remote methane leak detector rmld vs. flame ionization paul d. wehnert nysearch
TRANSCRIPT
![Page 1: Remote Methane Leak Detector RMLD vs. Flame Ionization Paul D. Wehnert NYSEARCH](https://reader035.vdocuments.net/reader035/viewer/2022062321/56649e385503460f94b285a6/html5/thumbnails/1.jpg)
Remote Methane Leak DetectorRemote Methane Leak DetectorRMLD vs. Flame IonizationRMLD vs. Flame Ionization
Paul D. Wehnert Paul D. Wehnert www.heathus.comwww.heathus.com
NYSEARCH
![Page 2: Remote Methane Leak Detector RMLD vs. Flame Ionization Paul D. Wehnert NYSEARCH](https://reader035.vdocuments.net/reader035/viewer/2022062321/56649e385503460f94b285a6/html5/thumbnails/2.jpg)
Innovation WinnerInnovation Winner
![Page 3: Remote Methane Leak Detector RMLD vs. Flame Ionization Paul D. Wehnert NYSEARCH](https://reader035.vdocuments.net/reader035/viewer/2022062321/56649e385503460f94b285a6/html5/thumbnails/3.jpg)
RMLD Key RequirementsRMLD Key Requirements
• Remotely detect methane up to 100’ away
• Portable, lightweight and rugged
• As effective as existing leak survey tools & methods
• Not intended to be a leak pinpointing or measurement tool (CGI)
• Specific to detect methane gas only
![Page 4: Remote Methane Leak Detector RMLD vs. Flame Ionization Paul D. Wehnert NYSEARCH](https://reader035.vdocuments.net/reader035/viewer/2022062321/56649e385503460f94b285a6/html5/thumbnails/4.jpg)
RMLD Operates Differently RMLD Operates Differently Than FIThan FI
• Remotely detects gas everywhere within the laser path length
• Measures PPM-Meter not PPM - PPM-Meter reading is concentration x
plume width
• Use of scanning techniques to detect and localize leaks
![Page 5: Remote Methane Leak Detector RMLD vs. Flame Ionization Paul D. Wehnert NYSEARCH](https://reader035.vdocuments.net/reader035/viewer/2022062321/56649e385503460f94b285a6/html5/thumbnails/5.jpg)
RMLD Verses FIRMLD Verses FIRMLD FI
DETECTION METHOD Tunable diode Laser Absorption SpectroscopySelective to Methane
Flame IonizationNon – selective hydrocarbon detector
MEASUREMENT RANGE
0 TO 99, 999 PPM –M 0 TO 10,000 PPM
SENSITIVITY 5 PPM-M @ distance from 0 to 50 ft.10 PPM-M or better @ distance from 50 to 100 ft.
2 to 50 PPM depending on model and type
DETECTION DISTANCE 100 ft. nominal. Actual distance may vary due to background type and conditions. Detects line of sight. Scanning technique
Probe technique - must be within the plume. Detects locally.
DETECTION ALARM MODES
Advanced detection signal processing method
Simple threshold alarm
![Page 6: Remote Methane Leak Detector RMLD vs. Flame Ionization Paul D. Wehnert NYSEARCH](https://reader035.vdocuments.net/reader035/viewer/2022062321/56649e385503460f94b285a6/html5/thumbnails/6.jpg)
RMLD Verses FI (Cont’d)RMLD Verses FI (Cont’d)RMLD FI
SELF-TEST & CALIBRATION
Built in Self-Test & Calibration verifies operation and adjusts laser wavelength for maximum sensitivity. Test cell integrated with carrying case.
Requires operator to use complex configuration of gas bottles and regulators.
POWER SOURCE Internal Battery Pack Hydrogen gas and internal battery
SAFETY IR Detector Laser: Class IGreen Spotter Laser: Class IIIa; do not stare into beam or view directly with optical instruments. Safer to use in traffic to survey gas lines remotely.
Requires the proper use and storage of highly flammable hydrogen gas.
Need to get in traffic lanes to survey gas lines, valves, etc.
![Page 7: Remote Methane Leak Detector RMLD vs. Flame Ionization Paul D. Wehnert NYSEARCH](https://reader035.vdocuments.net/reader035/viewer/2022062321/56649e385503460f94b285a6/html5/thumbnails/7.jpg)
RMLD FI
DISPLAY Large easy to read backlit LCD (.75” numeric)
Analog meter
OPERATING TEMPERATURE
0 TO +120 Degree “F” (-17 to 50 “C”)
0 to + 120 Degree “F” (-17 to 50 “C”)
HUMIDITY 5 to 95 % RH, non-condensing
5 to 95 % RH, non - condensing
ENCLOSURE IP 54 (water splash & Dust Resistant)
IP 54 (water splash & Dust Resistant)
OPERATING TIME 8 hours at 32 Degree “F” with out backlight on (internal battery)
3 hours before recharge of hydrogen bottle
RMLD Verses FI (Cont’d)RMLD Verses FI (Cont’d)
![Page 8: Remote Methane Leak Detector RMLD vs. Flame Ionization Paul D. Wehnert NYSEARCH](https://reader035.vdocuments.net/reader035/viewer/2022062321/56649e385503460f94b285a6/html5/thumbnails/8.jpg)
RMLD ConceptRMLD Concept
Do not need to be in gas plume!
![Page 9: Remote Methane Leak Detector RMLD vs. Flame Ionization Paul D. Wehnert NYSEARCH](https://reader035.vdocuments.net/reader035/viewer/2022062321/56649e385503460f94b285a6/html5/thumbnails/9.jpg)
Three Conditions Needed To Detect A LeakThree Conditions Needed To Detect A Leak• Need a sufficient plume to detect a leak
• The IR beam must pass through the plume
• Need a background target to reflect beam
![Page 10: Remote Methane Leak Detector RMLD vs. Flame Ionization Paul D. Wehnert NYSEARCH](https://reader035.vdocuments.net/reader035/viewer/2022062321/56649e385503460f94b285a6/html5/thumbnails/10.jpg)
Based On TDLAS Technology Based On TDLAS Technology • Tunable Diode Laser Absorption Spectroscopy
(TDLAS)- Every gas absorbs specific wavelengths
(frequencies) of light- The RMLD laser beam emits a specific wavelength
which is absorbed by methane- The amount of laser light absorbed is proportional to
the total amount of gas in the path of the laser beam- Concentration is then expressed as parts-per-million-
metered, or “ppm-m”. Concentration times plume width.
![Page 11: Remote Methane Leak Detector RMLD vs. Flame Ionization Paul D. Wehnert NYSEARCH](https://reader035.vdocuments.net/reader035/viewer/2022062321/56649e385503460f94b285a6/html5/thumbnails/11.jpg)
Technical ApproachTechnical Approach• Laser light beam is remotely projected on to a target (e.g., grass, wall,
etc.)• A fraction of the beam is scattered from the target surface and returned
to the source• Returned light is collected and focused onto a detector• The presence of methane is encoded within the returned light• Methane readings are displayed in ppm-m
DetectorLaser
Direct Sun and AmbientLight Adds DetectedBackground Photons
Light Becomes Electricity
Methane Leak
Topographic Backscatter ofLaser Light and BackgroundLight Collected by Receiver
![Page 12: Remote Methane Leak Detector RMLD vs. Flame Ionization Paul D. Wehnert NYSEARCH](https://reader035.vdocuments.net/reader035/viewer/2022062321/56649e385503460f94b285a6/html5/thumbnails/12.jpg)
![Page 13: Remote Methane Leak Detector RMLD vs. Flame Ionization Paul D. Wehnert NYSEARCH](https://reader035.vdocuments.net/reader035/viewer/2022062321/56649e385503460f94b285a6/html5/thumbnails/13.jpg)
Instrument DesignInstrument Design
![Page 14: Remote Methane Leak Detector RMLD vs. Flame Ionization Paul D. Wehnert NYSEARCH](https://reader035.vdocuments.net/reader035/viewer/2022062321/56649e385503460f94b285a6/html5/thumbnails/14.jpg)
RMLD PartsRMLD Parts
Complete Kit
The RMLD kit includes:
Control Module
Calibration Cell
Transceiver
Ear Piece Charger
Carrying Strap
External Battery(Optional)
![Page 15: Remote Methane Leak Detector RMLD vs. Flame Ionization Paul D. Wehnert NYSEARCH](https://reader035.vdocuments.net/reader035/viewer/2022062321/56649e385503460f94b285a6/html5/thumbnails/15.jpg)
Control Module - FrontControl Module - Front
![Page 16: Remote Methane Leak Detector RMLD vs. Flame Ionization Paul D. Wehnert NYSEARCH](https://reader035.vdocuments.net/reader035/viewer/2022062321/56649e385503460f94b285a6/html5/thumbnails/16.jpg)
Control Module – Rear PanelControl Module – Rear Panel
![Page 17: Remote Methane Leak Detector RMLD vs. Flame Ionization Paul D. Wehnert NYSEARCH](https://reader035.vdocuments.net/reader035/viewer/2022062321/56649e385503460f94b285a6/html5/thumbnails/17.jpg)
Internal BatteryInternal Battery
• Rechargeable Li-ion battery
• Life – 2 to 3 years• Charge last 8 hrs. @
32 deg. F• Cold weather and
constant use of spotter can drain battery faster
![Page 18: Remote Methane Leak Detector RMLD vs. Flame Ionization Paul D. Wehnert NYSEARCH](https://reader035.vdocuments.net/reader035/viewer/2022062321/56649e385503460f94b285a6/html5/thumbnails/18.jpg)
Volume LevelVolume Level
VOLVOL• Press up button to increase the volume level.• Press down button to decrease the volume level.
![Page 19: Remote Methane Leak Detector RMLD vs. Flame Ionization Paul D. Wehnert NYSEARCH](https://reader035.vdocuments.net/reader035/viewer/2022062321/56649e385503460f94b285a6/html5/thumbnails/19.jpg)
Spotter Enabling And Spotter Enabling And DisablingDisabling
SPOSPO• Press up button to enable or disable the spotter laser.
![Page 20: Remote Methane Leak Detector RMLD vs. Flame Ionization Paul D. Wehnert NYSEARCH](https://reader035.vdocuments.net/reader035/viewer/2022062321/56649e385503460f94b285a6/html5/thumbnails/20.jpg)
Alarm Detection ThresholdAlarm Detection Threshold
ALAL• Press Up button to increase the Alarm detection threshold.• Press Down button to decrease the Alarm detection threshold.
Higher threshold = Less sensitivity
![Page 21: Remote Methane Leak Detector RMLD vs. Flame Ionization Paul D. Wehnert NYSEARCH](https://reader035.vdocuments.net/reader035/viewer/2022062321/56649e385503460f94b285a6/html5/thumbnails/21.jpg)
Display BacklightDisplay Backlight
BACLIBACLI• Press Up button to turn on or to turn off the • display backlight.
![Page 22: Remote Methane Leak Detector RMLD vs. Flame Ionization Paul D. Wehnert NYSEARCH](https://reader035.vdocuments.net/reader035/viewer/2022062321/56649e385503460f94b285a6/html5/thumbnails/22.jpg)
DMD ModeDMD Mode
• To turn on the DMD mode, press the DMD button.• The DMD icon is displayed, as shown.
Note: You must be on the “run screen” to activate or de-activate DMD mode.
![Page 23: Remote Methane Leak Detector RMLD vs. Flame Ionization Paul D. Wehnert NYSEARCH](https://reader035.vdocuments.net/reader035/viewer/2022062321/56649e385503460f94b285a6/html5/thumbnails/23.jpg)
Two Detection ModesTwo Detection ModesDMD (Digital Methane Detection) Mode
• Used in most survey situations.• Silent until methane is detected.• Higher the tone, the higher the methane
concentration.
Pure Tones Mode• Continuous tone relative to methane
concentration levels.• Most effective up close to help verify low level
detections.
![Page 24: Remote Methane Leak Detector RMLD vs. Flame Ionization Paul D. Wehnert NYSEARCH](https://reader035.vdocuments.net/reader035/viewer/2022062321/56649e385503460f94b285a6/html5/thumbnails/24.jpg)
RMLD Overview: RMLD Overview: Parts and Functions Parts and Functions
Transceiver
Transceiver24
Green Spotter Laser * (approx 3” above IR laser)
Infrared (IR) Detector Laser(invisible beam)
Spotter Trigger Switch
*Caution: Don’t stare into beam or view directly with optical instruments.
Sighting Marking
Fiber Opticinside Cord
![Page 25: Remote Methane Leak Detector RMLD vs. Flame Ionization Paul D. Wehnert NYSEARCH](https://reader035.vdocuments.net/reader035/viewer/2022062321/56649e385503460f94b285a6/html5/thumbnails/25.jpg)
Laser SafetyLaser Safety• Infra-red Detector Laser
- Class I- Always on when instrument is on. This laser is
invisible.
• Green Spotter Laser- Class IIIa- Under the control of the operator- Same rating as pointer lasers commonly sold in
stores and used for business presentations- Safe when handled properly
![Page 26: Remote Methane Leak Detector RMLD vs. Flame Ionization Paul D. Wehnert NYSEARCH](https://reader035.vdocuments.net/reader035/viewer/2022062321/56649e385503460f94b285a6/html5/thumbnails/26.jpg)
Survey Techniques – Keep Survey Techniques – Keep Beam In Front Of You: 15 – 20 Beam In Front Of You: 15 – 20
FeetFeet
![Page 27: Remote Methane Leak Detector RMLD vs. Flame Ionization Paul D. Wehnert NYSEARCH](https://reader035.vdocuments.net/reader035/viewer/2022062321/56649e385503460f94b285a6/html5/thumbnails/27.jpg)
Greater Scanning Ability To Cover A Wide Area If Greater Scanning Ability To Cover A Wide Area If Meter / Service Is UnknownMeter / Service Is Unknown
![Page 28: Remote Methane Leak Detector RMLD vs. Flame Ionization Paul D. Wehnert NYSEARCH](https://reader035.vdocuments.net/reader035/viewer/2022062321/56649e385503460f94b285a6/html5/thumbnails/28.jpg)
RRMLDMLD Benefits To The Customer, Benefits To The Customer, Employee And CompanyEmployee And Company
• Less intrusion on property• Better customer relations• Help employee perform their job more
efficiently• Reduce cost and increase productivity
![Page 29: Remote Methane Leak Detector RMLD vs. Flame Ionization Paul D. Wehnert NYSEARCH](https://reader035.vdocuments.net/reader035/viewer/2022062321/56649e385503460f94b285a6/html5/thumbnails/29.jpg)
BenefitsBenefits
Reduce survey challenges:
• Dogs• Landscaping• Uncooperative Customers• Natural Disasters – Earth-
Quakes, Hurricanes, Floods
![Page 30: Remote Methane Leak Detector RMLD vs. Flame Ionization Paul D. Wehnert NYSEARCH](https://reader035.vdocuments.net/reader035/viewer/2022062321/56649e385503460f94b285a6/html5/thumbnails/30.jpg)
• Backyard main/services.
• Over or through fences / no access
• Enclosed Regulator stations
BenefitsBenefits
Reduce Survey challenges:
![Page 31: Remote Methane Leak Detector RMLD vs. Flame Ionization Paul D. Wehnert NYSEARCH](https://reader035.vdocuments.net/reader035/viewer/2022062321/56649e385503460f94b285a6/html5/thumbnails/31.jpg)
![Page 32: Remote Methane Leak Detector RMLD vs. Flame Ionization Paul D. Wehnert NYSEARCH](https://reader035.vdocuments.net/reader035/viewer/2022062321/56649e385503460f94b285a6/html5/thumbnails/32.jpg)
• Perform most surveys without physically walking service lines.
• Can scan both sides of the street.
• Safer to inspect busy street and intersections.
BenefitsBenefits
![Page 33: Remote Methane Leak Detector RMLD vs. Flame Ionization Paul D. Wehnert NYSEARCH](https://reader035.vdocuments.net/reader035/viewer/2022062321/56649e385503460f94b285a6/html5/thumbnails/33.jpg)
Compressor Stations:
• Quicker and more efficient inspection of multiple exposed piping in a stations yard.
BenefitsBenefits
![Page 34: Remote Methane Leak Detector RMLD vs. Flame Ionization Paul D. Wehnert NYSEARCH](https://reader035.vdocuments.net/reader035/viewer/2022062321/56649e385503460f94b285a6/html5/thumbnails/34.jpg)
BenefitsBenefits
More efficient survey of pipelines on bridges and overpasses
![Page 35: Remote Methane Leak Detector RMLD vs. Flame Ionization Paul D. Wehnert NYSEARCH](https://reader035.vdocuments.net/reader035/viewer/2022062321/56649e385503460f94b285a6/html5/thumbnails/35.jpg)
• Able to remotely check inside buildings or confined spaces for presence of methane.
• Intrinsic Safety
BenefitsBenefits
![Page 36: Remote Methane Leak Detector RMLD vs. Flame Ionization Paul D. Wehnert NYSEARCH](https://reader035.vdocuments.net/reader035/viewer/2022062321/56649e385503460f94b285a6/html5/thumbnails/36.jpg)
Benefits – Emergency SituationsBenefits – Emergency Situations
![Page 37: Remote Methane Leak Detector RMLD vs. Flame Ionization Paul D. Wehnert NYSEARCH](https://reader035.vdocuments.net/reader035/viewer/2022062321/56649e385503460f94b285a6/html5/thumbnails/37.jpg)
Benefits – Emergency SituationsBenefits – Emergency Situations
![Page 38: Remote Methane Leak Detector RMLD vs. Flame Ionization Paul D. Wehnert NYSEARCH](https://reader035.vdocuments.net/reader035/viewer/2022062321/56649e385503460f94b285a6/html5/thumbnails/38.jpg)
BenefitsBenefits
![Page 39: Remote Methane Leak Detector RMLD vs. Flame Ionization Paul D. Wehnert NYSEARCH](https://reader035.vdocuments.net/reader035/viewer/2022062321/56649e385503460f94b285a6/html5/thumbnails/39.jpg)
BenefitsBenefits
![Page 40: Remote Methane Leak Detector RMLD vs. Flame Ionization Paul D. Wehnert NYSEARCH](https://reader035.vdocuments.net/reader035/viewer/2022062321/56649e385503460f94b285a6/html5/thumbnails/40.jpg)
Benefits Benefits
• Wider area of search due to sweeping of the beam- Significant advantage to detect leaks away from
the pipe Scanning technique verses probing technique
• Productivity savings 20% to 40% for most utilities
• Rapid warm-up• Built in self test and calibration
- Verifies operation and adjusts laser wavelength for maximum sensitivity
![Page 41: Remote Methane Leak Detector RMLD vs. Flame Ionization Paul D. Wehnert NYSEARCH](https://reader035.vdocuments.net/reader035/viewer/2022062321/56649e385503460f94b285a6/html5/thumbnails/41.jpg)
Questions?Questions?