reliable pumps for oil and gas processing with no …...crude oil (transfer, sampling) range of...
TRANSCRIPT
Oil &
Gas P
roce
ssing
Reliable Pumps for Oil and Gas Processing with No Dynamic Seals or Packing to Leak or Replace
2 • www.Hydra-Cell.com
Pressure Injecting and Mixing • Transfer • Spraying • Metering and Dosing
With more than 40 years of experience serving the industry, in-cluding many of the major global companies, Hydra-Cell pumps are performance-proved for continuous use in a wide range of oil and gas applications.
• Canpumpcorrosiveandabrasivefluids,evenathigh temperatures.
• Abletorundrywithoutdamage(oradditionalmaintenance) to the pump in case of accident or operator error.
• Minimizesmaintenancebecausetherearenomechanicalseals, packing, or cups to leak or replace.
Field Production and Transport Applications • HotGlycolInjection
• ProducedWaterInjection,Disposal&Transfer
• CondensateTransfer&Injection
• SourService
• ChemicalInjection
Refinery Applications • CatalyticInjection
• CrudeOilSampling
• HighPressureWater
• CausticSodaWashDown
• SourGasInjection
• EmissionControl
• PumpingSlurryforSO2Removal/AcidicNeutralization
Hydra-Cell pumps are used for many oil and gas process-ing applications.
Offshore (Chemical Injection & Reverse Osmosis)
GasExtraction (Water Reinjection, Well Dewatering & NGL Transfer)
GasProcessing&Distribution(Glycol Injection and Odorizing)
OilRefining (Steam, Stripping, Additive Injec-tion, Stack Cooling & Chemical Metering)
JetPumps (Power Fluid Pressurization)
PressureTesting (Pipes and Well Testing)
OilExtraction (Well Simulation, Water Reinjec-tion, Chemical Injection)
CrudeOil (Transfer & Sampling)
Hyd
ra-C
ell
® P
um
ps
for
Oil
& G
as
Pro
cess
ing
Hydra-Cell Pumps Selection and ApplicationsHydra-Cell positive displacement pumps are available in sev-eraldifferentmodeltypestocoverawiderangeofflowsandpressure in different applications.
Ten(10)Hydra-CellSeal-lessmodels are ideal for transfer, spraying, and pressure inject-ing and mixing.
Seven(7)Hydra-CellMeter-ingSolutionsmodelsthatareideal for metering and dosing, spraying, and pressure injec-tion and mixing.
Four(4)Hydra-Cellsolenoid/electronic diaphragm meter-ing pump models ideal for low-flow,low-pressurechemi-cal injection.
Three(3)Hydra-CellT100Seriestriplexandtwo(2)Hydra-CellQ155Seriesquintuplex pumps for larger capacities.
Compact, Seal-less Pumps for Reliable Operation and Long Service Life
“Before we installed our Hydra-Cell pump, we were using a
plunger pump. And, anytime you run a plunger pump you’re going
to get some leakage in the packing or they end up burning out.
At the speed we needed to run them at, they were burning up
packing quite regularly. So we replaced our old plunger pumps
with D04 Hydra-Cell pumps and since then we haven’t had an
issue. Their durability and seal-less design have helped us reduce
costly maintenance.”
DenisBoucher ProductionForeman TridentExplorationGroupInc.
www.Hydra-Cell.com • 3
Hyd
ra-C
ell
® Pu
mp
s for O
il & G
as P
roce
ssing
Produced Water & Sour Water(Injection,Disposal,Transfer)
Corrosive – can contain H2S,salt,CO2 plus other impurities forming acidic solutions that can damage a pump.
Abrasive–watercontainssandandothercontaminants(e.g.)barium,cadmium,sulfur,chromium,copper,iron,lead,nickel,silver,zinc.
H2Sgasmaynotbefullycontainedbypackingorseals.
• Seal-lessdesignprovidesnoleakpathandhandlescorrosivefluids.
• Corrosion-resistantliquidendmaterialsavailable.
• Seal-lessdesignandspring-loaded,horizontaldiskcheck valves enable liquids with particulates up to 800microns(dependingonpumpmodel)tobepumped reliably without damage to the pump.
• Nodynamicsealstowear.
• Nocups,packingordynamicsealstoleakgas.• Seal-lesspumpchamberprovides100%
containment.
Hot Triethylene Glycol (TEG)Diethylene Glycol (DEG)(GasDrying)
Non-lubricating–requiresinternalgearingorreservoir with added maintenance issues.
Handling high temperature of liquid pumped.
ControllabilityofinjectedTEG/DEG.
• Pumpingactiondoesnotrequirelubrication.
• Nodynamicsealstobedamaged.
• Flowratedirectlyproportionaltopumpspeed.• Shaftspeedadjustablerangefrom10to1800rpm
(1200rpmforsomemodels).
Methanol(WellIcingPrevention)
Non-lubricating,especiallypumpingatpressure. • Pumpingactiondoesnotrequirelubrication.
Natural Gas Liquids(MixturesofMethane,Propane,Ethane)
Non-lubricating–requiresinternalgearingorreservoir with added maintenance issues.
• Pumpingactiondoesnotrequirelubrication.
Amines(Monoethanolamine,Diethanolamine,Methyldiethanolamine,Diglycolamine)
DifficulttocontainanyH2Ssaturatedinanamine.
Controlofflowratemustberesponsiveandaccurate.
• Seal-lesspumpchamberprovides100%containment.
• Utilizesspeedcontrolforgreateraccuracy.• ExceedsAPI675performancecriteriaforlinearity
(speed/flowraterelationship).
Caustics(SodiumHydroxide,PotassiumHydroxide)
Tendtocrystallizewhencoldorincontactwithair,forming solids that can damage mechanical seals, cups, packing, and other pump components that require a lubricatingfilm.
• Seal-lessdesignmeansnorotaryshaftsealstowear or replace, preventing air and moisture contamination.
• Spring-loaded,horizontaldiskcheckvalvesenableliquidswithparticulatesupto800micronsinsize(dependingonpumpmodel)tobepumpedreliablywithout damage to the pump.
Acids(Sulfuric,Hydrochloric,Nitric)
Corrosive – can damage pump.
Tendtocrystallizewhencoldorincontactwithair,forming solids that can damage mechanical seals and other pump components that require a lubricating film.
• Seal-lessdesignprovidesnoleakpathandhandlescorrosivefluids.
• Corrosion-resistantliquidendmaterialsavailable.
• Seal-lessdesignandspring-loaded,horizontaldiskcheck valves enable liquids with particulates up to 800microns(dependingonpumpmodel)tobepumped reliably without damage to the pump.
Condensates(Field,Lease)
Non-lubricating–requiresinternalgearingorreservoir with added maintenance concerns.
Mustbe100%containedtocomplywithVOCemissions legislation.
• Pumpingactiondoesnotrequirelubrication.
• Nocups,packingordynamicsealstoleakgas.• Seal-lesspumpchamberprovides100%
containment.
Polymers(WellSimulation)
Shear-sensitivegelstructurescanbebrokendowneasily.
Difficultlyinpumpinghigh-viscosityfluids.
Abrasive–containssodaash.
Controlofflowratemustberesponsiveandaccurate.
• Provideslow-shearpumpingactionandvirtuallypulse-lessflowthatprotectpolymers.
• Low-shearpumpingactionalsohandleshigher-viscosityfluids.
• Seal-lessdesignandspring-loaded,horizontaldiskcheck valves enable liquids with particulates up to 800microns(dependingonpumpmodel)tobepumped reliably without damage to the pump.
• Utilizesspeedcontrolforgreateraccuracy.• ExceedsAPI675performancecriteriaforlinearity
(speed/flowraterelationship).
Crude Oil(Transfer,Sampling)
Rangeofviscositiesmakesitdifficulttopump. • Seal-lessdesignandlow-shearpumpingactionenablehandlingofliquidswithviscositiesfrom0.01to5000cPsormoreaswellasliquidscontainingamixture of viscosities.
Typical Chemicals and Liquids Pumped
Challenges in Pumping
The Hydra-Cell Advantage
4 • www.Hydra-Cell.com
Lower Initial Investment and Lower Energy Costs
Uses lower hp motors• Althoughbothmeteringpumpshavethesamepressurerating,thelighter,morecompactHydra-Cellhasahigherflowratingwhilerequiringalessexpensive,lowerhpmotor.ThismeansHydra-Cellsavesapproximately30%to55%oninitialcosts.
Hyd
ra-C
ell
® D
esi
gn
& P
erf
orm
an
ce F
eatu
res
The multiple-diaphragm liquid head of Hydra-Cell also allows a less expensive, energy-saving motor to be used.
Hydra-Cell metering pump
Weight:83.5lbs.(withmotor)
Rated:2500psiat35gph
Motor:1-1/2hp
Conventional metering pump
Weight:220lbs.(withmotor)
Rated:2500psiat29gph
Motor:5hp
Low power consumption - 85% to 90%
energy efficiency • ThelowerhprequirementoftheHydra-Cellpumpachievesthesameperformancebutwithgreaterenergyefficiencyandlesspower consumption.
• Hydra-Cellpositivedisplacementpumpsshowsignificantenergysavings when compared to screw pumps and multi-stage cen-trifugal pumps.
Small footprint for savings• Compactdesigncanmeanupto30%lowerinitialcostcompared
to other pumps.
• Space-savingdesigncreatesasmallerfootprintformoreefficientuse of plant space.
• Easiertoaccessforroutinemaintenanceorservicing.
This Hydra-Cell pump shown to scale has the same flow capacity and pressure rating as this conventional triplex metering pump system.
Comparedwithmulti-stagecentrifugalpumpsforfluidpumpedat290psi.
Flow(ft3/hr)
EnergyUsed(kW)EnergySaving
PotentialAnnualSavings*
Centrifugal Hydra-Cell
21 1.54 0.50 67% $280
53 2.0 1.44 28% $151
Flow(ft3/hr)
EnergyUsed(kW)EnergySaving
PotentialAnnualSavings*
Centrifugal Hydra-Cell
148 9.34 6.10 35% $875
268 15.40 11.00 28% $1,188
Comparedwithmulti-stagecentrifugalpumpsforfluidpumpedat580psi.
* Based on pumps running 2,000 hr/yr @ USA average of 13.5¢/kWh.
Pumps Shown to Scale
Pumps Shown to Scale
www.Hydra-Cell.com • 5
Hyd
ra-C
ell
® De
sign
& P
erfo
rman
ce F
eatu
res
“We’ve had our pump for three years – four years this fall and it’s been
great. There’s very little maintenance and it’s cost effective to run.”
PatHollman SeniorOperator MacklinFacility•HuskyEnergy
Pumps Abrasives and Runs Dry without Damage
Handles abrasives and particulates• Seal-lessdesignandspring-loaded,horizontaldiskcheckvalves
provide superior handling of abrasives and particulates.
• Efficientpumpingofliquidswithsolidparticlessuchaslimeslurries and sour water containing sand. Can handle abrasive fillersandparticulatesupto800micronsinsize(dependingonpumpmodel)andupto9hardnessontheMohsscale.
Runs dry without damage• Hydraulically-balanceddiaphragmswithpatentedKel-Cell®
technology enable Hydra-Cell pumps to run dry or in a blocked suction line or valve closure without damage.
Handles low-to-high viscosity fluids• Pumpsnon-viscousaswellasviscousliquidsupto5000cPs(ormore,dependingonpumpmodel)throughouttheentirepressure range.
• Low-shearpumpingactionmakesHydra-Cellidealforpumpingand protecting shear-sensitive polymers.
• Non-lubricatingliquidscanbepumpedreliably.
Hydra-Cell’s horizontal check valve orientation will handle abrasives and particulates without clogging or damage to the pump.
Hydra-Cell pumping shear-sensitive polymers for enhanced oil recovery.
6 • www.Hydra-Cell.com
Hyd
ra-C
ell
® D
esi
gn
& P
erf
orm
an
ce F
eatu
res
Reliable Pump Design for Low Maintenance
No dynamic seals, cups, or packing to leak,
wear or replace• Sincetherearenodynamicsealstowearorreplace,Hydra-Cell
pumps need little maintenance and will operate reliably under continuous duty at high pressure.
• Notighttolerancesthatcouldbesusceptibletocorrosionordamaged by solid particles.
• Nodrop-offinperformancecommontosealedpumpsastheseals wear.
Environmental protection - no harmful emissions• Liquidsare100%sealedfromtheatmosphere.
• NoleakpathfortoxicvaporsorharmfulgasessuchasH2S.
• NodynamicsealssothereisfullcontainmentofVolatile OrganicCompounds(VOC).
Built for continuous duty and long
service life• Onedesignforallapplicationsminimizestheneedforstandbypumpsandspareparts,whichoptimizestrainingandserviceexpertiseandreducesinventorysizeandexpense.
• Canoperateupto6,000hoursbetweenlubricatingoilchanges(comparedto1,500hoursrecommendedbymanypistonpumpmanufacturers).
Simple pump head design• Liquidheadmaterialscanbechangedreadily,enablingHydra-Cell
to be used for many different chemicals and liquids pumped.
• Minimalmaintenancerequired.
• Lowcostofspareparts.
Reduced filtration maintenance and management• Nodynamicsealsortighttolerancesthatneedprotectionbyfinefiltration.
• Pumpsparticulatesandabrasivesupto800micronsinsize(dependingonpumpmodel)whichcaneliminatetheneedforfinefiltration.
• Canpumpliquidswithnon-dissolvedsolidsupto40%,dependingon particle distribution.
• Unaffectedbylapsesinfiltration,reducingcostlypumprepairs.
Adaptable to many applications• OneHydra-Celldesignwith22models(10seal-less;7metering;5largecapacity)coversawiderangeofoperatingflowsandpressures.
• CanbefittedwithANSI,SAEorDINflanges,IECorNEMAmotormounts,orprovidedwithATEXcertificationtoadapttospecificapplicationsormeetinternationalstandards.
• Provenrecordofreplacingdifferentpumptechnologieswithimprovedabrasiveshandling,lessmaintenance,andotherbenefits(asdetailedonpages8-10).
“The longevity of the pump is what makes it such a great tool.
With the Hydra-Cell, we just don’t have any of the packing or
leaking issues that most normal pumps do.”
TrevorClay, FieldOperator TalismanEnergy
Hydra-Cell pumps shown processing volatile crude oil.
www.Hydra-Cell.com • 7
Hyd
ra-C
ell
® De
sign
& P
erfo
rman
ce F
eatu
res
Accurate Metering and Dosing with Pulse-free, Linear FlowAccurate electronic flow control• Comparedtopumpsthatrelyonmanualstrokeadjustmentorexpensiveactuatorstochangeflow,Hydra-Cellmeteringpumpsutilizespeedcontrolforgreateraccuracythroughouttheturndown range.
• Canbeequippedwithsolid-stateelectronicflowcontrolwherethe volume per every stroke is constant and a known value.
• Electronicflowalsoprovideseasycalibrationofthedesiredfeedrateandanearinstantaneousrateofchange(0tomaximumrpmin0.3seconds).
Virtually pulse-free
flow• Multiple-diaphragmdesignminimizespulsations,eliminating the need for expensive pulsation dampeners for most Hydra-Cell models.
• Reducespipestrain.
• Enhancesoperatingsafety.
• Minimizesmaintenance.
• Reducesacceleration/frictionlosses in the suction line.
• Providesaccuratemeteringwithlinear,constantflow.
• Lowerssystemacquisitioncosts.
0
5 . 1 5 2 . 1 1 5 7 . 0 5 . 0 5 2 . 0 0
Time: seconds
Pre
ssu
re: p
si (b
ar)
Pulsation Graph ComparisonMetering Pumps Operating without Pulsation Dampeners
Flow Rate: 182 gph (689 lph) • Pressure: 100 psi (6.9 bar)
Hydra-Cell
P400
Conventional
Metering Pump
150
(10.3)
100
(6.9)
50
(3.4)
Versatility for Field and Refinery ApplicationsVariety of pipe connections
ANSI flange connectionsSAE flange connections
NPT or BPST threaded connections
Variety of liquid end materialsAchoiceofliquidendmaterialsisavailabletosuitthefluidbeingpumped:
• HastelloyC • DuplexAlloy2205SST
• 316LSST • Brass
• 304SST • Bronze
• CastIron • Polypropylene
• DuctileIron • PVDF
Variety of diaphragm materialsDiaphragmsareavailableinachoiceofmaterialstooperateoverawide range of processing and performance conditions:
• EPDM • FKM
• PTFE • Neoprene
• Buna-N • Aflas
Hydra-Cell
Seal-less
Models
Hydra-Cell
P Series
Metering Pumps
SteadyStateAccuracy
±1% ±1%orbetter
Repeatability ±3% ±3%orbetter
Linearity ±3% ±3%orbetter
Typical results for recommended speed range
8 • www.Hydra-Cell.com
Hyd
ra-C
ell
® C
ompe
titiv
e Pe
rfor
man
ce A
dvan
tage
s
• Packingrequiresfrequentadjustmentsandthenreplacement as it wears.
• Seal-lessdesignusesnopacking,reducingdowntimeandmaintenance costs.
• Packingmustleaktoprovidelubrication–creating maintenance, containment, disposal, safety, and housekeeping issues with their associated costs.
• Nopackingmeansnosecondarycontainmentrequirements,no clean-up or disposal issues, improved safety, and reduced maintenance costs.
• Packingallowsemissionsthatrequireexpensive “vapor-less” alternatives or vapor recovery systems.
• Seal-lessdesigneliminatesemissionsandcostlyassociatedfines.
• Packingcausesplungerwear,whichismadeworsebyabrasivemedia;theplunger,stuffingbox,andpackingmust be compatible with the product being pumped.
• Diaphragmdesignallowspumpingofabrasiveandcorrosive media without concern for wear, compatibility or replacement of packing or plunger/piston.
• Mayrequireexternallubricationsystemsatanadditionalcostofupto$3,000–anothermaintenanceandrepairfactor.
• Nolubricationnecessary,resultinginlessmaintenanceand lower cost of ownership expenses.
Hydra-Cell® Performance Advantages Compared to Other Types of Pumps
Hydra-Cell Advantages:Plunger/PistonPumpDisadvantages:
• Usemanualstrokeadjustersorexpensiveactuatorstocontrolflow,whichcanresultinpumpinginaccuracies,lost motion, operator error, and a greater chance of leakage.
• Hydra-CellemploysoptionalVariableFrequencyDrive(VFD)electronicflowcontrolforgreateraccuracyandrepeatability, eliminating lost motion, reducing the chance of operator error, and removing a potential leak path.
• Requireexpensivepulsationdampenerstominimizepulsations.
• Multiple-diaphragmdesignprovidesvirtuallypulse-freeflow,soexpensivepulsationdampenersmaynotberequired.
• MayonlyofferPTFEdiaphragms,requiringfrequentreplacement due to stress and poor elastomeric memory.
• Availablewithawidechoiceofcost-effective,elastomericdiaphragm materials.
• Largefootprinttoachieverequiredmaximumflowandpressure.
• Canmeetthesameflowandpressurerequirementswitha much smaller footprint, saving space and costs.
• Differentplungerandliquidendsizesneededtoaccommodate changes in operating pressures.
• Operatesoverawiderangeofpressureswithoutchangestotheplungerorliquidendsize.
• Integralgearing(necessarytopreventcross-contaminationofactuatingoil)isdifficultandexpensiveto maintain.
• Thesimplicityofdesignmeanslowerpartsandmaintenance costs.
• Separategearboxpreventscross-contaminationoftheactuating oil.
Hydra-Cell Advantages:ConventionalMeteringPumpDisadvantages:
Plunger pumps (shown) have maintenance, wear, lubrication, and environmental issues that Hydra-Cell pumps avoid because of the seal-less, multiple-diaphragm design of Hydra-Cell.
www.Hydra-Cell.com • 9
Hyd
ra-C
ell ® Com
petitive Performance A
dvantages
• Mechanicalsealsandpackingrequiremaintenance,andreplacement or adjustment.
• Theseal-lessdesignofHydra-Cellmeansthatthereareno mechanical seals or packing to leak or replace.
• Doesnottoleratethin/non-lubricatingliquids,anddoesnot handle solids, abrasives or particulates well.
• Seal-lesspumpingchamberandspring-loaded,horizontaldiskcheckvalvescanpumpsolids,abrasivefillersandparticulates while handling liquids thick or thin.
• Designedforoperatingatlowspeedsandlowpressureratings.
• Lowvolumetricefficiency.
• Operatesatlow-to-highspeedsandathigherpressureswithhighervolumetricefficiency.
• Componentwearreducesaccuracyandefficiency. • Nointernalgearstowearsothereislessmaintenanceand spare part replacement.
• Accuracyandefficiencyaremorestable.
• Onebearingrunsinthepumpedfluid. • Nobearingsinthepumpedfluid.
• Unbalanced-overhungloadontheshaftbearing. • Hydraulicallybalanceddesignsothereisnooverhungload.
Hydra-Cell Advantages:InternalGearPumpDisadvantages:
• Mechanicalsealsandpackingrequiremaintenance,andreplacement or adjustment.
• Theseal-lessdesignofHydra-Cellmeansthatthereareno mechanical seals or packing to leak or replace.
• Doesnottoleratesolids,abrasives,orparticulates. • Seal-lesspumpingchamberandspring-loaded,horizontaldiskcheckvalvescanpumpsolids,abrasivefillersandparticulates.
• Componentwearreducesaccuracyandefficiency. • Nointernalgearstowearsoefficiencyismorestable and there is less maintenance and spare part replacement.
• Containsfourbushings/bearingsinthefluidarea. • Nobushings/bearingsinthepumpedfluid.
• Fixedendclearances. • Designdoesnotrelyonclearances.
• Efficiencydropsasoutletpressureincreases. • Efficiencyremainsrelativelyconstantoveritsrangeofoperating pressures.
• Dependsonpumpedliquidforlubrication. • Seal-lessdesigndoesnotrequirepumpedliquidforlubrication.
Hydra-Cell Advantages:ExternalGearPumpDisadvantages:
Compared to other pumps, Hydra-Cell requires minimal maintenance for oil and gas processing. Hydra-Cell has no mechanical seals, cups, or packing that leak or need to be replaced and no internal gears to wear.
10 • www.Hydra-Cell.com
Hyd
ra-C
ell
® C
ompe
titiv
e Pe
rfor
man
ce A
dvan
tage
s Hydra-Cell® Performance Advantages Compared to Other Types of Pumps
• Dynamicsealsarewornbypumpingabrasivefluids. • Nodynamicsealsinthepumpedfluid;canhandleabrasivefluidsreliably.
• Hydrodynamicfilmbetweenthestatorandrotorcambreaksdownunderpressure,reducingflowrateandnegating true positive displacement pumping action.
• Seal-lesspumpchamberwithhydraulically-balanceddiaphragmsmeanthatflowrateismaintainedevenasdischarge pressure increases.
• Runningdrycanresultindamagetothepump. • Seal-lessdesignenablesHydra-Celltorundrywithoutdamage to the pump.
• Higherpressurerequiresadditionalstageswithanincreasingfootprintforhorizontalpumps.
• Canmeetthesameflowandpressurerequirementswith a much smaller footprint, saving space as well as investment and operation costs.
Hydra-Cell Advantages:ProgressiveCavityPumpDisadvantages:
• Mechanicalsealsandpackingrequiremaintenanceandreplacement or adjustment.
• Theseal-lessdesignofHydra-Cellmeansthatthereareno mechanical seals or packing to leak or replace.
• Particulatesandfinesinthepumpedfluidwillcausewearin the case and the impellers.
• Seal-lesspumpingchamberwithspring-loaded,horizontaldiskcheckvalvescanpumpparticulatesandfinesupto800micronsinsize(dependingonpumpmodel).
• Difficulttomaintainhighefficiencywhilevaryingoutletpressure.
• Designedforefficient,high-pressuredelivery.
• Runningdryandairentrapmentcancausecatastrophicfailure.
• Canrundrywithoutdamagetothepump.Entrappedairdoes not cause immediate failure.
• Ineffectiveatlowspeedsandhighoutletpressures. • Runsatverylowspeeds(from18to1800rpm)whilemaintaining outlet pressures.
• Flowrateisdifficulttocontroleffectively. • Positivedisplacementdesignallowsforaccuratespeedcontrol.
• Higherpressurerequiresadditionalstageswithanincreasingfootprintforhorizontalpumps.
• Canmeetthesameflowandpressurerequirementswith a much smaller footprint, saving space as well as investment and operation costs.
Hydra-Cell Advantages:CentrifugalPump(Multi-stage)Disadvantages:
Hydra-Cell features a seal-less design that separates the liquid end from the hydraulic end, enabling the pump to tolerate solids, abrasives, and particulates, handle non-lubricating fluids, and run dry without damage to the pump.
www.Hydra-Cell.com • 11
Hyd
ra-C
ell ® S
tan
dard
Pu
mp
Sele
ction
Gu
ide
• Unmatchedversatilityforawiderangeofpumpingapplicationsrequired in oil and gas processing.
• Featuresaseal-lessdesignandhorizontaldiskcheckvalvesthatenable the pump to handle abrasives and particulates that might damage or destroy other types of pumps.
• Simple,compactdesignreducesinitialinvestmentandlowersmaintenance costs.
• Varietyofmodelsthatcanoperatewithverylowtoveryhighflowratesanddischargepressuresupto2500psi.
• Availableinawiderangeofpumpheadmaterialsofconstructionand diaphragm materials.
• Varietyofoptionsandaccessoriestooptimizeperformance.
InhisworkthroughoutSouthernandCentralCalifornia,SteveBurksofOilFieldSolutions,hasfounditchallengingattimes to get customers to change the way they operate.
“But once I get them using a Hydra-Cell and they see the
difference it can make in reducing maintenance headaches and
operating costs for their well operations, they are all for it.”
SteveBurks Owner OilFieldSolutions
Seal-less Pumps
Hydra-Cell Positive Displacement Diaphragm Pumps are Ideal for Handling Abrasives and Particulates
PU
MP
S
DESIGNED &
BU
ILTSINCE
1973
SINCE
1973I N T H E U S A
1 Ratings are for X-cam design.2 350 psi (24 bar) maximum with PVDF liquid end; 250 psi (17 bar) maximum with Polypropylene liquid end.3 Consult factory for correct component selection from 160˚F (71˚C) to 250˚F (121˚C).4 D10 @790 rpm maximum.5 D35 @700 rpm maximum.
For complete specifications and ordering information, consult the Hydra-Cell catalog.
Flow Capacities (barrels per day) and Pressure Ratings MaximumCapacity MaximumDischargePressurepsi(bar) MaximumOperatingTemperatureF(C)3 MaximumInlet Model1 BPD gpm l/min Non-metallic2 Metallic Non-metallic Metallic Pressurepsi(bar)
F20 34 1.0 3.8 350(24) 1000(69) 140˚(60˚) 250˚(121˚) 250(17)
M03 106 3.1 11.7 350(24) 1000(69) 140˚(60˚) 250˚(121˚) 250(17)
D04 99 2.9 11.2 N/A 2500(172) N/A 250˚(121˚) 500(34)
D104 147 4.3 15.1 N/A 1500(103) N/A 250˚(121˚) 250(17)
D10 301 8.8 33.3 350(24) 1000(69) 140˚(60˚) 250˚(121˚) 250(17)
D12 278 8.1 30.6 N/A 1000(69) N/A 250˚(121˚) 250(17)
D15 & D17 473 13.8 52.3 N/A 2500(172) N/A 250˚(121˚) 500(34)
H25 686 20.0 75.7 350(24) 1000(69) 140˚(60˚) 250˚(121˚) 250(17)
D355 792 23.1 87.5 N/A 1500(103) N/A 250˚(121˚) 250(17)
D35 1251 36.5 138.0 N/A 1200(83) N/A 250˚(121˚) 500(34)
D66 2253 65.7 248.7 250(17) 700(48) 140˚(60˚) 250˚(121˚) 250(17)
12 • www.Hydra-Cell.com
Flow Capacities and Pressure Ratings
1 Ratings are for X-cam design.
2 Consult factory for ratings in liters per hour (lph).
3 350 psi (24 bar) maximum with PVDF liquid end; 250 psi (17 bar) maximum with Polypropylene liquid end.
4 Consult factory for correct component selection for temperatures from 160˚F (71˚C) to 250˚F (121˚C).
Maximum MaximumDischarge MaximumOperating Maximum Capacity Pressurepsi(bar) TemperatureF(C)3 InletPressure Model1 gph Non-metallic2 Metallic Non-metallic2 Metallic psi(bar)
P100 27.0 350(24) 1500(103) 140˚(60˚) 250˚(121˚) 250(17)
P200 81.0 350(24) 1000(69) 140˚(60˚) 250˚(121˚) 250(17)
P300 81.4 N/A 2500(172) N/A 250˚(121˚) 500(34)
P400 242.8 350(24) 1000(69) 140˚(60˚) 250˚(121˚) 250(17)
P500 425.9 N/A 2500(172) N/A 250˚(121˚) 500(34)
P600 890.3 350(24) 1000(69) 140˚(60˚) 250˚(121˚) 250(17)
Hyd
ra-C
ell
® M
ete
rin
g P
um
p S
ele
ctio
n G
uid
eHydra-Cell P Series Metering Pumps Exceed API 675 Standards and Provide “Pulse-free” Linear Flow
• DesignedforusewithVariableFrequencyDrive(VFD)electronicflowcontroltomaintaingreateraccuracythroughouttheturndown range.
• Multiple-diaphragmdesign(excepttheP100)providesvirtuallypulse-freeflow,eliminatingtheneedtopurchaseexpensivepulsation dampeners.
• OffersallthefeaturesandbenefitsofstandardHydra-Cellpumps(F/M/D/HSeriespumps)includingseal-lessdesign,horizontaldiskcheckvalves,andspace-saving,compactdesign.
• Varietyofmodelsthatcanoperatewithverylowtoveryhighflowratesanddischargepressuresupto2500psi.
• Availableinawiderangeofpumpheadmaterialsofconstructionand diaphragm materials.
• Everymodelisavailablewithavarietyofgearboxratiostomeetyour application needs.
• Varietyofoptionsandaccessoriestooptimizeperformance.
“We use our Hydra-Cell to pump ethanol glycol for dehydrating
natural gas and it’s been working well. We’ve had it for over two
years and it’s easy to use and there’s minimal maintenance, which
makes for a longer lasting pump.”
BudBessler WorlandPlantManager HilandPartners
IChemE 2007
Honourable Mention
The IChemE Awards recognize innovation and excellence in making outstanding contributions to safety, the environment, and sustainable development in the chemical and bioprocess industries.
For complete specifications and ordering information, consult the Hydra-Cell metering pumps catalog.
www.Hydra-Cell.com • 13
Hyd
ra-C
ell ® M
ete
ring P
um
p S
ele
ction
Gu
ide
Hydra-Cell MT8 Triplex Metering Pumps and S Series Electronic Solenoid/ Diaphragm Metering Pumps NEW
MinimumFlowRate: 0.06gph(0.227lph)MaximumFlowRate 8.00gph(30.28lph)MaximumPressure: 3500psi(241bar)forMetallic PumpHeads
TheMT8meetsorexceedsAPI675performancestandardsforSteady-StateAccuracy(±1%),Linearity(±3%)andRepeatability(±3%).
Hydraulically-balanced and actuated, the pump features an
internal relief valve for added safety and cartridge check
valves for ease of maintenance.
SM030CAS manual control with stroke speed dial.
ST03RPES with pulse-in control, timer, and digital readout.
SA03RPES with pulse-in/analog-in control and digital readout.
SP060HVS with pulse-in control and digital readout.
TheSSeriespumpsprovideaneconomicalchoiceforchemicalinjectioninmeteringapplications.Solenoiddriven,theSSeriespumpsfeatureawidedischarge-volumerange,extensive choice of liquid end materials, various control
functions, and a wide voltage range.
Double-ballcheckvalvesensuresaccuratemeteringandreduces the chance of water hammer, and an anti-syphon
check valve prevents clogging at the injection point and aids
in priming.
“Eco-friendly”environmentallysoundoperationisstandardwithSP,ST,andSAmodels.Thisfeaturecanlowerpowerconsumptionupto55%.
SM Series SP/ST/SA Series Flow Rate Models Models
30ml/min* SM030 SP/ST/SA-030
60ml/min SM060 SP/ST/SA-060
100ml/min SM100 SP/ST/SA-100
220ml/min N/A SP/ST/SA-200
With Relief Valve
30ml/min* SM03R SP/ST/SA-03R
60ml/min SM06R SP/ST/SA-06R
100ml/min SM10R SP/ST/SA-10R
* High-pressure models have maximum flow rates of either 25 or 28 ml/min. Consult S Series catalog for more information.
New groundbreaking MT8 triplex metering pumps are currently available with a 316 SS liquid end and check valves plus PTFE diaphragms.
14 • www.Hydra-Cell.com
Seal-less Pumps
Hydra-Cell T and Q Series Pumps
T and Q Series Design Features• Seal-lessdesignseparatesthepowerendfromtheprocessfluidend,eliminatingleaks,hazardsandtheexpenseassociatedwithseals and packing.
• LowNPSHrequirementsallowforoperationwithavacuumcondition on the suction - positive inlet pressure is not necessary.
• Canoperatewithaclosedorblockedsuctionlineandrundryindefinitelywithoutdamage,eliminatingdowntimeandrepaircosts.
• Uniquediaphragmdesignhandlesmoreabrasiveswithlesswearthan gear, screw or plunger pumps.
• Hydraulicallybalanceddiaphragmshandlehighpressureswithlow stress.
• Provideslow-pulse,linearflowduetoitsmultiple-diaphragmdesign.
• Lowerenergycoststhancentrifugalpumpsandother pump technologies.
• Ruggedconstructionforlonglifewithminimal maintenance.
• Compactdesignanddouble-endedshaftprovidesavarietyofinstallation options.
For complete specifications and ordering information, consult the Hydra-Cell T100 & Q155 product bulletins.
Available
to Meet
API 674!
T100 Low Pressure Model
Hydra-Cell model T100 was a finalist in the Pumps & Systems “Product Innovation” awards, and the T100 Series earned a “Spotlight on New Technology” award from the Offshore Technology Conference.
Hyd
ra-C
ell
® T
& Q
Ser
ies H
igh
Pow
er P
umps
T100 High Pressure Model
Q155 Medium Pressure Model
NEW
Maximum Discharge Maximum Discharge Maximum Capacity Pressure Maximum Capacity Pressure Model BPD gpm l/min psi (bar) Model BPD gpm l/min psi (bar) T100E 3292 96.0 366.1 1500(103) Q155E 5383 157 595 1500(103)
T100F 2623 76.5 289.6 1850(128) Q155F 4354 127 490 1850(128)
T100H 2332 68.0 257.8 2100(145) Q155H 3806 111 421 2100(145)
T100K 1543 45.0 170.4 3000(207) Q155K 2674 78 295 3000(207)
T100M 1302 38.0 143.8 3500(241) Q155M 2228 65 246 3500(241)
T100S 891 26.0 98.4 5000(345)
Maximum Inlet Pressure for all models: 500 psi (34 bar).Maximum Operating Temperature for all models: 180˚F (82˚C). Consult factory for correct component specification for temperatures above 180˚F (82˚C) or below 40˚F (4˚C)
www.Hydra-Cell.com • 15
Wanner Engineering A
dditional Product LinesNon-metallic ANSI Centrifugal Pumps
Designed to handle difficult process fluids, Stan-Cor pumps offer total dynamic head to 350 feet and flow rate capacities to 700 gpm (2650 l/min).
• SolidPVDFpumpheadforchemical compatibility and excellent abrasion resistance.
• Operatewithasmooth,full-curveperformance.
• Concentriccasingdesignforbetterflowpatternsthan other centrifugal pumps - less turbulence, longerseallife,andreducedshaftdeflection.
• Handleshighoperatingtemperatures.
• Compactdesignfeaturesincludingheavy-dutydriveshaft, adjustable bearing supports, and large-capacity oil bath ensure low maintenance as well as durable performanceforthetoughestfluidapplications.
• Backpull-outdesignforeasyservicing.
• Handlessolidsizesupto9/16”maximum.
Peristaltic Pumps that Isolate the Pumped Fluid
Nine 2000 Series Vector pump models offer maximum flow rates from 0.3 gpm (1.1 l/min) to 211 gpm (798.7 l/min) and discharge pressures from 30 psig (2.1 bar) to 116 psig (8 bar) depending on pump model. Model 3005 provides up to 9.2 gpm (34.8 l/min) at 200 psig (13.8 bar).
Seven 4000 Series Vector pump models offer maximum flow rates from 0.79 gpm to 154.1 gpm and discharge pressures of 110 psig or 218 psig depending on pump model.
• Drypumpcavity.
• Self-primingoperation.
• Runsdrywithoutdamagetothepump.
• Completeisolationofthefluidbeingpumpedfromcontactwithmechanicalpartsforthefluidtransportsystem.
• Heavy-dutyrollerbearings.
• Widerangeofpumpconfigurationsandflowrates.
• Nocups,packing,ordynamicsealstoleakorreplaceorcomeindirectcontactwiththepumpedfluid.
• Lowmaintenance.
• Reversibleflow.
Printed in USA ©Wanner Engineering, Inc. HC/O&GB04.17RevB
Seal-less Pumps
World Headquarters & ManufacturingWannerEngineering,Inc.1204ChestnutAvenue,Minneapolis,MN55403USAPhone:612-332-5681•Fax:612-332-6937Toll-FreeFax(USA):800-332-6812Email:[email protected]
Regional Office207USHighway281WichitaFalls,TX76310USAPhone:940-322-7111Toll-Free:800-234-1384Email:[email protected]
Latin American OfficeR.ÁlvaroAnes,150BairroCampestreSantoAndré/SãoPaulo,Brazil-CEP09070-030Phone:+55(11)4081-7098Email:[email protected]
WannerInternational,Ltd.Hampshire-UnitedKingdomPhone:+44(0)1252816847Email:[email protected]
Wanner Pumps Ltd.
WannerPumps,Ltd.Kowloon-HongKongPhone:+85234286534Email:[email protected]
Shanghai-ChinaPhone:+86-21-68763700Email:[email protected]