resstance or12 thermometer - ordel · sf (certification) w (thermowell) t (teflon coating) th...

3
221 SOCKET CONNECTION RESISTANCE THERMOMETER - OR12 OR12 series resistance thermometer, it is designed to be used for temperature measurement in industrial environmensts.Complying international standards,reliability and user friendly usage features are the design principles of these devices.Particular,food industry and hygiene to be preferred in the process. Sensor Types ( Pt-100, Pt-500, Pt-1000, N-100, N-1000 ) Hygenc Connecton Opton M12 Connecton (IP66) DIN 43650 Electrcal Connecton OR12 M12 and DIN 43650 Socket Connecton Resstance Thermometer GOST TS EN ISO/EC 17021 AB-022-YS Device Featıres

Upload: others

Post on 05-Jul-2020

4 views

Category:

Documents


0 download

TRANSCRIPT

Page 1: Resstance OR12 Thermometer - Ordel · SF (Certification) W (Thermowell) T (Teflon Coating) TH (Teflon Hose) Immersion Length : 5 10 15 20 25 30 40 80 Note : 10mm....5000mm Between

220 221SOCKET CONNECTION RESISTANCE THERMOMETER - OR12

OR12 series resistance thermometer, it is designed to be used for temperature m e a s u r e m e n t i n i n d u s t r i a l environmensts.Complying international standards,reliability and user friendly usage features are the design principles of these devices.Particular,food industry and hygiene to be preferred in the process.

Sensor Types ( Pt-100, Pt-500, Pt-1000, N�-100, N�-1000 )Hyg�en�c Connect�on Opt�onM12 Connect�on (IP66)DIN 43650 Electr�cal Connect�on

OR12

M12 and DIN 43650 Socket Connect�onRes�stanceThermometer

GOSTTS EN ISO/EC 17021

AB-022-YS

Device Featıres

Our company, unless notified, reserves all rights to make changes on its products.

Page 2: Resstance OR12 Thermometer - Ordel · SF (Certification) W (Thermowell) T (Teflon Coating) TH (Teflon Hose) Immersion Length : 5 10 15 20 25 30 40 80 Note : 10mm....5000mm Between

222SOCKET CONNECTION RESISTANCE THERMOMETER - OR12

Pt-100 Resistance Thermometer

Pt-500 Resistance Thermometer

Pt-1000 Resistance Thermometer

Ni-100 Resistance Thermometer

Ni-1000 Resistance Thermometer

Resistance Thermometer Type Coding

OR12 - _ _ _ _ _ - _ - _ _

P�cture No :A1A2 - Hyg�en�c TypeA3 - Hyg�en�c TypeA4A5 - Hyg�en�c TypeA6 - Hyg�en�c Type

Elektr�cal Connect�on :1 = DIN 43650 Valve Socket2 = M12 x 1 Socket

Element Type :A = A Class Pt-100B = B Class Pt-100C = Pt-1000D = Pt-500E = N�-100F = N�-1000

Outer Protect�ve Sheath Mater�al :EFBHJ

NOTE:When the outer protect�ve sheath of m�neral �nsulated asked to “0" w�ll be coded.

Outer Protect�ve Sheath D�ameter :06080911121415

M�neral Insulated Outer Protect�ve D�ameter :20 = 2 mm30 = 3 mm45 = 4,5 mm60 = 6 mm80 = 8 mm

Special Cases :RX* (Record)RA (Adjustable Record)F (Flange)HD (Hole for air)Ö (Special)SF (Certification)W (Thermowell)T (Teflon Coating)TH (Teflon Hose)

Immersion Length :510152025304080Note : 10mm....5000mm Between All Lengths

==

======

========

50 mm100 mm150 mm200 mm250 mm300 mm400 mm800 mm

=

1,4301 (AISI 131 304)1,4401 (AISI 131 316)1,4404 (AISI 131 316L)1,4571 (AISI 131 316TI)1,4541 (AISI 131 321)

6 mm8 mm9 mm

11 mm12 mm14 mm15 mm=

223SOCKET CONNECTION RESISTANCE THERMOMETER - OR12

Product Shapes

L L

d d dL

L L

d d dL

M12 x 1 Socket

DIN 43650 Valve Socket

A1 A2 - Hygienic Type A3 - Hygienic Type

A4 A5 - Hygienic Type A6 - Hygienic Type

RR

RR

Sensor Type Standard Temperature Range

Product Code

==

Our company, unless notified, reserves all rights to make changes on its products.

Page 3: Resstance OR12 Thermometer - Ordel · SF (Certification) W (Thermowell) T (Teflon Coating) TH (Teflon Hose) Immersion Length : 5 10 15 20 25 30 40 80 Note : 10mm....5000mm Between

222SOCKET CONNECTION RESISTANCE THERMOMETER - OR12

Pt-100 Resistance Thermometer

Pt-500 Resistance Thermometer

Pt-1000 Resistance Thermometer

Ni-100 Resistance Thermometer

Ni-1000 Resistance Thermometer

Resistance Thermometer Type Coding

OR12 - _ _ _ _ _ - _ - _ _

P�cture No :A1A2 - Hyg�en�c TypeA3 - Hyg�en�c TypeA4A5 - Hyg�en�c TypeA6 - Hyg�en�c Type

Elektr�cal Connect�on :1 = DIN 43650 Valve Socket2 = M12 x 1 Socket

Element Type :A = A Class Pt-100B = B Class Pt-100C = Pt-1000D = Pt-500E = N�-100F = N�-1000

Outer Protect�ve Sheath Mater�al :EFBHJ

NOTE:When the outer protect�ve sheath of m�neral �nsulated asked to “0" w�ll be coded.

Outer Protect�ve Sheath D�ameter :06080911121415

M�neral Insulated Outer Protect�ve D�ameter :20 = 2 mm30 = 3 mm45 = 4,5 mm60 = 6 mm80 = 8 mm

Special Cases :RX* (Record)RA (Adjustable Record)F (Flange)HD (Hole for air)Ö (Special)SF (Certification)W (Thermowell)T (Teflon Coating)TH (Teflon Hose)

Immersion Length :510152025304080Note : 10mm....5000mm Between All Lengths

==

======

========

50 mm100 mm150 mm200 mm250 mm300 mm400 mm800 mm

=

1,4301 (AISI 131 304)1,4401 (AISI 131 316)1,4404 (AISI 131 316L)1,4571 (AISI 131 316TI)1,4541 (AISI 131 321)

6 mm8 mm9 mm

11 mm12 mm14 mm15 mm=

223SOCKET CONNECTION RESISTANCE THERMOMETER - OR12

Product Shapes

L L

d d dL

L L

d d dL

M12 x 1 Socket

DIN 43650 Valve Socket

A1 A2 - Hygienic Type A3 - Hygienic Type

A4 A5 - Hygienic Type A6 - Hygienic Type

RR

RR

Sensor Type Standard Temperature Range

Product Code

==