Registered Office: GUYANA POWER & LIGHT, Inc., 38 40, Main Street, Cummingsburg, Georgetown, Guyana Telephone: 592-226-2600-9 Fax: 592-227-1978 ANNEX 257/259 Middle Street, Cummingsburg, Georgetown, Guyana Telephone: 592-226-0565 / 66/68 Fax: 592-226-9821 March 08, 2016 Prospective Bidders Procurement of Operational Spares - 69/13.8kV Substations Contract Number GPL - PI - 018- 2016 ADDENDUM No. 1 Please find attached an addendum on the above contract. This addendum forms part of the contract and must be included in your bid submission. Please acknowledge receipt of this addendum in the Bid Submission Form. Should you require any further clarifications, do not hesitate to contact Mr. Navin Deonarayan, Project Engineer, Projects Management Department, Guyana Power & Light Inc. @ 257/259 Middle Street, Cummingsburg, Georgetown, Tel. 629-3622 or 227-4482, [email protected] Yours sincerely GUYANA POWER & LIGHT INC. Lennox McGreggor Projects Manager

Upload: others

Post on 16-Mar-2020

7 views

Category:

Documents


0 download

TRANSCRIPT

Registered Office: GUYANA POWER & LIGHT, Inc.,

38

40, Main Street, Cummingsburg, Georgetown, Guyana Telephone: 592-226-2600-9 Fax: 592-227-1978

ANNEX 257/259 Middle Street, Cummingsburg, Georgetown, Guyana

Telephone: 592-226-0565 / 66/68 Fax: 592-226-9821

March 08, 2016

Prospective Bidders

Procurement of Operational Spares - 69/13.8kV Substations

Contract Number GPL - PI - 018- 2016

ADDENDUM No. 1

Please find attached an addendum on the above contract. This addendum forms part of the contract and must

be included in your bid submission.

Please acknowledge receipt of this addendum in the Bid Submission Form.

Should you require any further clarifications, do not hesitate to contact Mr. Navin Deonarayan, Project

Engineer, Projects Management Department, Guyana Power & Light Inc. @ 257/259 Middle Street,

Cummingsburg, Georgetown, Tel. 629-3622 or 227-4482, [email protected]

Yours sincerely

GUYANA POWER & LIGHT INC.

Lennox McGreggor

Projects Manager

Registered Office: GUYANA POWER & LIGHT, Inc.,

39

40, Main Street, Cummingsburg, Georgetown, Guyana Telephone: 592-226-2600-9 Fax: 592-227-1978

ANNEX 257/259 Middle Street, Cummingsburg, Georgetown, Guyana

Telephone: 592-226-0565 / 66/68 Fax: 592-226-9821

Procurement of Operational Spares - 69/13.8kV Substations

Contract Number GPL - PI - 018- 2016

Addendum No.1

This addendum addresses a clarification requested on 03-010-2016 and now forms part of the bidding and

contract documents and modifies the original bidding documents.

Kindly acknowledge receipt of this addendum in the space provided in the Bid Submission Form. Failure to

do so may subject Bidder to disqualification.

AMENDMENTS/CLARIFICATIONS OF “Instruction to Tenderers”, Procurement of Operational

Spares - 69/13.8kV Substations.

a. Closing date for the submission of Bids for Procurement of Operational Spares - 69/13.8kV

Substations has been extended to March 30, 2016 at 14:00 hours.

b. The TECHNICAL AND GENERAL REQUIREMENTS is amended.

c. Appendix I is included.

TECHNICAL AND GENERAL REQUIREMENTS

CONTENTS

1.01 SCOPE 40

1.02 STANDARDS 40

1.03 COMPLIANCE WITH SPECIFICATION 40

1.04 COMPLIANCE WITH REGULATIONS 41

1.05 SERVICE CONDITIONS 42

1.06 SYSTEM CONDITIONS 43

Registered Office: GUYANA POWER & LIGHT, Inc.,

40

40, Main Street, Cummingsburg, Georgetown, Guyana Telephone: 592-226-2600-9 Fax: 592-227-1978

ANNEX 257/259 Middle Street, Cummingsburg, Georgetown, Guyana

Telephone: 592-226-0565 / 66/68 Fax: 592-226-9821

1.07 QUALITY ASSURANCE 43

1.08 INSPECTION AND TESTING – GENERAL 44

1.09 TYPE TESTS AND ROUTINE TESTS 45

1.10 REJECTION 46

1.11 CORROSION PROTECTION 47

1.12 NON CORRODING FASTENERS 47

1.13 SAFETY 48

1.14 HAZARDOUS SUBSTANCES 48

1.15 SPARE PARTS 48

1.16 SPECIAL TOOLS 48

1.17 PACKING AND SHIPPING 48

1.18 LABELS 49

1.19 GUARANTEE 50

1.20 SUBMITTALS WHICH FORM PART OF THE BID 50

1.21 SUBMITTALS AFTER CONTRACT AWARD 50

1.22 COMPLETENESS OF SUPPLY 51

Registered Office: GUYANA POWER & LIGHT, Inc.,

41

40, Main Street, Cummingsburg, Georgetown, Guyana Telephone: 592-226-2600-9 Fax: 592-227-1978

ANNEX 257/259 Middle Street, Cummingsburg, Georgetown, Guyana

Telephone: 592-226-0565 / 66/68 Fax: 592-226-9821

SPECIFICATION: TECHNICAL AND GENERAL REQUIREMENTS

1.01 SCOPE

A. General

This specification covers Technical and General Requirements for Procurement of

Operational Spares –69/13.8kV Substations.

“Equipment” shall include Materials, Goods and Services.

B. Associated Specifications

This Specification shall be associated with each of the Equipment Standards listed in

Appendix 1.

1.02 STANDARDS

A. Standards of General Application

Standards of General Application include – but are not limited to – the following

(Short Title):

ANSI C84.1 Voltage Ratings for Electrical Power Systems

IEC 617 Graphic Symbols for Drawings

B. Standards of Particular Application

Equipment shall be manufactured and tested in accordance with the Standards of Particular

Application, listed in Appendix 1.

C. Alternative Standards

The Bidder may propose alternative standards, provided it is demonstrated that they give a

degree of quality equivalent to that of the referenced standards. Acceptability of any

alternative standard is at the discretion of the Procuring Entity.

1.03 COMPLIANCE WITH SPECIFICATION

Registered Office: GUYANA POWER & LIGHT, Inc.,

42

40, Main Street, Cummingsburg, Georgetown, Guyana Telephone: 592-226-2600-9 Fax: 592-227-1978

ANNEX 257/259 Middle Street, Cummingsburg, Georgetown, Guyana

Telephone: 592-226-0565 / 66/68 Fax: 592-226-9821

All equipment offered shall comply fully with the requirements of this Specification and the

Specification applicable to the item. Any minor departure must be disclosed at the time of

Bidding in the Non-Compliance Schedule included in each Specification.

1.04 COMPLIANCE WITH REGULATIONS

All equipment and accessories shall comply in every respect with the Regulations and Acts in

force in Guyana.

Bidders shall acquaint themselves with such Regulations. In case of difficulty, the Procuring

Entity will provide assistance.

1.05 SERVICE CONDITIONS

The equipment shall be suitable for installation in the 69/13.8KV Substations having the

characteristics described below:

Environmentally, the region where the equipment is being installed is tropical. It includes

coastal areas subject to high relative humidity, which can give rise to condensation, and on-

shore winds will frequently be salt-laden. On occasions, the combination of salt and

condensation may create pollution conditions for outdoor equipment including insulators.

Therefore, outdoor material and equipment shall be: A. Designed

B. Protected

– for use in an exposed, heavily polluted, salty, corrosive and humid tropical coastal atmosphere.

The Supplier shall comply fully with the requirements of this Specification and associated

ASTM A123 or BS729 “Hot-dip Galvanizing” in the provision of the necessary corrosion

protection

Registered Office: GUYANA POWER & LIGHT, Inc.,

43

40, Main Street, Cummingsburg, Georgetown, Guyana Telephone: 592-226-2600-9 Fax: 592-227-1978

ANNEX 257/259 Middle Street, Cummingsburg, Georgetown, Guyana

Telephone: 592-226-0565 / 66/68 Fax: 592-226-9821

Table 1. Service Conditions

Altitude

Maximum daily mean temperature

Maximum outdoor ambient shade temperature

Design Temperature for Equipment Rating

Minimum outdoor ambient shade temperature

Maximum relative humidity

Wind Velocity

Isokeraunic level

Average Number of days with Rain p.a.

Average Annual rainfall, cm

: <1000m above sea-level

: 30° C

: 40° C

: 40° C

: 15° C

: 100%

: 30 kph

: 70

:120

: 150

Registered Office: GUYANA POWER & LIGHT, Inc.,

44

40, Main Street, Cummingsburg, Georgetown, Guyana Telephone: 592-226-2600-9 Fax: 592-227-1978

ANNEX 257/259 Middle Street, Cummingsburg, Georgetown, Guyana

Telephone: 592-226-0565 / 66/68 Fax: 592-226-9821

1.06 SYSTEM CONDITIONS

All equipment shall be rated not less than the requirements of the 60 Hz system parameters as

outlined below:

Nominal System Voltage: 69 KV 13.8 KV

LV Single

Phase

120/240 V

LV Three

Phase

240/480 V

(see note 1)

125 VDC

Maximum System voltage: 75 KV 15 KV 125/250 250/500 131VDC

Nominal Short Circuit

Levels:

12.6 KA 35 KA 16 KA 16 KA

Insulation Levels

BIL:

Power Frequency 1 min.:

350 KV

160 KV

95 KV

34 KV

30 KV

10 KV

30 KV

10 KV 1000 VDC

Creepage 25mm/kV

Neutral Grounding

Arrangements:

Star connected

with directly

grounded neutral

Delta

connected

(grounded

through zigzag

transformer)

Solidly

Grounded

Solidly

Grounded

Table 2. System Conditions

Voltage spread to ANSI C84.1 - 'Voltage Ratings for Electrical Power Systems'.:

Note 1: Other 3-phase voltages may also be applicable for special applications where so specified.

Registered Office: GUYANA POWER & LIGHT, Inc.,

45

40, Main Street, Cummingsburg, Georgetown, Guyana Telephone: 592-226-2600-9 Fax: 592-227-1978

ANNEX 257/259 Middle Street, Cummingsburg, Georgetown, Guyana

Telephone: 592-226-0565 / 66/68 Fax: 592-226-9821

1.07 QUALITY ASSURANCE

A. Quality Assurance governing the Supply

Details of the Quality Assurance governing Supply of Equipment shall be submitted with the Bid

and shall typically include details such as:

The Structure of the Organization and the Independence of the QA function.

The System for Purchasing, Taking Delivery and Verification of Quality of

Materials;

The System for Ensuring Quality of workmanship;

Proposed Subcontractors who shall be Subject to Procuring Entity’s Approval

The System for QA of Sub-contractors equal to the Bidder’s

Hold and Notification Points;

Final Inspection and Test.

B. Manufacturer’s Certification

If Manufacturers are certified to a recognized Quality Management and Quality Assurance

Standards such as ISO 9001 or ISO 9002, such certification shall be submitted as part of the

bid documentation.

1.08 INSPECTION AND TESTING - GENERAL

Full details of proposed tests, including connection diagrams and drawings, shall be submitted

for the Procuring Entity’s approval, at least one month before testing.

In the case of components for which specific type tests or routine tests are not given in this

specification, the Supplier shall include a list and details of the tests normally required for these

components.

If the Procuring Entity does not indicate his intention to participate in the testing, the

manufacturer may proceed with the tests and shall furnish the results thereof to the Procuring

Entity.

No inspection or lack of inspection or passing by the Procuring Entity’s representative of

equipment or materials shall relieve the Supplier from his liability to complete the supply in

accordance with the order and this specification.

Registered Office: GUYANA POWER & LIGHT, Inc.,

46

40, Main Street, Cummingsburg, Georgetown, Guyana Telephone: 592-226-2600-9 Fax: 592-227-1978

ANNEX 257/259 Middle Street, Cummingsburg, Georgetown, Guyana

Telephone: 592-226-0565 / 66/68 Fax: 592-226-9821

The Supplier shall submit to the Procuring Entity two signed copies of test certificates.

The test certificates must:

- Show actual test values, and not merely confirm that requirements have been met.

- Include the date on which the tests were carried out

- Include the Procuring Entity’s order No.

- For items with serial numbers such as bushings, etc., - give the serial numbers included in the

consignment and the serial numbers of the test samples.

No materials shall be dispatched until the test certificates have been received by the Procuring

Entity and the Supplier has been informed that they are acceptable.

All materials supplied shall have successfully met the Quality Assurance, Type and Routine

Testing and Other Requirements of this “General and Technical Requirements” Specification

and its associated Specific Equipment Specifications listed in Appendix 1.

The Supplier shall be responsible for the proper testing of the plant or materials supplied by

sub-Suppliers to the same extent as if the plant or materials were completed or supplied by

the Supplier.

The Procuring Entity shall have free entry at all times, while work on the order is being

performed, to all parts of the manufacturer's works, or sub-Supplier’s works which concern the

processing of the equipment ordered. The manufacturer shall afford the Procuring Entity without

charge, all reasonable facilities to ensure that the equipment being furnished is in accordance

with this specification.

The Procuring Entity may decide to have the equipment tested after reception. The supplier shall

co-operate with this inspection and shall provide to the Procuring Entity, free of charge, all the

facilities which the latter may require.

The Procuring Entity shall have the right, if he so chooses, to review Design Analysis and

Calculations (where, for example, in the opinion of the Procuring Entity, the adequacy of the

Design is not adequately demonstrated by other Submittals or by the Type or Routine Tests).

Prices for Type Tests, or Additional Type Tests, shall be quoted as a separate item, if

requested.

All routine and Special or Sample Tests required by this Specification shall be carried out at the

expense of the Supplier.

The Procuring Entity shall cover his own costs arising from attendance at tests.

1.09 TYPE TESTS AND ROUTINE TESTS

Registered Office: GUYANA POWER & LIGHT, Inc.,

47

40, Main Street, Cummingsburg, Georgetown, Guyana Telephone: 592-226-2600-9 Fax: 592-227-1978

ANNEX 257/259 Middle Street, Cummingsburg, Georgetown, Guyana

Telephone: 592-226-0565 / 66/68 Fax: 592-226-9821

A. Type Tests

Type Tests are specified in the Associated Specifications listed in Appendix 1

A list of Type Tests completed, and copies of Type Test Certificates shall be submitted with the

Bid.

B. Routine Tests

Routine tests are specified in the Associated Specifications listed in Appendix 1.

A list of Proposed Routine Tests and Sample Copies of Routine Test Certificates shall be

submitted with the Bid

C. Special or Sample Tests

Special or Sample tests shall be at the Procuring Entity’s option. Such Tests shall be carried out

in accordance with the requirements of the specific Equipment / Materials Specifications and

Standards.

1.10 REJECTION

The Procuring Entity reserves the right to reject equipment or to demand modifications to

equipment if the test results do not comply with the values specified or with the data given in

the technical data schedule.

If more than 10% of a particular consignment fails to meet any of the requirements of this

Specification, the Procuring Entity shall be free to reject the whole consignment. On no

account shall any rejected consignment, or part thereof be again presented for test unless with

the written approval of and under conditions determined by the Procuring Entity.

In the event of disagreement arising between Procuring Entity and Supplier as to Quality of

Equipment or Material, the matter shall be referred to an Independent Testing Laboratory

mutually agreed upon for test under specified conditions. The Report of such Test shall be final

and the expense shall be borne by the party against whom the decision is given.

1.11 CORROSION PROTECTION

A. Corrosion Protection Standard

Given the highly corrosive environmental conditions, the highest importance is attached to

the adequacy of the Supplier’s Proposed Corrosion Protection Systems.

Registered Office: GUYANA POWER & LIGHT, Inc.,

48

40, Main Street, Cummingsburg, Georgetown, Guyana Telephone: 592-226-2600-9 Fax: 592-227-1978

ANNEX 257/259 Middle Street, Cummingsburg, Georgetown, Guyana

Telephone: 592-226-0565 / 66/68 Fax: 592-226-9821

The Supplier shall use a recognized National or International Standard to define the

Corrosion Protection he proposes to meet these highly corrosive conditions.

B. Hot-dip Galvanizing

All ferrous materials and all ferrous components of accessories and fittings shall be hot-dip

galvanized, in accordance with the ASTM A123 or BS729: “Hot-Dip Galvanizing” – unless the

ferrous material is stainless steel.

High tensile steel nuts, bolts and spring washers shall be electro-galvanized.

C. Other Corrosion Protection and Painting Systems

Where Hot-dip Galvanizing of ferrous materials is clearly not feasible, other methods of

corrosion protection shall be proposed by the Bidder, for approval by the Procuring Entity

D. Confirmation of Corrosion Protection

The Supplier shall furnish a Statement, as a submittal forming part of the Bid, confirming that

the corrosion protection of all ferrous materials shall be by means of Hot-dip Galvanizing, except

as otherwise permitted above.

1.12 NON CORRODING FASTENERS

Nuts, bolts, and washers shall be of non corroding metal or metal alloy.

Ferrous bolts, nuts and washers placed in outdoor positions shall be treated by hot dip

galvanizing to prevent corrosion, – except high tensile steel bolts and spring washers – which

shall be electro-galvanized to service condition four.

Appropriate precautions shall be taken to prevent electrolytic action between dissimilar

metals.

Where bolts are used on external horizontal surfaces and where water can collect, methods of

preventing the ingress of moisture to the threads shall be provided.

Taper washers shall be provided, where necessary, and protective washers of suitable

material shall be provided front and back on the securing screws.

All nuts and pins shall be adequately locked.

1.13 SAFETY

Registered Office: GUYANA POWER & LIGHT, Inc.,

49

40, Main Street, Cummingsburg, Georgetown, Guyana Telephone: 592-226-2600-9 Fax: 592-227-1978

ANNEX 257/259 Middle Street, Cummingsburg, Georgetown, Guyana

Telephone: 592-226-0565 / 66/68 Fax: 592-226-9821

Equipment shall not present Hazards to personnel involved in handling, installation, testing,

operation and maintenance.

1.14 HAZARDOUS SUBSTANCES

The Supplier shall give an assurance, in the following terms, that:

“There are no substances - in concentrations which could be classified as

hazardous under any applicable National, International or Other Codes or

Standards- in the Supply.”

In the event that hazardous substances are found in concentrations in breach of the above,

then:

The Supplier shall be responsible for any injury resulting from such hazardous

substances.

The Supplier shall accept responsibility for the return of the goods and disposal of the

hazardous substances.

There is an absolute prohibition on any PCB content whatsoever.

The Supplier shall submit safety data sheets for all substances in his Supply which could be

hazardous above certain limits.

1.15 SPARE PARTS

The Bidder shall give an assurance that spare parts, if required, will continue to be available

throughout the life of the equipment.

Spare parts shall be delivered suitably packed and clearly identified as to what they relate to

and, where applicable, with a designation number corresponding to a drawing or

corresponding to the spare parts list in the Operation and Maintenance instructions.

1.16 SPECIAL TOOLS

The Bidder shall provide a priced list of all special tools and apparatus required for erection,

commissioning and maintenance of the equipment.

1.17 PACKING SHIPPING AND DELIVERY

A. Delivery to a Designated Stores

Registered Office: GUYANA POWER & LIGHT, Inc.,

50

40, Main Street, Cummingsburg, Georgetown, Guyana Telephone: 592-226-2600-9 Fax: 592-227-1978

ANNEX 257/259 Middle Street, Cummingsburg, Georgetown, Guyana

Telephone: 592-226-0565 / 66/68 Fax: 592-226-9821

The Supplier shall ensure safe transit from the Manufacturer’s works to a Designated Store or

Warehouse and shall be responsible for all associated costs and expenses, including off-

loading, delivery, and insurance.

B. Customs Clearance and Delivery to Site

Customs Clearance and Delivery from such Designated Store or Warehouse to Site shall be

carried out by GPL at their expense.

C. Packing Cases

Packing Cases shall be robust, wooden and non-returnable packing. Equipment and

accessories shall be packed and securely clamped within such cases.

D. Delivery Documentation

Delivery Documentation shall include the following, at a minimum:

- a clearly defined delivery docket number

- supplier’s name;

- contract number / order no.

- quantity of material, description and GPL Item No.

- packing list

A packing list in a sealed waterproof envelope shall accompany each case/drum or other delivery

configuration.

Two copies of each packing list shall be sent to the Procuring Entity prior to dispatching the

equipment/material.

E. Marking of Packing Cases or Drums

Each packing case ( or drum – for cables and conductor ) shall be indelibly marked, on two sides

- with the following:

- individual serial number;

- Procuring Entity’s name;

- contract number / order no.

- supplier’s name;

- manufacturer’s name;

- country of origin;

- description of contents; or

- conductor/cable details and length on drum

Registered Office: GUYANA POWER & LIGHT, Inc.,

51

40, Main Street, Cummingsburg, Georgetown, Guyana Telephone: 592-226-2600-9 Fax: 592-227-1978

ANNEX 257/259 Middle Street, Cummingsburg, Georgetown, Guyana

Telephone: 592-226-0565 / 66/68 Fax: 592-226-9821

- case/drum measurements;

- gross and net weights; and

- all necessary slinging and stacking instructions.

F. Delivery Program

The Bidder shall state and guarantee a delivery time from the date of receipt of an official order

for the first consignment. He shall also clearly state the subsequent rate for dispatch of the

material on a per week/month basis.

1.18 LABELS

All apparatus shall be clearly labeled indicating where necessary, its purpose and service

positions

The material of all labels and plates their dimensions, legend and the method of printing shall be

subject to approval of the Procuring Entity.

Colors shall be permanent and free from fading. All labels and plates for outdoor use shall be

free of incorrodible material.

1.19 GUARANTEE

The Supplier shall provide a guarantee which shall include the following:

Satisfactory operation during the guarantee period of 18 months from the date of shipment.

Performance figures as supplied in the Technical Schedule.

No need for maintenance renewal of Corrosion Protection for at least five years from the

date of delivery.

1.20 SUBMITTALS WHICH SHALL FORM PART OF THE BID

The following Submittals, which shall form part of the Bid, shall be provided, in respect of

each item:

1. Schedules, duly completed:

- Technical Schedule

- Non-compliance Schedule

- Schedule of Type Tests Completed and Proposed Routine Tests.

There shall be attached to this Schedule:

Registered Office: GUYANA POWER & LIGHT, Inc.,

52

40, Main Street, Cummingsburg, Georgetown, Guyana Telephone: 592-226-2600-9 Fax: 592-227-1978

ANNEX 257/259 Middle Street, Cummingsburg, Georgetown, Guyana

Telephone: 592-226-0565 / 66/68 Fax: 592-226-9821

A. Copies of Type Test Certificates

B. Sample Copies of Routine Test Certificates

2. Delivery Program.

3. Descriptive Literature giving technical details

4. Outline Dimension Drawings.

5. Outline Installation, Operation and Maintenance Information

6. Manufacturer’s Recommendations regarding spares - together with prices.

A. Mandatory Spares

B. Recommended Spares

7. A Priced Schedule of all special tools and equipment required for erection,

commissioning and maintenance of the equipment.

8. Outline of Manufacturer’s Quality Assurance Policy/Program.

9. A Statement confirming that the corrosion protection of all ferrous materials not of

stainless steel shall be by means of Hot-dip Galvanizing, or alternative proposal as

indicated in Clause 1.06 B.

The Submittals, in total, shall provide all necessary detail to allow the offer to be evaluated

technically. Where applicable, detail required for life-span costing – e.g. Losses, etc – shall be

provided.

Data must be specific to the item offered. Generic or General Data is not acceptable.

Submittals, must be in English or with an English translation provided.

1.21 SUBMITTALS AFTER CONTRACT AWARD

A. Technical Folders – Hard Copy

The Procuring Entity shall nominate items of equipment for which the Supplier shall provide

two bound Folders of Technical Particulars.

Information in respect of each nominated item shall include the following, insofar as applicable:

- Descriptive literature giving full technical details.

- Detailed dimensioned drawings.

Registered Office: GUYANA POWER & LIGHT, Inc.,

53

40, Main Street, Cummingsburg, Georgetown, Guyana Telephone: 592-226-2600-9 Fax: 592-227-1978

ANNEX 257/259 Middle Street, Cummingsburg, Georgetown, Guyana

Telephone: 592-226-0565 / 66/68 Fax: 592-226-9821

- Installation, Commissioning and Operation and Maintenance Instructions

- Manufacturers Recommendations regarding spares

A. Mandatory Spares

B. Recommended Spares

- A Schedule of all special tools and equipment required for erection, commissioning

and maintenance of the equipment.

- Calculations validating the Design ( If requested by the Procuring Entity )

- Technical data schedule, with approved revisions

- Inspection and test reports carried out in the manufacturer’s works;

Such folders shall be subject to approval by the Procuring Entity, who shall reserve the right

to call for additional information, if in his opinion such is required.

B. Technical Folders – Electronic Version

Suppliers shall provide an Electronic Version of the Technical Folders in addition to the hard

copy.

C. Drawings and Documentation

1. Schedule for the Production of Drawings

Within 10 days of placement of order, the Supplier shall submit for approval by the

Procuring Entity, a schedule of the drawings to be produced. The schedule shall also

provide a program of drawing submittals.

2. Drawings and Document Formats

All detail drawings submitted for approval shall be to scale not less than 1:20. All the

important dimensions shall be given and the material of which each part is to be

constructed shall be indicated on the drawings. All documents and drawings shall

become the property of the Procuring Entity.

All drawings and calculations, submitted to the Procuring Entity, shall be on

international standard size paper, A0, A1, A2, A3 or A4. All such drawings and

calculations shall be provided with a contract title block, which shall include the name

of the Procuring Entity and shall be assigned a unique drawing number.

Lettering sizes and thickness of lettering and lines be selected so that if reduced by two

stages to one quarter of their size, the alphanumeric characters and lines are still

perfectly legible so as to enable them to be microfilmed.

Registered Office: GUYANA POWER & LIGHT, Inc.,

54

40, Main Street, Cummingsburg, Georgetown, Guyana Telephone: 592-226-2600-9 Fax: 592-227-1978

ANNEX 257/259 Middle Street, Cummingsburg, Georgetown, Guyana

Telephone: 592-226-0565 / 66/68 Fax: 592-226-9821

For presentation of design drawings and circuit documents, IEC Publication 617 or

equivalent standards for graphical symbols are to be followed.

3. Approval Procedures

The Supplier shall submit all drawings, documents and type test reports for approval in

sufficient time to permit modifications to be made if such are deemed necessary and re-

submit them for approval without delaying the initial deliveries or completion of the

supply. The Procuring Entity shall endeavor to return them within a period of

two weeks from the date of receipt.

Three copies of all drawings shall be submitted for approval and three copies for any

subsequent revision. The Procuring Entity reserves the right to request any further

additional information that may be considered necessary in order to fully review the

drawings. If the Procuring Entity is satisfied with the drawing, one copy will be

returned to the Supplier marked with “Approved” stamp. If the Procuring Entity is not

totally satisfied with the drawing, then “Approved Subject to Comment” status will be

given to it and a comment sheet will be sent to the Supplier. If the drawing submitted

does not comply with the requirements of the specification then it will be given “Not

Approved” status and a comment sheet will be sent to the Supplier. In both these cases

the Supplier will have to modify the drawing, update the revision column and resubmit

for final approval. Following approval, ten copies of the final drawings will be required

by the Procuring Entity.

Any drawing or document submitted for information only should be indicated as such

by the Supplier. Drawings and documents submitted for information only will not be

returned to the Supplier unless the Procuring Entity considers that such drawing needs

to be approved, in which case they will be returned suitably stamped with comments.

The Supplier shall be responsible for any discrepancies or errors in or omissions from

the drawings, whether such drawings have been approved or not by the Procuring

Entity. Approval given by the Procuring Entity to any drawing shall not relieve the

Supplier from his liability to complete the supply in accordance with this specification

and the conditions of contract nor exonerate him from any of his guarantees.

4. Electronic Versions of the Drawings & Documentation

Electronic versions of drawings and documentation shall be provided.

1.22 COMPLETENESS OF SUPPLY

All accessories or fittings not specifically mentioned in a Specification but which are

necessary or usual for similar equipment and for its efficient performance shall be

included in the Bid along with full details and price. The attention of the Procuring

Entity should be drawn to it.

Registered Office: GUYANA POWER & LIGHT, Inc.,

55

40, Main Street, Cummingsburg, Georgetown, Guyana Telephone: 592-226-2600-9 Fax: 592-227-1978

ANNEX 257/259 Middle Street, Cummingsburg, Georgetown, Guyana

Telephone: 592-226-0565 / 66/68 Fax: 592-226-9821

Appendix1

The following list includes but is not limited to the standards guiding the supplied equipment

specifications.

SECTION III GENERAL TECHNICAL REQUIREMENTS

1. Substation automation - IEC 61850.

2. Pipe labels –BS1710

3. "Hydraulic" nipples -BS 1486

4. Drawing- BS 308 and BS 1192, ISO 128, ISO 5455, ISO 5456, ISO 5457, ISO 6433, ISO

10209 and ISO 13567

5. Humid tropical conditions- ISO 12944

6. Nuts and bolts and washers- ASTM A396, IS0/R272 or BS 1802 and galvanized to

ASTM A153

7. Non-destructive examination of the finished weld -BS EN 1435 /BS EN 12517

8. Galvanized - ASTM A123, or BS 729

9. Nuts and bolts and small components shall be tested in accordance with ASTM A153 or

ISO 1459, 1460 and 1461

10. Chromium plating -BS 1224

11. Pressure gauges -BS EN 837

12. Thermometer pockets- BS 2765

13. Electrical instruments and meters -IEC 60051 and lEC 60521

14. Meters shall be calibrated -IEC 521

15. Panel wiring -BS 6231 Type A or B

16. Wire colours -British Standard 6746C

17. Motors -BS 4999, BS 5000 and IEC 60034

18. Main conductor and slot insulation- IEC 60085.

19. Terminals marked -BS 822

20. Contactors -IEC 60947-4-1

21. Current and voltage transformers -IEC 60044 and IEC60 185/ IEC 60186

22. Oil and compound -IEC 60296 or BS 1858

23. Cable boxes for transformers -BS 2562

24. Oil leakage routine test -BS 2562.

25. Compression glands -BS 6121

Registered Office: GUYANA POWER & LIGHT, Inc.,

56

40, Main Street, Cummingsburg, Georgetown, Guyana Telephone: 592-226-2600-9 Fax: 592-227-1978

ANNEX 257/259 Middle Street, Cummingsburg, Georgetown, Guyana

Telephone: 592-226-0565 / 66/68 Fax: 592-226-9821

SECTION VI OUTDOOR SWTCHGEAR AND EQUIPMENT

26. Clearances between live metal work and earth -BS7354

27. Circuit-breakers -IEC 60056 (BS 5311) and IEC 60298 and IEC 60694

28. Transient recovery voltages recorded during the tests- (BS 5311).

29. Tripping mechanism -IEC 60056-1

30. Tubular busbars and electrical connections in outdoor substations -BS. 159 and 1977

31. Porcelain and toughened glass insulators -IEC 60137 and IEC 60273

32. Suspension and tension insulators with ball and socket fittings -IEC 60120 and 372

33. Bushing insulators -IEC 60137

34. Isolating devices minimum safety clearances -BS 7354

35. Current transformers -IEC 60044

36. Voltage transformer accuracies and outputs- IEC 60186

37. Surge Arresters -IEC 60099-1

38. High current impulse test -IEC 600991

39. Whole of the rolled steel sections, tubes, flats, plates, bolts, buts and bars -BS EN 10113

SECTION VII METAL CLAD MEDIUM VOLTAGE SWITCHGEAR

40. Distance across all insulators -IEC 60056

41. Switchgear (indoor use) -IEC 60298

42. Air insulated switchgear -IP 2XC (IP 3X to IEC 60529)

43. Circuit-breakers -IEC 60056 and IEC 60298

44. Busbars and connections -BS 159

45. Cable boxes -BS 2562

46. Base & Floor -ASTM A-36

SECTION VIII PROTECTION METERING AND SCADA

47. Relays -IEC 60255, or equal, and IEC 61850

48. Relay cases -IEC 60068

SECTION IX BATTERIES, CHARGERS AND DC SWITCHBOARD

49. Batteries -IEC 60623

50. Radio frequency interference voltage -BS 800/ BS EN 55014.

SECTION X MAIN AND AUXILIARY POWER AND MULTICORE CONTROL CABLES

51. Cable outer coverings -BS 6746 or the relevant parts of IEC 60227 and IEC 60502.

52. Mechanical glands for the termination of electrometric or thermoplastic insulated cables -

BS.6121

Registered Office: GUYANA POWER & LIGHT, Inc.,

57

40, Main Street, Cummingsburg, Georgetown, Guyana Telephone: 592-226-2600-9 Fax: 592-227-1978

ANNEX 257/259 Middle Street, Cummingsburg, Georgetown, Guyana

Telephone: 592-226-0565 / 66/68 Fax: 592-226-9821

53. 69 kV cable shall be cross-linked applicable polyethylene insulated -IEC 60502 tested in

accordance with IEC 60840.

54. Conductors -IEC 60228 or BS 6360

55. Voltage Identification -BS 5467

56. Partial discharge test -Clause 3 IEC 60840

57. Conductor resistance measurement to Clause -14.2 IEC 60502.

58. Voltage test on outer-covering - Clause 3.1 IEC 60229.

59. High voltage test -clause 18 IEC 60502

60. Voltage (d.c.) test of 10 kV on anticorrosion covering -Clause 5 IEC 60229

61. Cables and associated terminating accessories type approval tests- IEC 60502

62. Insulating compounds -Clause 4 of IEC 502.

63. Core screen -IEC 60502

64. Multicore cables identified (red, yellow or blue)- IEC 60502

65. Anti-corrosion sheath extruded PVC compound to- IEC 60502

66. The armour bedding extruded PVC compound -BS 6346 IEC 60502

67. Armour on multicore cables -BS 1442 and BS 6346 or IEC 60502

68. Outer protective covering extruded black PVC compound -BS 6746

69. PVC insulated cable designs -BS 6346

70. XLPE insulated cables -BS 5467

71. Low Smoke & Fume cable - BS 6724.

72. Stranded copper conductors shall be un-tinned- BS 6360

73. Power type multicore control cables -BS 6346

74. Conductor insulation -BS 6234

75. All cable protective covers -BS 2484

76. Power cables flame retardant outer covering -IEC 331 and/or IEC 332

SECTION XI TRANSFORMERS

77. Transformers -IEC 60076 or ANSI C57 and NEMA TR-l.

78. On-load tap changers -IEC 60214 or ANSI C57

79. Rating plate data -IEC 60076 or ANSI C57.12.10

SECTION XII COMMUNICATION EQUIPMENT

80. Rating plate data -IEC 60076 or ANSI C57.12.10

81. Miniature circuit breakers -IEC 947-2

82. Printed Circuit Boards -BS 6221

83. PVC sheathed steel wire armoured and PVC served 600/1000 V grade -BS 6346

Registered Office: GUYANA POWER & LIGHT, Inc.,

58

40, Main Street, Cummingsburg, Georgetown, Guyana Telephone: 592-226-2600-9 Fax: 592-227-1978

ANNEX 257/259 Middle Street, Cummingsburg, Georgetown, Guyana

Telephone: 592-226-0565 / 66/68 Fax: 592-226-9821

84. Switchgear and isolators -BS 861

85. Batteries -IEC 623

86. Fuse links -BS 88 Class DC 40

SECTION XIII EARTHING ELECTRODES AND CONNECTIONS

87. Grounding -IEEE 80

88. Earthing conductors -BS 6480

SECTION XV LV SWITCHBOARD

89. LV Switchboards -IEC 947-1

90. 480V Switchboard -IEC 439

91. Moulded-case circuit breakers -IEC 947-2

92. Miniature circuit breakers -BS 3871

93. Fuses -IEC 269