revised pdf version establishedfencing and ... track standards/go...metric conversion: 1...
TRANSCRIPT
-
AutoCAD SHX TextMETRIC CONVERSION: 1 inch=25.4mm, 1 foot=304.8mm
AutoCAD SHX TextDate
AutoCAD SHX TextRev
AutoCAD SHX TextPlan Number
AutoCAD SHX TextREFERENCE:
AutoCAD SHX TextSheet
AutoCAD SHX TextDrawn
AutoCAD SHX TextApproved
AutoCAD SHX TextChecked
AutoCAD SHX TextNo.
AutoCAD SHX TextRevision
AutoCAD SHX TextDate
AutoCAD SHX TextBy Approved
AutoCAD SHX TextStandard
AutoCAD SHX TextVP Engineering & Asset Management
AutoCAD SHX TextREVISED PDF VERSION ESTABLISHED
AutoCAD SHX Text18/08/31
AutoCAD SHX Text0
AutoCAD SHX Text0
AutoCAD SHX TextGTS-2211
AutoCAD SHX TextAUG 31/2018
AutoCAD SHX Text1 OF 1
AutoCAD SHX TextTS-2211
AutoCAD SHX TextMG
AutoCAD SHX TextGGS
AutoCAD SHX TextFENCING AND GATES
AutoCAD SHX TextRIGHT OF WAY
AutoCAD SHX TextBARBED WIRE-
AutoCAD SHX TextMAY BE STRUNG ALONG TOP OF FENCE IN
AutoCAD SHX TextSTOCK RANGE COUNTRY.
AutoCAD SHX TextSPECIAL
AutoCAD SHX TextFIVE WIRE FENCE
AutoCAD SHX TextLARGE STOCK COUNTRY
AutoCAD SHX TextTHREE DOUBLE STRAND WIRE CABLE
AutoCAD SHX TextTO BE TWISTED UNTIL POST IS 50.8 (2")
AutoCAD SHX TextOFF PLUMB
AutoCAD SHX Text50.8 (2")
AutoCAD SHX Text254 (10")
AutoCAD SHX TextSTRETCHING AT CORNERS-
AutoCAD SHX TextNEVER STRETCH
AutoCAD SHX TextFENCING AROUND CORNERS
AutoCAD SHX Text50.8 (2")
AutoCAD SHX Text254 (10")
AutoCAD SHX Text304.8 (12")
AutoCAD SHX Text101.6 (4")
AutoCAD SHX Text2.44m (8') POST
AutoCAD SHX Text2.36m (7'-9")
AutoCAD SHX TextSINGLE BRACE PANEL
AutoCAD SHX TextAT END OF FENCE AND CORNER POSTS
AutoCAD SHX TextPLACED
AutoCAD SHX TextATLANTIC PROVINCES/GATE OPENING APPROX. 4.72m (15'-6") / 4.89m (16') GATE
AutoCAD SHX TextQUEBEC & WEST/GATE OPENING APPROX. 5.33m (17'-6") / 5.49m (18') GATE
AutoCAD SHX Text330.2 (13")
AutoCAD SHX Text304.8 (12")
AutoCAD SHX Text254 (10")
AutoCAD SHX Text228.6 (9")
AutoCAD SHX Text1117.6 (3'-8")
AutoCAD SHX Text558.8 (22")
AutoCAD SHX Text152.4 (6")
AutoCAD SHX TextSTAPLES:
AutoCAD SHX Text38.1 (1 1/2")
AutoCAD SHX TextLONG
AutoCAD SHX Text- TOP FENCE WIRE TO BE DOUBLE STAPLED THROUGHOUT.
AutoCAD SHX Text- ARE TO BE USED TO FASTEN WIRE TO WOOD FENCE POSTS.
AutoCAD SHX Text- ARE TO BE SET DIAGONAL WITH GRAINBOF POST.
AutoCAD SHX Text- ARE TO BE DRIVEN AS FAR AS POSSIBLE WITHOUT
AutoCAD SHX Text PREVENTING FREE MOVEMENT OF WIRE LATERALLY.
AutoCAD SHX Text- ARE TO BE DRIVEN SECURELY IN END, CORNER OR
AutoCAD SHX TextGATE POSTS.
AutoCAD SHX TextFENCE WIRE
AutoCAD SHX Text- SHALL BE PLACED ON OUTER SIDE OF POSTS FROM THE TRACK.
AutoCAD SHX Text- ON CURVES SHALL BE ON OUTER SIDE OF POSTS FROM CENTRAL
AutoCAD SHX TextANGLE OF THE CURVE.
AutoCAD SHX Text- TO BE STRETCHED AS TIGHT AS POSSIBLE WITHOUT PULLING
AutoCAD SHX TextOUT TENSION CURVE.
AutoCAD SHX TextALL FENCE HEIGHTS
AutoCAD SHX TextSHALL BE 1372.6 (54")
AutoCAD SHX TextMINIMUM ABOVE GROUND
AutoCAD SHX Text254 (10")
AutoCAD SHX Text254 (10")
AutoCAD SHX Text152.4 (6")
AutoCAD SHX Text558.8 (22")
AutoCAD SHX Text228.6 (9")
AutoCAD SHX Text152.4 (6")
AutoCAD SHX Text203.2 (8")
AutoCAD SHX Text127 (5")
AutoCAD SHX Text1219.2 (4')
AutoCAD SHX TextIN ROCK LOCATIONS FULL DEPTH HOLES SHALL BE
AutoCAD SHX TextPROVIDED FOR END, CORNER AND GATE POSTS.
AutoCAD SHX TextFOR ALL OTHER POSTS.
AutoCAD SHX TextINTERMEDIATE POSTS MAY BE SET ON SILLS
AutoCAD SHX TextAND BRACED WITH BOULDERS PILED ON AND
AutoCAD SHX TextAROUND SILL AND POST AS SHOWN, BUT NOT
AutoCAD SHX TextMORE THAN TWO ADJACENT POSTS SHALL BE
AutoCAD SHX TextSET IN THIS MANNER. FULL DEPTH HOLES
AutoCAD SHX TextINSIDE OF POST ON LOWER HINGE.
AutoCAD SHX TextHINGE CLIP-2 PER GATE
AutoCAD SHX TextHINGE BOLTS-2 PER GATE
AutoCAD SHX TextNUTS FOR BOLTS-4 PER GATE
AutoCAD SHX TextPLATE WASHERS-4 PER GATE
AutoCAD SHX TextOUTSIDE OF POST ON UPPER HINGE,
AutoCAD SHX TextSINGLE GATE
AutoCAD SHX TextSINGLE GATE CHAINING
AutoCAD SHX TextTHE HORIZONTALL WIRES SHALL BE SPACED AND STRETCHED UNIFORMLY AND PARALLEL.
AutoCAD SHX TextVERTICAL AND UNIFORMLY SPACED.
AutoCAD SHX TextANY SHALL UNDULATIONS OF THE GROUND SHALL BE LEVELLED
AutoCAD SHX TextSO THAT BOTTOM WIRE OF FENCE IS UNIFORM DISTANCE
AutoCAD SHX TextFROM GROUND AND STRAIGHT BETWEEN POSTS.
AutoCAD SHX TextSTAY WIRES SHALL BE STRAIGHT AND
AutoCAD SHX Text- TWO 914.4m(3') LONG CEDAR CLEATS MADE FROM FENCE POSTS SPLIT IN HALF TO BE USED.
AutoCAD SHX Text - END, CORNER AND GATE POSTS SHALL BE ANCHORED AS SHOWN EXCEPT IN ROCK AREA.
AutoCAD SHX TextCOATED SPIRAL NAILS.
AutoCAD SHX Text-CLEATS TO BE NOTCHED INTO POST AND SECURELY SPIKED BY AT LEAST TWO
AutoCAD SHX Text(THIS PLAN FORMS PART OF THIS CIRCULAR).
AutoCAD SHX Text1. FOR SPECIFICATION OF WOVEN WIRE FENCE MATERIAL SEE 13-1
AutoCAD SHX TextFOR SPECIFICATION OF WOVEN WIRE FENCE GATES SEE 13-3
AutoCAD SHX Text(THIS PLAN FORMS PART OF THESE SPECIFICATIONS)
AutoCAD SHX Text2. FOR SPECIFICATION OF: WOOD FENCE POST SEE S4W-5.1
AutoCAD SHX Text3. FENCING & GATES TO BE INSTALLED AND MAINTAINED IN ACCORDANCE WITH
AutoCAD SHX TextRM RIGHT OF WAY FENCING & GATES.
AutoCAD SHX TextCAUSES PROBLEMS.
AutoCAD SHX Text- INSTALLED LARGE END DOWN
AutoCAD SHX Text- PLUMB
AutoCAD SHX Text- TRUE IN LINE AND
AutoCAD SHX Text- TROROUGHLY TAMPED
AutoCAD SHX TextINTERMEDIATE POSTS TO BE 2.44m (8') LONG AND
AutoCAD SHX Text1.52m (5') ABOVE GROUND LINE.
AutoCAD SHX TextINTERMEDIATE POSTS 2.74m (9') LONG, SET 1.22m (4')
AutoCAD SHX TextIN GROUND MAY BE USED WHERE FROST HEAVING
AutoCAD SHX Text5 & 9 WIRE FENCE IS SPECIFICALLY AUTHORIZED.
AutoCAD SHX TextTO BE USED ON ALL INSTALLATIONS EXCEPT WHERE
AutoCAD SHX Text50.8 (2") OFF PLUMB.
AutoCAD SHX TextTHREE DOUBLE STRAND WIRE CABLE
AutoCAD SHX TextTO BE TWISTED UNTIL POST IS
AutoCAD SHX TextOFTENER IN ROUGH TERRAIN OR WHERE LOCAL CONDITIONS FOR CLOSER BRACING.
AutoCAD SHX TextINTERMEDIATE POSTS TO BE 4.88 TO 7.62m (16'-25') APART MAXIMUM
AutoCAD SHX TextOFTENER IN ROUGH TERRAIN OR WHERE SERVICE REQUIRES CLOSER POSTS.
AutoCAD SHX TextIN LONG LINES OF FENCE DOUBLE BRACE PANELS TO BE SOACED 304.8m (1000') MAXIMUM IN NORMAL CONDITION.
AutoCAD SHX TextCONSTRUCTION
AutoCAD SHX TextGATES TO BE WELDED
AutoCAD SHX Text1219.2 (48") TO BE APPLIED
AutoCAD SHX TextNINE WIRE FENCING
AutoCAD SHX TextTO ALL GATES.
AutoCAD SHX TextSPIRAL NAILS.
AutoCAD SHX TextALL BRACES SHALL
AutoCAD SHX TextBE FENCE POSTS.
AutoCAD SHX TextBRACES TO BE GAINED INTO
AutoCAD SHX TextPOSTS AND SECURELY SPIKED
AutoCAD SHX TextBY AT LEAST TWO COATED
AutoCAD SHX TextHINGE SIDE
AutoCAD SHX TextDOUBLE PANEL ON GATE
AutoCAD SHX TextTIGHTLY BRACED
AutoCAD SHX TextPOSTS HOLDING GATE TO BE PLUMB
AutoCAD SHX TextTWIST WIRE UNTIL POST IS
AutoCAD SHX TextPROHIBITING AND ADJACENT LAND OWNERS AGREE
AutoCAD SHX TextPROVIDING LOCAL MUNICIPALITY HAS NO BY-LAW
AutoCAD SHX TextLOCKING SIDE.
AutoCAD SHX TextSINGLE PANEL ON GATE
AutoCAD SHX TextBY GRAVITY.
AutoCAD SHX TextGATE(S) SHALL
AutoCAD SHX TextBE HUNG, SO THAT
AutoCAD SHX TextTHEY SWING SHUT
AutoCAD SHX TextDOUBLE
AutoCAD SHX TextPANEL
AutoCAD SHX TextARRANGEMENT
AutoCAD SHX TextTO FENCE AGAINST PIGS.
AutoCAD SHX TextMAY BE USED ALONG BOTTOM OF
AutoCAD SHX TextWIRE FENCE WHERE IT IS NECESSARY
AutoCAD SHX TextMAXIMUM ABOVE GROUND
AutoCAD SHX TextALL FENCE HEIGHTS
AutoCAD SHX TextSHALL BE 1372 (54")
AutoCAD SHX TextDOUBLE
AutoCAD SHX TextPANEL
AutoCAD SHX TextARRANGEMENT
AutoCAD SHX TextBY GRAVITY.
AutoCAD SHX TextGATE SHALL
AutoCAD SHX TextBE HUNG, SO THAT
AutoCAD SHX TextTHEY SWING SHUT
AutoCAD SHX TextSHALL BE ANCHORED AS SHOWN
AutoCAD SHX TextPOSTS IN GROUND DEPRESSIONS
AutoCAD SHX TextSPLIT 1.22m (4') LONG POST
AutoCAD SHX TextSPLIT POST 1.22m (4') LONG
AutoCAD SHX Text76.2 X 152.4 X 3.175 (3" X 6" X 1/8") PROTECTION PLATE MOUNTED
AutoCAD SHX TextPOSITION
AutoCAD SHX TextTOP HINGE BOLT
AutoCAD SHX TextPLACED IN DOWNWARD
AutoCAD SHX TextFULLY THREADED
AutoCAD SHX Text"T" RAIL STEEL FENCE POSTS CLIPS (6/POST) COME IN;
AutoCAD SHX TextC
AutoCAD SHX TextW
AutoCAD SHX Text254 (10")
AutoCAD SHX Text152.4 (6")
AutoCAD SHX Text152.4 (6")
AutoCAD SHX Text152.4 (6")
AutoCAD SHX Text203.2 (8")
AutoCAD SHX Text127 (5")
AutoCAD SHX Text127 (5")
AutoCAD SHX Text152.4 (6")
AutoCAD SHX Text419.1 (16 1/2")
AutoCAD SHX Text152.4 (6")
AutoCAD SHX Text304.8 (12")
AutoCAD SHX Text101.6 (4")
AutoCAD SHX Text101.6 (4")
AutoCAD SHX Text50.8 (2")
AutoCAD SHX Text50.8 (2")
AutoCAD SHX Text50.8 (2")
AutoCAD SHX Text2.44m (8') POST
AutoCAD SHX Text2.36m (7'-9")
AutoCAD SHX Text2.36m (7'-9")
AutoCAD SHX Text304.8 (12")
AutoCAD SHX Text457.2 (18")
AutoCAD SHX Text457.2 (18")
AutoCAD SHX Text914.4 (3')
AutoCAD SHX TextSPECIAL
AutoCAD SHX TextNINE WIRE FENCE
AutoCAD SHX TextSMALL STOCK COUNTRY
AutoCAD SHX TextBARBED WIRE:
AutoCAD SHX TextTYPICAL ARRANGEMENT
AutoCAD SHX TextFOR GENERAL USE
AutoCAD SHX TextSEVEN WIRE FENCE
AutoCAD SHX TextSPECIAL
AutoCAD SHX TextTHREE STRAND BARBED WIRE FENCE
AutoCAD SHX TextDOUBLE BRACE PANEL
AutoCAD SHX TextDOUBLE GATE
AutoCAD SHX TextWHERE APPROVED BY TRACK & ROADWAY ENGINEER
AutoCAD SHX TextSTOP DETAIL
AutoCAD SHX Text228.6 (9") ABOVE
AutoCAD SHX TextROADWAY
AutoCAD SHX TextDOUBLE GATE CHAIN
AutoCAD SHX TextTO SUIT GATES
AutoCAD SHX Text228.6-254 (9"-10") LONG
AutoCAD SHX TextREMARKS:
AutoCAD SHX TextTYPICAL GATE BRACING ARRANGEMENT
AutoCAD SHX TextANCHORING:
AutoCAD SHX TextDEPRESSIONS-HILLS-HOLLOES
AutoCAD SHX TextSPECIAL CARE SHOULD BE TAKEN WHEN SETTINGS
AutoCAD SHX TextPOSTS IN SLIGHT HOLLOWS AND STEEP GRADES.
AutoCAD SHX TextTYPICAL ROCK SITE INSTALLATION
AutoCAD SHX TextDETAIL OF WIRE SPLICE
AutoCAD SHX TextDETAIL OF 3/4" HINGE BOLTS
AutoCAD SHX Text304.8 (12")
AutoCAD SHX Text69.85(2 3/4")
AutoCAD SHX TextGATE
AutoCAD SHX TextTO
AutoCAD SHX TextOPEN
AutoCAD SHX TextAWAY
AutoCAD SHX TextFROM
AutoCAD SHX TextTRACK
AutoCAD SHX TextALL FENCE POSTS MUST BE:
AutoCAD SHX Text1270 (4'-2")
AutoCAD SHX Text- 2.44m (8') LENGTH WITH FIX ANCHOR PLATE.
AutoCAD SHX Text- 2.44m (8') 2.59m(8'-6") 2.74m(9' LENGTHS WITHOUT ANCHOR PLATES.
AutoCAD SHX Text- 2.44m (8') LENGTH WITH DETACHABLE ANCHOR PLATES.
AutoCAD SHX TextSPECIAL DOUBLE GATE/GATE OPENING APPROX. 7.39m (24'-3") / TWO 3.66m (12') GATES.
AutoCAD SHX Text2.74m (9') POST
AutoCAD SHX Text2.74m (9') POST
AutoCAD SHX Text2.74m (9') POST
AutoCAD SHX Text2.44m (8') POST
AutoCAD SHX Text203.2 (8")
AutoCAD SHX Text203.2 (8")
AutoCAD SHX Text152.4 (6")
AutoCAD SHX Text152.4 (6")
AutoCAD SHX Text152.4 (6")
AutoCAD SHX Text127 (5")
AutoCAD SHX Text127 (5")
AutoCAD SHX Text101.6 (4")
AutoCAD SHX Text203.2 (8")
AutoCAD SHX Text203.2 (8")
AutoCAD SHX Text152.4 (6")
AutoCAD SHX Text152.4 (6")
AutoCAD SHX Text152.4 (6")
AutoCAD SHX Text127 (5")
AutoCAD SHX Text127 (5")
AutoCAD SHX Text101.6 (4")
AutoCAD SHX Text1219.2 (4')
AutoCAD SHX Text1219.2 (4')
AutoCAD SHX Text152.4 (6") PIG TALL HOOK
AutoCAD SHX Text38.1 (1 1/2") STAPLE
AutoCAD SHX Text533-584 (21"-23") LENGHT OF CHAIN
AutoCAD SHX Text38.1 (1 1/2")
AutoCAD SHX Text152.4 (5') POST HEIGHT
Sheets and ViewsModel