red hat storage day new york - penguin computing spotlight: delivering open solutions with red hat...
TRANSCRIPT
DeliveringOpenSolu/onwithRedHatStorageandPenguinCompu/ng
RedHatStorageDays–October20th,2016
©2016PenguinCompu/ng.Allrightsreserved.
PENGUIN COMPUTING
• Pioneeringcompute,storageandnetworkingsolu5onsthatdelivertheadvantagesofopentechnologies
• PenguinCompu,ngcombines16yearsofLinuxexperiencewithsystemandso<waretechnologyinnova,ontoprovidebestofclassandbestvaluesolu,ons
MissionandVision
PENGUIN COMPUTING
TieredSupport,ProfessionalandManagedServices
CorporateFacts
OpenComputeand19”ServerSolu/ons
HighPerformanceandEnterpriseStorageSolu/ons
Management,CloudandRemoteDesktopSoOware
HighSpeedandSDNEthernetNetworks
Fremont,CAFacility:ISO9001Compliant55,000squarefeetFullBTO/CTOcapabili/esforserver,storage&fullyintegratedracks8,000units/250racks+permonth–1.5megawa[s;airandwatercoolinginfrastructure
In-houseproduc/on,burn-in,tes/ngandQAInstalla/onsin50countries;World-wideNBDsupportandserviceExtensivehardware/soOwareengineeringandR&Dcapability
OfficesinFremont,SanFrancisco,Atlanta,ManassasandWashingtonD.C.(2016)
PENGUIN COMPUTING
ScyldClusterWare
ScyldCloudWorksta/on
ScyldCloudManager
PrivateCloud
Integrated3rd-partysolu/ons
-Highperformancestorage
-Resourcemanagers
-Compilers&tools
Storage
Worksta/onsServers
HPCClusters
OPTIMIZEDFORLINUX END-TO-ENDSOFTWARESOLUTIONS HPCCLOUDCOMPUTING CUSTOMENGINEERING&SUPPORT
Rackmountservers
Storagesystemsandsolu/ons
Networking
Infrastructure
GPUsandIntelPhi
Professionalworksta/ons
Openstandardsbased
Op/mizedforscale
Customarchitectureanddesign
FullManagedServicescapability
Completefactoryintegra/on
Productlifecyclemanagement
Onsiteinstalla/onandtraining
WorldwideproductsupportbyLinuxexperts
Customizedserviceengagements
On-demand,hybrid,andmanaged
Fullworkflowop/mizedcloudCustomerSelf-management
B2BHPCsolu/ons
Extremelycosteffec/ve
PenguinHPCexper/se
LINUX-BASEDSYSTEMS INTEGRATEDSOFTWARE HPCASASERVICE PROFESSIONALSERVICES
UniqueBreadthofLinuxBasedSolu/ons
PENGUIN COMPUTING
• ISO9001Compliant55,000squarefootfacility• 2MWpower• FullBTO/CTOcapabili/es–Server/Rack• 8,000unitsor250racks+/month• Allproduc/on,tes/ng,QAin-house• Within10milesofallmajorsuppliers• Decadesofsystembuildingexperience• Op/mizedforQualityCustomSolu/ons• Fullproductlifecyclesupport• Revisioncontrol• CustomQ/A,packaging&Shipping
ManufacturingCapabili/esTurnkeyClustersServers
CustomIntegra/on FullServiceRackLevelIntegra/on
High-performanceWorksta/ons
EthernetSwitches
PENGUIN COMPUTINGPenguinCommitmenttoOpenTechnologies
©2015-2016PenguinCompu/ng.Allrightsreserved. 6
Tundra™ExtremeScaleOCPbenefitsappliedtoHPCDense,scalable,flexiblecompu/ngandstorageplamorm200+rackstobedeliveredtoDOEin2016
Arc5ca™EthernetSwitchesHighlyflexiblesoOwaredefinedTORswitches1,10,40and100GigEavailableLatestBroadcompacketengines
FrostByte™HSStorageApplianceHighlyavailable,high-speedstorageapplianceMul/plesoOwaresolu/ons(LustreoverZFS,Gluster,Ceph)OpendesignyieldsmaximumROI
Scyld™SoTwareSuiteClusterWare–clustermanagementstackCloudManager–OpenStack-basedHPCcloudmanagementCloudWorksta1on–3Daccelerated,browser-basedvirtualdesktop
PENGUIN COMPUTINGPenguinEndtoEndStorageSolu/ons
©2016PenguinCompu/ng.Allrightsreserved. 7
ValidatedHardware TurnkeySolu/ons ProfessionalServices
Tradi5onal19”StorageNodes
TundraESOCPStorageNodes OCPRackScale EIARackScale
Admin
ValidatedHardwareØ ValidatedStorageServersØ BareMetalØ FlexibleSupportOp/ons
Turn-keyStorageSolu/onsØ ValidatedandTestedHardwareØ RedHatStorageInstall&TuningØ FlexibleSupportOp/ons
ServiceSolu/onsØ Solu/onArchitectureØ PrivateCloudØ ManagedServices
PENGUIN COMPUTINGPenguinTradi/onalStorageSolu/ons
©2016PenguinCompu/ng.Allrightsreserved. 8
IceBreakerStorageServers
ValidatedHardwareØ ValidatedStorageServersØ BareMetalØ FlexibleSupportOp/onsFlexibleConfigura/onsforVariousWorkloadsRackScaleIntegratedandTurnkeySolu/ons
PENGUIN COMPUTINGCurrentIceBreakerLineup
9
2U
IB2912 IB2924 IB2912J IB2924J
4U
IB4924 IB4936 IB4960J
PENGUIN COMPUTING
• Relion–IntelTundraSled• RelionOCP1930g-IntelDualSocketE5-2600v3/4• RelionOCP1930e–IntelDualSocketE5-2600v3/4;• PCSDBasedMotherboard
• ARM–TundraSled• ValkreOCP1030c–DualCaviumThunderX
• Icebreaker–TundraStorageSled• IcebreakerOCP1905g–IntelSingleSocketE3-1200v3• IcebreakerOCP1906g–IntelSingleBroadwellXeon–DE
• IntelTundraAcceleratorSled• RelionPhiOCP1030-BootableXeonPhi(KNL)
PenguinTundraESServerOp/ons
PENGUIN COMPUTINGPenguinTundraESStorageSolu/ons
©2016PenguinCompu/ng.Allrightsreserved. 11
Relion–IntelTundraSledRelionOCP1930g-IntelDualSocketE5-2600v3/4
ARM–TundraSledValkreOCP1030c–DualCaviumThunderX
Icebreaker–TundraStorageSledIcebreakerOCP1905g–IntelSingleSocketE3-1200v3IcebreakerOCP1906g–IntelSingleBroadwellXeon–DE
Icebreaker–TundraStorageJBODIcebreakerOCP2945J–45Bay3.5”SAS/SATA12Gb/sJBOD
PENGUIN COMPUTING
KeyFeaturesThreeNodesin1OpenUFormFactorSingleSocketIntel®Broadwell-DED1541SOCUpto128GBDDR4-2133MHz(4xDIMMs)pernodeDedicatedBMC–AST24006xSATAPortsSupportstotal6xHDD(Max4x3.5”or4x2.5”)2xGbE/RJ45Op/onal2x10GbE/SFP+LOM
TundraESStorage-IcebreakerOCP1906g
PENGUIN COMPUTING
• 2OU• 45x3.5”SAS/SATAHDDs• 3xtraysholding15xHDDs• Eachtraycanbezonedas15or7xdrive• DualMini-SASHD12Gbconnectors
• SAS12Gb/s• MaxOpera/on–680W• ColdStorage–200W
TundraESStorage-IceBreakerOCP2945J
13
PENGUIN COMPUTING
HighLevelTickDataFlow
CaseStudy:FinancialDataAnaly/cs
©2016PenguinCompu/ng.Allrightsreserved. 14
PENGUIN COMPUTING
RedHatGlusterStorageSolu/onforHistoricalTickData
CaseStudy:FinancialDataAnaly/cs
©2016PenguinCompu/ng.Allrightsreserved. 15
PENGUIN COMPUTING
RedHatGlusterStorage–DisasterRecoveryImplementa/on
CaseStudy:FinancialDataAnaly/cs
©2016PenguinCompu/ng.Allrightsreserved. 16
PENGUIN COMPUTING
TotalClusterThroughputMeasuredOverA1HourPeriod(6secintervals)
CaseStudy:FinancialDataAnaly/cs
©2016PenguinCompu/ng.Allrightsreserved. 17
PENGUIN COMPUTING
• DeeperAnaly/cs:Lookfartherbackin/mebystoringmoredatawithgreatergranularity• LowerCost:CustomersswitchingfromstorageappliancesfromestablishedvendorstoRedHatGlusterStoragereportcostsavingsonsolu/onacquisi/onandongoingmaintenance• Be[erPerformance:Customersswitchingfrommonolithictradi/onalstoragesolu/onstoRedHatGlusterStoragefindasignificantgaininread/writeperformance• LowerRisk:Offsitestandbyisasynchronouslygeo-replicated
Benefits
©2016PenguinCompu/ng.Allrightsreserved. 18
©2016PenguinCompu/ng.Allrightsreserved.
Q&A
ThankYou
PENGUIN COMPUTING
• FlexibleOpenComputesolu/onforHPC,CloudandBigData• Greaterreliability,operabilityandefficiencythan19”solu/ons
• Airorwatercoolingavailable• 1OUor2OUsledconfigura/ons
• Compute,storageandacceleratorsleds• OpenBridgeRackDesignwithHighEfficiencyPowerShelves
• Singleordualpowerzones• Upto48kWw/N+2Redundancy• Powerpeakingviain-lineba[erymodules• IncludesRackPowerManagement
• RackconvertsbetweenEIA(19”)andOCP(21”)
TundraESOpenRack–Single/DualPowerZone
PENGUIN COMPUTING
• OCPBridgeRack–OCP21”orstandard19”wide• DualCPUComputePersonality• SingleCPUStorage/HadoopPersonality• GPUPersonality• XeonPhi–KnightsLandingPersonality• CaviumArmPersonality
TundraES–SingleSledSingleRackArchitecture
PENGUIN COMPUTING
• Highvoltage,3-phasepower(208,240or277V)• Highvoltagesmeanlowercurrent,smallerwires,fewerbreakers
• Distribu/ngpowertoallequipmentintherack12V• Voltageconversionstepseliminated,improvingpowerefficiency
• Powershelffeaturesapplytoallequipmentinrack• A/Bfeeds,ba[erybackup,N+1orN+3orN+N
• Powerinfrastructurecanbere-used• Drama/cROIimprovementsovermul/plegenera/onsofhardware
• Fewerpowersuppliesmeanfewerfailures• Reducedinfrastructurecostduringtechnologygenera/ontransi/on• Opera/onalcostsavings–Easeofmaintenance
TundraESPower
22
PENGUIN COMPUTING
• ShelfDimensions:3U(H)x483mm(W)x655mm(D)• Nine(9)3Ux1UslotsforRec/fiersandBBUs
• NEW:Rec/fierisbeingrecer/fiedat3.3kW• SinglePowerSystemOutput(Max)=26.4kW(N+1)
• ULLis/ngandSafety• OCPRack,PowerShelves,andBusBarshavebeensenttoBACLforULLis/ng
asacompletesystem(allcomponentsareULRecognized)• AlsoaddingshroudsaroundDCconnec/onsfromshelftoBusBar• PhysicalDCPower-offSwitchwillbeadded
TundraESOCPPowerManagement
PENGUIN COMPUTING
• Allserviceisdonefromthefrontorcoldaisle• Nosharedcooling.Eachserverdoesit’sownfanspeedcontrol.• Rearofrackisavailableformul/plecoolingop/ons
• Standardchilledaircooling• Possiblyusingfreeaircoolingandhigherdatacentertemperatures
• Watercoolingwithradiatordooronrearofrack• Chilledorwarmwaterop/ons• 35kWdesignsfromMo/vair
• Liquidcoolingdirecttochip• Usesopenareabesidebus-barforwatermanifoldandquickconnect• Especiallysuitedtowarmwatercooling• Simpleliquidlooptoexteriorradiator
TundraESCoolingOp/ons
PENGUIN COMPUTING
• Delivershigh-performancecoolingliquiddirectlytotheho[estelementsintheserver:
• >50%lowercoolingenergy• 5-10%lowerITenergy• 20-30%lowertotaldatacenterenergy• 2.5x-5xincreaseinserverdensity• Increasedserverperformance• Increasedserverreliability• Increasedserverup-/me
TundraESDirecttoChipLiquidCooling
25
PENGUIN COMPUTING
KeyFeatures• DualSocketIntel®E5-2600v3Series
• Upto1TBDDR4-2133MHz(16xDIMMs)• Intel®C612Chipset(Wellsburg)
• 2xGigE/RJ45(Intel®I350)• 1xDedicatedBMC(MatroxG200eW)
• 3xPCIex16Gen3slot• 3xPCIex8Gen3slot
• 36x3.5”HotswapSAS/SATAHDDBay• SAS12Gb/s
• Redundant1280W80PlusPla/numPSU(120-240VAC)• Dimensions:27.5”x17.2”x7.0”
IceBreaker4936