recuperator energy of the future is already here

17
RECUPERATOR Established 1973 ENERGY OF THE FUTURE IS ALREADY HERE

Upload: antonia-holmes

Post on 18-Dec-2015

223 views

Category:

Documents


3 download

TRANSCRIPT

RECUPERATOREstablished 1973

ENERGY OF THE FUTUREIS ALREADY HERE

THE HEAT EXCHANGER

Recuperator factory at Rescaldina (Milano)

1973: Founded during first energy crisis 2007: New facility - Fully automated 2012: 50% Facility expansion

THE HEAT EXCHANGERFULLY AUTOMATED

THE HEAT EXCHANGER

Delivery Area

FASTEST DELIVERY

PRODUCTS Plate Heat Exchangers

Series B, F, A 7.8” to 94.9” single modules Up to 100,000 CFM modules 50 to 80% efficiency

Rotary Wheel Heat Exchangers Series T

19.7” to 90.5” diameters Up to 14,000 CFM 60 to 80% efficiency Sensible and/or Latent heat exchange

PLATE EXCHANGER FEATURES Series B, F, A

7.8” to 94.9” modules Up to 100,000 CFM modules Self-supporting design eliminates spacers 50 to 80% efficiency Folded, sealed and Crimped plate edges – very tight, stable alignment Multitude of options

THE HEAT EXCHANGER

Supply Air

Temperature Distribution

Exhaust Air

Temperature Distribution

Pressure Drop

Distribution

MOST EFFICIENTLEAST PRESSURE DROP

Plate Exchanger Materials & Treatments

Standard: Aircraft-grade Aluminum

Corrosion Resistant: Epoxy coated Aluminum

High Temperature: AISI 316L Stainless Steel

Plate Exchanger Options

Casing & End Plate Options:

TV: Painted casing

RF: Reinforced casing

AR: Galvanized end plates w/Slide-in corners

AE: Galvanized end plates w/Double fold for duct installation

AZ: Lightweight aluminum end plates

Plate Exchanger Options

By-Pass Options: BV: Lateral w/damper

and vertical blades BM: Lateral w/single blade BY: Lateral w/single internal

damper BL: Lateral w/short damper

and internal shaft BD: Lateral w/internal control

Plate Exchanger Installations

Quality Case in Point Columbia University

150,000 CFM AHUs on laboratory Engineer specified

400°F, 10” w.c., < 1% leakage

Recuperator produced units / tests in 4 weeks Certified at 400°F, 12” w.c. 0.002% leakage overall! 3 of 4 modules tested 0.000% - no

reading!

Engineer has changed all specifications to Recuperator

LABORATORY Two computerized wind tunnels

Meet ASHRAE & Eurovent

standards

Research & Development

Quality/Performance confirmation

PRODUCT SELECTION SOFTWARE

REX: Design/Selection software Designs plate/rotary heat

exchangers Generates technical data Calculates performance data Provides OEM Pricing End user payback calculations

ReCamB: dll file for incorporation into AHU manufacturer’s software.

RECUPERATORRecuperator USA

PO Box 10084Lancaster, PA 17605

Tel: 717-299-5679Cell: 717-917-3635

Email: [email protected]