refer e2/as1 table 7 5mm gap max.for notchedturn-down · pdf file5mm gap max.for...
TRANSCRIPT
SCALE 1:5
ROOF
STRUCTURE
7.5/9.0mm REBATED SHEET OVER
20mm DRAINED CAVITY - FIX IN
ACCORDANCE TO MANUF. DETAILS
75
35
R
E
F
E
R
E
2
/A
S
1
T
A
B
L
E
7
5
m
m
G
A
P
M
A
X
.
F
O
R
N
O
T
C
H
E
D
T
U
R
N
-D
O
W
N
STOARMAT RENDER SYSTEM
STO uPVC CLIP ON TRAY -
REMOVE BACK TAB IF REQ.
uPVC CAVITY CLOSER
UNDERLAY OR FLASHING TAPE
LAPPED OVER APRON FLASHING
UPSTAND
PRE FINISHED METAL APRON
FLASHING
PREFINISHED METAL ROOFING
OVER UNDERLAY
SELECTED ROOF WRAP
ROOF UNDERLAY
CONTINUOUS TO TOP OF
FLASHING
STOPEND TO RUN 10mm
MIN.PAST CLADDING
NOTE:
STOPENDS REQUIRED AT ROOF to WALL
JUNCTION TO DIVERT WATER FROM CAVITY
The information contained on this page is based on our experience and research at the date of issue. The detail is for use by Registered
Architects, Licensed Designers or Chartered Engineers to assist in developing project details using Sto Systems. Stoanz Ltd reserve the right to
alter or update information at any time without prior notice and it is the responsibility of the designer, project manager or Sto contractor to insure
they have and use the current Sto details and specifications on site.
STO/
MONOTEK
STOARMAT RENDER SYSTEM
APRON (TRANSVERSE) FLASHING
FCS 700
2017
SCALE 1:5
75
35
ROOF RAFTER
REFER E2/AS1 TABLE 7
uPVC CAVITY CLOSER
7.5/9.0mm REBATED SHEET OVER 20mm
DRAINED CAVITY - FIX IN ACCORDANCE
WITH MANUF. DETAILS
STOARMAT RENDER SYSTEM
STO uPVC CLIP ON TRAY -
REMOVE BACK TAB IF REQ.
UNDERLAY OR FLASHING TAPE
LAPPED OVER APRON
FLASHING UPSTAND
APRON FLASHING WITH TAPERED
DIVERTER FLASHING TO DIRECT WATER
INTO GUTTER. CLADDING TO BE
CAREFULLY CUT OVER STOPEND &
SEALED
NOTE: PROVIDE DIVERTER FLASHING AT ROOF TO
GUTTER JUNCTION TO DIVERT WATER INTO THE
GUTTER - Refer Drawing FCS 606 (Monotek)
The information contained on this page is based on our experience and research at the date of issue. The detail is for use by Registered
Architects, Licensed Designers or Chartered Engineers to assist in developing project details using Sto Systems. Stoanz Ltd reserve the right to
alter or update information at any time without prior notice and it is the responsibility of the designer, project manager or Sto contractor to insure
they have and use the current Sto details and specifications on site.
STO/
MONOTEK
STOARMAT RENDER SYSTEM
APRON (PARALLEL) FLASHING
FCS 701
2017
SCALE 1:5
20mm DRAINED CAVITY
5
m
m
G
A
P
M
A
X
.
F
O
R
N
O
T
C
H
E
D
T
U
R
N
-D
O
W
N
7.5/9.0mm REBATED SHEETS - FIX
IN ACCORDANCE WITH MANUF.
DETAILS
VENTED CAVITY CLOSURE -
STO uPVC CLIP ON TRAY
STOARMAT RENDER SYSTEM
PREFINISHED METAL
APRON FLASHING
PREFINISHED METAL
ROOFING OVER UNDERLAY
SELECTED ROOF UNDERLAY
ROOF UNDERLAY
CONTINUOUS TO TOP OF
FLASHING
NOTE: CONTRACTOR TO FIT STOPEND FLASHING & HEMMED
FLASHING FOR FASCIAS 50mm BEHIND CLADDING, 50mm BEHIND
FASCIA. STO CONTRACTOR TO APPLY FINISHED SEALANT JOINT
BETWEEN FASCIA & PLASTER. UNDERLAY or FLASHING TAPE OVER
FLASHING UPSTAND.
PARAPETS - REFER 500 SERIES - PARAPET DETAILS
50mm MIN.FASCIA BACK
FLASHING - SHOWN DASHED
STOPEND FLASHING
75
35
R
E
F
E
R
E
2
/A
S
1
T
A
B
L
E
7
5
m
m
G
A
P
M
A
X
.
F
O
R
N
O
T
C
H
E
D
T
U
R
N
-D
O
W
N
The information contained on this page is based on our experience and research at the date of issue. The detail is for use by Registered
Architects, Licensed Designers or Chartered Engineers to assist in developing project details using Sto Systems. Stoanz Ltd reserve the right to
alter or update information at any time without prior notice and it is the responsibility of the designer, project manager or Sto contractor to insure
they have and use the current Sto details and specifications on site.
STO/
MONOTEK
STOARMAT RENDER SYSTEM
INTERSTOREY TRANSVERSE (APRON) ROOF STOPEND
FCS 702
2017
SCALE 1:5
STOP END 10mm PAST
FINISHED CLADDING
20mm DRAINED
CAVITY
MEMBRANE OVER COVER
BOARD WITH DRIP EDGE
10
10
7.5/9.0mm REBATED SHEET -
FIX IN ACCORDANCE WITH
MANUF. DETAILS
STOARMAT RENDER SYSTEM
35
75
15
0
FASCIA 10mm SHORT OF
FINISHED CLADDING WITH MS
SEALANT JOINT
BACK FLASHING 50mm BEHIND
FASCIA & CLADDING
STO STICK ON CONNECTOR or MS
SEALANT JOINT ON PEF ROD
BETWEEN STOPEND AND CLADDING
ROOFING MEMBRANE OVER METAL
STOPEND. STOPEND TO EXTEND 10mm
MIN.PAST FINISHED WALL
ROOFING MEMBRANE 150mm
MIN.UPSTAND, 75mm CLADDING COVER,
CLADDING 35mm MIN. ABOVE MEMBRANE
11
0
34
76
15
0
1
0
BATTEN TO BLOCK CAVITY
I
F
M
E
M
B
R
A
N
E
I
F
R
O
O
F
C
L
A
D
D
I
N
G
R
O
O
F
/
D
E
C
K
NOTE: MEMBRANE NOT SHOWN ON STOP
END FOR CLARITY
A = CAVITY & FINISHED CLADDING + 10mm
7
5
m
m
M
I
N
.
A
The information contained on this page is based on our experience and research at the date of issue. The detail is for use by Registered
Architects, Licensed Designers or Chartered Engineers to assist in developing project details using Sto Systems. Stoanz Ltd reserve the right to
alter or update information at any time without prior notice and it is the responsibility of the designer, project manager or Sto contractor to insure
they have and use the current Sto details and specifications on site.
STO/
MONOTEK
STOARMAT RENDER SYSTEM
INTER-STOREY FLAT (MEMBRANE)ROOF STOPEND
FCS 703
2017
SCALE 1:5
WALL UNDERLAY
TIMBER FRAMING TO
NZS 3604
20mm DRAINED
CAVITY
7.5/9.0mm REBATED SHEET -
FIX IN ACCORDANCE WITH
MANUF. DETAILS
STOARMAT RENDER SYSTEM
FASCIA 10mm SHORT OF
CLADDING MS SEALANT JOINT
FASCIA / CLADDING BACK
FLASHING, MIN 50mm COVER
H3.1 PRE PRIMED & PAINTED
FASCIA/BARGE BOARD -
SHOWN DASHED
10
PRE FINISHED METAL FLASHING
OVER FASCIA
APRON FLASHING
STOPEND
The information contained on this page is based on our experience and research at the date of issue. The detail is for use by Registered
Architects, Licensed Designers or Chartered Engineers to assist in developing project details using Sto Systems. Stoanz Ltd reserve the right to
alter or update information at any time without prior notice and it is the responsibility of the designer, project manager or Sto contractor to insure
they have and use the current Sto details and specifications on site.
STO/
MONOTEK
STOARMAT RENDER SYSTEM
INTER-STOREY ROOF STOPEND - PLAN VIEW
FCS 704
2017
75
50
DRESS WALL
UNDERLAY OVER
GUTTER LINING
SELECTED GUTTER LINING CARRIED
OVER ANTI-PONDING BOARD AND UP
ABUTMENT FRAME ON NOG TO SUIT
GUTTER BOARD AT ABUTMENT
ON NOGS TO SUIT
ANTI-PONDING BOARD
LAID TO A FALL
ROOF UNDERLAY
CARRIED DOWN
OVER GUTTER LINING
MASONRY
ROOFING TILE
SCALE 1:5
STO uPVC
CLIP ON TRAY
100mm MIN.
20mm DRAINED CAVITY
7.5/9.0mm REBATED SHEET -
FIX IN ACCORDANCE TO
MANUF. DETAILS
STOARMAT RENDER SYSTEM
The information contained on this page is based on our experience and research at the date of issue. The detail is for use by Registered
Architects, Licensed Designers or Chartered Engineers to assist in developing project details using Sto Systems. Stoanz Ltd reserve the right to
alter or update information at any time without prior notice and it is the responsibility of the designer, project manager or Sto contractor to insure
they have and use the current Sto details and specifications on site.
STO/
MONOTEK
STOARMAT RENDER SYSTEM
ROOF PENETRATION/GUTTER (Masonry Tile) DETAIL
FCS 705
2017
SCALE 1:5
80mm MIN. 80mm MIN.
20m
m M
IN
.
110m
m
NOTE: WHERE GUTTER FINISHES WITHIN THE LENGTH OF THE WALL, STEP LOWER PART OF
GUTTER OUT TO 10mm PAST THE CLADDING LINE, WHILE MAINTAINING REQ.CLEARANCES, TO
ALLOW THE GUTTER TO FEED INTO THE LOWER EAVES GUTTER.
- REFER Fig: 37 & Fig: 50 Incl.Section 8.1.6.2
35m
m G
AP
75m
m M
IN
.C
OV
ER
MIN
.T
OT
AL
WALL UNDERLAY OVER
GUTTER UPSTAND
PREFINISHED METAL GUTTER
STO uPVC VENTED CAVITY
CLOSER & STO uPVC CLIP ON
TRAY
20mm DRAINED CAVITY
7.5/9.0mm REBATED SHEET -
FIX IN ACCORDANCE WITH
MANUF. DETAILS
STOARMAT RENDER SYSTEM
The information contained on this page is based on our experience and research at the date of issue. The detail is for use by Registered
Architects, Licensed Designers or Chartered Engineers to assist in developing project details using Sto Systems. Stoanz Ltd reserve the right to
alter or update information at any time without prior notice and it is the responsibility of the designer, project manager or Sto contractor to insure
they have and use the current Sto details and specifications on site.
STO/
MONOTEK
STOARMAT RENDER SYSTEM
PARALLEL ROOF/HIDDEN GUTTER
FCS 706
2017
SCALE 1:5
WALL UNDERLAY
20mm DRAINED CAVITY
7.5/9.0mm REBATED SHEET -
FIX IN ACCORDANCE WITH
MANUF. DETAILS
STOARMAT RENDER SYSTEM
6mm
MAX.GAP
50/90mm LAP REFER NZBC,
TABLE 7 E2/AS1 FOR
FLASHING DIMENSIONS
H3.1 PRE PRIMED & PAINTED
FASCIA/BARGE BOARD
PRE FINISHED METAL
FLASHING
MS SEALANT ON PEF ROD FOR
EXPOSED SITES
ALLOW FOR STO uPVC CLIP
ON FLASHING
PRE FINISHED METAL ROOFING
OVER ROOF UNDERLAY
50 cover
The information contained on this page is based on our experience and research at the date of issue. The detail is for use by Registered
Architects, Licensed Designers or Chartered Engineers to assist in developing project details using Sto Systems. Stoanz Ltd reserve the right to
alter or update information at any time without prior notice and it is the responsibility of the designer, project manager or Sto contractor to insure
they have and use the current Sto details and specifications on site.
STO/
MONOTEK
STOARMAT RENDER SYSTEM
FACE FIXED FASCIA/BARGE
FCS 707
2017
SCALE 1:5
20mm DRAINED CAVITY
TIMBER FRAMING
TO NZS3604
SELECTED MEMBRANE FINISH
OVER H3 "C" FACED PLYWOOD LAID
TO 1:30 MIN.FALL. GLUE & SCREW
TO TIMBER JOISTS, ALL EDGES
SUPPORTED ON FRAMING
TAKE BOTH LAYERS 6mm PAST
S/S ANGLE TO FORM DRIP EDGE
MIN.5mm RADIUS
TO PLYWOOD
PREFINISHED METAL SPOUTING
AND BRACKETS
WALL UNDERLAY
50mm MIN. LAP REFER E2/AS1
H3.1 PRE PRIMED & PAINTED
FASCIA/BARGE BOARD
MS SEALANT ON PEF ROD
STOARMAT RENDER
SYSTEM
7.5/9.00mm REBATED SHEET -
FIX IN ACCORDANCE WITH
MANUF. DETAILS
The information contained on this page is based on our experience and research at the date of issue. The detail is for use by Registered
Architects, Licensed Designers or Chartered Engineers to assist in developing project details using Sto Systems. Stoanz Ltd reserve the right to
alter or update information at any time without prior notice and it is the responsibility of the designer, project manager or Sto contractor to insure
they have and use the current Sto details and specifications on site.
STO/
MONOTEK
STOARMAT RENDER SYSTEM
FACE FIXED FASCIA/MEMBRANE ROOF
FCS 708
2017
SCALE 1:5
ROOF
STRUCTURE
PREFINISHED METAL
FLASHING, TURN DOWN TO
SUIT PROFILE
PREFINISHED METAL
ROOFING OVER UNDERLAY
SELECTED ROOF WRAP
50/90mm LAP REFER NZBC,
TABLE 7 E2/AS1 FOR
FLASHING DIMENSIONS
H3.1 PRE PRIMED & PAINTED
FASCIA/BARGE BOARD
PRE FINISHED METAL
FLASHING
MS SEALANT ON PEF ROD FOR
EXPOSED SITES
R
E
F
E
R
E
2
/A
S
1
T
A
B
L
E
7
WALL UNDERLAY
20mm DRAINED CAVITY
7.5/9.0mm MONOTEK
STOARMAT RENDER SYSTEM
The information contained on this page is based on our experience and research at the date of issue. The detail is for use by Registered
Architects, Licensed Designers or Chartered Engineers to assist in developing project details using Sto Systems. Stoanz Ltd reserve the right to
alter or update information at any time without prior notice and it is the responsibility of the designer, project manager or Sto contractor to insure
they have and use the current Sto details and specifications on site.
STO/
MONOTEK
STOARMAT RENDER SYSTEM
ROOF/WALL RIDGE
FCS 709
2017
PENETRATION APRON FLASHING
HEM FOLD UNDER ROOFING
SEPARATE ROOFING SHEET
OVER
MIN. UPSTAND 110mm
SIDE COVER
= 2 CRESTS
STOARMAT RENDER SYSTEM
WITH PREMESHED EXTERNAL
CORNERS
H3.1 TIMBER CAVITY BATTENS
FIBRE CEMENT SHEET
WALL CLADDING
35mm GAP BETWEEN
CLADDING AND FLASHING
SET ONE CORNER OF UPSTAND
HIGHER UP ROOF PLANE
TO PROVIDE CROSS FALL
2
5
0
m
m
M
I
N
.
11
0
35
1
3
0
-
2
0
0
1
3
0
-
2
0
0
COVER 130 - 200mm MAX.
REFER TO E2/AS3 Table 7
11
0
NOTE:
SUITABLE FOR RECTANGULAR PENETRATIONS UP TO 1200mm
WIDE.
ROOF PITCH MUST BE 10° or HIGHER - REFER TO E2/AS1
TABLE 9 or 17 FOR MAX.ROOF LENGTH ABOVE PENETRATIONS.
BLOCKING REQUIRED FOR PENETRATIONS OVER 200mm
FRAMED CHIMNEY
SCALE 1:20
UNDERLAY SEPARATOR BETWEEN
FLASHING AND FRAMING. FRAME TO
SUPPORT FLASHING
PREFINISHED METAL ROOFING
OVER UNDERLAY
SELECTED ROOF WRAP
E2/AS3 COMPLIANT METAL APRON
FLASHING
STO uPVC CLIP ON FOOT
TRAY
SECTION/FRAMED CHIMNEY
SCALE 1:10
75
35
35
75
110
110
STOARMAT RENDER SYSTEM OVER 7.5-9.0mm
FIBRE CEMENT SHEET
20mm DRAINED CAVITY
WALL UNDERLAY LAPS OVER
FLASHING
The information contained on this page is based on our experience and research at the date of issue. The detail is for use by Registered
Architects, Licensed Designers or Chartered Engineers to assist in developing project details using Sto Systems. Stoanz Ltd reserve the right to
alter or update information at any time without prior notice and it is the responsibility of the designer, project manager or Sto contractor to insure
they have and use the current Sto details and specifications on site.
STO/
MONOTEK
STOARMAT RENDER SYSTEM
FRAMED CHIMNEY OR PENETRATION UP TO 1200mm
FCS 710
2017