Design a TS4
Residential Design with TS4 ModularitySelective deploymentPredictive IV (PIV)
Lowest cost Greatest ROI
Click to continueTS4 currently offers 5 different functionalities
OptimizationTS4-O
MonitoringTS4-M
Long StringsTS4-L
DiodesTS4-D
Safety - RSSTS4-SThis guide is going to take you through a short introduction, different use cases, and how to select the best configuration for your project
Residential Design Guide with TS4NavigationAt any given point you can go back to the previous slide, or start over, by clicking on one of the action buttons:Back to previous slideStart overClick to continue
Modularity and Selective DeploymentStep 1: Select the Basic Functionality that Addresses your Needsx 4 x 6
kW
TS4-MTS4-O x 2Step 2: Identify shaded areas and optimize utilizing PIVClick to continueWithout optimization, any shaded module affects the whole string. Selective deployment of optimization on only the shaded modules improves performance for unshaded modules.
Use Cloud Connect and Gateway to enable monitoring capabilitiesClick here to continue
Modularity and Selective Deploymentx 4 x 6
kW
TS4-DTS4-O x 2Click to continueWithout optimization, any shaded module affects the whole string. Selective deployment of optimization on only the shaded modules improves performance for unshaded modules.
Step 1: Select the Basic Functionality that Addresses your NeedsStep 2: Identify shaded areas and optimize utilizing PIVApplicable for ANY STANDARD MODULE and does NOT require communication!Click here to continueModularity and Selective DeploymentStep 1: Select the Basic Functionality that Addresses your NeedsIs Rapid Shutdown required? Click Yes or No
YesNeed to comply with NEC 690.12NoEverything in this presentation refers to a single string per inverter, or a single string per MPPT deployment
Click here for guidelines on multiple strings and non-residential systemsClick here for specific use cases, for example different orientationsClick here for more on the Cloud Connect and Gateway placementThank you for taking the tour!Here are a few useful notes
MPPT 1MPPT 2
Single MPPT
Modularity and Selective DeploymentStep 3: If the design is still not satisfying system needsx 8
kWTS4-LClick to continueWith longer string you also get built-in optimization. Now, shaded module doesnt affect the whole string and energy gain is maximal
Step 2: Identify shaded areas and optimize utilizing PIV
Applicable for ANY STANDARD MODULE and does NOT require communication! Use Cloud Connect and Gateway only if safety or monitoring capabilities are requiredWere it not for voltage limitations, could the roof accommodate more modules?Use TS4-L to maximize roof and inverter potential by extending the string length
Without optimization, energy loss is 60% to 70% higher