release note spc42xx43xx52xx53xx63xx v3.2.2 en

23
s Building Technologies Division Technical Information Security Products SPC Series SPC42xx/43xx/52xx/53xx/63xx Firmware Release Note sBuilding Technologies Division: Security Products Page: 1 / 23 release_note_spc42xx43xx52xx53xx63xx_v3.2. 2_en.doc SPC42xx43xx52xx53xx63xx_V3.2.2 01.03.2012 Updates since: SPC42xx43xx52xx53xx63xx_V3.1.0 Feature type (related languages) CONTENT No storage of firmware on SPCX410 Fast Programmer .......................... 2 No direct upgrade possible for firmware versions 2.0.x or older .............. 2 SPC Pro (PC Programming Software) requirements ............................... 2 New Region option added for Spain........................................................ 2 New Fault Input types to handle Fault Conditions ................................... 2 New confirmation mode EN50131-9 added............................................. 2 New Menu Option “Failed to Set” added ................................................. 4 Viewing of Inhibited, Isolated Zones or Zones in Soak Test .................... 4 Multiple Input Activations are Logged 8 Times in a Set Period ................ 4 Various alterations for EN50131 compliance .......................................... 5 Antimask in Unset will now Cause Trouble by default ............................. 5 ZONE Masking Latched .......................................................................... 5 Change to Zone Attributes for Holdup and Tamper ................................. 5 Change to Operation of Line Fault Zone Type ........................................ 5 Selectable User Rights for Seismic Test ................................................. 5 Change to minimum timer for Strobe/Bells for Belgium ........................... 6 Zone Alerts Display Changed on Keypad................................................ 6 Random Test Call Times ........................................................................ 6 Added Access Events Reported over EDP or to SPC Pro....................... 7 EDP zone status expanded..................................................................... 7 Fast Format Low Battery Option ............................................................. 7 Change to CID code for hold up zone ..................................................... 7 Web Page Language not latched ............................................................ 7 Panel Doesn’t Send the Panel Unset Flag over EDP .............................. 7 X-Bus node reporting AC Power Failure over EDP ................................. 7 Fail to set not reported for CID ................................................................ 7 Modem Fault not reported over SIA or EDP ............................................ 7 No correct Toggling of test Channels of Redcare Modem ....................... 7 SMS Stops working after 5 Minutes of SMS messages........................... 8 No manual Test Call to ARC when selected from Keypad....................... 8 SPC Safe Reporting Timer not Working.................................................. 8 Time Locked Areas Not Unsetting........................................................... 8 Line fault zone type causing bells when full set....................................... 8 Unset with Card Reader not possible if Part Set ..................................... 8 Users reset changes Engineer PIN ......................................................... 8 Using pace did not update user language ............................................... 8

Upload: steven-hendrickx

Post on 13-Apr-2015

96 views

Category:

Documents


0 download

DESCRIPTION

Siemesns

TRANSCRIPT

Page 1: Release Note SPC42xx43xx52xx53xx63xx V3.2.2 En

s Building Technologies Division Technical Information Security Products

SPC Series SPC42xx/43xx/52xx/53xx/63xx Firmware Release Note

s Building Technologies Division: Security Products Page: 1 / 23 release_note_spc42xx43xx52xx53xx63xx_v3.2.

2_en.doc

SPC42xx43xx52xx53xx63xx_V3.2.2 01.03.2012 Updates since: SPC42xx43xx52xx53xx63xx_V3.1.0

Feature type (related languages)

CONTENT No storage of firmware on SPCX410 Fast Programmer .......................... 2 No direct upgrade possible for firmware versions 2.0.x or older .............. 2 SPC Pro (PC Programming Software) requirements ............................... 2 New Region option added for Spain........................................................ 2 New Fault Input types to handle Fault Conditions ................................... 2 New confirmation mode EN50131-9 added ............................................. 2 New Menu Option “Failed to Set” added ................................................. 4 Viewing of Inhibited, Isolated Zones or Zones in Soak Test .................... 4 Multiple Input Activations are Logged 8 Times in a Set Period ................ 4 Various alterations for EN50131 compliance .......................................... 5 Antimask in Unset will now Cause Trouble by default ............................. 5 ZONE Masking Latched .......................................................................... 5 Change to Zone Attributes for Holdup and Tamper ................................. 5 Change to Operation of Line Fault Zone Type ........................................ 5 Selectable User Rights for Seismic Test ................................................. 5 Change to minimum timer for Strobe/Bells for Belgium ........................... 6 Zone Alerts Display Changed on Keypad................................................ 6 Random Test Call Times ........................................................................ 6 Added Access Events Reported over EDP or to SPC Pro ....................... 7 EDP zone status expanded..................................................................... 7 Fast Format Low Battery Option ............................................................. 7 Change to CID code for hold up zone ..................................................... 7 Web Page Language not latched ............................................................ 7 Panel Doesn’t Send the Panel Unset Flag over EDP .............................. 7 X-Bus node reporting AC Power Failure over EDP ................................. 7 Fail to set not reported for CID ................................................................ 7 Modem Fault not reported over SIA or EDP ............................................ 7 No correct Toggling of test Channels of Redcare Modem ....................... 7 SMS Stops working after 5 Minutes of SMS messages ........................... 8 No manual Test Call to ARC when selected from Keypad....................... 8 SPC Safe Reporting Timer not Working .................................................. 8 Time Locked Areas Not Unsetting........................................................... 8 Line fault zone type causing bells when full set ....................................... 8 Unset with Card Reader not possible if Part Set ..................................... 8 Users reset changes Engineer PIN ......................................................... 8 Using pace did not update user language ............................................... 8

Page 2: Release Note SPC42xx43xx52xx53xx63xx V3.2.2 En

s Building Technologies Division: Security Products Page: 2 / 23 release_note_spc42xx43xx52xx53xx63xx_v3.2.2_en.doc

No storage of firmware on SPCX410 Fast Programmer IMPORTANT This firmware cannot be stored on SPCX410 Fast Programmer with 1 MB

memory due to file size. Download only via Web-Browser or SPC Pro.

No direct upgrade possible for firmware versions 2.0.x or older GENERAL The direct upgrade from firmware version 2.0.x (or older) to V3.x is not

possible. In this case it’s necessary to upgrade to V2.1.x first.

Note: The firmware can be found on product CD in the same folder as the V3.x firmware release.

Note: When upgrading older panels with new firmware not all new SPC features are supported (see release note for V3.1.0)

SPC Pro (PC Programming Software) requirements GENERAL This firmware is supported with SPCS310 SPC Pro release 3.2.0 or higher.

New Region option added for Spain NEW The Spanish Region can now be selected in order to comply with Spanish

standard requirements, in particular the alarm confirmation. ES

New Fault Input types to handle Fault Conditions NEW There are three new trouble types for detectors and signalling devices,

namely:

Detector Fault

Holdup Fault

Warning Fault

“Detector Fault” is a rename of the existing “Fault” input type. “Holdup Fault” and “Warning Fault” (an abbreviation for Warning Device Fault) are new input types.These new types will be available to all types of installations and all grades.

Reporting SIA CID

Open,

Disconnect, Short

Restore Open,

Disconnect, Short

Detector Fault BT BJ 380

Hold-up device Fault HT HJ 380

Warning Device Fault YA YH 380

All

New confirmation mode EN50131-9 added NEW The following new attributes have been added to system setting options:

New confirmation mode “EN50131-9” (in addition to GARDA and DD243) to enable alarm confirmation according to EN50131-9.

New option “Confirmation Zones” in order to define the number of zone activations for confirmed alarm when confirmation mode “EN50131-9” is selected.

All

Page 3: Release Note SPC42xx43xx52xx53xx63xx V3.2.2 En

s Building Technologies Division: Security Products Page: 3 / 23 release_note_spc42xx43xx52xx53xx63xx_v3.2.2_en.doc

Default operation of confirmation mode “EN50131-9”:

In order to be considered a confirmed alarm there must be three activations (resp. as configured with “Confirmation Zones”), these activations can be either an open or a tamper condition. Therefore a single zone may supply two activations to the confirmation. The following activations will cause a confirmed alarm (examples). - ZONE 1 alarm + ZONE 1 tamper + ZONE 2 alarm - ZONE 1 alarm + ZONE 2 alarm + ZONE 2 tamper - ZONE 1 alarm + ZONE 2 alarm + ZONE 3 alarm - ZONE 1 alarm + ZONE 2 alarm + ZONE 3 tamper - ZONE 1 tamper + ZONE 2 tamper + ZONE 3 alarm - ZONE 1 tamper + ZONE 2 tamper + ZONE 3 tamper - ZONE 1 alarm + ZONE 2 alarm + ZONE 3 tamper, The following activations will NOT cause a confirmed alarm (examples). - ZONE 1 alarm + ZONE 2 alarm + ZONE 1 alarm - ZONE 1 alarm + ZONE 1 alarm + ZONE 1 alarm

The alarm must be confirmed within 30 minutes in order to be considered a confirmed alarm. If an alarm is not confirmed within this 30 minute window, the zone will either be restored if it is closed or inhibited if it is open.

The activation of the following events (in addition to alarm and tamper) will also start a 30 minute timer and during this window any further alarm activations will be considered a confirmed alarm:

Modem fault

System tamper (e.g Bell tamper, Antenna tamper, Jamming, Cabinet tamper, Aux tamper, Aux 2 tamper, Xbus Tamper, Xbus communications)

In the case that the entry route zone has been inhibited a special entry procedure is enabled in order to prevent false alarms. The first alarm zone that is activated in the entry route is inhibited and this will start the entry timer.

Configuration:

Confirmation Mode “EN50131-9” can be selected in all Regions and all Grades.

If EN50131-9 is selected the “Confirmation Zones” can be changed from 2 to 10 (default = 3).

Exception for Spanish Region

For EN50131 grade 2: Three unique zones must be activated however the activation can be an alarm or tamper condition. The following activations will cause a confirmed alarm (examples). - ZONE 1 alarm + ZONE 2 alarm + ZONE 3 alarm - ZONE 1 alarm + ZONE 2 alarm + ZONE 3 tamper - ZONE 1 tamper + ZONE 2 tamper + ZONE 3 alarm - ZONE 1 tamper + ZONE 2 tamper + ZONE 3 tamper - ZONE 1 alarm + ZONE 2 alarm + ZONE 3 tamper,

Page 4: Release Note SPC42xx43xx52xx53xx63xx V3.2.2 En

s Building Technologies Division: Security Products Page: 4 / 23 release_note_spc42xx43xx52xx53xx63xx_v3.2.2_en.doc

The following activations will NOT cause a confirmed alarm (examples). - ZONE 1 alarm + ZONE 1 tamper + ZONE 2 alarm - ZONE 1 alarm + ZONE 2 alarm + ZONE 2 tamper - ZONE 1 alarm + ZONE 2 alarm + ZONE 1 alarm - ZONE 1 alarm + ZONE 1 alarm + ZONE 1 alarm

For EN50131 grade 3: There must be three activations from 2 detectors and these activations can be of any type. Therefore a single zone may contribute two open conditions to the confirmation however a second zone must supply another alarm condition in order to be considered confirmed. The following activations will cause a confirmed alarm (examples). - ZONE 1 alarm + ZONE 1 tamper + ZONE 2 alarm - ZONE 1 alarm + ZONE 2 alarm + ZONE 2 tamper - ZONE 1 alarm + ZONE 2 alarm + ZONE 3 alarm - ZONE 1 alarm + ZONE 2 alarm + ZONE 3 tamper - ZONE 1 tamper + ZONE 2 tamper + ZONE 3 alarm - ZONE 1 tamper + ZONE 2 tamper + ZONE 3 tamper - ZONE 1 alarm + ZONE 2 alarm + ZONE 3 tamper, - ZONE 1 alarm + ZONE 2 alarm + ZONE 1 alarm The following activations will NOT cause a confirmed alarm (examples). - ZONE 1 alarm + ZONE 1 alarm + ZONE 1 alarm

New Menu Option “Failed to Set” added NEW In system status, a new menu, called Fail to Set, will appear when an area

that keypad and user has access to, has failed to set. The menu will list all areas that have failed to set. When the area is selected, the reason will be displayed.

All

Viewing of Inhibited, Isolated Zones or Zones in Soak Test NEW Additional functionality has been added to the keypads for bypassing zones

so that when zones are bypassed, a user can press the up or down arrow to view the zones that have been bypassed. This functionality will also be available for soak test, inhibits and isolates.

A new keypad soak menu option has also been added to the system status menu for both user and engineer. This menu will allow a user to view any zones on soak, but will not allow the user to un-soak or isolate the zones.

All

Multiple Input Activations are Logged 8 Times in a Set Period CHANGE The limit for multiple activations on the same input during the same SET

period has been increased from one to eight. This means that if an input activates multiple times during the same SET period, the maximum number of times that it will be recorded in the LOG and reported to a central station will be eight.

Note: There has been no change to the fire input so this will still only be logged and reported once.

All

Page 5: Release Note SPC42xx43xx52xx53xx63xx V3.2.2 En

s Building Technologies Division: Security Products Page: 5 / 23 release_note_spc42xx43xx52xx53xx63xx_v3.2.2_en.doc

Various alterations for EN50131 compliance CHANGE There has been a review of alert operation in order to comply with

EN50131-3:2009. This will affect prevention of setting and warning device operation prevent.

All

Antimask in Unset will now Cause Trouble by default CHANGE The event “ZONE masked” in the unset state will produce a trouble event by

default to comply with the EN50131 standard.

New default settings are:

Ireland: Antimask in Unset Disabled Antimask in Set Alarm

All other countries: Antimask in Unset Trouble Antimask in Set Alarm

All

ZONE Masking Latched CHANGE The “ZONE Masked” event is now latched. This means that if a “ZONE

Masked” event occurs, it will remain active until restored by a level 2 user.

The operation of the ZONE Masked output has changed so that the output will remain active until restored.

ZONE Masking will be logged by default. The number of log entries will not exceed 8 between arming periods.

For an EN50131 Grade 3 system a ZONE masked event will prevent arming so a user must force set or clear the alert in order to set the system

Change to Zone Attributes for Holdup and Tamper CHANGE Change to zone attributes so that tamper and hold up zones can now be

inhibited. All

Change to Operation of Line Fault Zone Type CHANGE Change to operation of line fault zone type so now follows the fault type:

SIA reports Modem Fault + Zone number

CID reports Telco 1 Fault + Zone number

Outputs turns on fault output

Activates the fault led on keypad

Raises as info on keypad not alarm.

All

Selectable User Rights for Seismic Test CHANGE Before this version there was no user rights to allow a user to start a

Seismic test. A user right was implemented as follows:

User right is available for Standard User and Manager

For Manager the option is set by default, for standard user the option is not set by default

Only affects a MANUAL test (from keypad). Users without this attribute will still cause a seismic test to initiate when setting an area if that is how the panel is configured.

All

Page 6: Release Note SPC42xx43xx52xx53xx63xx V3.2.2 En

s Building Technologies Division: Security Products Page: 6 / 23 release_note_spc42xx43xx52xx53xx63xx_v3.2.2_en.doc

Change to minimum timer for Strobe/Bells for Belgium CHANGE When Region “Belgium” is selected the following default values have been

changed in accordance to Belgium TO-15 standard:

Default Minimum Maximum

Internal Bells

Grade= TO-14

0 min =infinite (old: 15 min)

0 min =infinite (old: 1 min)

999 min (old: 15 min)

Unrestricted 0 min =infinite (old: 15min)

0 min =infinite (no change)

999 min (no change)

External Bell Strobe

Grade= TO-14

0 min =infinite (old: 15 min)

0 min =infinite (old: 1 min)

999 min (old: 15 min)

Unrestricted 0 min = infinite (old: 15 min)

0 min =infinite (no change)

999 min (no change)

External Bells

Grade= TO-14

3 min (old: 15 min)

0 min = infinite (old: 1 min)

999 min (old: 15 min)

Unrestricted 3 min (old: 15 min)

0 min =infinite (no change)

999 min (no change)

BE

Zone Alerts Display Changed on Keypad CHANGE When there was a zone alert on the system which was subsequently

cleared, the user could see the fault LED flashing on the Keypad. However, the menu View Alerts would only show the zone description and so the user had no way of seeing what the problem was.

The user can now use a “Toggle” key (the ‘*’ key) to view the alarm condition in the View Alerts menu.

For Example, if a tamper occurred on “Hall ZONE”, then on entering the View Alerts menu, the user will see “Hall ZONE”. Upon pressing the ‘*’ key, the keypad will display “Zone 3 <T>”.

In General, the Zone <Alert Type> is one of the following:

Alarm = A

Tamper = T

Trouble = TR

Masked = M

Post alarm = PAX

All

Random Test Call Times CHANGE Change to the time that automated test calls and test SMS were being sent.

SMS tests will be transmitted between 9:00am and 6:00pm. ARC test calls will be transmitted between 1:00am and 5:00am.

Previously the automated test calls were always done at 2:00am which could lead to a resending of test calls when receiver was busy when many panels transmit test calls at the same time.

All

Page 7: Release Note SPC42xx43xx52xx53xx63xx V3.2.2 En

s Building Technologies Division: Security Products Page: 7 / 23 release_note_spc42xx43xx52xx53xx63xx_v3.2.2_en.doc

Added Access Events Reported over EDP or to SPC Pro CHANGE The following access events are now reported over EDP or to SPC Pro:

Card Format Invalid

Card is Void

Unknown Card

Incorrect Site Code

Clock and data reversed

All

EDP zone status expanded CHANGE A new element has been added to the zone status “LOGIC_INPUT”. This is

to address the issue of normally open zones reporting over EDP causing issues for external systems.

All

Fast Format Low Battery Option CHANGE Low Battery option has been added to ARC filter configuration for the Fast

Format page. All

Change to CID code for hold up zone CHANGE There has been a change to the CID code for hold up zone, the zone will

now transmit CID code “376” instead of “380. All

Web Page Language not latched CORRECTION No matter what language you select on the panel, the browser is always

English unless manually changed. Now the system language will be used by default.

All

Panel Doesn’t Send the Panel Unset Flag over EDP CORRECTION If the panel is unset after an alarm activation the panel would inform SPC

Com XT (or any EDP receiver) that it was part set and not unset.

The panel now correctly informs SPC Com XT (or any other EDP receiver) that the panel is unset.

All

X-Bus node reporting AC Power Failure over EDP CORRECTION X-Bus devices didn’t report node ID over EDP when AC power failed. This is

now corrected. All

Fail to set not reported for CID CORRECTION CID (contact ID) change that “Late to Set” and “Early to Set” will now use

CID codes 452 and 451. “Fail to set” will now be reported as 454. All

Modem Fault not reported over SIA or EDP CORRECTION The modem fault was not transmitted over SIA. The transmitted codes are:

Event: “YS” + modem number

Restore: “YK” + modem number

All

No correct Toggling of test Channels of Redcare Modem CORRECTION When testing an external Redcare modem the channels being tested were

not toggled correctly. This is now corrected. UK

Page 8: Release Note SPC42xx43xx52xx53xx63xx V3.2.2 En

s Building Technologies Division: Security Products Page: 8 / 23 release_note_spc42xx43xx52xx53xx63xx_v3.2.2_en.doc

SMS Stops working after 5 Minutes of SMS messages CORRECTION If the panel was send SMS messages for more than 5 minutes, SMS will no

longer work until the panel is power cycled. All

No manual Test Call to ARC when selected from Keypad CORRECTION Selecting test call in the keypad ARC menu would not make a test call. This

is now corrected. All

SPC Safe Reporting Timer not Working CORRECTION Automated Reporting after configuration change from the panel to SPC Safe

(Reporting Timer) was not working. All

Time Locked Areas Not Unsetting CORRECTION A bug has been fixed where if a Financial area was "TIME LOCKED" by

calendar and had "UNSET DELAY" enabled, the area would not unset after the calendar unset timer started, the area remained Fullset.

All

Line fault zone type causing bells when full set CORRECTION The line fault zone type has changed so that when Fullset it will no longer

activate bells and will now only activate the buzzer on the keypads when unset.

All

Unset with Card Reader not possible if Part Set CORRECTION It was not possible to unset an area from a card reader (connected to 2-door

expander) if an area was part set. This is now corrected. All

Users reset changes Engineer PIN CORRECTION If users had 6 or more digits in their PIN’s and used the “reset all users”

utility, the Engineer PIN defaulted to 000585. The Engineer PIN is now correctly reset to default 001111.

All

Using pace did not update user language CORRECTION When using Pace the user language was set to the system language and

not to the user language. This has been corrected All

END

Page 9: Release Note SPC42xx43xx52xx53xx63xx V3.2.2 En

s Building Technologies Division: Security Products Page: 9 / 23 release_note_spc42xx43xx52xx53xx63xx_v3.2.2_en.doc

SPC42xx43xx52xx53xx63xx_V3.1.0 06.09.2011 Updates since: SPC42xx43xx52xx53xx63xx_V2.1.3

Feature type (related languages)

No storage of firmware on SPCX410 Fast Programmer IMPORTANT This firmware cannot be stored on SPCX410 Fast Programmer with 1 MB

memory due to file size. Download only via Web-Browser or SPC Pro.

No direct upgrade possible for firmware versions 2.0.x or older GENERAL The direct upgrade from firmware version 2.0.x (or older) to V3.x is not

possible. In this case it’s necessary to upgrade to V2.1.x first.

Note: The firmware can be to be found on product CD in the same folder as the V3.x firmware release. When upgrading older panels with new firmware not all new SPC features are supported (details see further below).

SPC Pro (PC Programming Software) requirements GENERAL This firmware is supported with SPCS310 SPC Pro release 3.1.0 or higher.

Default PIN’s / Change Number of digits in PIN GENERAL Following rule is strictly applied across the system.

Default Engineer PIN is 1111 for 4-digit PIN (e.g in EN50131 Grade 2 systems).

Increasing the number of digits will add the relevant number of zeros to the front of an existing Engineer / User PIN. As an example, Default Engineer PIN is 01111 for 5-digit PIN (e.g in EN50131 Grade 3 systems).

Supported languages NEW Supported languages in this release are English (en), German (de), Italian

(it), Spanish (es), Swedish (sv), Dutch (nl), Flemish (vls), French (fr) en, de, es, it, sv, nl, vls, fr

Import of external language file NEW New options have been added to support import of an external language file

via Web Browser and Fast Programmer. The imported language can be used in the same way as the core languages available on the panel.

WEB browser: New File option “Import Language File” to make the language available for WEB browser and Keypads.

Fast Programmer: New option in Keypad Engineer menu.

Note: The system supports language files with ISO code page 1250/1252.

All

Individual assignment of language to a user NEW New options have been added to support individual use of languages in the

panel for multi-lingual applications. Previously it was only possible to apply the same language to all system users.

Existing Language option "Language" to define system default language.

New Language attribute "Idle Language" to display preferred language in idle state (options “Use system language” or “last used”)

New System Timer "Keypad Language"(0-9999 seconds) to define

All

Page 10: Release Note SPC42xx43xx52xx53xx63xx V3.2.2 En

s Building Technologies Division: Security Products Page: 10 / 23 release_note_spc42xx43xx52xx53xx63xx_v3.2.2_en.doc

waiting time in idle state before switching back to system default language.

New User attribute “Language” to select language which is applied to this user.

Note: For Engineer access the default language will be applied.

New Financial function NEW The installation type “Financial” has been added to the area options for easy

configuration of typical applications used in financial segment.

When this option is selected new configuration options are added to the system:

New Area option "Area Type" to select area types "Standard", "ATM", "Vault" and "Advanced" to support typical use cases in financial segment with predefined area settings and timing functions.

Depending on chosen financial area type, following new options are available:

New Area timer "Delay Unset" (0-120 minutes) to delay unset (e.g. of an ATM).

New User Right “Bypass Delayed Unset” to enable user to bypass “Delayed Unset” timer (e.g. for Cash in Transit users).

New Area attribute "Interlock Group" (1-8) to enable only one area of this group to be unset (e.g. only one ATM is unset).

New Area attribute "Time Locked" to lock Vault with a calendar

New Area timer "Vault Access" (0-120 min) to enable Vault access only for a limited time after time locked unset.

New Zone type and output type “Seismic” to support seismic detector testing (see separate feature description)

IMPORTANT: Not all SPC panel types support the financial features. Please refer to the according datasheet of the specific panel type if financial features can be supported. IMPORTANT: KNOWN BUG: Following bug is known and will be corrected in one of the next releases:

When a Financial area is "TIME LOCKED" by a calendar and "DELAY UNSET" timer is configured, the area will not unset after the calendar unset timer starts (resp. remains fullset).

All

Digital Audio / Video alarm verification NEW Audio trails and video images from pre-, post- and live-events can be sent

via IP (over Ethernet) to CMS/ARC using the EDP protocol. This allows the CMS operator to verify and confirm an alarm in less time with a high true alarm rate.

Additional options have been added to Web Browser to support the verification feature via IP (over Ethernet).

New Verification option "Verification Zones" to create and configure verification zones. Maximum 1 audio device (SPCV320/321 Audio Expander or SPCK623 Comfort Keypad with Audio) and/or 1 IP-

All

Page 11: Release Note SPC42xx43xx52xx53xx63xx V3.2.2 En

s Building Technologies Division: Security Products Page: 11 / 23 release_note_spc42xx43xx52xx53xx63xx_v3.2.2_en.doc

camera can be configured per verification zone. Maximum system capacity: SPC43xx: Max. 4 verification zones / 4 cameras / 4 audio devices SPC53xx: Max. 8 verification zones / 4 cameras / 8 audio devices SPC63xx: Max. 16 verification zones / 4 cameras / 16 audio devices

New Zone option "Verification Zone" to configure the verification zone to be activated when input is triggered (supported zone types: "Alarm", "Entry-Exit", "Fire Exit", "Panic", "Hold-up" and "Seismic") Note: The verification event on “Entry-Exit” is triggered when the entry route starts.

New Verification options “Camera” to configure camera settings: - IP-settings to connect to camera in same subnet. - Pre-defined settings for the Siemens cameras CCIC1410 and CFMC1315. - Configurable CGI command string to capture picture from generic cameras. - Up to 16 pre / 16 post event images (by JPEG resolution 320 x 240, max. 1 frame / sec.) per IP-camera.

New Verification options “Verification” to configure audio settings: - Up to 60 sec. pre / 60 sec. post audio recording per audio device

New System Option "Silence during Audio Verification" to switch off external bells, keypad buzzers and annunciation messages in case of post- and live event recording.

New System Option "Audio Expander LED" to switch off LED on Audio Expander. LED of satellite (WAC11, WAS11) need to be configured with jumpers.

Separate transmission of pre-/post events to provide operator already the pre-event information when post-event is still running.

New User Right "View Video" to allow user to watch live pictures of all cameras via WEB interface

New EDP receiver setting option “Live Streaming” to select privacy options for live streaming (Disabled / Only after Alarm event / Always).

New EDP receiver setting option “Verification” to enable transmission of verification data to receiver.

IMPORTANT: Limitations when using IP over GPRS The performance and feature set is limited when IP over GPRS is used as backup channel for verification. To activate GPRS channel the Ethernet connection must be down or disabled and the GPRS connection to EDP receiver has to be established and the GPRS IP address must be known to the EDP receiver (e.g. SPC Com XT).

The pre / post event audio files and pictures can be retrieved via GPRS. The limited bandwidth of GPRS transmission must be taken into consideration (it may take up to several minutes to transmit pre event files).

Live audio / Video over GPRS is not supported due to limited GPRS bandwidth.

Seismic Detector Test (automatic / manual) NEW

Page 12: Release Note SPC42xx43xx52xx53xx63xx V3.2.2 En

s Building Technologies Division: Security Products Page: 12 / 23 release_note_spc42xx43xx52xx53xx63xx_v3.2.2_en.doc

New options have been added to support testing of seismic detectors.

Automatic seismic detector testing features:

New Zone type "Seismic" to connect Seismic detectors.

New Zone attribute "Automatic Sensor Test" for seismic detectors to include in manual or automatic seismic detector test.

New Output type "Seismic Detector Test" to activate test vibrator of seismic detectors within an area.

New System Timer "Seismic Sensor Auto test" (12-240 hrs) to define average time between random tests.

New System Timer "Seismic Sensor Test Duration" (3-120 sec) to define max. waiting time for sensor after activation of test vibrator.

New System Option "Seismic Test on Manual Set" to enable seismic sensor test before setting an area with seismic detectors.

If area is set automatically (by calendar, key switch or input) or remotely (e.g. via EDP by SPC Com) the automatic test before setting will be skipped (only random automatic testing will be performed.

If automatic seismic test fails a ‘Trouble’ is reported: SIA: UT/UR (untyped trouble), CID: 150 (non burglary)

Manual seismic detector testing features:

A manual seismic test can only be triggered by the Engineer and User by the Keypad. A manual test is selected by Area and will test all seismic sensors in that area at the same time.

All seismic sensors that fail are reported in the keypad.

If a manual seismic test fails, no events are reported (only local message on keypad).

IMPORTANT: Not all SPC panel types support the financial features. Please refer to the according datasheet of the specific panel type if financial features can be supported.

All

Temporary unset of areas NEW A new Area attribute "Unset duration" has been added to limit time (0-120

minutes) an area can be unset (e.g. an ATM).

All

Reporting of Early/Late to Set/Unset of areas NEW New attributes and timers for "Early to set”, “Early to Unset”, “Late to set”

and “Late to unset” have been added to the area options. This enables a report to be sent to CMS/ARC if the panel is manually Fullset/Unset before/after a scheduled Set/Unset and before/after the number of minutes (0-120 minutes) entered in the Timer field.

All

Enhanced area auto-set options NEW Additional options have been added respectively re-arranged in area

settings for enhanced auto setting options. These options can be combined All

Page 13: Release Note SPC42xx43xx52xx53xx63xx V3.2.2 En

s Building Technologies Division: Security Products Page: 13 / 23 release_note_spc42xx43xx52xx53xx63xx_v3.2.2_en.doc

with the financial functions.

Area attribute “Auto Set Warning Time” to define warning time 0 – 30 minutes before auto set. Note: The panel sets either at the scheduled time or at the time defined by the “Delay Unset” parameter. The first warning is displayed at the configured time before the scheduled time.

New Area attribute “Auto Set Delay” to enable a user with enabled user right “Delay Auto Set” to delay Auto Setting for this area.

New Area attribute “Auto Set Cancel” to enable a user with given user right “Auto Set Delay” to cancel Auto Setting for this area.

New Area attribute “Key Switch” to enable a user to delay auto setting via key switch expander (SPCE110) by the time defined in “Delay Interval”.

New Area timer “Delay Interval” to define the time [1-300 minutes] the auto setting can be delayed at once.

New Area attribute “Delay Counter” to define the number of times [1-99, 0=unlimited] the auto setting can be delayed by the “Delay Interval”.

New System Option “Output Configuration” to configure behavior for “Auto Set” output (SPC Pro: To be found under Advanced options in Advanced Output Options):

New Output Configuration option "On" to permanently activate Auto Set output during warning time.

New Output Configuration option "Keypad" to follow keypad beep pattern.

New Output Configuration option "Progressive" to increase warning indication frequency during warning time before setting: - 20 Minutes before set: Buzzer will be activated every 30 Seconds. - 10 Minutes before set: Buzzer will be activated every 15 Seconds. - 3 Minutes before set. Buzzer will be activated every 5 Seconds If option is disabled the buzzer will be activate every minute (except last minute it’s every 10 seconds).

New Output Configuration option "Pulse Time" (n x 100ms) to define the time the Auto Set output is active when pulsed.

“All Okay” entry procedure NEW New options have been added to support “All OK” entry procedure. This is

to enable the first employee in the morning to check the premises for any suspicious indications and inform the next employees about the result with visual indication.

New Area option “All OK required” to enable “All OK” entry procedure.

New Area timer "All Okay Verification Time (1-999 sec) to define the maximum time window until the "All Okay" button has to be pressed.

New Zone type "All Okay" to be activated from first user (e.g. hidden

All

Page 14: Release Note SPC42xx43xx52xx53xx63xx V3.2.2 En

s Building Technologies Division: Security Products Page: 14 / 23 release_note_spc42xx43xx52xx53xx63xx_v3.2.2_en.doc

push button) before “All OK Verification Time” expires.

New Area attribute "All Okay event" to define the alarm type if "All Okay" entry procedure was not successfully terminated.

New Output types "Entry Status" and "Warning Status" to indicate status (e.g. via LEDs) to other users after first user has entered the premises.

IMPORTANT: This feature shall only be used for areas which are ALWAYS manually unset (unset by calendar or remotely will also require ALL OK button pressed).

Additional linking options for areas NEW Additional options have been added to the area settings to prevent setting /

unsetting of linked areas:

Prevent Fullset: Prevent this area from Fullset if any linked area is not Fullset

Prevent Fullset All: Prevent linked areas from Fullset if this area is not Fullset.

Prevent Unset: Prevent this area from Unset if any linked area is Fullset

Prevent Unset All Prevent linked areas from Unset if this area is Fullset.

All

Dual PIN for Set/Unset NEW New Area attribute “Dual PIN” has been added. If this option is enabled, two

PIN’s are required to Set or Unset the area with the keypad. Both PIN’s must belong to users who have the required user right for the operation (Setting or Unsetting). If the second PIN is not entered within 30 seconds, or it is wrong, then the area cannot be Set or Unset.

All

Exit Route through Multiple Areas NEW New Keypad attribute “Delay Fullset” has been added. If enabled, the exit

timers are used across all areas the keypad is assigned to respectively the user has the user rights for.

Previously (or if attribute is disabled) only the entry/exit timer of the particular area is running in which the keypad is located.

All

Door Interlock to prevent other doors from opening NEW New Door attribute “Interlock” has been added. This prevents remaining

doors from opening if one of the doors in the same Door Group is already open (e.g. people separation entries in banks).

All

Reader locking after PIN / Card Tamper CHANGE When presenting of an invalid card or three invalid PIN’s a PIN tamper on a

reader will be generated and causes that reader to be locked out for 2 minutes. This is only if PIN or card are invalid and not if they don’t have access.

All

Set / Unset with Prefix for Card Readers with PIN pad NEW

Page 15: Release Note SPC42xx43xx52xx53xx63xx V3.2.2 En

s Building Technologies Division: Security Products Page: 15 / 23 release_note_spc42xx43xx52xx53xx63xx_v3.2.2_en.doc

A new Door attribute “Setting Prefix” has been added to set/unset an area with a card reader using a prefix ‘*’ resp. ‘A’ or ‘#’ resp. ’B’. If enabled the area will be set (if reader is enabled and user rights are given) when keys ‘*’/‘A’ or ‘#’/’B’ are pressed before showing the card. This will work on readers with PIN pads which send a 10 for ‘*’/’A’ and 11 for ‘#’/B (e.g.Siemens PP500). Previously the set/unset of an area with a reader was only possible by presenting the card twice within a few seconds (double batching).

Note: Using “Setting Prefix” is superseding the double batching procedure to set/unset an area.

All

Different door modes depending on area setting state NEW New options have been added to change security level an area can be

accessed via door reader depending on the setting state of the area. E.g. during day (normally the area is unset) the users can present the card to open the door, but during night (area is set) the door requires Card + Pin to unset area / to open the door.

New System Options "Door Mode Set" and "Door Mode Unset" to define security level to open the door. - Default: Will act as defined at individual doors - Card + PIN: Will require Card + Pin - Card or Pin: Will require Card or Pin Note: The Card + PIN " or " Card or PIN " are superseding system wide the individual door setting options "Card + PIN", "Pin only", "PIN or Card", "Pin to Exit", if area is set resp. unset.

New system option "Override Reader Profile" to indicate required actions from or confirmations to the user via the reader LED’s: - No LED indication in idle state (independent if area is set or unset) - Fast flashing green LED when system expects the 2nd identification - If the user tries to set via reader the RED Led is permanently on for 10 sec. if area could be successfully set resp. RED Led is flashing for 10sec. if area could not be set for any reason. Note: This setting supersedes individual door setting options “LED Reader Profiles”. The status indication is optimized for readers with 2 individually controllable LED’s (e.g. Siemens PP500).

All

Additional Card Reader Profiles for HID Readers NEW Additional Card Reader profiles “Profile 3 [PIN/Site 0]” and “Profile 4

[PIN/Site 0]” have been added to the door expander options. This is to support the PIN pad option of HID readers that send the PIN to the panel as a special card read with predefined site code.

Note: To support this feature the 2-door expander in SPCA210, SPCP432 or SPCP433 requires firmware version 1.6 or higher

All

New Zone attributes “Unset Local” and “Silent” NEW New Zone attributes have been added to the zone options:

Unset Local: When this attribute is set, an alarm generated by the zone opening when the area is Fullset or Partset will be reported in

All

Page 16: Release Note SPC42xx43xx52xx53xx63xx V3.2.2 En

s Building Technologies Division: Security Products Page: 16 / 23 release_note_spc42xx43xx52xx53xx63xx_v3.2.2_en.doc

the usual way. However, if the area is unset there will be only a local alarm i.e. keypad buzzer, LED flash and zone display. This attribute is only applicable to Alarm, Fire and Seismic zones.

If the ‘Silent’ attribute is set then there will be no audible or visual indications of the Alarm. The alarm activation will be sent to the Receiver station. If the system is unset then a warning message is shown on the display.

New options for “Keyarm” zone type NEW New Zone attributes have been added to the “Keyarm” zone type:

Open Only: If this attribute is set then the setting state of the area will toggle every time this zone is activated. If this attribute is disabled the area will set when zone is activated and unset when zone is deactivated.

Fullset Enable: If this attribute is set then zone activation will only Fullset the system/area. Unset will not be possible. This is used if the user should have the ability to only FULLSET the system from a Keyarm zone and the unsetting of an area shall be prevented from a key arm zone.

Unset Enable: If set then zone activation will only Unset the system/area. Fullset will not be possible. This is used if the user should have the ability to only UNSET the system from a Keyarm zone and the setting of area shall be prevented from a Keyarm zone.

All

New Output types for system supervision NEW New Output types have been added to signal additional system status:

“Modem 1 Line Fault”: This output activates when there is a line fault on the primary modem.

“Modem 1 Failure”: This output activates when the primary modem fails.

“Modem 2 Line Fault”: This output activates when there is a line fault on the secondary modem.

“Modem 2 Failure”: This output activates when the secondary modem fails.

“Battery Low”: This output activates when the battery is low.

All

Strobe infinite time CHANGE New value “0” allowed in System Timer option “External Bell Strobe” to

activate strobe permanently. Previously the strobe could only be activated during a finite time window.

All

New output type “Local Alarm” NEW A new Output type “Local Alarm” has been added to the output options. This

output activates on a local intrusion alarm of zone types “Alarm”, “Entry/Exit” and “Seismic” until the a transmission takes place (if no transmission takes place the output remains on until alarm restore).

All

Configuration of “Latch Output” NEW

Page 17: Release Note SPC42xx43xx52xx53xx63xx V3.2.2 En

s Building Technologies Division: Security Products Page: 17 / 23 release_note_spc42xx43xx52xx53xx63xx_v3.2.2_en.doc

New System Option “Output Configuration” (SPC Pro: To be found under Advanced options in Advanced Output Options) to adapt behavior of the “Latch” output (used to reset latching sensors as smoke or inertia detectors) to various scenarios (multiple selections possible):

New Output Configuration option "Entry Time" to turn “Latch” output on at end of exit time and off at beginning of entry time.

New Output Configuration option "Fire Exit" to turn “Latch” output on if any Fire X zones are active.

New Output Configuration option "Unset" to turn “Latch” output on if user Unsets systems, momentary.

New Output Configuration option "Alarm Reset” to turn “Latch” output on when an alarm is reset , momentary

New Output Configuration option "Resetting Alarm” to turn “Latch” output on during setting procedure if glass-break /smoke detectors are open and not in alarm.

New Output Configuration option "Engineer Exit" to turn “Latch” output when engineer leaves engineer mode, momentary.

All

Configurable Antimask behaviour NEW New System Options have been added to select the event type reported

resulting from antimask detection depending on area setting state.

"Antimask Set": Select reported event type if area is set (alarm, tamper, trouble, disabled).

"Antimask Unset": Select reported event type if area is unset (alarm, tamper, trouble, disabled).

Note: The option can only be configured when the panel is in ‘Unrestricted’ mode. In Grade 2 or 3 mode, the type of event reported is in accordance with the standards for the selected region:

Ireland: Alarm on Set / Disabled on Unset

All other regions: Alarm on Set / Tamper on Unset

All

Wireless Timers moved CHANGE Setting options for two wireless timers (“Device Lost” and “Prevent Setting”)

was moved from the System Timer options to the Wireless Setting options.

All

New Cause & Effect area triggers “Delay Auto Set” and “Clear Alarms” NEW Additional Area trigger options have been added to the area option.

“Delay Autoset”: The automatic setting of an area can be delayed by the “Delay Interval” time with a Cause&Effect trigger.

“Clear Alarm”: The alarms of an area can be restored with a Cause&Effect trigger.

All

WPA (Wireless Panic Alarm) support NEW The IPAW8-10 provides additional security and comfort functions to people

carrying the Wireless Panic Alarm.

The number of WPA’s (IPAW8-10) which can be addressed depends on

All

Page 18: Release Note SPC42xx43xx52xx53xx63xx V3.2.2 En

s Building Technologies Division: Security Products Page: 18 / 23 release_note_spc42xx43xx52xx53xx63xx_v3.2.2_en.doc

panel type:

SPC4xxx: max. 32 WPA’s

SPC5xxx: max. 128 WPA’s

SPC6xxx: max. 128 WPA’s

New options have been added to support the WPA device IPAW8-10.

New Wireless section "WPA" to configure the IPAW8-10.

New WPA attribute "Function Buttons” to define function per button (red, green, yellow) and the combination of it. Configurable functions are Panic, Holdup, Suspicion, RF Output.

New Trigger options "WPA Function" to use pressing of WPA button (or a combination of it) as a trigger for Cause & Effect.

New WPA attribute "Transmitter ID" as unique reference for a specific WPA (printed on IPAW8 -10 housing) to address the device to the system without learning it in via keypad.

New WPA attribute "Supervise" to enable supervision of device from panel (IPAW8-10 must be enabled to transmit supervision signals).

New WPA attribute "Test" to enable test function.

New Wireless timer option "WPA Test Schedule" (0-365 days) to define number of days between tests.

New User Right "WPA test" to enable user to perform a WPA test anytime to check correct functioning of the device. All three buttons on WPA have to be pressed simultaneously.

Note:

The IPAW8-10 is compatible to following SiWay receivers: - SPCW111/112 with revision 5.0 or higher - SPCW110 with revision 5.0 or higher - SPCW130 with revision 5.0 or higher

The IPAW8-10 is not supported via SPCK422

Firmware of wireless receivers (SPCW110 / SPCW111 / SPCW112 / SPCW130) cannot be upgraded.

RF unset during Entry time NEW New Area option “FOB Unset Entry” has been added. If enabled, unset of

area with wireless remote control (FOB) is only allowed when entry timer is running. If disabled the area can anytime be unset.

All

Dedicated RF Outputs NEW New options have been added to control a dedicated output by a wireless

remote control without using cause & effect programming.

New Output type "RF Output" to be activated by RF remote control.

New User Right "RF Control" to allow user to control RF outputs

New Area attribute "RF Output Time" (seconds) to define how long "RF Output" is activated (0=toggle).

All

Page 19: Release Note SPC42xx43xx52xx53xx63xx V3.2.2 En

s Building Technologies Division: Security Products Page: 19 / 23 release_note_spc42xx43xx52xx53xx63xx_v3.2.2_en.doc

Activate Mapping Gate output by user NEW New options have been added to enable a user to switch on/off mapping

gate outputs via WEB browser.

New User Right “MG output control”: If enabled, the end user is allowed to switch unprotected mapping gates when logged on to the Web Server.

New Mapping Gate option “Protected” in Mapping Gate options: If enabled, the user CANNOT switch this mapping gate, even if the user right is given to do so.

All

Alarm Abort Transmission after valid PIN NEW New system timer “Alarm Abort” has been added. This defines the time

window (0 – 999 seconds) after a reported alarm in which an alarm abort message can be reported after valid user PIN is entered.

All

Restore state after power down CHANGE Added support for storing state variables in flash, to allow panel to restore

its state after a complete power down.

All

Additional SMS event transmission / Time Stamp NEW New functions have been added for SMS transmission:

The attribute “Others” has been added to transmit the remaining events (System Restart, User PIN Tamper, Time Change, Full Engineer Mode enabled/disabled) which cannot be selected by other SMS event filters.

Time stamp of event is also transmitted. Previously no time stamp was transmitted with the event.

All

Automatic Padding of Contact ID account numbers CHANGE The Contact ID account numbers are automatically padded :

If number is less than 4 digits it will be padded to 4 digits

If number is greater than 4 digits it will be padded to 6 digits

Previously the Contact ID account numbers were not automatically padded.

All

SIA Code “ZS” and “UA” changed to “ZX” and “UT” CHANGE SIA code ZX is used instead of ZS for zone short, as ZS was already

defined in the SIA standard for another purpose. This applies only to EDP.

SIA code UT is used instead of UA for Trouble messages.

All

Extended event filter settings NEW Additional event filters options have been added to the event filter options:

For CID, SIA and EDP protocol:

Early/Late: If enabled, early and late openings and closings of areas (as defined in area options) are reported.

Alarm Abort: If enabled, alarm abort messages are reported.

All

Page 20: Release Note SPC42xx43xx52xx53xx63xx V3.2.2 En

s Building Technologies Division: Security Products Page: 20 / 23 release_note_spc42xx43xx52xx53xx63xx_v3.2.2_en.doc

For EDP protocol:

Zone States: If enabled, all zone input state changes are reported independent of area setting state.

Network: IP Network Polling Up/Down events are reported.

Others (non standard): Non supported SIA codes used with SPC COM XT including Camera Online/Offline events are reported (CU: Camera online / CV: Camera offline).

Other EDP Protocol enhancements NEW The EDP protocol has been enhanced in particular aspects to support

additional market needs. Overview:

Support of audio / video verification features through EDP

Time stamp of panel added to reported events.

Reporting of physical zone states

Reading Access Log

Support of TCP/IP: New option “Network Protocol” in EDP receiver settings in WEB interface to configure UDP or TCP connection to receiver. Previously only UDP was supported. Note: This feature is only supported with SPCN310 GSM module with “Wismo” GSM chip fulfilling all the characteristics below: - Wismo chip fitted (visible on PCB), - PCB Revision E-PC142011 IE; Rev 1.1 PCB - Hardware Build Revision (seen on packaging label): A - Hardware Revision (seen on user Interface): 2 (Note: Rev 1.x with Enfora GSM Chip don’t support this feature) - Firmware Release: V3.x

Full EDP protocol description is available on request from product management.

All

EDP receivers as poll master must send poll message first CHANGE After a communication channel is opened by the EDP receiver, the poll

master must send a poll message before any other message. With version 2.2.x and lower it was not necessary to send a poll message to get a response from the SPC control panel.

All

Limited time synchronization request via EDP NEW New System Timer “Time Sync Limit” has been added. If this option is

enabled a time synchronization command via EDP is only accepted by the panel if the new time and actual time of control panel are outside of the defined time window (0-999 seconds). Otherwise, the command will be ignored without any time correction, confirmation message or log entry. Previously all time set commands coming via EDP have been accepted by the panel.

All

Separate firmware file for peripherals / upgrade of modems NEW The firmware of panel and peripherals (expanders, keypads, door

controllers and modems) are delivered as separate files with extension “.fw” for panel and “.pfw” for peripherals (tb found on product CD in the same

All

Page 21: Release Note SPC42xx43xx52xx53xx63xx V3.2.2 En

s Building Technologies Division: Security Products Page: 21 / 23 release_note_spc42xx43xx52xx53xx63xx_v3.2.2_en.doc

folder as panel firmware)

It’s now possible to upgrade also firmware of GSM and PSTN modems. This feature is supported for following modems:

SPCN310 with “Wismo” GSM chip: Upgradable modems have to fulfill all of the characteristics below: - Wismo chip fitted (visible on PCB), - PCB Revision E-PC142011 IE; Rev 1.1 PCB - Hardware Build Revision (seen on packaging label): A - Hardware Revision (seen on user Interface): 2 (Note: Rev 1.x with Enfora GSM Chip cannot be upgraded) - Firmware Release: V3.x

SPCN110: Upgradable modems have to fulfill all of the characteristics below: - PCB Revision E-PC137421 IE; Rev. 2.1 PCB, and - Hardware Build Revision (seen on packaging Label): A1 - Hardware Revision (seen on user Interface): 1 - Firmware Release 2.x

Previously the firmware of peripherals and panel was packed in the same file. Update of GSM / PSTN modules was not possible.

Note: Firmware of wireless receiver modules (SPCW110 / SPCW111 / SPCW112 / SPCW130 cannot be upgraded.

Engineer Exit NEW A new System Option “Engineer Exit” has been added. If enabled the

Engineer can exit from Full Engineer even if faults are present. The Previously it was not possible to leave the Full Engineer mode without isolating or repairing the faults.

All

View Alerts without clearing NEW New Keypad Menu option “View Alerts” have been added to allow users

(standard or manager) to view alerts without clearing them. All

Key switch Function NEW The programming options for Key Switch Expander SPCE110 have been

extended with programmable functions for each key switch position to align with Indication Expander SPCE120. Previously it was only possible to use key switch positions as trigger input for cause & effects.

All

Retriggering of Panic and Duress alarms NEW New System Options have been added to retrigger Duress and Panic

alarms without restoring the alarm. Triggering/Retriggering of Panic or Duress will activate the according output types and activate the transmission.

"Retrigger Duress" to enable retriggering of Duress alarms without restoring the alarm.

"Retrigger Panic" to enable retriggering of Panic alarms without restoring the alarm.

Previously the Duress and Panic alarms were only triggered once and had to be restored before they could be triggered again.

All

Page 22: Release Note SPC42xx43xx52xx53xx63xx V3.2.2 En

s Building Technologies Division: Security Products Page: 22 / 23 release_note_spc42xx43xx52xx53xx63xx_v3.2.2_en.doc

Extended Policy options NEW Extended System Options (WEB interface only) have been added to define

system behavior (Policy) for specific aspects. These options are only available when Standards are set to “Unrestricted”. Available policies are (new and existing).

System Alert Policy to configure processing of system alerts

Zone Alarm Policy to configure processing of zone alarms.

Zone Tamper Policy to configure processing of zone tampers.

Keypad Display Policy to configure displayed event texts on keypad.

Keypad LED Policy to configure displayed LED’s on keypad.

System Policy to configure general system behavior.

Timing Policy to view settings of system timers.

These options are normally used to tune the system to pass local approvals.

All

SWISSI standard requirement NEW New options have been added to comply with the Swiss approval standard:

New Regional setting option to comply with Swiss CAT1/CAT2 approval requirements.

New System Option “Alarm on Exit”. If enabled, an alarm is raised if any entry/exit zone is still open when the exit timer expires. Otherwise the system will fail to set if any entry/exit zone is still open. Note: For all other regions than Switzerland this option is disabled and only available when ‘Unrestricted’ grade is selected as setting is not in accordance with EN50131.

New System Option “Alert Forbid Set”: If set a user cannot set an area with pending alerts or system alerts.. Note: For all other regions than Switzerland this option is disabled and only available when ‘Unrestricted’ grade is selected

User keypad lockout times for the Swiss standard for CAT1/CAT2 are the same as applied to EN Grade 3.

All

Alterations for EN50131 compliance CHANGE The following functional changes were made due to change of interpretation

to comply with EN50131-3:2009 when Grade 2 or 3 is selected.

X-BUS expander and keypad communication loss events should be processed as tamper and not fault.

Users are not allowed to restore faults in EN5031 Grade 3 configurations.

Prevent from setting if Alarm Transmission fault

Prevent from setting if Warning Device Fault (bell tamper)

Prevent from setting if ATS (Alarm Transmission System) faults (e.g.

All

Page 23: Release Note SPC42xx43xx52xx53xx63xx V3.2.2 En

s Building Technologies Division: Security Products Page: 23 / 23 release_note_spc42xx43xx52xx53xx63xx_v3.2.2_en.doc

Communication Fault, Modem Fault, Line Fault)

Connection to SPC control panel via USB port sometimes doesn’t work CORRECTION When using the USB port for local connection of PC/Laptop to SPC control

panel with PCB revision 1.4 or lower, the connection couldn’t be established every time, even the SPC driver recognized that a panel was connected. This behavior is corrected with this version.

All