report - regent products corp. · (86)755-86000151 (ext 6207 16225) [email protected]...

36
BUREAU VERITAS Bureau Veritas Shenzhen Co., ltd 4/F, Block B, Minlida lnduslrial Building, 41h Zone Of Honghualing lnduslr ial Park, X iii Town, Nanshan Dislricl, Shenzhen, Guangdong, P.R.C. Tel:86·755·86000"151 fax: 8755·86000159 www.bureauveritas.com/cps REPORT Technical Report: (8513)329-0088 Page 1 of 36 DEC11,2013 is gove rned by, aod incorporal es hy reference, t ho Conrhtions or Testing as posted at the date or issuance of this rti!porl nt hflp:l/www.cps.bureauverilas com and is intended for your exclusive use. Any copying or replicabon of this report to or for any other pP.rson or enh!y, or usA or our name or lti=ldt=!nl.ark, is permillecJ only \'1tl h Ot tr prior v:ritleo pennission. This re port sets forth our findtngs solely respect to the lest identified herein. The results set forth in this report me not indtcv tive or represental.i'.'C of the quality or characteristi cs of the Jo t from which test sample was II'! ken o r any simll<tr or identkal product unless specifically antJ expressly noled. Our report mc!udes all of the l &sls requested by you and the resul ts l!tereor based upnn the infornlt'llion you provldctl to us. You have 60 days from da ta of issuance of lhts report to nuhfy us of any mall!:tiol ot or omission by our negligence; provided, howavt:!r,lhal such not n::e shall be In \vril ing l'lnd sha!l specificAlly address the issue you wish to mise. A fa ilure to raise such i:;sue willlln the prescribed time shall constitute you unqualified acceptance of th e comp!etenec:s or this rerofl, the testg conducted and the correc.tnes-; of the re1Jor1 con tents.

Upload: others

Post on 08-Nov-2020

3 views

Category:

Documents


0 download

TRANSCRIPT

Page 1: REPORT - Regent Products Corp. · (86)755-86000151 (Ext 6207 16225) John.hong@cn.bureauveritas.com Randy.huang@cn.bureauveritas.com Administrative questions, please contact: Ann An

BUREAU VERITAS

Bureau Veritas Shenzhen Co., ltd 4/F, Block B, Minlida lnduslrial Building, 41h Zone Of Honghualing lnduslrial Park, X iii Town, Nan shan Dislricl, Shenzhen, Guangdong, P.R. C. Tel:86·755·86000"151 fax: 86·755·86000159 www.bureauveritas.com/cps

REPORT Technical Report: (8513)329-0088

Page 1 of 36 DEC11,2013

~port is governed by, aod incorpora les hy re ference, tho Conrhtions or Testing as posted at the date or issuance of this rti!porl nt hflp:l/www.cps.bureauverilas com and is intended for your exclusive use. Any copying or replicabon of this report to or for any other pP.rson or enh!y, or usA or our name or lti=ldt=!nl.ark, is permillecJ only \'1tlh Ot tr prior v:ritleo pennission. This report sets forth our findtngs solely ~·.ith respect to the lest sampl~s identified herein. The results set forth in this report me not indtcv tive or represental.i'.'C of the quality or characteristics of the Jo t from which ~ test sample was II'! ken or any simll<tr or identkal p roduct unless specifically antJ expressly noled. Our report mc!udes all of the l&sls requested by you and the results l! tereor based upnn the infornlt'llion th;~t you provldctl to us. You have 60 days from data of issuance of lhts report to nuhfy us of any mall!:tiol c«ot or omission cau~ed by our negligence; provided, howavt:!r,lhal such notn::e shall be In \vril ing l'lnd sha!l specificAlly address the issue you wish to mise. A fa ilure to raise such i:;sue willlln the prescribed time shall constitute you unqualified acceptance of the comp!etenec:s or this rerofl, the testg conducted and the correc.tnes-; of the re1Jor1 con tents.

Page 2: REPORT - Regent Products Corp. · (86)755-86000151 (Ext 6207 16225) John.hong@cn.bureauveritas.com Randy.huang@cn.bureauveritas.com Administrative questions, please contact: Ann An

BUREAU VERITAS

MONDAY BEAUTY LTD 2810, 28/F PAULY CENTRE, 51 HUNG TO ROAD, KWUN TONG, HONG KONG ATTN: SUNNY YU I EAGLE I NELSON I

CANDY/STEPHEN/GARY C. C.: EMAIL: [email protected] I

[email protected] I [email protected] I [email protected] I [email protected] I [email protected]

SUBMISSION PROCESS

Sample Collection:

D Initial Sample Collection (OC's 115/6 Only)

D Second Sample Collection (DC's 2{3/4/6!7/BI9/10/411/412)

D Single Sample Collection . (All DC's- 50% of Entire Quantity Produced)

0 Random Sampling of Failure {All DC's- 90% of Entire Quantity Produced)

D Random Sampling of Failure w/ Prop 65 (DC 4/9 & Non-DC 4/9-90% of Entire Quantity Produced)

D Vendor Direct

TEST REPORT

LAB LOCATION: LAB NUMBER: CLIENT NO.: DEPARTMENT:

DATE IN: DATE OUT: MOD. LOGIN: REVISED DATE:

PAGE:

PASS

SHENZHEN (8513)329-0088 I I

NOV 26,2013 DEC 11,2013 NOV 29, 2013 I

2 of 36 OVERALL RATING

SATISFACTORY

CORRECTIVE ACTION REQUIRED

FAIL

FAIL-ACCEPT

US CN

X X

RANDOM SAMPLING REQUIRED "VENDOR PLEASE NOTE RANDOM SAMPLING

IS REQUIRED ON ALL FAILED REPORTS**

HD

TESTING FOR TOXICS IN PACKAGING CLEARINGHOUSE (V2)

XXX - 09062.3 - NA METAL METAL ALLOY FOOD CONTACT ARTICLE (V14)

CPSD - 06001.05 - US FOOD CONTACT ARTICLE (V5)

CPSD • 06001 - US FOOD CONTACT ARTICLE (V11)

XXX - 06001 - NA NON-REGULATORY ANALYTICAL TESTING (V7)

XXX- 08443 - NA FOODWARE- KITCHEN TOOLS, UTENSILS & GADGETS (V17)

XXX - 06052 • NA CALIFORNIA PROPOSITION 65 (V49)

XXX-06572-US

Page 3: REPORT - Regent Products Corp. · (86)755-86000151 (Ext 6207 16225) John.hong@cn.bureauveritas.com Randy.huang@cn.bureauveritas.com Administrative questions, please contact: Ann An

!IUHEAU VERITAS

Sample Description: SPLATTER SCREEN 2 ASTD Dollar Tree Direct (DTD) Sample Description: 1/ Final Packaging: Yes (submitted for review) I X I No (not submitted for review) I I Submitter: MONDAY BEAUTY

LTD Country of Ori!'lin: CHINA Country of Sale: USA/CANADA DTD Country of Sale: Color:

Department Number: I Sub-Department No. I

Previous Report No.: I Revised Report: Yes: I I No: I X Charge Vendor: Yes: I X I No: I Test Type: Reason For Revision: I

Vendor Number: I

Style: E3 Order:

DTSC SKU Number(s): P.O. Number(s) (USA):

Additional PO No (USA):

119125 3246348/ 3246350/ 3246352(USA)

P.O. Number(s) (Canada): 3246324/3246326/ 3246328(CAN)

Additional PO No (Canada): I DTD SKU: I

DTD PO No.: I Vendor Item Number: I

(8513)329-0088 Page 3 of 36

TEST PROPERTY PASS SATISFACTORY CAR FAIL DATA COMMENTS

Labeling X Physical Characteristics X Construction Qualities X Performance X Colorfastness I Flammability X Analytical X

HD

Page 4: REPORT - Regent Products Corp. · (86)755-86000151 (Ext 6207 16225) John.hong@cn.bureauveritas.com Randy.huang@cn.bureauveritas.com Administrative questions, please contact: Ann An

BUREAU AlJI:INIIl·M

REMARK(S):

1. See enclosed protocol(s) for the test results.

2. In this report, full test was performed on all styles.

3. The following test result was upon document review of previous report(5213)275-0564 • Heavy metals content in packaging materials

4. As per request, the following test was not tested in this report • GRAS evaluation

If there are questions regarding above report, please contact the appropriate lab personnel.

Technical questions, please contact: John Hong I Randy Huang (86)755-86000151 (Ext 6207 16225) [email protected] [email protected]

Administrative questions, please contact: Ann An I Shirley Liu (+86)755-86000151 (Ext 6210 16446) [email protected] [email protected]

BUREAU VERITAS SHENZHEN CO., LTD

BRIAN TAM MANAGER- HARDLINES DIVISION

HD

(8513)329-0088 Page 4 of 36

Page 5: REPORT - Regent Products Corp. · (86)755-86000151 (Ext 6207 16225) John.hong@cn.bureauveritas.com Randy.huang@cn.bureauveritas.com Administrative questions, please contact: Ann An

*

*

BUREAU VERITAS

Heavy metals content in packaging materials- documentation review

Heavy metals content in packaging materials

HD

Model taxies in packaging legislation of the taxies in packaging clearinghouse (TPCH)

Model taxies in packaging legislation of the Taxies in Packaging Clearinghouse (TPCH) I

CPSD-AN-00065-MTHD

BV Lab Number: (8513)329-0088

Technician Name: BRAN

Test Date: DEC 09-11,2013

Reviewed By/Date: ALICE I DEC I 1,2013

Page 5 of36

XXXX TEST PROTOCOL FOR

Varies

XXX- 09062.3- NA

stun of concentration of lead, cadmium, mercury and hexavalent chromium in packaging or packaging components shall not exceed 100 mg!kg (100 ppm) by weight.

Note: 1. Total chromium (Cr) is determined ftrst. Confirmation of hexavalent chromium (Cr VI) will be performed when concentration of total chromium is above the detection limit and sum of concentration of four heavy metals is exceeded the limit. 2. Max. composite up to 3 like materials. 3. Composite across styles is acceptable.

Client

M DOCUMENT PROVIDED

SEE REMARK

NA

PASS

Page 6: REPORT - Regent Products Corp. · (86)755-86000151 (Ext 6207 16225) John.hong@cn.bureauveritas.com Randy.huang@cn.bureauveritas.com Administrative questions, please contact: Ann An

B'UREAU VER ITAS

Key:

* ** #

Result Key: c R M NM NA NT

Rating Kev: PASS FAIL MARG

CAR

HD

Additional Charge For This Test Mandatory Requirement By Request Only

Claimed Recorded Meets Does Not Meet Not Applicable Not Tested

Pass Fail Marginal Corrective Action Required

BV Lab Number:

Technician Name:

Test Date:

Reviewed By/Date:

Client Approval:

Creation Date: Last Revision Date: Pricing Review Date: Technical Review Date:

(8513)329-0088

BRAN

DEC 09-11,2013

ALICE/DEC 11.2013

Page 6 of36

OCTOBER 16,2012/ Debbie Smith OCTOBER 20, 2008 OCTOBER 12,2012 JANUARY 20,2001

Page 7: REPORT - Regent Products Corp. · (86)755-86000151 (Ext 6207 16225) John.hong@cn.bureauveritas.com Randy.huang@cn.bureauveritas.com Administrative questions, please contact: Ann An

BUREAU VERITAS

# California Proposition 65

HD

CPSD-AN-PTCL-06572-US

BV Lab Number:

Technician Name:

Test Date:

Reviewed By/Date:

BUREAU VERITAS TEST PROTOCOL FOR

CPSD- 0600L05- US

The sample should be California Proposition 65 to detennine · testing or labeling is required.

For samples that fall under the scope ofCAProp 65 requirements with testing limit(s) but does not contain appropriate labeling (refer to labeling section for detail), actual testing will be conducted. Othenvise, actual testing is not required and report as "Pass" if the ·

(8513)329-0088

BRAN

DEC 09-11,2013

ALICE I DEC 11,2013

Page 7 of36

SEE XXX-06572-US

Page 8: REPORT - Regent Products Corp. · (86)755-86000151 (Ext 6207 16225) John.hong@cn.bureauveritas.com Randy.huang@cn.bureauveritas.com Administrative questions, please contact: Ann An

*

*

*

BUREAU VERITAS

Extractable lead and cadmium in silver plated hollowware

Lead content in pewter alloys

Lead content in solder and flux

HD

FDA CPG 7117.05 and 7117.06 I AOAC

973.32 (2007) I CPSD­AN-00012-MTHD

BV Lab Number:

Technician Name:

Test Date:

Reviewed By/Date:

CPSD- 06001.05- US

Cadmium (Cd): 0.25 ppm (mg!L) (Any one of 6 units for Large hollowware) 0.5 ppm (mg/L) (Any one of 6 units for Small hollowware/Cups/Mugs) 0.5 ppm (mg!L) (Average of6 units for Flatware)

Lead (Pb): 7.0 ppm (mg/L) (Average of6 units for article intended for use by adult) 0.5 ppm (mg!L) (Any one of 6 units for article intended for use by infants and children)

Note: -Test only food contact surfaces intended to hold liquid. No test is required for spoon and fork. - Cadmium ( Cd) limit in pitchers refer to the limit of small or large hollowware. -Cadmium (Cd) limits are with reference to CPG 7117.06.

(8513)329-0088

BRAN

DEC 09-11,2013

ALICE I DEC 11,2013

Page 8 of36

NA

NA

NA

Page 9: REPORT - Regent Products Corp. · (86)755-86000151 (Ext 6207 16225) John.hong@cn.bureauveritas.com Randy.huang@cn.bureauveritas.com Administrative questions, please contact: Ann An

BUREAU V E R ITAS

* GRAS evaluation

* Extractable lead and cadmium in tableware

Note 1: According to FDA 2009 Food Code,

BV Lab Number:

Technician Name:

Test Date:

Reviewed By/Date:

CPSD- 06001.05- US METAL METAL ALLOY FOOD CONTACT ARTICLE

California health and safety code section

108860 I AOAC 973.32 (2007) I ASTM C738-94 (R20 11) I CPSD­AN-00011-MTHD

Cadmium (Cd): 0.25 ppm (mg!L) (Any one of6 units for Large hollowware) 0.5 ppm (mg!L) (Any one of 6 units for Small hollowware/Cups/Mugs) 0.5 ppm (mg!L) (Average of6 units for Flatware)

Lead (Pb): 1.0 ppm (mg!L) (Any one of 6 units for Large hollo\VWare) 2.0 ppm (mg!L) (Any one of6 units for Small hollo\VWare) 0.5 ppm (mg!L) (Any one of6 units for Cups!Mugs!Pitchers) 3.0 ppm (mg/L) (Average of 6 units for Flatware)

Note: -Test only food contact surfaces intended to hold liquid. -Cadmium (Cd) limit in pitchers refer to the limit of small or

(8513)329-0088

BRAN

DEC 09-11,2013

ALICE/DEC 11,2013

Page 9 of36

NT SEE REMARK

NA

a. 4-101.12, Cast Iron may not be used for utensils or food contact surfaces of equipment except it may be used as a surface for cooking or used in utensils for serving food if the utensils are used only as part of an uninterrupted process from cooking through service. b. 4-l 0 1.14, Copper and copper alloys such as brass may not be used in contact with food that has a pH below 6 such as vinegar, fruit juice, or wine or for a fitting or tubing installed between a backflow prevention device and a carbonator. It may be used in contact with beer brewing ingredients that have a pH below 6 in the prefermentation and fermentation steps of a beer brewing operation such as a brewpub or micro brewery. c. 4-101.15, Galvanized metal may not be used for utensils or food contact surfaces of equipment that are used in contact Vlith acidic food. d. 4-101.18, Nonstick coating, kitchenware such as frying pans, griddles, sauce pans, cookie sheets and waffle bakers that have a perfluorocarbon resin coating shall be used with nonscoring or nonscratching utensils and cleaning aids.

HD

Page 10: REPORT - Regent Products Corp. · (86)755-86000151 (Ext 6207 16225) John.hong@cn.bureauveritas.com Randy.huang@cn.bureauveritas.com Administrative questions, please contact: Ann An

I>UREAU VERITAS

Kev: -*-" #

Result Key: c R M NM NA NT

Rating Key; PASS FAIL

HD

Additional Charge For This Test Mandatory Requirement By Request Only

Claimed Recorded Meets Does Not Meet Not Applicable Not Tested

Pass Fail

Additional 2 pes for GRAS evaluation. Additional 6 pes for extractable lead and cadmium in silver plated hollowware/tableware. Additional sample may be requested if insufficient.

BV Lab Number:

Technician Name:

Test Date:

Reviewed By/Date:

Client Approval: Creation Date: Last Revision Date: Pricing Review Date:

Technical Review Date:

(8513)329-0088

BRAN

DEC 09-11,2013

ALICE I DEC 11,2013

Page 10 of36

FEBRUARY 12,2010 JULy 04, 2013 AUGUST 03,2010

Page 11: REPORT - Regent Products Corp. · (86)755-86000151 (Ext 6207 16225) John.hong@cn.bureauveritas.com Randy.huang@cn.bureauveritas.com Administrative questions, please contact: Ann An

BV Lab Number:

Technician Name:

Test Date:

8UREAU Reviewed By/Date:

VERITAS

BUREAU VERITAS TEST PROTOCOL FOR

*

*

*

*

*

tests for articles intended to contact with food and

Plastic

Paper and paperboard

Ceramic, porcelain, glass and enamel

Wood

Metal and metal alloy

GRAS in natural material (non-wood)­document review

21 CFR 170-189 FDA Generally Recognized

as Safe (GRAS) Guidelines I FDA

Opinion I CPSD-AN-G00007-STIP02/ CPSD-GB-0000 1-

STIP03

Note 1: CPSD-AN-PTCL-06001.04-US will be offered to program client only.

HD

CPSD- 06001 -US

in CPSD-AN-PTCL-

except (non-wood) intended to come into contact with food shall meet FDA GRAS requirement. All additives in that material, such as glue shall also meet FDA GRAS requirement. Client shall provide the documentation with material bill or composition for material identification. It is acceptable for the client to submit either a FDA letter or, if there is infonnation from FDA

is acceptable. a guarantee letter material is the only food grade material used in

can also be

(8513)329-0088

BRAN

DEC 09-11,2013

ALICE I DEC 11,2013

Page 11 of36

NA

NA

NA

NA

PASS

NA

Page 12: REPORT - Regent Products Corp. · (86)755-86000151 (Ext 6207 16225) John.hong@cn.bureauveritas.com Randy.huang@cn.bureauveritas.com Administrative questions, please contact: Ann An

BUREAU VERITAS

~ * ** #

Result Key: c R M NM NA NT

Rating Key: PASS FAlL

HD

Additional Charge For This Test Mandatory Requirement By Request Only

Claimed Recorded Meets Does Not Meet Not Applicable Not Tested

Pass Fail

BV Lab Number:

Technician Name:

Test Date:

Reviewed By/Date:

Client Approval: Creation Date: Last Revision Date: Pricing Review Date: Technical Review Date:

(8513)329-0088

BRAN

DEC 09-11,2013

ALICE I DEC 11,2013

Page 12 of36

I JANUARY 29, 2009 JANUARY 09,2013

Page 13: REPORT - Regent Products Corp. · (86)755-86000151 (Ext 6207 16225) John.hong@cn.bureauveritas.com Randy.huang@cn.bureauveritas.com Administrative questions, please contact: Ann An

BUREAU VERITAS

* Leachable lead in kettles

* Extractable lead and cadmium - interior

HD

CPSD-AN-PTCL-06001-US

Hazardous Products (Kettles) Regulations J

CPSD-AN-00493-

Glazed Ceramics and Glassware Regulations (SOR/98-176) I CPSD-

AN-00011-MTHD

6

BV Lab Number:

Teclmician Name:

Test Date:

Reviewed By/Date:

XXXX TEST PROTOCOL FOR

Food contact article, which is completely or partly made of ceramic, porcelain or glass and completely or partly covered with coating, glaze or decoration, shall not contain extractable lead (Pb) and cadmium (Cd) exceed the following limits:

Cadmium (Cd): 0.25 ppm (mg!L) (any one of 6 units for Large hollo\V\Vare and Pitchers) 0.5 ppm (mg/L) (any one of 6 units for Small hollowware, Cups and Mugs) 0.5 ppm (mg!L) (any one of6 units for Flatware)

Lead (Pb): 1.0 ppm (mg!L) (any one of6 units for Large hollowware) 2.0 ppm (mg!L) (any one of 6 units for Small hollowware) 0.5 ppm (mg!L) (any one of 6 units for Cups, Mugs and Pitchers)

(8513)329-0088

BRAN DEC 09-11,2013

ALICE/DEC 11,2013

Page 13 of36

M SEE CPSD-0600 I-US

PASS

NA

NA

Page 14: REPORT - Regent Products Corp. · (86)755-86000151 (Ext 6207 16225) John.hong@cn.bureauveritas.com Randy.huang@cn.bureauveritas.com Administrative questions, please contact: Ann An

BUREAU VERITAS

* ~xtractable lead and cadmium in lip and nm

HD

Glazed Ceramics and Glassware Regulations (SOR!98-J 76) I CPSD-

AN-00011-MTHD

6

BV Lab Number:

Technician Name:

Test Date:

Reviewed By/Date:

XXX- 06001- NA

External decorated lip and rim area of beverage products shall not contain extractable lead (Pb) and cadmium (Cd) exceed the following limits in any of the 6 units:

Cadmium (Cd): 0.4 ppm (mg!L) Lead (Pb): 4.0 ppm (mg!L)

Note: For drinking vessel with decoration on lip and rim area from the

(8513)329-0088

BRAN

DEC 09-11,2013

ALICE I DEC 11,2013

Page 14 of36

NA

Page 15: REPORT - Regent Products Corp. · (86)755-86000151 (Ext 6207 16225) John.hong@cn.bureauveritas.com Randy.huang@cn.bureauveritas.com Administrative questions, please contact: Ann An

BUREAU VERITAS

* Bisphenol A content

HD

Various US state laws (e.g. CT Public Act#

09-103 andMN Chapter 40 SF #247) I Canada

Consumer Product Safety Act

(S.C.2010,c.21), Schedule 2, item 15 I

CPSD-k'I-00169-MTHD

BV Lab Number:

Technician Name:

Test Date:

Reviewed By/Date:

XXX - 06001 - NA

~:~;~;:::g:::~~~~s1 norconram any det<octab1e o: (BPA) (BV reporting limit is lmg/kg): a. Infant formula/ baby food plastic container,jar or can b. All reusable food or beverage containers including their lids (if any), c. Baby products other than (a) and (b), d. Straws

"Infant formula" means a commercially available milk based or soy based powder, concentrated liquid or ready-to-feed substitute for human breast milk that is intended for infant consumption. "Baby food" means a commercially available prepared solid food consisting of a soft paste or an easily chewed food that is intended for consumption by children two years of age or younger. "Baby product" means products, including but not limited to pacifiers, bibs, toys, changing pad ... etc, intended to use by children three years of age or younger. "Reusable food or beverage container" means a receptacle for storing food or beverages, including, but not limited to, baby bottles, spill~proof cup, sports bottles and thermoses, and excluding containers intended for disposal after initial use.

Report actual results or include data table within report. Note: ~ Actual testing will be conducted on:

(i) all accessible plastic materials in the product, (ii) food contact plastic parts in the product.

-Vendors shall be responsible for the compliance of all other materials. -It is not applicable on polycarbonate resins in infant feeding bottles (baby bottles) and spill~proof cups including their closures and lids, designed to help train babies and toddlers to drink from cups (sippy cups), as it is banned per 21 CFR

. 580.

(8513)329-0088

BRAN DEC 09-11,2013

ALICE I DEC 11,2013

Page 15 of36

NA

Page 16: REPORT - Regent Products Corp. · (86)755-86000151 (Ext 6207 16225) John.hong@cn.bureauveritas.com Randy.huang@cn.bureauveritas.com Administrative questions, please contact: Ann An

BUREAU VERITAS

' Total lead content in surface coatings

HD

Canada Consumer Products Containing Lead (Contact with Mouth) Regulations (SOR/2010-273) I CPSD-AN-00461-

MTHD

BV Lab Number:

Technician Name:

Test Date:

Reviewed By/Date:

XXX- 06001 - NA

Products for all ages (including adults) that have accessible surface coatings that come into contact with the user's mo~tth during normal use shall not contain lead or lead components in which the lead content is in excess of0.009% (90ppm) of the weight of the total content.

Report actual results or include data table within report.

Component testing is allowed. Compositing is not allowed.

Note: The following products are excluded: - Kitchen utensils -Jewelry under Children's Jewelry Regulations -Products subject to Glazed Ceramic and Glassware

(8513)329-0088

BRAN DEC 09-11,2013

ALICE I DEC 11,2013

Page 16 of36

NA

Page 17: REPORT - Regent Products Corp. · (86)755-86000151 (Ext 6207 16225) John.hong@cn.bureauveritas.com Randy.huang@cn.bureauveritas.com Administrative questions, please contact: Ann An

BUREAU VERITAS

* Total lead content in substrate materials

HD

Canada Consumer Products Containing Lead (Contact with Mouth) Regulations (SOR/2010-273) I CPSD-AN-00461-

MTHD

BV Lab Number:

Technician Name:

Test Date:

Reviewed By/Date:

XXX- 06001- NA

Products for all ages (including adults) that have accessible substrates that come into contact with the user's mouth during normal use shall not contain lead or lead components in which the lead content is in excess of0.009% (90ppm) of the weight of the total content.

Report actual results or include data table within report.

Component testing is allowed. Compositing is not allowed.

Note: The following products are exclude: - Kitchen utensils, - Jewelry under Chlldren' s Jewelry Regulations -Products subject to Glazed Ceramic and Glassware Regulations. - The following materials will be exempted from testing. It is the vendors responsibility to ensure compliance to the applicable requirements: Non-suspect materials as defined by the Consumer Products Safety Commission in 16 CFR 1500.91 (d) and (c) (refer to exemption list of lead in substrate in the CPSD-GB-PTCL-08444-US protocol for detail)

(8513)329-0088

BRAN

DEC 09-11,2013

ALICE I DEC 11,2013

Page 17 of36

NA

Page 18: REPORT - Regent Products Corp. · (86)755-86000151 (Ext 6207 16225) John.hong@cn.bureauveritas.com Randy.huang@cn.bureauveritas.com Administrative questions, please contact: Ann An

BUREAU VERITAS

Key:

* ** #

Result Key: c R M NM NA NT

Rating Key: PASS FAIL MARG

CAR

HD

Additional Charge For This Test Mandatory Requirement By Request Only

Claimed Recorded Meets Does Not Meet Not Applicable Not Tested

Pass Fail Marginal Corrective Action Required

BV Lab Number:

Technician Name:

Test Date:

Reviewed By/Date:

Client Approval:

CPSD-AN-Creation Date: Last Revision Date: Pricing Review Date: Technical Review Date:

(8513)329-0088

BRAN

DEC 09-11,2013

ALICE/DEC 11,2013

Page 18 of36

AUGUST 05,2013/ Debbie Smith JANUARY 04,2011 OCTOBER 03,2013

Page 19: REPORT - Regent Products Corp. · (86)755-86000151 (Ext 6207 16225) John.hong@cn.bureauveritas.com Randy.huang@cn.bureauveritas.com Administrative questions, please contact: Ann An

BUREAU VERITAS

' Total lead content in surface coatings

' Total lead content in surface coatings

AOAC 974.02 modified I CPSD-AN-00001-

MTHD

CPSD-AN-00009-MTHD

BV Lab Number: (8513)329-0088

Technician Name: BRAN Test Date: DEC 09-11,2013

Reviewed By/Date: ALICE /DEC 11,2013

XXXX TEST PROTOCOL FOR

XXX - 08443 - NA

on items outside of the scope CPR 1303 shall not contain lead or lead components in which the lead content is in excess of 0.060% (600ppm) of the \Veight of the total content.

Report actual results or include data table within report.

Component testing is allowed. Compositing up to 4 like materials is allowed. The composite result will be evaluated against the adjusted limit (regulatory limit divided by the number of composites).

item outside of the scope not contain lead or lead components in which the lead content is in excess of 0.06% (600ppm) of the weight of the total content.

Report actual results or include data table within report.

Component testing is allowed. Compositing up to 4 like materials is allowed.

Client

Page 19 of36

NA NO SURFACE COATING

NA NO SURFACE COATING

IMPORT ANT NOTE: The infonnation presented under the "Criteria" of this protocol is for information only and does not replace the content of the standard. Details of the requirements should be referred to the original standards.

HD

Page 20: REPORT - Regent Products Corp. · (86)755-86000151 (Ext 6207 16225) John.hong@cn.bureauveritas.com Randy.huang@cn.bureauveritas.com Administrative questions, please contact: Ann An

BUREAU VERITAS

Key:

' '* #

Result Kcv: c R M NM NA NT

Rating Key: PASS FAIL MARG

CAR

HD

Additional Charge For This Test Mandatory Requirement By Request Only

Claimed Recorded Meets Does Not Meet Not Applicable Not Tested

Pass Fail Marginal Corrective Action Required

BV Lab Number:

Technician Name:

Test Date:

Reviewed By/Date:

Client Approval:

Creation Date: Last Revision Date: Pricing Review Date: Technical Review Date:

(8513 )329-0088

BRAN

DEC 09-11,2013

ALICE I DEC 11,2013

Page 20 of36

OCTOBER 16,2012/ Debbie Smith FEBRUARY II, 2011 OCTOBER 12,2012

Page 21: REPORT - Regent Products Corp. · (86)755-86000151 (Ext 6207 16225) John.hong@cn.bureauveritas.com Randy.huang@cn.bureauveritas.com Administrative questions, please contact: Ann An

BUREAU V E R ITAS

* California Proposition 65

HD

BV Lab Number: (8513 )329-0088

Technician Name: BRAN Test Date: DEC 09-11,2013

Reviewed Byillate: ALICE I DEC 11,2013

Page 21 of36

XXXX TEST PROTOCOL FOR

cream

pee required if testing to 1 or more supplemental protocol is necessary. Please refer to the above referenced supplemental protocol(s) for additional

XXX-HL-PTCL-06572-US

SEE XXX-06572-US

Page 22: REPORT - Regent Products Corp. · (86)755-86000151 (Ext 6207 16225) John.hong@cn.bureauveritas.com Randy.huang@cn.bureauveritas.com Administrative questions, please contact: Ann An

BUREAU VERITAS

* Food contact articles

HD

XXX-HL-PTCL-06001-NA

BV Lab Number:

Technician Name:

Test Date:

Reviewed By/Date:

conform to the applicable requirements of the Food, Drug, and Cosmetic Act (FDCA), specifically 21 CPR 170 through 189. Special requirements for Plastics: ~In lieu of testing, test report can be submitted if dated within six months. For food contact items containing PVC, PETG, Styrene Block Polymers, Polyester Elastomers or ABS (Acrylonitrile> 30%), it is acceptable for the vendor to submit a test report (dated within six months) indicating that only food grade materials were used in the manufacturing process.

Special requirements for Metal: - All metal components of cups, mugs or other food contact articles shall be constructed of an FDA recognized grade of stainless steel. Stainless Steel Grades: 302, 304, 304F, 316,321,410,416, 420 (cutlery only), 440, 440A, 440C, 904L, A-36 and CF-1018. -For any other grade of stainless steel or other metal, vendor need to provide the list of compositions or will have the material evaluated which shall be submitted to the FDA for review and approval for use in food contact articles. 01 end or shall be responsible for the accuracy of information provided) In lieu of testing, test report can be submitted if dated within six months. Special requirements for ceramic, porcelain, glass or enamel: - As a Dollar Tree Requirement, for California health and safety code section 108870- All tableware items, regardless of extractable Lead & Cadmium test result, distributed in the State of California must be permanently and indelibly marked with the name, or if the item is too small, a registered trademark, of the manufacturer or

(8513 )329-0088

BRAN

DEC 09-11,2013

ALICE I DEC 11.2013

Page 22 of36

SEE XXX-0600!-NA

Page 23: REPORT - Regent Products Corp. · (86)755-86000151 (Ext 6207 16225) John.hong@cn.bureauveritas.com Randy.huang@cn.bureauveritas.com Administrative questions, please contact: Ann An

BV Lab Number: (8513)329-0088

Technician Name: BRAN Test Date: DEC 09-11,2013

Reviewed By/Date: ALICE I DEC 11,2013 BUREAU

Page 23 of36 VERJTAS

* SEE XXX-09062.3-NA

F.P. and L. Act (16 CFR or distributor's name & address (City,

** 500) OR NIST Uniform

PROVIDED DATA Laws and Regulations

Handbook 130

F.P. and L. Act (16 CFR

** 500) OR NIST Uniform

PROVIDED DATA Laws and Regulations

Handbook 130

F.P. and L. Act (16 CFR

" 500) OR NIST Uniform

PROVIDED DATA Laws and Regulations

Handbook 130

** Country of origin 19 CFR 134 M PASS

MADE IN CHINA

Use Labeling M PASS

HD

Page 24: REPORT - Regent Products Corp. · (86)755-86000151 (Ext 6207 16225) John.hong@cn.bureauveritas.com Randy.huang@cn.bureauveritas.com Administrative questions, please contact: Ann An

**

**

**

BUREAU VERITAS

Labeling - packaging - packaging copy or artwork request form may be substituted

Labeling - packaging - packaging copy or artwork request form may be substituted

Labeling - packaging - packaging copy or artwork request form may be substituted

HD

Consumer packaging and labeling regulations,

C.R.C., c. 417

Consumer packaging and labeling regulations,

C.R.C., c. 417

Consumer packaging and labeling regulations,

C.R.C., c. 417

BV Lab Number:

Technician Name:

Test Date:

Reviewed By/Date:

XXX- 06052- NA

M'mufacturer or distributor's name & address (city & zip). Minimum 1.6 mm type size Placed anywhere on outer surface of package except bottom - English or French Where the area of the principal display surface of a container is 1.55 square inches (10 square centimetres) or less, the information may be in letters of not less than 1/32 inch (0.8

Product net quantity PDP, English and French using valid metric word (or, valid metric symbol is deemed bilingual) Numerical portion of net quantity declaration must be in bold face type, type size based on PDP All other information must be clear and legible.

PnJdttctide,ntificati<>ll English and French, PDP in 1.6 mm minimum type size.

Typeface not stipulated must be legible to the consumer. In certain cases where the container has a principal display surface of 10 cm2 (1.55 inz) or less, the minimum type height may be reduced to 0.8 mm (1132 in.). Refer to section 16 of the regulation.An exemption from declaring product identity may apply under the following conditions: 1) product is sold by count and is packaged in a way that it is visible and identifiable.

The label has an accurate pictorial representation

(8513)329-0088

BRAN

DEC 09-11,2013

ALICE I DEC 11,2013

Page 24 of36

M PASS

M PASS

M PASS

Page 25: REPORT - Regent Products Corp. · (86)755-86000151 (Ext 6207 16225) John.hong@cn.bureauveritas.com Randy.huang@cn.bureauveritas.com Administrative questions, please contact: Ann An

**

**

BUREAU VERITAS

Labeling - packaging - packaging copy or artwork request form may be substituted

Labeling - packaging

HD

Consumer packaging and labeling regulations,

C.R.C., c. 417

Consumer packaging and labeling regulations, C.R.C., c. 417 section 6

BV Lab Number:

Technician Name:

Test Date:

Reviewed By/Date:

-The name and address of a Canadian dealer preceded by the words "imported by" (importC par") or "imported for" ("import6 pour"); or -The statement of geographic origin located immediately adiacentto the name and address of a Canadian dealer; or

mandatory labeling information shall be shown in both French and English languages. The type of mandatory labeling that is required includes, but is not limited to, mandatory warning, product identity, net content and ingredient declarations. The names and address of the manufacturer and country of origin labeling requirements may be presented in either French or English. Other supplemental label information that is considered to be non­mandatory (e.g. directions for use) also does not have to appear in a bilingual manner. However, manufacturers are encouraged to include such information in a bilingual format if plausible.

(8513)329-0088

BRAN

DEC 09-11,2013

ALICE/DEC 11,2013

Page 25 of36

M PASS

M PASS

Page 26: REPORT - Regent Products Corp. · (86)755-86000151 (Ext 6207 16225) John.hong@cn.bureauveritas.com Randy.huang@cn.bureauveritas.com Administrative questions, please contact: Ann An

BUREAU VERITAS

** Country of origin marking

* Total lead content in surface coatings

HD

Canada Customs Tariff, Marking of Imported Goods Regulations,

SOR-94-10 I Marking of Imported Goods

MemorandumDll-3-1

Consumer Products Containing Lead

(Contact with Mouth) Regulations I CPSD­AN-00461-MTHD

BV Lab Number:

Technician Name:

Test Date:

Reviewed By/Date:

XXX- 06052- NA

Imported goods shall indicate country of origin. Must be legible and sufficiently permanent to

remain on the goods until it reaches the purchaser. c) For goods from NAFTA countries, the language may be English, French or Spanish. d) For goods from non-NAFTA countries, language may be English or French and marking should appear on individual articles. e) If the packaging conceals the CoWl try of Origin mark, then the packaging must also be marked. f) There is a provision to mark only the container if the goods are imported from NAFTA countries, providing that certain conditions are met, such that the ultimate

will see the marked container.

Products for all ages (including adults) that have accessible surface coatings that come into contact with the user's mouth during normal use shall not contain lead or lead components in which the lead content is in excess of0.009% (90ppm) of the weight of the total content.

Report actual results or include data table -within report.

Client requirement: Component testing is allowed. Compositing is not allowed.

Note: The following products are excluded: -Kitchen utensils - Jewehy under Children's Jewell)' Regulations -Products subject to Glazed Ceramic and Glassware

(8513 )329-0088

BRAN

DEC 09-11,2013

ALICE I DEC 11.2013

Page 26 of36

M MADE IN CHINA

PASS

NA

Page 27: REPORT - Regent Products Corp. · (86)755-86000151 (Ext 6207 16225) John.hong@cn.bureauveritas.com Randy.huang@cn.bureauveritas.com Administrative questions, please contact: Ann An

BUREAU VERITAS

* Total lead content in substrate materials

* Total lead content in surface coatings

HD

Consumer Products Containing Lead

(Contact with Mouth) Regulations I CPSD­AN-00461-MTHD

AOAC 974.02 modified I CPSD-AN-00001-

MTHD

BV Lab Number:

Technician Name:

Test Date:

Reviewed By/Date:

for all ages (including adults) that have accessible substrates that come into contact with the user's mouth during normal use shall not contain lead or lead components in which the lead content is in excess of0.009% (90ppm) of the weight of the total content.

Report actual results or include data table within report.

Client requirement: Component testing is allowed. Compositing is not allowed.

Note: The following products are exclude: - Kitchen utensils, -Jewelry under Children's Jewelry Regulations -Products subject to Glazed Ceramic and Glassware Regulations. -The following materials will be exempted from testing. It is the vendors responsibility to ensure compliance to the applicable requirements: Non-suspect materials as defined by the Consumer Products Safety Commission in 16 CFR 1500.91 (d) and (e) (refer to exemption list of lead in subs_trate in the CPSD-GB-PTCL-08444-US protocol for

items outside of the scope lead or lead components in which the lead content is in excess of0.003% (30ppm) of the weight of the total content.

(8513 )329-0088

BRAN

DEC 09-11,2013

ALICE I DEC 11,2013

Page 27 of36

NA

NA Report actual results or include data table \Vithin report. NO SURFACE COATING

Component testing is allowed. Compositing is not allowed

Client

Page 28: REPORT - Regent Products Corp. · (86)755-86000151 (Ext 6207 16225) John.hong@cn.bureauveritas.com Randy.huang@cn.bureauveritas.com Administrative questions, please contact: Ann An

BUREAU VERITAS

* Total lead content in substrate materials

* Radiation screening test

Sharp points I edges

Exposed edges ~ metals

HD

EPA 3050B modified I EPA 3051A modified I EPA 3052 modified/

CPSD-AN-00007-MTHD I CPSD-AN-

00008-MTHD I CPSD-AN-00164-MTHD

Gamma emission scans

16 CFR 1500.481 1500.49 modified

SOR/20llwl7 section 8 modified

All

All

BV Lab Number:

Technician Name:

Test Date:

Reviewed By/Date:

outside of the scope of CPSIA shall not contain lead in excess o£0.003% (30ppm) of the weight of the total content.

Report actual results or include data table within report.

Component testing is allowed. Compositing is not allowed

Note: Non-suspect materials as defined by the Consumer Products Safety Commission in 16 CFR 1500.91 (d) and (e) (refer to exemption list of lead in substrate in the CPSD-GB­PTCL-08444-US protocol for detail).

parts not exceed 2 times over background radiation

Note: Applicable to all products except food

no sharp points I edges, other than those required

Shall not reveal hazards associated with exposed metal edges. All edges shall be folded back or sprayed with or dipped in paint or otherwise treated in order to eliminate all sharpness and burrs.

Modification =

(8513)329-0088

BRAN DEC 09-11,2013

ALICE I DEC 11,2013

Page 28 of36

M SEE TABLE 1

M ND

M

M

PASS

PASS

PASS

PASS

Page 29: REPORT - Regent Products Corp. · (86)755-86000151 (Ext 6207 16225) John.hong@cn.bureauveritas.com Randy.huang@cn.bureauveritas.com Administrative questions, please contact: Ann An

l,..uv~~

"' ~ " .. Q ~

' '

1.a:zs

BUREAU VERITAS

Exposed edges -plastics

Wooden surfaces. edges and comers

Exposed edges and comers on glass

Exposed ends on wire frame or structure

Flammability Of Solids

HD

SOR/2011-17 section 10 modified

SOR/20 11-17 section 11 modified

SOR/20 11-17 section 12 modified

SOR/20 11-17 section 9 modified

16 CFR 1500A4

All

All

All

All

BV Lab Number:

Technician Name:

Test Date:

Reviewed By/Date:

Shall not reveal hazards from exposed sharp ends on wire frames or structures, prior to or following reasonably foreseeable use. All wire ends shall be covered, turned in or turned back.

<0.1 in

(8513)329-0088

BRAN

DEC 09-11,2013

ALICE I DEC 11,2013

Page 29 of36

NA

NA

NA

NA

M PASS

Page 30: REPORT - Regent Products Corp. · (86)755-86000151 (Ext 6207 16225) John.hong@cn.bureauveritas.com Randy.huang@cn.bureauveritas.com Administrative questions, please contact: Ann An

l,.u ""~

" ~ " , Q ~

1'.82&

BUREAU VERITAS

Capacity ~ volumetric

Seal of attachment or rivets

Actual use- functionality- not covered by other tests

Dishwasher exposure

Operates as Intended

Operates safely

Knives and spatula - bending strength

HD

CPSD-HL-06000-MTHD I Capacity

CPSD-HL-01058-MTHD I Actual usc

CPSD-HL-01014-MTHD I Dishwasher

CPSD-HL-01058-MTHD I Actual use

CPSD-HL-04014-MTHD I Bending force

BV Lab Number: (8513)329-0088

Technician Name: BRAN

Test Date: DEC 09-11,2013

Reviewed By/Date: ALICE I DEC 11,2013

Page 30 of36

NA

All M PASS

All

All and I or

M PASS

of 3 M PASS

NA

M PASS

M PASS

not or any loss of servicability after the application of the load. Record

NA the total amount of deformation.

Page 31: REPORT - Regent Products Corp. · (86)755-86000151 (Ext 6207 16225) John.hong@cn.bureauveritas.com Randy.huang@cn.bureauveritas.com Administrative questions, please contact: Ann An

BV Lab Number: (8513)329-0088

Technician Name: BRAN

Test Date: DEC 09-11,2013

Reviewed By/Date: BUREAU VERITAS

ALICE I DEC 11,2013

Page31 of36

XXX- 06052- NA

Effects of heat M PASS

Effects of extreme temperature change M PASS

Moisture content NA verification

TABLE I

Color I Component Location Style (mg!kg)

I BLACK PLASTIC HANDLE A <10

2 DULL BLACK PLASTIC HANDLE B <10

3 SILVERY METAL METAL PARTS A,B 15

4 DARKSILVERYMETAL HANDLE A <10

HD

Page 32: REPORT - Regent Products Corp. · (86)755-86000151 (Ext 6207 16225) John.hong@cn.bureauveritas.com Randy.huang@cn.bureauveritas.com Administrative questions, please contact: Ann An

BUREAU VERITAS

Key: * ** #

Result Key: c R M NM NA NT

Rating Kev: PASS FAIL MARG

CAR

Ima2:e Appendix G-0104 Trademark of the manufacturer or importer.bmp

HD

Additional Charge For This Test Mandatory Requirement By Request Only

Claimed Recorded Meets Does Not Meet Not Applicable Not Tested

Pass Fail Marginal Corrective Action Required

,;.-~O.f?.9.

8.~.·~ rx: . ~ '('· ~:..-·

'.f;t...... .,»' ~J,IZ:.,t;~ .. ..,.,c·

¥'-"""""'"'" ~ • .

lrii"N.G!SlO~SI:CQJ

'""''"" .·. ·#' .~-oo~"

BV Lab Number: (8513)329-0088

Technician Name: BRAN

Test Date: DEC 09-11,2013

Reviewed By/Date: ALICE I DEC 11,2013

Page 32 of36

Page 33: REPORT - Regent Products Corp. · (86)755-86000151 (Ext 6207 16225) John.hong@cn.bureauveritas.com Randy.huang@cn.bureauveritas.com Administrative questions, please contact: Ann An

BUREAU VERITAS

T-0005 Principal Display Panel.jpg

HD

P:rodl;lct N'(Ot Quanti~

Deciara!lotrmUs!JJelnE~gl~hil;ndFrench;·me!Jjc.oriils;onPDgbbld, · ~~peosiz~baserl onPOPsize · ·

., >645mrfbut <25.8di'ti' (41)0 IIJ?')

>252Sctm2 (400 ln?)

MifllmwnTvpe

2;2 mm (1 f8Jn.)

6:4 mm (1141riS

9::5rnm (3181!:0._

t2::irnm fii2In 1

BV Lab Number: (8513)329-0088

Technician Name: BRAN Test Date: DEC 09-11,2013

Reviewed By/Date: ALICE I DEC 11,2013

Page 33 of36

Client Approval: JULY 20, 2013/ Debbie Smith

Creation Date: OCTOBER 22, 2009 Last Revision Date: JULY 22, 2013 Pricing Review Date: MAY 08, 2013 Technical Review Date: !\..iA Y 08, 2013

Page 34: REPORT - Regent Products Corp. · (86)755-86000151 (Ext 6207 16225) John.hong@cn.bureauveritas.com Randy.huang@cn.bureauveritas.com Administrative questions, please contact: Ann An

BUREAU VERITAS

HD

hand tools, garden tools and kitchen utensils with grips

XXXX TEST PROTOCOL FOR XXX-06572-US

Applicable section from All samples shall be reviewed against the requirements of California

protocol CPS D-AN- Proposition 65 to determine if additional testing or labeling is required.

Santa Clara Superior Court 112CV231165/

EPA 3051A modified I CPSD-AN-00108-

MTHD

[Hand Tools, garden tools, and kitchen utensils with Grips]

Product grips of hand tools, garden tools, and kitchen utensils shall not

exceed 100 ppm (0.01 %) total lead content.

Labeling is not allowed by the consent judgment

Note:

- Composite up to 3 like materials except metal. If the composite result

exceeds the adjusted limit (regulatory limit divided by the number of

components), individual materials will be analyzed.

~ Applicable to all accessible metal, plastic and synthetic leather substrates

in the grips of single, multiple, sets or kits of hand tools, garden tools and

kitchen utensils.

-Hand tools includes wrenches, screwdrivers, pliers, hammers, saws, tape

measures, and related kits and bags as well as air blow guns, ratchet tie

downs, hand-held work-lights, flashlights, knife sharpeners, lint rollers,

bowl brushes, utility brushes, pet grooming brushes, plungers, and drain

cleaners.

-Kitchen utensils do not include cutlery such as knives, forks, spoons, or

other utensils for serving at a table.

-Vendor is responsible for compliance of all other materials.

BV Lab Number:

Technician Name:

Test Date:

Reviewed By/Date:

(8513)329-0088

DEC 09-11,2013

ALICE I DEC 11,2013

Page 34 of36

NAI-

M/PASS

SEE TABLE I

Page 35: REPORT - Regent Products Corp. · (86)755-86000151 (Ext 6207 16225) John.hong@cn.bureauveritas.com Randy.huang@cn.bureauveritas.com Administrative questions, please contact: Ann An

BUREAU VERIT!l.S

3. Phthalate content in hand tools, garden tools and kitchen utensils with grips

HD

Santa Clara Superior

Court 112CV231165 I Solvent extraction, GC­

MSILC-MS analysis I CPSD-AN-00108-

MTHD

XXX-06572-US

[Hand Tools, garden tools, and kitchen utensils with Grips]

Product grips of hand tools, garden tools, and kitchen utensils shall not

contain more than 0.1% (lOOOppm) of each ofDEHP, BBP, and DBP.

Labeling is not allowed by the consent judgment

Note: - Composite up to 3 like materials. If the composite result exceeds the

adjusted limit (regulatory limit divided by the number of components),

individual materials will be analyzed.

-Applicable to all accessible plastic and synthetic leather substrates in the

grips of single, multiple, sets or kits of hand tools, garden tools and kitchen

utensils.

~Hand tools includes wrenches, screwdrivers, pliers, hammers, saws, tape measures, and related kits and bags as well as air blow guns, ratchet tie

do'\¥11s, hand~ held work~lights, flashlights, knife sharpeners, lint rollers,

bowl brushes, utility brushes, pet grooming brushes, plungers, and drain

cleaners.

-Kitchen utensils do not include cutlery such as knives, forks, spoons, or

other utensils for serving at a table.

- Vendor is responsible for compliance of all other materials.

BV Lab Number:

Technician Name:

Test Date:

Reviewed By/Date:

(8513)329-0088

BRAN

DEC 09-11,2013

ALICE I DEC 11.2013

Page 35 of36

M/PASS

SEE TABLE2

Page 36: REPORT - Regent Products Corp. · (86)755-86000151 (Ext 6207 16225) John.hong@cn.bureauveritas.com Randy.huang@cn.bureauveritas.com Administrative questions, please contact: Ann An

BV Lab Number: (8513)329-0088

Technician Name: BRAN

Test Date: DEC 09-11,2013

BUREAU Reviewed By/Date: ALICE I DEC 11,2013

VERITAS Page 36 of36

TABLE I

Parameter UNIT Result Maximum AI1owable 1 2 3 Limit

Total Lead (Pb) mg/kg <10 <10 <10 100

CONCLUSION - PASS PASS PASS -Tested Item 1: Black plastic (handle) (A) Tested Item 2: Dull black plastic (handle) (B) Tested Item 3: Dark silvery metal (handle) (A)

TABLE2

Parameter CAS no. Unit Result Maximum Allowable

Limit 1

Dibutyl phthalate (DBP) 84-74-2 % 0.009 0.1

Butyl benzyl phthalate (BBP) 85-68-7 % <0.005 0.1

Di-2-ethylhexyl phthalate 117-81-7

% <0.005 0.1 (DEHP)

Conclusion - - PASS -

)Tested Item 1: I Black plastic (handle) (A)!/ dull black plastic (handle) (B)

HD