Page 1: Real time data awareness and advanced data processing at ...cdn.osisoft.com/corp/ru/presentations/Industry...Title: Real time data awareness and advanced data processing at CECRE (Control

© Copyr i gh t 2014 O SIs o f t , LLC .

Presented by

Real time data awareness

and advanced data

processing at CECRE

(Control Center for

Renewable Energies)

Juan Julián Peiró Peña

Page 2: Real time data awareness and advanced data processing at ...cdn.osisoft.com/corp/ru/presentations/Industry...Title: Real time data awareness and advanced data processing at CECRE (Control

© Copyr i gh t 2014 O SIs o f t , LLC . 2

Page 3: Real time data awareness and advanced data processing at ...cdn.osisoft.com/corp/ru/presentations/Industry...Title: Real time data awareness and advanced data processing at CECRE (Control

© Copyr i gh t 2014 O SIs o f t , LLC .

INDEX

3

1

3

4 Outline & Conclusions

CECRE: Control Center for Renewable Energies

Red Eléctrica de España (REE)

2 CECOEL: Electrical Control Center

Page 4: Real time data awareness and advanced data processing at ...cdn.osisoft.com/corp/ru/presentations/Industry...Title: Real time data awareness and advanced data processing at CECRE (Control

© Copyr i gh t 2014 O SIs o f t , LLC . 4

1 Red Eléctrica de España (REE)

Page 5: Real time data awareness and advanced data processing at ...cdn.osisoft.com/corp/ru/presentations/Industry...Title: Real time data awareness and advanced data processing at CECRE (Control

© Copyr i gh t 2014 O SIs o f t , LLC . 5

System Operation:

Operates the grid and coordinates its uses with the

generation facilities in order to ensure the

security and continuity of the electricity supply.

Transmission (since 2007 as exclusive transmission company):

The development and the maintenance of the transmission facilities

~ 41,000 km of lines and 78,000 MW of transforming capacity

1 Red Eléctrica de España (REE)

Page 6: Real time data awareness and advanced data processing at ...cdn.osisoft.com/corp/ru/presentations/Industry...Title: Real time data awareness and advanced data processing at CECRE (Control

© Copyr i gh t 2014 O SIs o f t , LLC .

GeneratorsInternational Exchanges · REERenewable Energy

Demand bids

Energy flowsCommunication

Transmission network· REE System Operator· REE

Market Operator· OMIE

TSO (foreign)

Qualified consumers

Suppliers Last resort suppliers Demand bids

Demand offers

Distribution companies

6

1 Red Eléctrica de España (REE)

Page 7: Real time data awareness and advanced data processing at ...cdn.osisoft.com/corp/ru/presentations/Industry...Title: Real time data awareness and advanced data processing at CECRE (Control

© Copyr i gh t 2014 O SIs o f t , LLC . 7

2 CECOEL: Electrical Control Center

Page 8: Real time data awareness and advanced data processing at ...cdn.osisoft.com/corp/ru/presentations/Industry...Title: Real time data awareness and advanced data processing at CECRE (Control

© Copyr i gh t 2014 O SIs o f t , LLC . 8

Every telemetry is linked point to point

Observability: 47 000 analog and 223 000 digital telemetries updated in less than 12 s

Controlability: 40 000 remote control signals

23.000 telemetries available for retrieving using PI System

EMS System

More than 2.5 billion data values every day

2 CECOEL: Real Time Data

Page 9: Real time data awareness and advanced data processing at ...cdn.osisoft.com/corp/ru/presentations/Industry...Title: Real time data awareness and advanced data processing at CECRE (Control

© Copyr i gh t 2014 O SIs o f t , LLC .

2 CECOEL: Voltage

9

Page 10: Real time data awareness and advanced data processing at ...cdn.osisoft.com/corp/ru/presentations/Industry...Title: Real time data awareness and advanced data processing at CECRE (Control

© Copyr i gh t 2014 O SIs o f t , LLC . 10

2 CECOEL: Installed Generation Capacity May 2014 - 100 GW

Page 11: Real time data awareness and advanced data processing at ...cdn.osisoft.com/corp/ru/presentations/Industry...Title: Real time data awareness and advanced data processing at CECRE (Control

© Copyr i gh t 2014 O SIs o f t , LLC .

Maximum demand

39 183 MW

Lower wind production on peak

hours

High wind production during

off-peak hours

2 CECOEL: Demand Coverage

11

Minimum demand

23 653 MW

Page 12: Real time data awareness and advanced data processing at ...cdn.osisoft.com/corp/ru/presentations/Industry...Title: Real time data awareness and advanced data processing at CECRE (Control

© Copyr i gh t 2014 O SIs o f t , LLC . 12

3 CECRE: Control Center for Renewable Energies

Page 13: Real time data awareness and advanced data processing at ...cdn.osisoft.com/corp/ru/presentations/Industry...Title: Real time data awareness and advanced data processing at CECRE (Control

© Copyr i gh t 2014 O SIs o f t , LLC . 13

3 CECRE: Control Center for Renewable Energies

Page 14: Real time data awareness and advanced data processing at ...cdn.osisoft.com/corp/ru/presentations/Industry...Title: Real time data awareness and advanced data processing at CECRE (Control

© Copyr i gh t 2014 O SIs o f t , LLC . 14

CSP power plants:

Maximumcoverage 64%

Minimumcoverage <1%

3 CECRE: Variability

Page 15: Real time data awareness and advanced data processing at ...cdn.osisoft.com/corp/ru/presentations/Industry...Title: Real time data awareness and advanced data processing at CECRE (Control

© Copyr i gh t 2014 O SIs o f t , LLC .

12 second cycles

RD

1565/2010 Generation aggregation

1 MW < P <= 10 MWGeneration aggregation

P > 10 MW

Connected to a

RESCC or Distributor

Connected to a

RESCC

12 second cycles

OBSERVABILITY &

CONTROLLABILITY OBSERVABILITY

3 CECRE: Regulation

15

Page 16: Real time data awareness and advanced data processing at ...cdn.osisoft.com/corp/ru/presentations/Industry...Title: Real time data awareness and advanced data processing at CECRE (Control

© Copyr i gh t 2014 O SIs o f t , LLC . 16

CCRENOV

System Operator

CECOEL CECORE

CCCONV

CECRE CECRE

3 000 generation installations

37 generation control centers

350 distribution operators

Communication is needed in case of

emergency, outages or maintenance

Distributor

3 CECRE: Control Center for Renewable Energies

Page 17: Real time data awareness and advanced data processing at ...cdn.osisoft.com/corp/ru/presentations/Industry...Title: Real time data awareness and advanced data processing at CECRE (Control

© Copyr i gh t 2014 O SIs o f t , LLC . 17

Real Time Photovoltaic Generation

3 CECRE: Observability

Page 18: Real time data awareness and advanced data processing at ...cdn.osisoft.com/corp/ru/presentations/Industry...Title: Real time data awareness and advanced data processing at CECRE (Control

© Copyr i gh t 2014 O SIs o f t , LLC .18

CECRE

GEMAS

Set points

Real time measurements

CCRE i

20 minutes calculation frequency

SECURITY ANALYSIS USING A REAL TIME WIND SCENARIO

3 CECRE: Controllability

Page 19: Real time data awareness and advanced data processing at ...cdn.osisoft.com/corp/ru/presentations/Industry...Title: Real time data awareness and advanced data processing at CECRE (Control

© Copyr i gh t 2014 O SIs o f t , LLC .

3 CECRE: Controllability

19

Page 20: Real time data awareness and advanced data processing at ...cdn.osisoft.com/corp/ru/presentations/Industry...Title: Real time data awareness and advanced data processing at CECRE (Control

© Copyr i gh t 2014 O SIs o f t , LLC . 20

4 Outline & Conclusions

Page 21: Real time data awareness and advanced data processing at ...cdn.osisoft.com/corp/ru/presentations/Industry...Title: Real time data awareness and advanced data processing at CECRE (Control

© Copyr i gh t 2014 O SIs o f t , LLC . 21

Real time data awareness: 2.5 billion telemetries every day.

PI System is a powerful tool for:

Retrieving both real time and historical data values.

Monitoring at the electrical control center.

Advanced data processing: PI System supports standard programming languages.

4 Outline & Conclusions

Page 22: Real time data awareness and advanced data processing at ...cdn.osisoft.com/corp/ru/presentations/Industry...Title: Real time data awareness and advanced data processing at CECRE (Control

© Copyr i gh t 2014 O SIs o f t , LLC .

Juan Peiró

[email protected]

Electrical Control Center of Red Eléctrica de España

22

Page 23: Real time data awareness and advanced data processing at ...cdn.osisoft.com/corp/ru/presentations/Industry...Title: Real time data awareness and advanced data processing at CECRE (Control

© Copyr i gh t 2014 O SIs o f t , LLC .

Brought to you by