO140EC6 40A 230/240 6 35 BS EN 60898 3.5 N.m.

SQO150EC6 50A 230/240 6 35 BS EN 60898 3.5 N.m.

SQO163EC6 63A 230/240 6 35 BS EN 60898 3.5 N.m.

RCBO’s (B curve)

Reference number

Currentrating

Operatingvoltage (V)

Breaking cap.(Icn (kA))

Max. cablecap. mm2

Standardsapproval

Recommended tightening torque

SQOR106B03 6A, 30mA (AC class) 230/240 6 10 BS EN 61009 2 N.m.

SQOR110B03 10A,30mA (AC class) 230/240 6 10 BS EN 61009 2 N.m.

SQOR116B03 16A,30mA (AC class) 230/240 6 10 BS EN 61009 2 N.m.

SQOR120B03 20A,30mA (AC class) 230/240 6 10 BS EN 61009 2 N.m.

SQOR132B03 32A,30mA (AC class) 230/240 6 16 BS EN 61009 2 N.m.

SQOR145B03 45A,30mA (AC class) 230/240 6 16 BS EN 61009 2 N.m.

Page 18: Ready to install€¦ · 8 Domae consumer units - dimensions & technical data Insulated units Reference number No. of ways Height (mm) Width (mm) Depth (mm) DOM2CU 2 240 189 127 DOM4CU

18

> LoadCentre KQDistribution boards

Page 19: Ready to install€¦ · 8 Domae consumer units - dimensions & technical data Insulated units Reference number No. of ways Height (mm) Width (mm) Depth (mm) DOM2CU 2 240 189 127 DOM4CU

19

LoadCentre KQ - single phase A type distribution boards - 125A

Split load boards are designed for use with earth protection devices (RCD’s) on the secondary side and provide the user with additional protection for selected units.Notes * 2 incoming devices required for split load units. e.g. Switch and RCCB’s.Secondary incomer is a plug on device - see page 20.All devices are supplied separately.

The split metering board is supplied with 2 meters, an overall switch disconnector and individual switch disconnectors for lighting and power. Meters are direct connected with pulse output.

Standard type (excluding incomers)Referencenumber Number of SP ways

Dimensions (mm)Height Width Depth

SE125A6 6 270 266 127

SE125A8 8 270 321 127

SE125A12 12 270 376 127

SE125A16 16 270 456 127

SE125A24 24 500 376 127

Split load type* (excluding incomers)Referencenumber

Number of ways Dimensions (mm)Unprotected SP Protected RCD Height Width Depth

SE125A4SL6 4 6 270 376 127

SE125A5SL5 5 5 270 376 127

SE125A4SL8 4 8 270 456 127

SE125A6SL6 6 6 270 456 127

Split meter board (including incomers)Referencenumber

Number of ways Dimensions (mm)Lighting Power Height Width Depth

SEA12S12 12 12 484 470 139

Single phase A type distribution boards - 125An Manufactured and tested to BS EN 61439-3n Maximum busbar rating 125An Voltage rating 230/240V ACn External IP3X protection to BS EN 60529n Internal IP2XB protection to BS EN 60529 provided by permanent, non removable, factory fitted barriersn Shielded neutral barsn Cable knockouts on all sides for speed of installationn Earth bar capacity 25mm2

n Neutral bar capacity 25mm2

n Wide range of bolt-on incomers, Plug-On outgoersn All A boards accept DIN control products e.g. contactors, time clocks, in any unused outgoing way without adaptation

Page 20: Ready to install€¦ · 8 Domae consumer units - dimensions & technical data Insulated units Reference number No. of ways Height (mm) Width (mm) Depth (mm) DOM2CU 2 240 189 127 DOM4CU

20

LoadCentre KQ - single phase A type distribution boards - 125A

Type A LoadCentre KQ+ DIN incoming devicesReferencenumber

Device type

Current rating

Number of poles

Standard approval

Cable capacity mm2

SE125L2 Terminal block 125A 2 – 50

SE125SW2 Switch disconnector 125A 2 BS EN 60947-3 50

SED63032 RCCB 63A, 30mA 2 BS EN 61008 35

SED63102 RCCB 63A, 100mA 2 BS EN 61008 35

SED63302 RCCB 63A, 300mA 2 BS EN 61008 35

SED100032 RCCB 100A, 30mA 2 BS EN 61008 50

SED100102 RCCB 100A, 100mA 2 BS EN 61008 50

Plug on RCCB secondary incomers for split load A boardsReferencenumber

Device type

Current rating

Number of poles

Standard approval

Cable capacity mm2

SQOE063030 RCCB 63A, 30mA 2 BS EN 61008 35

SQOE063100 RCCB 63A, 100mA 2 BS EN 61008 35

SQOE100030 RCCB 100A, 30mA 2 BS EN 61008 50

SQOE100100S RCCB 100A, 100mA TD 2 BS EN 61008 50

SQOE100100 RCCB 100A, 100mA 2 BS EN 61008 50

SQOE100300 RCCB 100A, 300mA 2 BS EN 61008 50

125A A board accessoriesReferencenumber

Device type

SEK Barrel lock and 2 keys new square door catch

SQODNBP Blanking plate (5 poles)

SEPLMCB MCB padlock attachment (pk 10)

SEPLRCBO RCBO padlock attachment (pk 10)

SEPL Padlock

SEAE16 A type DIN rail extension enclosure (16 SP ways available)

SE1100L 100A lug unit single pole

SESDC Replacement door catch

SEBP25 Blank plate 25 x 5

Page 21: Ready to install€¦ · 8 Domae consumer units - dimensions & technical data Insulated units Reference number No. of ways Height (mm) Width (mm) Depth (mm) DOM2CU 2 240 189 127 DOM4CU

21

LoadCentre KQ - three phase B type distribution boards - 250A

Standard type (excluding incomers)Referencenumber Number of TP ways

Dimensions (mm)Height Width Depth

SE12B250 4 484 470 139

SE18B250 6 484 470 139

SE24B250 8 538 470 139

SE36B250 12 700 470 139

SE48B250 16 808 470 139

SE54B250 18 862 470 139

SE72B250 24 1024 470 139

Split load (excluding incomers)Referencenumber

Number ofTP ways

Referencenumber

Number ofTP ways

SE12B250 4 SE12B250 4

SE18B250 6 SE18B250 6

SE24B250 8 SE24B250 8

SE36B250 12 SE36B250 12

SE48B250 16 SE48B250 16

SE54B250 18 SE54B250 18

SE72B250 24 SE72B250 24

Extra service units 125A (combination of a standard board and DIN rail enclosure)Referencenumber

Number of TPbusbar ways

Referencenumber

Numberof rows

Number of modules

Dimensions (mm)Height Width Depth

SE12B250 4 SE17BES 1 17 270 470 139

SE18B250 6 SE12B2D 2 34 484 470 139

SE24B250 8 SE18B2D 2 34 538 470 139

SE36B250 12 SE36B3D 3 51 700 470 139

SE48B250 16 SE54B4D 4 68 808 470 139

SE54B250 18

SE72B250 24

Three phase B type distribution boards - 250An Manufactured and tested to BS EN 61439-3n Maximum busbar rating 250An Voltage Rating 400/415V ACn External IP3X protection to BS EN 60529n IP2XB finger safe with door and cover removed to BS EN 60529, provided by permanent, non removable, factory fitted barriersn Fully shielded neutral barsn Earth and neutral bar cable capacity 25mm2

n All incoming connections are the same length i.e. 4 pole configurationn Range of integral incomers for all applications including lugs, switches, RCCB’s and MCCB’sn Outgoing MCB’s available up to 63A B, C or D curvesn 18mm wide RCBO available, minimising use of outgoing waysn Plug-On outgoers for speed of installation and guaranteed connectionn All B boards accept DIN control products (timers, contactors) in any unused outgoing way without adaptationn Control wiring cable way integrated to moulding

} {+

} {+

Split load joining kit for mechanical connection SEJK. 63A tapoff to feed protected board (including joining kit) SE63SLK.

Extra service units are designed for application using numerous control products and RCCB’s.These units provide a professional finish while economising on ease and speed of installation.

Page 22: Ready to install€¦ · 8 Domae consumer units - dimensions & technical data Insulated units Reference number No. of ways Height (mm) Width (mm) Depth (mm) DOM2CU 2 240 189 127 DOM4CU

22

LoadCentre KQ - three phase B type distribution boards

125A boards are supplied with a switch disconnector2 x PM750 meters included (pulsed and ModBus output)

250A boards require a switch disconnector to be added2 x multi function meter included (pulsed and ModBus output)

Split metering board 125AReferencenumber

Number of TP waysSection 1 Section 2

RatingA

Dimensions (mm)Height Width Depth

SEB36S24125 12 8 125 1290 470 139

SEB42S18125 14 6 125 1290 470 139

SEB48S12125 16 4 125 1290 470 139

Split metering board 250AReferencenumber

Number of TP waysSection 1 Section 2

RatingA

Dimensions (mm)Height Width Depth

SEB36S24250 12 8 250 1290 470 139

SEB42S18250 14 6 250 1290 470 139

SEB48S12250 16 4 250 1290 470 139

L <25mmd <10mmØ >8mm

250A type B LoadCentre KQ incoming devicesReferencenumber

Device type

Current rating

Number of poles

Standard approval

Cable capacity mm2

SE250L4P Terminal block 250A 4 – 185

SE160SW3L Switch disconnector 160A 3+N BS EN 60947-3 95

SE200SW3L Switch disconnector 200A 3+N BS EN 60947-3 185

SE250SW3L Switch disconnector 250A 3+N BS EN 60947-3 185

SE160SW4 Switch disconnector 160A 4 BS EN 60947-3 95

SE200SW4 Switch disconnector 200A 4 BS EN 60947-3 185

SE250SW4 Switch disconnector 250A 4 BS EN 60947-3 185

SE100MCCB3L MCCB 100A 3+N BS EN 60947-2 95

SE160MCCB3L MCCB 160A 3+N BS EN 60947-2 95

SE200MCCB3L MCCB 200A 3+N BS EN 60947-2 185

SE250MCCB3L MCCB 250A 3+N BS EN 60947-2 185

SE160RCD RCCB 160A Adjustable30mA - 10A

4 BS EN 61008 95

125A type B LoadCentre KQ incoming devicesReferencenumber

Device type

Current rating

Number of poles

Standard approval

Cable capacity mm2

SE125L4 Terminal block 125A 4 – 50

SE125SW4 Switch disconnector 125A 4 BS EN 60947-3 50

SE125SW3L Switch disconnector 125A 3+N lug BS EN 60947-3 50

SED80034 RCCB 80A, 30mA 4 BS EN 61008 35

SED100304 RCCB 100A, 300mA 4 BS EN 61008 50

SED100304S RCCB 100A, 300mA TD 4 BS EN 61008 50

SECSW100 Contactor + switch 100A 4 BS EN 60439 50

Note For a wider range of RCCB incomers see the RSD offer on page 25

Note Supplied with 400mm extension box

Metering kitReferencenumber Description

SE250MET Multi function metering kit for LoadCentre KQ 3 phase B type distribution boards Components: Multi function meter provides V, A, Power factor kW/h, kVA/h. Three current transformers. Three single pole MCB’sVoltage rating: 415V nominal, 455V maximum. 3 phase 4 wire 50-60 HzOutput: Pulse output contact is standard + ModBus

Page 23: Ready to install€¦ · 8 Domae consumer units - dimensions & technical data Insulated units Reference number No. of ways Height (mm) Width (mm) Depth (mm) DOM2CU 2 240 189 127 DOM4CU

23

B board accessoriesReferencenumber

Device type

SESJK Side joining kit

SEJK Top/bottom joining kit

SE63SLK 63A Top off or split load

SEK Barrel lock and 2 keys for catch

SEK33 Spare keys for above

W29370 MCCB locking attachment

SE125SPP 125A single phasing kit for use with RCD and switch incomers

SE250SPP 250A single phasing kit

SQODNBP Blanking plate (5 poles)

SEPLMCB MCB padlock attachment (pk 10)

SEPLRCBO RCBO padlock attachment (pk 10)

SEPL Padlock

WALLET Circuit directory and wallet (pack of 10)

SEPD Padlocking door kit

SEBES Plain extension box

SE1100L 100A lug unit single pole

SEGPKO Spare gland plate with knockouts

SEGP Spare gland plate

SECE12T Clean earth 12 terminals

SECE24T Clean earth 24 terminals

SE72BL Spare way label 72 ways

SEEXGP Spare gland plate for extension box

SESDC Spare door catch

SEBNC Neutral terminal cover

SEBFCF Spare cover fixing (24)

SEBEK1 Extra earth bar 14 hole

SEBEK2 Extra earth bar 20 hole

SEBEK3 Extra earth bar 26 hole

LoadCentre KQ - three phase B type distribution boards

Page 24: Ready to install€¦ · 8 Domae consumer units - dimensions & technical data Insulated units Reference number No. of ways Height (mm) Width (mm) Depth (mm) DOM2CU 2 240 189 127 DOM4CU

24

LoadCentre KQ - KQ miniature circuit breakers (MCB’s)

Type B (magnetic setting 3-5 in)For resistive and light reactive loads, e.g. heating, incandescent lighting etc Reference numbers Current

rating (Icn*)Cable capacity mm21 pole 2 pole 3 pole

SE10B103 – – 3A 25SE10B106 – – 6A 25SE10B110 – – 10A 25SE10B116 – – 16A 25SE10B120 – – 20A 25SE10B125 – – 25A 25SE10B132 – – 32A 35SE10B140 – – 40A 35SE10B150 – – 50A 35SE10B163 – – 63A 35

Type C (magnetic setting 5-10 in)For moderately light reactive loads, e.g. fluorescent lighting Reference numbers Current

rating (Icn*)Cable capacity mm21 pole 2 pole 3 pole

SE10C106 SE10C206 SE10C306 6A 25SE10C110 SE10C210 SE10C310 10A 25SE10C116 SE10C216 SE10C316 16A 25SE10C120 SE10C220 SE10C320 20A 25SE10C125 SE10C225 SE10C325 25A 25SE10C132 SE10C232 SE10C332 32A 35SE10C140 SE10C240 SE10C340 40A 35SE10C150 SE10C250 SE10C350 50A 35SE10C163 SE10C263 SE10C363 63A 35

Type D (magnetic setting 10-14 in)For highly reactive loads, e.g. motors, pumps and transformers Reference numbers Current

rating (Icn*)Cable capacity mm21 pole 2 pole 3 pole

SE10D106 SE10D206 SE10D306 6A 25SE10D110 SE10D210 SE10D310 10A 25SE10D116 SE10D216 SE10D316 16A 25SE10D120 SE10D220 SE10D320 20A 25SE10D125 SE10D225 SE10D325 25A 25SE10D132 SE10D232 SE10D332 32A 35SE10D140 SE10D240 SE10D340 40A 35SE10D150 SE10D250 SE10D350 50A 35SE10D163 SE10D263 SE10D363 63A 35

DIN rail mounted 80/100A MCBSuitable for use in extension enclosures or extra service unitsReference number Description Terminal capacity Modular size

KQ10C3100 MCB 3P 100A Type C 50 4.5KQ10C380 MCB 3P 80A Type C 50 4.5

KQ miniature circuit breakers (MCB’s)n Manufactured and tested to BS EN 60898n 10kA breaking capacity 15kA to BS EN 60947-2n Let through energy classification of 3 (lowest let through energy giving best cable protection classification)n Positive contact indication (guaranteed on/off indication)n Trip free mechanism operates even when the toggle is locked onn Lockable in the ON or OFF positionn Speed of connection of Plug-On devices - guaranteed connection Plug-On devicesn For use in LoadCentre KQ A and B boards

Must be used with SE17BES enclosure and 3 x SE1100L.

Page 25: Ready to install€¦ · 8 Domae consumer units - dimensions & technical data Insulated units Reference number No. of ways Height (mm) Width (mm) Depth (mm) DOM2CU 2 240 189 127 DOM4CU

25

LoadCentre KQ - residual current circuit breakers (RCBO’s)

AplicationsRCBO’s are available with various earth leakage sensitivities to suit numerous applications including 10mA devices for protection of sensitive machine/equipment, 30mA devices which are generally used for personnel protection and 100mA for meeting high earth loop impedance levels.

RCBO’s should be carefully selected for the relevant application.

Residual current circuit breakers (RCBO’s)n Manufactured and tested to BS EN 61009n 10kA breaking capacityn Let through energy classification of 3 (lowest let through energy giving best cable protection classification)n Positive contact indication on toggle (guaranteed on/off indication)n Trip free MCB mechanismn Lockable in the ON or OFF positionn Automatic trip on loss of neutraln Automatic protection against reverse polarityn Type B and C characteristicsn Operating voltage 150 - 230Vacn 6 - 45A; 10, 30 and 100mA sensitivitiesn AC class sensitivityn For use in KQ LoadCentre A and B boardsn One single pole way occupied in a distribution board ideal for retrofitting earth fault protectionn Cable capacity 16mm2

n Speed of connection of Plug-On devicesn Assured system integrity, no other devices fit KQ boards

Residual current circuit breakersReferencenumber

Current rating

Tripping curve Sensitivity Cable capacity

mm2

SEE106B03 6A B 30mA 16

SEE110B03 10A B 30mA 16

SEE116B03 16A B 30mA 16

SEE120B03 20A B 30mA 16

SEE125B03 25A B 30mA 16

SEE132B03 32A B 30mA 16

SEE140B03 40A B 30mA 16

SEE145B03 45A B 30mA 16

SEE106C01 6A C 10mA 16

SEE110C01 10A C 10mA 16

SEE116C01 16A C 10mA 16

SEE120C01 20A C 10mA 16

SEE125C01 25A C 10mA 16

SEE132C01 32A C 10mA 16

SEE140C01 40A C 10mA 16

SEE145C01 45A C 10mA 16

SEE106C03 6A C 30mA 16

SEE110C03 10A C 30mA 16

SEE116C03 16A C 30mA 16

SEE120C03 20A C 30mA 16

SEE125C03 25A C 30mA 16

SEE132C03 32A C 30mA 16

SEE140C03 40A C 30mA 16

SEE145C03 45A C 30mA 16

SEE106C10 6A C 100mA 16

SEE110C10 10A C 100mA 16

SEE116C10 16A C 100mA 16

SEE120C10 20A C 100mA 16

SEE125C10 25A C 100mA 16

SEE132C10 32A C 100mA 16

SEE140C10 40A C 100mA 16

SEE145C10 45A C 100mA 16

Page 26: Ready to install€¦ · 8 Domae consumer units - dimensions & technical data Insulated units Reference number No. of ways Height (mm) Width (mm) Depth (mm) DOM2CU 2 240 189 127 DOM4CU

26

LoadCentre KQ - residual current circuit breakers (RCCB’s)

Residual current circuit breakers (RCCB’s)All residual current circuit breakers are suitable for use as main incomers in LoadCentre KQ distribution boards.n Comply with BS EN 61008. Specification for residual current operated circuit breakersn Rated voltage 240/415V AC 50/60 Hzn Test button enables RCCB to be tested periodicallyn 30mA device suitable for use as additional protection on final sub circuits e.g. equipment outside equipotential zone or items requiring 2/4 pole protection i.e. switched neutral applications

Residual current circuit breakersReferencenumber Description

Cable capacity mm2

Dimensions (mm) Weight (Kg)Height Width Depth

SED25032 25A RCCB 30mA trip 2 pole 35 81 36 75 0.227

SED25302 25A RCCB 300mA trip 2 pole 35 81 36 75 0.227

SED40032 40A RCCB 30mA trip 2 pole 3 35 81 36 75 0.227

SED40102 40A RCCB 100mA trip 2 pole 35 81 36 75 0.227

SED40302 40A RCCB 300mA trip 2 pole 35 81 36 75 0.227

SED63032 63A RCCB 30mA trip 2 pole 3 35 81 36 75 0.227

SED63102 63A RCCB 100mA trip 2 pole 35 81 36 75 0.227

SED63302 63A RCCB 300mA trip 2 pole 35 81 36 75 0.227

SED80032 80A RCCB 30mA trip 2 pole 50 81 36 75 0.227

SED100032 100A RCCB 30mA trip 2 pole 50 81 36 75 0.227

SED100102 100A RCCB 100mA trip 2 pole 50 81 36 75 0.227

SED25034 25A RCCB 30mA trip 4 pole 35 81 72 75 0.428

SED25104 25A RCCB 100mA trip 4 pole 35 81 72 75 0.428

SED25304 25A RCCB 300mA trip 4 pole 35 81 72 75 0.428

SED40034 40A RCCB 30mA trip 4 pole 35 81 72 75 0.428

SED40104 40A RCCB 100mA trip 4 pole 35 81 72 75 0.428

SED40304 40A RCCB 300mA trip 4 pole 35 81 72 75 0.428

SED63034 63A RCCB 30mA trip 4 pole 35 81 72 75 0.428

SED63104 63A RCCB 100mA trip 4 pole 35 81 72 75 0.428

SED63304 63A RCCB 300mA trip 4 pole 35 81 72 75 0.428

SED80034 80A RCCB 30mA trip 4 pole 35 81 72 75 0.500

SED100304 100A RCCB 300mA trip 4 pole 50 81 72 75 0.500

SED100304S 100A RCCB 300mA trip 4 pole + TD 50 81 72 75 0.500

Individual RCCB insulated enclosureReferencenumber Description

Dimensions (mm) Weight (Kg)Height Width Depth

RSD4IP54 4 x 18mm module IP54 protection 200 110 112 0.35

RSD insulated enclosures are also suitable for any DIN rail mounted product including time clocks, timers, contactors, switches and relays.

Page 27: Ready to install€¦ · 8 Domae consumer units - dimensions & technical data Insulated units Reference number No. of ways Height (mm) Width (mm) Depth (mm) DOM2CU 2 240 189 127 DOM4CU

27

LoadCentre KQ - extension enclosures

Extension enclosuresLoadCentre KQ enclosures are available for applications where matching extension boxes are required to house system extensions or stand alone control systems.There are two configurations, plain enclosures with door, enclosures with DIN rail, door and front cover assembly.

Steel enclosures with plain cover and doorReferencenumber

Dimensions (mm)Height Width Depth

SE12BCD 484 470 139

SE18BCD 538 470 139

SE36BCD 700 470 139

SE54BCD 808 470 139

Steel enclosures with DIN rails and a front cover assembly and doorReferencenumber

Numberof rows

Total numberof SP modules

Dimensions (mm)Height Width Depth

SE12B2D 2 34 484 470 139

SE18B2D 2 34 538 470 139

SE36B3D 3 51 700 470 139

SE54B4D 4 68 808 470 139

Steel enclosure with 1 row of DIN rails and a front cover assembly and doorReferencenumber

Numberof rows

Total numberof SP modules

Dimensions (mm)Height Width Depth

SE172BES 1 17 270 470 139

Steel enclosureReferencenumber

Numberof rows

Total numberof SP modules

Dimensions (mm)Height Width Depth

SEBES – – 270 470 124

Page 28: Ready to install€¦ · 8 Domae consumer units - dimensions & technical data Insulated units Reference number No. of ways Height (mm) Width (mm) Depth (mm) DOM2CU 2 240 189 127 DOM4CU

28

> PanelboardsI-Line MCCB

28

Page 29: Ready to install€¦ · 8 Domae consumer units - dimensions & technical data Insulated units Reference number No. of ways Height (mm) Width (mm) Depth (mm) DOM2CU 2 240 189 127 DOM4CU

29

Panelboards - I-Line MCCB panelboards Size 1 250A

Step 1 Select panelboard required

Description ModulesReference number250A

6 triple pole outgoing ways 18 MP25061

12 triple pole outgoing ways 36 MP250121

Step 2 Select incoming device250A Reference number

250A 36kA triple pole MCCB CNXAE34250

250A 50kA triple pole MCCB CHXAE34250

100A automatic switch disconnector (isolator) CNXAE34000S10

160A automatic switch disconnector (isolator) CNAXE34000S15

250A automatic switch disconnector (isolator) CNAXE34000S25

225A plug on lug unit SL225

Step 3 Select outgoing devicesSingle and double pole MCCB’s are phase dedicated. To obtain correct reference add suffix as below example: 40A SP MCCB to fit L3 will be SFA1040C

Size 1 250/400A panelboardsn Single sided to give best possible space utilisationn Incomers can be mounted at top or bottom of the panelboardn Ample cabling spacen L-Line Busbar Systemn Degree of protection IP3Xn Hinged lift off cable way covern MCCB separation to form 3b Type 2 BS EN 60439-1n Fully rated earth and neutral barsn Simple orderingn Removable top and bottom gland platesn Busbar rating 50ka for 1s

MCCB

16-100A 25kA Single Pole (1 Mod) Double Pole (2 Mod)

L1 L2 L3 L1/L2 L2/L3 L1/L3

Suffix Suffix

16A SFA1016 SFA2016

20A SFA1020 SFA2020

32A SFA1032 SFA2032

40A SFA1040 A B C SFA2040 AB BC AC

50A SFA1050 SFA2050

63A SFA1063 SFA2063

80A SFA1080 SFA2080

100A SFA1100 SFA2100

Page 30: Ready to install€¦ · 8 Domae consumer units - dimensions & technical data Insulated units Reference number No. of ways Height (mm) Width (mm) Depth (mm) DOM2CU 2 240 189 127 DOM4CU

30

Panelboards - I-Line MCCB panelboards Size 1 250A

Step 4 Select meteringThe I-Line Panelboard product range has being enhanced to include the facility to meter incoming and outgoing circuits. This enables contractors to easily and simply meet the requirements of Part L2a of the Building Regulations. These metering kits allow great flexibility in the choice of meter and also in the configuration of the boards.

Incoming metering This metering kit is for the incoming supply to the board. It comprises an extension box that can be fitted to the top or the bottom of a standard board. This box contains a three-phase block current transformer, fuses for the voltage supply and a PM750 multi-function meter. Because the main incoming cables pass through this enclosure it is not suitable for a retrofit. The kit comes complete: no other parts are required to install this metering kit.

Reference number Incoming Metering

MPME2501 250A top/bottom metering extension box

Step 3 Select outgoing devices cont.Triple pole (3 mods) Additional

tunnelterminals

Acceptablecablesize

25kA 36kA 50kA Reference No.

16A CDXAE34016 CNXAE34016 CHXAE34016

25A CDXAE34025 CNXAE34025 CHXAE34025

32A CDXAE34032 CNXAE34032 CHXAE34032

40A CDXAE34040 CNXAE34040 CHXAE34040 LV42922 1.5-95mm

50A CDXAE34050 CNXAE34050 CHXAE34050

63A CDXAE34063 CNXAE34063 CHXAE34063

80A CDXAE34080 CNXAE34080 CHXAE34080

100A CDXAE34100 CNXAE34100 CHXAE34100

125A CNXAE34125 CHXAE34125

160A CNXAE34160 CHXAE34160

200A CNXAE34200 CHXAE34200 LV429259 95-185mm

250A CNXAE34250 CHXAE34250 LV429259

160A electronic CNXAE34160E20 LV429242 1.5-95mm

250A electronic CNXAE250E20 LV425252 95-185mm

Page 31: Ready to install€¦ · 8 Domae consumer units - dimensions & technical data Insulated units Reference number No. of ways Height (mm) Width (mm) Depth (mm) DOM2CU 2 240 189 127 DOM4CU

31

Panelboards - I-Line MCCB panelboards Size 1 250A

Step 5 Select accessoriesPanelboard MP25061 MP250121

Blanking plates for all unused ways

Single pole HNM1BL HNM1BL

Triple pole HNM4BL HNM4BL

Side extension box

508mm wide EXMS20411 EXMS22051

Top / bottom extension box

226mm high EXS91 EXS91

MCCB Incomer padlocking device

250A 29370 29370

Door lock QOKS1 QOKS1

2 Spare keys KQK33 KQK33

Terminal shields x 2 See page 18

Plug-on metering kit for incoming supply - occupies 4 modules

Analogue, voltmeter & ammeter

MP250INS MP250INS

* Digital, multi function meter

MP250kW MP250kW

Weight in kg 46 76

Overall dimensions H x W x D

1041x508x184 1727x508x184

Fixing centres 800 1486

* See page 44 for outgoing metering

Page 32: Ready to install€¦ · 8 Domae consumer units - dimensions & technical data Insulated units Reference number No. of ways Height (mm) Width (mm) Depth (mm) DOM2CU 2 240 189 127 DOM4CU

32

Panelboards - I-Line MCCB panelboards Size 1 400A

Step 1 Select panelboard required

Description ModulesReference number400A

4 triple pole outgoing ways 12 MP40041

7 triple pole outgoing ways 21 MP40071

12 triple pole outgoing ways 36 MP400121

Size 1 400A panelboardsn Single sided to give best possible space utilisationn Incomers cabe mounted at top or bottom of the panelboardn Ample cabling spacen I-Line busbarn Degree of protection IP3Xn Hinged lift off cable way covern MCCB separation to form 3b Type 2 BS EN 60439-1n Fully rated earth and neutral barsn Simple orderingn Removable top and bottom gland platesn Busbar rating 50ka for 1s

Step 2 Select incoming device250A Reference number

250A 36kA triple pole MCCB CNXAE34250

250A 50kA triple pole MCCB CHAXE34250

100A automatic switch disconnector (isolator) CNAXE34000S10

160A automatic switch disconnector (isolator) CNAXE34000S15

250A automatic switch disconnector (isolator) CNAXE34000S25

225A plug on lug unit SL225

400A*

400A 36kA triple pole MCCB SLA3400

400A automatic switch disconnector (isolator) SLA3000M

*Trim, required when 250A incomer fitted TKA4, TKA7, TKA12

Step 3 Select outgoing devicesSingle and double pole MCCB’s are phase dedicated. To obtain correct reference add suffix as below example: 40A SP MCCB to fit L3 will be SFA1040C

MCCB

16-100A 25kA Single Pole (1 Mod) Double Pole (2 Mod)

L1 L2 L3 L1/L2 L2/L3 L1/L3

Suffix Suffix

16A SFA1016 SFA2016

20A SFA1020 SFA2020

32A SFA1032 SFA2032

40A SFA1040 A B C SFA2040 AB BC AC

50A SFA1050 SFA2050

63A SFA1063 SFA2063

80A SFA1080 SFA2080

100A SFA1100 SFA2100

Page 33: Ready to install€¦ · 8 Domae consumer units - dimensions & technical data Insulated units Reference number No. of ways Height (mm) Width (mm) Depth (mm) DOM2CU 2 240 189 127 DOM4CU

33

Panelboards - I-Line MCCB panelboards Size 1 400A

Step 3 Select outgoing devices cont.Triple pole (3 mods) Additional

tunnel terminalsAcceptablecable size

25kA 36kA 50kA Reference No.

16A CDXAE34016 CNXAE34016 CHXAE34016

25A CDXAE34025 CNXAE34025 CHXAE34025

32A CDXAE34032 CNXAE34032 CHXAE34032

40A CDXAE34040 CNXAE34040 CHXAE34040 LV429242 1.5-95mm

50A CDXAE34050 CNXAE34050 CHXAE34050

63A CDXAE34063 CNXAE34063 CHXAE34063

80A CDXAE34080 CNXAE34080 CHXAE34080

100A CDXAE34100 CNXAE34100 CHXAE34100

125A CNXAE34125 CHXAE34125

160A CNXAE34160 CHXAE34160

200A CNXAE34200 CHXAE34200 LV429259 95-185mm

250A CNXAE34250 CHXAE34250 LV429259

160A electronic CNXAE34160E20 LV429242 1.5-95mm

250A electronic CNXAE34250E20 LV429259 95-185mm

Step 4 Select meteringThe I-Line Panelboard product range has being enhanced to include the facility to meter incoming and outgoing circuits. This enables contractors to easily and simply meet the requirements of Part L2a of the Building Regulations. These metering kits allow great flexibility in the choice of meter and also in the configuration of the boards.

Outgoing metering A standard board can be adapted to meter the incoming supply and some or all of the outgoing circuits by the addition of three components. These components are:

A. Select metering kit 1 Metering kit. This contains a replacement wireway door with 96 sq cutouts for the number of outgoing ways of the board plus one. This additional cutout is to meter the incoming supply as required. Blanking plates are supplied for unused meter positions. One door kit per board.

Size 1 400AReference number

MPMK104 4 way I-Line metering kit

MPMK107 7 way I-Line metering kit

MPMK112 12 way I-Line metering kit

B. Select metering CT set for each outgoing MCCB to be monitored2 Current transformer kit. One kit for each circuit to be measured. The kit will comprise a three phase CT block, mounting plate and cable loom. The CT blocks fit to the breakers. The CT size and ratio matches the breaker.

Reference number CT ratio

MPCT125 C frame breaker 125/5

MPCT150 C frame breaker 150/5

MPCT250 C frame breaker 250/5

C. Select PowerLogic meters for each circuit to be measured

Reference number

PM700 Multi function PowerMeter

PM700P Multi function PowerMeter with pulse outputs

PM710 Multi function PowerMeter with Modbus RS485 output

PM750 Same functions as the PM710, plus two digital inputs, one digital output, alarms and signed power factor. The PM750 digital output can be simply configured as a kWh pulse output

Page 34: Ready to install€¦ · 8 Domae consumer units - dimensions & technical data Insulated units Reference number No. of ways Height (mm) Width (mm) Depth (mm) DOM2CU 2 240 189 127 DOM4CU

34

Panelboards - I-Line MCCB panelboards Size 1 400A

Step 5 Select accessoriesPanelboard MP40041 MP40071 MP400121

Blanking plates for all unused ways

Single pole HNM1BL HNM1BL HNM1BL

Triple pole HNM4BL HNM4BL HNM4BL

Blanking plates for every MCCB way when one or more PF devices fitted

Single pole HNF1BL HNF1BL HNF1BL

Triple pole HNF4BL HNF4BL HNF4BL

Trim, required when 250A incomer fitted TKA4 TKA7 TKA12

Side extension box

508mm wide

550mm wide EXMS827 EXMS1170 EXMS1742

Top / bottom extension box

226mm high

379mm high EXS151 EXS151 EXS151

MCCB Incomer padlocking device

250A 29370 29370 29370

400A HPALM HPALM HPALM

Door lock QOKS1 QOKS1 QOKS1

2 Spare keys KQK33 KQK33 KQK33

Terminal shields x 2 See page 42

Plug-on metering kit for incoming supply - occupies 4 modules

Analogue, voltmeter & ammeter MP400INS MP400INS MP400INS

* Digital, multi function meter MP400kW MP400kW MP400kW

Weight in kg 44 74 100

Overall dimensions H x W x D 827x680x258 1170x680x258 1742x680x258

Fixing centres 533 876 1448

* See page 44 for outgoing metering

Page 35: Ready to install€¦ · 8 Domae consumer units - dimensions & technical data Insulated units Reference number No. of ways Height (mm) Width (mm) Depth (mm) DOM2CU 2 240 189 127 DOM4CU

35

Panelboards - I-Line MCCB panelboards Size 2 630A

Step 1 Select panelboard required

Description ModulesReference number630A

6 triple pole outgoing ways 9+9 MP63062

10 triple pole outgoing ways 15+15 MP630102

14 triple pole outgoing ways 21+21 MP630142

18 triple pole outgoing ways 27+27 MP630182

Size 2 630A panelboardsn Degree of protection IP3Xn Door lock fitted as standardn Ample cabling spacen I-Line busbarn Removable neutral linkn Hinged lift off cable way coversn MCCB separation to form 3b Type 2 BS EN 60439-1n Fully rated earth and neutral barsn Removable top and bottom gland platesn Simple orderingn Maximum outgoers 250An Busbar rating 50ka for 1s

Step 2 Select incoming deviceReference number

250A 36kA triple pole MCCB SLA3250

400A 36kA triple pole MCCB SLA3400

400A automatic switch disconnector (isolator) SLA3000M

600A 50kA triple pole MCCB PJA36060CU31A

600A automatic switch disconnector (isolator) PJA36000S60

630A main lugs kit ML630

Step 3 Select outgoing devicesSingle and double pole MCCB ’s are phase dedicated. To obtain correct reference add suffix as below example: 40A SP MCCB to fit L3 will be SFA1040CC

MCCB

16-100A 25kA Single Pole (1 Mod) Double Pole (2 Mod)

L1 L2 L3 L1/L2 L2/L3 L1/L3

Suffix Suffix

16A SFA1016 SFA2016

20A SFA1020 SFA2020

32A SFA1032 SFA2032

40A SFA1040 A B C SFA2040 AB BC AC

50A SFA1050 SFA2050

63A SFA1063 SFA2063

80A SFA1080 SFA2080

100A SFA1100 SFA2100

Page 36: Ready to install€¦ · 8 Domae consumer units - dimensions & technical data Insulated units Reference number No. of ways Height (mm) Width (mm) Depth (mm) DOM2CU 2 240 189 127 DOM4CU

36

Panelboards - I-Line MCCB panelboards Size 2 630A

Step 3 Select outgoing devices cont.Triple pole (3 mods) Additional

tunnelterminals

Acceptablecablesize

25kA 36kA 50kA Reference No.

16A CDXAE34016 CNXAE34016 CHXAE34016

25A CDXAE34025 CNXAE34025 CHXAE34025

32A CDXAE34032 CNXAE34032 CHXAE34032

40A CDXAE34040 CNXAE34040 CHXAE34040 LV42922 1.5-95mm

50A CDXAE34050 CNXAE34050 CHXAE34050

63A CDXAE34063 CNXAE34063 CHXAE34063

80A CDXAE34080 CNXAE34080 CHXAE34080

100A CDXAE34100 CNXAE34100 CHXAE34100

125A CNXAE34125 CHXAE34125

160A CNXAE34160 CHXAE34160

200A CNXAE34200 CHXAE34200 LV429259 95-185mm

250A CNXAE34250 CHXAE34250 LV429259

160A electronic CNXAE34160E20 LV429242 1.5-95mm

250A electronic CNXAE34250E20 LV425252 95-185mm

Page 37: Ready to install€¦ · 8 Domae consumer units - dimensions & technical data Insulated units Reference number No. of ways Height (mm) Width (mm) Depth (mm) DOM2CU 2 240 189 127 DOM4CU

37

Panelboards - I-Line MCCB panelboards Size 2 630A

Step 4 Select meteringThe I-Line Panelboard product range has being enhanced to include the facility to meter incoming and outgoing circuits. This enables contractors to easily and simply meet the requirements of Part L2a of the Building Regulations. These metering kits allow great flexibility in the choice of meter and also in the configuration of the boards.

A standard board can be adapted to meter the incoming supply and some or all of the outgoing circuits by the addition of three components. These components are:

A. Select metering kit 1 Metering kit. This contains a replacement wireway door with 96 sq cutouts for the number of outgoing ways of the board plus one. This additional cutout is to meter the incoming supply as required. Blanking plates are supplied for unused meter positions. One door kit per board.

Size 2 630AReference number

MPMK206 6 way I-Line metering kit

MPMK210 10 way I-Line metering kit

MPMK214 14 way I-Line metering kit

MPMK218 18 way I-Line metering kit

B. Select metering CT set for each outgoing MCCB to be monitored2 Current transformer kit. One kit for each circuit to be measured. The kit will comprise a three phase CT block, mounting plate and cable loom. The CT blocks fit to the breakers. The CT size and ratio matches the breaker.

Reference number CT ratio

MPCT125 C frame breaker 125/5

MPCT150 C frame breaker 150/5

MPCT250 C frame breaker 250/5

MPCT400 L frame breaker 400/5

MPCT600 M & P frame breakers 600/5

C. Select PowerLogic meters for each circuit to be measured

Reference number

PM700 Multi function PowerMeter

PM700P Multi function PowerMeter with pulse outputs

PM710 Multi function PowerMeter with Modbus RS485 output

PM750 Same functions as the PM710, plus two digital inputs, one digital output, alarms and signed power factor. The PM750 digital output can be simply configured as a kWh pulse output

Page 38: Ready to install€¦ · 8 Domae consumer units - dimensions & technical data Insulated units Reference number No. of ways Height (mm) Width (mm) Depth (mm) DOM2CU 2 240 189 127 DOM4CU

38

Panelboards - I-Line MCCB panelboards Size 2 630A

Step 5 Select accessoriesPanelboard MP63062 MP630102 MP630142 MP630182

Blanking plates for all unused ways

Single pole HNM1BL HNM1BL HNM1BL HNM1BL

Triple pole HNM4BL HNM4BL HNM4BL HNM4BL

Side extension box 550mm wide EXMS53 EXMS62 EXMS71 EXMS80

Top / bottom extension box 226mm high EXS29 EXS29 EXS29 EXS29

Corner unit, to complete enclosure when top/bottom and side extension are both fitted

MSIL636 MSIL636 MSIL636 MSIL636

Door lock

2 Spare keys KQK33 KQK33 KQK33 KQK33

Terminal shields x 2 See page 42

Integral metering kit for incoming supply

Analogue, voltmeter & ammeter

400A 400INSKN 400INSKN 400INSKN 400INSKN

630A 600INSKN 600INSKN 600INSKN 600INSKN

* Digital, multi function meter

400A 400kW 400kW 400kW 400kW

630A 630kW 630kW 630kW 630kW

Weight in kg 112 128 145 164

Overall dimensions H x W x D 1350x1100x258 1579x1100x258 1807x1100x258 2036x1100x258

* See page 44 for outgoing metering

Page 39: Ready to install€¦ · 8 Domae consumer units - dimensions & technical data Insulated units Reference number No. of ways Height (mm) Width (mm) Depth (mm) DOM2CU 2 240 189 127 DOM4CU

39

Panelboards 800A to 1600A Please consult usTel 0870 608 8 608

Page 40: Ready to install€¦ · 8 Domae consumer units - dimensions & technical data Insulated units Reference number No. of ways Height (mm) Width (mm) Depth (mm) DOM2CU 2 240 189 127 DOM4CU

40

Panelboards - I-Line MCCB panelboards Panelboard accessories

Reference number

1 module way: HNM1BL pack quantity 1

3 module way: HNM4BL pack quantity 1

Reference number

Door lock QOKS1 supplied with 2 keys.

Panelboard size 2 is supplied with a door lock as standard. If replacement locks are required, order reference QOKSB. Set of 2 spare keysKQK 33

Blanking platesSuitable for all sizes of panelboard, blanking plates must be fitted in all unoccupied outgoing ways to maintain appropriate busbar shrouding.

Panelboards are supplied without blanking plates.

Door lockAll keys are identical.For size 1 panelboard, field installable.

Side extension boxesSupplied with hinged door, side extension boxes may be used to provide additional wiring space or fitting of control equipment or Qwikline II MCB distribution boards.

Side extension boxes can be fitted to either side of the panelboard and may be coupled together to form larger units.

Box width250A boards: 508mm. 400A, 630A boards: 550mm.

Top/bottom extension boxesSupplied with a flat front plate the extension box provides additional cable spreading space.

Box heights250A: 226mm. 400A: 380mm.630A: 226mm.

Corner units are available to ‘square off’ a board when a side and a top/bottom extension box are fitted.

Page 41: Ready to install€¦ · 8 Domae consumer units - dimensions & technical data Insulated units Reference number No. of ways Height (mm) Width (mm) Depth (mm) DOM2CU 2 240 189 127 DOM4CU

41

Panelboards - I-Line MCCB panelboards Panelboard accessories

Termination barsSolid brass terminal bars provide tunnel terminals. Main neutral and earth bars are pre-drilled to accept the termination bars indicated. Bars suitable for size 1 and 2.

MCCB locking devicesProvide facilities for padlocking MCCB’s.

Reference number Number of ways Conductor size

NE916 9 25

NE1816 18 25

NE950 9 50

NE7150 7 150

NE13150 13 150

Frame Reference number Facility Padlocks

SFA HPAFK On/Off 1

C 3 pole W29370 Off 3

SLA HPALM Off 1

SLA HPAXLM* Off 1

PJA 44936 Off 1

* Use with handle extension

Page 42: Ready to install€¦ · 8 Domae consumer units - dimensions & technical data Insulated units Reference number No. of ways Height (mm) Width (mm) Depth (mm) DOM2CU 2 240 189 127 DOM4CU

42

Panelboards - I-Line MCCB panelboards MCCB accessories

Cable clamp terminalsTriple pole CDX, CNX and CHX MCCB’s are supplied with bolt connections. Field fitted terminals.

Crimp cable lugsSpecial lugs for fitting oversize cables to CD, CN and CH MCCB’s.

Handle extensionFor use in providing extra leverage when operating larger frame I-Line MCCB’s.

Terminal extension pads3 plated copper pads to which crimp type lugs may be fastened (unshrouded).

Reference number

16- 160A LV429242 set of 3 1.5 - 95mm2

200- 250A LV429259 set of 3 95 - 185mm2

Reference number

LV429252 set of 3 120mm2 Copper

LV429253 set of 3 150mm2 Copper

LV429254 set of 3 185mm2 Copper

LV429504 set of 3 150mm2 Aluminium

LV429506 set of 3 185mm2 Aluminium

Required for oversized cables only.

Terminal shieldsReference number Quantity

CDX, CNX and CHX short (15mm) LV429515 1

CDX, CNX and CHX long (80mm) LV429517X 1

SLA LCA1 2

SMA MCA1 2

SFA single pole FTS 1

Use short terminal shields with tunnel terminals.Use long terminal shields with crimp terminals.

Reference number

SLA frame AHEXLI

SM MAHEX

PJA frame 46996

Reference number

C frame LV431563

SLA frame LATK3

PJA PJATK3

The pads require an air gap of 25mm between them and adjacent MCCB’s the use of an HNM1BL either side of the MCCB will provide the necessary spacing.

Page 43: Ready to install€¦ · 8 Domae consumer units - dimensions & technical data Insulated units Reference number No. of ways Height (mm) Width (mm) Depth (mm) DOM2CU 2 240 189 127 DOM4CU

43

Panelboards - I-Line MCCB panelboards MCCB accessories

Shunt trip (ST)Energisation of shunt trip coil will initiate MCCB tripping.

Under voltage release (UVR)The coil must be energised before the MCCB can be switched on.

Auxiliary switches (aux)Change over contacts indicate MCCB contact position. For CDX, CNX and CHX may be used as an alarm switch.

Lug unitTo sub-feed power from, or into the busbar stack. Current rating of plug-on lug must be equal to or greater than the incoming protective device.

Order referencesDescription CDX-CNX-CHX SLA

Shunt trip 110/130V 50Hz LV429386 –

Shunt trip 200/240V 50Hz LV429387 –

Shunt trip 120/240V 50Hz – LA11021

Shunt trip 277/480V 50Hz – LA11037

Shunt trip 24V dc LV429390 LA11027

Under voltage release 110/130V 50Hz LV429406 LA11121

Under voltage release 200/240V 50Hz LV429407 LA11124

Under voltage release 24V dc LV429410 LA11127

Auxiliary switch 1 change over contact LV429450 LA11212

Auxiliary switch 2 change over contact LV429450 x 2 LA11352

CDX, CNX and CHX Connection terminals accept wires up to 1.5mm2

SL, Supplied with 1mm2 flying leads

Field installable.

CDX, CNX and CHX Connection terminals accept wires up to 1.5mm2

SL, Supplied with 1mm2 flying leads

Field installable.

CDX, CNX and CHX Connection terminals accept wires up to 1.5mm2

SL, Supplied with 1mm2 flying leads

Field installable.

Reference number Rating Modules Terminal capacity mm2

SL100 100A 3 50

SL225 225A 3 185

SL400 400A 4 300

SL800 800A 6 3 x 240

Page 44: Ready to install€¦ · 8 Domae consumer units - dimensions & technical data Insulated units Reference number No. of ways Height (mm) Width (mm) Depth (mm) DOM2CU 2 240 189 127 DOM4CU

44

Panelboards - I-Line MCCB panelboards Metering facilities

Metering facilitiesThe I-Line Panelboard product range has being enhanced to include the facility to meter incoming and outgoing circuits. This enables contractors to easily and simply meet the requirements of Part L2a of the Building Regulations. These metering kits allow great flexibility in the choice of meter and also in the configuration of the boards. The metering arrangement varies depending on the size of board.

For the Size 1 250A board there is an extension box which may be fitted to the top or bottom of a board to meter the incoming supply.

For Size 1 400A, Size 2 and Size 3 boards components are provided to meter some or all outgoing ways and/or the incoming supply.

Currently most boards have incoming metering kits. These new kits may be used as well as or instead of these existing arrangements.

Size 1 250A boardsThis metering kit is for the incoming supply to the board. It comprises an extension box that can be fitted to the top or the bottom of a standard board. This box contains a three-phase block current transformer, fuses for the voltage supply and a PM700P multi-function meter. Because the main incoming cables pass through this enclosure it is not suitable for a retrofit. The kit comes complete: no other parts are required to install this metering kit. Size 1 (250A)Reference number MPME2501 250A top/bottom metering extension box Size 1 (400A), Size 2 and PanelboardsA standard board can be adapted to meter the incoming supply and some or all of the outgoing circuits by the addition of three components.

These components are1 Metering kit. This contains a replacement wireway door with 96 sq cutouts for the number of outgoing ways of the board plus one. This additional cutout is to meter the incoming supply as required. Blanking plates are supplied for unused meter positions. One door kit per board.2 Current transformer kit. One kit for each circuit to be measured. The kit will comprise a three phase CT block, mounting plate and cable loom. The CT blocks fit to the breakers. The CT size and ratio matches the breaker. 3 The multi-function meter for each circuit to be measured. The meter is selected from the Schneider Electric Power Meter range. See below for details.

Size 1 400AReference number No. of Meters

MPMK104 4 way I-Line metering kit 5

MPMK107 7 way I-Line metering kit 8

MPMK112 12 way I-Line metering kit 13

Size 2 630AReference number No. of Meters

MPMK206 6 way I-Line metering kit 7

MPMK210 10 way I-Line metering kit 11

MPMK214 14 way I-Line metering kit 15

MPMK218 18 way I-Line metering kit 19

Page 45: Ready to install€¦ · 8 Domae consumer units - dimensions & technical data Insulated units Reference number No. of ways Height (mm) Width (mm) Depth (mm) DOM2CU 2 240 189 127 DOM4CU

45

Panelboards - I-Line MCCB panelboards Metering facilities

Outgoing Metering CT set for each MCCB to be monitoredReference number CT ratio

MPCT125 C frame breaker 125/5

MPCT150 C frame breaker 150/5

MPCT250 C frame breaker 250/5

MPCT400 L frame breaker 400/5

MPCT600 M & P frame breakers 600/5

Blank metering platesReference number

3908 Cream 96sq blanking plate

SDBL96 Black/Grey 96mm2

PowerLogic metersReference number

PM700 Multi function PowerMeter

PM700P Multi function PowerMeter with pulse outputs

PM710 Multi function PowerMeter with Modbus RS485 output

PM750 Multi function PowerMeter with Modbus RS485 and pulse outputs

Page 46: Ready to install€¦ · 8 Domae consumer units - dimensions & technical data Insulated units Reference number No. of ways Height (mm) Width (mm) Depth (mm) DOM2CU 2 240 189 127 DOM4CU

46

> Switch and fusegearTwinbreak & Quadbreak

46

Page 47: Ready to install€¦ · 8 Domae consumer units - dimensions & technical data Insulated units Reference number No. of ways Height (mm) Width (mm) Depth (mm) DOM2CU 2 240 189 127 DOM4CU

47

Switch and fusegear - Twinbreak

Switch disconnector fuseApplicationHeavy duty fuse products for use in commercial and industrial environments, providing isolation and traditional fuse protection for electrical loads.Featuresn Rated for 240/415V 50/60Hzn Ratings 20A, 32A, 63A, 100A, SP&SwN, TP&Nn Utilisation category AC20A, AC21A, AC22A, AC23B at rated currentn Degree of protection IP41n Handle position provides positive contact indicationn Door handle prevents door being opened when switch is ON or padlockedn Handle padlockable in ON and OFF positionsn Fuse links supplied as standardConstructionn Live terminals fully shroudedn Door interlock has integral defeat mechanism allowing door to be opened without switching OFF. This feature is not operable when the handle is padlockedn Removable gland plates with cable knockoutsn Lift off door provides greater access for installation and cablingn Door opens within the width of the unit allowing units to be mounted adjacentn Neutral has disconnectable link and capacity for 3 outgoing cablesn Keyhole slots in the enclosure base allow easy installationn Earthing kit provided as standardn Easy access to fuse links n Steelwork finished in polyester epoxy powder

SBC106 is supplied complete with 4 x TBCKIT. SBC109 is supplied complete with 6 x TBCKIT.

Technical dataStandard BS EN 60947-3

Rated operational voltage 415V 50/60Hz

Rating 20A 32A 63A 100A

Rated current at 400C, A 20 32 63 100

Rated impulse voltage 6kV 6kV 6kV 6kV

Rated short time withstand Icw, A 416 416 756 1300

Rated short circuit making capacity Icm 1.35kA 1.35kA 1.35kA 3.5kA

Rated short circuit breaking capacity Icn 50kA 50kA 50kA 50kA

Utilisation category at rated current AC-20A/ 21A/ 22A/ 23B

Kilowatt rating 11kW 15kW 30kW 55kW

Cable size, maximum mm2 10mm2 10mm2 25mm2 50mm2

Reference numbersRating Single pole & switched neutral Three pole with neutral link AC21/22/23 Switch Switch Switch Switch disconnector disconnector disconnector disconnector fuse fuse

20A SD202SFK SD202SW SD203SFK SD203SW

32A SD322SFK SD322SW SD323SFK SD323SW

63A SD632SFK SD632SW SD633SFK SD633SW

100A SD1002SFK SD1002SW SD1003SFK SD1003SW

125A – – – SD1253SW

160A – – – SD1603SW

Busbar chambersStep 1Select Twinbreak units required. If a 125 or 160A unit is fitted the rating of the adjacent units cannot exceed 63A.Step 2Select appropriate busbar chamber.

Current rating Number of units Number of unitsAmps 4 6

160 SBC106 SBC109

Page 48: Ready to install€¦ · 8 Domae consumer units - dimensions & technical data Insulated units Reference number No. of ways Height (mm) Width (mm) Depth (mm) DOM2CU 2 240 189 127 DOM4CU

48

Switch and fusegear - Quadbreak

Fuse switch disconnectorApplicationHeavy duty fuse products for use in commercial and industrial environments, providing isolation and traditional fuse protection for electrical loads.

Featuresn Rated for 240/415V 50/60Hzn Ratings 100A, 160A, 200A, 250A, 315A, 400A, 500A, 630A TP&Nn Utilisation category AC20A, AC21A, AC22A, AC23B at rated current, AC23A for ratings up to 160An Handle position provides positive contact indicationn Door handle prevents door being opened when switch is ON or padlockedn Handle padlockable in ON and OFF positionsn Device may be fed to either top or bottom terminalsn Fuse links or copper links supplied as standard

Constructionn All terminals are fully shroudedn Quick make and break silver plated contactsn Door interlock has defeat mechanism allowing switch to be closed with door openn Removable plain gland plates are fitted at top and bottomn Cabling space may be increased by the addition of the cable boxesn Lift off door provides greater access for installation and cablingn Door opens within the width of the unit allowing units to be mounted adjacentn Neutral is fitted with disconnectable links n Earthing kit provided as standardn Easy access to fuse linksn Removable cross rails allow cables to be laid in easilyn Direct front access to terminals without dismantling the mechanismn Clear shrouds allow easy access for inspection and visual indication of contact position n Steelwork finished in polyester epoxy powder

Reference numbersRating Single pole & switched neutral Three pole with neutral link AC21/22/23 Switch Switch Switch Switch Recommended Spare disconnector disconnector disconnector disconnector cable box links fuse fuse

63A SQB0632K SQB0632L SQB0633K SQB0633L

100A SQB1002K SQB1002L SQB1003K SQB1003L SQBX100

XCL160

160A SQB1602K SQB1602L SQB1603K SQB1603L SQBX160

200A SQB2002K SQB2002L SQB2003K – SQBX250

250A SQB2502K SQB2502L SQB2503K SQB2503L XCL250

315A – – SQB3153K – –

400A – – SQB4003K SQB4003L SQBX500 XCL400

500A – – SQB5003K SQB5003L XCL630

630A – – SQB6303K SQB6303L SQBX630

800A – – – SQB8003L XCL800

Castell figure locksQuadbreak can be factory fitted with Castell interlock type FS for locking in off position.To order:1 Specify required unit e.g. SQB2503K2 Add Castle figure lock order suffix EY3 Add Castle key symbol e.g. A

Thus the order reference for a 250A switch disconnector fuse fitted with a Castell lock symbol A is SQB2503KEYA.

Page 49: Ready to install€¦ · 8 Domae consumer units - dimensions & technical data Insulated units Reference number No. of ways Height (mm) Width (mm) Depth (mm) DOM2CU 2 240 189 127 DOM4CU

49

Switch and fusegear - Quadbreak busbar chambers

Busbar chambersPrimarily designed for Quadbreak switch disconnector (fuse) the Quadbreak busbar chamber can be used for the mounting of any equipment.n Manufactured in accordance with BS EN 60439-1n 200, 400, 630 and 800 rated copper busbarsn Available in 750, 1200 and 1800mm lengthsn Rigid constructionn Copper link kits available for direct connection of Quadbreak switch disconnector (fuse)n Overall height and depth of units remains unchanged for the different current ratings

Height = 450mmDepth = 215mm

* The busbar connection kits allow 2 or more busbar chambers to be electrically and mechanically joined together providing facilities for a greater number of outgoing circuits.** The cable connection kits comprise 4 bolts, nuts and washers to connect a set of cables fitted with crimped lugs to the busbars.

Busbar chamber ratings

Busbar connection kitsEach kit comprises connections for three phases and neutral.

Fuse switch connection kitsEach kit comprises connections for three phases and neutral.

Rating (A) Length 750mm Length 1200mm Length 1800mm

Reference number Reference number Reference number

200 SBC20007TN SBC20012TN SBC20018TN

400 SBC40007TN SBC40012TN SBC40018TN

630 SBC63007TN SBC63012TN SBC63018TN

800 SBC80007TN SBC80012TN SBC80018TN

Busbar interconnections Flexible busbar Cable connections to link busbar interconnections to connect Rating (A) chambers* to link non Square D to busbars** busbar chambers Reference number Reference number Reference number

200 CEC200 – FTC200

400 CEC400 CED400 FTC400

600 CEC630 CED630 FTC600

800 CEC800 CED800 FTC800

Rating (A) Top mounted Bottom mounted

Reference number Reference number

63/160A QBL160TN QBL160TN

200/250A QBL250TN QBL250TN

315/630A QBL630TTN QBL630BTN

800A – QBL800BTN

Page 50: Ready to install€¦ · 8 Domae consumer units - dimensions & technical data Insulated units Reference number No. of ways Height (mm) Width (mm) Depth (mm) DOM2CU 2 240 189 127 DOM4CU

50

Switch and fusegear - Quadbreak dimensions

Fuse switch disconnector

Busbar chambers

C6

L

J

3333

33

G

25

H

EARTH BOLT

CASTELL

LOCK

END PLATE

EF F

B

60

60

A

CABLE ENTRY

BOX

D

K

Reference Dimensions (mm) Packed number A B C weight (kg)

SBC106 600 350 120 9.6

SBC109 900 350 120 14.25

Current Reference Switch enclosures (mm) Packed Reference Cable entry box (mm)rating number A B C D E F G H weight (kg) number J K L

63A SQB0632K SQB0633K

380 292 200 260 130 81 142 226 14.5 SQBX100 100 292 200 SQB0632L SQB0633L

100A SQB1002K SQB1003K

380 292 200 260 130 81 142 226 15.6 SQBX100 100 292 200 SQB1002L SQB1003L

160A SQB1602K SQB1603K

380 292 200 260 130 81 142 226 15.6 SQBX160 150 292 200 SQB1602L SQB1603L

SQB2003K 200A/ SQB2502K 250A SQB2503K 380 340 200 260 180 81 142 274 19.5 SQBX250 180 340 200 SQB2502L SQB2503L

315A/ SQB3153K400A SQB4003K SQB4003L 455 489 270 335 289 100 212 423 36.2 SQBX500 300 489 270500A SQB5003K SQB5003L

630A SQB6303K 800A SQB6303L 455 489 270 335 289 100 212 423 36.2 SQBX630 400 489 270 SQB8003L

800A unit is provided with cable extension pads which are external to the above dimensions. Cable entry box SQBX630 must be used except where fitted to a Quadbreak busbar chamber.

Page 51: Ready to install€¦ · 8 Domae consumer units - dimensions & technical data Insulated units Reference number No. of ways Height (mm) Width (mm) Depth (mm) DOM2CU 2 240 189 127 DOM4CU

51

Index

Product Code

Page No.

Product Code

Page No.

Product Code

Page No.

Product Code

Page No.

3908 45

46996 42

400INSKN 38

400kW 38

600INSKN 38

630kW 38

AHEXLI 42

CDXAE34016 30, 33, 36

CDXAE34025 30, 33, 36

CDXAE34032 30, 33, 36

CDXAE34040 30, 33, 36

CDXAE34050 30, 33, 36

CDXAE34063 30, 33, 36

CDXAE34080 30, 33, 36

CDXAE34100 30, 33, 36

CEC200 49

CEC400 49

CEC630 49

CEC800 49

CED400 49

CED630 49

CED800 49

CHAXE34250 32

CHXAE34016 30, 33, 36

CHXAE34025 30, 33, 36

CHXAE34032 30, 33, 36

CHXAE34040 30, 33, 36

CHXAE34050 30, 33, 36

CHXAE34063 30, 33, 36

CHXAE34080 30, 33, 36

CHXAE34100 30, 33, 36

CHXAE34125 30, 33, 36

CHXAE34160 30, 33, 36

CHXAE34200 30, 33, 36

CHXAE34250 29, 30, 33, 36

CNAXE34000S10 29, 32

CNAXE34000S15 29, 32

CNAXE34000S25 29, 32

CNXAE24250E20 30, 33, 36

CNXAE34016 30, 33, 36

CNXAE34025 30, 33, 36

CNXAE34032 30, 33, 36

CNXAE34040 30, 33, 36

CNXAE34050 30, 33, 36

CNXAE34063 30, 33, 36

CNXAE34080 30, 33, 36

CNXAE34100 30, 33, 36

CNXAE34125 30, 33, 36

CNXAE34160 30, 33, 36

CNXAE34160E20 30, 33, 36

CNXAE34200 30, 33, 36

CNXAE34250 29, 33, 36

CPS9 13

DOM03B6 7, 9

DOM06B6 7, 9

DOM06B6R30 7, 9

DOM06C6 7, 9

DOM100R100 6, 9

DOM100R100SP 6, 9

DOM100R30P 6, 9

DOM100SW 6, 9

DOM10B6 7, 9

DOM10B6R30 7, 9

DOM10C6 7, 9

DOM12CU 6, 8

DOM12MCU 6, 8

DOM16B6 7, 9

DOM16B6R30 7, 9

DOM16BKIT 7

DOM16C6 7, 9

DOM16CU 6, 8

DOM16MCU 6, 8

DOM20B6 7, 9

DOM20B6R30 7, 9

DOM20CU 6, 8

DOM2CU 6, 8

DOM2MCU 6, 8

DOM32B6 7, 9

DOM32B6R30 7, 9

DOM40B6 7, 9

DOM40B6R30 7, 9

DOM45B6 7, 9

DOM45B6R30 7, 9

DOM4CU 6, 8

DOM4MCU 6, 8

DOM50B6 7, 9

DOM63R30 6, 9

DOM63R30KIT2 6

DOM63SW 6, 9

DOM6CU 6, 8

DOM6MCU 6, 8

DOM80R30 6, 9

DOM80R30KIT2 6

DOM8CU 6, 8

DOM8MCU 6, 8

DOMEARTHKIT 7

DOMLKIT 7, 13

DOMR4R4CU 6, 8

DOMR4R4MCU 6, 8

DOMR6R6CU 6, 8

DOMR6R6DCU 6, 8

DOMR6R6DMCU 6, 8

DOMR6R6MCU 6, 8

DOMR8R8DCU 6, 8

DOMS2R5R5DCU 6, 8

DOMS2R5R5DMCU 6, 8

DOMS2R7R7DCU 6, 8

EXM522051 31

EXMS1170 34

EXMS1742 34

EXMS20411 31

EXMS53 38

EXMS62 38

EXMS71 38

EXMS80 38

EXMS827 34

EXS151 34

EXS29 38

EXS91 31

FTC200 49

FTC400 49

FTC630 49

FTC800 49

FTS 42

GARAGE63D 6

HNF1BL 34, 38

HNF4BL 34, 38

HNM1BL 31, 43, 40

HNM4BL 31, 43, 40

HPAFK 41

HPALM 34

HPALM 41

HPAXLM 41

KITBOXD 7

KITBOXD80 7

KITBOXDM 7

KITBOXDM1263 7

KITBOXDM1280 7

KQ10C3100 24

KQ10C380 24

KQK33 31, 34, 38, 40

LA11021 43

LA11027 43

LA11037 43

LA11121 43

LA11124 43

LA11127 43

LA11212 43

LA11352 43

LATK3 42

LCA1 42

LV425252 30, 33, 36

LV429242 30, 33, 36

LV429242 42

LV429252 42

LV429253 42

LV429254 42

LV429259 30, 33, 36, 42

LV429386 43

LV429387 43

LV429390 43

LV429406 43

LV429407 43

LV429410 43

LV429450 43

LV429504 42

LV429506 42

LV429515 42

LV429517 42

LV431563 42

MAHEX 42

MCA1 42

ML630 35

MP250121 29

MP25061 29

MP250INS 31

MP250kW 31

MP400121 32

MP40041 32

MP40071 32

MP400INS 34

MP400kW 34

MP630102 35

MP630142 35

MP630182 35

MP63062 35

MPCT125 33, 37, 45

MPCT150 33, 37, 45

MPCT250 33, 37, 45

MPCT400 37

MPCT600 37

MPME2501 30

MPMK104 33, 44

MPMK107 33, 44

MPMK112 33, 44

MPMK206 37, 44

MPMK210 37, 44

MPMK214 37, 44

MPMK218 37, 44

MSIL636 38

NE13150 41

NE1816 41

NE7150 41

NE916 41

NE950 41

PJA36000560 35

PJA36060CU31A 35

PJTK3 42

PM700 33, 37, 45

PM700P 33, 37, 45

PM710 33, 37, 45

PM750 33, 37, 45

QBL160TN 49

QBL160TN 49

QBL250TN 49

QBL250TN 49

QBL630BTN 49

QBL630TTN 49

QBL800BTN 49

QOEPLA 13

QOKS1 31, 34, 40

QOPL 13

RSD4IP54 26

SBC106 47, 50

SBC109 47, 50

SBC20007TN 49

SBC20012TN 49

SBC20018TN 49

SBC40007TN 49

SBC40012TN 49

SBC40018TN 49

SBC63007TN 49

Page 52: Ready to install€¦ · 8 Domae consumer units - dimensions & technical data Insulated units Reference number No. of ways Height (mm) Width (mm) Depth (mm) DOM2CU 2 240 189 127 DOM4CU

52

Index

SE10C332 24

SE10C340 24

SE10C350 24

SE10C363 24

SE10D106 24

SE10D110 24

SE10D116 24

SE10D120 24

SE10D125 24

SE10D132 24

SE10D140 24

SE10D150 24

SE10D163 24

SE10D206 24

SE10D210 24

SE10D216 24

SE10D220 24

SE10D225 24

SE10D232 24

SE10D240 24

SE10D250 24

SE10D263 24

SE10D306 24

SE10D310 24

SE10D316 24

SE10D320 24

SE10D325 24

SE10D332 24

SE10D340 24

SE10D350 24

SE10D363 24

SE1100L 20

SE1100L 23

SE125A12 19

SE125A16 19

SE125A24 19

SE125A4SL6 19

SE125A4SL8 19

SE125A5SL5 19

SE125A6 19

SE125A6SL6 19

SE125A8 19

SE125L2 20

SE125L4 22

SE125SPP 23

SE125SW2 20

SE125SW3L 22

SE125SW4 22

SE12B250 21

SE12B2D 21

SE12B2D 27

SE12BCD 27

SE160MCCB3L 22

SE160RCD 22

SE160SW3L 22

SE160SW4 22

SE172BES 27

SE17BES 21

SE18B250 21

SE18B2D 21, 27

SE18BCD 27

SE200MCCB3L 22

SE200SW3L 22

SE200SW4 22

SE24B250 21

SE250L4P 22

SE250MCCB3L 22

SE250MET 22

SE250SPP 23

SE250SW3L 22

SE250SW4 22

SE36B250 21

SE36B3D 21, 27

SE36BCD 27

SE48B250 21

SE54B250 21

SE54B4D 21, 27

SE54BCD 27

SE63SLK 21, 23

SE72B250 21

SE72BL 23

SEA12S12 19

SEAE16 20

SEB36S24125 22

SEB36S24250 22

SEB42S18125 22

SEB42S18250 22

SEB48S12125 22

SEB48S12250 22

SEBEK1 23

SEBEK2 23

SEBEK3 23

SEBES 23, 27

SEBFCF 23

SEBNC 23

SEBP25 20

SECE12T 23

SECE24T 23

SECSW100 22

SED100032 20, 26

SED100102 20, 26

SED100304 22, 26

SED100304S 22, 26

SED25032 26

SED25034 26

SED25104 26

SED25302 26

SED25304 26

SED40032 26

SED40034 26

SED40102 26

SED40104 26

SED40302 26

SED40304 26

SED63032 20

SED63032 26

SED63034 26

SED63102 20

SED63102 26

SED63104 26

SED63302 20

SED63302 26

SED63304 26

SED80032 26

SED80034 22

SED80034 26

SEE106B03 25

SEE106C01 25

SEE106C03 25

SEE106C10 25

SEE110B03 25

SEE110C01 25

SEE110C03 25

SEE110C10 25

SEE116B03 25

SEE116C01 25

SEE116C03 25

SEE116C10 25

SEE120B03 25

SEE120C01 25

SEE120C03 25

SEE120C10 25

SEE125B03 25

SEE125C01 25

SEE125C03 25

SEE125C10 25

SEE132B03 25

SEE132C01 25

SEE132C03 25

SEE132C10 25

SEE140B03 25

SEE140C01 25

SEE140C03 25

SEE140C10 25

SEE145B03 25

SEE145C01 25

SEE145C03 25

SEE145C10 25

SEEXGP 23

SEGP 23

SEGPKO 23

SEJK 21, 23

SEK 20, 23

SEK33 23

SEPD 23

SEPL 20, 23

SEPLMCB 20, 23

SEPLRCBO 20, 23

SESDC 20, 23

SESJK 23

SFA1016A,B,C 29, 32, 35

SFA1020A,B,C 29, 32, 35

SFA1032A,B,C 29, 32, 35

SFA1040A,B,C 29, 32, 35

SBC63012TN 49

SBC63018TN 49

SBC80007TN 49

SBC80012TN 49

SBC80018TN 49

SD1002SFK 47, 50

SD1002SW 47, 50

SD1003SFK 47, 50

SD1003SW 47, 50

SD1253SW 47, 50

SD1603SW 47, 50

SD202SFK 47, 50

SD202SW 47, 50

SD203SFK 47, 50

SD203SW 47, 50

SD322SFK 47, 50

SD322SW 47, 50

SD323SFK 47, 50

SD323SW 47, 50

SD632SFK 47, 50

SD632SW 47, 50

SD633SFK 47, 50

SD633SW 47, 50

SDBL96 45

SE100MCCB3L 22

SE10B103 24

SE10B106 24

SE10B110 24

SE10B116 24

SE10B120 24

SE10B125 24

SE10B132 24

SE10B140 24

SE10B150 24

SE10B163 24

SE10C106 24

SE10C110 24

SE10C116 24

SE10C120 24

SE10C125 24

SE10C132 24

SE10C140 24

SE10C150 24

SE10C163 24

SE10C206 24

SE10C210 24

SE10C216 24

SE10C220 24

SE10C225 24

SE10C232 24

SE10C240 24

SE10C250 24

SE10C263 24

SE10C306 24

SE10C310 24

SE10C316 24

SE10C320 24

SE10C325 24

Product Code

Page No.

Product Code

Page No.

Product Code

Page No.

Product Code

Page No.

Page 53: Ready to install€¦ · 8 Domae consumer units - dimensions & technical data Insulated units Reference number No. of ways Height (mm) Width (mm) Depth (mm) DOM2CU 2 240 189 127 DOM4CU

53

Index

SFA1050A,B,C 29, 32, 35

SFA1063A,B,C 29, 32, 35

SFA1080A,B,C 29, 32, 35

SFA1100A,B,C 29, 32, 35

SFA2016AB,BC,AC 29, 32, 35

SFA2020AB,BC,AC 29, 32, 35

SFA2032AB,BC,AC 29, 32, 35

SFA2040AB,BC,AC 29, 32, 35

SFA2050AB,BC,AC 29, 32, 35

SFA2063AB,BC,AC 29, 32, 35

SFA2080AB,BC,AC 29, 32, 35

SFA2100AB,BC,AC 29, 32, 35

SHOWER6340D 6

SHOWER6345D 6

SL100 43

SL225 29, 32, 43

SL400 43

SL800 43

SLA3000M 32, 35

SLA3250 35

SLA3400 32, 35

SQB0632K 48, 50

SQB0632L 48, 50

SQB0633K 48, 50

SQB0633L 48, 50

SQB1002K 48, 50

SQB1002L 48, 50

SQB1003K 48, 50

SQB1003L 48, 50

SQB1602K 48, 50

SQB1602L 48, 50

SQB1603K 48, 50

SQB1603L 48, 50

SQB2002K 48, 50

SQB2002L 48, 50

SQB2003K 48, 50

SQB2502K 48, 50

SQB2502L 48, 50

SQB2503K 48, 50

SQB2503L 48, 50

SQB3153K 48, 50

SQB4003K 48, 50

SQB4003L 48, 50

SQB5003K 48, 50

SQB5003L 48, 50

SQB6303K 48, 50

SQB6303L 48, 50

SQB8003L 48, 50

SQBX100 48, 50

SQBX250 48, 50

SQBX500 48, 50

SQBX630 48, 50

SQO103EB6 13, 17

SQO103EC6 13, 17

SQO106EB6 13, 17

SQO106EC6 13, 17

SQO1100L 12, 17

SQO1100M 12, 17

SQO110EB6 13, 17

SQO110EC6 13, 17

SQO116EB6 13, 17

SQO116EC6 13, 17

SQO12 12, 14

SQO120EB6 13, 17

SQO120EC6 13, 17

SQO125EB6 13, 17

SQO125EC6 13, 17

SQO132EB6 13, 17

SQO132EC6 13, 17

SQO140EB6 13, 17

SQO140EC6 13, 17

SQO150EB6 13, 17

SQO150EC6 13, 17

SQO16 12, 14

SQO163EB6 13, 17

SQO163EC6 13, 17

SQO2 12, 14

SQO204 12, 16

SQO23 12, 14

SQO303 12, 16

SQO4 12, 14

SQO402 12, 16

SQO406 12, 16

SQO505 12, 16

SQO6 12, 14

SQO604 12, 16

SQO703 12, 16

SQO707 12, 16

SQO8 12, 14

SQODNBP 13, 20, 23

SQODS2R5R5 12, 15

SQOE063030 12, 17, 20

SQOE063100 12, 17, 20

SQOE100030 12, 17, 20

SQOE100100 12, 17, 20

SQOE100100S 12, 17, 20

SQOE100300 12, 17, 20

SQOM12 12, 14

SQOM16 12, 14

SQOM2 12, 14

SQOM24 12, 14

SQOM4 12, 14

SQOM505 12, 15

SQOM6 12, 14

SQOM604 12, 16

SQOM60501 12, 16

SQOM70401 12, 16

SQOM707 12, 16

SQOM8 12, 14

SQOMDS2R5R5 12, 15

SQOMS2R5R5 12, 15

SQOMS4R6 12, 15

SQOMS5R5 12, 15

SQOMS6R4 12, 15

SQOMS7R7 12, 15

SQOMSR6R6 12, 15

Product Code

Page No.

Product Code

Page No.

Product Code

Page No.

Product Code

Page No.

SQOR106B03 13, 17

SQOR110B03 13, 17

SQOR116B03 13, 17

SQOR120B03 13, 17

SQOR132B03 13, 17

SQOR145B03 13, 17

SQOS2R4 12, 15

SQOS2R5R5 12, 15

SQOS3R3 12, 15

SQOS4R2 12, 15

SQOS4R6 12, 15

SQOS5R5 12, 15

SQOS6R4 12, 15

SQOS7R3 12, 15

SQOS7R7 12, 15

SQOSR6R6 12, 15

TKA12 32, 34

TKA4 32, 34

TKA7 32, 34

W29370 23, 31, 41

WALLET 23

XCL250 48

XCL400 48, 50

XCL630 48

XCL800 48

Page 54: Ready to install€¦ · 8 Domae consumer units - dimensions & technical data Insulated units Reference number No. of ways Height (mm) Width (mm) Depth (mm) DOM2CU 2 240 189 127 DOM4CU

54

Notes

Page 55: Ready to install€¦ · 8 Domae consumer units - dimensions & technical data Insulated units Reference number No. of ways Height (mm) Width (mm) Depth (mm) DOM2CU 2 240 189 127 DOM4CU

55

Notes

Page 56: Ready to install€¦ · 8 Domae consumer units - dimensions & technical data Insulated units Reference number No. of ways Height (mm) Width (mm) Depth (mm) DOM2CU 2 240 189 127 DOM4CU

UK contact details -

0870 608 8 608Fax 0870 608 8 606

Ireland contact details -

01 601 2200Fax 01 601 2201

As a global specialist in energy management with operations in more than 100 countries, Schneider Electric offers integrated solutions across multiple market segments, including leadership positions in Utilities & Infrastructures, Industries & Machine Manufacturers, Non-residential Buildings, Data Centres & Networks and in Residential .

Focused on making energy safe, reliable, efficient, productive and green, the Group’s 130,000 plus employees achieved sales of 22.4 billion euros in 2011, through an active commitment to help individuals and organisations make the most of their energy.

We are changing our brand names and becoming one Schneider Electric. You’ll get the same great quality products, but from one name you can remember and trust. This provides you and your customers with the reassurance associated with Schneider Electric.

Some of our market leading brands have already become Schneider Electric including Merlin Gerin, Telemecanique, Square D, GET, Mita, Sarel, Himel, Thorsman, Tower and TAC.

Working as one Schneider Electric makes it clearer that our ranges are highly compatible for integrated solutions.

Schneider Electric Ltd

Schneider Electric Limited is a company registered in England and Wales.Registered number: 1407228. Registered office: Stafford Park 5, Telford, Shropshire TF3 3BL.

© 2012 Schneider Electric. All Rights Reserved. Schneider Electric, Active Energy Management, Compact, EcoStruxure, ION Enterprise, iRIO, Make the most of your energy, Masterpact, Micrologic, Power Plant To Plug, Modbus, and PowerLogic are owned by Schneider Electric Industries SAS, or its affiliated companies in the United States and other countries.

As standards, specifications and designs change from time to time, please ask for confirmation of the information given in this publication. S

E81

02