recent advances in pem water electrolsyis - sintef international workshop on endurance and...
TRANSCRIPT
![Page 1: Recent Advances in PEM Water Electrolsyis - SINTEF International Workshop on Endurance and Degradation Issues in PEM ... Our MW scale PEMWE is entering a phase where ... Current Modulation](https://reader031.vdocuments.net/reader031/viewer/2022021507/5b0766dc7f8b9ad5548e4ce8/html5/thumbnails/1.jpg)
First International Workshop on Endurance and Degradation Issues in PEM Electrolysis
Joseph Cargnelli, Bernd Evers [email protected] [email protected] March 12th, 2013 | Freiburg, Germany
Recent Advances in PEM Water Electrolsyis
![Page 2: Recent Advances in PEM Water Electrolsyis - SINTEF International Workshop on Endurance and Degradation Issues in PEM ... Our MW scale PEMWE is entering a phase where ... Current Modulation](https://reader031.vdocuments.net/reader031/viewer/2022021507/5b0766dc7f8b9ad5548e4ce8/html5/thumbnails/2.jpg)
We have a wealth of experience and expertise that makes us a
worldwide leader in Alkaline and PEM water electrolysis
Hydrogenics and its partners are committed to the development and
commercialization of Power-to-Gas
Our MW scale PEMWE is entering a phase where engineering and
manufacturing will become as important as technical leadership
Strategic Electrolysis Focus
2
![Page 3: Recent Advances in PEM Water Electrolsyis - SINTEF International Workshop on Endurance and Degradation Issues in PEM ... Our MW scale PEMWE is entering a phase where ... Current Modulation](https://reader031.vdocuments.net/reader031/viewer/2022021507/5b0766dc7f8b9ad5548e4ce8/html5/thumbnails/3.jpg)
HySTAT™ Onsite Hydrogen Generation “Workhorse”
Products designed to meet the challenges of industrial
on-site hydrogen gas users.
3
HySTAT™-60 (Outdoor)
HySTAT™-30 (Indoor)
HySTAT™-15 (Indoor)
Compliant to all major international standards (CE, GOST, US NRTL)
![Page 4: Recent Advances in PEM Water Electrolsyis - SINTEF International Workshop on Endurance and Degradation Issues in PEM ... Our MW scale PEMWE is entering a phase where ... Current Modulation](https://reader031.vdocuments.net/reader031/viewer/2022021507/5b0766dc7f8b9ad5548e4ce8/html5/thumbnails/4.jpg)
Market Segmentation Drives Product Strategy
South Africa: Chemicals Russia: Float Glass
Argentina: Renewable China: Merchant Gas
Greece: Solar Industry
Ukraine: Metallurgy
4
![Page 5: Recent Advances in PEM Water Electrolsyis - SINTEF International Workshop on Endurance and Degradation Issues in PEM ... Our MW scale PEMWE is entering a phase where ... Current Modulation](https://reader031.vdocuments.net/reader031/viewer/2022021507/5b0766dc7f8b9ad5548e4ce8/html5/thumbnails/5.jpg)
Our Power-to-Gas Product Roadmap
Today Needs… Tomorrow
2 MW Installation 5 to 100 MW Solutions 5 MW Building Block
Among the most proven
and utilized technology Products optimized for grid
energy storage scale and cost
Advanced MW-scale
PEMWE plant solutions
5
![Page 6: Recent Advances in PEM Water Electrolsyis - SINTEF International Workshop on Endurance and Degradation Issues in PEM ... Our MW scale PEMWE is entering a phase where ... Current Modulation](https://reader031.vdocuments.net/reader031/viewer/2022021507/5b0766dc7f8b9ad5548e4ce8/html5/thumbnails/6.jpg)
Hydrogenics’ HySTATTM Provides Frequency
Regulation on Ontario Grid
HySTATTM electrolyzer provided frequency regulation by responding
to real-time frequency regulation signals from the IESO on a second-
by-second basis.
6
![Page 7: Recent Advances in PEM Water Electrolsyis - SINTEF International Workshop on Endurance and Degradation Issues in PEM ... Our MW scale PEMWE is entering a phase where ... Current Modulation](https://reader031.vdocuments.net/reader031/viewer/2022021507/5b0766dc7f8b9ad5548e4ce8/html5/thumbnails/7.jpg)
Power-to-Gas Needs - Basis for Innovation
7
![Page 8: Recent Advances in PEM Water Electrolsyis - SINTEF International Workshop on Endurance and Degradation Issues in PEM ... Our MW scale PEMWE is entering a phase where ... Current Modulation](https://reader031.vdocuments.net/reader031/viewer/2022021507/5b0766dc7f8b9ad5548e4ce8/html5/thumbnails/8.jpg)
Power-to-Gas
Plant Targets
8
MW PEMWE Must Address Job-To-Be-Done
![Page 9: Recent Advances in PEM Water Electrolsyis - SINTEF International Workshop on Endurance and Degradation Issues in PEM ... Our MW scale PEMWE is entering a phase where ... Current Modulation](https://reader031.vdocuments.net/reader031/viewer/2022021507/5b0766dc7f8b9ad5548e4ce8/html5/thumbnails/9.jpg)
MW Scale
Electrolyzer
Technology
Stack Efficiency
Improvements
Fast Response and
Dynamic Operation
Reduction of
System Capital Costs
2 1
3 4
Our PEM Electrolysis Technology Focus
9
![Page 10: Recent Advances in PEM Water Electrolsyis - SINTEF International Workshop on Endurance and Degradation Issues in PEM ... Our MW scale PEMWE is entering a phase where ... Current Modulation](https://reader031.vdocuments.net/reader031/viewer/2022021507/5b0766dc7f8b9ad5548e4ce8/html5/thumbnails/10.jpg)
MW PEMWE Technology Development
Stack Design Factors • Electrochemistry
• Heat Transfer
• Fluid Dynamics
• Component Manufacturability/Supply Base
• Material Selection
• Cost
Operating Conditions
• Temperature
• Pressure
• Current Density
10
![Page 11: Recent Advances in PEM Water Electrolsyis - SINTEF International Workshop on Endurance and Degradation Issues in PEM ... Our MW scale PEMWE is entering a phase where ... Current Modulation](https://reader031.vdocuments.net/reader031/viewer/2022021507/5b0766dc7f8b9ad5548e4ce8/html5/thumbnails/11.jpg)
MW-Scale PEMWE Will Have a Broad Impact
Surface Area Efficiency
B.O.P. Cost Power Density
11
![Page 12: Recent Advances in PEM Water Electrolsyis - SINTEF International Workshop on Endurance and Degradation Issues in PEM ... Our MW scale PEMWE is entering a phase where ... Current Modulation](https://reader031.vdocuments.net/reader031/viewer/2022021507/5b0766dc7f8b9ad5548e4ce8/html5/thumbnails/12.jpg)
Technology Area Critical Focus Areas Importance Understanding Opportunity Classification
Membrane
Reduce membrane thickness 9 High High High Priority Research
Membrane mechanical reinforcement 5 Medium Medium High Priority Research
Membrane edge protection 7 High Medium Engineering
Improve membrane dimensional stability 9 High High High Priority Research
Lower cost membrane material 5 Medium Medium Medium Priority Research
Catalyst
Catalyst loading reduction (O2) 7 Medium High High Priority Research
Catalyst loading reduction (H2) 3 Medium Medium Medium Priority Research
Non-precious metal catalyst 3 Low Low Mature Technology
GDL
Optimize GDL thickness & porosity 3 High Low Mature Technology
Improved GDL support to membrane 9 High Low Mature Technology
GDL thickness tolerance 3 Medium Low Mature Technology
Carbon GDL mechanical strength 3 Medium Medium Engineering
Bipolar Plate Plate material compatibility 5 High Low Mature Technology
Low cost large active area plate 5 High Medium Engineering
Protection Coating Alternate lower cost coating materials 7 Medium High High Priority Research
Existing coating cost reduction 7 High Medium Engineering
Cell Design High precision seal design/manufacturing 9 High High Engineering
Reduce pressure drop 3 High Low Low Priority Research
Testing Area
Accelerated Life Testing Reduce design and material validation test time 9 Low High High Priority
Remover barriers for new materials market acceptance 9 Medium High High Priority
MW PEMWE Technology Challenges
![Page 13: Recent Advances in PEM Water Electrolsyis - SINTEF International Workshop on Endurance and Degradation Issues in PEM ... Our MW scale PEMWE is entering a phase where ... Current Modulation](https://reader031.vdocuments.net/reader031/viewer/2022021507/5b0766dc7f8b9ad5548e4ce8/html5/thumbnails/13.jpg)
13
Challenges Facing PEM Electrolysis vs PEM FC
Failure Mode Details PEM Fuel Cells PEM Water Electrolysis
Mech
an
ical
Cause Membrane shrinking/ expansion with
fluctuations in temp & RH
Stack compression variation
Membrane expansion after build
Differential pressure and pressure cycling
Membrane thinning approaching EOL
Mitigation Membrane mechanical reinforcement Membrane mechanical reinforcement
Thicker membrane
Research opportunity Low Medium on thicker membrane (>130μm)
High research opportunity for thin membranes
(<50 μm) used in energy storage applications
Ch
em
ical Cause Polymer function group attacked by
radicals or other active species
Polymer function group attacked by radicals or
other active species
Mitigation Chemically stabilized membrane Chemically stabilized membrane
Research opportunity Low Low
Th
erm
al
Cause Polymer break down due to overheating Polymer break down due to overheating at high
current density
Mitigation Chemically stabilized Stack component selection
BOP design to prevent catastrophic failure
Research opportunity Low
High at overload operation
![Page 14: Recent Advances in PEM Water Electrolsyis - SINTEF International Workshop on Endurance and Degradation Issues in PEM ... Our MW scale PEMWE is entering a phase where ... Current Modulation](https://reader031.vdocuments.net/reader031/viewer/2022021507/5b0766dc7f8b9ad5548e4ce8/html5/thumbnails/14.jpg)
1.0
1.5
2.0
2.5
3.0
0 5,000 10,000 15,000 20,000 25,000 30,000
Me
an
Ce
ll V
olt
ag
e [V
]
Cumulative Time [Hrs]
Continuous 2 A/cm2
2008 Material/Design Technology
(on-going test)
2005 Design/Material Technology
Durability: Significant Progress Made
Failure
14
![Page 15: Recent Advances in PEM Water Electrolsyis - SINTEF International Workshop on Endurance and Degradation Issues in PEM ... Our MW scale PEMWE is entering a phase where ... Current Modulation](https://reader031.vdocuments.net/reader031/viewer/2022021507/5b0766dc7f8b9ad5548e4ce8/html5/thumbnails/15.jpg)
1.96
1.98
2.00
2.02
2.04
2.06
2.08
2.10
0 100 200 300 400 500 600 700 800 900
MC
V [
V]
Cumulative Time [Hrs]
Data filtered at 2A/cm2, 7 barg
Durability: Full Load On/Off Cycling 5,400 on/off cycles demonstrated
(5 min. ON / 5 min. OFF)
15
![Page 16: Recent Advances in PEM Water Electrolsyis - SINTEF International Workshop on Endurance and Degradation Issues in PEM ... Our MW scale PEMWE is entering a phase where ... Current Modulation](https://reader031.vdocuments.net/reader031/viewer/2022021507/5b0766dc7f8b9ad5548e4ce8/html5/thumbnails/16.jpg)
Ongoing test
Durability: High Current Density, 4 A/cm2, 70°C
(4 A/cm2 constant operation)
16
![Page 17: Recent Advances in PEM Water Electrolsyis - SINTEF International Workshop on Endurance and Degradation Issues in PEM ... Our MW scale PEMWE is entering a phase where ... Current Modulation](https://reader031.vdocuments.net/reader031/viewer/2022021507/5b0766dc7f8b9ad5548e4ce8/html5/thumbnails/17.jpg)
Durability: Dynamic Cycle Testing
![Page 18: Recent Advances in PEM Water Electrolsyis - SINTEF International Workshop on Endurance and Degradation Issues in PEM ... Our MW scale PEMWE is entering a phase where ... Current Modulation](https://reader031.vdocuments.net/reader031/viewer/2022021507/5b0766dc7f8b9ad5548e4ce8/html5/thumbnails/18.jpg)
No Degradation after 400 PV Duty Cycles
Operating Current
Density: 2 A/cm2
1.0
1.2
1.4
1.6
1.8
2.0
2.2
2.4
2.6
2.8
3.0
0 2,500 5,000 7,500 10,000
Mean
Cell
Vo
ltag
e [V
]
Cumulative Time [Hrs]
Data filtered at 2 A/cm2, 7 barg
18
![Page 19: Recent Advances in PEM Water Electrolsyis - SINTEF International Workshop on Endurance and Degradation Issues in PEM ... Our MW scale PEMWE is entering a phase where ... Current Modulation](https://reader031.vdocuments.net/reader031/viewer/2022021507/5b0766dc7f8b9ad5548e4ce8/html5/thumbnails/19.jpg)
Hydrogenics Accelerated Testing Experience
Test protocol Expected acceleration mechanism
Elevated temperature
(up to 90 °C)
Chemical degradation due to temperature dependencies of
degradation mechanism reactions
Thermally accelerated membrane breakdown
Mechanical failure caused by fatigue of other stack
components at elevated temperature
Rapid On/Off cycling Chemical and mechanical degradation due to temperature
and pressure cycling
Chemical degradation caused by uncontrolled stack polarity
High current density
(up to 5 A/cm2)
Chemical degradation due to high overpotential
Mechanical degradation from high rate of gas evolution
Intermittent On/Off
Cycling
Chemical and mechanical failures caused by temperature and
pressure fluctuations
19
![Page 20: Recent Advances in PEM Water Electrolsyis - SINTEF International Workshop on Endurance and Degradation Issues in PEM ... Our MW scale PEMWE is entering a phase where ... Current Modulation](https://reader031.vdocuments.net/reader031/viewer/2022021507/5b0766dc7f8b9ad5548e4ce8/html5/thumbnails/20.jpg)
MW Scale PEMWE Short Stack
On/Off Cycling
20
![Page 21: Recent Advances in PEM Water Electrolsyis - SINTEF International Workshop on Endurance and Degradation Issues in PEM ... Our MW scale PEMWE is entering a phase where ... Current Modulation](https://reader031.vdocuments.net/reader031/viewer/2022021507/5b0766dc7f8b9ad5548e4ce8/html5/thumbnails/21.jpg)
MW Scale PEMWE Short Stack
Current Modulation (Isolated Cycle)
21
![Page 22: Recent Advances in PEM Water Electrolsyis - SINTEF International Workshop on Endurance and Degradation Issues in PEM ... Our MW scale PEMWE is entering a phase where ... Current Modulation](https://reader031.vdocuments.net/reader031/viewer/2022021507/5b0766dc7f8b9ad5548e4ce8/html5/thumbnails/22.jpg)
MW Scale PEMWE Short Stack
Current Modulation
22
![Page 23: Recent Advances in PEM Water Electrolsyis - SINTEF International Workshop on Endurance and Degradation Issues in PEM ... Our MW scale PEMWE is entering a phase where ... Current Modulation](https://reader031.vdocuments.net/reader031/viewer/2022021507/5b0766dc7f8b9ad5548e4ce8/html5/thumbnails/23.jpg)
Challenges of PEM Water Electrolysis
Conventional stack materials and designs are too
expensive for widespread acceptance
Lower catalyst loading initiative (especially on the anode)
required, similar to progress made in PEM fuel cell
technology
High efficiency membranes without compromise on
lifetime required for Power-to-Gas market
Design and material validation testing is too long.
A reliable accelerated life testing protocol is required
23
![Page 24: Recent Advances in PEM Water Electrolsyis - SINTEF International Workshop on Endurance and Degradation Issues in PEM ... Our MW scale PEMWE is entering a phase where ... Current Modulation](https://reader031.vdocuments.net/reader031/viewer/2022021507/5b0766dc7f8b9ad5548e4ce8/html5/thumbnails/24.jpg)
24