reverse osmosis, commercialex 4040-d · terms the process is a “reverse process” ... reverse...

3
water treatment systems Reverse Osmosis, Commercialex 4040-D Contact Us Tel: +27-21-7885341/5342 | Fax: +27 (0)21 788 5386 | Email: [email protected] Web: www.aquamarinewater.co.za

Upload: lamdieu

Post on 24-Apr-2018

228 views

Category:

Documents


6 download

TRANSCRIPT

Page 1: Reverse Osmosis, Commercialex 4040-D · terms the process is a “reverse process” ... Reverse Osmosis unit ... All design information will be finalised based on feed

water treatment systemsReverse Osmosis, Commercialex 4040-D

Contact UsTel: +27-21-7885341/5342 | Fax: +27 (0)21 788 5386 | Email: [email protected]

Web: www.aquamarinewater.co.za

Page 2: Reverse Osmosis, Commercialex 4040-D · terms the process is a “reverse process” ... Reverse Osmosis unit ... All design information will be finalised based on feed

The Aquamarine range of Reverse Os-mosis systems is a comprehensive range of standard and customised products developed and manufactured in South Africa on the basis of the well-known process of Reverse Osmosis which has been under constant development since the first experimental systems were introduced in the 1950’s. In general terms the process is a “reverse process” based on the natural osmotic pressure difference between two salt solutions on either side of a membrane, in which mechanical pressure is applied to the side with higher salinity.

The membranes through which the salt passes at relatively high pressure are a vital part of the system, separating the fresh water from the “salty” or undesired water.

All Aquamarine systems use high qual-ity “thin film composite” spiral wound membranes housed in fibreglass rein-forced plastic or FRP pressure vessels. The operating processes are continually monitored and controlled by sophisti-cated PLC and microprocessor control-lers which will give immediate warning and possible shut down if any of the vital process parameters are not within ac-ceptable limits.

All systems have the option of a dosing pump to dose one of the many AQM membrane anti-scaling chemicals that will be customised as per the feed wa-ter conditions.

Reverse Osmosis unitModel : Commercialex RO4040-D

Contact UsTel: +27-21-7885341/5342 | Fax: +27 (0)21 788 5386| Email: [email protected]

Web: www.aquamarinewater.co.za

All pumps and instrumentation is of top quality which is vital to ensure reliability and long service life, with a minimum of maintenance required. The electrical and control logic is an inte-gral part of the system which will ensure long, trouble free operation of the sys-tem. The system includes all necessary instru-mentation including: • Flow meters for indication of fresh water and brine water outlet flows. • Glycerol filled pressure gauges for pressure indication. • Conductivity monitoring with warning and optional shut down for water quality management. • Pressure switches for protection against over and under pressure. • Float switches for system automa tion in relation to tank levels.

All frame work is epoxy coated mild steel and interconnecting pipework and fit-tings are either CL16 PVC or stainless steel for corrosion resistance.

Page 3: Reverse Osmosis, Commercialex 4040-D · terms the process is a “reverse process” ... Reverse Osmosis unit ... All design information will be finalised based on feed

Tel: +27-21-7885341/5342 | Fax: +27 (0)21 788 5386 Email: [email protected]: www.aquamarinewater.co.za

Basic System Features

• Frame: Stainless steel epoxy coated.• Pre filtration: 3 x 20” BB as per feed water conditions. • Anti-Scaling dosing: dosing pump for AQM membrane anti-scaling chemical dosing. • Inlet Solenoid valve: ¾” Brass.• Feed Pump (optional): Full plastic or Stainless steel centrifugal type booster pump. (1.25kW)• Fresh Water Flush pump: Stainless steel fresh water flush pump. (1.25kW)• High pressure pump: Multi Stage (sized as per feed water conditions)• Pressure Vessels: FRP pressure vessels / Stainless steel pressure vessels. • Membranes: Filmtec Membranes (model may vary depending on feed water conditions)• Pressure gauges: inlet and outlet pressure on pre-filters, system operating pressure, low pressure switch for monitoring of inlet pressure and high pressure switch for monitoring of system over pressure. • Flow meter: permeate, brine concentrate and brine recycle• Conductivity measurement: permeate measurement with over limit set point. • Electrical controls : OS3020 Microprocessor for system automation and water quality management. • Other: CIP connections for membrane cleaning. Optional cleaning rig is recommended.

Reverse Osmosis unitModel : Commercialex RO4040-D

Technical Data 4040/4 4040/6 4040/8 4040/10Permeate Flow Rate l/h 1000 1200 1500 2000Min Salt Rejection % 97 97 97 97Recovery % 75 75 75 75Operating Pressure bar 10-20bar 10-20bar 10-20bar 10-20barMembrane No 1 2 3 3Voltage V/Hz 220/380/50Hz 220/380/50Hz 220/380/50Hz 220/380/50HzFeed Water Connection Inch 1” Female 1” Female 1” FemalePermeate Water Connection mm ¾” Female ¾” Female ¾” Female ¾” FemaleBrine Water Connection mm ¾” Female ¾” Female ¾” Female ¾” FemaleDosage tank lts 100 100 100 100Min / Max inlet pressure bar 0.2/1 0.2/1 0.2/1 0.2/1Max ambient Temperature ºC 40 40 40 40Length mm 2400 2400 2400 2400Width mm 900 900 900 900Height mm 1600 1600 1600 1600

Weight approx. kg 200 220 240 240

All information shown on this data sheet is based on average conditions. All design information will be finalised based on feed water conditions and all system are subject to modifications.