repairs to the search and rescue training facility in jericho€¦ · the palestinian search and...

14
Jan 31, 2018 Repairs to the Search and Rescue Training Facility in Jericho Scope of Work & Estimated Budget For Needed Repairs January 2018

Upload: others

Post on 02-Aug-2020

2 views

Category:

Documents


0 download

TRANSCRIPT

Page 1: Repairs to the Search and Rescue Training Facility in Jericho€¦ · The Palestinian Search and Rescue (SAR) Center was built in 2010 and serves as the only fire training facility

Jan 31, 2018

Repairs to the Search and Rescue Training Facility in Jericho

Scope of Work & Estimated Budget

For Needed Repairs

January 2018

Page 2: Repairs to the Search and Rescue Training Facility in Jericho€¦ · The Palestinian Search and Rescue (SAR) Center was built in 2010 and serves as the only fire training facility

Statement of Work

Repairs to the Search and Rescue Fire Training Center

INL/Palestinian Civil Defense Fire Service Training

Period of Performance

The period of performance for this action will be February to May, 2018.

Needs Justification

The Bureau of International and Law Enforcement affairs (INL) has provided assistance

to the Palestinian Civil Defense (PCD) since 2010, in the form of advisory mentoring,

training, supplies, equipment and infrastructure.

The PCD was officially authorized to deliver emergency services in 1994. Four years

later the General Law for Civil Defense authorized the PCD to provide public protection

services and identified 13 civil defense functions. Today the West Bank PCD has

responsibility for providing fire and other emergency response services to an area the size

of Delaware and for a population 1.6 to 2.5 million people (no accurate census available)

with the exception of two cities, Hebron and Nablus who manage their own fire

departments.

The purpose for the repair project is to provide the PCD with a fire/rescue training

facility in the West Bank that provides the PCD firefighters and instructors with live fire

training to simulate actual fire ground conditions.

To successfully perform rescues and gain control over fire and other emergencies, the

PCD firefighters must learn to safely operate specialized equipment, recognize hazards in

order to select the best strategy with minimal risks and work as a team within the incident

command system. These skills are acquired by completing courses at a specially

designed fire training academy from professionals who have mastered the skills. A fire

training facility must be designed to challenge trainees with realistic fire ground

conditions while insuring safety measures are included to prevent injuries.

The Palestinian Search and Rescue (SAR) Center was built in 2010 and serves as the only

fire training facility in the West Bank. Although space is limited, the site offers the PCD

with a viable, local option for training their 1,178 firefighters and approximately 3,000

volunteers. Since the SAR was built, the building has fallen into disrepair. INL, at the

request of the PCD, supported a renovation project in 2017 that repaired the kitchen,

remodeled two classrooms, added solar panels, a water tank and a fire building built from

metal containers. While completing the repairs from July-October 2017, both INL and

the PCD identified the need for additional repairs to the facility. The additional repairs

are not extensive but are critical for training and lodging for the students over the length

of the courses.

Page 3: Repairs to the Search and Rescue Training Facility in Jericho€¦ · The Palestinian Search and Rescue (SAR) Center was built in 2010 and serves as the only fire training facility

After conducting a thorough review of the project requirements; the following

repairs are needed:

1. Repair and/or Replace 6 shower fixtures

Provide commercial grade shower fixtures.

Provide exposed wall mount shower including rainfall head, handheld shower and

dual cross handles.

2. Repair and/or Replace 8 faucets to bathroom sinks

Wall-Mounted faucet

Rigid/swivel gooseneck spout

Commercial grade faucet fixtures

3. Repair and/or Replace 6 toilet tanks

Provide heavy duty grade fixtures

4. Repair and/or Replace ceiling light fixtures

To provide 35 outdoor ceiling lighting fixtures

Heavy duty ceiling lights to withstand high ambient temperatures

Replace 10 wall switches

Replace 30 ceiling light fixtures in dorms and classrooms

5. Repair and/or Replace septic system

Provide an assessment of facility’s needs and current septic system

Provide proposal to replace or repair septic system

Provide design that includes tank, drain pipes and leech field

6. Paint interior and exterior of two story building

Repair damaged walls and ceilings

Paint Poly-cide Paint for ceiling

Emulsion and oil paint for walls

7. Repair the existing internet system

Replace and install business router

Upgrade network cables

ITEM #1

Page 4: Repairs to the Search and Rescue Training Facility in Jericho€¦ · The Palestinian Search and Rescue (SAR) Center was built in 2010 and serves as the only fire training facility

Item Description: Shower faucets Quantity: 8

Replace shower faucets on

first and second floor

Page 5: Repairs to the Search and Rescue Training Facility in Jericho€¦ · The Palestinian Search and Rescue (SAR) Center was built in 2010 and serves as the only fire training facility

ITEM #1

Item Description: Shower faucets

Quantity: 8

Mandatory Specifications:

Commercial grade

Wall-Mounted faucet

Rigid/swivel gooseneck spout

Dual Knobs Mixer Rainfall Shower Set with

Handheld Spray Brushed Nickel

Faucet Material: Brass

Top Shower Material: Brass

Spray Material: Brass

Hole center(hot and cold water) distance

on the wall:15cm (6")

Initials Date

INL PM, Larry

Damrell

PCD representative

Page 6: Repairs to the Search and Rescue Training Facility in Jericho€¦ · The Palestinian Search and Rescue (SAR) Center was built in 2010 and serves as the only fire training facility

ITEM #2 Item Description: Faucets to sinks Quantity: 8

Replace faucets over sinks

on first and second floor

Page 7: Repairs to the Search and Rescue Training Facility in Jericho€¦ · The Palestinian Search and Rescue (SAR) Center was built in 2010 and serves as the only fire training facility

ITEM #2 Item Description: Faucets to sinks Quantity: 8

Mandatory Specifications:

Faucets to bathroom sinks

Commercial grade

Wall-Mounted faucet

Rigid/swivel gooseneck spout

Is a “like” item allowed: Yes

Initials Date

INL PM, Larry Damrell

PCD representative

Page 8: Repairs to the Search and Rescue Training Facility in Jericho€¦ · The Palestinian Search and Rescue (SAR) Center was built in 2010 and serves as the only fire training facility

ITEM #3

Item Description: Repair and/or replace toilet tanks

Quantity: 6 Mandatory Specifications:

Repair leaking tanks and connecting water lines

Replace defective parts with heavy duty replacement parts

Is a “like” item allowed: Yes

Initials Date

INL PM, Larry Damrell

PCD representative

Page 9: Repairs to the Search and Rescue Training Facility in Jericho€¦ · The Palestinian Search and Rescue (SAR) Center was built in 2010 and serves as the only fire training facility

ITEM #4 Item Description: Repair and/or Replace ceiling light and switch fixtures Quantity: 6 Mandatory Specifications:

Provide 35 outdoor ceiling lighting fixtures

Heavy duty ceiling lights to withstand high ambient temperatures

Replace 10 wall switches

Replace 30 ceiling light fixtures in dorms and classrooms

Repair existing electrical board

Contractor must provide independent inspection by licensed electrical engineer

Initials Date

INL PM, Larry Damrell

PCD representative

Outside light switch Outside ceiling light

Page 10: Repairs to the Search and Rescue Training Facility in Jericho€¦ · The Palestinian Search and Rescue (SAR) Center was built in 2010 and serves as the only fire training facility

ITEM #5 Item Description: Repair septic system Quantity: 1 Mandatory Specifications:

Provide an assessment of facility’s needs and current septic system

Provide proposal to replace or repair septic system

Provide design that includes tank, drain pipes and leech field

In calculating septic system, the training center has approximately 18 toilets and

may have a maximum of 60 persons on site

Initials Date

INL PM, Larry Damrell

PCD representative

Page 11: Repairs to the Search and Rescue Training Facility in Jericho€¦ · The Palestinian Search and Rescue (SAR) Center was built in 2010 and serves as the only fire training facility
Page 12: Repairs to the Search and Rescue Training Facility in Jericho€¦ · The Palestinian Search and Rescue (SAR) Center was built in 2010 and serves as the only fire training facility

ITEM #6

Item Description: Paint interior and exterior of two story building

Quantity: 1 Mandatory Specifications:

Paint interior and exterior walls same color (first and second floor)

Scrape all lose paint

Prime all surfaces that show substrate

Repair damaged walls and ceilings

Prime all exposed metal with zinc oxide primer

Paint metal surfaces with anti-rust primer and paint

Paint Poly-cide Paint for ceiling

Emulsion and oil paint for walls

Paint multilink door and steel protections of windows

Paint external red columns of the building

Initials Date

INL PM, Larry Damrell

PCD representative

Page 13: Repairs to the Search and Rescue Training Facility in Jericho€¦ · The Palestinian Search and Rescue (SAR) Center was built in 2010 and serves as the only fire training facility

ITEM #7

Item Description: Repair existing internet system

Quantity: 1

Mandatory Specifications:

Replace and install business router

o Device Type - 8-port switch (integrated)

o Data Link Protocol - Ethernet, Fast Ethernet, Gigabit Ethernet, IEEE

802.11b, IEEE 802.11a, IEEE 802.11g, IEEE 802.11n, IEEE 802.11ac

o Frequency Band - 2.4 GHz (1 band) / 5 GHz (2 bands)

o Data Transfer Rate - 5.3 Gbps

o Encryption Algorithm - 128-bit WEP, 64-bit WEP, WPA, WPA2, 128-bit

AES, WPA2-Enterprise

o Features - Wi-Fi Protected Setup (WPS), reset button, 4T4R MIMO

technology, beamforming technology, Tri-Band

o Processor 1.4 GHz Power Device

o Voltage Required - AC 120/230 V (50/60 Hz)

Upgrade network cables

Is a “like” item allowed: Yes

Initials Date

INL PM, Larry Damrell

PCD representative

Page 14: Repairs to the Search and Rescue Training Facility in Jericho€¦ · The Palestinian Search and Rescue (SAR) Center was built in 2010 and serves as the only fire training facility

Palestinian Authority Palestinian Civil Defense

Search and Rescue Fire Training Facility in Jericho