Real Time Water Monitoring and the Shift to a Digital Water Archive

Pinawa, Marina

Page 2: Real Time Water Monitoring and the Shift to a Digital ... · Conductivity, level and ... In-Situ Troll Link ... confusion since it is not classical calibration. Local “Calibration

Why Real Time WQ Monitoring

Traditional versus Spectroscopic Methods

Overview of s::can technology

Fingerprint and the Digital Water Archive

Outline

Page 3: Real Time Water Monitoring and the Shift to a Digital ... · Conductivity, level and ... In-Situ Troll Link ... confusion since it is not classical calibration. Local “Calibration

Why Real Time WQ Monitoring?

Page 4: Real Time Water Monitoring and the Shift to a Digital ... · Conductivity, level and ... In-Situ Troll Link ... confusion since it is not classical calibration. Local “Calibration

Watershed changes

Parameter Exceedance

Event Detection

Trigger Autosampler

Why Real Time WQ Monitoring?

Page 5: Real Time Water Monitoring and the Shift to a Digital ... · Conductivity, level and ... In-Situ Troll Link ... confusion since it is not classical calibration. Local “Calibration

Toxicity Upset detection

Parameter exceedance

Determination of loading values

Why Real Time WQ Monitoring?

Page 6: Real Time Water Monitoring and the Shift to a Digital ... · Conductivity, level and ... In-Situ Troll Link ... confusion since it is not classical calibration. Local “Calibration
Page 7: Real Time Water Monitoring and the Shift to a Digital ... · Conductivity, level and ... In-Situ Troll Link ... confusion since it is not classical calibration. Local “Calibration

A Few Examples of In-Situ Inc. Monitoring Equipment

Aquatroll

100 and 200

Conductivity, level and Temperature

6 cell conductivity sensor

Titanium housing

2 million datapoint

internal datalogger

Communicates via multiple methods including SDI 12

Page 8: Real Time Water Monitoring and the Shift to a Digital ... · Conductivity, level and ... In-Situ Troll Link ... confusion since it is not classical calibration. Local “Calibration

A Few Examples of In-Situ Inc Monitoring Equipment

Page 9: Real Time Water Monitoring and the Shift to a Digital ... · Conductivity, level and ... In-Situ Troll Link ... confusion since it is not classical calibration. Local “Calibration

In-Situ Troll Link Telemetry System

TROLL Link 100 –

GSM/GPRS modem

TROLL Link 102 – CDMA modem

••

TROLL Link 101 – GSM/GPRS modem w/ Data Center link

••

TROLL Link 201 – Iridium

satellite modem with Data Center link

Page 10: Real Time Water Monitoring and the Shift to a Digital ... · Conductivity, level and ... In-Situ Troll Link ... confusion since it is not classical calibration. Local “Calibration

Better Total Accuracy of Measurement

Submersible by-pass; direct install in fluid

Field compatible, (Immediately with regular operator, and with some development by layperson)

Self cleaning (compressed air, or direct brush method) ‏

indirect method, must be parameterized / “Calibration”

The Innovation: The Submersible mobile field probe

Page 11: Real Time Water Monitoring and the Shift to a Digital ... · Conductivity, level and ... In-Situ Troll Link ... confusion since it is not classical calibration. Local “Calibration

The s::can Spectrometer ProbeDesign & Function

Page 12: Real Time Water Monitoring and the Shift to a Digital ... · Conductivity, level and ... In-Situ Troll Link ... confusion since it is not classical calibration. Local “Calibration

The s::can Spectrometer ProbeThe Measuring Principle – Lambert Beer

Optical Pathlength OPL

Concen-tration

C

Radiation IoEmitted by Light Source

Radiation IPassing the Sample

Page 13: Real Time Water Monitoring and the Shift to a Digital ... · Conductivity, level and ... In-Situ Troll Link ... confusion since it is not classical calibration. Local “Calibration

Absorbance Spectra caused by two Substances A & B

A

B

A + B

wavelength

wavelength

wavelength

Water monitoring has to deal with a matrix of numerous dissolved and suspended compounds

Page 14: Real Time Water Monitoring and the Shift to a Digital ... · Conductivity, level and ... In-Situ Troll Link ... confusion since it is not classical calibration. Local “Calibration

0

50

100

150

200

250

300

350

400

450

500

200 250 300 350 400 450 500 550 600 650 700 7500

20

40

60

80

100

120

trübungskompensiertes Spektrum (rechte Achse)

unkompensiertes Spektrum(linke Achse)

Farbe

s::can Messtechnik GmbH

CSB-gesamt, TOC

CSB-gelöst, DOC

[Nanometer]

NO3,NO2

Trübung, Feststoffkonzentration, AFS

UV Strahlung sichtbare Strahlung (Vis)Visible radiation (Vis) UV radiation‏

COD_totalBODTOC

COD_dissolvedDOC

BenzeneTolueneXylenePhenol ...

NO2NO3

Turbidity, TSS (total suspended solids), etc.

colourTurbidity-compensated spectrum; represents the dissolved components only

Non-compensated spectrum; represents the dissolved and non-dissolved substances

Full Spectrum Measurement Principle

Absorption fingerprint across multiple wavelengths of light, created using the s::can

spectro::lyser

Page 15: Real Time Water Monitoring and the Shift to a Digital ... · Conductivity, level and ... In-Situ Troll Link ... confusion since it is not classical calibration. Local “Calibration

UV::lyser

TSS, UV 254, UV254T

Nitro::lyser

NO3 and Turbidity

Carbo::lyser

-

TOC or DOC and Turbidity

Multi::lyser

-

TSS, TOC, DOC, UV 254

s::can G::Series Spectrometers

Parameter Specific Spectrometers

Page 16: Real Time Water Monitoring and the Shift to a Digital ... · Conductivity, level and ... In-Situ Troll Link ... confusion since it is not classical calibration. Local “Calibration

Method: UV-Vis spectrometry; use of the complete absorbance spectrum

Multiple measurements NO3 + TOC + DOC + Turbidity and more

Factory-calibrated

100% drift-compensated (*full* 2-beam-design)

Thus extremely long term stable

No replacement parts

Self cleaning, integrated into compressed air system

Intelligent, many self-diagnosis options

UV-spectrum can be used to alarm on suspect composition of the water (today’s standard for contamination alarm systems in USA)‏

The s::can Spectrometer Probespectro::lyser

Page 17: Real Time Water Monitoring and the Shift to a Digital ... · Conductivity, level and ... In-Situ Troll Link ... confusion since it is not classical calibration. Local “Calibration

“Calibration”

should read Parameterization:•

Not done in classical sense to tune in instrument. Rather•

Thousands of spectra from similar sources analysed and typical parameters built into “Global KALIB”

file. Can be the source of some confusion since it is not classical calibration.

Local “Calibration”•

If results don’t match lab’s results accurately enough, “Local Calibration”

is necessary

Samples are taken and correlated with Spectra, and Lab results are fed back to instrument

Calibration automatic standard or manual ‏

Kalib

is only as good as reference measurement protocols

Multi-point-calibrations possible (spectro::lyser

model only)

s::can Calibration Method

Page 18: Real Time Water Monitoring and the Shift to a Digital ... · Conductivity, level and ... In-Situ Troll Link ... confusion since it is not classical calibration. Local “Calibration

Advanced “Calibration”

for “difficult”

or unique water matrix•

Fast changing / Variable composition of water•

for non-standardized applications and/or new parameters (in case no suitable “Global Calibration”

is available) ‏•

individual service by s::can

partner to develop new spectral algorithm for individual water qualities or individual Parameters

s::can

software tools or traditional Chemometric

tools (PCA & PLS) as well as ana::larm

and contami::spec

can be used

opens unlimited applications in UV/VIS spectrometry

s::can

Calibration

Page 19: Real Time Water Monitoring and the Shift to a Digital ... · Conductivity, level and ... In-Situ Troll Link ... confusion since it is not classical calibration. Local “Calibration

spectro::lyser

Global Calibrations

Set of standardized spectral algorithms allow for multiple parameters a once

Page 20: Real Time Water Monitoring and the Shift to a Digital ... · Conductivity, level and ... In-Situ Troll Link ... confusion since it is not classical calibration. Local “Calibration

Spectral algorithmns better than single wavelength

Application "RIVER" - NO3-N [mg/l]

R2 = 0,93

0

2

4

6

8

10

0 2 4 6 8 10

s::can NO3-Neq [mg/l]

Labo

rato

ry N

O3-

N [m

g/l]

Application "RIVER" - NO3-N [mg/l]

R2 = 0,28

0

2

4

6

8

10

0 20 40 60 80 100

UV230nm [Abs/m]La

bora

tory

NO

3-N

[mg/

l]

Page 21: Real Time Water Monitoring and the Shift to a Digital ... · Conductivity, level and ... In-Situ Troll Link ... confusion since it is not classical calibration. Local “Calibration

ana::pro Software – Difference Spectra

Page 22: Real Time Water Monitoring and the Shift to a Digital ... · Conductivity, level and ... In-Situ Troll Link ... confusion since it is not classical calibration. Local “Calibration

s::can Fingerprint

Wavelength (nm)

Abso

rptio

n [A

bs/m

]

Wavelength (nm)

East Bank

West Bank

Open waterD

iffer

ence

[Abs

/m]

Absorption fingerprints comparing three different water sources.

Page 23: Real Time Water Monitoring and the Shift to a Digital ... · Conductivity, level and ... In-Situ Troll Link ... confusion since it is not classical calibration. Local “Calibration

80208018_35_0x01

00_spectro::lyser_RI

VER000V120 results of s::canpoint: LEARYS                              

Date/Time Status

Turbid. 

[FTUeq]200

.00‐0.00_2

[Turbid._0.

0_1.0_0.0_

0.0]

NO3‐Neq 

[mg/l]10.00

‐0.00_2

[NO3‐

Neq_0.0_1.

0_0.0_0.0]

TOCeq

[mg/l]25.00

‐0.00_2

[TOCeq_0.0

_1.0_0.0_0

.0]

DOCeq

[mg/l]12.00

‐0.00_2

[DOCeq_0.

0_1.0_0.0_

0.0]2009.07.15  

13:08:01 Ok 8.742 0 0.029 0 3.74 0 1.619 02009.07.15  

13:10:01 Ok 9.177 0 0.056 0 3.824 0 1.447 02009.07.15  

13:12:01 Ok 8.565 0 0.056 0 3.779 0 1.56 0

Parameter File Example

Page 24: Real Time Water Monitoring and the Shift to a Digital ... · Conductivity, level and ... In-Situ Troll Link ... confusion since it is not classical calibration. Local “Calibration

80208018_35_0x0100_spe

ctro::lyser_RIVER000V120 results of s::canpoint: LEARYS                              

Date/Time Status_0 200 202.5 205 207.5 210 212.5

2009.07.15  13:08:01 Ok 46.4089 43.5807 40.737 37.2501 33.5732 29.7008

2009.07.15  13:10:01 Ok 47.0013 44.2568 41.4239 37.938 34.1645 30.1617

2009.07.15  13:12:01 Ok 47.7868 44.9812 42.115 38.6449 34.865 30.7539

Fingerprint File

…………

Page 25: Real Time Water Monitoring and the Shift to a Digital ... · Conductivity, level and ... In-Situ Troll Link ... confusion since it is not classical calibration. Local “Calibration

ana::alarm

Strength independent discrimination of contamination

Page 26: Real Time Water Monitoring and the Shift to a Digital ... · Conductivity, level and ... In-Situ Troll Link ... confusion since it is not classical calibration. Local “Calibration

0

2

4

6

8

10

12

14

16

18

20

200 300 400 500 600 700

Wavelength [nm]

Extin

ctio

n [A

bs/m

]

Detection limits in drinking water (KIWA & RIVM test reports)

compound detection limitIsoproturonAldicarb

0,05 mg/L0,1 mg/L

Oxamyl 0,1 mg/LAflatoxineLSDMethamidophos

0,2 mg/L0,5 mg/L1 mg/L

Azinphos –

methyl 2 mg/Lnerve gas simulants 0,1 –

50 mg/L

Page 27: Real Time Water Monitoring and the Shift to a Digital ... · Conductivity, level and ... In-Situ Troll Link ... confusion since it is not classical calibration. Local “Calibration

Shift to a Digital Water Archive

We use security fingerprint and facial recognition

Can we not fingerprint our waters???

Page 28: Real Time Water Monitoring and the Shift to a Digital ... · Conductivity, level and ... In-Situ Troll Link ... confusion since it is not classical calibration. Local “Calibration

Parameter Exceedence

Event Detection

Trigger Autosampler

Shift to a Digital Water Archive

DWA

Use normalized fingerprint for alarms due to unusual changes in a specific watershed environment

Improved modeling of the watershed

Page 29: Real Time Water Monitoring and the Shift to a Digital ... · Conductivity, level and ... In-Situ Troll Link ... confusion since it is not classical calibration. Local “Calibration

Toxicity detection

Parameter exceedence

Shift to a Digital Water Archive

DWA

Post contaminant analysis using fingerprint database

Develop new parameter identification/calibrations/surrogates

Page 30: Real Time Water Monitoring and the Shift to a Digital ... · Conductivity, level and ... In-Situ Troll Link ... confusion since it is not classical calibration. Local “Calibration

Shift to a Digital Water Archive

Fingerprintadditiontoamonitoringdatabaseallowsfor….•Postreviewforspecificorganiccontaminants•Changesintheoverallorganicload•Spectralalarmsbasednormalizedfingerprint

Page 31: Real Time Water Monitoring and the Shift to a Digital ... · Conductivity, level and ... In-Situ Troll Link ... confusion since it is not classical calibration. Local “Calibration

ISO class 2 air

Onboard G Series Static IP Address

Standardized Quick Connects Fluid and Power And Air

Simplified Field Deployment

Page 32: Real Time Water Monitoring and the Shift to a Digital ... · Conductivity, level and ... In-Situ Troll Link ... confusion since it is not classical calibration. Local “Calibration

Lake Winnipeg Water Quality Snapshot

Grand Beach

Page 33: Real Time Water Monitoring and the Shift to a Digital ... · Conductivity, level and ... In-Situ Troll Link ... confusion since it is not classical calibration. Local “Calibration

Questions?

Jeff SimpsonAquatic Life Ltd34 Alexander AvenuePinawa, MB R0E 1L0