3-WireRadio-IntercomUpdating Guide

Older 3-wire systems may be converted to an IM-3303 Series Radio-Intercom System.This booklet outlines the updating procedure; indicating the components that may be retainedfrom the existing system and the units that should be replaced.NOTE: Due to component size differences, some wall patching may be required wheninstalling new systems.

IMPORTANT: The Radio-Intercom Systems are designed to be used only with NuTone specified wire. No other wire should be used. The use of wire other than NuTone wire may result in faulty installation andimproper operation. Refer to the installation instructions packaged with each model for detailed installationinformation.

Master Station:IM-3303WH Bright White FinishIM-3303L Biscuit Finish

• System may include a maximum of thirteen (13) remotespeakers and three (3) door speakers.

Wiring Requirements:Three-wire system.

• Maximum of 300 feet per remote station.• Maximum of 2000 feet total per system.

Rough-In Frame for Master Station:Model IR-104 Rough-In Frame(includes (2) Model 301T transformers and omni-directional AM/FM antenna.)

Power Source:(2) Model 301T transformers (16 volt, 30VA.)Mounts in transformer boxes located in bottom of rough-in frame.

MASTER VOLUME

PROGRAM OFF

SCAN

SET RADIOTIME

AMPM KHz

MHz12:00

MEMORY 1AM

MEMORY 2FM

MEMORY 3CD/TAPE

MEMORY 4AUX

MEMORY 5TIMER

MEMORY 6INSIDE/PATIO

END CALL

DOOR TALK

ON OFF

IM-3303 Series

Page 3: RETRO FIT UPDATING GUIDE

3

UPDATING 3-WIRE RADIO-INTERCOM SYSTEMS

Master Station Model Numbers: 2011, 2012, 2015 or 2016

Wiring Requirements:Use existing 3-conductor wiring from the master station to remotes.AM only systems will require the installation of the FM/AM antenna.

Rough-In Frame for Master Station:Replace existing rough-in and patch wall surface as necessary.Use IR-104 Rough-In.

Power Source:Use transformer(s) supplied with new rough-in housing.

5" Speakers with Controls:Replace existing inside speakers with 5" speakers and IA-51 Surface Mount Update Frame or IA-55WH/L UpdateFrame. Or, install 8" speakers with IR-80 Rough-In.

8" Speakers with Controls:Replace existing 8" speakers.Use existing speaker frames and wiring. (Wall patching may be required)

Remote Controls:Replace existing remote controls.For inside remotes, remove 3-gang switch box and replace with IR-91 Update Frame.

Speakers without Controls:Replace existing speakers.Use existing speaker frames and wiring.

Door Speakers:Replace existing speakers. Use existing wiring and Rough-Ins. Note: For door speakers that include a chime pushbutton, an additional two-conductor wire will be required.

Master Station Model Numbers: 2031, 2032, 2034-2036, 2053-2058,2062-2065, 2067, 2068, 2090 or 2091

Wiring Requirements:Use existing 3-conductor wiring from the master station to remotes.AM only systems will require the installation of the FM/AM antenna.

Rough-In Frame for Master Station:Remove and replace with model IR-104.Use Updating Frame IA-119WH (white finish).

Power Source:Existing source is a remotely located transformer (120vAC or 30vAC).Install (2) 301T transformers (supplied with IR-104 Rough-In) for IM-3303.

5" Speakers with Controls:Replace existing inside speakers with 5" speakers and IA-55WH/L Update Frame.Or, use 8" speakers with IR-80 Rough-In.

8" Speakers with Controls:Replace existing 8" speakers; use IA-83WH/L Update Frame and IR-80 Rough-In.

Remote Controls:Replace existing remote controls.For inside remotes, remove 2- or 3-gang switch box and replace with IR-91 Rough-In.

Speakers without Controls:Replace existing speakers.Use existing wiring and rough-in frames.

Door Speakers:Replace existing speakers. Use existing wiring and Rough-Ins. Note: For door speakers that include a chime pushbutton, an additional two-conductor wire will be required.

Page 4: RETRO FIT UPDATING GUIDE

4

UPDATING 3-WIRE RADIO-INTERCOM SYSTEMS (continued)

Master Station Model Numbers: IM/IMA-203

Wiring Requirements:Use existing 3-conductor wiring from the master station to remotes.

Rough-In Frame for Master Station:Remove and replace with model IR-104.Use Updating Frame IA-119WH (white finish).

Power Source:Install (2) 301T transformers (supplied with IR-104) for IM-3303.

5" Speakers with Controls:Replace existing inside speakers with 5" speaker. Replace Rough-In with model IR-50.

8" Speakers with Controls:Replace existing 8" speaker. Use IA-83WH/L update frame and IR-80 Rough-In.

Remote Controls:Replace existing Remote Controls. Use IR-91 Rough-In.

Speakers without Controls:Use existing speakers.

Door Speakers:Replace existing speakers. Use existing Rough-In.Door speakers with chime pushbuttons will require an additional two-conductor wire.

Master Station Model Numbers: IM/IMA-303, IM/IMA-323IM-, IMA, B-, C-, D-313

Wiring Requirements:Use existing 3-conductor wiring from the master station to remotes.

Rough-In Frame for Master Station:Remove and replace with model IR-104.Use Updating Frame IA-109WH (white finish) for IM-3303.NOTE: For 313 Series, the wall must be framed and patched to accommodate the IR-104 for Rough-In.

Power Source:Install (2) 301T transformers (supplied with IR-104).

5" Speakers with Controls:Remove existing speakers and rough-ins.Install IR-50 Rough-Ins and replace speakers.

8" Speakers with Controls:Replace existing speakers.Use IA-83WH/L Updating Frames and IR-80 Rough-Ins.

Remote Controls:Replace existing units.For inside locations, remove 3-gang switch box and install IR-91 Rough-In.

Speakers without Controls:Use existing units. Use existing wiring and rough-in frames.

Door Speakers:Existing door speaker may be used.

NOTE: IM-3303 systems donot include the SecurityProtection features of theIMA-323.

Page 5: RETRO FIT UPDATING GUIDE

UPDATING 3-WIRE RADIO-INTERCOM SYSTEMS (continued)

5

Master Station Model Number: 2071Wiring Requirements:

Use existing 5-conductor wiring from the master station to remotes (connections to 3-conductors on Channel “A”).NOTE: For Channel “B” speaker, the wall must be patched.

Rough-In Frame for Master Station:Remove and replace with IR-104.Use Updating Frame IA-119WH (white finish).

Power Source:Install (2) 301T transformers (supplied with IR-104) for IM-3303.

5" Speakers with Controls:Replace existing inside speakers with 5" speakers use IA-55WH/L Update Frame.Or, use 8" speakers with IR-80 Rough-In.

8" Speakers with Controls:Replace existing 8" speakers.Use IA-83WH/L Updating Frame and IR-80 Rough-In.

Remote Controls:Replace existing remote controls.For inside remotes, remove 2- or 3-gang switch box and replace with IR-91 for IM-3303 (wall patching may be required).

Speakers without Controls:Replace existing speakers.Use existing wiring and rough-in frames.

Door Speakers:Replace existing speakers.Use existing wiring and rough-in frames.Door speakers with chime pushbuttons will require an additional two-conductor wire.

Master Station Model Number: IM-3103Wiring Requirements:

Use existing 3-conductor wiring from the master station to remotes.Use existing AM/FM antenna.

Rough-In Frame for Master Station:Frame and patch the wall to accommodate IR-104.

Power Source:Install (2) 301T transformers (supplied with IR-104 Rough-In).

5" Speakers with Controls:Use existing speakers.

8" Speakers with Controls:Use existing speakers.

Remote Controls:Use existing remote controls when installing an IM-3303 System.

Speakers without Controls:Use existing speakers.

Door Speakers:Use existing speakers. Use existing wiring and Rough-Ins.

Page 6: RETRO FIT UPDATING GUIDE

6

OPTIONAL ACCESSORIESUPDATING 3-WIRE RADIO-INTERCOM SYSTEMS (continued)

Master Station Model Number: IM-3003Wiring Requirements:

Use existing 3-conductor wiring from the master station to remotes.Use existing AM/FM antenna.

Rough-In Frame for Master Station:For IM-3303, remove and replace with IR-104 or leave frame in place, but replace 105T transformer with two (2) 301T transformers, remote mounted. Observe local electrical codes.

Power Source:Install (2) 301T transformers (supplied with IR-104).

5" Speakers with Controls:Use existing speakers.

8" Speakers with Controls:Use existing speakers.

Remote Controls:Use existing remote controls.

Speakers without Controls:Use existing speakers, wiring and rough-in frames.

Door Speakers:Use existing speakers, wiring and rough-in frames.

IR-6Housing for built-in DoorSpeakers.

Cutout: 311⁄16" wide x 5" high.

ROUGH-INS

311/16"

5"

13/4"

IR-70Housingfor IS-76RoundSpeaker.

Cutout: 103⁄4" diameter.

23/4"

23/4"

12 1/4"

12 3/8"

11/16"

10 3/4"

IR-91Housing for IC-331Remote Control.Cutout:

61⁄8" wide x 31⁄4"high.

31/4"

61/8"

IR-90Housing for CP-95Cassette Deck.

Cutout: 141⁄2" wide x 21⁄4" high.

21/4"141/2"

IR-9Housing for IS-79 WallCutout.

Dimensions: 101⁄16" wide x 73⁄16" high.

25/8"

111/16"

101/16"

IR-50Housing for 5" Inside Speakers.

Cutout: 53⁄8" wide x 73⁄16" high.

73/16"

53/8" 11/4"

IR-55Housing for Recessed PatioSpeakers.Cutout: 53⁄8" wide x 73⁄16"high.

7 3/16"

53/8"

IR-80Housing for 8"Inside Speakers.

Cutout: 85⁄8" x 85⁄8" high.

85/8" 11/2"

101/4"

IR-104Housing for MasterStations. includestransformer and omni-directional FM/AMantenna.

Cutout: 141⁄2" wide x 7" high.

141/2"

7"

33/8"

Page 7: RETRO FIT UPDATING GUIDE

7

To update all older 3-wire MasterStations except 2015/16 and 2011/12.

Update frames are not available for 2015/16 or 2011/12.

UPDATE FRAMES

REMOTE SPEAKER UPDATE FRAMES

IA-119WH Bright White• For use with IM-3303WH.

IA-51Surface MountAdobe WhiteTo update 5"horizontalspeakers fromolder systems to IS-335 Series.

IA-55WH/LBright WhiteTo update 5"horizontalspeakers fromolder systems to IS-335 Series.

IA-83WH/LPrimer WhiteTo update larger speakers fromolder systems to IS-338 Series.

OPTIONAL ACCESSORIESChime Modules

• Model IA-28: Plays eight (8) notes for front door, two (2) notesfor rear door and one (1) note for a third door.

• Model IA-29: Deluxe Chime Module plays your choice of ten(10) melodies for front door, plus two (2) notes for rear door,one (1) note for a third door. Melodies include WestminsterChimes (8 notes and 4 notes), Anniversary Waltz, Beethoven'sFifth, Dixie, Greensleeves, Happy Birthday, Jingle Bells, JoyTo The World, Mazel Tov, Oh Tannenbaum, and Star SpangledBanner.

• A NuTone Electronic Chime may also be used with the Radio-Intercom System.

Cassette DeckModel CP-95

• Auto-reverse Cassette Deck recesses in the wall near theMaster Station. Lets you enjoy your favorite cassette tapesfrom any speaker station.

• White finish coordinates with Master Stations. Installs in IR-90Rough-In Frame (sold separately).

• Controls include fast forward, rewind and eject. Includesstorage compartment for four (4) tapes.

Refer to NuTone's catalog for complete product information.

Page 8: RETRO FIT UPDATING GUIDE

6/8-WireRadio-IntercomUpdating Guide

Older 6/8-wire systems may be converted to an IM-4406 or IM-5000 Series Radio-Intercom System.This booklet outlines the updating procedure; indicating the components that may beretained from the existing system and the units that should be replaced.

IMPORTANT: The Radio-Intercom Systems are designed to be used only with NuTone specified wire. No other wire should be used. The use of wire other than NuTone wire may result in faulty installationand improper operation. Refer to the installation instructions packaged with each model for detailedinstallation information.

Master Station:IM-4406L Biscuit FinishIM-4406BL Black FinishIM-4406WH Bright White Finish

• System may include up to nine (9) remote stations andthree (3) door speakers.NOTE: NuTone Model IA-440 Expansion Kit (soldseparately) will allow up to 15 remote stations andthree (3) door speakers to be used with the system.

Wiring Requirements:An individual 6-wire cable (NuTone IW-6) must be“Home Run” from each remote station to the masterstation's terminal board.

• Maximum speaker run: 750 feet.• Maximum total of IW-6 per system: 4000 feet.

Rough-In Frame for Master Station:Model IR-105 Rough-In Frame(includes (2) Model 801T transformers andomni-directional AM/FM antenna.)

Power Source:(2) Model 801T transformers (18 volts, 72VA.)Mounts in transformer box located in bottom of rough-in frame.

Master Station:IM-5000 Bright White Finish

• System will accommodate up to 20 remote stationsplus up to three (3) door speakers.

Wiring Requirements:An individual 6-wire cable (NuTone IW-6) must beconnected to each remote station.

• Maximum speaker run: 750 feet.• Maximum total of IW-6 per system: 4000 feet.

NOTE: For best results it is suggested that the IM-5000Intercom System is installed in such a way that acombination of “Home Run” wiring and “Looped” wiring(zone wiring) are both used.

IM-5000 is surface mounted. No Rough-In Required.Power Source: (Purchase Separately)

One (1) Model 401T transformer (24 volts, 40VA.)

IM-4406 Series

IM-5000 Series

Page 9: RETRO FIT UPDATING GUIDE

9

UPDATING 6/8-WIRE RADIO-INTERCOM SYSTEMS

Master Station Model Numbers: 2540, 2541

Wiring Requirements:Use existing 6-conductor wiring from the master station to remote locations.

Rough-In Frame for Master Station:IM-4406 - Remove and replace with IR-105 Rough-In Frame.*IM-5000 - (Surface mounted).

Power Source:IM-4406: Use (2) transformers Model 801T (included with Rough-In Frame).IM-5000: Use (1) transformer Model 401T.

5" Speakers with Controls:Remove and replace existing speakers and rough-ins.

8" Speakers with Controls:Remove and replace existing speakers. Use IA-83 Updating Frame and IR-80 Rough-Ins.

Remote Controls:Replace existing remote controls.IM-4406: Replace 3-gang box with IR-91.IM-5000: Replace 3-gang box with IR-91.NOTE: Wall patching may be required.

Speakers without Controls:Replace existing speakers. Use existing wiring and rough-in frames.

Door Speakers:Replace existing speakers. Use existing wiring and rough-in frames.NOTE: For door speakers that include a chime pushbutton, an additional two-conductor wire will be required.

Master Station Model Number: 2542

Wiring Requirements:Use existing 6-conductor wiring from the master station to remote locations.

Rough-In Frame for Master Station:Frame and patch the wall to accommodate the IR-105 rough-in frame for the IM-4406 Master Station. *The IM-5000 is surface mounted.

Power Source:IM-4406: Use (2) transformers Model 801T (included with Rough-In Frame).IM-5000: Use (1) transformer Model 401T.

5" Speakers with Controls:Remove and replace existing speakers and rough-ins.

8" Speakers with Controls:Remove and replace existing speakers. Use IA-83 Updating Frame and IR-80 Rough-Ins.

Remote Controls:Replace existing remote controls.IM-4406: Replace 3-gang box with IR-91.IM-5000: Replace 3-gang box with IR-91.NOTE: Wall patching may be required.

Speakers without Controls:Replace existing speakers. Use existing wiring and rough-in frames.

Door Speakers:Replace existing speakers. Use existing wiring and rough-in frames. NOTE: For door speakers that include a chime pushbutton, an additional two-conductor wire will be required.

*The IM-5000 can be mounted remotely (i.e., pantry, closet, etc.) and existing master replaced with 8" speaker withcontrols (wall patching required). Wiring from existing master must be extended to IM-5000 location.

Page 10: RETRO FIT UPDATING GUIDE

10

UPDATING 6/8-WIRE RADIO-INTERCOM SYSTEMS (continued)Master Station Model Numbers: 2561, 2562

NOTE: If the existing system is loop or partially loop wired, it can only be converted to an IM-5000 system.If the existing system is a completely “home run” system (i.e. one 8 wire cable for every remote at the master station)then the system can be converted to either an IM-4406 or an IM-5000 System.Wiring Requirements:

Use six (6) of the existing 8-conductor wiring from the master station to remote stations (blue pair not used).Rough-In Frame for Master Station:

Remove and replace with rough-in frame for the IM-4406 (IR-105). NOTE: Wall patching may be required. *The IM-5000 is surface mounted.

Power Source:IM-4406 - Use (2) transformers Model 801T (included with rough-in frame).IM-5000 - Use (1) transformer Model 401T.

5" Speakers with Controls:IM-4406: Replace existing inside speakers with 5" speakers and IA-51 or IA-55 Adapter Frame.

Or, install 8" speakers with IR-80 Rough-In Frame.IM-5000: Replace existing inside speakers with 5" speakers and IA-51 or IA-55 Adapter Frame.

Or, install 8" speakers with IR-80 Rough-In Frame. NOTE: Wall patching may be required.8" Speakers with Controls:

Replace existing speakers. Use IA-83 Updating Frame and IR-80 Rough-Ins. NOTE: Wall patching may be required.Remote Controls:

IM-4406: Replace existing remote controls. Replace 2-gang switch box with IR-91 Rough-In Frame.IM-5000: Replace existing remote controls. Replace 2-gang switch box with IR-91 Rough-In Frame.NOTE: Wall patching may be required.

Speakers without Controls:Replace existing speakers. Use existing wiring and rough-in frames.

Door Speakers:Replace existing speakers. Use existing wiring and rough-ins.NOTE: For door speakers that include a chime pushbutton, an additional two-conductor wire will be required.

Master Station Model Number: SM-428

NOTE: If the existing system is loop or partially loop wired, it can only be converted to an IM-5000 System. If the existingsystem is completely “home run” system (i.e. one 8-wire cable for every remote at the master station), then the systemcan be converted to either an IM-4406 or IM-5000 System.

Wiring Requirements:Use six (6) of the existing 8-conductor wires from the master station to remote locations (blue pair not used).NOTE: For Channel “B” speaker, the wall must be patched.

Rough-In Frame for Master Station:Remove and replace with rough-in frame for the IM-4406 (IR-105). NOTE: Wall patching may be required.*The IM-5000 is surface mounted.

Power Source:IM-4406 - Use (2) transformers Model 801T (included with Rough-In frame). IM-5000 - Use (1) transformer Model 401T.

5" Speakers with Controls:Remove existing speakers and rough-in frames.Install IR-50 Rough-Ins and install new speakers.

8" Speakers with Controls:Replace existing speakers. Use IA-83 Updating Frame and IR-80 Rough-Ins. NOTE: Wall patching may be required.

Remote Controls:Replace existing remote controls.

IM-4406: Replace 3-gang box with IR-91IM-5000: Replace 3-gang box with IR-91. NOTE: Wall patching may be required.

Speakers without Controls:Existing wiring, rough-ins and speakers may be used.

Door Speakers:Existing wiring, rough-ins and speakers may be used.

*The IM-5000 can be mounted remotely (i.e., pantry, closet, etc.) and existing master replaced with 8" speaker with controls(wall patching required). Wiring from existing master must be extended to IM-5000 location.

Page 11: RETRO FIT UPDATING GUIDE

11

UPDATING 6/8-WIRE RADIO-INTERCOM SYSTEMS (continued)

Master Station Model Numbers: IM/IMA-406NOTE: If the existing system is loop or partially loop wired,it can only be converted to an IM-5000 System. If theexisting system is completely “home run” system (i.e. one6-wire cable for every remote at the master station), thenthe system can be converted to either an IM-4406 orIM-5000 System.Wiring Requirements:

Use existing 6-conductor wiring from master station to remote locations.

Rough-In Frame for Master Station:Remove and replace with rough-in frame IR-105 forIM-4406 or surface mount *IM-5000 Master Station.Note: Wall patching may be required.

Power Source:IM-4406: Use (2) 801T transformers included withIR-105 Rough-In Frame.IM-5000: Use (1) 401T transformer.

5" Speakers with Controls:Remove existing speakers and rough-in frames. Install IR-50 Rough-Ins and install new speakers.

8" Speakers with Controls:Replace existing speakers. Use IA-83 Updating Frameand IR-80 Rough-Ins.NOTE: Wall patching may be required.

Remote Controls:Replace existing remote controls.IM-4406: Replace 3-gang box with IR-91.IM-5000: Replace 3-gang box with IR-91.NOTE: Wall patching may be required.

Speakers without Controls:Existing wiring, rough-ins and speakers may be used.

Door Speakers:Existing wiring, rough-ins and speakers may be used.

Master Station Model Numbers: 470, IM/IMA-516Power Source:

IM-4406: Use (2) 801T transformer(s) included withIR-105 Rough-In Frame. IM-5000: Use (1) 401Ttransformer.

Speakers with Controls:Remove and replace existing speakers and rough-ins with IR-50 or IR-80 Rough-In Frames and 5" or 8" Speakers.NOTE: Wall patching may be required..

Door Speakers:Replace existing speakers. Use existing wiring and rough-in frames.

NOTE: If existing system is loop or partially loop wired, it can only be converted to an IM-5000 system.If the existing system is a completely “home run” system

(one 6 wire cable for every remote at the master station) then the system can be converted to either an IM-4406 or IM-5000 System.

Wiring Requirements:Use existing 6-conductor wiring from master station to remote locations.

Rough-In Frame for Master Station:Install IR-105 rough-in frame for either IM-4406 or surface mount IM-5000 Master Station.

*The IM-5000 can be mounted remotely (i.e., pantry, closet, etc.) and existing master replaced with 8" speaker withcontrols (wall patching required). Wiring from existing master must be extended to IM-5000 location.

Master Station Model Number: IM/IMA-4006Wiring Requirements:

IM-4006 - Use existing 6-conductor wiring from masterstation to remote locations. Systems that used 6-wireribbon cable can be used by separating the ribboncable into 6 individual wires. Follow wiring guidesupplied with IM-4406 Master.IMA-4006 - Use existing 6-conductor wiring from themaster station to remote locations.

Rough-In Frame for Master Station:IM-4406 - Remove and replace with IR-105 rough-inframe.

Power Source:IM-4406: Use (2) 801T transformers included withrough-in frame.

5" Speakers with Controls:Use existing speakers and rough-ins.

8" Speakers with Controls:Use existing speakers and rough-ins.

Remote Controls:Use existing remote controls and rough-ins.

Speakers without Controls:Use existing speakers. Use existing wiring and rough-inframes.

Door Speakers:Use existing speakers. Use existing wiring and rough-inframes.

Page 12: RETRO FIT UPDATING GUIDE

12

UPDATING 6/8-WIRE RADIO-INTERCOM SYSTEMS (continued)

Master Station Model Number: IM/IMA-8065" Speakers with Controls:

Remove existing speakers and rough-in frames. Install IR-50 Rough-Ins and install new speakers.

8" Speakers with Controls:Remove and replace existing speakers. Use IA-83Updating Frame with IR-80 Rough-In Frames.NOTE: Wall patching may be required.

Remote Controls:Remove and replace existing rough-ins and controls.NOTE: Wall patching may be required at the top and bottom of the unit.

Speakers without Controls:Existing wiring, rough-ins and speakers may be used.

Door Speakers:Existing wiring, rough-ins and speakers may be used.

NOTE: If existing system is loop or partially loop wired, it can only be converted to an IM-5000 system.If the existing system is a completely “home run” system

(one 6 wire cable for every remote at the master station) then the system can be converted to either an IM-4406 or IM-5000 System.Telephone answering from the master and remote

stations will no longer be a feature of the system.

Wiring Requirements:Use existing 6-conductor wiring from master station to remote locations.

Rough-In Frame for Master Station:Remove and replace with rough-in frame IR-105 forIM-4406 or surface mount *IM-5000 Master Station.

Power Source:Use (2) 801T transformer(s) included with the IM-4406Rough-in or (1) 401T transformer for the IM-5000Master Station.

*The IM-5000 can be mounted remotely (i.e., pantry, closet, etc.) and existing master replaced with 8" speaker withcontrols (wall patching required). Wiring from existing master must be extended to IM-5000 location.

Page 13: RETRO FIT UPDATING GUIDE

13

IM-4406 SYSTEM COMPONENTS

IS-445D(Sable Brown)IS-445L(Biscuit)IS-445WH(Bright White)IS-445BL(Black)

5" Inside Speaker with Controls

IS-448D(Sable Brown)IS-448L(Biscuit)IS-448WH(Bright White)IS-448BL(Black)

8" Inside Speaker with Controls

IA-60D(Walnut)IA-60L(Biscuit)IA-60WH(Bright White)

Table-top or Surface-mountingFrame for 5" Inside Speaker

IA-6Wall Receptacle forIA-60 Series.IA-6C8' Cable for IA-6.

ISA-78L(Adobe White)ISA-78WH(Bright White)Use with InsideRemote Control.

8" Inside Speaker - Rectangular

IC-441WHW(Bright White)Surface-mounted.For use withISA-77, IS-79.

Outdoor Remote Control

IS-79Recessed.Use with OutdoorRemote Control.

8" Outdoor Speaker

ISA-77Surface-mounted.Use with OutdoorRemote Control.

8" Outdoor Speaker

IC-441WH(Bright White)For use with IS-76,ISA-78L & WH, IS-82

Inside Remote Control

IS-419WH(Bright White)IS-419AB(Antique Brass)IS-419PB(Polished Brass)Recessed.

5" Outdoor Speaker with Controls

IS-67D(Woodgrain/Brass)IS-67WH(White)Molded, recessed.

Door Speaker w/lighted pushbutton

IS-69AB(Antique Brass)IS-69PB(Polished Brass)IS-69WH(White)Classic Cast MetalRecessed.

Door Speaker with Lighted Pushbutton

ISA-63Molded,Surface-mounted.

Door Speaker - no pushbutton

ISB-64Molded,surface-mounted.

Door Speaker - unlighted pushbutton

IS-70AB(Antique Brass)IS-70PB(Polished Brass)IS-70WH(Bright White)Classic Cast MetalRecessed.

Door Speaker - no pushbutton

IS-82Use with InsideRemote Control.

5" Inside Speaker - Round

IS-76 (White)Use with InsideRemote Control.

8" Inside Speaker - Round

IA-70(Black)For recessed door speakers.

Surface-Mounting Frame

IS-449WH(Bright White)Surface-mounted.

5" Outdoor Speaker with Controls

NuTone

INS IDE/PAT IOTALK

D O O RTA L K

E N DC A L L

AM/FM/CD CONTROL

PRIVATEOFF ON

••

• •• • • • • • •

••

V O L U M E

••••

NuTone

NuTone

••

• •• • • • • • •

•• ••

NuTone

V O L U M E

INS IDE/PAT IOTALK

E N DC A L L

AM/FM/CDCONTROL

D O O RTA L K

PRIVATEO FF ON

••

NuTone

INS IDE/PAT IOTALK

D O O RTA L K

E N DC A L L

AM/FM/CDCONTROL

••

• •• • • • • • •

••• •

V O L U M E

PRIVATEOFF ON

NuTone

INS IDE/PAT IOTALK

D O O RTA L K

E N DC A L L

AM/FM/CDCONTROL

••

• •• • • • • • •

•• •

V O L U M E

PRIVATEOFF ON

•••

NuTone

NuTone

NuToneDoorSpeaker

NuTone

NuTone

NuTone

INS IDE/PAT IOTALK

D O O RTA L K

E N DC A L L

AM/FM/CDCONTROL

••

• •• • • • • • •

•• •

V O L U M E

PRIVATEOFF ON

•••

Page 14: RETRO FIT UPDATING GUIDE

14

IM-5000 SYSTEM COMPONENTS

IS-515L(Biscuit)IS-515WH(Bright White)

5" Inside Speaker with Controls

IS-518WH(Bright White)

8" Inside Speaker with Controls

IA-60L(Biscuit)IA-60WH(Bright White)

Table-top or Surface-mountingFrame for 5" Inside Speaker

IA-6Wall Receptacle for IA-60Series.IA-6C8' Cable for IA-6.

ISA-78L(Adobe White)ISA-78WH(Bright White)Use with InsideRemote Control.

8" Inside Speaker - Rectangular

IS-79Recessed.Use with OutdoorRemote Control.

8" Outdoor Speaker

ISA-77Surface-mounted.Use with OutdoorRemote Control.

8" Outdoor Speaker

IC-502L(Biscuit)IC-502WH(Bright White)For use with IS-76,ISA-78L & WH,IS-82

Inside Remote Control

IS-519(Biscuit)Recessed.

5" Outdoor Speaker with Controls

IS-67D(Woodgrain/Brass)IS-67WH(White)Molded, recessed

Door Speaker w/lighted pushbutton

IS-69AB(Antique Brass)IS-69PB(Polished Brass)IS-69WH(White)Classic Cast MetalRecessed.

Door Speaker with Lighted Pushbutton

ISA-63Molded,surface-mounted.

Door Speaker - no pushbutton

ISB-64Molded,surface-mounted.

Door Speaker - unlighted pushbutton

IS-70AB(Antique Brass)IS-70PB(Polished Brass)IS-70WH(Bright White)Classic Cast MetalRecessed.

Door Speaker - no pushbutton

IS-82Use with InsideRemote Control.

5" Inside Speaker - Round

IS-76 (White)Use with InsideRemote Control.

8" Inside Speaker - Round

IA-70(Black)For recessed door speakers.

Surface-Mounting Frame

IC-502LW(Biscuit)For use withISA-77, IS-79.

Outside Remote Control

NuTone

987

654

321

#0*

987

654

321

#0*NuTone

NuTone

987

654

321

#0*

NuTone

NuTone

987

654

321

#0*NuTone

NuTone

987

654

321

#0*

NuTone

NuTone

NuToneDoorSpeaker

NuTone

Page 15: RETRO FIT UPDATING GUIDE

15

OPTIONAL ACCESSORIESOPTIONAL ACCESSORIESIntercom Accessories

• Model IA-28 Chime Module: Plays eight (8) notes for front door,two (2) notes for rear door and one (1) note for a third door.

• Model IA-29 Deluxe Chime Module: Plays your choice of ten(10) melodies for front door, plus two (2) notes for rear door,one (1) note for a third door. Melodies include WestminsterChimes (8 notes and 4 notes), Anniversary Waltz, Beethoven'sFifth, Dixie, Greensleeves, Happy Birthday, Jingle Bells, Joy ToThe World, Mazel Tov, Oh Tannenbaum, and Star SpangledBanner.

• A NuTone Electronic Chime may also be used with the IM-4406Radio-Intercom and IM-5000 Intercom.

Cassette DeckModel CP-95

• Auto-reverse Cassette Deck recesses in the wall near theMaster Station. Lets you enjoy your favorite cassette tapes fromany speaker station.

• White finish with rounded corners. Installs in IR-90 Rough-inframe (sold separately).

• Controls include: direction, fast forward, rewind and eject.Includes storage compartment for four (4) tapes.

Refer to NuTone's catalog for complete product information.

IR-6Housing for built-in DoorSpeakers.

Cutout: 311⁄16" wide x 5" high.

ROUGH-INS

REMOTE SPEAKER UPDATE FRAME

IR-90Housing for CP-95Cassette Deck.

Cutout: 141⁄2" wide x 21⁄4" high.

IR-91Housing for IC-502, IC-441Remote Control.

Cutout: 61⁄8" wide x 31⁄4" high.

IR-9Housing for IS-79 WallCutout.

Cutout: 101⁄16" wide x 111⁄16" high.IR-50Housing for 5" Inside Speakers.

Cutout: 53⁄8" wide x 73⁄16" high.

IR-55Housing for IS-419 & IS-519Recessed Patio Speakers.

Cutout: 53⁄8" wide x 73⁄16" high.

IR-80Housing for 8"Inside Speakers.

Cutout: 85⁄8" wide x 101⁄4" high.

IR-105Housing for MasterStations. Includes (2)801T transformers andomni-directionalFM/AM antenna.

Cutout: 141⁄2" wide x 9" high.

IA-55WH (Bright White)IA-55L (Biscuit)To update 5" horizontal speakersfrom older systems to IS-445 andIS-515 Series.Dimensions:93⁄8" wide x 85⁄8" high.

IA-83WH (Bright White)IA-83L (Biscuit)To update larger speakers from oldersystems to IS-448 Series or IS-518 Series.NOTE: To ensure proper fit, the IA-83 willneed to be modified when used withIS-518 Series.Dimensions:121⁄4" wide x 131⁄2" high.

IR-70Housingfor IS-76RoundSpeaker.

Cutout: 103⁄4" diameter.

311/16"

5"

13/4"

25/8"

111/16"

101/16"

9"

3 / "3 8

4 / "121

7 3/16"

53/8"

73/16"

53/8" 11/4"

85/8" 11/2"

101/4"

31/4"

61/8"

21/4"141/2"

23/4"

23/4"

12 1/4"

12 3/8"

11/16"

10 3/4"

Page 16: RETRO FIT UPDATING GUIDE

4-WireRadio-IntercomUpdating Guide

NuTone model number IM-3204 may be used to update other 4-wire systems. Rough-inframes for the speakers and master units may differ in size depending on the manufacturer.Specific product information is available in NuTone’s full line catalog.

IM-3204 Series

Product specifications subject to change without notice.