research infrastructure of full scale experimental ... · kict research infrastructure of full...
TRANSCRIPT
KICT
Research Infrastructure of Full Scale Experimental Substantiation
River Experiment Center
Korea Institute of Construction TechnologyKorea Institute of Construction Technology
KICT
CONTENTS CONTENTS CONTENTS CONTENTS CONTENTS CONTENTS CONTENTS CONTENTS
Outline Outline Outline Outline Outline Outline Outline Outline Outline Outline Outline Outline
ⅡⅡⅡⅡⅡⅡⅡⅡ Supporting Facilities Supporting Facilities Supporting Facilities Supporting Facilities Supporting Facilities Supporting Facilities Supporting Facilities Supporting Facilities Supporting Facilities Supporting Facilities Supporting Facilities Supporting Facilities
ⅢⅢⅢⅢⅢⅢⅢⅢ Experiment FacilitiesExperiment FacilitiesExperiment FacilitiesExperiment FacilitiesExperiment FacilitiesExperiment FacilitiesExperiment FacilitiesExperiment FacilitiesExperiment FacilitiesExperiment FacilitiesExperiment FacilitiesExperiment Facilities
ⅠⅠⅠⅠⅠⅠⅠⅠ
ⅣⅣⅣⅣⅣⅣⅣⅣ Closing RemarksClosing RemarksClosing RemarksClosing RemarksClosing RemarksClosing RemarksClosing RemarksClosing RemarksClosing RemarksClosing RemarksClosing RemarksClosing Remarks
KICT
ⅠⅠⅠⅠⅠⅠⅠⅠ
Back-
ground
� Lack of experiment facilities capable of conducting full scale tests of river hydraulics and ecology
• Researchers and technicians• Facilities• Climate change• River restoration
Goals
� Full scale experimentation• Hydraulic and ecological experiments in full scale• Simulation of prototype river conditions
- Physical factors: flow rate, geomorphology, sediments, geometry, …- Ecological species: vegetation, fishes, invertebrate, ...- River environments: floods, water quality, …
� Quantitative investigation of natural prototype river conditions
OutlineOutlineOutlineOutlineOutlineOutlineOutlineOutlineOutlineOutlineOutlineOutline
1. Background & Goals
KICT
ⅠⅠⅠⅠⅠⅠⅠⅠ
2005.12Approval of establishment of Korean type multipurpose river experiment center (National Assembly Consideration, $ 12M)
2006.11Agreement of Korean type multipurpose river experiment center (Kyeongsangbuk-Do, Andong-Si, KICT)
2006.12 Working design for the center (Dongbu Eng.)
2007.12 Construction and supervision order of the center (Cheonggu Const., Dongbu Eng.)
2008.04 Groundbreaking ceremony of the center
2009.12 Construction completion & renamed as the River General Experiment Center
2011.09 Opening of Pungnam Bridge over the Nadong River
2011.09 Renamed as the River Experiment Center of the River & Coastal Research Division
2012.12 Official opening of the River Experiment Center
2013.01 Opening of the guest house( 館館館館) for business and academic cooperation
OutlineOutlineOutlineOutlineOutlineOutlineOutlineOutlineOutlineOutlineOutlineOutline
2. History of the River Experiment Center
2009200920092009
2011201120112011
2012201220122012
KICT
ⅠⅠⅠⅠⅠⅠⅠⅠ OutlineOutlineOutlineOutlineOutlineOutlineOutlineOutlineOutlineOutlineOutlineOutline
3. Views (2009.10 ~ 2013.05)
Oct. 2009 Jun. 2012
Dec. 2012 May. 2013
KICT
2012. 6
Total area : 193,051 m2
Supporting Facilities: Research building, Guest house, Electronic room & Pump station
- large capacity pumps (max. flow rate of 10 m3/s),Experiment Facilities: three proto-type channels (560~680 m long, 11 m wide),
a concrete flume (50 m long, 2 m wide, 1.4 m Height), two artificial pond
4. Facilities of KICT-REC
OutlineOutlineOutlineOutlineOutlineOutlineOutlineOutlineOutlineOutlineOutlineOutlineⅠⅠⅠⅠⅠⅠⅠⅠ
KICT
ⅡⅡⅡⅡⅡⅡⅡⅡ취수탑
Supply flow from the intake to the inflow tank and the head tank with large capacity pumps
Electronic Room & Pump Station Inflow Tank
Research BuildingGuest House
Store flow discharged to the channels, temporarily
Consist of analysis & control labs, meeting room, seminar room, and conference hall
Dormitory facilities for cooperating researchers’ convenience
Supporting FacilitiesSupporting FacilitiesSupporting FacilitiesSupporting FacilitiesSupporting FacilitiesSupporting FacilitiesSupporting FacilitiesSupporting FacilitiesSupporting FacilitiesSupporting FacilitiesSupporting FacilitiesSupporting Facilities
1. Main Facilities
175kW 2ea, 490kW 1ea,
310kW 1ea (Total 10.0 m3/s)
Gates
Water level control of each channel
KICT
2. Research Building
현위치
현위치
현위치
현위치
MeetingMeetingMeetingMeetingRoomRoomRoomRoom
DirectorDirectorDirectorDirectorTechnicalTechnicalTechnicalTechnicalAssistanceAssistanceAssistanceAssistance
Laboratory Laboratory Laboratory Laboratory ⅡⅡⅡⅡ Laboratory Laboratory Laboratory Laboratory ⅠⅠⅠⅠ
Visiting Lab.Visiting Lab.Visiting Lab.Visiting Lab.
AdministrationAdministrationAdministrationAdministrationOfficeOfficeOfficeOffice
ToiletToiletToiletToilet
Conference HallConference HallConference HallConference Hall
SeminarSeminarSeminarSeminarRoomRoomRoomRoom
ControlControlControlControlRoomRoomRoomRoom
MachineryMachineryMachineryMachineryRoomRoomRoomRoom
EntranceEntranceEntranceEntrance
GeneratorGeneratorGeneratorGeneratorRoomRoomRoomRoom
ReceptionReceptionReceptionReceptionRoomRoomRoomRoom
LaboratoryLaboratoryLaboratoryLaboratoryⅢⅢⅢⅢ
KRRNKRRNKRRNKRRNSecretariatSecretariatSecretariatSecretariat
LoungeLoungeLoungeLounge
RobbyRobbyRobbyRobby
Meeting Room (20~25)Meeting Room (20~25)Meeting Room (20~25)Meeting Room (20~25) Conference Hall (120)Conference Hall (120)Conference Hall (120)Conference Hall (120) Seminar Room (60~70)Seminar Room (60~70)Seminar Room (60~70)Seminar Room (60~70) Visiting Lab. (12~15)Visiting Lab. (12~15)Visiting Lab. (12~15)Visiting Lab. (12~15)
ⅡⅡⅡⅡⅡⅡⅡⅡ Supporting FacilitiesSupporting FacilitiesSupporting FacilitiesSupporting FacilitiesSupporting FacilitiesSupporting FacilitiesSupporting FacilitiesSupporting FacilitiesSupporting FacilitiesSupporting FacilitiesSupporting FacilitiesSupporting Facilities
KICT
Nakdong River
Research Building
Guest House
RetentionPond
Concrete Flume& Water Tank
Large Weir Model
Steep-slope Channel (A1)Steep-slope Channel (A1)
Straight Channel (A2)Straight Channel (A2)
Meandering Channel (A3)Meandering Channel (A3)
1. Layout Sketch of Experiment Facilities
ⅢⅢⅢⅢⅢⅢⅢⅢ Experiment FacilitiesExperiment FacilitiesExperiment FacilitiesExperiment FacilitiesExperiment FacilitiesExperiment FacilitiesExperiment FacilitiesExperiment FacilitiesExperiment FacilitiesExperiment FacilitiesExperiment FacilitiesExperiment Facilities
KICT
• Channel type: Steep sloped
• Total length: 590 m• Test section: 520 m
• Main experiments- Revetment test - Roughness test
(vegetation, bed)- Structure stability
• Cross section
Inflow Outflow
Flow
stabilization
Revetment stability
test region
Flow resistance
test region
Structure stability
test region
ⅠⅠⅠⅠ ⅡⅡⅡⅡ ⅢⅢⅢⅢ ⅣⅣⅣⅣ
� revetment stability and flow resistance
Slope : 1/70 Slope : 1/1000
3 m
1: 2 slope1: 2
slope
11 m
2. Steep slope channel (A1)
ⅢⅢⅢⅢⅢⅢⅢⅢ Experiment FacilitiesExperiment FacilitiesExperiment FacilitiesExperiment FacilitiesExperiment FacilitiesExperiment FacilitiesExperiment FacilitiesExperiment FacilitiesExperiment FacilitiesExperiment FacilitiesExperiment FacilitiesExperiment Facilities
KICT
Revetment stability test
Flow resistance test (pussy willow)
Inflow Outflow
Flow
stabilization
Revetment stability
test region
Flow resistance
test regionStructure stability
test region
ⅠⅠⅠⅠ ⅡⅡⅡⅡ ⅢⅢⅢⅢ ⅣⅣⅣⅣ1 2
3 4
32 41
ⅢⅢⅢⅢⅢⅢⅢⅢ Experiment FacilitiesExperiment FacilitiesExperiment FacilitiesExperiment FacilitiesExperiment FacilitiesExperiment FacilitiesExperiment FacilitiesExperiment FacilitiesExperiment FacilitiesExperiment FacilitiesExperiment FacilitiesExperiment Facilities
Bridge pier failure test
KICT
취수탑
InflowOutflow
Hydraulic structures
test region (1)
ⅠⅠⅠⅠ ⅡⅡⅡⅡ ⅢⅢⅢⅢ
� hydraulic structures and river restoration
Hydraulic structures
test region (2)
Wetlands and flood plain
test region (2)
• Channel type: Straight channel
• Total length: 560 m
• Test section: 470 m
• Main experiments- River crossing structures
and ecological effects - Wetlands and flood plain
• Test region
3. Straight channel (A2)
Slope : 1/800
• Cross section
A
A’
C
C’
3 m
1: 21: 2
11 m
A-A’ section C-C’ section
1 m
1: 2
16 m
1: 2 1: 2
6.5 m
ⅢⅢⅢⅢⅢⅢⅢⅢ Experiment FacilitiesExperiment FacilitiesExperiment FacilitiesExperiment FacilitiesExperiment FacilitiesExperiment FacilitiesExperiment FacilitiesExperiment FacilitiesExperiment FacilitiesExperiment FacilitiesExperiment FacilitiesExperiment Facilities
KICT
InflowOutflow
Hydraulic structures
test region (1)
ⅠⅠⅠⅠ ⅡⅡⅡⅡ ⅢⅢⅢⅢ
Hydraulic structures
test region (2)
Wetlands and flood plain
test region (2)
River crossing structures: ecofriendly low head structures
1 2 3 4
4321
ⅢⅢⅢⅢⅢⅢⅢⅢ Experiment FacilitiesExperiment FacilitiesExperiment FacilitiesExperiment FacilitiesExperiment FacilitiesExperiment FacilitiesExperiment FacilitiesExperiment FacilitiesExperiment FacilitiesExperiment FacilitiesExperiment FacilitiesExperiment Facilities
KICT
Flow
stabilization
Inflow Outflow
Sinuosity
(1.2)
ⅠⅠⅠⅠ
ⅡⅡⅡⅡ
ⅢⅢⅢⅢ
Meandering test region
ⅣⅣⅣⅣ
� meandering process and flooding
Flow
stabilization
Flooding
test region
• Channel type: Meandering
• Total length: 680 m
• Test section: 620 m
• Main experiments- Meandering process - Flood frequency- Ecological monitoring
Sinuosity
(1.0)
Sinuosity
(1.5)
Sinuosity
(1.7)
Sinuosity
(1.0)
4. Meandering channel (A3)
Slope : 1/800
• Cross section
3 m
1: 2 slope1: 2
slope
11 m
1 m
1: 2
11 m
1: 2
1: 2
1: 2 1 m
B
B’
A
A’
A-A’ section B-B’ section
ⅢⅢⅢⅢⅢⅢⅢⅢ Experiment FacilitiesExperiment FacilitiesExperiment FacilitiesExperiment FacilitiesExperiment FacilitiesExperiment FacilitiesExperiment FacilitiesExperiment FacilitiesExperiment FacilitiesExperiment FacilitiesExperiment FacilitiesExperiment Facilities
KICT
Fish Screen MonitoringGPS Floater test
Flow
stabilization
Inflow Outflow
Sinuosity
(1.2)
ⅠⅠⅠⅠ
ⅡⅡⅡⅡ
ⅢⅢⅢⅢ
Meandering test region
ⅣⅣⅣⅣ
Flow
stabilization
Flooding
test regionSinuosity
(1.5)
Sinuosity
(1.7)
32
4
1 4
321
ⅢⅢⅢⅢⅢⅢⅢⅢ Experiment FacilitiesExperiment FacilitiesExperiment FacilitiesExperiment FacilitiesExperiment FacilitiesExperiment FacilitiesExperiment FacilitiesExperiment FacilitiesExperiment FacilitiesExperiment FacilitiesExperiment FacilitiesExperiment Facilities
Test of the Debris Effecton the Bridge Pier
KICT
5. Concrete Flume
ⅢⅢⅢⅢⅢⅢⅢⅢ Experiment FacilitiesExperiment FacilitiesExperiment FacilitiesExperiment FacilitiesExperiment FacilitiesExperiment FacilitiesExperiment FacilitiesExperiment FacilitiesExperiment FacilitiesExperiment FacilitiesExperiment FacilitiesExperiment Facilities
Fish Screen Set (bubble, light, sound)
Test of Reaction to soundTest of Reaction to lightTest of Reaction to bubble
KICT
� Area: 17,523 m2
� Retention storage: 14,862 m3
� Main experiments:
- Ecological environment test in the retention pond
- Lake retention test
취수탑
� Area: 1,203 m2
� Flow rate: Max. of 0.15 m3/s
� Main experiments:
- Aquatic plant purification
- Organism habitat tests
� Retention Pond � Multi-purpose Pond
6. Artificial Pond
ⅢⅢⅢⅢⅢⅢⅢⅢ Experiment FacilitiesExperiment FacilitiesExperiment FacilitiesExperiment FacilitiesExperiment FacilitiesExperiment FacilitiesExperiment FacilitiesExperiment FacilitiesExperiment FacilitiesExperiment FacilitiesExperiment FacilitiesExperiment Facilities
KICT
Ultrasonic wave meter, Pressure type sensor, …
Water level measurements
Flow velocitymeasurements
1D velocity meter (propeller type, price-cup type),
3D Micro-ADV, …
River bed measurements
3D scanner (range: max. of 400 m; accuracy of ±3 mm),
RTK GPS, Total Station, Laser Level, …
Weather Station, Drag force
meter, …
Others
7. Measurement Equipment
ⅢⅢⅢⅢⅢⅢⅢⅢ Experiment FacilitiesExperiment FacilitiesExperiment FacilitiesExperiment FacilitiesExperiment FacilitiesExperiment FacilitiesExperiment FacilitiesExperiment FacilitiesExperiment FacilitiesExperiment FacilitiesExperiment FacilitiesExperiment Facilities
KICT
The Future of the KICT-REC
ⅣⅣⅣⅣⅣⅣⅣⅣ Closing RemarksClosing RemarksClosing RemarksClosing RemarksClosing RemarksClosing RemarksClosing RemarksClosing RemarksClosing RemarksClosing RemarksClosing RemarksClosing Remarks
� Making a role in the world as a global experiment center
� Making the KICT-REC be a place where any researchers focused river experiments in the world can voluntarily come, conduct research and discuss in there
For the CHy Project on the Assessment of the Performance of Flow Measurements and Techniques
� Providing a variety of test site and condition for this project
� Carrying out some parts of tests in this project.
� Making a role to establish and spread of international Standard
KICT
Thank youThank youThank youThank youThank youThank youThank youThank youThank youThank youThank youThank you
KICT
ⅡⅡⅡⅡⅡⅡⅡⅡ취수탑
Steep-slope Channel (A1)Steep-slope Channel (A1)
Straight Channel (A2)Straight Channel (A2)
Meandering Channel (A3)Meandering Channel (A3)
Retention PondRetention Pond
Research BuildingResearch Building
Outflow PondOutflow Pond
Security CheckpointSecurity Checkpoint
Pumping StationPumping Station
Inflow TankInflow Tank
Multi-purpose Lake Research StationMulti-purpose Lake Research Station
KICT RECKICT RECKICT RECKICT RECKICT RECKICT RECKICT RECKICT RECKICT RECKICT RECKICT RECKICT REC