CSITMS Gujarat Project Confidential 1 Request for Proposals For Appointment of Agency for Design, Site Preparation, Supply, Installation and Maintenance of Physical & IT Infrastructure for the City Surveillance and Intelligent Traffic Monitoring System For Three major cities of Gujarat VOLUME - II (Technical Specifications) Bid Reference No. RFP/CCTV/CSITMS-Rev/2013/02 Home Department (GoG), Block II Sachivalaya. Gandhinagar, Gujarat (INDIA)

Upload: others

Post on 10-May-2020

3 views

Category:

Documents


0 download

TRANSCRIPT

Page 1: Request for Proposals For - Gujarat State PortalRev)22082013.pdfRequest for Proposals For Appointment of Agency for Design, Site Preparation, Supply, Installation and Maintenance of

CSITMS Gujarat Project Confidential

1

Request for Proposals

For Appointment of Agency for Design, Site

Preparation, Supply, Installation and Maintenance of Physical & IT

Infrastructure for the

City Surveillance and Intelligent Traffic Monitoring System

For Three major cities of Gujarat

VOLUME - II

(Technical Specifications)

Bid Reference No. RFP/CCTV/CSITMS-Rev/2013/02

Home Department (GoG), Block – II Sachivalaya.

Gandhinagar, Gujarat (INDIA)

Page 2: Request for Proposals For - Gujarat State PortalRev)22082013.pdfRequest for Proposals For Appointment of Agency for Design, Site Preparation, Supply, Installation and Maintenance of

CSITMS Gujarat Project Confidential

2

Volume: II

Technical Specifications

Page 3: Request for Proposals For - Gujarat State PortalRev)22082013.pdfRequest for Proposals For Appointment of Agency for Design, Site Preparation, Supply, Installation and Maintenance of

CSITMS Gujarat Project Confidential

3

Contents

1.0 General Specification and Requirement ................................................................... 5

1.1 General requirements ............................................................................................... 6

1.2 Broad details and requirements ................................................................................ 8

1.3 Inspection and Tests ................................................................................................ 10

2.0 Technical Specifications and Compliances .............................................................. 14

3.0 Network Switches & Bandwidth.............................................................................. 21

3.1 Network switch – 24 ports ...................................................................................... 21

3.2 Bandwidth ............................................................................................................... 22

4.0 Storage..................................................................................................................... 24

5.0 Video Management Software ................................................................................. 27

6.0 Video Analytics ........................................................................................................ 33

6.1 Automatic Number Plate Recognition (ANPR) ........................................................ 33

6.2 Red Light Violation Detection (RLVD) ...................................................................... 39

6.3 Manual Challan ........................................................................................................ 43

7.0 Data Center.............................................................................................................. 45

7.1 Air conditioners ....................................................................................................... 45

7.2 UPS........................................................................................................................... 50

7.3 Access control system ............................................................................................. 55

7.4 Fire detection and suppression ............................................................................... 63

7.5 Internal CCTV system .............................................................................................. 87

8.0 City wise Command and Control Centre ................................................................. 88

8.1 Workstation ............................................................................................................. 88

8.2 USB Joystick ............................................................................................................. 89

8.3 Server ....................................................................................................................... 89

8.4 Video Wall (3 X 4) .................................................................................................... 91

Page 4: Request for Proposals For - Gujarat State PortalRev)22082013.pdfRequest for Proposals For Appointment of Agency for Design, Site Preparation, Supply, Installation and Maintenance of

CSITMS Gujarat Project Confidential

4

8.5 Furniture .................................................................................................................. 93

9.0 UPS and DG set ........................................................................................................ 95

9.1 6 KVA UPS ................................................................................................................ 95

9.2 DG set ...................................................................................................................... 97

10.0 Firewall / UTM Specifications ................................................................................ 102

11.0 Antivirus Specifications ......................................................................................... 107

12.0 NMS Specifications ................................................................................................ 116

13.0 Multifunctional Printer .......................................................................................... 118

Annexure – I Approved Make ..................................................................................... 119

Page 5: Request for Proposals For - Gujarat State PortalRev)22082013.pdfRequest for Proposals For Appointment of Agency for Design, Site Preparation, Supply, Installation and Maintenance of

CSITMS Gujarat Project Confidential

5

1.0 General Specification and Requirement

The purpose of this project is to create a safe and secure environment for the citizens

who live, work, visit and doing business in Ahmedabad, Vadodara & Gandhinagar city by:

Reducing the fear of crime and reassuring the public

Helping to prevent crime

Deterring and detecting crime

Helping to identify, apprehend and prosecute offenders

Providing evidence for criminal and civil action in the courts

Helping maintain public order

Assisting in the management and policing of large-scale events

Providing assistance to emergency services

Assisting in improving traffic discipline and the town environment

The broad scope of the project is to install IP based Surveillance System &

Traffic Solution at strategic locations, entry / exits, traffic junctions of Ahmedabad,

Vadodara & Gandhinagar City to provide security to the citizens.

At all the locations the work is to be executed carefully, ensuring that the other areas of

premises and nearby services are not disturbed and cleanliness shall be maintained at all

the time during project execution. There should be a City Command & Control Room at

respective CP offices for monitoring & storage.

The video feed from the individual fixed and PTZ camera, alerts from ANPR, RLVD system

should reach to network switch at the location and from the network switch through

fiber connectivity it should be transmitted to City Command & Control room. There shall

be UPS installed with 4 Hrs. of backup at field and at City Command & Control Room to

cater the power backup facility for equipments during the period of outage of the power.

More over at certain location where the street light and other related illumination is not

adequate, external IR illuminator shall be installed to capture the video footage during

the night / low lux environment.

One traffic junctions Viz. Income tax will contain Automatic Number Plate Reading

(ANPR) and Red Light Violated Detection (RLVD) system. One City Entry / exit point at

Page 6: Request for Proposals For - Gujarat State PortalRev)22082013.pdfRequest for Proposals For Appointment of Agency for Design, Site Preparation, Supply, Installation and Maintenance of

CSITMS Gujarat Project Confidential

6

Narol Junction will have ANPR. The data processing will be done locally but only alerts

with relevant images will be sent to city wise control room and challan (Automatic /

Manual) will be generated.

1.1 General requirements

a) Equipment, devices and materials used should be as per Industry standards.

Workmanship and installation of devices should consider proper installation;

connecting and testing all points related to IP based CCTV & Traffic System for all

the locations mentioned in this RFP. Co-ordination with other agencies for other

sub systems installed in the Command & Control Centre is to be taken care of like

Civil, Electrical, UPS, furniture etc.

Page 7: Request for Proposals For - Gujarat State PortalRev)22082013.pdfRequest for Proposals For Appointment of Agency for Design, Site Preparation, Supply, Installation and Maintenance of

CSITMS Gujarat Project Confidential

7

b) Care is to be taken considering service & maintenance for the period of five years

of various systems and necessary provisions shall be made at desired places for sub

systems.

c) Usage of materials as mentioned is to be strictly adhered to.

d) Team of Skilled manpower is to be deployed during project implementation

under trained supervisor at site. A detail list of qualifications and No. of persons has

to be submitted with the bid.

e) Wherever possible; efficient & sturdy structure, usage of trays, necessary

accessories and bends etc should be used and work shall be completed on time at

all stages of the Project.

The response to RFP must include/ensure the following:

1. Detailed description of materials proposed in accordance with the requirement

statement.

2. Compliance must be ensured to all the Technical Specifications / makes / etc. spelt

out in this RFP must be ensured.

3. Comprehensive Bill of Quantity with identification numbers, sizes, specifications

and quantity for materials to be used must be provided.

4. Wherever required design/layout should be provided for each section.

5. Bidder should keep sufficient spares of the key components at the local office for

7 years from FAT.

6. Timely completion of the work including at each project stage is essential.

7. Bidder must provide write-up, pictures etc as documentary proof of quality work

executed.

8. Any special skill, list of tools or other important information may be provided,

which can explain qualitative expertise of the Bidder for this project.

Page 8: Request for Proposals For - Gujarat State PortalRev)22082013.pdfRequest for Proposals For Appointment of Agency for Design, Site Preparation, Supply, Installation and Maintenance of

CSITMS Gujarat Project Confidential

8

9. The work is to be carried out as per Industry standard and specific needs of an IP

based CCTV project, Traffic Solution & Control Room.

1.2 Broad details and requirements

Bidder shall carry out supply, installation, testing, commissioning, manage and run all

systems / subsystems for CSITMS PROJECT IN THREE CITIES OF GUJARAT for 5 years

after FAT. The list of locations of CSITMS Project for Ahmedabad, Vadodara and

Gandhinagar is mentioned in the RFP. Such work shall be executed as per the

National and International standards, the best industry practices and Vendor’s

standard practice/documentation and recommendations. The bidder has to take care

of transport, lifting and shifting of the all the equipments at the respective sites.

At all the locations the work is to be executed carefully, ensuring that the other areas

of premises and nearby services are not disturbed and cleanliness shall be

maintained at all the time during project execution.

1.2.1 Bidder shall carry out the work including necessary co-ordination and integration

to many other systems to be installed for the CSITMS Project :

a) The Bidder should ensure that the work is carried out as per the specification

using material from reputed manufacturer.

b) The Bidder and his OEM shall work in coordination to resolve the issues related to

interoperability problem with any other equipment/solution during the

implementation of the solution.

c) While bringing the equipment, ensure customer assets are not damaged due to

usage of cranes, trucks for material movement.

1.2.2 The Bidder should supply all necessary accessories required to install the various

subsystems to commission and integrate the equipment/solutions for CSITMS

project.

Page 9: Request for Proposals For - Gujarat State PortalRev)22082013.pdfRequest for Proposals For Appointment of Agency for Design, Site Preparation, Supply, Installation and Maintenance of

CSITMS Gujarat Project Confidential

9

1.2.3 The Bidder along with (n)Code Solutions – A Division of GNFC Ltd. shall conduct

the inspection & testing of all equipments / materials at the time of delivery and

after implementation and commissioning.

1.2.4 The warranty shall be comprehensive in nature i.e. shall include components

replacement/ repairing of material, equipments / solution, software free of cost

and all expenses incurred on the replacement /repairing/standby shall be borne

by the Bidder.

1.2.5 The terms and the time period of the warranty should be as per the specifications

given separately under the heading of “Warranty”.

1.2.6 Timely availability of the materials at site shall be ensured & the work is to be

carried out by skilled manpower

1.2.7 Bidder shall provide spares and service support as mentioned under. Bidder to

provide information and organization set up for the spares and service support

offered by them.

a. The Bidder shall agree to supply the spares for a period of seven years

after the date of Final Acceptance Certificate at the same or less price

( provide such list with current rates ).

b. The Bidder or its OEM shall stock all necessary spare parts available

with them for the replacement / rectification of problems and must be

used so as to rectify the faults at the all the locations of Ahmedabad ,

Vadodara & Gandhinagar City within the time limit specified in tender.

1.2.8 The Bidder shall clearly describe what other technical services, assistance, training

or support will be provided to Home Department - GoG to deploy the proposed

solution.

1.2.9 The Bidder should have their Sales & Service arrangement to be able to provide

Offsite / Onsite 24 X 7 hours support at the locations of Ahmedabad, Vadodara &

Gandhinagar city.

Page 10: Request for Proposals For - Gujarat State PortalRev)22082013.pdfRequest for Proposals For Appointment of Agency for Design, Site Preparation, Supply, Installation and Maintenance of

CSITMS Gujarat Project Confidential

10

1.3 Inspection and Tests

The inspection and tests shall be conducted at the installation locations of all the

three cities i.e. Ahmedabad, Vadodara & Gandhinagar.

a) The inspection and tests shall be conducted at the installation premises. The

Bidder / OEM shall provide all necessary facilities and equipments including access

to drawings, datasheet, architecture, programming manual, software etc required

to carry out such tests.

The Bidder shall provide inspection and testing from EQDC for the equipment

before the delivery.

b) The Bidder shall provide the following things as minimum before the delivery of

the Equipment.

Factory test reports

Identification of the equipment being delivered

Bill of Quantity along with detailed specifications and quantity

All the documentation in hard/soft copy, required for the successful

installation and commissioning of the equipment for the project.

c) On site Test shall include testing of all equipments for the acceptance level of

various parameters for system reliability, availability and maintainability. The

Bidder shall broadly include/submit a comprehensive write up to cover the

performance test as proposed to be conducted. The intent of the performance

shall be to demonstrate that the proposed system performs all the functions as

indicated in the Specification sheets correctly and reliably and as per the

requirement mentioned in tender.

d) The write up/ procedure for performance test shall be subjected to (n)Code

Solutions – A Division of GNFC Ltd ‘s approval. The availability tests shall include

all reasonable exercises with which the combination of equipment and software

can be expected to perform in actual usage.

e) Inspection Tests for Components:

Confirm on the components with the Packing list & Purchase Order.

Check for internal/ external damages.

Check for appropriate Power conditions.

Page 11: Request for Proposals For - Gujarat State PortalRev)22082013.pdfRequest for Proposals For Appointment of Agency for Design, Site Preparation, Supply, Installation and Maintenance of

CSITMS Gujarat Project Confidential

11

Verify if the equipment and accessories are as per the list provided by

the Bidder.

Demonstration of working conditions of Equipment’s Functionality.

EQDC test report for supplied equipments

f) Inspection Tests for completely integrated system:

Physical inspection

Verification of contents as provided by the Bidder in response to this

RFP.

Verification of documentation as provided in softcopy and/or

hardcopy format.

Demonstration of the proper functioning of all devices to be deployed

as per the specifications.

Tests shall be carried out as per applicable material standards and

specifications mentioned in RFP.

Bidder shall provide life of goods supplied and version of goods

supplied.

g) Post Implementation

Integrated Test Plans should include the following as minimum:

Should any inspected or tested equipment/solution fail to confirm to the

specifications, Home department - GoG may reject it and the Bidder shall

replace the rejected goods or make all alterations necessary to meet the

requirements of specifications, free of cost to Home department - GoG within

two days.

The Bidder shall also furnish the reference documents/standards etc. as

referred in quality plans along with the quality plans.

In case the equipment is assembled at the time of commissioning then these

equipments shall be tested post implementation of the equipment/solution.

h) Service Level Requirements

Warranty/AMC involves comprehensive maintenance and repairs of all items,

equipments for the work executed, including free of cost replacement of

Page 12: Request for Proposals For - Gujarat State PortalRev)22082013.pdfRequest for Proposals For Appointment of Agency for Design, Site Preparation, Supply, Installation and Maintenance of

CSITMS Gujarat Project Confidential

12

parts, consumables if any, modules, sub-modules, assemblies, sub-assemblies,

spares, parts, to make the system operational. Provide OEM warranty

Guarantee cards etc. arrange immediate delivery of consumables/spare

during Warranty/AMC period.

i) MAINTENANCE:

The material supplied shall have warranty of 5 years from the date of

completion of installation, testing and commissioning of the systems.

Warranty involves comprehensive maintenance and repairs of material for

the installed material, including free of cost replacement of parts,

consumables if any, modules, sub-modules, assemblies, sub-assemblies,

spares, to make the system operational.

j) Manufacturer’s Technical Data

Manufacturer's performance data, certified factory drawings of apparatus

giving full information as to capacity, dimensions, serial number, materials

and all information pertinent to the adequacy of the submitted equipment

shall be submitted for approval. Manufacturers’ names, sizes, catalogue

numbers and/or samples of all materials shall be submitted for approval.

Submittals and drawings should, as far as possible be complementary so that

drawings and submittals can be crosschecked.

Requirements for Equipment submitted for approval must be accompanied by

relevant drawings, technical data, catalogues and samples. Where data

certified drawings or other required information is not available until after

orders have been placed, Project-in-charge will give provisional approval until

all requested drawings and information have been supplied to the PROJECT-

IN-CHARGE and approved by him. It is Contractor's responsibility to ensure

that all necessary information is supplied to the PROJECT-IN-CHARGE in

accordance with the progress of the work.

k) Proprietary Materials

Proprietary materials to be used in the works, shall, when brought to site be

got inspected by the PROJECT-IN-CHARGE.

Page 13: Request for Proposals For - Gujarat State PortalRev)22082013.pdfRequest for Proposals For Appointment of Agency for Design, Site Preparation, Supply, Installation and Maintenance of

CSITMS Gujarat Project Confidential

13

Proprietary materials brought to site shall be stored as per recommendation

of the manufacturer and as directed by the PROJECT-IN-CHARGE.

The Contractor shall, on demand, produce to the PROJECT-IN-CHARGE any

document / proof of purchase in respect of the supplies.

The Contractor shall ensure that the materials are brought to site in original

sealed containers/ packing bearing manufacturer's markings.

Page 14: Request for Proposals For - Gujarat State PortalRev)22082013.pdfRequest for Proposals For Appointment of Agency for Design, Site Preparation, Supply, Installation and Maintenance of

CSITMS Gujarat Project Confidential

14

2.0 Technical Specifications and Compliances

2.1 Fixed IP 2 MP Outdoor Camera

Specifications

Image sensor 1 / 3” CCD / CMOS Progressive Scan (2 MP)

Electronic Shutter 1 to 1 / 10,000 s

Min illumination/ light sensitivity (Color) 2 lux (30 IRE, F 1.2)

Min illumination/ light sensitivity (B/W) 0.5 lux (30 IRE, F 1.2)

Wide Dynamic Range Required

Backlight Compensation ON/OFF

IRIS Control DC or Automatic

Focus Automatic / Manual

Automatic Gain Control Auto / Manual

Color, Brightness, Contrast functionality Required

Frame Rate 25 FPS for 1920 x 1080

Varifocal Lens 2.8 – 12mm varifocal lens

Video

Day and Night functionality Automatic, Color, Mono

Video Resolution 2 MP (1920 x 1080)

Video Streams Individually configurable 02 video streams (H.264, MJPEG)

Intelligent Video Motion detection

Compression

MJPEG Required

H.264 Required

Audio

Audio support Required

Audio Compression G.711 or better

Page 15: Request for Proposals For - Gujarat State PortalRev)22082013.pdfRequest for Proposals For Appointment of Agency for Design, Site Preparation, Supply, Installation and Maintenance of

CSITMS Gujarat Project Confidential

15

Two-way audio Required

Input / Output 01 IN & 01 OUT

Network & Interface

Interface RJ-45 for 10/100 base-T Ethernet

I/O Port 01 IN, 01 OUT

Upgrade Through web browser , online, firmware upgrade

Network Protocols support TCP/IP, HTTP, ICMP, PPPoE, DDNS, DHCP, UDP, DNS, SMTP, RTP, RTSP, SNMP protocols

Alarm Event

Events / alerts send via FTP, HTTP, email,

Pre-Post alarm video buffering.

Compliance ONVIF

Security

Password Protection Required

HTTPS encryption Required

IEEE 802.1X Required

General

Operational temperature °C 0°C to 50 °C

Humidity 0 to 80% RH non-condensing

IP rating IP66, NEMA 4X Rated Outdoor Housing

Power PoE, AC24V/ DC12V, 100- 230VAC

Certifications CE, UL/EN, FCC

Page 16: Request for Proposals For - Gujarat State PortalRev)22082013.pdfRequest for Proposals For Appointment of Agency for Design, Site Preparation, Supply, Installation and Maintenance of

CSITMS Gujarat Project Confidential

16

2.2 PTZ IP, 2MP, 18x Outdoor Camera

Specifications

Image sensor 1 / 3” CCD / CMOS Progressive Scan (2 MP)

Focal Length 4.7 to 84.6 mm

Zoom 18x Optical & 10x Digital

Electronic Shutter 1 to 1 / 10,000 s

Min illumination/ light sensitivity (Color) 2 lux (30 IRE, F 1.6)

Min illumination/ light sensitivity (B/W) 0.5 lux (30 IRE, F 1.6)

Wide Dynamic Range Required

Backlight Compensation ON/OFF

IRIS Control DC or Automatic

Focus Automatic / Manual

Automatic Gain Control Auto / Manual

Color, Brightness, Contrast functionality Required

Frame Rate 25 FPS for 1920 x 1080

Video

Day and Night functionality Automatic, Color, Mono

Video Resolution 2 MP (1920 x 1080)

Video Streams Individually configurable 02 video streams (H.264, MJPEG)

Intelligent Video Motion detection

Electronic Image Stabilization Required

PTZ Function

PAN TILT Range 360° continuous pan & 180° tilt range

PAN TILT Speed 280° / sec for panning &

Page 17: Request for Proposals For - Gujarat State PortalRev)22082013.pdfRequest for Proposals For Appointment of Agency for Design, Site Preparation, Supply, Installation and Maintenance of

CSITMS Gujarat Project Confidential

17

160° / sec for tilting

Presets 64 Preset Points

Tour & Pattern Required

Privacy Mask 04 Zones

Compression

MJPEG Required

H.264 Required

Audio

Audio support Required

Audio Compression G.711 or better

Two-way audio Required

Input / Output 01 IN & 01 OUT

Network & Interface

Interface RJ-45 for 10/100 base-T Ethernet

I/O Port 01 IN, 01 OUT

Upgrade Through web browser , online, firmware upgrade

Network Protocols support TCP/IP, HTTP, ICMP, PPPoE, DDNS, DHCP, UDP, DNS, SMTP, RTP, RTSP, SNMP protocols

Alarm Event

Events / alerts send via FTP, HTTP, email,

Pre-Post alarm video buffering.

Compliance ONVIF

Security

Password Protection Required

HTTPS encryption Required

IEEE 802.1X Required

General

Operational temperature °C 0°C to 50 °C

Humidity 0 to 80% RH non-condensing

IP rating IP66, NEMA 4X Rated Outdoor Housing

Power AC24V/ DC12V, 100- 230VAC

Page 18: Request for Proposals For - Gujarat State PortalRev)22082013.pdfRequest for Proposals For Appointment of Agency for Design, Site Preparation, Supply, Installation and Maintenance of

CSITMS Gujarat Project Confidential

18

Certifications CE, UL/EN, FCC

2.3 Outdoor IP55 Enclosure

Outdoor IP 55 enclosure with Air conditioner

Dimensions (mm) The Overall dimension of cabinet should not exceed 80W X

1300H X 600D.

Enclosure Outdoor IP55 Enclosure. Condensate discharge plug to be

provided inside the enclosure to prevent condensation.

Load carrying capacity

(Kgs.) 1000

Plinth height (mm) 100

Doors and locking system

Front and rear 2 mm thick sheet steel door with PU Foamed

Seal (Gasketing) with removable galvanized rectangular

frame with holes on a 25 mm DIN pitch pattern with 3 point

locking system.

The hinges and retainers should be made of die cast, copper

nickel chrome plated with SS hinge pins. The doors should

be swapped to LH if required with door opening angle 130

deg to VDI.

Top panel made of 1.5 mm thick sheet steel with PU foamed

(Gasketing) boltable from inside.

Panel Sizes (mm.)

Bottom panel made of 1.5 mm thick sheet steel with PU

foamed (Gasketing) with provision for fixing 4 nos of PG 29

glands.

Side panels in double walled construction with air gap of

minimum 20 mm between two walls with PU

foamed(Gasketing) for IP 55 protection

Regulatory Compliances IP55 to EN60529/09.2000, ISO 9001, 14001, 18001 comply

with EIA 310, DIN 41494 and IEC 297 standards.

Page 19: Request for Proposals For - Gujarat State PortalRev)22082013.pdfRequest for Proposals For Appointment of Agency for Design, Site Preparation, Supply, Installation and Maintenance of

CSITMS Gujarat Project Confidential

19

Painting

The cabinet has to be nano ceramic coated, Electro phoretic

(EC) dipcoat priming to 20 Microns and then powder coated

to RAL 7035 textured Pure Polyester (PP) to 80 to 120

Microns.

Rain Canopy Height (mm) 75

Universal sockets One 19” mountable socket strip with 4 nos of 5/15A

universal sockets

Angles

2 pairs of L type 19” angles to be provided at front and rear

for mounting the equipments on 23X73 (maxim) punched

sections:

Earthing Earthing to be done for the entire cabinet with 4 sq mm

earthing cables.

Cantilever Shelf One 1U cantilever shelf of 250 mm deep.

Cable Manager 2 Horizontal 1U cable manager with 5 nos of plastic cable

loops.

Limit Switches 2 Door Operated limit switch to be provided at front and

rear door.

Hardware Captive hardware (pack of 20): 1 pack.

For Front and rear door 4 Ergoform S handles with key insert and pad locking

arrangement for front and rear door

Cable Entry PG 29 glands to be provided at the bottom for cable entry

2.4 Outdoor Cooling Unit (Part of the outdoor enclosure with Air conditioning)

Sr.

No.

Description Specification

Cooling unit output 1400 Watts at L35L35

1100 Watts at L35L50

1 Rated operating voltage 230V/50/60 Hz

2 Dimensions of cooling unit Vendor to specify

3 Rated current Vendor to specify

4 Start up current Vendor to specify

5 Power consumption Vendor to specify

6 Refrigeration Factor Vendor to specify

7 Refrigerant R-134 a Gas

Page 20: Request for Proposals For - Gujarat State PortalRev)22082013.pdfRequest for Proposals For Appointment of Agency for Design, Site Preparation, Supply, Installation and Maintenance of

CSITMS Gujarat Project Confidential

20

8 Weight Vendor to specify

9 Permissible operating pressure 24 bar

10 Temperature range +20ºc to +55ºc

11 Duty cycle 100%

12 Protection category to EN

60529/10.91 IP 55 Internal circuit

13 Type of connection Vendor to specify

14 Colour Vendor to specify

15 Temperature control +20ºc to +55ºc, Factory set 35 ºc.

16 Internal Fan Required

17 External Fan Required

18 Expansion valve Required

19 Copper tubes Required

Page 21: Request for Proposals For - Gujarat State PortalRev)22082013.pdfRequest for Proposals For Appointment of Agency for Design, Site Preparation, Supply, Installation and Maintenance of

CSITMS Gujarat Project Confidential

21

3.0 Network Switches & Bandwidth

3.1 Network switch – 24 ports

Architecture

General Requirements: Switch should be rack mountable

Switch should have non-blocking architecture

Switch should have total 24 nos. of 10/100/1000BaseT Interfaces with additional 4xGigabit uplink ports

Switch Should offer option for Redundant Power Supply (RPS) if required

Switch should support Auto MDI/MDIX and stacking feature with required stack cables

Switch should support TDR for detecting cable breaks and shorts

Performance Requirements ; Switch should have minimum 80Gbps Data switching capacity

Switch should have minimum 60 Mpps L2 throughput

Layer-2 Requirements

Switch should support minimum 10000 MAC address

Switch should support Jumbo Frames & minimum 1000 vlans

Switch should support 802.1q VLAN tagging & Voice VLAN

Switch should support link aggregation for minimum 4 ports

Layer-3 Requirements

Should support - static IP routing, RIP-1, RIP-2, RIPng,, OSPF, BGP-4, OSPFv3, IS-ISv6, and BGP4+ for IPv6

Should support IPv6 L2 and L3 features as well as IPv6 tunneling mechanism

Should support Policy based Routing

Should support Equal-Cost Multipath (ECMP) to enable multiple equal-cost links in routing environment to increase link redundancy and scale bandwidth or equivalent feature.

Security Requirements

Should support Access control lists to provide L2 to L4 traffic filtering for IPv4 and IPv6 Packets by offering Standard ACL, Extended ACL, VLAN ACL, Port based ACL, and Time based ACL

Should support MAC, 802.1x and Web based authentication, with multiple authentication method and concurrent authentication session per port minimum for 80 Users per port.

Page 22: Request for Proposals For - Gujarat State PortalRev)22082013.pdfRequest for Proposals For Appointment of Agency for Design, Site Preparation, Supply, Installation and Maintenance of

CSITMS Gujarat Project Confidential

22

Should support Full Network Access Control features to push Dynamic Vlan and Port based profile to the user ports based on the AAA, LDAP, AD, Radius server authenticated response.

Should support Guest Vlan, and should restrict access to specific users or devices based on MAC address learned or statically defined.

Should support BPDU port protection, Root Guard, DHCP ARP protection, IP Source Guard, and Unicast Reverse Path Forwarding URPF features.

Supports DoS-DDoS protection, Storm Control

QoS Requirements

Support IGMPv1, v2, and v3, PIM-SM / DM, PIM-SSM, Multicast Source Discovery Protocol, Multicast Vlan

Support congestion control mechanism

Management Requirements

Should support encrypted communication between the user accessing the device namely using all access methods CLI, GUI, or NMS via features like SSHv2, SSL, and SNMPv3 and Secure FTP/TFTP etc.

Should support features like CDP, LLDP, LLDP-MED

Link activity, port transmission speed, port duplex mode, power, link OK, system etc

Should support Debugging via cli via console, telnet, ssh

Switch should support Traffic mirroring (port, vlan)

ACL-based mirroring

IP tools (e.g. Ping, extended Ping, extended Trace)

3.2 Bandwidth

Bidder shall supply the required hardware, software and accessories for bandwidth. Such work shall be executed as per the National and International standards, the best industry practices and Vendor’s standard practice/documentation and recommendations.

The Bidder should supply all necessary cables/items/Interface converters etc. to commission and integrate the equipment supplied for internet bandwidth. Internet bandwidth of 10Mbps should be considered for Control Center or Data center location(s) only.

The Bidder should sign an SLA of 99.5% uptime of bandwidth supply with Home Department - GoG

Page 23: Request for Proposals For - Gujarat State PortalRev)22082013.pdfRequest for Proposals For Appointment of Agency for Design, Site Preparation, Supply, Installation and Maintenance of

CSITMS Gujarat Project Confidential

23

Sr. No.

Item Description

1 Media Must be on fiber/Ethernet media with the SLA of 99.5% uptime

2 Media converters

In case of fiber, the same should be converted to Ethernet media. SLA of 99.5% uptime will be applicable on all accessories in such case.

3

Connectivity with other service providers

Must ensure availability of enough free bandwidth between other local service providers such as Tata, Airtel, Reliance, BSNL, Aircel , Vodafone, etc. (Applicable only for internet bandwidth)

4 Indian sites accessibility

The ping or trace result for any Indian region sites must be reachable within <50ms or to the entry point of the said service provider (Applicable only for internet bandwidth)

5 Any other sites accessibility

The ping or trace result for any other sites must be reachable within <80ms or to the entry point of the said service provider

6 Other

The reach ability from BSNL and/or such other broad band connections must be within 80‐100 ms so as our services across Gujarat and India should not face any issue of unavailability of our servers/services hosted on vendor IP network (Applicable only for internet bandwidth)

7 IP Address IPv4 & IPv6 must be supported. Minimum 32 usable real/public IPs of IPv4 should be provided. (Applicable only for internet bandwidth)

8 Proactive Monitoring

Vendor should ensure proactive monitoring of the bandwidth and must inform (n)Code Solutions between 7:00 AM to 11:00 PM within 5 minutes of any fault detected in the bandwidth. In case of any unusual observations like high or low traffic pattern bandwidth usage compared to routine bandwidth usage, packet loss, etc.; then it must be brought to the notice of concern person at customer end. During night time between 11:00PM to 7:00AM, such updates/alerts should be sent via mail.

9 Reports Weekly reports should be submitted towards 99.9% uptime of bandwidth on the first day of each week by 15:00.

For field locations no internet bandwidth is required but adequate bandwidth should be

provided for all cameras feed transmitting to CC/DC.

Page 24: Request for Proposals For - Gujarat State PortalRev)22082013.pdfRequest for Proposals For Appointment of Agency for Design, Site Preparation, Supply, Installation and Maintenance of

CSITMS Gujarat Project Confidential

24

4.0 Storage

Features Description

Storage Architecture The Storage System should be with NSPoF (No single point of failure). The architecture should allow modular upgrades of hardware and software. Must support load balancing at the controller level between multiple similar storage arrays. Storage solution should have Truly distributed fully symmetric clustered architecture. Should support latest technology SSD, SAS, NL-SAS/SATA Drives

Capacity expansion with no Data Migrations

There should not be any downtime or migration activity required in the event it is needed to add additional capacity or additional performance to the storage system. Storage solution should enable independent and linear scalability of performance and capacity. In the event of storage up gradation, existing data should be rebalanced across all storage controllers/disks etc. This auto balance should be done with low priority avoiding any impact to performance.

Cache Protection Cache should be protected through cache protection mechanism like mirroring, de-staging, coherency etc.

Storage Operating System

Storage System should have Fully journaled, fully distributed, specialized Operating System, dedicated for serving data optimally, efficiently and customized for Storage.

Type of Storage System and

Protocols support

The Storage System can be either NAS or IP SAN or FC SAN suiting the VMS Application Network protocol Support: CIFS / NFS Version 3 and 4, SNMP, Network time protocol (NTP), HTTP, FTP/ iSCSI, NDMP

Front-end Ports & Back plane

Should support minimum 4 X 1 Gb Ethernet front end ports per controller. Should also support 10 Gb Ethernet (optional 8Gbps FC).

Scalability All components of the storage system architecture must support scaling to provide continuous growth to meet the growing demand of Gujarat Police. The system should support vertical / horizontal scalability so that depending on the changing requirement from time to time system can be scaled. There must not be any system imposed restrictions on upward scalability of number of IP Camera’s.

Open Architecture Storage Solution to be configured with minimum 16GB cache / memory per controller with protection mechanism. Additional Controllers should have their own cache equal to or greater than 16GB each.

Page 25: Request for Proposals For - Gujarat State PortalRev)22082013.pdfRequest for Proposals For Appointment of Agency for Design, Site Preparation, Supply, Installation and Maintenance of

CSITMS Gujarat Project Confidential

25

Storage Capacity Shall provide 750 TB of useable disk space under RAID 6 or equivalent protection with hot spare disk per Shelf, using 3TB/4TB 7.2K RPM NL-SAS or SATA-II Disks. Must support online expansion of RAID Group. Bidder should clearly specify number of RAID groups, RAID group size and the total number of disks considered for the RAID group size.

Storage Scalability The storage system should be scalable to double the capacity of the original/initial usable space without replacement of the controllers etc. Must be able to add additional disks on the fly to expand the RAID group capacity. Intelligently restripe data/ expanding the file system as disks are added to optimize the performance and no additional licence for the same should be required.

RAID Rebuild times on disk failures

Should not take more than 24 hrs to rebuild failed disk(s).

Performance Guarantee

The certificate, on OEM's letterhead, of performance/throughput figures, for the offered configuration of Storage Solution, needs to be given by the OEM along with the technical proposal itself.

In case of any component failure, system should not have more than 20% impact to system performance which needs to be demonstrated as part of User Acceptance Test.

Standard Software Features & Product

Lifecycle Support

Integrated automatic RAID Manager, alerts, DNS, SNMP. Automatic error reporting via SMTP email to global support center.

The Proposed Storage should not be declared for End of Life for the next 5 yrs and OEM confirmation on their letter head should be attached.

Should support snapshot feature and only one time licence should be applicable for any future expansion also. If any of the features mentioned / offered requires license the same should be included as part of the BOM.

Firmware should be upgradeable for functionality improvement and enhancements. Must support non-disruptive upgrade.

RAID Support Should support RAID 0,1, 5, 6 or equivalent

OS Support Shall support Windows server 2003 & 2008, Red hat Linux, HP-UX, SUN Solaris, Suse Linux, Vmware, Windows XP/7 etc. All requisite licenses for these operating systems shall be provided.

Storage Management & Security

Management software for performance monitoring to be provided along with the storage hardware with Web GUI & CLI interface. The storage system shall be configured with GUI based management software to provide minimum following functionality:

•Monitor status and health of storage and manage the storage solution

•Storage performance, throughput, network connections etc

Page 26: Request for Proposals For - Gujarat State PortalRev)22082013.pdfRequest for Proposals For Appointment of Agency for Design, Site Preparation, Supply, Installation and Maintenance of

CSITMS Gujarat Project Confidential

26

monitoring

•Folder and File Level Access Control Lists (ACL) security for users & groups.

•Should support user security mechanisms like AD,LDAP / NIS.

Other Features Should support minimum 512 CIFS/NFS shares. This capability should be at minimum doubled with the addition of one more pair of (clustered) controllers in the future. should support quota and minimum 512 quota rules with support for 50,000 user quota rules per system

Page 27: Request for Proposals For - Gujarat State PortalRev)22082013.pdfRequest for Proposals For Appointment of Agency for Design, Site Preparation, Supply, Installation and Maintenance of

CSITMS Gujarat Project Confidential

27

5.0 Video Management Software

1.

The system should be easy to install, learn, operate and manage: The VMS shall have rich user interface that provides one-click access, drag-drop, context menu, shortcut keys, customizable GUI etc to enhance operational efficiently in daily tasks and maintain The VMS shall have ability to respond fast & shall be applicable to all processes, functions, features, and screens of a video management system.

2. Simple, clear documentation including User Guides (how to use the product) and Technical Reference Manuals (quick reference on functions and procedures) shall be submitted

3.

Scalability: The VMS shall have ability to connect and integrate other technologies and third party software systems (e.g. ANPR, RLVD) and act as a cohesive platform for entire surveillance and security system. The system should be able to bi-directionally and dynamically exchange data between various software applications in real-time as well as schedule transfer. The Software shall be scalable upto 10 times minimum. Support for unlimited cameras, servers, sites and clients. Support for storage expandability. Well documented Software Development Kit (SDK): The SDK should include a rich, easy-to-use Application Programming Interface (API) that supports the most common programming languages. Input and output support: The VMS shall have ability to receive and accumulate inputs from external hardware/software and respond and activate outputs based on the predefined rules. Event management: The VMS shall have ability to enforce custom settings for event detection, alarm notification, recording, input/out (I/O) control, and other features in response to events. The alarm management module shall support graphical displays with interactive icons to display the status of the cameras & other inputs. Support for standard protocols: The VMS shall have ability to maintain independence from any one vendor & shall support open standard protocol i.e. ONVIF

4.

Smooth software upgrade path for support of new devices, drivers and operating systems. System should be able to implement software upgrades without requiring all hardware components to be reconfigured. System should provide Database Server Redundancy options, Camera Server Redundancy options, and automatic fault tolerance for robust system uptime and Distributed database and video storage.

5. On screen help and instructions: The system should provide context-sensitive

Page 28: Request for Proposals For - Gujarat State PortalRev)22082013.pdfRequest for Proposals For Appointment of Agency for Design, Site Preparation, Supply, Installation and Maintenance of

CSITMS Gujarat Project Confidential

28

help and active assistance based on the module / screen / operations a user is trying view or perform. As the user moves around the interface, the help should automatically changes to the relevant field-level help topic.

6. User management with user groups, roles, privileges and access policies (assigned views, PTZ priority, access to video wall etc)

7. Integration with LDAP/AD users and policies

8. Centrally controlled user management - Users, roles, rules and privileges should be stored on the central VMS server allowing any authorized user to log into any workstation.

9.

Recording Server :

The System shall not restrict the number of recording servers

Shall support dual streaming

Shall allow each stream to be viewed independently by client viewer.

Recording from connected cameras shall be stored in individual databases.

Shall support multiple storage formats

Shall support recording in all resolution at desired FPS

Shall support audio recording

10.

The VMS shall have ability to push a single command or configuration to multiple users with a single “Click”. This can be done though a GUI where access privileges and other parameters can be applied to multiple users or user-groups.

11. Support for Motion Exclusion Zones to enhances optimized recordings and storage.

12. Configurable data aging mechanism to automatically compress older recordings in lower frame rates to enhance storage.

13. Customizable recording retention period for specific camera, group, area etc.

14. Remote Users : Should support at least 10 remote users via network/web browser/client software

15. Automatic check & update of hardware drivers & firmware free of cost

16. The VMS shall have Electronic Image Stabilization feature

17. Support and configuration options for virtual matrix.

18. Copy or Clone option to install new device based on already configured device and template based batch administration option.

19. The VMS shall have ability to easily install, configure, modify, search and remove surveillance devices with automatic discovery of IP devices.

20. Advanced option to install other devices like Analog cameras, encoders, microphone-speakers, access control devices, digital message boards etc.

21. The VMS shall have ability to logically group devices based on installation location, device type, configuration type or any other predefined rules. Individual cameras/devices should inherited rules from parent

Page 29: Request for Proposals For - Gujarat State PortalRev)22082013.pdfRequest for Proposals For Appointment of Agency for Design, Site Preparation, Supply, Installation and Maintenance of

CSITMS Gujarat Project Confidential

29

group/subgroup.

22. The VMS shall have ability to search and view device(s) based on standard criteria like ID, Name, Location, Group, Type etc.

23. The VMS shall have ability to enforce access privileges (View /Add /Edit/ Remove) to device(s) or group(s).

24.

The VMS shall have ability to draw and configure e-map of surveillance facility, choose back-ground images, User-definable symbols (for deployed devices)and programmable functions, e.g. hyperlinks, controlling video feed, initialing alarms etc

25. Automatic firmware updates notifications and wizard driven installation.

26. Provision for primary and backup storage settings for individual camera feeds.

27. The VMS shall have ability to configure multiple steams with different quality parameters e.g. Codec (H.264, MPEG, JEPG) , resolution, frame & bit rate etc.

28. Support for full duplex audio

29.

The VMS shall have ability to create and assign pre-configured views/layouts for monitoring including features like:

Custom salvos

Linking dynamic WebPages, images, maps a view,

Sharing a view between users,

Special views for widescreen monitors,

Updating a view only on motion detection,

Rotating live video from a pool of cameras,

Assigning different quality attributes on-the-fly, based on operator’s actions. E.g. different quality settings for selected and non-selected video feeds/tiles/panes.

Granting or revoking permission to use the view etc.

30. Setup Virtual matrix/ video wall with customizable rules & priorities.

31. Basic recording options [Full, Scheduled recoding , Motion detection recording , external/internal hardware or software events / trigger based recording]

32. Advanced recordings options [Video only, Audio only, Video plus Audio, Retention rules, Archive/back-up rules, storage limits etc]

33. The VMS shall have ability to configure, store and track both pre- and post event recordings. The pre-post event time should be configurable.

34. PTZ configuration including presets, patterns, patrolling, masking, priority and permissions.

35. The VMS shall have ability to support operations from Web client, Windows client, and Mobile devices etc.

Page 30: Request for Proposals For - Gujarat State PortalRev)22082013.pdfRequest for Proposals For Appointment of Agency for Design, Site Preparation, Supply, Installation and Maintenance of

CSITMS Gujarat Project Confidential

30

36. Popup display on the screen in case of any event/alarm/threshold etc

37. Multiple monitor support: The system should allow connecting multiple monitors on single client workstation (loaded with suitable graphics card) and display different contents on each of the connected monitor.

38.

All panes / tiles should indicate mode (live or recoded), source (camera name/location) and date/time and applied quality information (FPS, CODEC). The font color shall be changed automatically in sync with the video/image to have a clear text reading at any point of time. A matrix view should support minimum 2x2, 3x3, 4x4…9x9 formats and any number of multiple screen divisions.

39.

PTZ controls: When PTZ is deployed and enabled, system should offer a separate control panel for PTZ operations. The control panel should include list of presets, patterns, tours, eight directional & home positions and zoom-in & zoom-out buttons. A dedicated joystick can also be used for PTZ operations.

40.

PC keyboard shortcut keys: Along with menu-driven interface, a VMS should also support custom shortcut keys to helps operators quickly switch between different modules/screens, change views or panes/tiles and to carry out playback functions.

41. Snapshots: System should allow creating a still image from live or recorded feed and storing it into a workstation.

42.

E-maps: The VMS shall have ability to underscore installed devices on entire facility using e-maps. It should also allow users to quickly search and jump to the right device/camera to carry out interactive functions e.g view the actual camera video, initiate and cancel alarms, etc

43. The VMS shall have ability to boost video quality manually (by operators) or automatically as configured on event trigger or as scheduled.

44. Instant replay facility with configurable replay-duration.

45. The VMS shall have ability to bookmark / add-to-favorites in both live and playback modes. Bookmarks should be user specific and managed (create, share with other users, search, remove, add comment) by the owner.

46. Digital zoom to enlarge portion of an image to provide superior zooming capability.

47. The VMS shall have ability to Start/Stop Recording on demand (manually)

48.

Option to view surrounding cameras: The system should enable operators to select master camera feed and based on group/subgroup details, its surrounding cameras should be automatically displayed on separate panes. These panes/tiles should be dynamically generated so that operator does not

Page 31: Request for Proposals For - Gujarat State PortalRev)22082013.pdfRequest for Proposals For Appointment of Agency for Design, Site Preparation, Supply, Installation and Maintenance of

CSITMS Gujarat Project Confidential

31

need to manually pull the feeds from desired cameras.

49.

Evidence export feature: The system should allow users to export audio/video evidences in open format for internal investigation or to share authentic proof to public authorities and outside agencies. Alternatively the bidder may provide the required player/software to run the exported video file if the VMS not support to export in avi or other standard format. The system should offer options to enable watermarking camera name & timestamp and also encrypt or apply password protection to the exported clips.

50.

The VMS shall have ability to quickly search and retrieve recordings: Search methods should include search by camera(s), group, date/time, alarm/event / bookmark list, smart (motion) search by creating motion index or by generating thumbnail summary of a video archive to locate specific event. The search result should provide an intuitive timeline browser that represents the overall length of the recording. It should underscore recoded event (motion based, scheduled, event based or normal) and allow users to quickly jump back and forth to a location in selected recording. Smart (motion) Search: The feature should enable users to select area of interest on any given view of camera recording, and search for motion incidents within that area

51. The VMS should have onscreen process guidance/help menu & instruction

52.

The system should offer following playback controls

Play/Pause

Lock speed

Forward playback (1x, 2x, 4x, 10x, 20x, 40x,…

Reverse playback (-1x, -2x, -4x, -10x, -20x,-40x, …..

Slow forward playback (frame by frame, 1/8x, 1/4x,1/3x, 1/2x, 1x)

Slow reverse playback

53. Video Lock: The system should allow users to lock the relevant portion of video recording related to any event to avoid the deletion of the important incidence from the system before its retained/backed-up.

54. Evidence Printing: Option to create and print a small surveillance report that includes image(s) and comments about recorded incident.

55. The system should enable users to send/transfer a view to preconfigured displays.

56. The system should offer options to set Hue, Saturation, Brightness, Contrast, Sharpness etc.

57.

The system should have in-built, configurable, basic motion detection analytic engine that efficiently

Detects motion

Virtual line

Auto tracking

Page 32: Request for Proposals For - Gujarat State PortalRev)22082013.pdfRequest for Proposals For Appointment of Agency for Design, Site Preparation, Supply, Installation and Maintenance of

CSITMS Gujarat Project Confidential

32

58.

The system should have in-built event/alarm management module that allows generating, distributing, storing, tracking and reporting of incidents and events as they occur. The module should have The VMS shall have ability to

Define and configure events that can be triggered by motion detection analytics, video loss, audio detection, integrated third party software tools (ANPR, RLVD), active tampering, temperature, connected external devices or by manually activating the same.

Configure automatic/programmed responses based on priority and escalation level for specific event(s).

Send email and SMS notifications to respective users.

Search and view list of triggered events based on source, priority, event type, date/time, keyword etc

Acknowledge events – Change status, key-in more information

Escalate event records to the next level of users or share event records with other users.

Allow manual respond to triggered events including activating external hardware and transmitting I/O commands.

Consolidated e-reports generation with archive video, images, text and other file attachments.

59.

The system should provide interactive reporting interface with standard and user-defined custom reports and filtering options to:

Monitor real-time and history of overall operational health of a surveillance system or individual components (recordings, cameras, servers, storages, CPU, memory, bandwidth etc).

Review currently logged in users and functions being performed.

Retrieve audit trails - user activities, errors and system logs.

View list of hardware units and selected configuration options.

List down configured users and corresponding roles & permissions.

View details of bookmarks, event/alarm history and exported evidences

60.

The system should have Inbuilt diagnostic utility that constantly monitors several different functions of deployed hardware and software modules and attempts to correct the problem in case of deviations from the established baselines occurs.

61. The facility should be there to extract & save the video footages / images on CD, DVD, USB, External Storage etc.

Page 33: Request for Proposals For - Gujarat State PortalRev)22082013.pdfRequest for Proposals For Appointment of Agency for Design, Site Preparation, Supply, Installation and Maintenance of

CSITMS Gujarat Project Confidential

33

6.0 Video Analytics

6.1 Automatic Number Plate Recognition (ANPR)

System should work as local ANPR system as well as Local Surveillance system with remote connectivity and data base management

The system should be a full ANPR system that processes, stores and makes available data collected to the control Room

The system should be able to work as surveillance record video, transmit video

The system should easy to be controlled by a operator in the Control Room

It should generate an alert in case the number plate of passing vehicle is similar to one which is already in the enrolled list as blacklisted, stolen, unregistered vehicle & should be able to generate the alarm simultaneously.

The system should send transit data and images to central system both in real-time (if cellular network available) or offline

The system should be a complete video-surveillance system that record continuously video acquired by the camera and stores onto the automotive hard disk of the rugged onboard processor

It should be the minimum two components

1. A Network Fixed Camera

2. A Processor

System Specification

ANPR System

Very easy user interface.

It acquires continuously images and automatically detects number plates by the use of ANPR Software at local Processor & only sends alerts & processed data to the City Command & Control Centre to save Bandwidth.

Hi-resolution 2MP camera for ANPR and and 3MP Camera for context image and video-surveillance.

IR will be required with ANPR camera but not required with

Page 34: Request for Proposals For - Gujarat State PortalRev)22082013.pdfRequest for Proposals For Appointment of Agency for Design, Site Preparation, Supply, Installation and Maintenance of

CSITMS Gujarat Project Confidential

34

context camera.

It should works with both color and b/w pictures

It should works with both back or front side number plates

It should compares plates in real time with the suspected list (or more than one list) stored in the vehicle. In case the plate belongs to a suspected vehicles list it should does the following actions:

Send images to a control room through network.

Show images and plate at the control room to the operator on the screen with and an eventual action to perform (e.g. “stop that vehicle”, “call this number”, etc.)

Connectivity

Connectivity of the cameras From the field location to the control room including network recording & video streams from all the cameras on 24 x 7 basis with 99.5% up time. It should keep updated the lists automatically by RTO DATA BASE .

When the system finds a plate in the database, it should transmit an alarm to the data center. It sends the strings of the plate, the image acquired.

Performance:

• At 0km/h : average percentage of correct plate read compared to every standard plate readable by a passenger onboard – 40%

• At 30km/h : average percentage of correct plate read compared to every standard plate readable by a passenger onboard – 40%

• At 60 km/h : average percentage of correct plate read compared to every standard plate readable by a passenger onboard - 35%

Central System feature:

Transits storage and visualization

Searching transit images using many criteria, such as:

- Date / time

- Number plate

Searching of alarm detected

Managing and updates of database

Video Surveillance Feature:

The system should be used also as a ‘video-surveillance system’

The system stores images continuously or under the control of the operator,

Specification for 2MP fixed camera with for ANPR

Infrared Illuminator Integrated

Image sensor 1 / 3” CCD/CMOS Progressive Scan (2 MP)

Electronic Shutter

1 to 1 / 10,000 s

Min illumination/

1 lux

Page 35: Request for Proposals For - Gujarat State PortalRev)22082013.pdfRequest for Proposals For Appointment of Agency for Design, Site Preparation, Supply, Installation and Maintenance of

CSITMS Gujarat Project Confidential

35

light sensitivity (Color)

Min illumination/ light sensitivity (B/W)

0.25 lux

Wide Dynamic Range

Required

Backlight Compensation

ON/OFF

FOCUS Automatic / Manual

White Balance Automatic / Manual

Frame Rate 25 FPS for 1920 X 1080

Video

Day and Night functionality

Automatic, Color, Mono

Max video resolution

3 MP (2048 X 1536)

Video Streams Individually configurable 02 video streams (H.264, MJPEG, JPEG)

Intelligent Video

Motion detection, tamper detection

Compression

H.264, MJPEG, MPEG-4

Required

Network & Interface

Interface RJ-45 for 10/100 base-T Ethernet

I/O Port 01 IN, 01 OUT

Upgrade Through web browser , online, firmware upgrade

Network Protocols support

Compatible with TCP/IP, HTTP, ICMP, PPPoE, DDNS, DHCP, UDP, DNS, SMTP, RTP, RTSP, SNMP protocols

Compliance ONVIF

Application programming interface

Open API preferable

Security

Password Required

Page 36: Request for Proposals For - Gujarat State PortalRev)22082013.pdfRequest for Proposals For Appointment of Agency for Design, Site Preparation, Supply, Installation and Maintenance of

CSITMS Gujarat Project Confidential

36

Protection

HTTPS encryption

Required

IEEE 802.1X Required

General

Operational temperature °C

-0 to 50 °C

Housing IP66 rated outdoor housing

Specification for 3MP camera with IR for context view

Image sensor 1 / 3” CCD/CMOS Progressive Scan (3 MP)

Electronic Shutter

1 to 1 / 10,000 s

Min illumination/ light sensitivity (Color)

1 lux

Min illumination/ light sensitivity (B/W)

0.25 lux

Wide Dynamic Range

Required

Backlight Compensation

ON/OFF

FOCUS Automatic / Manual

White Balance Automatic / Manual

Frame Rate 12 FPS for 2048 X 1536

IR Inbuilt / external with 15 Meters range

Wavelength 850 nm

Housing IP 66 outdoor

Video

Day and Night functionality

Automatic, Color, Mono

Max video resolution

3 MP (2048 X 1536)

Video Streams Individually configurable 02 video streams (H.264, MJPEG, JPEG)

Intelligent Video

Motion detection, tamper detection

Compression

Page 37: Request for Proposals For - Gujarat State PortalRev)22082013.pdfRequest for Proposals For Appointment of Agency for Design, Site Preparation, Supply, Installation and Maintenance of

CSITMS Gujarat Project Confidential

37

H.264, MJPEG, MPEG-4

Required

Network & Interface

Interface RJ-45 for 10/100 base-T Ethernet

I/O Port 01 IN, 01 OUT

Upgrade Through web browser , online, firmware upgrade

Network Protocols support

Compatible with TCP/IP, HTTP, ICMP, PPPoE, DDNS, DHCP, UDP, DNS, SMTP, RTP, RTSP, SNMP protocols

Compliance ONVIF

Application programming interface

Open API preferable

Security

Password Protection

Required

HTTPS encryption

Required

IEEE 802.1X Required

General

Operational temperature °C

-0 to 50 °C

Housing IP66 rated outdoor housing

Specification of the Processor

Chipset ICH-8M

CPU Intel® Atom™ D510 Dual Core 1.6

Memory DDR2 667/800 one 200-pin SO-DIMM 2GB

IP Rating: IP66 compliant

Hard Disk Drive

1 x 160G 2.5” SATA II HDD

LAN port 3 x 10/100 Ethernet

Power 8V ~ 60V DC thru 3-pin connector (ignition, power & ground)

Other Features Integrated GPS

Minimum 300,000 transit to be stored

Challaning system

Page 38: Request for Proposals For - Gujarat State PortalRev)22082013.pdfRequest for Proposals For Appointment of Agency for Design, Site Preparation, Supply, Installation and Maintenance of

CSITMS Gujarat Project Confidential

38

Should be integrated with automatic challan system

Complete statistic generation and payment updates

Integrated with RTO data base / HD IITS

Integrated with Crime Branch data base

One platform sharing with Enforcement system

Challan should contain below information before, during and after violation

a) Notice no

b) Location name

c) Offense date

d) Offense time

e) Lane

f) Registration number

g) Violation

h) Light lapse time

i) Penalty amount

j) Due date

k) License base data

Field required in traffic memo application with data type and length

Field Details for New Memo Application In Traffic Module Data type and Length of field

Sr. No. Heading Field Name Type Length

1

Group/Point

Group varchar 20

2 Point varchar 20

3 Memo Type varchar 100

4 Date of Issue datetime NA

5 Memo Number bigint 20

6 Is Wasted char 1

7 License Number varchar 20

8 Vehicle Number varchar 20

Page 39: Request for Proposals For - Gujarat State PortalRev)22082013.pdfRequest for Proposals For Appointment of Agency for Design, Site Preparation, Supply, Installation and Maintenance of

CSITMS Gujarat Project Confidential

39

9

Violation Search

Violation Type varchar 50

10 Act Id varchar 10

11 Act Description varchar 500

12 Section varchar 45

13 Section Description varchar 2000

14 Badge Number varchar 50

15 Type of Vehicle varchar 100

16 Name of Violator (First Name) varchar 50

17 Name of Violator (Middle Name) varchar 50

18 Name of Violator (Last Name) varchar 50

19 Biometric Attachment

File Description varchar 100

20 Attach File LONGBLOB NA

21

Address of Violator

Country varchar 50

22 State varchar 50

23 House Name/No. varchar 150

24 Society/Building Name/Office Name varchar 150

25 Street varchar 150

26 Area varchar 150

27 City varchar 50

28 Other Details(if any) varchar 150

29 Important Landmark(if any) bigint 20

30 Pin code varchar 150

6.2 Red Light Violation Detection (RLVD)

System should be fair system: All evidence before and after infraction

Should be Integrated with automatic challan system with multiple images

Multi user support

User level authentication

Easy to use Graphical Interface

Page 40: Request for Proposals For - Gujarat State PortalRev)22082013.pdfRequest for Proposals For Appointment of Agency for Design, Site Preparation, Supply, Installation and Maintenance of

CSITMS Gujarat Project Confidential

40

System should be totally digital system

Should function upto 100 KMPH vehicle speed

It should automatically recognize number plate of infracted vehicle

It should use the same image for the reading of number plate

It should stored pre and post image of infracted vehicle

It should work on traffic light color

It should not integrated with traffic light

It should store context image of the infracted vehicle as well as close image of infracted vehicle

It should store color image for both day and night for context image

It should store color image for daylight and black & White image for Night light

System should be able to work in 0 lux with the help IR Illuminator

It should use a magnetic probe / inductive loop / virtual line Concept to trigger the camera when traffic light indicate Red Signal

The magnetic probe/inductive loop should be maintenance free.

System should be able to integrate with RTO database

Each frame should be stamped with date time and infarction place

The context image should show the color of traffic light

Software should be able to store all the data temporally on local server after that

Page 41: Request for Proposals For - Gujarat State PortalRev)22082013.pdfRequest for Proposals For Appointment of Agency for Design, Site Preparation, Supply, Installation and Maintenance of

CSITMS Gujarat Project Confidential

41

centralized storage

It Should Produced, Store and transmit a sequence of at least 10 image relatives to any violation detected, or a movie in standard format like avi, mp4, mov, vfw etc

It should produces, stores and transmits images related to the passage of vehicle with the red light switched on, and images previous and following: the system produces a complete documentation about approaching and leaving intersection by Vehicle in infraction

It should detects red light switching on only by image analysis and without any hardware link with red light control boards

It should detects transits in violation overcrossing intersection by passive components placed underground (ex magnetic probes) or inductive loops

Each frame produced by system shows the date and the exact time of the infraction, the crossroads where the infraction took place and the span of time passed after the red light turned on. The frame also show the red traffic lights

Each peripheral system transmits violation's images by any type of TCP-IP channel,

For each violation system performs ANPR algorithms to automatic recognize plate of vehicles in infraction

It has at least one camera for panoramic view in which red light switched on is visible and one or more cameras to see plates of vehicles in infraction each for one lane maximum 5 meters with

The system uses IR illuminator for night conditions, and do not use any flashes lights because it can be dangerous for vehicles circulation

All peripheral violation detectors involving a specified area are centralized in a single server

Page 42: Request for Proposals For - Gujarat State PortalRev)22082013.pdfRequest for Proposals For Appointment of Agency for Design, Site Preparation, Supply, Installation and Maintenance of

CSITMS Gujarat Project Confidential

42

Imaging Device

Sensor 1/3” CMOS/CCD Sensor

Day Night Camera

Lens: Varifocal (Lens size based on the location)

Day and Night: Automatically removable infrared-cut filter

Shutter Time: 1/10000 s to 1/6 s

Video Compression: MJPEG, H.264

Resolutions: 2048x1536 (3 MP) to 320x240

Field of view for License Plate recognition:

up to 25 meters (installing external IR in front of camera)

Video Streaming: Multiple simultaneous individually configurable streams in H.264 and MJPEG Controllable frame rate and bandwidth

Image Settings: Compression, color, brightness, sharpness, contrast, white balance, exposure control, exposure zones, backlight compensation, fine tuning of behavior at low light

Supported Network Protocols:

HTTP, FTP, RTSP

Inside Camera Power:

PoE 802.3af, 24VAC

Housing Power Pl. specify

Housing Construction:

Aluminum

Environmental IP66

IR Illuminator

Spectral emission 850nm

Beam angle 10˚

Temperature Range -50˚ C (-58˚ F) to 50˚ C (122˚ F)

Voltage Input 12 – 40 VDC or 24 VAC (± 30 %)

Power consumption 45 W

Environmental IP 67

Technical Specification for Processor hardware (outdoor- Poll mount) IP66

Chipset ICH-8M

CPU Intel® Atom™ D510 Dual Core 1.6 or better

Page 43: Request for Proposals For - Gujarat State PortalRev)22082013.pdfRequest for Proposals For Appointment of Agency for Design, Site Preparation, Supply, Installation and Maintenance of

CSITMS Gujarat Project Confidential

43

Memory DDR2 667/800 one 200-pin SO-DIMM 2GB

Construction Aluminum enclosure with fan less design

Dimensions 320mm (L) x 176mm (W) x 50mm (H)

IP Rating: IP66 compliant

Hard Disk Drive 1 x 160G 2.5” SATA II HDD

LAN port 3 x 10/100 Ethernet

Power 8V ~ 60V DC thru 3-pin connector (ignition, power & ground)

More than 300,000 transit to be stored

6.3 Manual Challan

General

The operator should be able to pause the video feed, copy & paste the snapshot on manual challan from recorded video feeds as per the requirement. The vendor has to ensure the compatibility between the manual challan software the VMS from where the photo/videos to be copied.

Manual challan form should appear on the screen alongside the video display section.

The operator should be able to fill the vehicle registration / license plate number in the manual challan form & the rest of the datas should be filled automatically. In case if required the system should allow operator to fill all the relevant datas.

The manual challan system should be capable of integration with the RTO database to fetch the vehicle ownership details from the same with respect to the vehicle registration / license plate number.

In case the data base does not contain the ownership details with respect to vehicle registration / license plate number operator should be able to fill in all the desired details manually.

All manual entries must have an audit trail and should be controlled by necessary authorizations.

Page 44: Request for Proposals For - Gujarat State PortalRev)22082013.pdfRequest for Proposals For Appointment of Agency for Design, Site Preparation, Supply, Installation and Maintenance of

CSITMS Gujarat Project Confidential

44

The system should be able to extract the desired picture frame from the video feed being displayed.

This picture frame should be saved in the system along with the manual challan under a unique system generated ID with time & date.

Operating System Microsoft Windows XP / Vista / Seven (32 and 64 bit) / Linux

Software environment Microsoft .NET framework v. 2.0 and above

Database Work with major DBMS software

Scalability

The system should be scalable enough to expand in terms of storage, no of users, format supported, clients, number of challan etc. Should have scalability to be executed on various hardware from a single pc to a high availability cluster with hundreds of connected clients

Statistics Can generate statistics of number of challan aggregated into a specified period.

Special statistics can be made on customer request

Challan feature

Highly customizable.

Should be generated in preferred customized format.

should have facility to store templates of the challan types

High resolution images

Print markers

Charts

It should be possible to insert all data like date, time, street, license plate, owner name, address, money amount etc.

The evidence photo on challan shall have actual time , date of the event occurred

The system should allow user to insert any images like Police logo or other objects like barcode (mono or bidirectional), print markers, charts and many others.

The system should be capable of extracting and viewing recorded camera feed from the storage.

eChallan export formats PDF, JPEG and other standard images formats.

VMS Compatibility The system should be capable enough to be integrated with reputed ONVIF compliant software. If any third party / bridging software required then the same shall be borne by the bidder.

Page 45: Request for Proposals For - Gujarat State PortalRev)22082013.pdfRequest for Proposals For Appointment of Agency for Design, Site Preparation, Supply, Installation and Maintenance of

CSITMS Gujarat Project Confidential

45

7.0 Data Center

7.1 Air conditioners

The Air conditioner shall be High sensible cooling capacity and high SHR (i.e. the

sensible to total cooling capacity ratio). Low running costs, achieved by means of

sophisticated design and co-design methods, combined with an accurate selection of

the components. The whole range of units shall be "environment friendly" because it

uses materials that can be recycled, particularly for the plastics and the thermal

insulation.

1. Cabinet

The cabinet should be constructed using double folded panels with hi-tech riveted

construction; from best quality sheet steel suitably treated for weather protection,

corrosion and should be powder coated.

2. Refrigerant Circuit

The refrigerant system shall be of the direct expansion type and incorporate one or

two hermetic scroll compressors complete with crankcase heaters. A hot gas bypass

and solenoid valve shall be used on single compressor models to provide two steps of

cooling.

3. Compressor

The compressor shall be of the high efficiency compliant scroll design, with an E.E.R. of not less than 11.1 BTUH/watt at ARI rating conditions. Each compressor shall have rotolock valve for service purpose & have inbuilt overloads, HP & LP controllers and mounted on vibration isolators.

Pressure gauge ports should be provided in each compressor

Expansion valve should be Thermostatic type for higher reliability of Units.

Time delay circuit should be provided to each compressor for restart in case of supply interruption.

Page 46: Request for Proposals For - Gujarat State PortalRev)22082013.pdfRequest for Proposals For Appointment of Agency for Design, Site Preparation, Supply, Installation and Maintenance of

CSITMS Gujarat Project Confidential

46

4. Blower Section

Airflow should be constant under all operating modes, including dehumidification, so

that uniform air distribution is maintained.

Forward curved centrifugal fans should be used. The fans should be dynamically

balanced and each fan should have a separate motor and drive.

Fan Motor Assembly:

Fan should be driven by a weatherproof electric motor suitable for operation on

415+ 10% variations 3 phase, 50 Hz Ac supply. The motor housing should be of IP22

degree of protection and class F insulation.

The fan should be belt driven having a maximum speed of 1400 rpm. Each fan should

have its own self-adjusting, permanently aligned belt drive.

5. Evaporative Coil

The Evaporator coil should be V/A shaped constructed, for higher efficiency, of rifled

bore / inner grooved copper tubes of gauge 27swg and louvered aluminium fins

(11/14 fins per inch)

The frame and drip tray should be fabricated from heavy gauge aluminium . The drip

tray must be doubling angled for condensate flow and easily removable for cleaning.

6. Dehumidification feature

It should be achieved by reducing effective coil area by solenoid valve arrangement

and controlled by micro processor based control system. Constant air flow air flow

rate is to be maintained even during dehumidification.

7. Air Cooled Condenser

Each condenser unit should incorporate the following:

A heat rejection coil block should be constructed from copper tubes of not less

Page 47: Request for Proposals For - Gujarat State PortalRev)22082013.pdfRequest for Proposals For Appointment of Agency for Design, Site Preparation, Supply, Installation and Maintenance of

CSITMS Gujarat Project Confidential

47

than27 gauge copper tubes expanded on to straight aluminum fins (Approx 13

fins/inches)

The fan should be selected for quiet operation. The fan should be directly driven

by a motor of speed not exceeding 1400 RPM and constructed from CRCA sheet

and powder coated. When compressor stops condenser fan should also stop.

The motor housing should be of IP54 degree of protection and class F

insulation. The condenser should be suitable for horizontal / Vertical

mounting type

The entire assembly should be supported by a corrosion treated frame having

four legs

8. Humidifier

Humidification should be provided by boiling water in a high temperature

polypropylene steam generator. The steam should be distributed evenly into the

bypass air-steam of the Indoor-cooling unit. The humidifier should be capable of

providing 6 kg of steam per hour. The humidifier should have an efficiency of not less

than 1.3 kg/kW and be fitted with an auto flush cycle activated on demand from the

unit’s control system. The humidifier should be fully serviceable with replaceable

electrodes. Wastewater should be flushed from the humidifier by the initiation of the

water supply solenoid water valve via a U-pipe system. The humidifier shall be type

test certified for direct connection to portable water supplies.

9. Electric Heating:

The electric heating elements should operate at a level not exceeding 60 kw/sq.m .

The low watt density elements should be of finned tubular nickel-plated steel

construction. The heating circuit should include dual safety protection through loss of

air and high temperature controls.

10. Electric System

The Electrical power system should confirm to relevant I.S. standard. A main

isolator (MCB) should be provided on the unit sized to meet the system total

power requirement.

Page 48: Request for Proposals For - Gujarat State PortalRev)22082013.pdfRequest for Proposals For Appointment of Agency for Design, Site Preparation, Supply, Installation and Maintenance of

CSITMS Gujarat Project Confidential

48

Within the panel individual power loads should be distributed equally across the

three phases through a bus bar.

Low voltage and high voltage protection for micro-processor control

All individual wires should be of copper and colour coded or should be numbered

at their point of termination to facilitate servicing.

Low voltage control wiring and power wiring should be segregated from

each other. The following should be incorporated

Motor Protection circuit breakers (MPCB) of suitable rating should be provided

for each sub-circuit.

Single-phase preventers in the main incoming, of Minilec make model VMRD2.

Auto-Off-Manual switch is to be provided.

11. Electric Power Switchboard

It should consist of Switchgear and main isolator switch mounted on DIN rails for

serviceability. Each circuit should be protected by separate circuit breakers and all

live parts protected against accidental contact.

12. Filter

Microvee Filter of 100 mm depth should be fitted in the unit with 95% efficiency

down to 5 microns of dry media disposable type (HDPE – EU5).

13. Service Access

No side access should be required for servicing and maintenance. All servicing should

be possible from the front of the unit only.

14. Microprocessor Controller

Page 49: Request for Proposals For - Gujarat State PortalRev)22082013.pdfRequest for Proposals For Appointment of Agency for Design, Site Preparation, Supply, Installation and Maintenance of

CSITMS Gujarat Project Confidential

49

Each Air conditioner should have single microprocessor with following controls:

Control Type:

The controls shall be a microprocessor based, PID based programmable logic

controller. The controls shall have separate indication of operating modes (cooling,

heating, humidifying and dehumidifying), alarm conditions (temperature high, loss of

sensor, compressor HP & LP, wet floor, no air flow and low humidifier water). The

display and indication shall be visible on the front without removing any external

panels. Local and remote alarms will be triggered if an alarm condition is reached.

Alarms:

The alarm should operate with the audible signal.

Following alarms should be available:

High & Low Temperature / Loss of Sensor

High & Low Humidity

Compressor High / Low Pressure

Water under floor

Loss of Air flow

Low Humidifier Water.

Compressor Short Cycle

Condenser water flow fail

Service Intervals

Low Battery

Brownout

Spare Alarms for Customization

Proportional Integral and Derivative (PID) & Dew point control strategies should be

employed.

Diagnostics

An onboard brownout detection circuit should protect the controller from

abnormally low mains voltages and initiate a staged restart of the unit’s components

when the main returns to normal levels.

Page 50: Request for Proposals For - Gujarat State PortalRev)22082013.pdfRequest for Proposals For Appointment of Agency for Design, Site Preparation, Supply, Installation and Maintenance of

CSITMS Gujarat Project Confidential

50

The control should have an auto-restart feature which will return the unit to normal

operation resumption of mains power.

Display

In normal operating mode the screen should display unit number, temperature and

relative humidity set points and actual, graphs, time, date and operating status. It

should be able to record a real time 48 hour data log of temperature and humidity

updated every minute.

7.2 UPS

Technical Specifications of True On-line UPS:

General

The specification defines the electrical and mechanical characteristics and

requirements for a continuous duty, highly reliable, solid state type true on-line fully

microprocessor controlled double conversion PWM IGBT based Inverter and 6/12

Pulse SCR Rectifier based Uninterruptible Power Supply systems. The UPS shall

provide high quality AC power for sensitive electronic equipment loads. It shall also

supply clean power automatically without any break in supply in the absence of raw

power. Under no conditions will be protected system get direct supply from the raw

mains unless there is fault in the protected system.

All the manufacturers have to ensure that their product confirm to be IEC 146 part IV

standards & specifications set in this document. Non compliance will result in the

disapproval of the product. The UPS shall be connected in PRS mode.

Standards

The UPS and all associated equipment and components shall be manufactured

in accordance with the following applicable standards:

• IEC 62040-1-1: General and Safety requirements.

• EN 50091-2: EMC Requirements

Page 51: Request for Proposals For - Gujarat State PortalRev)22082013.pdfRequest for Proposals For Appointment of Agency for Design, Site Preparation, Supply, Installation and Maintenance of

CSITMS Gujarat Project Confidential

51

• IEC 62040-2: Uninterruptible Power System (UPS) part 2: EMC requirements

• IEC 62040-3: Performance requirements and Test Method

• EN 60950: Information Technology equipment

• EN 60529: Degrees of protection provided by enclosures (IP Code)

The Quality System for the engineering and manufacturing facility shall be

certificated to conform to Quality System Standard ISO 9001 for the design and

manufacture of power protection systems for computers and other sensitive

electronics.

System Description

a) Design Requirements – UPS Module

i) Input Voltage rating: 380/400/415 volts three-phase, Three wire

for rectifier and 4 wire for bypass.

ii) Input Voltage range: +10%, -15%

iii) Input Frequency: 50Hz +/-5%

iv) Output Voltage regulation (at default parameter settlings):

• +/-1% steady state for a static 100% balanced load. • +/- 2% steady state for a static 100% unbalanced load. • +/-5% for a 0 to 100% load step.

v) Output Frequency: 50Hz +/- 0.1 Hz free running (battery operation).

Under synchronized condition with bypass UPS output frequency shall be between 48 to 52 Hz.

vi) Crest Factor: 3 : 1

vii) Voltage Transient Response:

• +/- 3% for a 50% load step. • +/- 5% for a 100% load step.

viii) Voltage Recovery to +/- 1 % ,Transient Recovery Time: <=20 milli seconds.

ix) Phase Displacement:

• 120 degrees +/-1 degree for balanced load • 120 degrees +/- 1 degree for 50% unbalanced load

Page 52: Request for Proposals For - Gujarat State PortalRev)22082013.pdfRequest for Proposals For Appointment of Agency for Design, Site Preparation, Supply, Installation and Maintenance of

CSITMS Gujarat Project Confidential

52

• 120 degrees +/- 1 degree for 100% unbalanced load

x) Overload Capability: • 110% for 60 minutes • 125% for 10 minute • 150% for 60 seconds • 200% single phase for 30 seconds

xi) Short Circuit Withstand: The UPS shall withstand a bolted fault short

circuit on the output without damager to the UPS module.

xii) AC to AC efficiency: > 90% with filters from 50% load to 100% non

linear load, at nominal input voltage with batteries fully charged.

xiii) Acoustical Noise : <65 dB(A) of noise, typical, measured at 1 meter from

the operator surface.

xiv) Inverter short circuit Current limit - 155% full load current

for instantaneous.

b) Mode of Operation

The UPS shall be designed to operate as Double conversion True ON LINE VFI as per IEC 62040-3

i) Normal – The critical AC load is continuously supplied by the UPS

Inverter. The rectifier/ Charger derives power from AC Input source and supplies DC power to the Inverter while simultaneously charging power reserve battery.

ii) Emergency – Upon failure of AC Input power, the critical AC load is

supplied by the inverter which without any switching obtains power from the battery.

There shall be no interruption in power to the critical load upon failure or restoration of the AC input source.

iii) Recharge – Upon restoration of AC input power during the emergency

mode of operation, the rectifier/charger shall automatically restart, walk-in and gradually assume the inverter and battery recharge loads.

iv) Bypass – UPS must have for static bypass switch in addition to manually

operated maintenance bypass switch. Manual switch should be

Page 53: Request for Proposals For - Gujarat State PortalRev)22082013.pdfRequest for Proposals For Appointment of Agency for Design, Site Preparation, Supply, Installation and Maintenance of

CSITMS Gujarat Project Confidential

53

incorporated into UPS cabinet that will connect the load to AC power source bypassing the rectifier/charger, inverter and static transfer switch.

v) SNMP (Simple Network Management Protocol) - Web enabled adopter

card with smart software for server shutdown shall be provided by UPS vendor.

vi) Dual Bus system - The two UPS systems should work in Load Bus

Synchronization mode. Both the UPS shall share 50% of the total load. The malfunction of one of the modules shall cause that module to be disconnected automatically from the load and the healthy module shall continue to carry the total load. Upon repair of the module, it shall be reconnected to the critical load to resume dual supply operation. Any module shall also be capable of being taken off the load manually for maintenance without disturbing the load bus.

vii) Maintenance Free Battery Requirements - Battery bank connected to

each 40 KVA or adequate capacity UPS shall be designed to provide 30

minutes back-up at full load. The UPS module should be automatically

disconnected when the battery reaches to the minimum discharge voltage level or when signaled by other control functions. During normal operation batteries shall be continuously float charged & the charging current is electronically controlled for the limiting purpose.

c) Performance Requirements

The UPS is VFI classified (according to IEC 62040-3) producing an output waveform that is independent of both the input supply frequency and voltage.

i) UPS AC Input

Voltage Range: ±15% (rectifier is operational until -25% is

exceeded) Frequency Range: ±5%

In-rush Current Limiting: 20% to 100% of full rated current over 10 seconds. Power Factor: For 6 pulse modules, minimum of 0.8 lagging at full load with nominal input voltage (can be increased to 0.95 lagging with optional input filter.) For 12 pulse modules with input filter permits operation with the filter connected down to 10% rated load without the

Page 54: Request for Proposals For - Gujarat State PortalRev)22082013.pdfRequest for Proposals For Appointment of Agency for Design, Site Preparation, Supply, Installation and Maintenance of

CSITMS Gujarat Project Confidential

54

input power factor going leading.

2-Step Input Current Limit: Maximum of 125% normal full load input current. (100% for generator operation.)

Temperature Compensated Charging: Above 25ºC the battery charge voltage shall reduce by 2mV per cell per ºC in order to optimize on the battery lifetime.

Current Distortion: Less than 30% THD at full load input current for a 6 pulse modules; the optional input filter shall reduce this input current distortion to less than 9% THD at full load. Less than 8.5% THD at full load current for a 12 pulse modules; the optional input filter shall reduce this input current distortion to less than 4% THD at full load.

ii) UPS Output

Load Rating: 100% continuous load rating at 40ºC for any combination of linear and non-linear loads.

Voltage Regulation: 1% steady state for balanced load, 2% for 100% unbalanced load.

Frequency Regulation: ± 1Hz synchronized with bypass source, ± 0.01Hz free running or on battery operation.

Frequency Slew Rate: 0.1Hz per second.

Efficiency: Defined as output kW / input kW at a load power factor of 0.8 lagging:

Up to 93.5% efficient at full rated load for 6 pulse modules when operating as a true on-line configuration.

Up to 92.9% efficient at full rated load for 12 pulse modules when operating as a true on-line configuration.

Phase Imbalance:

120º ±1º el. for balanced loads. 120º ±1º el. for 100% unbalanced loads Voltage Transients: ± 5% for 100% output load step. Transient Recovery Time: To within 1% of steady state output voltage within 20ms

Page 55: Request for Proposals For - Gujarat State PortalRev)22082013.pdfRequest for Proposals For Appointment of Agency for Design, Site Preparation, Supply, Installation and Maintenance of

CSITMS Gujarat Project Confidential

55

7.3 Access control system

a. General

The intent of this document is to specify the minimum criteria for the Design,

Supply, Installation, and Commissioning & Maintenance of Access Control System.

The work under this system shall consist of design, supply, installation, testing,

training & handing over of all materials, equipment’s and appliances and labor

necessary to commission the said system, complete with Door controller,

Proximity card reader, Electromagnetic locks, Magnetic contact and Emergency

release switch. It shall also include lying of cabling, necessary for installation of

the system as indicated in the specification and Bill of Quantities. Any

openings/chasing in the wall/ceiling required for the installation shall be made

good in appropriate manner.

The software for the Fire alarm, Access control and CCTV system shall run on a single platform. The specification for the same is provided along with the fire alarm system and vendor shall comply point-wise on the requirement.

b. Scope

The scope of work shall include the design, supply, installation, commissioning, integrating, guaranteeing and maintenance of an integrated access control system.

c. Operational Requirements

The Access Control System (ACS) as outlined in the tender document shall be used to control the flow of authorized personnel through the secured access area of the facility.

Individual access cards shall be issued to all the employees. The system shall authorize entry only after the card read by the smart card reader is validated with respect to door, time & day of the week. For authorizing an exit, the system shall verify the validity of the card read by the reader and release the door lock

The document shall provide an outline of the various parameters that are specified, as minimum requirements, with respect to various hardware & software components required for the implementation of an integrated security & access control system. This document together with the detailed schedule of quantities for the site forms the basis for the tender issued.

Page 56: Request for Proposals For - Gujarat State PortalRev)22082013.pdfRequest for Proposals For Appointment of Agency for Design, Site Preparation, Supply, Installation and Maintenance of

CSITMS Gujarat Project Confidential

56

d. Access Software Features & Requirements General Description

i. The Access control system software shall be a module in the integrated

software. The Access Control System software shall be capable of integrating multiple functions including Access control, Time and Attendance Management of employees, Alarm Management, Database Partitioning, and external system database sharing of employee personal information (Import Utility).

ii. The system shall be modular in nature, and shall permit expansion of both

capacity and functionality through the addition of control panels, card readers, software modules and sensors.

iii. The system shall incorporate the necessary hardware, software, and firmware

to collect, transmit, and process alarm, tamper and trouble conditions, access requests, and advisories in accordance with the security procedures configured. The system shall control the flow of authorized personnel traffic through the secured areas of a facility.

iv. The user interface at the host computer (server) and at the UWS (user

workstation computers) shall be a mouse driven graphical user interface (GUI) allowing the user to open and work on multiple windows simultaneously.

Abbreviations

The following abbreviations are used in this document:

ASCII American Standard Code for Information Interchange BPS Bits per Second CPU Central Processing Unit ID Identification I/O Input/output ISDN Integrated Standard Digital Network GUI Graphical User Interface LAN Local Area Network UWS User Workstation (computer) ODBC Open Database Connectivity PIN Personal Identification Number PSTN Public Switched Telephone Network TCP/IP Transmission Control Protocol / Internet Protocol WAN Wide Area Network

Page 57: Request for Proposals For - Gujarat State PortalRev)22082013.pdfRequest for Proposals For Appointment of Agency for Design, Site Preparation, Supply, Installation and Maintenance of

CSITMS Gujarat Project Confidential

57

Glossary of Terms

The following terms are defined for the purpose of this specification:

Card Profile - A logical group of doors which may be connected to one controller and

which represent a collection of readers for which a particular cardholder may have

access privileges.

Acknowledge - The action taken by an operator to indicate that he/she is aware of a

specific alarm or tamper state.

Process – The action taken by an operator to indicate that he/she is satisfied that

the alarm has been attended to and can be cleared from the screen.

Alarm - A change of state as sensed by the ACS Software indicating that the ACS

Software has detected a condition, which its sensors were designed to detect.

Badge - The physical card, carried by the Cardholder used to gain access through a

door by presentation to a Card Reader.

Cardholder - A person who is a member of the Cardholder database and may or may

not have been issued a valid badge.

Card Reader - A device usually located at access points, designed to decode the

information contained on or within a badge for the purposes of making an access

decision or for identity verification.

Download - To send computer data from one sub-system to another; for example, to

send a cardholder database from the ACS Software server to a controller for the

purposes of making access decisions without the intervention of the host PC.

Facility Code - A coded number, in addition to the individual card number, stored

within each card key, which uniquely identifies the facility at which the card is valid.

This feature prevents cards from one facility from being used at another facility that

has a similar Security System.

Server - The central computer that serves as the common point controller for the

Page 58: Request for Proposals For - Gujarat State PortalRev)22082013.pdfRequest for Proposals For Appointment of Agency for Design, Site Preparation, Supply, Installation and Maintenance of

CSITMS Gujarat Project Confidential

58

remote user workstation terminals, as an alarm monitoring and control workstation,

as a point of integration for related sub-systems, and as a central data base server.

Line Supervision - The monitoring of an electrical circuit via electrical and software

systems to verify the electrical integrity of the supervised circuit.

Off-line - A condition in which a controller(s) is not in communication. In the off-line

mode, the controller continues to make access decisions and process alarms

according to the information stored at its local database.

User Workstation (UWS) - a personal computer connected to the ACS Software

server computer via local area network connections for the purpose of operating the

system and responding to alarms.

Password - A combination of numbers and/or letters unique to each ACS Software operator.

Reset - A command or feedback signal that indicates that a monitored point has returned to its normal state after having transferred to the alarm or trouble state.

Armed - The normal state of an alarm input point in which it will be monitored for change of state, which would indicate that it has transferred to the alarm state.

Secured Area - A physical location within the facility to which access is controlled by one or more card readers.

Tamper - A condition within the circuitry of a monitored point, which indicates that the electrical integrity of that sensing circuit has been compromised.

Time Zone - A user programmable period made up of days of the week and hours of the day during which events such as valid card grants and Input/output linking events may occur.

e. Software Architecture

i. Server

The ACS Software Server shall be configured to be located at the Central

integrated software. The ACS Software server shall operate on Windows XP/Vista/

Page 59: Request for Proposals For - Gujarat State PortalRev)22082013.pdfRequest for Proposals For Appointment of Agency for Design, Site Preparation, Supply, Installation and Maintenance of

CSITMS Gujarat Project Confidential

59

2008 Server Platforms. The Server shall consist of various managers that are

assigned specific functionalities logically grouped together and shall control all

access to the database.

In some areas, access control should be given after entering the code. In Control room, which person is sitting on which console and other info should have date and time stamp on it so that whoever tempers with evidence shall be caught.

The ACS Software Server shall be designed for unattended execution and should not have any user interface.

ii. User Workstation

The UWS shall be dedicated to act as a card issue terminal/System

Monitoring/Administration Station. The UWS shall be connected to the ACS Software Server over a dedicated Ethernet LAN/Internet. The UWS shall provide

the GUI in the familiar windows point and click environment for easy maneuverability. Various configurable parameters shall be logically grouped and shall be available

in various consoles.

f. System Architecture

i. General

The Access Control System Management System (ACS Software) shall use a Client Server architecture based around a modular PC network, utilizing industry standard operating systems, networks and protocols. The system shall allow the distribution of system functions such as monitoring and control and graphical user interface etc. across the network to allow maximum flexibility and performance. The architecture shall include support native Ethernet LAN / WAN using standard hardware and software to link nodes into a single integrated system. The network protocol used shall be industry standard TCP-IP / UDP

ii. Software features

The software shall have a capacity to accommodate the following based

on licensing A central database on the server able to support up to

unlimited badges

Unlimited number of card profiles.

Page 60: Request for Proposals For - Gujarat State PortalRev)22082013.pdfRequest for Proposals For Appointment of Agency for Design, Site Preparation, Supply, Installation and Maintenance of

CSITMS Gujarat Project Confidential

60

Unlimited number of operators.

Central on-line data storage of historical transactions, expandable as

system resources allow.

255 levels of alarm priority

Multiple badge numbers per cardholder. Each badge can be tracked

separately.

Multiple issue levels per card, only one of which shall be active at any

given time

Fifty user-defined card holder fields. The system shall be capable of

reporting on any or all of the user-defined fields. Each user-defined field

may be defined by the user as alphanumeric, numeric, or Text List.

Support all time zones with 2 on & 2 off periods. And 3 set of times

corresponding to 3 security levels.

Anti-pass back feature support.

Door open time set for each door.

The time in and time out is calculated on the first in and last out basis.

Supports day and overnight shifts.

Overtime calculations.

Detailed data entry fields in employee master.

Employee master maintained for various locations/branches.

Employee code up to 8 digits.

Employee master maintained for old employees on location basis.

Photographs can be stored for each employee.

Manual Entries

Outdoor duty entries

In/Out Personals

Tour entries

Department types, employee types, grades, locations maintained.

Grace time for different grade types.

Backup and restoration facilities for employee master and swipe data.

Reports on employee master and time and attendance.

Login and authority rights to the software can be set for each user.

Leave system set on calendar or financial year or any month of the year.

Pro-rata calculation of leaves.

Leave register maintained for CL, SL, PL and other leaves.

Maternity and marriage leave setup.

Page 61: Request for Proposals For - Gujarat State PortalRev)22082013.pdfRequest for Proposals For Appointment of Agency for Design, Site Preparation, Supply, Installation and Maintenance of

CSITMS Gujarat Project Confidential

61

Carry forward of previous years leave.

Backend Database: ODBC compliant

Data can be stored on a central database server.

Front end: GUI based user-friendly interface based on client server

technology for Windows 2000/XP/2003 Server environment.

Third party interface: ASCII flat files with coma separated values as per

requirement

Architecture: 3 Tier (User, Business & Data services) to ensure scalability

Operators: Unlimited

Configuration: Full set up & programming of all door controller functions

Card Database: To contain Photo image of cardholder along with other

relevant data.

Card profiles: Unlimited with respect to single card or batch of cards. Shall

define valid doors, 3 time zones per card applicable to weekday, off day &

holiday

Archival: Daily automatic archival based on defined time.

Reports: User definable access reports with respect to time, Date, door &

card. Daily Attendance reports based on 1st IN & last OUT. Reports should

also include archived data.

Door Control: Each Door individually or all door simultaneously may be

locked / unlocked or normalised from the PC.

Roll call: The software shall be able to provide the no. of list of card

holders in the premises. It shall also be capable locating an user based on

the last transaction.

iii. Operator Interface Characteristics

ACS Software shall provide a Windows operator interface as standard. No custom programming or scripting shall be necessary to produce the following: Window re-size, dedicated icons and Pull down Menus to perform the following:

Associated Alarm Display Alarm Summary Alarm Acknowledgement Graphic Call-up

Page 62: Request for Proposals For - Gujarat State PortalRev)22082013.pdfRequest for Proposals For Appointment of Agency for Design, Site Preparation, Supply, Installation and Maintenance of

CSITMS Gujarat Project Confidential

62

Card Holder Detail Alarm Banner showing priority System Date Current Operator

iv. Operator Functions

The following functions shall be performed through the operator interface:

Display and control of door control units Acknowledge alarms on a priority basis Initiate printing of reports Archive and retrieve event logs Change own password Monitoring of data communications channels Configure system parameters

v. Operator

Security

Each operator shall be assigned a user profile that defines the following:

Operator Identifier or User Name Unique Password

Workstation Access Password expiry parameters Any actions initiated by the operator shall be logged in the Event database

by operator identifier.

Area Assignment / Area Profile

Each operator shall be assigned a specific area of the building with the appropriate monitoring and control responsibility (no view, view only, alarm acknowledge only or full control). An area shall be defined in this context as a Partition. This in turn may represent a physical space in the building. This can be used to partition the database in such a way as to assign operators control over certain areas and prevent unauthorized access to other areas.

vi. Standard System Displays

The ACS software shall be capable of storing a number of graphic displays (maps). The quantity of such maps shall be limited by available hard disk storage space

Page 63: Request for Proposals For - Gujarat State PortalRev)22082013.pdfRequest for Proposals For Appointment of Agency for Design, Site Preparation, Supply, Installation and Maintenance of

CSITMS Gujarat Project Confidential

63

only. Display maps) are layered i.e. lower level maps associated with the top layer map existing in the system. It should be possible to navigate through the displays (maps) layers by clicking on the sections of a map layer. The following displays shall be included as part of the system:

Alarm

Display

Alarm Count Event display

7.4 Fire detection and suppression

Addressable Fire Detection System

General

a. Description

i. This section of the specification includes the furnishing, installation,

connection and testing of the microprocessor controlled, intelligent

reporting fire alarm equipment required to form a complete, operative,

coordinated system. It shall include, but not be limited to, alarm initiating

devices, alarm notification appliances, Fire Alarm Control Panel (FACP),

auxiliary control devices, annunciators, and wiring.

ii. The fire alarm system shall comply with requirements of NFPA Standard

72 for Protected Premises Signaling Systems except as modified and supplemented by this specification. The system shall be electrically supervised and monitor the integrity of all conductors.

iii. The FACP and peripheral devices shall be manufactured 100% by a

manufacturer (or division thereof).

iv. The system and its components shall be Underwriters Laboratories, Inc.

listed under the appropriate UL testing standard as listed herein for fire alarm applications and the installation shall be in compliance with the UL listing.

b. Scope

i. A new intelligent reporting, microprocessor controlled fire detection

system shall be installed in accordance to the specifications as detailed in the tender document / RFP. AMC fire department’s certificate required.

Page 64: Request for Proposals For - Gujarat State PortalRev)22082013.pdfRequest for Proposals For Appointment of Agency for Design, Site Preparation, Supply, Installation and Maintenance of

CSITMS Gujarat Project Confidential

64

ii. Basic Performance:

Alarm, trouble and supervisory signals from all intelligent reporting devices shall be encoded on NFPA Style 6 (Class A) Signaling Line Circuits (SLC).

Initiation Device Circuits (IDC) shall be wired Class A (NFPA Style D) as part of an addressable device connected by the SLC Circuit.

Notification Appliance Circuits (NAC) shall be wired Class A (NFPA Style Z) as part of an addressable device connected by the SLC Circuit.

On Style 6 or 7 (Class A) configurations a single ground fault or open circuit on the system Signaling Line Circuit shall not cause system malfunction, loss of operating power or the ability to report an alarm.

Alarm signals arriving at the FACP shall not be lost following a primary power failure (or outage) until the alarm signal is processed and recorded.

iii. Basic System Functional Operation

When a fire alarm condition is detected and reported by one of the system initiating devices, the following functions shall immediately occur:

The system alarm LED on the system display shall flash.

A local piezo electric signal in the control panel shall sound.

A backlit LCD display shall indicate all information associated with the fire alarm condition, including the type of alarm point and its location within the protected premises.

Printing and history storage equipment shall log the information associated each new fire alarm control panel condition, along with time and date of occurrence.

All system output programs assigned via control-by-event interlock programming to be activated by the particular point in alarm shall be executed, and the associated system outputs (notification appliances and/or relays) shall be activated.

c. Submittals

Page 65: Request for Proposals For - Gujarat State PortalRev)22082013.pdfRequest for Proposals For Appointment of Agency for Design, Site Preparation, Supply, Installation and Maintenance of

CSITMS Gujarat Project Confidential

65

i. General

Two copies of all submittals shall be submitted to the Owner’s authorised official for review.

All references to manufacturer's model numbers and other pertinent information herein is intended to establish minimum standards of performance, function and quality. Equivalent compatible UL-listed equipment from other manufacturers may be substituted for the specified equipment as long as the minimum standards are met.

For equipment other than that specified, the contractor shall supply proof that such substitute equipment equals or exceeds the features, functions, performance, and quality of the specified equipment.

ii. Shop Drawings

Sufficient information, clearly presented, shall be included to determine compliance with drawings and specifications.

Include manufacturer's name(s), model numbers, ratings, power requirements, equipment layout, device arrangement, complete wiring point-to-point diagrams, and conduit layouts.

iii. Manuals:

Submit simultaneously with the shop drawings, complete operating and maintenance manuals listing the manufacturer's name(s), including technical data sheets.

Wiring diagrams shall indicate internal wiring for each device and the interconnections between the items of equipment.

Provide a clear and concise description of operation that gives, in detail, the information required to properly operate the equipment and system.

iv. Software Modifications

Provide the services of a factory trained and authorized technician to perform all system software modifications, upgrades or changes.

Provide all hardware, software, programming tools and documentation

Page 66: Request for Proposals For - Gujarat State PortalRev)22082013.pdfRequest for Proposals For Appointment of Agency for Design, Site Preparation, Supply, Installation and Maintenance of

CSITMS Gujarat Project Confidential

66

necessary to modify the fire alarm system on site. Modification includes

addition and deletion of devices, circuits, zones and changes to system

operation and custom label changes for devices or zones. The system

structure and software shall place no limit on the type or extent of

software modifications on-site.

d. Guaranty / Warranty

All work performed and all material and equipment furnished under this contract shall be free from defects and shall remain so for the warranty period of one year and AMC period of three years.

A The contractor shall have the ability to provide parts and labor to expand the system specified, if so requested, for a period of 5 years from the date of acceptance.

g. Approvals

i. The system shall have proper listing and/or approval from the following nationally recognized agencies:

UL Underwriters Laboratories Inc FM Factory Mutual

ii. The fire alarm control panel shall meet UL Standard 864 (Control Units) and UL Standard 1076 (Proprietary Burglar Alarm Systems).

iii.The system shall be listed by the national agencies as suitable for extinguishing release applications.

Products

a. Equipments and Material

All equipment and components shall be new, and the manufacturer’s current

model. The materials, appliances, equipment and devices shall be tested and listed by a nationally recognized approvals agency for use as part of a protective signaling system, meeting the National Fire Alarm Code.

ii. All equipment and components shall be installed in strict compliance with

manufacturers' recommendations. Consult the manufacturer's installation manuals for all wiring diagrams, schematics, physical equipment sizes, etc.,

Page 67: Request for Proposals For - Gujarat State PortalRev)22082013.pdfRequest for Proposals For Appointment of Agency for Design, Site Preparation, Supply, Installation and Maintenance of

CSITMS Gujarat Project Confidential

67

before beginning system installation.

iii. All equipment shall be attached to walls and ceiling/floor assemblies and

shall be held firmly in place (e.g., detectors shall not be supported solely by suspended ceilings). Fasteners and supports shall be adequate to support the required load.

c. Conduit and Wire

i. Conduit:

Conduit shall be in accordance with The National Electrical Code (NEC), local and state requirements.

Where required, all wiring shall be installed in conduit or raceway. Conduit fill shall not exceed 40 percent of interior cross sectional area where three or more cables are contained within a single conduit.

Jelly cable should be use so that Rat doesn’t cut it. Cable must be separated from any open conductors of power, or Class 1 circuits, and shall not be placed in any conduit, junction box or raceway containing these conductors, per NEC Article 760-29. All the conduits should be separate.

Wiring for 24 volt DC control, alarm notification, emergency communication and similar power-limited auxiliary functions may be run in the same conduit as initiating and signaling line circuits. All circuits shall be provided with transient suppression devices and the system shall be designed to permit simultaneous operation of all circuits without interference or loss of signals. Cabling should be such a way that in future there is no need of digging.

Conduit shall not enter the fire alarm control panel or any other remotely mounted control panel equipment or back boxes, except where conduit entry is specified by the FACP manufacturer. Different colored conduits needed for Data cables and Electrical connectors.

Conduit shall be 3/4-inch (19.1 mm) minimum.

ii. Wire

All fire alarm system wiring shall be new.

Wiring shall be in accordance with local, state and national codes (e.g., NEC Article 760) and as recommended by the manufacturer of the fire alarm

Page 68: Request for Proposals For - Gujarat State PortalRev)22082013.pdfRequest for Proposals For Appointment of Agency for Design, Site Preparation, Supply, Installation and Maintenance of

CSITMS Gujarat Project Confidential

68

system. Number and size of conductors shall be as recommended by the fire alarm system manufacturer, but not less than 18 AWG (1.02 mm) for Initiating Device Circuits and Signaling Line Circuits, and 14 AWG (1.63 mm) for Notification Appliance Circuits.

All wire and cable shall be listed and/or approved by a recognized testing agency for use with a protective signaling system.

Wire and cable not installed in conduit shall have a fire resistance rating suitable for the installation as indicated in NFPA 70 (e.g., FPLR).

Wiring used for the multiplex communication circuit (SLC) shall be twisted and unshielded and support a minimum wiring distance of 12,500 feet. The design of the system shall permit use of IDC and NAC wiring in the same conduit with the SLC communication circuit.

All field wiring shall be electrically supervised for open circuit and ground fault.

The fire alarm control panel shall be capable of t-tapping Class B (NFPA Style 4) Signaling Line Circuits (SLCs). Systems that do not allow or have restrictions in, for example, the amount of t-taps, length of t-taps etc., are not acceptable.

c. Terminal Boxes, Junction Boxes and Cabinets:

All boxes and cabinets shall be UL listed for their use and purpose.

Initiating circuits shall be arranged to serve like categories (manual, smoke, waterflow). Mixed category circuitry shall not be permitted except on signaling line circuits connected to intelligent reporting devices.

The fire alarm control panel shall be connected to a separate dedicated branch circuit, maximum 20 amperes. This circuit shall be labeled at the main power distribution panel as FIRE ALARM. Fire alarm control panel primary power wiring shall be 12 AWG. The control panel cabinet shall be grounded securely to either a cold water pipe or grounding rod.

Main Fire Alarm Control Panel or Network Node

a. Main FACP or network node shall be a Two Loop Panel and shall contain a

microprocessor based Central Processing Unit (CPU) and power supply in an economical space saving single board design. The CPU shall communicate with

Page 69: Request for Proposals For - Gujarat State PortalRev)22082013.pdfRequest for Proposals For Appointment of Agency for Design, Site Preparation, Supply, Installation and Maintenance of

CSITMS Gujarat Project Confidential

69

and control the following types of equipment used to make up the system: intelligent addressable smoke and thermal (heat) detectors, addressable modules, printer, enunciators, and other system controlled devices.

b. Operator Control

i. Acknowledge Switch:

Activation of the control panel acknowledge switch in response to new alarms and/or troubles shall silence the local panel piezo electric signal and change the alarm and trouble LEDs from flashing mode to steady-ON mode. If multiple alarm or trouble conditions exist, depression of this switch shall advance the LCD display to the next alarm or trouble condition.

Depression of the Acknowledge switch shall also silence all remote annunciator piezo sounders.

ii. Alarm Silence Switch:

Activation of the alarm silence switch shall cause all programmed alarm

notification appliances and relays to return to the normal condition after an

alarm condition. The selection of notification circuits and relays that are

silenceable by this switch shall be fully field programmable within the confines

of all applicable standards. The FACP software shall include silence inhibit and

auto-silence timers.

iii. Alarm Activate (Drill) Switch:

The Alarm Activate switch shall activate all notification appliance circuits. The drill function shall latch until the panel is silenced or reset.

iv. System Reset Switch:

Activation of the System Reset switch shall cause all electronically-latched initiating devices, appliances or software zones, as well as all associated output devices and circuits, to return to their normal condition.

v. Lamp Test:

The Lamp Test switch shall activate all local system LEDs, light each segment of

the liquid crystal display and display the panel software revision for service

personal.

Page 70: Request for Proposals For - Gujarat State PortalRev)22082013.pdfRequest for Proposals For Appointment of Agency for Design, Site Preparation, Supply, Installation and Maintenance of

CSITMS Gujarat Project Confidential

70

c. System Capacity and General Operation

i. The control panel or each network node shall provide, or be capable of

expansion to 636 intelligent/addressable devices. ii. The control panel or each network node shall include Form-C alarm,

trouble, supervisory, and security relays rated at a minimum of 2.0 amps @ 30 VDC. It shall also include four Class B (NFPA Style Y) or Class A (NFPA Style Z) programmable Notification Appliance Circuits.

iii. The control panel or each network node shall support up to 8 additional output modules (signal, speaker, telephone, or relay), each with 8 circuits for an additional 64 circuits. These circuits shall be either Class A (NFPA Style Z) or Class B (NFPA Style Y) per the project drawings.

iv. The system shall include a full featured operator interface control and annunciation panel that shall include a backlit Liquid Crystal Display (LCD), individual color coded system status LEDs, and an alphanumeric keypad with easy touch rubber keys for the field programming and control of the fire alarm system.

v. The system shall be programmable, configurable, and expandable in the field without the need for special tools, PROM programmers or PC based programmers. It shall not require replacement of memory ICs to facilitate programming changes.

vi. The system shall allow the programming of any input to activate any output or group of outputs. Systems that have limited programming (such as general alarm), have complicated programming (such as a diode matrix), or require a laptop personal computer are not considered suitable substitutes.

vii. The FACP shall support up to 20 logic equations, including "and," "or," and "not," or time delay equations to be used for advanced programming. Logic equations shall require the use of a PC with a software utility designed for programming.

viii. The FACP or each network node shall provide the following features:

a. Drift compensation to extend detector accuracy over life. Drift compensation shall also include a smoothing feature, allowing transient noise signals to be filtered out.

b. Detector sensitivity test, meeting requirements of NFPA 72, Chapter 7. c. Maintenance alert, with two levels (maintenance alert/maintenance

urgent), to warn of excessive smoke detector dirt or dust accumulation. - Nine sensitivity levels for alarm, selected by detector. The alarm level

Page 71: Request for Proposals For - Gujarat State PortalRev)22082013.pdfRequest for Proposals For Appointment of Agency for Design, Site Preparation, Supply, Installation and Maintenance of

CSITMS Gujarat Project Confidential

71

range shall be .5 to 2.35 percent per foot for photoelectric detectors

and 0.5 to 2.5 percent per foot for ionization detectors. The system

shall also support sensitive advanced detection laser detectors with an

alarm level range of .03 percent per foot to 1.0 percent per foot. The

system shall also include up to nine levels of Prealarm, selected by

detector, to indicate impending alarms to maintenance personnel. - The ability to display or print system reports. - Alarm verification, with counters and a trouble indication to alert

maintenance personnel when a detector enters verification 20 times. - PAS presignal, meeting NFPA 72 3-8.3 requirements. - Rapid manual station reporting (under 3 seconds) and shall meet

NFPA 72 Chapter 1 requirements for activation of notification circuits within 10 seconds of initiating device activation.

- Periodic detector test, conducted automatically by the software. - Self optimizing pre-alarm for advanced fire warning, which allows

each detector to learn its particular environment and set its prealarm level to just above normal peaks.

- Cross zoning with the capability of counting: two detectors in alarm, two software zones in alarm, or one smoke detector and one thermal detector.

- Walk test, with a check for two detectors set to same address. - Control-by-time for non-fire operations, with holiday schedules. - Day/night automatic adjustment of detector sensitivity. - Device blink control for sleeping areas.

ix. The FACP shall be capable of coding main panel node notification circuits

in March Time (120 PPM), Temporal (NFPA 72 A-2-2.2.2), and California Code. Panel notification circuits (NAC 1, 2,3 and 4) shall also support Two-Stage operation, Canadian Dual Stage (3 minutes) and Canadian Dual Stage (5 minutes). Two stage operation shall allow 20 Pulses Per Minute (PPM) on alarm and 120 PPM after 5 minutes or when a second device activates. Canadian Dual stage is the same as Two-Stage except will only switch to second stage by activation of Drill Switch 3 or 5 minute timer. The panel shall also provide a coding option that will synchronize specific strobe lights designed to accept a specific "sync pulse."

d. Network Communication

The network architecture shall be based on a Local Area Network (LAN), a firmware package that utilizes a peer-to-peer, inherently regenerative communication format and protocol. The protocol shall be based on ARCNET or equivalent. The network shall use a deterministic token-

Page 72: Request for Proposals For - Gujarat State PortalRev)22082013.pdfRequest for Proposals For Appointment of Agency for Design, Site Preparation, Supply, Installation and Maintenance of

CSITMS Gujarat Project Confidential

72

passing method. Collision detection and recovery type protocols are not acceptable substitutes due to life safety requirements. In addition, there shall be no master, polling computer, central file computer, display controller or other central element (weak link) in the network which, on failure, may cause complete loss of network communications or cause major degradation of network capability. There shall be no cascading of CPUs or master-slave relationships at the network level to facilitate network communications. Failure of any node shall not cause failure or communication degradation of any other node or change the network communication protocol among surviving nodes located within distance limitations. Each node/panel shall communicate on the network at a baud rate of not less than 312 KBPS (kilo bits per second). A node may be an intelligent Fire Alarm Control Panel (FACP), Network Control Station PC (NCS) or Network Control Annunciator (NCA). The network shall be capable of expansion to at least 100 nodes.

Each network node address shall be capable of storing Event equations. The event equations shall be used to activate outputs on one network node from inputs on other network nodes.

The network shall be capable of communicating via wire or fiber optic medium. A wire network shall include a fail-safe means of isolating the nodes in the unlikely event of complete power loss to a node.

A network repeater shall be available to increase the twisted-pair distance capability in 3,000 ft. increments.

e. Central Microprocessor

i. The microprocessor shall be a state-of-the-art, high speed, 16-bit RISC device

and it shall communicate with, monitor and control all external interfaces. It shall include an EPROM for system program storage, Flash memory for building-specific program storage, and a "watch dog" timer circuit to detect and report microprocessor failure.

ii. The microprocessor shall contain and execute all control-by-event programs

for specific action to be taken if an alarm condition is detected by the system.

Control-by-event equations shall be held in non-volatile programmable

memory, and shall not be lost even if system primary and secondary power

failure occurs.

iii. The microprocessor shall also provide a real-time clock for time annotation of

Page 73: Request for Proposals For - Gujarat State PortalRev)22082013.pdfRequest for Proposals For Appointment of Agency for Design, Site Preparation, Supply, Installation and Maintenance of

CSITMS Gujarat Project Confidential

73

system displays, printer, and history file. The time-of-day and date shall not be lost if system primary and secondary power supplies fail. The real time clock may also be used to control non-fire functions at programmed time-of-day, day-of-week, and day-of-year.

iv. A special program check function shall be provided to detect common operator errors.

v. An auto-program (self-learn) function shall be provided to quickly install initial

functions and make the system operational.

vi. For flexibility and to ensure program validity, an optional Windows(TM) based

program utility shall be available. This program shall be used to off-line program the system with batch upload/download, and have the ability to upgrade the manufacturers (FLASH) system code changes. This program shall also have a verification utility, which scans the program files, identifying possible errors. It shall also have the ability to compare old program files to new ones, identifying differences in the two files to allow complete testing of any system operating changes. This shall be in incompliance with the NFPA 72 requirements for testing after system modification.

f. System Display

i. The system shall support the following display mode options:

80 Character display option. The display shall include an 80-character backlit alphanumeric Liquid Crystal Display (LCD) and a full PC style QWERTY keypad.

ii. The display shall provide all the controls and indicators used by the system

operator:

The 80-character display shall include the following operator control switches: ACKNOWLEDGE, ALARM SILENCE, ALARM ACTIVATE (drill), SYSTEM RESET, and LAMP TEST.

iii. The display shall annunciate status information and custom alphanumeric

labels for all intelligent detectors, addressable modules, internal panel circuits, and software zones.

iv. The display shall also provide Light-Emitting Diodes.

Page 74: Request for Proposals For - Gujarat State PortalRev)22082013.pdfRequest for Proposals For Appointment of Agency for Design, Site Preparation, Supply, Installation and Maintenance of

CSITMS Gujarat Project Confidential

74

v. The 80-character display shall provide 8 Light-Emitting-Diodes (LEDs) that indicate the status of the following system parameters: AC POWER, FIRE ALARM, PREALARM WARNING, SECURITY ALARM, SUPERVISORY SIGNAL, SYSTEM TROUBLE, DISABLED POINTS, and ALARM SILENCED.

vi. The 80-character display keypad shall be an easy to use QWERTY type keypad,

similar to a PC keyboard. This shall be part of the standard system and have the capability to command all system functions, entry of any alphabetic or numeric information, and field programming. Two different password levels shall be provided to prevent unauthorized system control or programming.

vii. The system shall support the display of battery charging current and voltage

on the 80-character LCD display.

g. Signaling Line Circuits (SLC)

Each FACP or FACP network node shall support up to two SLCs. Each SLC

interface shall provide power to and communicate with up to 125 intelligent

detectors (ionization, photoelectric or thermal) and 125 intelligent modules

(monitor or control) for a loop capacity of 400 detectors. The addition of the

optional second loop shall double the device capacity, Panel should have

expansion capacity. Each SLC shall be capable of NFPA 72 Style 4, Style 6, or

Style 7 (Class A or B) wiring.

CPU shall receive analog information from all intelligent detectors to be processed to determine whether normal, alarm, prealarm, or trouble conditions exist for each detector. The software shall automatically maintain the detector's desired sensitivity level by adjusting for the effects of environmental factors, including the accumulation of dust in each detector. The analog information shall also be used for automatic detector testing and for the automatic determination of detector maintenance requirements.

h. Serial Interfaces

The system shall include two serial EIA-232 interfaces. Each interface shall be a means of connecting UL Listed Information Technology Equipment (ITE) peripherals.

i. Notification Appliance Circuit (NAC) Module

The Notification Appliance Circuit module shall provide four fully supervised Class A or B (NFPA Style Z or Y) notification circuits. An expansion circuit board shall allow expansion to eight circuits per module.

Page 75: Request for Proposals For - Gujarat State PortalRev)22082013.pdfRequest for Proposals For Appointment of Agency for Design, Site Preparation, Supply, Installation and Maintenance of

CSITMS Gujarat Project Confidential

75

The notification circuit capacity shall be 3.0 amperes maximum per circuit and 6.0 amperes maximum per module.

The module shall not affect other module circuits in any way during a short circuit condition.

The module shall provide eight green ON/OFF LEDs and eight yellow trouble LEDs.

The module shall also provide a momentary switch per circuit that may be used to manually turn the particular circuit on or off or to disable the circuit.

Each notification circuit shall include a custom label inserted to identify each circuit's location. Labels shall be created using a standard typewriter or word processor.

The notification circuit module shall be provided with removable wiring terminal blocks for ease of installation and service. The terminal strips shall be UL listed for use with up to 12 AWG wire.

Each circuit shall be capable of, through system programming, deactivating upon depression of the signal silence switch.

j. Control Relay Module

The control relay module shall provide four Form-C auxiliary relay circuits rated at 5 amperes, 28 VDC. An expansion circuit board shall allow expansion to eight Form-C relays per module.

Each relay circuit shall be capable of being activated (change in state) by any initiating device or from any combination of initiating devices.

The relay module shall provide 8 green ON/OFF LEDs and 8 yellow LEDs (indicates disabled status of the relay).

The module shall provide a momentary switch per relay circuit that may be used to manually turn the relay ON/OFF or to disable the relay.

Each relay circuit shall include a custom label inserted to identify its location. Labels shall be created using a standard typewriter or word processor. The control relay module shall be provided with removable wiring terminal blocks for ease of installation and service. The terminal blocks shall be UL listed for use with up to 12 AWG wire.

Page 76: Request for Proposals For - Gujarat State PortalRev)22082013.pdfRequest for Proposals For Appointment of Agency for Design, Site Preparation, Supply, Installation and Maintenance of

CSITMS Gujarat Project Confidential

76

k. Enclosures:

The control panel shall be housed in a UL-listed cabinet suitable for surface or semi-flush mounting. The cabinet and front shall be corrosion protected, given a rust-resistant prime coat, and manufacturer's standard finish.

The back box and door shall be constructed of 0.060 steel with provisions for electrical conduit connections into the sides and top.

The door shall provide a key lock and shall include a glass or other transparent opening for viewing of all indicators. For convenience, the door may be site configured for either right or left hand hinging.

l. Power Supply:

A high tech off-line switching power supply shall be available for the fire alarm control panel or network node and provide 6.0 amps of available power for the control panel and peripheral devices.

Provisions will be made to allow the audio-visual power to be increased as required by adding modular expansion audio-visual power supplies.

Positive-Temperature-Coefficient (PTC) thermistors, circuit breakers, or other over-current protection shall be provided on all power outputs. The power supply shall provide an integral battery charger for use with batteries up to 60 AH or may be used with an external battery and charger system. Battery arrangement may be configured in the field.

The power supply shall continuously monitor all field wires for earth ground conditions, and shall have the following LED indicators:

Ground Fault LED AC Power Fail LED NAC on LED (4)

The main power supply shall operate on 120 VAC, 60 Hz, and shall provide all necessary power for the FACP.

The main power supply shall provide a battery charger using dual-rate charging

techniques for fast battery recharge and be capable of charging batteries up to 60

AH.

Page 77: Request for Proposals For - Gujarat State PortalRev)22082013.pdfRequest for Proposals For Appointment of Agency for Design, Site Preparation, Supply, Installation and Maintenance of

CSITMS Gujarat Project Confidential

77

All circuits shall be power-limited, per UL864 requirements.

m. Field Charging Power Supply (FCPS): The FCPS is a device designed for use as

either a remote 24 volt power supply or used to power Notification Appliances.

The FCPS shall offer up to 6.0 amps (4.0 amps continuous) of regulated 24 volt power. It shall include an integral charger designed to charge 7.0 amp hour batteries and to support 60 hour standby.

The Field Charging Power Supply shall have two input triggers. The input trigger shall be a Notification Appliance Circuit (from the fire alarm control panel) or a relay. Four outputs (two Style Y or Z and two style Y) shall be available for connection to the Notification devices.

The FCPS shall include an attractive surface mount back box.

The Field Charging Power Supply shall include the ability to delay the AC fail delay per NFPA requirements.

The FCPS include power limited circuitry, per 1995 UL standards.

n. Specific System Operations

i. Smoke Detector Sensitivity Adjust: A means shall be provided for adjusting

the sensitivity of any or all addressable intelligent detectors in the system from the system keypad. Sensitivity range shall be within the allowed UL window and have a minimum of 9 levels.

ii. Alarm Verification: Each of the intelligent addressable smoke detectors in the

system may be independently selected and enabled to be an alarm verified detector. The alarm verification delay shall be programmable from 5 to 30 seconds and each detector shall be able to be selected for verification. The FACP shall keep a count of the number of times that each detector has entered the verification cycle. These counters may be displayed and reset by the proper operator commands.

iii. Point Disable: Any addressable device or conventional circuit in the system

may be enabled or disabled through the system keypad.

iv. Point Read: The system shall be able to display or print the following point

status diagnostic functions: a. Device status

Page 78: Request for Proposals For - Gujarat State PortalRev)22082013.pdfRequest for Proposals For Appointment of Agency for Design, Site Preparation, Supply, Installation and Maintenance of

CSITMS Gujarat Project Confidential

78

b. Device type c. Custom device label d. View analog detector values e. Device zone assignments f. All program parameters

v. System Status Reports: Upon command from an operator of the system, a

status report will be generated and printed, listing all system status.

vi. System History Recording and Reporting: The fire alarm control panel shall

contain a history buffer that will be capable of storing up to 800 events. Up to 200 events shall be dedicated to alarm and the remaining events are general purpose. Systems that do not have dedicated alarm storage, where events are overridden by non-alarm type events, are not suitable substitutes. Each of these activations will be stored and time and date stamped with the actual time of the activation. The contents of the history buffer may be manually reviewed, one event at a time, or printed in its entirety. The history buffer shall use non-volatile memory. Systems that use volatile memory for history storage are not acceptable substitutes.

vii. Automatic Detector Maintenance Alert: The fire alarm control panel shall

automatically interrogate each intelligent detector and shall analyze the

detector responses over a period of time. If any intelligent detector in the

system responds with a reading that is above or below normal limits, then the

system will enter the trouble mode, and the particular detector will be

annunciated on the system display, and printed on the optional printer. This

feature shall in no way inhibit the receipt of alarm conditions in the system,

nor shall it require any special hardware, special tools or computer expertise

to perform.

viii. Pre-Alarm Function: The system shall provide two levels of pre-alarm warning

to give advance notice of a possible fire situation. Both pre-alarm levels shall be fully field adjustable. The first level shall give an audible indication at the panel. The second level shall give an audible indication and may also activate control relays. The system shall also have the ability to activate local detector sounder bases at the pre-alarm level, to assist in avoiding nuisance alarms.

ix. Software Zones: The FACP shall provide 100 software zones, 10 additional

special function zones, 10 releasing zones, and 20 logic zones.

x. The fire alarm control panel shall include a walk test feature. It shall include the

Page 79: Request for Proposals For - Gujarat State PortalRev)22082013.pdfRequest for Proposals For Appointment of Agency for Design, Site Preparation, Supply, Installation and Maintenance of

CSITMS Gujarat Project Confidential

79

ability to test initiating device circuits and notification appliance circuits from the field without returning to the panel to reset the system. Operation shall be as follows: Alarming an initiating device shall activate programmed outputs, which are selected to participate in walk test, for 3 seconds.

Introducing a trouble into the initiating device shall activate the programmed outputs for 8 seconds.

All devices tested in walk test shall be recorded in the history buffer.

xi. Water flow Operation: An alarm from a waterflow detection device shall activate the appropriate alarm message on the main panel display, turn on all programmed notification appliance circuits and shall not be affected by the signal silence switch.

xii. Supervisory Operation: An alarm from a supervisory device shall cause the

appropriate indication on the system display, light a common supervisory LED, but will not cause the system to enter the trouble mode.

xiii. Signal Silence Operation: The FACP shall have the ability to program each

output circuit (notification, relay, speaker etc) to deactivate upon depression of the signal silence switch.

Xiv.Non-Alarm Input Operation: Any addressable initiating device in the system may be used as a non-alarm input to monitor normally open contact type devices. Non-alarm functions are a lower priority than fire alarm initiating devices.

xv. Combo Zone: A special type code shall be available to allow water flow and

supervisory devices to share a common addressable module. Water flow devices shall be wired in parallel, supervisory devices in series.

System Components

a. Speakers:

i. All speakers shall operate on 25 VRMS or with field selectable output taps

from 0.5 to 2.0 Watts.

Page 80: Request for Proposals For - Gujarat State PortalRev)22082013.pdfRequest for Proposals For Appointment of Agency for Design, Site Preparation, Supply, Installation and Maintenance of

CSITMS Gujarat Project Confidential

80

ii. Speakers in corridors and public spaces shall produce a nominal sound output

of 84 dBA at 10 feet (3m).

iv. Frequency response shall be a minimum of 400 HZ to 4000 HZ.

v. The back of each speaker shall be sealed to protect the speaker cone from

damage and dust.

b. Projected Beam Detectors

i. The projected beam type shall be a 4-wire 24 VDC device.

ii. The detector shall be listed to UL 268 and shall consist of a separate

transmitter and receiver capable of being powered separately or together.

iii. The detector shall operate in either a short range (30' - 100') or long range

(100' - 330') mode.

iv. The temperature range of the device shall be -22 degrees F to 131 degrees F.

v. The detector shall feature a bank of four alignment LEDs on both the

receiver and the transmitter that are used to ensure proper alignment of unit without special tools.

vi. Beam detectors shall feature automatic gain control which will compensate

for gradual signal deterioration from dirt accumulation on lenses.

vii. The unit shall be both ceiling and wall mountable.

c. Alphanumeric LCD Type Annunciator

i. The alphanumeric display annunciator shall be a supervised, remotely

located back-lit LCD display containing a minimum of eighty (80) characters for alarm annunciation in clear English text.

ii. The LCD annunciator shall display all alarm and trouble conditions in the

system.

iii. An audible indication of alarm shall be integral to the alphanumeric display.

iv. The display shall be UL listed for fire alarm application.

Page 81: Request for Proposals For - Gujarat State PortalRev)22082013.pdfRequest for Proposals For Appointment of Agency for Design, Site Preparation, Supply, Installation and Maintenance of

CSITMS Gujarat Project Confidential

81

v. It shall be possible to connect up to 32 LCD displays and be capable of wiring distances up to 6,000 feet from the control panel.

vi. The annunciator shall connect to a separate, dedicated "terminal mode" EIA-

485 interface. This is a two-wire loop connection and shall be capable of distances to 6,000 feet. Each terminal mode LCD display shall mimic the main control panel.

vii. The system shall allow a minimum of 32 terminal mode LCD annunciators. Up

to 10 LCD annunciators shall be capable of the following system functions: Acknowledge, Signal Silence and Reset, which shall be protected from unauthorized use by a key switch or password.

d. All interfaces and associated equipment are to be protected so that they will

not be affected by voltage surges or line transients consistent with UL standard 864.

e. Field Wiring Terminal Blocks

For ease of service all panel I/O wiring terminal blocks shall be removable, plug-in types and have sufficient capacity for #18 to #12 AWG wire. Terminal blocks that are permanently fixed are not acceptable.

System Components – Addressable Devices

a. Addressable Devices - General

i. Addressable devices shall use simple to install and maintain decade, decimal

address switches. Devices shall be capable of being set to an address in a range of 001 to 159.

ii. Addressable devices, which use a binary-coded address setting method, such as a DIP-switch, are not an allowable substitute.

iii. Detectors shall be intelligent (analog) and addressable, and shall connect with

two wires to the fire alarm control panel Signaling Line Circuits.

iv. Addressable smoke and thermal detectors shall provide dual alarm and power

/ polling LEDs. Both LEDs shall flash green under normal conditions, indicating that the detector is operational and in regular communication with the control panel, and both LEDs shall be placed into steady red illumination by

Page 82: Request for Proposals For - Gujarat State PortalRev)22082013.pdfRequest for Proposals For Appointment of Agency for Design, Site Preparation, Supply, Installation and Maintenance of

CSITMS Gujarat Project Confidential

82

the control panel, indicating that an alarm condition has been detected. If required, the LED flash shall have the ability to be removed from the system program. An output connection shall also be provided in the base to connect an external remote alarm LED.

v. The fire alarm control panel shall permit detector sensitivity adjustment

through field programming of the system. The panel on a time-of-day basis shall automatically adjust sensitivity.

vi. Using software in the FACP, detectors shall automatically compensate for dust

accumulation and other slow environmental changes that may affect their performance. The detectors shall be listed by UL as meeting the calibrated sensitivity test requirements of NFPA Standard 72, Chapter 7.

vii. The detectors shall be ceiling-mount and shall include a separate twist-lock

base with tamper proof feature. Bases shall include a sounder base with a built-in (local) sounder rated at 85 DBA minimum, a relay base and an isolator base designed for Style 7 applications.

viii. The detectors shall provide a test means whereby they will simulate an alarm

condition and report that condition to the control panel. Such a test may be initiated at the detector itself (by activating a magnetic switch) or initiated remotely on command from the control panel.

ix. Detectors shall also store an internal identifying type code that the control

panel shall use to identify the type of device (ION, PHOTO, THERMAL).

x. Detectors will operate in an analog fashion, where the detector simply

measures its designed environment variable and transmits an analog value to the FACP based on real-time measured values. The FACP software, not the detector, shall make the alarm/normal decision, thereby allowing the sensitivity of each detector to be set in the FACP program and allowing the system operator to view the current analog value of each detector.

xi. Addressable devices shall store an internal identifying code that the control

panel shall use to identify the type of device.

xii. Addressable modules shall mount in a 4-inch square (101.6 mm square), 2-1/8

inch (54 mm) deep electrical box. An optional surface mount Lexan enclosure shall be available.

Page 83: Request for Proposals For - Gujarat State PortalRev)22082013.pdfRequest for Proposals For Appointment of Agency for Design, Site Preparation, Supply, Installation and Maintenance of

CSITMS Gujarat Project Confidential

83

b. Addressable Manual Fire Alarm Box (manual station)

i. Addressable manual fire alarm boxes shall, on command from the control

panel, send data to the panel representing the state of the manual switch and the addressable communication module status. They shall use a key operated test-reset lock, and shall be designed so that after actual emergency operation, they cannot be restored to normal use except by the use of a key.

ii. All operated stations shall have a positive, visual indication of operation and

utilize a key type reset.

iii. Manual fire alarm boxes shall be constructed of Lexan with clearly visible

operating instructions provided on the cover. The word FIRE shall appear on the front of the stations in raised letters, 1.75 inches (44 mm) or larger.

c. Intelligent Photoelectric Smoke Detector

The detectors shall use the photoelectric (light-scattering) principal to measure smoke density and shall, on command from the control panel, send data to the panel representing the analog level of smoke density.

d. Intelligent Laser Photo Smoke Detector

i. The intelligent laser photo smoke detector shall be a spot type detector that

incorporates an extremely bright laser diode and an integral lens that focuses the light beam to a very small volume near a receiving photo sensor. The scattering of smoke particles shall activate the photo sensor.

ii. The laser detector shall have conductive plastic so that dust accumulation is

reduced significantly.

iii. The intelligent laser photo detector shall have nine sensitivity levels and be

sensitive to a minimum obscuration of 0.03 percent per foot.

iv. The laser detector shall not require expensive conduit, special fittings or PVC

pipe.

v. The intelligent laser photo detector shall support standard, relay, isolator and

sounder detector bases.

vi. The laser photo detector shall not require other cleaning requirements than those listed in NFPA 72. Replacement, refurbishment or specialized cleaning of the detector head shall not be required.

Page 84: Request for Proposals For - Gujarat State PortalRev)22082013.pdfRequest for Proposals For Appointment of Agency for Design, Site Preparation, Supply, Installation and Maintenance of

CSITMS Gujarat Project Confidential

84

vii. The laser photo detector shall include two bicolor LEDs that flash green in

normal operation and turn on steady red in alarm.

e. Intelligent Ionization Smoke Detector

The detectors shall use the dual-chamber ionization principal to measure products of combustion and shall, on command from the control panel, send data to the panel representing the analog level of products of combustion.

f. Intelligent Multi Criteria Acclimating Detector

i. The intelligent multi criteria Acclimate detector shall be an addressable device

that is designed to monitor a minimum of photoelectric and thermal technologies in a single sensing device. The design shall include the ability to adapt to its environment by utilizing a built-in microprocessor to determine its environment and choose the appropriate sensing settings. The detector design shall allow a wide sensitivity window, no less than 1 to 4% per foot obscuration. This detector shall utilize advanced electronics that react to slow smoldering fires and thermal properties all within a single sensing device.

ii. The microprocessor design shall be capable of selecting the appropriate

sensitivity levels based on the environment type it is in (office, manufacturing, kitchen etc.) and then have the ability to automatically change the setting as the environment changes (as walls are moved or as the occupancy changes).

iii. The intelligent multi criteria detection device shall include the ability to

combine the signal of the thermal sensor with the signal of the photoelectric signal in an effort to react hastily in the event of a fire situation. It shall also include the inherent ability to distinguish between a fire condition and a false alarm condition by examining the characteristics of the thermal and smoke sensing chambers and comparing them to a database of actual fire and deceptive phenomena.

g. Intelligent Thermal Detectors

Thermal detectors shall be intelligent addressable devices rated at 135 degrees Fahrenheit (58 degrees Celsius) and have a rate-of-rise element rated at 15 degrees F (9.4 degrees C) per minute. It shall connect via two wires to the fire alarm control panel signaling line circuit.

h. Intelligent Duct Smoke Detector

Page 85: Request for Proposals For - Gujarat State PortalRev)22082013.pdfRequest for Proposals For Appointment of Agency for Design, Site Preparation, Supply, Installation and Maintenance of

CSITMS Gujarat Project Confidential

85

The smoke detector housing shall accommodate either an intelligent ionization detector or an intelligent photoelectric detector, of that provides continuous analog monitoring and alarm verification from the panel.

When sufficient smoke is sensed, an alarm signal is initiated at the FACP, and appropriate action taken to change over air handling systems to help prevent the rapid distribution of toxic smoke and fire gases throughout the areas served by the duct system.

i. Addressable Dry Contact Monitor Module

Addressable monitor modules shall be provided to connect one supervised DC zone of conventional alarm initiating devices (any N.O. dry contact device) to one of the fire alarm control panel SLCs.

The DC zone shall be suitable for Style D or Style B operation. An LED shall be provided that shall flash under normal conditions, indicating that the monitor module is operational and in regular communication with the control panel.

For difficult to reach areas, the monitor module shall be available in a miniature package and shall be no larger than 2-3/4 inch (70 mm) x 1-1/4 inch (31.7 mm) x 1/2 inch (12.7 mm). This version need not include Style D or an LED.

j. Two Wire Detector Monitor Module

Addressable monitor modules shall be provided to connect one supervised IDC zone of conventional 2-wire smoke detectors or alarm initiating devices (any N.O. dry contact device).

The DC zone may be wired for Class A or B (Style D or Style B) operation. An LED shall be provided that shall flash under normal conditions, indicating that the monitor module is operational and in regular communication with the control panel.

k. Addressable Control Module

Addressable control modules shall be provided to supervise and control the operation of one conventional NACs of compatible, 24 VDC powered, polarized audio/visual notification appliances.

Audio/visual power shall be provided by a separate supervised power circuit from the main fire alarm control panel or from a supervised UL listed remote power supply.

Page 86: Request for Proposals For - Gujarat State PortalRev)22082013.pdfRequest for Proposals For Appointment of Agency for Design, Site Preparation, Supply, Installation and Maintenance of

CSITMS Gujarat Project Confidential

86

The control module shall be suitable for pilot duty applications and rated for a minimum of 0.6 amps at 30 VDC.

l. Addressable Relay Module

Addressable Relay Modules shall be available for HVAC control and other

building functions. The relay shall be form C and rated for a minimum of 2.0

Amps resistive or 1.0 Amps inductive. The relay coil shall be magnetically

latched to reduce wiring connection requirements, and to insure that 100% of

all auxiliary relay or NACs may be energized at the same time on the same pair

of wires.

m. Isolator Module

Isolator modules shall be provided to automatically isolate wire -to-wire short circuits on an SLC Class A or Class B branch. The isolator module shall limit the number of modules or detectors that may be rendered inoperative by a short circuit fault on the SLC loop segment or branch. At least one isolator module shall be provided for each floor or protected zone of the building.

If a wire-to-wire short occurs, the isolator module shall automatically open-circuit (disconnect) the SLC. When the short circuit condition is corrected, the isolator module shall automatically reconnect the isolated section.

The isolator module shall not require address-setting, and its operations shall be totally automatic. It shall not be necessary to replace or reset an isolator module after its normal operation.

The isolator module shall provide a single LED that shall flash to indicate that the isolator is operational and shall illuminate steadily to indicate that a short circuit condition has been detected and isolated.

Batteries

The battery shall have sufficient capacity to power the fire alarm system for not less than twenty-four hours plus 5 minutes of alarm upon a normal AC power failure.

The batteries are to be completely maintenance free. No liquids are required. Fluid level checks for refilling, spills, and leakage shall not be required.

If necessary to meet standby requirements, external battery and charger

Page 87: Request for Proposals For - Gujarat State PortalRev)22082013.pdfRequest for Proposals For Appointment of Agency for Design, Site Preparation, Supply, Installation and Maintenance of

CSITMS Gujarat Project Confidential

87

systems may be used.

7.5 Internal CCTV system

All system and components shall have been thoroughly tested and proven in actual use. All the cameras should be IP based Indoor dome / Box camera (Whatever required) with a Network Video Recorder (NVR) or Server with storage capacity of 30 days. The CCTV system for the CONTROL ROOM should be ISOLATED and SEPRATE from the city CCTV network. Specifications included in this section are inductive and considered as minimum; components and software that shall be acquired at the time of implementing the project shall be the latest versions available in the market. Camera requirement:

The camera should be IP based Indoor Dome / Box with 2.8 ~ 12 mm verifocal lens with minimum resolution of 1 Megapixel. Camera should carry all the accessories and mounting equipments required to make it installed and live. The camera should provide high picture quality through Digital signal Processing and real color picture through ATW. The camera should work with minimum illumination of 0.1 lux @ F1.2. 30 IRE, AGC on condition. The camera should be CE/FCC certified. Vendor has to provide Server / Workstation with 22” LCD for monitoring purpose.

Page 88: Request for Proposals For - Gujarat State PortalRev)22082013.pdfRequest for Proposals For Appointment of Agency for Design, Site Preparation, Supply, Installation and Maintenance of

CSITMS Gujarat Project Confidential

88

8.0 City wise Command and Control Centre

8.1 Workstation

Specifications

Form factor Small form factor or Desktop or Tower

CPU 1 * 3rd gen Intel Core processor i7-3770, 3 GHz, 8 MB cache, 1333 MHz memory, Quad-Core, HT, Turbo or

equivalent or higher

Chipset Intel® Q77 Express or equivalent or higher

Memory 16GB(4x4GB) DDR3-1333MHz memory scalable up to

32 GB

Bays 1 internal 3.5" bay, and 1 shared with external 3.5"

bay. 1 external 5.25" bay.

Hard disk 2 * 1TB SATA 7200 rpm 3Gbps 3.5" HDD

Graphics NVIDIA Quadro 600 1GB memory PCIe Graphics Card

or equivalent or higher with dual display port

Networking Integrated Gigabit Ethernet Card with Management

capabilities WOL, PXE 2.1 and AMT 6.0

Ports 4 USB 2.0 or 3.0, optional IEEE 1394: 1 Front, 1 Rear (rear via optional card, front port via 19-in-1 MCR), 1

audio out, and 1 microphone/ 2nd headphone.

Other 22” LCD monitor with 1280 x 1024 or greater display

resolution, Keyboard & optical scroll mouse

Page 89: Request for Proposals For - Gujarat State PortalRev)22082013.pdfRequest for Proposals For Appointment of Agency for Design, Site Preparation, Supply, Installation and Maintenance of

CSITMS Gujarat Project Confidential

89

Bus Slots 1 PCI Express x16 Gen2 / Gen 3

1 PCIe Gen1/Gen2 slot x16 mechanical / x4 electrical

1 PCIe Gen1 slot x1 mechanical/x1 electrical

Optical drive Internal DVD Writer

Industry Standard Compliance ACPI 2.0b Compliant, PCI 2.2 Compliant, WOL

Support, Microsoft® Logo certifications, PXE Support, USB 2.0 and 3.0 Compliant

Operating System Windows7 64 bit OS or latest with media

8.2 USB Joystick

Basic Design

The joystick shall be USB with Hall Effect specifically designed to provide the network video controlling with responsive and accurate pan/tilt/zoom camera positioning controls.

Device Support The device shall support the camera makes mentioned in the RFP

Software Support Can be integrated seamlessly with any video surveillance software platform recognizing joystick inputs via Microsoft's DirectX.

Switches and ports Six programmable switches and USB Port

Storage Temperature 0° to 50°C

Humidity 0 to 85%

Compliance RoHS Compliance

Power Supply required +5VDC

8.3 Server

Server

Redundant Clustered Servers

If one server fails, the second server must perform all the operation

automatically. (Minimum two server for each setup)

Page 90: Request for Proposals For - Gujarat State PortalRev)22082013.pdfRequest for Proposals For Appointment of Agency for Design, Site Preparation, Supply, Installation and Maintenance of

CSITMS Gujarat Project Confidential

90

Chassis Rack Mountable

CPU 2 * Eight Core Intel Xeon processor E5 Series with minimum 2.0 GHz (E5-2650) or better

Motherboard Intel® C600 Series Chipset with Intel® E5-2600 Processor Family or equivalent or better

Memory 64GB DDR3 Registered (RDIMM) memory 8 x 8GB @1600 MHz scalable up to 384GB. RAM up gradation to 128GB should be without replacing the existing RAM Modules supplied initially.

Memory Protection

Advanced ECC (multi-bit error protection)/ Mirroring mode/ Lockstep mode

Bays 8 (scalable up to 16) Hot Plug 2.5" hard disk bays / 6 Hot Plug 3.5" hard Disk Bays + CDROM/DVD Bay

Hard disk drive 3 X 600GB 15K SAS Hot plug 2.5" HDDs

Controller SAS Raid Controller with RAID 0/1/1+0/0+1/5/5+0 with 1GB Flash backed Write Cache (onboard or in a PCI Express slot).

Networking features

4 Nos of Multifunction Gigabit Ethernet Ports with iSCSI feature. Should support 10Gbps Ethernet ports with iSCSI feature in future.

1 No of Remote Management Ethernet Port

HBA 2 x single port 8Gbps HBAs

Ports Total 5 USB v2.0 or v3.0 ports

Bus Slots Minimum 2 PCIe slots should be free after configuring all requirement mentioned in this technical specifications

Optical drive DVD/CD - RW combo drive

Power Supply n + n Hot swappable Power Supplies for redundancy

Fans Redundant Hot swappable Fans

Operating System

Microsoft Windows latest server OS standard edition

Industry Standard Compliance

ACPI 2.0b Compliant, PCIe 3.0 Compliant, PXE Support, WOL Support, Microsoft® Logo certifications, USB 2.0 Compliant

OS Support Microsoft Windows Server, Red Hat Enterprise Linux (RHEL), SUSE Linux Enterprise Server (SLES), Optional Oracle Enterprise Linux (OEL), All leading virtualization hypervisor support like VMware, Citrix Xen, Windows HyperV etc.

Manageability Features

Dedicated Hardware Controller based Management

Should be able to manage systems through a web-browser

OEM to provide its own systems management software.

SMS or e-Mail alerts should be supported & provided

Pre-failure ALERTS for critical components like CPU, Memory, Hard Disk, RPS & FAN before actual failure of component.

Page 91: Request for Proposals For - Gujarat State PortalRev)22082013.pdfRequest for Proposals For Appointment of Agency for Design, Site Preparation, Supply, Installation and Maintenance of

CSITMS Gujarat Project Confidential

91

It should provide Secure Sockets Layer (SSL) 128 bit encryption and Secure Shell (SSH) Version 2 and support VPN for secure access over internet.

Should be able to generate a report on Inventory

Automatic check & update of hardware drivers & Bios Version Control without any downtime

8.4 Video Wall (3 X 4)

Picture Commercial Grade Direct Vide LCD

Panel

Diagonal Size 42"

Type S-PVA(DID)

Resolution 1366*768

Pixel Pitch(mm) 0.7455(H) * 0.7455(V)

Active Display Area(mm) 1018.353(H) x 572.544(V)

Bezel Width Maximum 6.7 mm between

two LCDs.

Brightness(Typ.) 450 cd/m2

Contrast Ratio 4500:1

Viewing Angle(H/V) 178/178

Response Time(G-to-G) 8ms

Display Colors 8 bit - 16.7M

Color Gamut 72%

Display

Dynamic C/R 10000:1

H-Scanning Frequency 30kHz ~ 81kHz

V-Scanning Frequency 56Hz ~ 85Hz

Maximum Pixel Frequency 148.5MHz

Connectivity

INPUT

RGB Analog D-SUB, DVI-D, Display Port

VIDEO CVBS, HDMI1,HDMI2,

Component(D-sub 15pin)

AUDIO RCA(L/R) , Stereo mini Jack

OUTPUT

RGB DVI-D(Loop-out)

VIDEO N/A

AUDIO Stereo mini Jack

Power Out 5V (for SBB)

Page 92: Request for Proposals For - Gujarat State PortalRev)22082013.pdfRequest for Proposals For Appointment of Agency for Design, Site Preparation, Supply, Installation and Maintenance of

CSITMS Gujarat Project Confidential

92

EXTERNAL CONTROL RS232C(in/out), RJ45

EXTERNAL SENSOR Stero mini jack(IR in/out),

mini USB (Ext. BR/IR sensor)

Power

Type Internal

Power Supply AC 100 - 240 V~ (+/- 10 %), 50/60 Hz

Power Consumption

On Mode 205W(max) / 195W(typ)

Sleep Mode less than 2W

Off Mode less than 1W

Mechanical Spec

Dimension (mm)

Set 1025.7 X 579.8 X 130.0

Package 1148.0 * 705.0 * 330.0

Weight (kg) Set 19.3

Package 24.6

VESA Mount 600*400mm

Protection Glass N/A

Stand Type Foot Stand(optional)

Media Player Option Type N/A

Bezel Width (mm) 4.3mm(U/L), 2.4mm(R/B)

Operation Operating Temperature 0℃~ 40℃

Humidity 10~80%

Accessories Included

Quick Setup Guide, Warranty Card,

Application CD, D-Sub cable, Power Cord,

Remote Controller, Batteries

Video Wall Bracket

CONTROL SYSTEM

2-Series Ethernet Control system that features a built-in Web server and supports a wide variety of control formats, including IR, Rs-232 and TCP/IP. Compact Control

System with Ethernet. Includes PW-2410RU Power Supply-with 8 Channel relay Module with 8 On/Off Relay. Relay contractor with 8 power socket operation with control

system only

SWITCHER & INTERFACE

Matrix Switcher 8 x 8 VGA with Audio Matrix Switcher

Video

Routing 8 x 8 matrix

Video bandwidth 350 MHz

Switching speed Minimum 195 nseo input

Video Inputs 8 VGA-UXGA RGBHV, RGBS, RGsB, RsGsBs, HDTV,

Page 93: Request for Proposals For - Gujarat State PortalRev)22082013.pdfRequest for Proposals For Appointment of Agency for Design, Site Preparation, Supply, Installation and Maintenance of

CSITMS Gujarat Project Confidential

93

component video, S-video, composite video

VIDEO INPUT

Connectors 1 x 15 Min HD female

Impedance 75 Ohms

Control RS-232 control

Matrix Switcher 8 x 8 Composite Video and Audio Matrix Switcher

Video

Routing 8 x 8 matrix switcher

Video bandwidth 150 MHz

VIDEO INPUT

Connectors 1 x Female BNC connectors, audio on captive screw

Control RS-232 control

Distribution Amp 1 Input 2 Output VGA Distribution Amplifier

Bandwidth 350 MHz

Video Input Nominal level 0.7 Vp-p for RGB

Connectors 2 x 15 Pin HD female

Inputs connectors 1 x 15 Pin HD female

Other connectors 3.5 mm captive screw connector

Cables etc.

Cables, Connectors & Patch Cords

RGBHV Cable

RG6/SHR Cable - Video Cable

Two Conductor S-Video Cable - S-Video Cable

RS-232 Cable

Molded VGA patch cord to connect your Laptops/PCs

Various types of A/V connectors

Heat Shrink sleeves - various size and color (Lumpsum)

Rack 22U Equipment rack Black Color Front and Rear Door

Perforated

8.5 Furniture

Typical Work station

Page 94: Request for Proposals For - Gujarat State PortalRev)22082013.pdfRequest for Proposals For Appointment of Agency for Design, Site Preparation, Supply, Installation and Maintenance of

CSITMS Gujarat Project Confidential

94

Providing and fixing work surface as per drawing complete.

With 19 mm plywood laminated on top surface finished with white wood

beading Strip with melamine polish.

Front edge having 19mm ply Strip. Rate also includes wooden Strip for fixing

and cable manager and necessary hardware alongwith providing and fixing

Ebco make key board trey with mouse (350mm size) of metal.

Storage Unit (2.5' X 1.5')

Providing and fixing storage unit of 19mm thick BWR ecotach or kitply gold

ply only back side is having 6mm thick ply of same make, having drawer on

sliding ebco channel (telescopic).

The shutter of unit having auto hinges lock & "D" ss handle. Unit having ss

legs All inside surface having asian royral paint.

Rate includes 1/2" PVC floor buffer, melamine polish finish, locks, handles,

hardwares etc. complete.

All the beadings and all other inner surface will be polished in shade as

approved.

Manager's Chair (Medium Back) :

Medium back revolving chair with Synchro Mechanism, PP Base, fix crome

handle with PP pad, seat-pu mould, back with 40-45 density u-foam, Gas lift

mechanism with approved tapastry.

Base made from CRCA steel with 5 prolonged and fitted with twin wheel

castors. Size: 1070 mm (H) x 700 (D) x 600(W).

Page 95: Request for Proposals For - Gujarat State PortalRev)22082013.pdfRequest for Proposals For Appointment of Agency for Design, Site Preparation, Supply, Installation and Maintenance of

CSITMS Gujarat Project Confidential

95

9.0 UPS and DG set

9.1 6 KVA UPS

PARAMETER SPECIFICATIONS

Capacity 4200 Watts / 6000 VA

Technology SPWM, IGBT/MOSFET (for more than 72 DC volt IGBT preferred)

Input voltage 230V AC, Single Phase, 3 wire

Input Voltage Range 176V AC to 282V AC

Input Frequency Range 47 /63 Hz +/- 3 Hz (auto sensing)

Input Over Voltage Protection 280V AC

Input Under Voltage Protection 155V AC

Over Voltage cut off Should be offered externally

Output voltage 230V AC Single phase ±1%

Frequency 50 Hz ± 1%

Lead power factor 0.7 Lag to Unity

Output Over Voltage Protection

245V AC Single Phase

Output Under Voltage Protection

210V AC Single Phase

Over load capacity 125% of rated load for 60 sec

Total Harmonic Distortion Less than 3%

Short circuit protection Soft Shut down should occur without blowing any fuse

Crest Factor up to 2 : 1

Over Temperature Indication Required

Load on Battery Indication Required

Battery on Charge Indication Required

Battery low Indication Required

Mains on Indication Required

DC on Indication Required

Page 96: Request for Proposals For - Gujarat State PortalRev)22082013.pdfRequest for Proposals For Appointment of Agency for Design, Site Preparation, Supply, Installation and Maintenance of

CSITMS Gujarat Project Confidential

96

Inverter on Indication Required

Inverter Tripped

1. Output Over Voltage.

2. Output Low

3. Over Load System

Indication Required

Indication Required

Indication Required

Static Switch Automatic Bi-directional should take care of 100% uninterrupted transfer of load from UPS

Transfer Time <4 m sec

Overall Efficiency >85%

Inverter Efficiency >90%

Metering Separate/Single Digital Meter

DC Voltage Display Required

DC Current Charge/discharge Display Required

Output Voltage Display Required

Output Current Display Required

Input Voltage Display Required

Digital three/three & half freq. Meter (for Both input & output)

Display Required

Battery Maintenance-free sealed Lead-Acid battery with suspended electrolyte : leak proof

Period of Backup 1 Hr. with 100% Load

DC Bus Ripple <1%

Total DC Bus Voltage Vendor to specify

No. of Battery Banks Single

No. of Battery Vendor to specify

VAH Rating Vendor to specify

Battery Housing Closed housing with lock

Audible Alarm for Following Conditions

Battery Low Audible alarm Required

Mains Failure Audible alarm Required

Inverter Under-voltage Audible alarm Required

Page 97: Request for Proposals For - Gujarat State PortalRev)22082013.pdfRequest for Proposals For Appointment of Agency for Design, Site Preparation, Supply, Installation and Maintenance of

CSITMS Gujarat Project Confidential

97

Inverter Over Voltage Audible alarm Required

Over Temperature Audible alarm Required

Inverter Overload Audible alarm Required

SNMP Enabled

Environmental

Operating Temperature 0 - 40 °C

Humidity 0 - 95% (non-condensing)

Noise Level <50 dB at full Load from 1 Mtr distance

9.2 DG set

a) DIESEL ENGINE:

Engine should be 6 cylinders, 4 stroke cycle, Water cooled developing desired

KVA at 1500 RPM under NTP conditions of BS: 5514. The engine shall be

provided with electrical starting arrangement & shall give the electrical output of

100 KVA / 80 KW or adequate capacity as per the laod at 0.8 power factor, 415 V

at the alternator terminal. (The preferred make for the diesel engine are

Cummins, Kirloskar, Volvo Penta, Caterpillar and Mitsubishi.)

Governing performance should be in accordance with class-A1 as per ISO-3046, BS-

5514.

Power output guaranteed within 0 to +2 % and can be operated up to 3130 Mt.

altitude and no de-rating for ambient temperature or humidity

Other accessories of the engine should be as under:

b) COOLING SYSTEM

Radiator cooled / HE cooled

Engine mounted Water pump

Thermostats

Corrosion Inhibitor

Self contained piping

Outboard after coolers

Page 98: Request for Proposals For - Gujarat State PortalRev)22082013.pdfRequest for Proposals For Appointment of Agency for Design, Site Preparation, Supply, Installation and Maintenance of

CSITMS Gujarat Project Confidential

98

c) FUEL SYSTEM

PT fuel pump or EUI System

STC Injectors or EUI System

Fuel filters – Paper element type

Self contained piping

d) LUBRICATING SYSTEM

Oil pump

Strainer

Lub oil cooler-Plate type

Oil filter – Paper element type or Spin on Type

Bypass filter ( If required)

Self contained piping

e) AIR INTAKE SYSTEM

Dry type Paper Element filters

Air intake manifold with necessary connections

Turbo charged after cooled

Restriction Indicator

f) EXHAUST SYSTEM

Exhaust manifold

Stainless steel flexible connections suitably optimized to reduce noise.

Silencers (Residential)

g) GOVERNING SYSTEM

Electronic Digital Governor

h) STARTING SYSTEM

Starter, 24V, DC

Battery charging Alternator

With in-built Regulator

i) SAFETY SYSTEM (Engine Protection – Trip)

Low lub oil pressure

Page 99: Request for Proposals For - Gujarat State PortalRev)22082013.pdfRequest for Proposals For Appointment of Agency for Design, Site Preparation, Supply, Installation and Maintenance of

CSITMS Gujarat Project Confidential

99

High water temperature

Over speed

Low Coolant oil level (alarm)

j) OTHER SYSTEM

Flywheel

Flywheel housing

k) POWER COMMAND GENSET CONTROLS

The Power Command Control should be a micro processor based generator set

monitoring, metering, protection and control system. It offers advanced levels of

functions for reliability and optimum Genset performance. An extensive array of

integrated standard control and digital display features eliminate the need for

discrete component devices such as the voltage regulator, governor control and

protective relays. The control system has easy servicing capabilities that allow

system parameters to be interrogated, monitored and adjusted with a PC.

Features:

Digital Governing

Digital voltage regulation

Amp Sentry protection for true alternator O/C protection

Analog/ bargraph/ digital AC output metering

Battery monitoring system to sense and warn against a weak battery

condition

Digital alarm and status message display

Genset monitoring: displays status of all critical engine and generator set

functions

Protection : Over Voltage , Under Voltage ,Over frequency, Under

frequency,

Over current, reverse Power, Load Demand Relay.

Smart starting control system: Integrated fuel ramping to limit black

smoke and frequency overshoot

Advanced serviceability

l) ALTERNATOR:

Page 100: Request for Proposals For - Gujarat State PortalRev)22082013.pdfRequest for Proposals For Appointment of Agency for Design, Site Preparation, Supply, Installation and Maintenance of

CSITMS Gujarat Project Confidential

100

The A. C. Generator shall be 100 KVA or adequate capacity as per the load,

3 phase, 4 wire, 415 V, 0.8 P.F., 1500 RPM, 50 Hz, The preferred make of

the Generator is Stamford.

Salient pole, Brush-less & Revolving field type.

Synchronous, self-excited, self-regulated,

Self- ventilated, Screen Protected Drip Proof,

2/3rd Pitch Winding,

Enclosure: IP23,

Class of Insulation ‘H’

The A.C. Generator shall be Horizontal foot mounted single bearing type

and shall be fitted with Automatic Voltage Regulator (AVR) for Voltage

regulation of +/- 1% or better. The AVR shall be fitted inside the Alternator

terminal box and pre-wired. The A.C. Generator shall meets the

requirements as per IS4722/ BS5000.

m) MOUNTING:

The engine & A.C. Generator described above shall be flexibly coupled,

aligned and mounted on rigid M.S. Fabricated Base Frame.

n) PERIPHERALS:

The DG Set be equipped with all the required peripherals for the smooth

operation of the DG set, few of them are listed below:

Fuel Storage Day Tank Fabricated from MS Sheet Steel and shall be complete

with:

Tube Type Level Indicator

Air vent

Drain Outlet with dead plug

Supply & Return Connection with isolation valves.

o) ACOUSTIC ENCLOSURE:

Acoustic Enclosure with other accessories should meet the detailed

specifications/ scope of supply as under:

Page 101: Request for Proposals For - Gujarat State PortalRev)22082013.pdfRequest for Proposals For Appointment of Agency for Design, Site Preparation, Supply, Installation and Maintenance of

CSITMS Gujarat Project Confidential

101

The noise emission under free field condition shall be 75 dbA at 1mtr.

Distance.

The Acoustic Enclosure should generally comprise / incorporates following:

The Structure / Profile should be made out of export quality CRCA Sheet

Steel.

The roof, side-walls, integral partition and doors should be all sandwich

design made out of export quality CRCA sheet steel.

The Acoustic Enclosure should be natural cooled & maintain ∆ t (Temp.

difference with

Air ambient) of 5 - 7º Cent. If need arises articulated ventilation are also

considered.

The sound absorption material should be selected from either mineral

wool / non-igniting foam of relevant thickness and density to meet the

performance.

The enclosure construction should provide sufficient access for

maintenance work.

The Enclosure should be complete with:

Arrangement for Power Cable connection for supply to load

Suction Louvers

Discharge Louvers

Open able and lockable doors with Air tight neoprene rubber gasket.

Interior lighting arrangement - 1 No. Lamp with ON/OFF Switch on Control

Panel

Lifting arrangements

Page 102: Request for Proposals For - Gujarat State PortalRev)22082013.pdfRequest for Proposals For Appointment of Agency for Design, Site Preparation, Supply, Installation and Maintenance of

CSITMS Gujarat Project Confidential

102

10.0 Firewall / UTM Specifications

Specification

General Requirements:

Should be rack mountable

Must be appliance based and should facilitate multi-application environment.

It should be modular based to accommodate future growth/ expansion

The Firewall should be ICSA Labs for ICSA 4.0 or equivalent certified

The platform should be based on real time, secure embedded operating system

The platform should use ASIC based architecture that is optimized for packet and application level content processing

The proposed system shall support unlimited IP/User license for Firewall / VPN (IPSec & SSL)/ IPS/WCF/AV

Should provide a Http, Https, SSH, Telnet, SNMP based management console for managing and configuring various components of the appliance

Should be IPv6 Ready

Networking & System Performance Requirements:

Should support minimum of 8 no of Gigabit interfaces with 10/100/1000 auto sensing capacity

Should support the standards based Link aggregation technology (IEEE 802.3ad) to achieve higher bandwidth.

Should support IEEE 802.1q VLAN Tagging with about 1024 VLANs supported (in NAT/Route mode)

Should support automatic ISP/link failover as well as ISP/link load sharing for outbound traffic

Should support Dynamic Routing Protocol for RIP1 & 2, OSPF, OSPFv3, BGP4, ISIS, RIPng etc.

Should support Static, Policy Based, and Multicast routing

Should support throughputs of 4.0 Gbps or better for both small & large packets

Page 103: Request for Proposals For - Gujarat State PortalRev)22082013.pdfRequest for Proposals For Appointment of Agency for Design, Site Preparation, Supply, Installation and Maintenance of

CSITMS Gujarat Project Confidential

103

The firewall should support throughput of minimum 1 Gbps of AES - IPSEC VPN and should support H/W acceleration

should support concurrent session minimum 4,00,000

Should support new session per second minimum 15,000

Should support IPS throughput of 600 Mbps or better

Should support GAV throughput of up to 200 Mbps

Should support Site to Site VPN Tunnels up to 1000

Operating System & Management Requirements:

Should prevent inheriting common OS vulnerabilities

Should reside on either on flash disk or hard disk

Allow multiple OS firmware image for booting options

Should be upgradeable via Web UI or TFTP or equivalent mechanism

Should support easy backup or restore via GUI and CLI to/from local PC, remote centralized management or USB disk

Should support profile based login administration for gradual access control like only Policy Configuration, Log Data Access etc.

Should be able to limit remote management access from certain trusted network or host with corresponding administrator account

The proposed system should be able to facilitate administration audits by logging detailed activities to event log for management & configuration updates

The administrator authentication shall be facilitated by local database, PKI & remote services such as Radius, LDAP and TACAS+ with option of 2 Factor Authentication

The Firewall must be capable of clustering multiple firewalls together into a redundant and highly available stateful configuration for creating HA.

Firewall Requirements:

Should support deploy modes like “Stealth Mode” or “Route Mode" or "Transparent Mode” or "Proxy Mode"

Should support integrated Traffic Shaping / QoS functionality

Should support DHCP server & DHCP Agent functionality

Should support Stateful inspection with optional Policy based NAT (Static OR Dynamic)

Should support Inbound Port Forwarding with Load Balancing

Should support IPv6 ACL to implement security Policy for IPv6 traffic

Page 104: Request for Proposals For - Gujarat State PortalRev)22082013.pdfRequest for Proposals For Appointment of Agency for Design, Site Preparation, Supply, Installation and Maintenance of

CSITMS Gujarat Project Confidential

104

All internet based applications should be supported for filtering like Telnet, FTP,SMTP, HTTP, DNS, ICMP, DHCP, RPC,SNMP, BGP, IMAP, NFS etc

Should be able to inspect HTTP and FTP traffic when these are deployed using non standard port( i.e when HTTP is not using standard port TCP/80)

High Availability Requirements:

Must support Active-Active and Active-Passive redundancy.

Must support stateful clustering of multiple active firewalls, and load balance the traffic between them to share the load.

IPSEC VPN Requirements:

The IPSEC VPN and SSL VPN capability shall have ICSA or equivalent Certification

The proposed system shall comply/support industry standards, L2TP, PPTP, IPSEC, and SSL VPN with/without additional external solution, hardware or modules. All such components should be supplied if required externally

Should support hardware VPN acceleration (inbuilt is preferred)

IPSEC (DES, 3DES, AES) encryption/decryption

SSL encryption/decryption

The system shall support the following IPSEC VPN capabilities:

Multi-zone VPN supports

IPSec, ESP security

Supports Aggressive and Dynamic mode

Hardware accelerated encryption using IPSEC, DES, 3DES, AES

Support perfect forward secrecy group 1 and group 2 configuration

MD5 or SHA1/2 authentication and data integrity.

Automatic IKE and Manual key exchange.

Supports NAT traversal

Supports Extended Authentication

Supports Hub and Spoke architecture

DDNS support

Should support IPSEC site-to-site VPN and remote user VPN in transparent mode

SSL VPN Requirements:

Should be integrated solution and should not be user based licensing for SSL VPN

Should support for TWO modes of SSL VPN

1. Web-only mode: for thin remote clients equipped with a web browser only and support web application such as: HTTP/HTTPS PROXY, FTP, SMB/CIFS, SSH, VNC, RDP

Page 105: Request for Proposals For - Gujarat State PortalRev)22082013.pdfRequest for Proposals For Appointment of Agency for Design, Site Preparation, Supply, Installation and Maintenance of

CSITMS Gujarat Project Confidential

105

2. Tunnel mode : for remote computers that run a variety of client and server applications

Network Intrusion Detection & Prevention System Requirements:

The IPS capability shall have ICSA or equivalent NIPS Certification

Should have a built-in Signature and Anomaly based IPS engine

Should be able to prevent DOS & DDOS attacks

Should support Signature based detection using real time updated database

Should support Anomaly based detection that is based on thresholds

Should allow administrators to create Custom IPS signatures

IPS Signatures should be able to update manually or via pull or push technology.

Configurable IPS filters to selectively implement signatures based on severity, target (client/server), protocol, OS and Application types.

Supports automatic security updates directly over the internet without any dependency of any intermediate device

Security check updates should not require reboot of the unit

Supports attack recognition inside IPv6 encapsulated packets

Supports user-defined signatures with Regular Expressions

Supports several prevention techniques including drop-packet, tcp-rst (Client, Server & both) etc. List all prevention options

Antivirus System Requirements

Should be able to block, allow or monitor using AV signatures and file blocking based on per firewall policy

The System should be able to scan Protocols like HTTP, HTTPS, SMTP, SMTPS, POP3, POP3S, IMAP, IM, NNTP etc.

Should be able to allow, block and quarantine attachments or downloads according to file extensions and/or file types

Should support updates of Signatures manually or via pull / push technology.

Should be able to quarantine blocked and infected files to either local hard disk or externally.

Should be able to block or allow oversize file based on configurable thresholds for each protocol types and per firewall policy.

Should be capable scanning Encrypted VPN tunnel traffic originating from the unit for virus

Web & Application Content Filtering System Requirements:

Should have integrated Web Content Filtering solution

Page 106: Request for Proposals For - Gujarat State PortalRev)22082013.pdfRequest for Proposals For Appointment of Agency for Design, Site Preparation, Supply, Installation and Maintenance of

CSITMS Gujarat Project Confidential

106

Should be able to enable or disable Web Filtering per firewall policy or based on firewall authenticated user groups for both HTTP and HTTPS traffic.

Should blocks web plug-ins such as ActiveX, Java Applet, and Cookies

Should support Web Exempt List & blocking of Web URL, score based web keyword

Should be able to replace the web page when the web page matches the Web Filtering blocking criteria.

Should be able to identify, retrieve and rate the actual URL of the cache content commonly available in search engines such as Yahoo and Google

Should be able to identify, retrieve and rate the image/multimedia files from search engines. If belongs to a blocked category, that content should be replaced by a blank.

Should allow administrators to create multiple new local URL filtering categories besides dynamic categories

Should allow administrators to override Online URL Database ratings with local settings

Should have application control feature

Should have the intelligence to identify & control popular IM & P2P applications like KaZaa, BitTorrent etc.

Should have database of minimum 500 types of application awareness

Data Leak Prevention Requirements

Should have the ability to prevent data loss through SMTP, FTP, HTTP, HTTPS & IM

Should have built in pattern database

Page 107: Request for Proposals For - Gujarat State PortalRev)22082013.pdfRequest for Proposals For Appointment of Agency for Design, Site Preparation, Supply, Installation and Maintenance of

CSITMS Gujarat Project Confidential

107

11.0 Antivirus Specifications

Specifications

All the Solutions should be virtualization aware providing flexibility of deploying the

solution both in Virtualization and physical environment.

The antivirus solution should have enhanced protection from Network virus/Worms,

Trojans, Key loggers, Intrusions, Conceivably harmful websites/Phishing sites, Malicious

behavior, data loss, web based threats, root kits, mixed threats, real-time compressed

executable files, spyware/gray ware etc.

Should have Compressed File Detection and Repair and should also be able to reduce the

risk of virus/malware entering the network by blocking files with real-time compressed

executable files.

Should have Unknown Virus Detection & Repair. Should have behavioral & Heuristic

scanning to protect from unknown viruses.

Must be capable of cleaning viruses/malware even without the availability of virus

cleanup components. Using a detected file as basis, it should be able to determine if the

detected file has a corresponding process/service in memory and a registry entry, and

then remove them altogether

Must have the capability to detect and clean Virus and also perform different Scan

Actions based on the virus type (Trojan/ Worm, Joke, Hoax, Virus, other)

Should have buffer overflow protection integrated with AV scan engine for protection

from threats/exploits that uses buffer overflow vulnerability regardless of presence of

signature / OS patches

Should have cloud-client infrastructure with Reputation services like File Reputation,

Web Reputation & Email Reputation working in correlation.

Should have web based management console to give administrators transparent access

to all clients and servers on the network and also provide automatic deployment of

security policies, AV signatures, and software updates on every client and server.

Should support Active Directory integration and also have security compliance to

leverage Microsoft Active Directory services to determine the security status of the

computers in the network and also have logical group based on IP addresses (Subnets).

Establish separate configuration for internally versus externally located machines (Policy

action based on location awareness)

Should have Configurable Scanning. Should have the ability to control the amount of CPU

resources dedicated to a scan process.

Page 108: Request for Proposals For - Gujarat State PortalRev)22082013.pdfRequest for Proposals For Appointment of Agency for Design, Site Preparation, Supply, Installation and Maintenance of

CSITMS Gujarat Project Confidential

108

Must have behavior monitoring to restrict system behavior and malicious changes in

applications, keeping security-related processes always up and running.

Should have device control to regulate the access to external storage devices and

network resources, as well as USB auto run prevention and also provide the granular

level access like No Access, Read Only, Read & write, Full Access etc.

Must provide the flexibility to create firewall rules to filter connections by IP address,

port number, or protocol, and then apply the rules to different groups of users

Must reduce network traffic generated when downloading the latest signature by

downloading only incremental updates of signatures and scan engine.

Reduces network bandwidth consumed during pattern updates. The bulk of pattern

definition updates only need to be delivered to the cloud or some kind of repository and

not to many endpoints

Should be able to update definitions & scan engine on the fly, without a need for reboot

or stopping of services on servers.

Must have the flexibility to roll back the Virus Pattern and Virus Scan Engine if required

via the web console

Should have the capability to assign a client the privilege to act as a update agent for the

update of rest of the agents in the network for AV signatures and hotfix/ service pack/

patch update/upgrade.

Should enable administrators to easily move clients (who have changed departments, for

example) from one physical parent server to another simply by dragging and dropping

through the central management console.

Should have role based administration with active directory integration to add the

custom role type and also use the predefined roles as per requirement.

Should have multiple client deployment options like Web install page, Remote

installation, MSI/EXE package installation, Login Script, Vulnerability Scanner etc.

Should have enhanced tamper protection that guards against unauthorized access and

attacks, protecting users from viruses that attempt to disable security measures.

Should support 32bit and 64bit operating systems

Should have Cache files for scans which can help up to 40% improvement to speed

performance.

Should have a feature of scan cache based on digital signatures or on-demand scan

cache.

It should recognize a missed event on a machine, which was switched off, and restart the

same when machine is turned on.

Should have feedback option so that if any threat (new/earlier) is found, then relevant

data can be automatically collected and transferred to the research team for further

Page 109: Request for Proposals For - Gujarat State PortalRev)22082013.pdfRequest for Proposals For Appointment of Agency for Design, Site Preparation, Supply, Installation and Maintenance of

CSITMS Gujarat Project Confidential

109

analysis to be conducted, and consequently, advanced solutions can evolve and be

provided.

Should have enhanced tamper protection that guards against unauthorized access and

attacks, protecting users from viruses that attempt to disable security measures.

Must support plug-in modules designed to add new security features without having to

redeploy the entire solution, thereby reducing effort and time needed to deploy new

security capabilities to clients and servers across the network

Must have Plug-in solutions - Stateful Inspection Firewall/IPS with Virtual Patching, VDI,

Data Protection, Mac Protection, Mobile Protection without any additional installation

and should provide single console.

Solution should help identify the vulnerabilities and help them fix the same till the time

windows patches are tested in the staging environment and apply the same.

Solution should be able to Shields endpoints against unwanted network traffic with

multiple protection layers

Solution should be able to Blocks known and unknown vulnerability exploits before

patches are deployed

Solution should be able to Automatically adjusts security configuration based on the

location of an endpoint and removes / block the bad traffic from Business-Critical Traffic

Should Block attacks before they enter the endpoint’s application and execution layer

Solution should have application control filters to alert/

block specific traffic such as instant messaging and media streaming, etc..

Should have deep packet inspection to identify content that may harm the application

layer.

Solution should Provides protection before patches are

deployed using attack blocking and vulnerability shielding

Should Block all known exploits with attack-facing network inspection

Solution be able to Defend custom and legacy applications

using custom filters that block user-defined parameters

Solution mush reduce the deployment cycle by eliminating

the need to redeploy the entire solution

Solution should provide recommendation to the administrator by identifying the

vulnerability of the operating systems and the applications installed and also help

automate the process of enforcing the rules to patch / block this vulnerabilities.

Solution should have plug-in architecture for instant, live deployment to previously

installed antivirus clients, thus providing HIPS protection via single integrated

management console.

Page 110: Request for Proposals For - Gujarat State PortalRev)22082013.pdfRequest for Proposals For Appointment of Agency for Design, Site Preparation, Supply, Installation and Maintenance of

CSITMS Gujarat Project Confidential

110

Should provide Data Loss Protection as an plug-in solution with the capability of data

protection with multichannel monitoring, robust rules, and predefined policy templates.

Data Protection must have File Attribute, Key words and Pattern based technology in

single solution.

Data Protection should work in both environment - Workgroup and AD with User/

Group/ Domain based policy creation option.

Solution should support Mobile Security Solution as a Plug in Module and should be

managed from same Anti Virus Server.

Virtual Desktop Support : Solution should support Virtual Desktop integrated in the single

antivirus console as a module for the following platforms:

· VMware vCenter™ 3.5 and 4 (VMware View™ 4)

· Citrix™ XenServer™5.5 and 5.6 (Citrix XenDesktop™ 4)

Mobile Security Specifications

Solution should protect the wide range of consumer-grade mobile devices, such as

iPhones, iPads, Android, and Blackberry devices.

Solution should be Centralized, Integrated, Scalable, with Single Console Management

for all managing Desktop, Laptops and Mobile devices using one console.

Solution should permit feature lock to disable camera, Bluetooth®, and SD card reader

Solution should provide multi cross-device policies for consistent application and

enforcement of security and management requirements

Solution should provide feature to define online and offline policies

Solution should provide anti-malware protection which has industry-leading, cloud-

based threat intelligence which will help protect the devices with the latest threats.

Should be able to detects and block malicious applications and data files

Solution should be able to protect against malicious websites and malious content.

Should have features like Firewall / IDS which will help detect attacks on the device via

network applications, ports etc…

Solution should be able to monitor, block and logs the calls, sms, mms messages sent to

and from devices, based on the user policy.

Page 111: Request for Proposals For - Gujarat State PortalRev)22082013.pdfRequest for Proposals For Appointment of Agency for Design, Site Preparation, Supply, Installation and Maintenance of

CSITMS Gujarat Project Confidential

111

Solution should provide seamless cross-platform security regardless of device factor:

▪▪ iOS (iPad and iPhone)

▪▪ Android™

▪▪ Windows®

▪▪ Symbian

▪▪ RIM Blackberry

(Note: Capabilities may vary by platform.)

Solution should provide Expanded mobile device management capabilities which will

help organizations to remotely provision and de-provision and secure both company and

employee-owned smart phones and tablets

Solution should provides critical visibility into devices and status, including encryption

and password configuration.

Solution should have features like Remote lock, remote wipe, and power-on-password

enforcement which will help organization to protect corporate data on smart phones

and tablets in case of loss or theft

Solution should provide device inventory and location tracking feature which will help

trace the device in case of theft or loss

Should provide Encryption providing organizations to comply with Encryption

requirement with multi-level encryption algorithm option:

• AES 128-bit

• AES 192-bit

• AES 256-bit

• AES+XTS

Should be able to integrate with Active Directory

Solution should have Web Reputation filters to protect your mobile device from unsafe

Web sites

Solution should have features like SMS Anti-spam which will ensure only genuine SMS

are received by the end-user

Should be capable to protect the end-users from WAP-Push Messages which are used to

deliver unwanted applications, content, system settings and even malware

Solution should be able to log all the details for e.g. virus/malware, firewall, SMS anti-

spam logs, task logs, system logs etc….

Solution should have feature of remote device unlock feature from the central

management server which will help administrator if a user has forgotten the power-on

password.

Page 112: Request for Proposals For - Gujarat State PortalRev)22082013.pdfRequest for Proposals For Appointment of Agency for Design, Site Preparation, Supply, Installation and Maintenance of

CSITMS Gujarat Project Confidential

112

Solution should have feature to send update settings to mobile devices which will help

mobile device to auto-check components, configuration and policy changes.

Solution should have mobile agent capable of doing real-time scan feature.

Should have feature to scan memory card when a memory cared is inserted in the

mobile device

Should have Scan Actions like remove the infected file, Quarantine the infected file, send

logs to the Mobile security server when connected

Should be able to scan compressed files like ZIP, CAB

Should have option to specify the number of compression layers to scan

Should have feature to enable or disable call filtering for mobile device, configure mobile

device to use allowed or block list, configure filtering list from the management console,

administrator should have control to allow, block , modify the list defined

Should have features enables you to control the applications that users can run on their

mobile devices.

LINUX PROTECTION

Solution should help maintain corporate antivirus policies that extend critical protection

to Linux servers.

Solution should offer comprehensive real-time protection for enterprise web-servers

and file-servers, preventing them from spreading malware to internal or external

endpoints.

Solution should be designed to protect Linux servers from inadvertently hosting viruses,

Trojan horses, bots, and other malware

The solution should be stable and reliable and should have certifications from all major

Linux vendors, including Redhat™, Novell™, IBM™, and Virus Bulletin.

Solution should have Central Management and should be able Seamlessly integrate with

single management console framework which enables central management of attack

information, policy deployment, pattern file and scan engine deployment, and reports

on policy implementation

Solution should be easy to install with an ability of web-based interface supports

multiple simultaneous remote installations as well as central update and configuration

that accelerate the rollout process on the broadest range of Linux distributions.

Solution should have Real-time, on-demand, and scheduled scanning uses the latest

multi-threaded scanning engine for highest performance and kernel-level scanning to

help minimize performance degradation.

Page 113: Request for Proposals For - Gujarat State PortalRev)22082013.pdfRequest for Proposals For Appointment of Agency for Design, Site Preparation, Supply, Installation and Maintenance of

CSITMS Gujarat Project Confidential

113

Solution should prevent suspect files from reaching end users by notifying the

administrator. It should also block infected files from re-entering the system, defending

the network from possible re-infection.

Solution must ensure Linux servers comply with corporate antivirus policies.

Solution should support secure socket layer (SSL) protocol to maximize protection of

data transfer during remote management administration

Solution should enable antivirus policy enforcement and accelerates update deployment

through automatic updates of virus patterns and scan engines

Solution should allow administrators to create alert of virus or program events through

email notifications and SNMP traps

Solution should be powered by solution vendor’s global network of research centers

committed to constant threat surveillance and attack prevention. By continuously

monitoring the Internet and customer networks, solution vendor should have security

specialists develop both Internet and customer-specific threat intelligence. With

accurate, real-time data, solution vendor should deliver more effective, timely security

measures designed to detect, pre-empt, and eliminate attacks.

Solution should prevent Linux servers from spreading threats to other servers and

personal computers.

Solution should have facility of Remote Management through a Web Browser, which will

help configure the solution via a browser-based console. It should also allow you to

control the application from any location.

Solution should be compatible with a browser-based console like MicrosoftTM Internet

Explorer™, Mozilla™, or Mozilla

Firefox.

Solution should have Manual, Real-Time, and Scheduled Scanning options.

In addition to manual scanning option solution should act against viruses/malwares

automatically without user intervention. Whenever user access a file, Real-time Scan

should check that file for viruses/malwares (for example, when you copy or open a file).

Scheduled scanning should thoroughly scan Linux machine or the specified directories at

regular, user-specified intervals. Should provide an option to schedule scans after office

hours to avoid interfering with normal operations.

Real-time option should also detect viruses/malwares in Linux applications whenever an

application is executed.

Solution should back up infected files before the Real-time Scan, Manual Scan, or

Scheduled Scan features and perform the Clean action.

Page 114: Request for Proposals For - Gujarat State PortalRev)22082013.pdfRequest for Proposals For Appointment of Agency for Design, Site Preparation, Supply, Installation and Maintenance of

CSITMS Gujarat Project Confidential

114

Solution should provide option to Manually and Automated Log Deletion.

Solution should provide option to perform manual or scheduled virus pattern and scan

engine file updates to ensure up-to-date virus protection. Solution should also give

option to specify your Internet-based update server.

Solution should provide an option to configure Simple Network Management Protocol

(SNMP) settings for email notifications about events, such as virus/malware outbreaks,

that occur on machines running vendor’s solution client.

In addition to providing a Web-based management console, solution should provide

command-line support for the following: real-time scans, scheduled scans, manual scans,

log deletions, and virus pattern/engine updates.

Solution should be with the latest technology of scanning the files, in addition to Scan All

or Scan by File Name Extension, the latest technology should optimize security by

examining file headers using true file type recognition, and scanning file types known to

potentially harbor malicious code.

Solution should have experts action defined for dealing with virus, worms, Trojans, etc….

Solution should have is a new method of selecting the action to take when a security risk

has been detected, also solution vendor should customize scan actions for different

types of security risks. New scan actions should be updated when you download

updates.

Central Management

Solution should have single console to Manage desktop AV , Servers , Mail and Web

Gateway software solution

Should be a Software Solution Integrated, centrally-managed security framework—for a

unified defense

Simplifies administration with automated update deployment and license renewal

Provides single sign-on, eliminating the need to logon to each product

Consolidates data for a master view of Central Manager servers throughout the

network

Simplifies administration with a web based console and integrated agent

should have capability for consolidating updates and global alerts

Should have Intelligence with customizable, flexible reports for easy interpretation

Expands visibility into individual clients, reducing desk-side visits

Software should Ensures only authorized personnel make critical changes to the

security environment

Assigns specific privileges based on predefined administrative roles

Allows user-defined customizable administrative roles

Page 115: Request for Proposals For - Gujarat State PortalRev)22082013.pdfRequest for Proposals For Appointment of Agency for Design, Site Preparation, Supply, Installation and Maintenance of

CSITMS Gujarat Project Confidential

115

Supports visibility into clients so central IT can remotely monitor and manage client

security

Should have capability to implement Parent-->Child Architecture

Solution should support Role based administration

Should have capability to control the Outbreak scenario such as applying/ removing

policy related to outbreak as when required.

Should have capability to provide critical alerts during virus outbreak, action taken on

infections, suspicious vulnerability detection

Should be able to produce the reports on scheduled and one-time basis and shall also

be able to automatically deliver reports via email to designated users

Reports shall support the following formats: PDF, RTF, ActiveX, Crystal Reports

Should have Report Templates minimum as per below:

Virus & Spyware/Grayware Detection Reports

Antivirus Client Information Reports

Antivirus Product Registration Report (Registration Status)

Comparative Reports

Antivirus Server Deployment Reports

Virus Damage Cleanup Services Reports

Top 10 Virus and Infected Files Detection Report

All Entities Virus Infection List

Top 10 Infected Email Sender Report

Daily Virus Count

Top 10 Virus & Security Violation Report

Virus Infection Channel vs.Product

Web Security Violations Report

Desktop Antivirus Protection Summary

Filter Events by Frequency Report

Filter Events by Policy Report

Spam Summary for Recipients Report

Spam Summary for Domains

Outdated Antivirus Client

Consolidated Report

Page 116: Request for Proposals For - Gujarat State PortalRev)22082013.pdfRequest for Proposals For Appointment of Agency for Design, Site Preparation, Supply, Installation and Maintenance of

CSITMS Gujarat Project Confidential

116

12.0 NMS Specifications

Network Discovery

GUI based system (Web based & Windows Based)

Auto - discovery on Physical and logical basis

Discovery of network elements should be on per device basis and automatically group by

vendor

Should support the discovery of devices from Layer -2 to Layer -3 devices

Captures logical connectivity information including virtual private network (VPN), virtual

local area network (VLAN)

built-in wireless monitoring should supports both autonomous access points and

controller-based technology

Fault Management

Support comprehensive fault management for all the network devices

Should give event details & track root cause by launching fault summary

Quickly identify the source of network faults and speed problem resolution with real-

time root-cause analysis

Support diagnostic function for multicast & unicast

Monitor & troubleshoot problems at the protocol

Performance Management

System should give real time utilization and performance matrix

Give the facility to track the performance matrix subnet basis, VLAN basis and protocol

basis

Support wireless LAN Management

Support specific protocol level performance characteristics

Delivers highly accurate, real-time information on network connectivity, availability,

performance, usage, and inventory

Define parent and child dependencies so that a child object will appear ‘unreachable’

instead of ‘down’ if the parent is down

Prevent a network outage from sending redundant alerts by recognizing the critical

parent device outage

Monitors, tracks the up/down status, and analyzes real-time, in-depth, network

performance statistics for routers, switches, wireless access points, servers, and any

other SNMP-enabled device.

Device-by-device drill down and detailed system information on network devices,

servers, virtual machines, or virtual or Fibre Channel switches.

Page 117: Request for Proposals For - Gujarat State PortalRev)22082013.pdfRequest for Proposals For Appointment of Agency for Design, Site Preparation, Supply, Installation and Maintenance of

CSITMS Gujarat Project Confidential

117

Security Management

Support network Integrity and security with a user based network security model via full

SNMP V-3 support

Authentication & privacy keys on per user basis

Multiple users on per IP address basis

Inventory Management

Should support inventory management on per device basis

Module level inventory management support

Should be able handle Alert/Event management

Should be able to monitor the server system usage

Should support workflows for improved setup and troubleshooting

Should offer centralized change -audit logging, graphical device management

Should provide network response and availability information for WAN networks

Should support Portal technology which allows the user to customize views into the

network management application functionality or chose from one of the three default

views provided

Should support a wide collection of switch-and-router analysis tools is accessible from a

single location; third -party applications can link to the tools centre

Traffic Analyzer

Comprehensive, customizable view of network traffic on a single page.

Drill down into any element’s traffic using multiple views

Create and access personalized network traffic views by filtering NetFlow, J-Flow, sFlow®,

IPFIX, and CBQoS data based on specific parameters, such as date or location

Advanced Application Mapping- Monitor network traffic from multi-port applications,

Gain insight into top application hogs by organizing traffic coming from common

applications such as Apple® QuickTime, Oracle® databases, and telnet

traffic analysis on turbo boost by focusing on top talker bandwidth usage

Delivers an instant alert notification, including a list of “top talkers”, when an interface

exceeds its utilization threshold

View network traffic segmented by Class of Service methods, measure effectiveness of

your CBQoS policies, and quantify bandwidth consumption by class map

Analyze network traffic with custom overlapping IP address groups

Analyze NetFlow, J-Flow, sFlow, and IPFIX data on devices from Cisco Systems®, Extreme

Networks®, HP®, Juniper®, Nortel Networks®, and other leading vendors

Create in-depth network traffic reports with a few clicks or schedule automatic weekly

delivery

Page 118: Request for Proposals For - Gujarat State PortalRev)22082013.pdfRequest for Proposals For Appointment of Agency for Design, Site Preparation, Supply, Installation and Maintenance of

CSITMS Gujarat Project Confidential

118

13.0 Multifunctional Printer

Printing Technology: Laser Monocrom

Format: A4

Printing Speed: A4 / Letter – minimum 40 ppm

Printing Resolution (dpi): 600 x 600 dpi (1200 x 1200dpi equivalent)

First Page (sec): A4 / Letter - 8.6 sec

Memory (MB): Minimum 512MB

Paper Feeding: 600 (Standard – 500 + Multipurpose Tray – 100)

Interface: USB 2.0

Network: 10Base-T / 100Base-TX / 1000Base-T

Duplex: Standard (only A4 / LTR / LGL / 8.5"×13")

Size (W x D x H mm): 454 x 424 x 345 mm

Power Printing (W): Approx 660 W

Others: 5 Line LCD Operation Panel

Power Stand-by (W): 15 W

Noise Level 54.5 dB or less

Maxim Volume (page): 100000 pages

Page 119: Request for Proposals For - Gujarat State PortalRev)22082013.pdfRequest for Proposals For Appointment of Agency for Design, Site Preparation, Supply, Installation and Maintenance of

CSITMS Gujarat Project Confidential

119

Annexure – I Approved Make

Product Approved Makes

Fixed IP Outdoor Camera Sony, Axis, Bosch, Pelco, Infinova

IP PTZ Camera Sony, Axis, Bosch, Pelco, Infinova

Outdoor IP 55 enclosure with Air

conditioner / Outdoor Cooling Unit Rittal, WQ

Network Switch Cisco, Juniper, HP-3com, Avaya-Nortel,

Brocade

Bandwidth Tata, Reliance, BSNL, Airtel, Tulip, Sify

Storage HP, IBM, Dell, EMC, Net App, Hitachi

Video Management Software Milestone, DVTel, Nice

Automatic Number Plate Recognition

System, Challaning System Kritikal, Eng Techno

Red Light Violation Detection System Kritikal, Eng Techno

Manual Challan Kritikal, Eng Techno

Air Conditioner Voltas, Blue star, Hitachi, Daikin, o’general

UPS APC, Emerson, EATON

DG Set Kirloskar, Cummins, Volvo penta

Access Control System Honeywell, Siemens

Fire detection and Suppression Honeywell, Siemens, Notifier

Internal CCTV system for Datacenter Sony, Axis, Bosch, Pelco, Infinova

Server / Workstation HP, Dell, IBM

USB Joystick Sony, Axis, Bosch, Pelco, Infinova or

Equivalent make

Video Wall Samsung , Planar, Sharp, Barco, Sony, Delta

Furniture Godrej, Featherlite, Wipro

Page 120: Request for Proposals For - Gujarat State PortalRev)22082013.pdfRequest for Proposals For Appointment of Agency for Design, Site Preparation, Supply, Installation and Maintenance of

CSITMS Gujarat Project Confidential

120

Firewall / UTM Checkpoint, Juniper, Fortinet

Antivirus Mcafee, Symantec, Trend Micro

Network Management Software HP, IBM, Solarwind, CA, Manage Engine

Multifunctional Printer HP, Canon, Samsung