remotely programmable and controllable alarm system · tecnoalarm, sntp and mail server tecnoalarm...
TRANSCRIPT
2
Standard equipment
Expansions
Control modes
Automation
Ports
Software options/Compatibility with monitoring software
TP10-42• Management of max. 42 hard-wired zones• Management of max. 42 wireless zones (used
alternatively to the hard-wired zones)• 1 tamper input• 4 zone inputs for conventional detectors• 1 Sensor Bus port for 6 RSC® peripheral devices• 1 RS485 port for conventional peripheral devices• 1 Siren Bus port for 4 RSC® sirens• 1 alarm output for indoor siren• 1 alarm output for outdoor siren• 6 programmable logic outputs• On-board PSTN interface: 8 channels with 2 telephone
numbers each• Event notifi cation in the formats: speech, SMS, Ring,
DTMF, FSK and data• Communication vectors: PSTN (on-board), GSM-GPRS,
GSM and TCP/IP (optional)• GSM network cell scanner function• Jammer detector function• Voice synthesis• Management of multiuser systems with common zones• Management of the telematic services DDNS
Tecnoalarm, SNTP and Mail Server Tecnoalarm• 8 programs• 8 remote controls
• 8 timers• 6 access periods• 8 cyclic timers• Quadrennial or perpetual calendar• Management of biometric fi nger print and RFID card
readers• 122 access codes• 100 fi nger prints• 100 transponders/RFID cards• 80 wireless keys• Digital control of the radio range and interferences• Programmable coincidence function• Event buffer with a capacity of 7600 events• 14.4V power supply output for battery recharge• Battery test with automatic disconnection in case of
failure• 3A linear power supply
CPU ESP4-20SPEED8 STD
SPEED4
SPEED4-14OC
SPEED8
SPEEDALM8 PL
SPEED4 PLUS
SPEED8 PLUS
SPEEDALM8 PLUS
TP4-20ATE2 ATE2 ATE2
C C D
TP4-20 GSMATE2 ATE2 ATE2
C C D
TP8-28ATE2 ATE4 ATE2
A B C
TP8-28 GSMATE4 ATE4 ATE2
A B C
TP10-42ATE2 ATE4 ATE4 ATE2
A A A
TP8-88ATE2 ATE4 ATE4 ATE2
A A A
TP20-440ATE2 ATE4 ATE4 ATE2
A A A
TP8-88ATE2 ATE4 ATE4 ATE2
A A A
TP20-440ATE2 ATE4 ATE4 ATE2
A A A
TP4-20ATE2 ATE2 ATE2
C C D
TP4-20 GSMATE2 ATE2 ATE2
C C D
TP8-28ATE2 ATE4 ATE2
A B C
TP8-28 GSMATE4 ATE4 ATE2
A B C
ATEATE22 ATEATE44 ATEATE44 ATEATE22
AAA BBB CCC
TP10-42ATEATEATE222 ATEATEATE444 ATEATEATE444 ATEATEATE222
AAAA AAAA AAAA
CC
UTS V4 4 - 1/4
UTS V8 8 - 1/4
UTS E 24 8 1/4
3
Inputs
CONVENTIONAL* 44
84 4 8 8 4 - -
ZONE BUS - -
SENSOR BUS 6 - - - - - - 4 8 8
* The following contact types can be programmed: NC (normally closed), NO (normally open), BIL (end-of-line resistor), B24 (double end-of-line resistor). The following fi lters can be programmed: time, pulse count or inertia.
L 398mm
H 309mm
H 90mm
D 108mm
A: excellent - B: good - C: satisfactory - D: not implemented
Technical evaluation
index
Serial ports Communication vectors Videoalarm/Telematic Services
Cameras CamerasRecording RecordingViewing Viewing
4
1
TECNOCELL-PRO PL
8
APR FINGER-CARDTP SKN PROX K6N DIGITEX APR CARD APR FINGER
8
LCDPROX1 LCD300/S
UTS V8 UTS V4 UTS C
+SRA- SIR
- OUT1- OUT2+ OUT3+ OUT4
--++
ESP LAN
ESP GSM-GPRS
6
SIREN BUS
SENSOR BUS
SERIAL BUS
SRASRINTOUT2OUT1
SIREN BUS
SPEED ALM8 PLUS
OUT2OUT1
SPEED 8 PLUS
OUT1
SPEED 4 PLUS
+ SRA+ SR
- OUT1- OUT2
SIREN BUS
TAPS-8 BUS
SAEL 2010 BUS SIRTEC BUS
ETHERNET PORT
UTS 4.3 PROX
ESP 4-20
PROG INTERFACE
4
The label indicates the number of connectable devices per type.
POWER SUPPLIES
CONSOLES
BUS SIRENS
AUXILIARY CONTROL UNITSTELEPHONE
COMMUNICATORS
3 243
IP CAMERAUTS E
10
SRASRINTOUT2OUT1
SPEED ALM8 PL
OUT2OUT1
SPEED 8
OUT1
SPEED 4
OUT1 - 14
SPEED 4-14OC
1
SPEED 8 STD
16
ESP 8RP ESP 8RSP ESP 4RS ESP32-OCN SINOTTICO 32N
1 2 3 4 5 6 7 8
2
RX300/433868 RTX200/433868
2+242
142
RTX500 BWL RTX500S BWL
1082
N
Tecn
oala
rm S
erve
r
PROG USB PROG32
5
OUTPUT EXPANSIONS
WIRELESS ASYNC@WLUse alternatively to RTX500 BWL - RTX500S BWL
WIRELESS SYNC@BWLUse alternatively to RX300/433868 - RTX200/433868
TELEMATIC SERVICES
System confi guration
A B C
A B C
A B C
AB C
6
Internal expansions and interfaces
ESP4-20
ESP GSM-GPRS
ESP LAN
Expansion module with 4 parallel inputs for the connection of conventional detectors and Zone Bus detectors (only the fi rst two inputs)
Interface for the connection of the control panel with the GSM or GSM-GPRS networkThe interface allows to use the GSM or GSM-GPRS network as communication vector.
Ethernet-InterfaceThe interface implements the IP vector and permits remote management with TCP/IP.
Item no. F127TP420ESP
Item no. F127ESPGSMGPRS
Item no. F127ESPLAN
Mounting position
Mounting position
Mounting position
MOUNTING POSITIONS
Approved for use
with certifi ed
control panels
Approved for use
with certifi ed
control panels
Approved for use
with certifi ed
control panels
7
GSM ANTENNA EXTENSION
4m extension cord for the connection of the antenna to the GSM-GPRS module
Item no. C126PROLANTENNA
TP10-42 - Accessories
OPTIONS
Option Item no.
ADVANCEDPROGRAMMING F127T42/AV Advanced programming software module
VECTORS
Vector Device Class DDNS MAIL APP RDV® SMSRemotecontrols
Remotemanagement
Monitoring
PSTN ON-BOARD ATE2 ✓ ✓ ✓ ✓
GSM-GPRS* ESP GSM-GPRS ATE2/4 ✓ ✓ ✓ ✓ ✓
GSM-EXT* TECNOCELL PRO PL ATE2 ✓ ✓ ✓
IP* ESP LAN ATE2/4 ✓ ✓ ✓ ✓ ✓
* The vectors GSM-GPRS, GSM-EXT and IP are optional and require the installation of internal and external interfaces.Class - The class defi nes the performance criteria of the alarm transmission equipment (ATE) for alarm notifi cation. In compliance with the valid standards, the criteria of performance are divided into six classes from ATE1 to ATE6. The vectors are classifi ed as ATE2 or ATE4 according to the communication protocols used. The class ATE4 requires the use of encrypted protocols. The IP vector has been certifi ed class ATE4 on the basis of internal tests executed by Tecnoalarm.
MODELS
Model Item no.
TP10-42 F101T42-IT ✓ Optional Optional Optional 3A ✓
SMS
c/Vapor 18 (Pol. Ind. El Regas)08850 Gavá - Barcelona (España)tel. [email protected]
495, Rue Antoine Pinay - 69740 Genas Lyon (France)tél. +33478406525 - fax +33478406746tecnoalarm.france@tecnoalarm.comwww.tecnoalarm.comAgence de Paris: 125, Rue Louis Roche 92230 Gennevilliers
Via Ciriè, 38 - 10099 - San Mauro T.se Torino (Italy)tel. +390112235410 - fax [email protected] - www.tecnoalarm.com
Systems TP10-42 - Technical and functional specifi cations
Zones
Total logic zones 42
CPU hard-wired zones4 conventional
6 Sensor Bus
Total hard-wired zones 42
Total wireless zones 42
OutputsCPU outputs 6 programmable
Sirens 8
Systemfeatures
RS485 serial bus 3
Voice synthesis ✓
Event buffer capacity 7,600 events
Programs andaccess
management
Programs 8
Codes 122
Finger prints 100
Transponders/RFID 100
Wireless keys 80
Automation
Timers 8
Access periods 6
CalendarQuadrennial or
perpetual
Remote controls 8
Cyclic timers 8
TCS (test call with TCP/IP) ✓
Telephonesection
Channels 8
PSTN vector On-board
GSM-GPRS vector (optional) ESP GSM-GPRS
GSM vector (optional) TECNOCELL-PRO PL
IP vector (optional) ESP LAN
Transmittable events 157
Telephone numbers/IP addresses
2 per channel (max. 24 digits)
Call event queue 32
Communication protocols 216
Telematicservices
DDNS Tecnoalarm ✓
Mail Server Tecnoalarm ✓
SNTP ✓
VideoalarmCCTV ✓
IP ✓
Serialexpansions
Hard-wired input expansions 10
Wireless expansions 2
Consoles 8
Auxiliary control units 8
Output expansions 16
GSM telephone communicator 1
Bus sirens 4
Wireless sirens 2
Wireless consoles 2 (ASYNC@WL)
Advancedprogramming
Actions 1,024
Timers 512
Counters 128
Telephone index 48 numbers
Reserved output expansions 4
Accessorymanagement
App (iPhone + Android) ✓
Printer management ✓
Electricalspecifi cations
Operating voltage 230V AC +/-10% 50Hz
CPU board consumption 150mA @ 13.8V DC
Power supply 3A @ 14.4V DC
Battery 1x 12V/12Ah
Physicalspecifi cations
Environmental class II
Casing Metal
Dimensions (L x H x D) (w/o antenna)
398 x 309 x 108mm
Antenna height 90mm
Weight (w/o battery) 4.2kg
Operating temperature -10°C…+55°C
Humidity (w/o condensation) 93%
Conformity Directive R&TTE 1999/05/EC