respiratory protection program city of los angeles personnel department presented by: zuhdy youssef,...

16
Respiratory Protection Respiratory Protection Program Program City of Los Angeles Personnel Department Presented by: Zuhdy Youssef, MS, CIH, CSP Senior Industrial Hygienist

Upload: louis-racy

Post on 31-Mar-2015

215 views

Category:

Documents


3 download

TRANSCRIPT

Page 1: Respiratory Protection Program City of Los Angeles Personnel Department Presented by: Zuhdy Youssef, MS, CIH, CSP Senior Industrial Hygienist

Respiratory Protection Respiratory Protection ProgramProgram

City of Los AngelesPersonnel Department

Presented by: Zuhdy Youssef, MS, CIH, CSP Senior Industrial Hygienist

Page 2: Respiratory Protection Program City of Los Angeles Personnel Department Presented by: Zuhdy Youssef, MS, CIH, CSP Senior Industrial Hygienist

Introduction Introduction

Cal/OSHA RegulationsWritten Program & DocumentationProgram Administrator

Page 3: Respiratory Protection Program City of Los Angeles Personnel Department Presented by: Zuhdy Youssef, MS, CIH, CSP Senior Industrial Hygienist

RespiratorsRespirators

Approval:NIOSH National Institute for Occupational

Safety and Health

Regulations:Federal CFR 1910.134State Cal/OSHA Title 8, Sec. 5144Website www.dir.ca.gov/title8/5144.html

Page 4: Respiratory Protection Program City of Los Angeles Personnel Department Presented by: Zuhdy Youssef, MS, CIH, CSP Senior Industrial Hygienist

Program Elements Program Elements

1. Exposure Assessment2. Hazard Control3. Selection, Fitting, & Training4. Sanitization & Care5. Storage6. Medical Evaluation

Storage

Medicalevaluation

Care

Assess- ment

Control

Fitting

Page 5: Respiratory Protection Program City of Los Angeles Personnel Department Presented by: Zuhdy Youssef, MS, CIH, CSP Senior Industrial Hygienist

Exposure AssessmentExposure AssessmentMSDS ReviewEmployees AwarenessMonitoring Personal Sampling

Area Sampling

Type of Contamination Duration of ExposureConsult Industrial Hygiene Unit

(213) 473-7097 Dru Ross

Page 6: Respiratory Protection Program City of Los Angeles Personnel Department Presented by: Zuhdy Youssef, MS, CIH, CSP Senior Industrial Hygienist

Hazard ControlHazard Control

Engineering ControlLocal Exhaust SystemGeneral Dilution Ventilation

Administrative ControlSubstitutionReduce Exposure TimeIsolation of HazardMinimize Number of Employees ExposedChange of Process

Personal Protective EquipmentRespirators, Face Shield, Gloves, …etc.

Page 7: Respiratory Protection Program City of Los Angeles Personnel Department Presented by: Zuhdy Youssef, MS, CIH, CSP Senior Industrial Hygienist

Selection, Fitting, & TrainingSelection, Fitting, & Training

SelectionAir Purifying Respirators

Mechanical FiltersChemical CartridgesPowered Air Purifying Respirator

Atmosphere Supplying RespiratorSupply Air-LineSelf-Contained Breathing Apparatus

(SCBA)

Page 8: Respiratory Protection Program City of Los Angeles Personnel Department Presented by: Zuhdy Youssef, MS, CIH, CSP Senior Industrial Hygienist

Selection, Fitting, & TrainingSelection, Fitting, & TrainingAir Purifying Respirator Types:Air Purifying Respirator Types:

Mechanical Filter Chemical Cartridges

Powered Air Purifying Respirator

Page 9: Respiratory Protection Program City of Los Angeles Personnel Department Presented by: Zuhdy Youssef, MS, CIH, CSP Senior Industrial Hygienist

Selection, Fitting, & TrainingSelection, Fitting, & TrainingAtmosphere Supplying Respirator Types:Atmosphere Supplying Respirator Types:

Supply Air-Line Self-Contained Breathing Apparatus (SCBA)

Page 10: Respiratory Protection Program City of Los Angeles Personnel Department Presented by: Zuhdy Youssef, MS, CIH, CSP Senior Industrial Hygienist

Selection, Fitting, & TrainingSelection, Fitting, & Training

Criteria for SelectionNature of HazardCharacteristic of The Hazardous OperationLocation of Hazardous AreaTime Respirator Protection May Be RequiredActivity of WorkersLimitation of Respirator TypesRespirator Fit Factors

Color Code of Cartridges & Gas Masks

Page 11: Respiratory Protection Program City of Los Angeles Personnel Department Presented by: Zuhdy Youssef, MS, CIH, CSP Senior Industrial Hygienist

Selection, Fitting, & TrainingSelection, Fitting, & TrainingCartridges Color Code & Gas Masks

Some Common Cartridge Color Coded

Color Cartridge Use Guide

  Acid - AG

  Organic Vapor - OV

 Acid, Gas and Organic Vapor - AG / OV

  Ammonia and Methylamine

  Formaldehyde and certain OV

  Radioactive material - P100

  Multi-Gas and certain OV

 Mercury Vapor or Certain Chlorine Gas

 

Page 12: Respiratory Protection Program City of Los Angeles Personnel Department Presented by: Zuhdy Youssef, MS, CIH, CSP Senior Industrial Hygienist

Selection, Fitting, & TrainingSelection, Fitting, & TrainingProtection factor

Air Purifying Respirator P. F.Single Use Dust Mask 5Half-Mask Dust Respirator 10Full-Face “HEPA” Mask 50Powered High Efficiency 1,000Gas & Vapor Half-Mask 10Gas & Vapor Full-Face Piece 50

Atmosphere SupplyingSupplied Air-Line 10-2,000SCBA 50-10,000

P. F. = Contamin. Conc. In Ambient Air Contamin. Conc. Inside the Mask

Page 13: Respiratory Protection Program City of Los Angeles Personnel Department Presented by: Zuhdy Youssef, MS, CIH, CSP Senior Industrial Hygienist

Selection, Fitting, & TrainingSelection, Fitting, & Training Respirator Fit Test

Positive/Negative Pressure CheckQualitative Fit TestsQuantitative Fit Tests

TrainingRespiratory HazardRespiratory SelectionFunctions, Capabilities, & LimitationsProper Wearing of RespiratorsRespirator Maintenance, Cleaning, & StorageEmergency Situations

Page 14: Respiratory Protection Program City of Los Angeles Personnel Department Presented by: Zuhdy Youssef, MS, CIH, CSP Senior Industrial Hygienist

Sanitization & CareSanitization & Care

All RespiratorsBefore And After Each Use

Emergency Respirators & SCBAAt Least Monthly

Cleaning Procedures

Page 15: Respiratory Protection Program City of Los Angeles Personnel Department Presented by: Zuhdy Youssef, MS, CIH, CSP Senior Industrial Hygienist

StorageStorage

Store Respirator Properly

Storage Cabinets Should Be Clearly Marked

Page 16: Respiratory Protection Program City of Los Angeles Personnel Department Presented by: Zuhdy Youssef, MS, CIH, CSP Senior Industrial Hygienist

Medical EvaluationMedical Evaluation

Questionnaire or Initial Evaluation