report no.: hz19050020b - green creative€¦ · model : 8t8/3f/840/dir/rc electrical ratings : 1...

18

Upload: others

Post on 19-Oct-2020

2 views

Category:

Documents


0 download

TRANSCRIPT

Page 2: Report No.: HZ19050020b - GREEN CREATIVE€¦ · Model : 8T8/3F/840/DIR/RC Electrical Ratings : 1 20-277V, 60Hz, 8W ... Test was conducted without a dimmer in the circuit. The stabilization

Report No.: HZ19050020b

Prepared by: Leading Testing Laboratories Page 2 of 18

3rd Floor, Bld. 2, NO. 96 Longchuanwu Rd Qianjiang Economy Dev. Zone, YuhangDist,

Hangzhou, Zhejiang Province, China 311100

Tel: +86 571 86376106 www.ledtestlab.com

TEST SUMMARY

Sample Tested: 8T8/3F/840/DIR/RC

Luminous Efficacy

(Lumens /Watt)

Total Luminous Flux

(Lumens)

Power

(Watts) Power Factor

131.5 1424.0 10.83 0.9886

CCT

(K) CRI

Stabilization Time

(Light & Power)

4062 82.2 60

Table 1: Executive Data Summary

Note: The above results are recorded/ derived from measurements made using an Integrating Sphere.

Test specifications:

Date of Receipt : May 16, 2019

Date of Test : May 21, 2019

Test item : Total Luminous Flux, Luminous Distribution Intensity, Luminous Efficacy,

Correlated Color Temperature, Color Rendering Index, Chromaticity

Coordinate, Electrical parameters

Reference Standard : IESNA LM-79-2008 Approved Method for the Electrical and Photometric

Measurements of Solid-State Lighting Products

ANSI/IES TM-30-18 IES Method for Evaluating Light Source Color

Rendition

Page 3: Report No.: HZ19050020b - GREEN CREATIVE€¦ · Model : 8T8/3F/840/DIR/RC Electrical Ratings : 1 20-277V, 60Hz, 8W ... Test was conducted without a dimmer in the circuit. The stabilization

Report No.: HZ19050020b

Prepared by: Leading Testing Laboratories Page 3 of 18

3rd Floor, Bld. 2, NO. 96 Longchuanwu Rd Qianjiang Economy Dev. Zone, YuhangDist,

Hangzhou, Zhejiang Province, China 311100

Tel: +86 571 86376106 www.ledtestlab.com

TABLE OF CONTENT

LM-79-08 TEST REPORT .................................................................................................................................... 1

TEST SUMMARY ................................................................................................................................................. 2

SAMPLE PHOTO .................................................................................................................................................. 4

TEST RESULTS .................................................................................................................................................... 5

Sphere-Spectroradiometer Method ..................................................................................................................... 5

Goniophotometer Method .................................................................................................................................. 6

Spectral Power Distribution - Sphere Spectroradiometer Method ..................................................................... 7

Chromaticity Diagram - Sphere Spectroradiometer Method .............................................................................. 8

Nominal CCT Quadrangles – Sphere Spectroradiometer Method ..................................................................... 9

Color Rendition Report – Sphere Spectroradiometer Method ......................................................................... 10

Zonal Lumen Tabulation- Goniophotometer Method ...................................................................................... 11

Illuminance Plots- Goniophotometer Method .................................................................................................. 12

Luminous Intensity Distribution Plots- Goniophotometer Method .................................................................. 13

Luminous Intensity Data- Goniophotometer Method ...................................................................................... 14

EQUIPMENT LIST ............................................................................................................................................. 16

TEST METHODS ................................................................................................................................................ 16

Seasoning of SSL Product ................................................................................................................................ 16

Sphere-Spectroradiometer Method- Photometric and Electrical Measurements .............................................. 16

Goniophotometer Method ................................................................................................................................ 17

Photometric and Electrical Measurements ................................................................................................... 17

Color Characteristics Measurements ............................................................................................................ 17

Color Spatial Uniformity ............................................................................................................................. 17

Page 4: Report No.: HZ19050020b - GREEN CREATIVE€¦ · Model : 8T8/3F/840/DIR/RC Electrical Ratings : 1 20-277V, 60Hz, 8W ... Test was conducted without a dimmer in the circuit. The stabilization

Report No.: HZ19050020b

Prepared by: Leading Testing Laboratories Page 4 of 18

3rd Floor, Bld. 2, NO. 96 Longchuanwu Rd Qianjiang Economy Dev. Zone, YuhangDist,

Hangzhou, Zhejiang Province, China 311100

Tel: +86 571 86376106 www.ledtestlab.com

SAMPLE PHOTO

Figure 1- Overview of the sample

Equipment Under Test(EUT)

Name : LED Tube

Model : 8T8/3F/840/DIR/RC

Electrical Ratings : 120-277V, 60Hz, 8W

Product Description : 4000K

LED Tubes supplied by a high frequency fluorescent lamp ballast:

IOPA-1P32-N

Manufacturer : GREEN CREATIVE LTD

Address : 756 North Zhongshan Rd., Unit B301 Zhabei District, Shanghai

Page 5: Report No.: HZ19050020b - GREEN CREATIVE€¦ · Model : 8T8/3F/840/DIR/RC Electrical Ratings : 1 20-277V, 60Hz, 8W ... Test was conducted without a dimmer in the circuit. The stabilization

Report No.: HZ19050020b

Prepared by: Leading Testing Laboratories Page 5 of 18

3rd Floor, Bld. 2, NO. 96 Longchuanwu Rd Qianjiang Economy Dev. Zone, YuhangDist,

Hangzhou, Zhejiang Province, China 311100

Tel: +86 571 86376106 www.ledtestlab.com

TEST RESULTS

Test ambient temperature was 25.0℃.

Base orientation was light down. Test was conducted without a dimmer in the circuit.

The stabilization time of the sample was 60 minutes, and the total operating time including stabilization was 65

minutes.

Sphere-Spectroradiometer Method

Parameter Result

Special Color

Rendering

Indices

Test Voltage (V) 120.0 277.0 R1 80.2

Voltage frequency (Hz) 60 60 R2 88.4

Test Current (A) 0.091 0.045 R3 94.7

Power Factor 0.9886 0.8990 R4 81.1

Test Power (W) 10.83 11.08 R5 80.2

THD A% 11.24 18.37 R6 83.9

Luminous Efficacy (lm/W) 131.5 128.5 R7 86

Total Luminous Flux (lm) 1424.0 1424.0 R8 63.4

Color Rendering Index (CRI) 82.2 R9 4.2

R9 4.2 R10 72.6

Correlated Color Temperature (CCT)(K) 4062 R11 80

Chromaticity Chroma x 0.3789 R12 59.6

Chromaticity Chroma y 0.3798 R13 82.2

Chromaticity Chroma u 0.2229 R14 97.2

Chromaticity Chroma v 0.3351

Duv 0.0013

Chromaticity Chroma u ’ 0.2229

Chromaticity Chroma v’ 0.5027

Table 2: Test data per Sphere-Spectroradiometer Method

Note: According to CIE 1976 (u’,v’) diagram, u’ = u = 4x/(-2x+12y+3), v’ = 3v/2 = 9y/(-2x+12y+3).

Page 6: Report No.: HZ19050020b - GREEN CREATIVE€¦ · Model : 8T8/3F/840/DIR/RC Electrical Ratings : 1 20-277V, 60Hz, 8W ... Test was conducted without a dimmer in the circuit. The stabilization

Report No.: HZ19050020b

Prepared by: Leading Testing Laboratories Page 6 of 18

3rd Floor, Bld. 2, NO. 96 Longchuanwu Rd Qianjiang Economy Dev. Zone, YuhangDist,

Hangzhou, Zhejiang Province, China 311100

Tel: +86 571 86376106 www.ledtestlab.com

Goniophotometer Method

Test ambient temperature was 25.2℃.

The photometric distance is 30 m.

Luminous data was taken at 0.5°vertical intervals and 10°horizontal intervals.

Parameter Result

Test Voltage (V) 120.0

Voltage frequency (Hz) 60

Test Current (A) 0.092

Power Factor 0.9893

Power (W) 10.86

Luminous Efficacy (lm/W) 129.2

Total Luminous Flux (lm) 1403.1

Beam Angle (°) 114.0 (0o-180

o) / 237.4 (90

o-270

o)

Center Beam Candle Power (cd) 220

Maximum Beam Candle Power (cd) 219.7 (At: C=270.0, Gamma=3.0)

Spacing Criteria 1.26 (0o-180

o) / 1.48 (90

o-270

o)

Zonal Lumens in the 0°-60°Zone 41.31%

Zonal Lumens in the 60°-90°Zone 26.99%

Zonal Lumens in the 90°-120°Zone 18.19%

Zonal Lumens in the 120°-180°Zone 13.51%

Table 3: Test data per Goniophotometer Method

Page 7: Report No.: HZ19050020b - GREEN CREATIVE€¦ · Model : 8T8/3F/840/DIR/RC Electrical Ratings : 1 20-277V, 60Hz, 8W ... Test was conducted without a dimmer in the circuit. The stabilization

Report No.: HZ19050020b

Prepared by: Leading Testing Laboratories Page 7 of 18

3rd Floor, Bld. 2, NO. 96 Longchuanwu Rd Qianjiang Economy Dev. Zone, YuhangDist,

Hangzhou, Zhejiang Province, China 311100

Tel: +86 571 86376106 www.ledtestlab.com

Spectral Power Distribution - Sphere Spectroradiometer Method

Chart 1: Spectral Power Distribution

Spectral Distribution over Visible Wavelength

WL(nm) Radiant(Watts) WL(nm) Radiant(Watts) WL(nm) Radiant(Watts) WL(nm) Radiant(Watts)

380 2.49E-04 485 7.57E-03 590 2.45E-02 695 3.49E-03

385 2.47E-04 490 8.51E-03 595 2.44E-02 700 2.99E-03

390 2.70E-04 495 1.00E-02 600 2.42E-02 705 2.57E-03

395 2.97E-04 500 1.18E-02 605 2.38E-02 710 2.19E-03

400 3.26E-04 505 1.34E-02 610 2.30E-02 715 1.87E-03

405 3.86E-04 510 1.48E-02 615 2.20E-02 720 1.60E-03

410 5.13E-04 515 1.59E-02 620 2.08E-02 725 1.38E-03

415 7.44E-04 520 1.67E-02 625 1.95E-02 730 1.18E-03

420 1.17E-03 525 1.73E-02 630 1.81E-02 735 1.00E-03

425 2.01E-03 530 1.79E-02 635 1.65E-02 740 8.59E-04

430 3.49E-03 535 1.83E-02 640 1.51E-02 745 7.32E-04

435 6.09E-03 540 1.89E-02 645 1.35E-02 750 6.27E-04

440 1.07E-02 545 1.94E-02 650 1.21E-02 755 5.42E-04

445 1.97E-02 550 1.99E-02 655 1.07E-02 760 4.70E-04

450 2.87E-02 555 2.05E-02 660 9.52E-03 765 4.04E-04

455 2.43E-02 560 2.12E-02 665 8.31E-03 770 3.44E-04

460 1.60E-02 565 2.18E-02 670 7.26E-03 775 3.00E-04

465 1.29E-02 570 2.26E-02 675 6.31E-03 780 2.58E-04

470 1.00E-02 575 2.32E-02 680 5.47E-03

475 7.54E-03 580 2.38E-02 685 4.72E-03

480 7.09E-03 585 2.43E-02 690 4.07E-03

Table 4: Spectral Power Distribution Numerical Data per Sphere - Spectroradiometer Method

Page 8: Report No.: HZ19050020b - GREEN CREATIVE€¦ · Model : 8T8/3F/840/DIR/RC Electrical Ratings : 1 20-277V, 60Hz, 8W ... Test was conducted without a dimmer in the circuit. The stabilization

Report No.: HZ19050020b

Prepared by: Leading Testing Laboratories Page 8 of 18

3rd Floor, Bld. 2, NO. 96 Longchuanwu Rd Qianjiang Economy Dev. Zone, YuhangDist,

Hangzhou, Zhejiang Province, China 311100

Tel: +86 571 86376106 www.ledtestlab.com

Chromaticity Diagram - Sphere Spectroradiometer Method

Tristimulus values(x, y): (0.3789, 0.3798)

Chart 2: Chromaticity Diagram per Sphere - Spectroradiometer Method

Note: The location on the diagram of the tristimulus coordinates are indicated by the blue diamond.

Page 9: Report No.: HZ19050020b - GREEN CREATIVE€¦ · Model : 8T8/3F/840/DIR/RC Electrical Ratings : 1 20-277V, 60Hz, 8W ... Test was conducted without a dimmer in the circuit. The stabilization

Report No.: HZ19050020b

Prepared by: Leading Testing Laboratories Page 9 of 18

3rd Floor, Bld. 2, NO. 96 Longchuanwu Rd Qianjiang Economy Dev. Zone, YuhangDist,

Hangzhou, Zhejiang Province, China 311100

Tel: +86 571 86376106 www.ledtestlab.com

Nominal CCT Quadrangles – Sphere Spectroradiometer Method

Chart 3: Plot of Lamp x/y coordinates on CIE 1931 Chromaticity Diagram

Page 10: Report No.: HZ19050020b - GREEN CREATIVE€¦ · Model : 8T8/3F/840/DIR/RC Electrical Ratings : 1 20-277V, 60Hz, 8W ... Test was conducted without a dimmer in the circuit. The stabilization

Report No.: HZ19050020b

Prepared by: Leading Testing Laboratories Page 10 of 18

3rd Floor, Bld. 2, NO. 96 Longchuanwu Rd Qianjiang Economy Dev. Zone, YuhangDist,

Hangzhou, Zhejiang Province, China 311100

Tel: +86 571 86376106 www.ledtestlab.com

Color Rendition Report – Sphere Spectroradiometer Method

Chart 4: Full Report Created with the IES TM-30 Calculator

Note: The values in this diagram might be a little different from the values in Table 2 due to rounding.

x

y

u '

v '

Notes: This is a recommended method fordisplaying ANSI/IES TM-30-18information.

0.3789

0.3798

0.2229

0.5027

-20%

+20%

1

2

3

45

16

6

7

8

9

10 15

11

12 13

14 Duv

84

CCT

95

0.0019

RgRf

4065 K

0

10

20

30

40

50

60

70

80

90

100

CES

01

CES

04

CES

07

CES

10

CES

13

CES

16

CES

19

CES

22

CES

25

CES

28

CES

31

CES

34

CES

37

CES

40

CES

43

CES

46

CES

49

CES

52

CES

55

CES

58

CES

61

CES

64

CES

67

CES

70

CES

73

CES

76

CES

79

CES

82

CES

85

CES

88

CES

91

CES

94

CES

97

Co

lor

Sa

mp

le F

ide

lity

(Rf,

CE

Si)

-0.0

1

0.0

6

0.1

1

0.0

7

0.0

4

-0.0

2

-0.0

3

-0.0

1

0.0

6

0.1

3

0.1

5

0.0

7

-0.0

6

-0.0

7

-0.1

7

-0.1

3

-0.5

-0.4

-0.3

-0.2

-0.1

0.0

0.1

0.2

0.3

0.4

0.5

Loca

l Hu

e S

hif

t (R

hs,

hj)

79 8378

88 9094 91 89 86

77 7783 86 86

77 77

0102030405060708090

100

1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16

Loca

l Col

or F

idel

ity

(Rf,

hj)

Hue-Angle Bin (j)

-12

% -8% -4

% 0%

0% 2%

-4%

-6%

-7%

-7%

2% 6

% 8%

4%

-1%

-6%

-40%

-30%

-20%

-10%

0%

10%

20%

30%

40%

Loca

l Ch

rom

a Sh

ift

(Rcs

,hj)

380 430 480 530 580 630 680 730 780

Ra

dia

nt

Po

we

r

(Eq

ua

l Lu

min

ou

s F

Lux)

Wavelength (nm)

Reference Test

Page 11: Report No.: HZ19050020b - GREEN CREATIVE€¦ · Model : 8T8/3F/840/DIR/RC Electrical Ratings : 1 20-277V, 60Hz, 8W ... Test was conducted without a dimmer in the circuit. The stabilization

Report No.: HZ19050020b

Prepared by: Leading Testing Laboratories Page 11 of 18

3rd Floor, Bld. 2, NO. 96 Longchuanwu Rd Qianjiang Economy Dev. Zone, YuhangDist,

Hangzhou, Zhejiang Province, China 311100

Tel: +86 571 86376106 www.ledtestlab.com

Zonal Lumen Tabulation- Goniophotometer Method

γ(°) Lumens % Total

0- 10 20.859 1.49%

10- 20 60.743 4.33%

20- 30 95.254 6.79%

30- 40 121.553 8.66%

40- 50 137.845 9.82%

50- 60 143.34 10.22%

60- 70 138.992 9.91%

70- 80 127.317 9.07%

80- 90 112.365 8.01%

90-100 98.153 7.00%

100-110 84.922 6.05%

110-120 72.169 5.14%

120-130 60.137 4.29%

130-140 48.621 3.47%

140-150 37.264 2.66%

150-160 25.484 1.82%

160-170 13.515 0.96%

170-180 4.609 0.33%

Total 1403.1 100%

γ(°) Lumens % Total

0- 60 579.594 41.31%

60- 90 378.674 26.99%

0-90 958.268 68.29%

90- 180 444.874 31.71%

0- 180 1403.1 100%

Table 5: Zonal Lumen

Page 12: Report No.: HZ19050020b - GREEN CREATIVE€¦ · Model : 8T8/3F/840/DIR/RC Electrical Ratings : 1 20-277V, 60Hz, 8W ... Test was conducted without a dimmer in the circuit. The stabilization

Report No.: HZ19050020b

Prepared by: Leading Testing Laboratories Page 12 of 18

3rd Floor, Bld. 2, NO. 96 Longchuanwu Rd Qianjiang Economy Dev. Zone, YuhangDist,

Hangzhou, Zhejiang Province, China 311100

Tel: +86 571 86376106 www.ledtestlab.com

Illuminance Plots- Goniophotometer Method

Chart 5: Illuminance Plot (Footcandles)

Page 13: Report No.: HZ19050020b - GREEN CREATIVE€¦ · Model : 8T8/3F/840/DIR/RC Electrical Ratings : 1 20-277V, 60Hz, 8W ... Test was conducted without a dimmer in the circuit. The stabilization

Report No.: HZ19050020b

Prepared by: Leading Testing Laboratories Page 13 of 18

3rd Floor, Bld. 2, NO. 96 Longchuanwu Rd Qianjiang Economy Dev. Zone, YuhangDist,

Hangzhou, Zhejiang Province, China 311100

Tel: +86 571 86376106 www.ledtestlab.com

Luminous Intensity Distribution Plots- Goniophotometer Method

Chart 6: Isocandela Plot

Chart 7: Polar Candela Distribution

Page 14: Report No.: HZ19050020b - GREEN CREATIVE€¦ · Model : 8T8/3F/840/DIR/RC Electrical Ratings : 1 20-277V, 60Hz, 8W ... Test was conducted without a dimmer in the circuit. The stabilization

Report No.: HZ19050020b

Prepared by: Leading Testing Laboratories Page 14 of 18

3rd Floor, Bld. 2, NO. 96 Longchuanwu Rd Qianjiang Economy Dev. Zone, YuhangDist,

Hangzhou, Zhejiang Province, China 311100

Tel: +86 571 86376106 www.ledtestlab.com

Luminous Intensity Data- Goniophotometer Method

Table 6: Luminous Intensity Data

Page 15: Report No.: HZ19050020b - GREEN CREATIVE€¦ · Model : 8T8/3F/840/DIR/RC Electrical Ratings : 1 20-277V, 60Hz, 8W ... Test was conducted without a dimmer in the circuit. The stabilization

Report No.: HZ19050020b

Prepared by: Leading Testing Laboratories Page 15 of 18

3rd Floor, Bld. 2, NO. 96 Longchuanwu Rd Qianjiang Economy Dev. Zone, YuhangDist,

Hangzhou, Zhejiang Province, China 311100

Tel: +86 571 86376106 www.ledtestlab.com

Table 7: Luminous Intensity Data

Page 16: Report No.: HZ19050020b - GREEN CREATIVE€¦ · Model : 8T8/3F/840/DIR/RC Electrical Ratings : 1 20-277V, 60Hz, 8W ... Test was conducted without a dimmer in the circuit. The stabilization

Report No.: HZ19050020b

Prepared by: Leading Testing Laboratories Page 16 of 18

3rd Floor, Bld. 2, NO. 96 Longchuanwu Rd Qianjiang Economy Dev. Zone, YuhangDist,

Hangzhou, Zhejiang Province, China 311100

Tel: +86 571 86376106 www.ledtestlab.com

EQUIPMENT LIST

Test Equipment Model Equipment

No.

Calibration

Date

Calibration

Due date

Goniophotometer system GO-R5000 HZTE011-01 Aug. 14, 2018 Aug. 13, 2019

Digital Power Meter PF2010A HZTE028-01 Sep. 12, 2018 Sep. 11, 2019

AC Power Supply DPS1060 HZTE001-06 Aug. 09, 2018 Aug. 08, 2019

DC Power Supply WY12010 HZTE004-03 Aug. 09, 2018 Aug. 08, 2019

Temperature recorder JM624U HZTE018-08 Aug. 09, 2018 Aug. 08, 2019

Temperature and humidity recorder JR900 HZTE018-01 Aug. 09, 2018 Aug. 08, 2019

Standard source D908 HZTE012-01 Aug. 14, 2018 Aug. 13, 2019

Integrate Sphere system 3M HZTE015-04 Aug. 16, 2018 Aug. 15, 2019

Digital Power Meter WT210 HZTE008-01 Aug. 02, 2018 Aug. 01, 2019

AC Power Supply PCR 500L HZTE001-07 Aug. 09, 2018 Aug. 08, 2019

DC Power Supply IT6154 HZTE004-04 Aug. 09, 2018 Aug. 08, 2019

Standard source SCL-1400 HZTE012-02 Aug. 16, 2018 Aug. 15, 2019

Temperature and humidity recorder JR900 HZTE018-02 Aug. 09, 2018 Aug. 08, 2019

Temperature Meter TES1310 HZTE017-01 Aug. 09, 2018 Aug. 08, 2019

Table 8: Test Equipment List

TEST METHODS

Seasoning of SSL Product

For the purpose of rating new SSL products, SSL products shall be tested with no seasoning.

Therefore, no seasoning was performed.

Sphere-Spectroradiometer Method- Photometric and Electrical Measurements

A Labsphere Model CDS 2100 Spectroradiometer and Two Meter Sphere was used to measure correlated color

temperature, chromaticity coordinates, and the color rendering index for each SSL unit. The coating reflectance

of each sphere is 98%. The measure geometry is 4π. Self-absorption correction is conducted in testing.

Bandwidth of spectroradiometer is 350nm-1050nm.

Ambient temperature was measured at a position inside the sphere. Each SSL unit was operated on the client

provided driver at the rated input voltage in its designated orientation.

The stabilization time typically ranges from 30 min (small integrated LED lamps) to 2 or more hours for large

SSL luminaires). It can be judged that stability is reached when the variation (maximum – minimum) of at least

3 readings of the light output and electrical power over a period of 30 min, taken 15 minutes apart, is less than

0.5 %.

Electrical measurements including voltage, current, and power were measured using the Yokogawa Power

Analyzer.

The standard reference of the integrated sphere system is halogen incandescent lamp, the intensity distribution

type is omni-directional, and is traceable to the National Institute of Standards and Technology.

Page 17: Report No.: HZ19050020b - GREEN CREATIVE€¦ · Model : 8T8/3F/840/DIR/RC Electrical Ratings : 1 20-277V, 60Hz, 8W ... Test was conducted without a dimmer in the circuit. The stabilization

Report No.: HZ19050020b

Prepared by: Leading Testing Laboratories Page 17 of 18

3rd Floor, Bld. 2, NO. 96 Longchuanwu Rd Qianjiang Economy Dev. Zone, YuhangDist,

Hangzhou, Zhejiang Province, China 311100

Tel: +86 571 86376106 www.ledtestlab.com

The uncertainty of integrating sphere system reported in this document is expended uncertainty is 2.1% with a

coverage factor k=2.

Goniophotometer Method

Photometric and Electrical Measurements

An EVERFINE Type C Model GO-R5000 Goniophotometer was used to measure the intensity at each angle of

distribution for each sample. The photometric distance is 2.475m for near-field measurement or 30m for

far-field measurement. Bandwidth of spectroradiometer is 380nm-780nm.

Ambient temperature was measured at the same height of the sample mounted on the Goniophotometer

equipment. Each SSL unit was operated on the client provided driver at the rated input voltage in its designated

orientation.

The stabilization time typically ranges from 30 min (small integrated LED lamps) to 2 or more hours for large

SSL luminaires). It can be judged that stability is reached when the variation (maximum – minimum) of at least

3 readings of the light output and electrical power over a period of 30 min, taken 15 minutes apart, is less than

0.5 %.

Electrical measurements including voltage, current, and power were measured using the Everfine Digital Power

Meter.

Some graphics were created with Photometric Plus software.

The standard reference of the Goniophotometer system is halogen incandescent lamp, the intensity distribution

type is omni-directional, and is traceable to the National Institute of Metrology P.R. China.

The uncertainty of goniophotometer system reported in this document is expended uncertainty is 2.3% with a

coverage factor k=2.

Color Characteristics Measurements

The color characteristics of SSL products include chromaticity coordinates, correlated color temperature, and

color rendering index. These characteristics of SSL products may be spatially non-uniform, and thus, in order

that they can be specified accurately, the color quantities shall be measured as values that are spatially average,

weighted to intensity, over the angular range where light is intentionally emitted from the SSL product. The

color characteristics measurements are using gonio-spectroradiometer.

Color Spatial Uniformity

The characteristics of SSL products may be spatially non-uniform, the chromaticity coordinate shall be

measured at two vertical planes (C=0°/180° and C=90°/270°) and at 10° or less intervals for vertical angle until

the light output dropped to below 10% of the peak intensity. The averaged weighted chromaticity coordinate

Page 18: Report No.: HZ19050020b - GREEN CREATIVE€¦ · Model : 8T8/3F/840/DIR/RC Electrical Ratings : 1 20-277V, 60Hz, 8W ... Test was conducted without a dimmer in the circuit. The stabilization

Report No.: HZ19050020b

Prepared by: Leading Testing Laboratories Page 18 of 18

3rd Floor, Bld. 2, NO. 96 Longchuanwu Rd Qianjiang Economy Dev. Zone, YuhangDist,

Hangzhou, Zhejiang Province, China 311100

Tel: +86 571 86376106 www.ledtestlab.com

was calculated from these points. The data was then analyzed to check for delta color differences of the u', v'

chromaticity coordinates. The spatial non-uniformity of chromaticity, ∆u'v', is determined as the maximum

deviation (distance on the CIE (u', v') diagram) among all measured points from the spatially averaged

chromaticity coordinate.

The geometry for the chromaticity measurement using gonio-spectroradiometer is shown as following.

*** End of Report ***

This report is considered invalidated without the Special Seal for Inspection of the LTL. This report shall not be altered, increased

or deleted. The results shown in this test report refer only to the sample(s) tested. Without written approval of LTL, this test report

shall not be copied except in full and published as advertisement.