reversing heavy duty motor starters p.€¦ · 2. plc—(assuming initiating starter coil via plc)...

8
Reversing Heavy Duty Motor Starters Melting Alloy Overload, Class 22 Selection r p. Ordering Instructions *• Use complete catalog number. Replace the I*) with letter Irom the coil table Dual voltage coils are wired on high voltage unless specified on order. + Order heater elements by code number at $9 each page 870. > For bimetal overload add "81 " to Catalog No to create a new base style. ("8" for single phase). Example: 22DP3ZA*81. Price same as melting alloy. *• Open vertical reversing starters are available in sizes 0-2'/2. Contact sales office for more information. *• Field Modification Kits page 116-120. Factory Modifications page 121-125. > Dimensions see pages 139-141. *• Wiring Diagrams see page 152. Coil Table 60Hz Voltage Letter 24 Separate Control J 120 Separate Control F 110-120/220 240 A 200-208 D 220-240 G 277 L 220-240/440-480® C 440-480 H 550-600 E For other voltages and frequencies see Factory Modifications page 124. 3 Phase, 3 Pole, Melting Alloy Overload (For Bimetal Overload see Ordering Instructions) Max Hp 200 Volts 1 '/;• 3 T/. 10 10 15 25 30 40 50 75 150 230 Volts 1 f. 3 77. 10 15 20 30 40 50 75 100 200 300 450 460 Volts 2 5 10 15 25 30 50 75 100 150 200 400 600 900 575 Volts 2 5 10 15 25 30 50 75 100 150 200 400 600 900 NEMA Size 00 0 1 2 3 4 5 5 7 H Hall Size _ IV. 2X. - 3V; 4X - Enclosure Open Type Catalog No 22BG32A" 22CP32A* 220P32A* 22EP32A* 22FP32A' 22GP32A- 22HP32A" 22IP32A' 22J632A* Price S 390. 462. 522 702. 990. 1314. 1644. 3534. 4014. NEMA1 .... -jl Purposa Catalog No 22BG32B* 22CP32B" 22DP32B* 22EP32B" 22FP32B" 22GP32B* 22HP32B* 22IP32B- 22JG32B* Price $ 414. 486. 558. 738. 1086. 1446. 1812. 3846. 4326. NEMA 4/4X Watertight, Dusttigh! Conos.uri Resistant 30-1 Sla.nless Steal® Catalog No Use Sue 0 22CP32W 22DP32W" 22EP32W* 22FP32W* 22GP32W" 22HP32W" 22IP32W 22JG32W* Price $ 762. 942. 1122. 1710. 2220. 2736. 5478. 5958, NEMA 7 & 9 NEMA 3 & 4 CIJSS -1 UK.TJP3 Catalog No t . 1 & G Price $ ESP1 00 Solid State Overload Standard. see page 71 NEMA 12 NEMA 3/3R ' Ina.f.linl Use Catalog No Use Size 0 22CP320* 22DP320* 22EP320* 22FP320' 22GP320* 22HP320* 22IP320" 22JG320* Price $ 594. 666. 846. 1266 1734. 2208. 4458. 4338. ESP100 Solid State Overload Standard See page 71. Single Phase, Melting Alloy Overload (For Bimetal Overload see Ordering Instructions) 3 Wire 2 Pole Mix Hp 115 Volts '/j 1 2 3 230 Volts 1 2 3 ^ NEMA Size 00 0 1 IP Enclosure Open Type Catalog No 22BG12A- 22CP12A" 22DP12A" 22EP12A- Price $ 363. 435. 496. 675. NEMA1 1 1: ji Purpose Catalog No 22BG12B* 22CP12B* 22DP12B' 22EP12B' Price $ 387. 459. 531. 711. NEMA 4/4X Watcrt.cjht. Duslliflht Cr.mnr.Kn Hesislant_ •)CM SMm'ov, Stoef*' Catalog No Use S.ffi 0 22CP12W* 22DP12W* 22EP12W Price $ 735. 915. 1095. NEMA 7 & 9 NEMA 3 & 4 i .iv. i -,-IMUPSC & n l :.i ,s II Gio.ips ^. f : & G Catalog No Use Sire 0 22CP12H' 22DP12H- 22EP12H' Price t 1566. 1644. 1824 NEMA 12 NEMA 3/3R lncl;l?*nfll ' J'-f Wpd'l'iiiyoMf Catalog No Use Sue 0 22CP120* 22DP120* 22EP120* Price $ 567. 639. 819. Single Phase, Melting Alloy Overload (For Bimetal Overload see Ordering Instructions) 4 Wire Repulsion Induction 3 Pole /) 1 2 3 I 2 3 5 00 n i 1P 22BP82A* 22CP82A" 22DP82A* 22EP82A" 375. 447. 507. 687. 22BP82B" 22CP82B* Z20P82B" 22EP82B- 399. 471. 543. 723. !lic Si?p(! 22CP82W 220P8ZW" 22EP82W 747. 927. 1107. llsi> SI.'P 0 22CP82H* 22DP82H- 22EP82H" 157S. 1659. 1839. Use Sire 0 22CP820" 22DP820* 22EP820" - 579. 651. 831. Single Phase, Melting Alloy Overload (For Bimetal Overload see Ordering Instructions) 4 Wire Phase One Line Direct 3 Pole <A 1 2 3 1 2 3 t; 00 0 1 IP 22BP92A" 22CP92A" 22DP92A" 22EP92A' 375. 447. 507. 687 22BP92B* 22CP92B* 22DP92B' 22EP92B" 399. 471. 543. 723. Use Sue 0 22CP92W 22DP92W 22EP92W" 747 927 1107. Use Sire 0 22CP92H* 22DP92H' 22EP92H" 1578 1659 1839. Use Sue 0 22CP920* 22DP920' 22EP920' 579. 651. 831 Single Phase, Melting Alloy Overload (For Bimetal Overload see Ordering Instructions) 4 Wire Split Phase All Leads Broken 4 Pole /3 T 2 3 1 2 •) 'j 00 0 1 - n 22BP52A* 22CPS2A* 22DP52A* 22EP52A" 495. 567. 645. 825. 22BP52B" 22CP52B" 22DP52B* 22EP52B' 519 591 669. 849. Use S-/P 0 22CPS2W 22DP52W* 22EP52W 867. 1053 1233. HwSi7pn 22CP52H' 22DP52H' 22EP52H* - 1710. 1785. 1965. Use Sw 0 22CP520" 22DP520' 22EP520* 669. 777. 957. l Dual Voltage NAon Size 00. i'For NEMA 4X fiberglass enclosure change 7th character of Cat No lo F. Example: 22CP32F. Price addition see page 123. Available through si?ft 4. JNEMA 12 may be field modified for NEMA3/3R. see page 119. Discount Schedule AC-10 (FURN) Siemens & Furnas Control Products

Upload: others

Post on 14-Oct-2020

2 views

Category:

Documents


0 download

TRANSCRIPT

Page 1: Reversing Heavy Duty Motor Starters p.€¦ · 2. PLC—(assuming initiating starter coil via PLC) Timers and counters can be used to determine time between restarts and maximum number

Reversing Heavy Duty Motor StartersMelting Alloy Overload, Class 22

Selection

rp. Ordering Instructions

*• Use complete catalog number. Replace the I*) with letter Irom the coil table

Dual voltage coils are wired on high voltage unless specified on order.+ Order heater elements by code number at $9 each page 870.> For bimetal overload add "81 " to Catalog No to create a new base style.

("8" for single phase). Example: 22DP3ZA*81. Price same as melting alloy.*• Open vertical reversing starters are available in sizes 0-2'/2. Contact sales

office for more information.*• Field Modification Kits page 116-120. Factory Modifications page 121-125 .> Dimensions see pages 139-141.*• Wiring Diagrams see page 152.

Coil Table

60Hz Voltage Letter24 Separate Control J120 Separate Control F110-120/220 240 A200-208 D220-240 G277 L220-240/440-480® C440-480 H550-600 EFor other voltages and frequenciessee Factory Modifications page 124.

3 Phase, 3 Pole, Melting Alloy Overload (For Bimetal Overload see Ordering Instructions)

Max Hp

200Volts

1 '/;•3T/.

1 01 01 52530405075

150—

230Volts

1 f.377.

101 52030405075

100200300450

460Volts

25

1 01 525305075

100150200400600900

575Volts

25

1 01 525305075

100150200400600900

NEMASize

0001

2—3

—4

—557H

HallSize

_—IV.—2X.-3V;

—4 X—-—

EnclosureOpen Type

Catalog No

22BG32A"22CP32A*220P32A*22EP32A*22FP32A'22GP32A-22HP32A"22IP32A'22J632A*

Price S

390.462.522702.990.

1314 .1644.3534.4014.

NEMA1.... • - j l Purposa

Catalog No

22BG32B*22CP32B"22DP32B*22EP32B"22FP32B"22GP32B*22HP32B*22IP32B-22JG32B*

Price $

414.486.558.738.

1086.1446.1812 .3846.4326.

NEMA 4/4XWatertight, Dusttigh!Conos.uri Resistant30-1 Sla.nless Steal®Catalog No

Use Sue 022CP32W22DP32W"22EP32W*22FP32W*22GP32W"22HP32W"22IP32W22JG32W*

Price $—

762.942.

1122.1710.2220.2736.5478.5958,

NEMA 7 & 9NEMA 3 & 4

CIJSS -1 UK.TJP3

Catalog Not . 1 & G

Price $

ESP1 00 Solid StateOverload Standard.see page 71

NEMA 12NEMA 3/3R 'Ina.f.linl Use

Catalog No

Use Size 022CP320*22DP320*22EP320*22FP320'22GP320*22HP320*22IP320"22JG320*

Price $

594.666.846.

12661734.2208.4458.4338.

ESP100 Solid State Overload StandardSee page 71.

Single Phase, Melting Alloy Overload (For Bimetal Overload see Ordering Instructions) 3 Wire 2 Pole

Mix Hp

115Volts

'/j123

230Volts

123^

NEMASize

0001IP

Enclosure

Open Type

Catalog No

22BG12A-22CP12A"22DP12A"22EP12A-

Price $

363.435.496.675.

NEMA11 1 : ji Purpose

Catalog No

22BG12B*22CP12B*22DP12B'22EP12B'

Price $

387.459.531.7 1 1 .

NEMA 4/4XWatcrt.cjht. DuslliflhtCr.mnr.Kn Hesislant_•)CM SMm'ov, Stoef*'

Catalog No

Use S.ffi 022CP12W*22DP12W*22EP12W

Price $

735.915.

1095.

NEMA 7 & 9NEMA 3 & 4i .iv. i -,-IMUPSC & nl :.i ,s II Gio.ips ^. f: & G

Catalog No

Use Sire 022CP12H'22DP12H-22EP12H'

Price t

1566.1644.1824

NEMA 12NEMA 3/3Rlncl;l?*nfll ' J'-fWpd'l'iiiyoMf

Catalog No

Use Sue 022CP120*22DP120*22EP120*

Price $

567.639.819.

Single Phase, Melting Alloy Overload (For Bimetal Overload see Ordering Instructions)4 Wire Repulsion Induction 3 Pole

/)123

I235

00ni1P

22BP82A*22CP82A"22DP82A*22EP82A"

375.447.507.687.

22BP82B"22CP82B*Z20P82B"22EP82B-

399.471.543.723.

!lic Si?p(!22CP82W220P8ZW"22EP82W

747.927.

1107.

llsi> SI.'P 022CP82H*22DP82H-22EP82H"

—157S.1659.1839.

Use Sire 022CP820"22DP820*22EP820"

-579.651.831.

Single Phase, Melting Alloy Overload (For Bimetal Overload see Ordering Instruct ions)4 Wire Phase One Line Direct 3 Pole

<A123

123t;

0001IP

22BP92A"22CP92A"22DP92A"22EP92A'

375.447.507.687

22BP92B*22CP92B*22DP92B'22EP92B"

399.471.543.723.

Use Sue 022CP92W22DP92W22EP92W"

—747927

1107.

Use Sire 022CP92H*22DP92H'22EP92H"

157816591839.

Use Sue 022CP920*22DP920'22EP920'

—579.651.831

Single Phase, Melting Alloy Overload (For Bimetal Overload see Ordering Instructions)4 Wire Split Phase All Leads Broken 4 Pole

/3

T23

12•)'j

0001

- n

22BP52A*22CPS2A*22DP52A*22EP52A"

495.567.645.825.

22BP52B"22CP52B"22DP52B*22EP52B'

519591669.849.

Use S-/P 022CPS2W22DP52W*22EP52W

—867.

10531233.

H w S i 7 p n22CP52H'22DP52H'22EP52H*

-1710.1785.1965.

Use Sw 022CP520"22DP520'22EP520*

—669.777.957.

l Dual Voltage NA on Size 00. i'For NEMA 4X fiberglass enclosure change 7th characterof Cat No lo F. Example: 22CP32F. Price addition seepage 123. Available through si?ft 4.

JNEMA 12 may be field modified for NEMA3/3R.see page 1 1 9 .

Discount Schedule AC-10 (FURN)Siemens & Furnas Control Products

Page 2: Reversing Heavy Duty Motor Starters p.€¦ · 2. PLC—(assuming initiating starter coil via PLC) Timers and counters can be used to determine time between restarts and maximum number

General InformationNorth American Approvals

General

INSTALLATION CONSIDERATIONSThe control products described in this cata-log have been designed, tested and manu-factured in accordance with a wide variety ofstandards including but not limited to thoseissued by UL, CSA, NEMA and IEC. These .standards typically apply to the control prod-uct as a component and not the installationor use of the product. It is the responsibilityof the end user of the control product tomake sure each installation complies with allof the applicable safety requirements, laws,regulations, codes and standards (someexamples of which are the N.E.C., the C.E.C.

and OSHA regulations). Note that localauthorities may impose further, jurisdictionover each installation. When in doubt, con-sult with the local inspection authorities.Unless otherwise specified, the control prod-ucts described in this catalog are designedto operate under "usual service conditions"as defined in NEMA Standards Publication—Part ICS 1 - 1 0 8 . Open type devices areintended for installation in enclosures thatprovide environmental protection as neededfor the specific application. See page 14 fordefinitions of the various enclosure types.

PERFORMANCE DATAWhere given in this catalog, performancedata should only be used as a guide to deter-mine the suitability of the product for anapplication. The data may be the result ofaccelerated testing or elevated stress levelsunder controlled conditions. The user musttake care in correlating this data to actualapplication or service conditions.UL and CSA—File Numbers and GuideCard Numbers

Most control equipment listed in this catalog isdesigned, manufactured and tested in accor-dance with the relevant UL and CSA standardsas listed in the table below.

Siemens Brand DevicesDescription

3TH2Control Relays 3TH3

3TH8Solid-state timersAC contactors, DC contactorsReversing StartersOverload relaysTerminal blocksManual Motor Controller 3VUCam Switch 3LB, 3LCStarters, Combination Starters

Push buttons

Lighting and Heating ContactorsMechanical Limit Switches

International StyleNorth American Style

Fast Rus Components/KitsModular Motor Controllers Type EModular Motor Controllers —

Group InstallationUS Series StarterFraction Hp Starters, SMR MMS

@Guide No File No

Class 3211 LR1273°LlassAm LR 50487

Class 3 2 1 1 LR 12730Class 3 2 1 1 LR 12730Class 321 1 LR 38590Class 3 2 1 1 LR 12730Class 3 2 1 1 LR50181Class 321 1 LR 50487Class 3 2 1 1 LR 12730Class 3 2 1 1 LR 38590

Class 3211 LR 12730

Class 3231 LR 38590

Class 321 1 LR 50487Class 3211 LR 68551— —— —

Class 3211 LR 50487

Class 3211 LR 38590— —

®Guide No File No

NKCR E 44653

NKCR E 44653NLDX E 3 1 5 1 9NLDX E 32529NKCR E 44653— —NLVR E 47705NLRV E 47705NLDX E 32529

NCXR ™

NRNT E 60310

NKCR E 44653NKCR E 4751 2NMTR E 155959NKJH E 156943

NLRV E 47705

NLDX E 32529— —

*1Guide No File No

NKCR2 E 44653

— —NLDX2 E 3 1 5 1 9— —NKCR2 E 44653XCFR2 E 80027— —— —— —

— -

— —

NKCR2 E 44653

NMTR2 E 160776— —

— —

— —NLRV2 E 80332

Furnas Brand DevicesClass

1 1 , 1 2Danms Switches14,22,30,40,43Starters and Contactors1 7 , 1 8 , 2 5 , 2 6 , 3 2Combination Starters36,37Reduced Voltage Starters83, 84, 85, 87, 88Pump Control Panels50Standard Duty Pilot Devices51Hazardous Location Pilot Devices5230 mm Pilot Devices1 6 , 4 1 . 4 2 , 4 5Definite Purpose Controls46,47Relays48, 948, 958Overload Relays49Field KitsClass 56Fast SwitchClass 53Master SwitchClass 69Pressure Switch

eGuide No File No

Class 3 2 1 1 LR6535

Class 3 2 1 1 LR6535

Class 3211 LR6535

Class 3211 LR6535

Class 3 2 1 1 LR6535

Class 3211 LR6535

Class 3218 LR 23889

Class 3211 LR6535

Class 321 1 LR 6535

Class 3 2 1 1 LR6535

Class 3 2 1 1 LR6535

Class 3211 ELR535

Class 3211 LR6535

Class 3211 LR6535

Class 321 1 LR 6535

®Guide No File No

NLRV E 10590

NLDX E 14900

NKJH E 185287

NLDX E 14900

NKJH E 185287

NKCR E 22655

NOW E 39935

NKCR E 22655

— -

NKCR E 22655

NKCR E 22655

NLDX E 14900

NLRV E 10590

NKCR E 22655

NKPZ E 14861

>MGuide No File No

NLRV2 E 10590

NLDX2 E 14900

— —

NLDX2 E 14900

— —

— —

— —

NKCR2 E 22655

NLDX2 E 14900

NKCR2 E 22655

NKCR2 E 22655

NLDX2 E 14900

— —

_ _

NKPZ2 E 14861

Siemens & Furnas Control Products

Page 3: Reversing Heavy Duty Motor Starters p.€¦ · 2. PLC—(assuming initiating starter coil via PLC) Timers and counters can be used to determine time between restarts and maximum number

Heavy Duty StartersSize 0-4 Starter Features, Application

General

Size 0-13/«ESP100 Solid State Starter

ESP100 Solid State Overload RelaysThese standard features of the ESP100provide Extra Starter Performance.• True phase loss protection; trips

within 3 seconds.• High accuracy trip curves; ± 2%

repeat trip accuracy.• Ease of use. Mount, wire, and set FLA• Overload is self protected against

short circuits.• Overload is self powered and

requires no hard wiring or separatepower source.

• Simple, versatile adjustment; mini-mum of 2:1 FLA adjustment range.(4:1 in lower FLA ranges.)

• Heaterless construction minimizesenergy costs and the costs of cabinetventilation or cooling.

• Class 20 protection is standard. Class10 and 30 protection are available.

• Provides motor protection for50/60 Hertz.

ESP1QO FLA Adjustment Dial—Set the adjustment dial on the overload to theFLA of the motor.

ESP100 starters combine the ruggedcharacteristics of a NEMA rated con-tactor with a solid state overload whichprovides phase loss protection. Itoffers the industrial user greater pro-tection and added life for motors inheavy duty applications. The inherentbenefits of the ESP100 result in costsavings as well.Self-Reset VersionThe self-reset starter is ideal forcranes, hoists, and other applicationswhere the controls are mounted in aremote location that may be difficult toaccess. The NC overload contactopens for a short duration (50-75msec) on an overload or phase losscondition The unit provided can beapplied in one of three ways:1. Three wire control circuit usingFurnas Size 0-4 contactor. The self-reset overload can be retrofitted andapplied in a three wire control applica-tion as a remote reset overload with-out additional components or wiring.2. PLC—(assuming initiating starter coilvia PLC) Timers and counters can beused to determine time betweenrestarts and maximum number ofrestarts.3. Use NC overload contact to drop outa control relay. See page 475 for wiringdiagrams.

Figure 1MELTING AtLO»HEATERSCOKRESKWOWGTOOtAl SEATING

MJOO.ECLICKSOMOlAl

Typical Solid-State OverloadAdjustment Dial Markings

Each overload is precisely calibrated andlabels are individually laser printed andthen custom applied for each particularcalibration.

Typical Number of Heater ElementsNeeded for Alloy Overloads

• No need for heater coilselection or installation.

• No heater elements to stock.• More precision.

Size 0-1%Melting Alloy Starter

Melting Alloy starters are standardTogether with the proper heater ele-ments, these starters help to provide protection to motor windings from harmfulcurrents. These currents damage themotor winding through overtemperatui'The conditions are often caused by ovcloading the motor, sustained low voltac;.or stalled rotor.Melting Alloy overloads include a tripindicator and manual test feature. Anisolated NO or NC contact is available.

a(S

BO

Size 0 -1%Bimetal Starter

Bimetal starters, together with theproper heater elements, help to provideprotection to motor windings fromharmful currents. These currents dam-age the motor winding through Movertemperature. The conditions areoften caused by overloading the motor,sustained low voltage, or stalled rotor.Bimetal overloads are convertible frommanual to automatic reset. Heaters canbe selected as standard class 20 orquick trip class 10. Starters can be fac-tory ordered with a NO/NC (SPOT)Form C contact.

Siemens & Furnas Contro l Products

Page 4: Reversing Heavy Duty Motor Starters p.€¦ · 2. PLC—(assuming initiating starter coil via PLC) Timers and counters can be used to determine time between restarts and maximum number

Magnetic Motor ControlsNEMA Catalog Numbering System

General

Class

17 —

.18 —

25 —

26 —

Combination Starter Size(Non husible, t-usible)Combination Starter C — 0 Model

ESP1 JOCurrent Range®

Three PhaseA —B —CD —p_ _

(Circuit Breaker) ? 1 1- —Reversing E ~ 1 / < & 1 P P - Innova Plus G_Combination Starte'r F — 2 size 0-4 H _(Non Fusible, Fusible) G - 2V5 S - ESP100 size 0-3* j _Reversing H - 3 T - ESP100 size 4-8 K _Combination Starter ' ~ 3/; R - ESP10° Self-Reset L _(Circuit Breaker) J ~ *, Slze °^5 M —

K — Vh c

M — 6 92 — Standard Width X —N — 7 82 — Extra Wide V —p ~ 8 72 — Horizontal Z —

Compact

B — NEMA 1F — NEMA 4XN — NEMA 12

V13/«-33-62l*-1 0

13-2720-4022-4530-6045-9057-11567-135100-100-

2 1 0no

200-540420-820420-1220

|

-IP rntta®

Horsepower Rating

A — /$,BCD -E -FG -HJK -1 -MNPRSTVWX

— 1,- 3,

'/5.1,1,3, 35,5, 5

- 3, 3, 7'A, 7'/5- 7V?, 7/4, 10, 10- 5, 5, 15, 15— 10, 10,—.—— 7'/5, 10,- 10

K

20,20, 15, 25, 25, 15, 30, 30

- 15, 20, — , —- — , — , 30, 30— 25, 30, 50, 50— 30, 40, 75, 75- 40, 50,- 50, 75,- 50,75,— 75, 100

100, 100150, 150150, 200?no _

— 100, 125, 250, 300- 150, 200, 400, 400

N —W —

Convertible to 3/3RNEMA 4/4X Stainless

Class

14 — Across the Line NEMAMotor Starter

22 — Reversing NEMA MotorStarter

40 — Across the Line NEMAMagnetic Contactor

43 — Reversing NEMA MagneticContactor

ize ————————————————————

— 00 Model— 0_ ^ P — Innova Plus- I3/, &1P sizeO-3'/;

——— I ———

Power Poles ——————

ESP 100Current Range® '

Three Phase 'A — Vt-1B — 3/:-3C — 3-6 ,D — 2^10E — 9-18F — 13-27G — 20-40H — 22-45J — 30-60

'Mot Control Circuit

! — suitable for3 wire control(NO aux.contact incl.}

> — 2 wire control(NO aux.contact notincl.)

1 — 2 power poles, 1 phase K — 45-90— 2 G ~ Compact size 00 3 _ 3 power po es, 3 phase L — 57-115

•}'/- Innova Plus size 4 .... . M R7 115~ Q cqpinn. - o n t'/ Additional Options M b/-Ubo o — tbriuu s ze u— o/? r c mn ?in~ T cspinn •=;,„ 4_R 1 Phase Reversing b — 100-210— 3// T — ESP100 size 4-8 » u _ 100-270_ 4 R — ESP100 Self-Reset Lclass •" & 4J on y) v ,nn_c/in_ 4i size 0-5

1 — 6— 7— 8

b — 4 power po es " *•"" -™4 wire split phase all ' ~ 420-820eads broken Z - 420-1220

8 — 3 power poles Single Phase®

Enclosure Type

Coil

A®— 110-120V/220-240V@60Hz1 10V/190-220V@50Hz

C®— 220-240V/440-480V@60Hz1 90-220V/380-440V@50Hz

D — 200-208V@60HzE — 550-600V@60Hz

650V@50HzF — 120V@60Hz

110V@50HzG — 220-240V@60Hz

190-220V@50HzH — 440-480V@60Hz

380-440V@50HzJ*— 24V@60Hz

24V@50HzL — 277V@60Hz

240V@50HzA — OpenB — NEMA 1D — NEMA 3 (sizes 0-1 3/<)F — NEMA 4XH — NEMA 7 & 9, boltedO — NEMA 12 Convertible to 3/3RW — NEMA 4/4X Stainless Steel

4 wire split repulsion fl , 1induction

9 — 3 power poles4 wire split phase cine direct

B 3/ o— /a—JD — 2V5-10ne - -t —— D-1D

1

Model

Class Size ESP 100 Current Range® Type Line Volts Enclosure Type Coil Disconnect Type®

36 — Non Combo C — 0 S — ESP100 TReduced D — 1 size 0-4 PVoltage E — 1% T — ESP100 OStarter F — 2

37 — Combo G — 2'/2Reduced H — 3Voltage I — 3'/2Starter J — 4

K —— 41/4

L — 5M— 6N— 7P — 8

size 4'/2-8C

— Auto XFMR 2 —— Part Wind. 3 —— Wye Delta 4 —

Open Trans. 5 —— Wye Delta 6 —

Closed Trans.

230 A — Open D — Non Fused Disc.380 B — NEMA 1 F — Fusible Disc.460 W — NEMA 4/4X P — MCP575 Stainless Steel T — Thermal Magnetic200/208 O — NEMA 12

©Single phase ESP100 available on Class 14 Startersonly.

®Not used on Class 17, 25 or with ESP100 versions.®Not available on sizes 4V2-8.

®For Class 37 only.©Position used for ESP100 only.

52Siemens & Furnas Control Products

Page 5: Reversing Heavy Duty Motor Starters p.€¦ · 2. PLC—(assuming initiating starter coil via PLC) Timers and counters can be used to determine time between restarts and maximum number

Heavy Duty Controls ModificationsFactory Modifications__________________

Selection

Ordering Instructions

*• Catalog Number Suffixes indicate num-bers or letters added to the end of acatalog number. Example: 14DP32BAbecomes 14DP32BAA1.

*• Multiple Modification Suffixes are addedin numerical, alphabetical sequence.

Overload OptionsOverload Relay Classes 14, 17, 18, 22, 25, 26, 36, 37

DescriptionAmbientCompensatedBimetalBimetal Overload Locked in Position®Variable Trip Locked in 100% PositionReset Locked in Manual PositionVariable Trip and Reset Locked

ESP1 00 Trip Class Option

Description

ESP1 00 Single Phase

TripClass

Class 10 or 20(K or E heaters)

Class 10Class 30

Phase

1 Phase

Phase

3 Phase

1 Phase

3 Phase

ContactsNCMO & NC, SPOTNC

NCNC

Available OverloadAmp Ranges

0.25-1.00.75-3.02.5-105-1 6

Catalog NoSuffix81918

SIS2S5153

Controller Size — Price Addition $00-13ANC36.NC

2,2%NC36.NC

3, 3VzNC

4NC

Add $3 to PriceAdd $3 to PriceAdd $6 to PriceNCNC

LetterDesignation (5th Char)

ABDE

NCNCCatalog NoSuffix

X359U

NCNC

NCNC

Controller Size — Price Addition $00-1

NC

Overload Relay Classes 30, 32, 83, 84

DescriptionAmbientCompensatedBimetalBimetal Overload Locked in Position®Variable Trip Locked in 100% PositionReset Locked in Manual PositionVariable Trip and Reset LockedMelting Alloy

TripClass

Class 10 or 20

Class 84

Phase

3 Phase

1 Phase

1 Phase

ContactsNCNO & NC, SPOTNC

NC

Catalog NoSuffix81918

S1S2SX359U

Controller Size — Price Addition $00-11/.NC72.NC

2, 2%NC72.NC

3, 3%NC

4NC

Add $3 to PriceAdd $3 to PriceAdd $6 to PriceNC NC NC —

Overload Options for NEMA Size 00 (14 BG, 22 BG)Overload Relay

Description

AmbientCompensatedBimetal

Phase

1 Phase NC3 Phase NCNC & NO (SPOT)

Catalog NoSuffix

88191

Class

PriceAddition $

NCNC30.

NEMA 4X Fiberglass Enclosure Options®

Description

Non-Combination

Catalog NoChange

7th Char to F, 8th Char for ESP1 00

Class

1 4 , 2 2 , 4 0 , 4 3

Controller Size — Price Addition $00-1%

228.

2, 2%

492.

3, 3'/2

780.

4

1065.

Description

Non-CombinationCombination Circuit BreakerCombination Fused Disconnect SwitchCombination Non-Fused Disconnect Switch

Catalog NoChange

7th Char to F, 9th Char for ESP1007th Char to F, 9th Char for ESP1007th Char to F, 9th Char for ESP1007th Char to F, 9th Char for ESP100

Class

30

32

32

32

Controller Size — Price Addition $0

188.225.

378.

339.

1-1%

192.

242.

387.

350.

2, 2'A

210.

252.

560.

490.

3, 3'A

375.

777.

854.

756.

4

869.

1534.

1641.

1454.

©Minimum order and release, 50 units.©Price addition to open style pricing.

Discount Schedule AC-10 (FURN)Siemens & Furnas Control Products

Page 6: Reversing Heavy Duty Motor Starters p.€¦ · 2. PLC—(assuming initiating starter coil via PLC) Timers and counters can be used to determine time between restarts and maximum number

Heavy Duty Controls ModificationsFactory Modifications__________________

Selection

Ordering Instructions

> Catalog Number Suffixes indicate numbers or letters added to the end of a catalog number.Example: 14DP32BA becomes 14DP32BAA1.

>• Multiple Modification Suffixes are added in numerical, alphabetical sequence.

Coil Options

DescriptionAC Coil®

Volts 60HZ

24 Separate Control120 Separate Control110-120/220-240200-208220-240277220-240/440-480440-480550-600

Volts 50HZ241 1 0110/190-220

190-220240190-220/380-440380-440550

DC Coil

DC Coil and AC-DC Rectifier

LabelColorBlackBlackBlueOrangeBlueOrangeRedRedOrange12V24V32V48V125V250V120V AC240V AC

Catalog NoChange

8th char9th charesmr9th char9th char esfW10th char12th charBSPB"11th char12th char esw»13th charesMW'Coil LetterJTADGLCHERSTUVwVYWY

Class

14,17.22,25,36, 37, 40, 43

18,26

30

3232 Breaker32 Disconnect

All

All

AllInnova

EnclosureType

All

All

All

Controller Size — Price Addition $

0-1V.

NC

102.

228.294.

2, 2%

NC

102.

228.294.

3, 3%

NC

198.

240.306.

4

NC

264.

240.390.

4'/2. 5 6 7 8

Dual voltage coilsnot available.

NC

330.

456.522.

NC

NC

NC

Control Options

DescriptionSurge Suppression for 120V AC CoilDisconnect Switch Interlock 2 NO/2 NCMotor Circuit run/MrProtector Interlock '

DPOT

SPDT

Circuit Breaker Shunt TripCircuit Breaker Undervoltage TripCircuit Breaker Alarm Switch Trip1 Phase Combination StarterIsolated Alarm Contact on Melting Alloy OverloadGround Lug - 1 ConductorBlown Fuse Indicator LightsControl Circuit Fuse and Holder(Transformer Primary Fusing)Control Circuit Fused DisconnectInternally Operated

1 Fuse2 Fuses

Control Circuit Circuit BreakerInternally OperatedConvenience Receptacle Mounted onSide of EnclosureDrip HoodSpace HeaterSpace Heater with Thermostat

Catalog NoSuffixSSGY

GY

L6L7L8X359UL9L10L11F1F2

F3

F4

RE

DPSHST

Class

17,25,32 36, 37, 8718.26,32,36, 37, 87AllAllAll1 7 , 1 8AllAllAll

All

All

All

All

All

EnclosureTypeAll1 . 3 , 4 , 1 2

1 , 3 . 4 , 1 2

AllAllAllAllAllAllAll

1 , 3 , 4 , 1 2

1 , 3 , 4 , 1 2

1 , 3 , 4 , 1 2

1 , 1 2

11,3,4.121 , 3 , 4 , 1 2

Controller Size — Price Addition $

0-1 V.54.88.

174.

495.495.495.NC75.12.

300.132.132.

324.

522.

120.

108.420.450.

2.2%

54.88.

174.

495.495.495.NC75.12.

300.132.132.

324.

522.

120.

132.420.450.

3, y/i54.88.

174.

495.495.495.NC75.12.

300.132.132.

324.

522.

120.

396.420.450.

4—88.

174.

495.495.495.—75.12.

300.132.132.

324.

522.

120.

396.420.450.

4%. 5

66.174.

174.

495.495.495.—75.12.

300.132.132.

324.

522.

120.

528.420.450.

6

66.174.

174.

495.495.495.—75.12.

300.——

324.

522.

120

720.420.450.

7

66.174.

174.

495.495.495.—75.12.

300.——

324.

522

120.

720.420.450.

8

66.174.

174.

495.495.495.—75.12.

300.——

324.

522

120.

720.420.450.

DescriptionReversing in one speed only 2 speed 1 windingReversing in one speed only 2 speed 2 windingReversing in both speeds 2 speed 1 windingReversing in both speeds 2 speed 2 winding

Catalog NoSuffixX439UX440UX441UX442U

ProductClass

30,32

Controller Size — Price Addition $

0720.696.972.

1080.

1

774.748.

1056.1164.

I3/.

877.894.

1418.1654.

2

1032.1052.1668.1946.

2%1275.1316.2111 .2377.

3

1500.1548.2484.2796.

3%

1721.1776.3274.3244.

4 5

2025.2090.3852.3816.

©Voltages and frequencies not listed, contact salesiffice.

Discount Schedule AC-10 (FURN)Siemens & Furnas Control Products

Page 7: Reversing Heavy Duty Motor Starters p.€¦ · 2. PLC—(assuming initiating starter coil via PLC) Timers and counters can be used to determine time between restarts and maximum number

Heavy Duty Contactors and StartersAuxiliary Contact Configurations_____________

Technical

Heavy Duty Non-Reversing Contactor And Starter AuxiliaryContact Configurations

Heavy Duty Reversing Contactor And AuxiliaryContact Configurations

Size

0-1 3/j

2-4if A. 5

6,7

8

Standard Contactsat No Additional Price

1-NO

1-NO2-NO and 2-NC

1-NO and 1-NC

1-NO

Extra Contacts in AdditionTo Standard Contactsfor an Additional Price®®

Left Hand Side

2-NO or NC

1-NO or NC1-NO and 1-NC

1-NO and 1-NC

Right Hand Side

2-NO or NC

2-NO or NC1-NO and 1-NC

2-NO and 2-NC

4-NO and 4-NC

Size

0-1 3/< (Left Com.)0-1 3/< (Right Com.)2-44/2, 5 (Left Cont)4'/>, 5 (Right Cont.)6, 7 (Left Cont.)6, 7 (Right Cont.)8

Standard Contacts®Per Contactorat No Additional Price

1-NO and 1-NC1-NO and 1-NC1-NO and 1-NC2-NO and 2-NC2-NO and 2-NC1-NO and 1-NC1-NO and 1-NC2-NO and 1-NC

Extra Contacts Per Contactorin Addition to Standard Contactsfor an Additional Price®®

Left Hand Side

2-NO or NC1-NO or NC1-NO or NC1-NO and 1-NC

1-NO and 1-NC2-NO and 2-NC

Right Hand Side

1-NO or NC2-NO or NC1-NO or NC

1-NO and 1-NC2-NO and 2-NC1-NO and 1-NC3-NO and 3-NC

Non-Reversing

Size 0-13/.

IiI

I I I II 1 I I

1I

O ——

II ——

O

Size 2-4

Size 4/2, 5

" I I ISize 6-7

Reversing®, Two Speed Two Winding®

Size

1

0— H

I ——

p

?I i :i ;t iuI

• FI

-X-i1I

T i l lnniiii

Size 2-4

II

6' II

•••• 0

I I Iinii;i

jii

I I II H

iii4,

Size 4/!f 5

Size 6-7

Size 8

X

©If extra auxiliary contacts are required in addition tothe maximum available, add a control relay to theenclosed starter from the factory modifications.

©See page 117 or 122 for price on additional auxiliarycontacts. Extra contacts shown above are shaded.

©For each contactor, 1-NC contact used for standardelectrical interlocking scheme and 1-NO for seal incontact.

®Two Speed One Winding Controls require extra powerpoles or third contactor. Configurations will vary.

Siemens & Furnas Control Products

Page 8: Reversing Heavy Duty Motor Starters p.€¦ · 2. PLC—(assuming initiating starter coil via PLC) Timers and counters can be used to determine time between restarts and maximum number

Heavy Duty Contactors and StartersControl Ratings______________________

Technical

Max HP Plugging and JoggingRatings shown are for applicationsrequiring repeated interruptions ofstalled motor current or repeated clos-ing of high transient currents encoun-tered in rapid motor reversal, involvingmore than five openings or closings perminute and more than ten in a tenminute period, such as plug stop,plug reverse or jogging duty. Ratingsapply to single speed and multi speedcontrollers.Continuous Amp Ranting, Service LimitThe service limit current represents themaximum RMS current, in amperes,which the controller may be expectedto carry for protracted periods in normalservice. At service limit current ratings,temperature rises may exceed thoseobtained by testing the controller at itscontinuous current rating. The trip cur-rent of overload relays or other motorprotective devices shall not exceedthe service limit current ratings of thecontroller.Ballast Type, Tungsten and OtherDischarge Type Lighting LoadsThe characteristics of ballast type lampsare such that it is not necessary toderate Class 40 contactors below theirnormal continuous current rating. Class

NEMA Electrical/Mechanical Ratings

40 contactors may also be used for con-trolling tungsten and other dischargetype lighting loads, Class 40 contactorsare specifically designed for such loadsand are applied at their full rating aslisted in the Class 40 section.Resistance Heating LoadsRatings apply to Class 40 contactorswhich are employed to switch the loadat the utilization voltage of the resis-tance heating or light producing ele-ment with a duty which requirescontinuous operation of not more thanfive openings per minute.Capacitor Switching KVA RatingWhen discharged, a capacitor hasessentially zero impedance. For repeti-tive switching by a contactor, sufficientimpedance should be connected inseries to limit inrush current to notmore than 6 times the contactor ratedcontinuous current. In many installa-tions, the impedance of connectingconductors may be sufficient for thepurpose. When switching to connectadditional banks, the banks already onthe line may be charged and can supplyadditional available short circuit currentwhich should be considered whenselecting impedance to limit thecurrent.

The ratings for capacitor switchingabove assume the following maximumavailable fault currents:

Size 2-3: 5,000 AmpRMS Sym

Size 31/2-5: 10,000 AmpRMS Sym

Size 6: 18,000 AmpRMS Sym

If available fault current is greater thanthese values, connect sufficient imped-ance in series as noted in the previousparagraph.The motor ratings in the table below areNEMA standard ratings and apply onlywhen the code letter of the motor isthe same as or occurs earlier in thealphabet than is shown in the tablebelow.Motors having code letters occurringlater in the alphabet may require alarger controller.

Motor HP RatingV/,,23-5T/i & above

Maximum AllowableMotor Code LetterLKH

Size

00

0

1

IP

13/<

LoadVolts1 1 52002303804605751 1 52002303804605751 1 52002303804605751 1 52301 1 5200230380460575

Max HP

Normal Duty1 Ph

V2

1

1

2

2

2

35

3Ph

m1'/2

1'/2

2

2

33555

71/27y2

101 010

1 0101 51 51 5

Plugging &Jogging Duty1Ph

'/2

1

1

2

1'/2

3

3Ph

1'/2

l'/2

V/2

2

2

33555

557'/27'/2

71/2

ContAmps

999999

1 8181818181 82727272727273535404040404040

ServiceLimitAmps

1 11 11 11 11 11 12121212121213232323232324242404040404040

Tungsten &BallastTypeLamp Amps430 VoltsMax

2020202020

3030303030

45454545454545

ResistanceHeating kW1 Ph

1 . 1 52.02.3

4.6 '5.82.34.04.6

9.21 1 . 53.566.9

13.817.358

1 1 . 55.8

1 01 1 . 5

2328.8

3Ph2.03.464.06.58.0

10.04.06.928.0

13.115.919.96.0

10.41 1 . 919.723.929.8

_

9.917.319.932.939.849.7

Transformer Switching 50-60HzKVA Rating Inrush Peak TimeContinuous Amps20 Times1 Ph

0.6

1 2

2.43.01.2

2.4

4.96.2

——

1.6

3.2

6.68.1

3Ph

1.82.1

4.25.2

3.64.3

8.51 1 . 0

——

4.95.75

1 1 . 214.5

20-40 Times1 Ph

03

0.6

1.21 . 50.6

1 . 2

2.53.1

——

0.8

1.6

3.34.1

3Ph

__

0.91.0

2 12.6

1.82 1

4.35.3

_

2.42.8

5.77 1

CapacitorKVASwitchingRating3PhKVAR

__

-

_

_

MechanicalLife

10 millionoperations

10 millionoperations

10 millionoperations

10 millionoperations

10 millionoperations

Siemens & Furnas Control Products