Page 1: ROHR2 31.2a Interfaces feature list - N.A Tecnologia · SDNF Format : see . 5: optional ... To simplify the data interchange with CAD systems, the format of the neutral interface

ROHR2 Program System ROHR2

Interfaces - Overview and Details

SIGMA Ingenieurgesellschaft mbH

Page 2: ROHR2 31.2a Interfaces feature list - N.A Tecnologia · SDNF Format : see . 5: optional ... To simplify the data interchange with CAD systems, the format of the neutral interface
Page 3: ROHR2 31.2a Interfaces feature list - N.A Tecnologia · SDNF Format : see . 5: optional ... To simplify the data interchange with CAD systems, the format of the neutral interface

ROHR2 interfaces Feature list

ROHR2_Interfaces SIGMA Ingenieurgesellschaft mbH www.rohr2.com

Content

ROHR2 Introduction .................................................................................................................................... 1

1  Integration of ROHR2 .................................................................................................................................. 1 

2  ROHR2 interfaces - overview ..................................................................................................................... 2 

3  Interfaces to CAD-Systems ........................................................................................................................ 3 3.1  3D CAD-Systems - Overview ........................................................................................................................ 3 

3.1.1  Scope of transferred data .............................................................................................................................. 4 3.2  Neutral Interface ............................................................................................................................................ 4 

3.2.1  Data import form CAD systems ..................................................................................................................... 4 3.2.2  Neutral file Data export .................................................................................................................................. 5 

3.3  Extended results export to PDMS ................................................................................................................ 6 3.4  Interface PDS ................................................................................................................................................ 7 3.5  Interface PCF ................................................................................................................................................ 8 3.6  Interface PXF ................................................................................................................................................ 9 3.7  Interface PASCE ........................................................................................................................................... 9 3.8  Export of graphics ....................................................................................................................................... 10 

4  Interfaces to CAE-Systems ...................................................................................................................... 11 4.1  Overview ..................................................................................................................................................... 11 

4.1.1  Support design ............................................................................................................................................ 11 4.1.2  Pipe Stress Calculation ............................................................................................................................... 11 4.1.3  Pressure loss / Fluid dynamics .................................................................................................................... 11 

4.2  Export of support data ................................................................................................................................. 12 4.2.1  Export of general support data .................................................................................................................... 12 4.2.2  Support data Interfaces LICAD, FLEXPERTE, CASCADE ......................................................................... 12 

4.3  CAESAR II Interface.................................................................................................................................... 13 4.3.1  CAESAR II Import ....................................................................................................................................... 13 4.3.2  CAESAR II Export Interface ........................................................................................................................ 13 

4.4  PIPESTRESS - Data import Interface ........................................................................................................ 13 4.5  KWUROHR Import Interface ....................................................................................................................... 14 4.6  SINETZ Export Interface ............................................................................................................................. 14 4.7  Fluid dynamic programs .............................................................................................................................. 15 

4.7.1  Import of load -time-functions ...................................................................................................................... 15 4.7.2  PIPENET Data export Interface .................................................................................................................. 15 

5  Interfaces to Steel Construction Programs ............................................................................................ 16 5.1  Interface SDNF - ROHR2 ............................................................................................................................ 16 

6  Third Party Interfaces ............................................................................................................................... 17 

Stand 14.02

Page 4: ROHR2 31.2a Interfaces feature list - N.A Tecnologia · SDNF Format : see . 5: optional ... To simplify the data interchange with CAD systems, the format of the neutral interface

ROHR2 interfaces Feature list Page 1 - Integration of ROHR2

ROHR2_Interfaces

1 Integration of ROHR2

The program system ROHR2 is the CAE System for Component analysis, Engineering and Structure Analysis of Piping Systems. Several interfaces are part of the "standard" ROHR2 program: besides several document and graphic file types.

A variety of interfaces to CAD/CAE-systems are available to integrate ROHR2 into your workflow. The integration of ROHR is completed by third-party interface products. Concerning the optimization of your workflow our staff of specialists will advise you individually upon request, especially regarding the data import and export to ROHR2.

SIGMA Ingenieurgesellschaft mbH www.rohr2.com

Page 5: ROHR2 31.2a Interfaces feature list - N.A Tecnologia · SDNF Format : see . 5: optional ... To simplify the data interchange with CAD systems, the format of the neutral interface

ROHR2 interfaces Feature list Page 2 - ROHR2 interfaces - overview

ROHR2_Interfaces SIGMA Ingenieurgesellschaft mbH www.rohr2.com

2 ROHR2 interfaces - overview

ROHR2 availalbe interfaces - Overview Import / Export

Standard package

Optional available interfaces

Support data Interface EXP X

LICAD / CASCADE / FLEXPERTE EXP X

Neutral Interface ROHR2 IMP+EXP X

CAESAR II IMP X

EXP X

PIPESTRESS IMP X

KWUROHR IMP X

PCF IMP X

EXP X

PDMS IMP X

EXP X

PDS IMP X

PASCE IMP X

Autoplant IMP X

SDNF IMP X

SINETZ Pressure loss calculation EXP X

PIPENET Fluid flow calculation IMP X

EXP X Part of the standard delivery of ROHR2 Static/Static and Dynamic and integrated into ROHR2. Optional availalbe interface modules are not part of the ROHR2 Static & Dynamic standard package. *) Country specific program versions or floating licenses may differ from this specification.. SINETZ: Pressure drop and temperature loss analysis in pping systems. A product of SIGMA Ingenieurgesellschaft mbH.

Page 6: ROHR2 31.2a Interfaces feature list - N.A Tecnologia · SDNF Format : see . 5: optional ... To simplify the data interchange with CAD systems, the format of the neutral interface

ROHR2 interfaces Feature list Page 3 - Interfaces to CAD-Systems

ROHR2_Interfaces SIGMA Ingenieurgesellschaft mbH www.rohr2.com

3 Interfaces to CAD-Systems

The data for generating a pipe model in ROHR2 is done by importing files from 3D Plant engineering systems by integrated interfaces (some of them optionally available). This way to import data is basing on integrated component databases or database reports instead of simple graphic data. This enables to get more information than a simple piping structure, like assignment of materials, dimensions or support positions, required for the modeling in the ROHR2 pipe s tress calculation ROHR2

3.1 3D CAD-Systems - Overview These CAD-systems are currently supported by ROHR2.

AVEVA PDMS see 3.2, 3.2.2, 3.3

Neutral interface Neutral interface extended results export

CADISON MPDS4 HiCADnext ROHRCAD / RC-PLANET

see 3.2 Neutral interface

PDS Stress interface see 3.4 optional available

PCF interface e.g. connection to Plant3D, Smartplant

see 3.5 optional available

AUTOPLANT PXF see 3.6 optional available

PASCE see 3.7 optional available

SDNF Format see 5 optional available An additonal module on CAD side may be requiredto transfer datato/from ROHR2. Please check with the CAD/CAE supplier. Addresses see 6. Please ask for detailed information and sample files. The list of interfaces will be continued. The ROHR2 Neutral Interface is the main program module for the integration of CAD-programs (for details please refer to 3.2). The neutral interface and specific interface programs are additional programs included in ROHR2. They may be acquired as an upgrade to existing ROHR2 program installations. The creation of a piping model by means of graphics data information (e. g. AUTOCAD *.dwg) allows to generate a geometry model in best case. ROHR2 does not support this working method, because modeling in ROHR2win is the more efficient way to get a piping model.

Page 7: ROHR2 31.2a Interfaces feature list - N.A Tecnologia · SDNF Format : see . 5: optional ... To simplify the data interchange with CAD systems, the format of the neutral interface

ROHR2 interfaces Feature list Page 4 - Interfaces to CAD-Systems

ROHR2_Interfaces

3.1.1 Scope of transferred data Automatic generation of the ROHR2 input data from CAD-systems, in detail (if available):

• Geometry data Enables automatic generation of the load cases dead weight, medium weight and operation. Stresses and loads can be determined according to the calculation standard.

• Diameter, Wall thickness` • Materials • Support points and support conditions • Tees • Instruments, flanges • Expansion joints • Reducers • Design data, operation data

3.2 Neutral Interface

3.2.1 Data import form CAD systems Interface for data exchange between ROHR2 and optional available ROHR2 Interfaces as well as various CAD-systems like • AVEVA PDMS • INTERGRAPH - SMARTPLANT • CADISON • HiCADnext • ROHR2CAD / RC-PLANET To simplify the data interchange with CAD systems, the format of the neutral interface was defined. Being based on the listing of all elements in the system (pipe, bend, instruments, supports, ...) it can be created e.g. by a report from a database. For each element parameters required by ROHR2 have to be indicated. But only a part of the parameters must be entered by the user, not indicated parameters are filled with standard values or calculated from other parameters. The elements are written into an ASCII file as data sets with defined record label and corresponding parameters.

General description • For each element a reference string may be entered to identify the element after the conversion

from ROHR2 to the CAD-System. • Input records can be in arbitrary order. • Parameters within an input record can be in arbitrary order. • Only a part of the parameters must be entered by the user, not indicated parameters are filled with

standard values or calculated from other parameters. • Insert coordinates by node name or directly. If the coordinates are put in directly, node names are

created automatically • All existing names in the MATDAT file may be used as material name. A translation table for the

names, not included in MATDAT, may be created. • All data from the ROHR2 databases can be used • The expected file extension is *.ntr.

SIGMA Ingenieurgesellschaft mbH www.rohr2.com

Page 8: ROHR2 31.2a Interfaces feature list - N.A Tecnologia · SDNF Format : see . 5: optional ... To simplify the data interchange with CAD systems, the format of the neutral interface

ROHR2 interfaces Feature list Page 5 - Interfaces to CAD-Systems

ROHR2_Interfaces SIGMA Ingenieurgesellschaft mbH www.rohr2.com

Defined pipe elements The following pipe components are defined: • Straight pipe • Structural sections (profiles) • Bend • Reinforced tee • Weldolet • Tee (fitting) • Reducer • Flange • Instrument • Angle valve • 3-, 4-way valve • Axial expansion joint • Angular expansion joint • Lateral expansion joint • Any rigid element with 2 connections

The coordinates of the start and end points must be indicated for each pipe element. Not defined parameters like material or loads are replaced by default values. Line masses are given or calculated according to the dimensions.

Defined support types Any type of support may be converted. Support types are pre-defined for frequently used supports, e.g.: Support type Support direction Spring hanger Vertical translations Rigid hanger Vertical translations Constant hanger Vertical translations Fixed point All translations and rotations Guide bearing Translations cross to pipe axis (horizontal and vertical) Slide bearing Vertical translations Axial stop Translations in pipe axis Transverse stop All horizontal translations cross to pipe axis Guide bearing with axial stop All translations Slide bearing with axial stop Vertical translations and the translations in pipe axis are fixed Transverse- and Axial stop Horizontal transverse motions and the translations in pipe axis are

fixed Spring support Vertical translations. The spring rate works in vertical direction Spring support with bearing All translations cross to pipe axis (horizontal and vertical). The spring

rate works in vertical direction Angulating support Given support direction At supports the friction coefficient and support gap may be put in for each direction.

3.2.2 Neutral file Data export The data transfer in the ROHR2 Neutral file format (*.ntr) is carried out by the ROHR2 function File| Export| Neutral|topic. The Neutral interface is included in ROHR2 Static and Dynamic. For details please refer to the separate manual, which is part of the interface software.

Page 9: ROHR2 31.2a Interfaces feature list - N.A Tecnologia · SDNF Format : see . 5: optional ... To simplify the data interchange with CAD systems, the format of the neutral interface

ROHR2 interfaces Feature list Page 6 - Interfaces to CAD-Systems

ROHR2_Interfaces

3.3 Extended results export to PDMS Interface between AVEVA PDMS and ROHR2. AVEVA PDMS 3D design software is a product of AVEVA Group plc, Cambridge, UK (www.aveva.com). The data transfer from PDMS to ROHR2 is carried out by the ROHR2 Neutral interface. Additionally the export of calculation results to PDMS is done by the ROHR2 integrated PDMS export function. Requirements of the data transfer: • An AVEVA PDMS license including: AVEVA Pipe Stress Interface - R2 • a current program license of ROHR2 including neutral interface The neutral interface is part of the program system ROHR2.

PDMS ROHR2AVEVAPDMS

ROHR2 InterfaceROHR2 Neutral

Interface

ROHR2 PDMSexport

interface

The data exchange process: 1. Transfer from PDMS to ROHR2 (import of data into ROHR2) The conversion from PDMS to ROHR2 is carried out in two steps: • The PDMS Interface creates data in the format of the ROHR2 neutral interface.

The scope of conversion depends on the parameters defined by PDMS. • The created .NTR-file is read by the neutral interface (integrated in ROHR2). The complete pipe geometry incl. materials, insulation and design data details as well as support types are taken over in details, if they are defined in PDMS (corresp. attribute must be set in PDMS) 2. Transfer ROHR2 to PDMS (ROHR2 data export) The data export from ROHR2 to PDMS includes load case dependent support results and deformations. It is carried out in two steps, too: • data is written into PDMS adapted export files. • The files are taken over by the PDMS Interface into the PDMS model and shown. Deformed structures may be represented in PDMS by this way. Beyond that, in PDMS calculation results are stored for further treatment, e.g. in hanger design software. Please ask for detailed information and sample files.

SIGMA Ingenieurgesellschaft mbH www.rohr2.com

Page 10: ROHR2 31.2a Interfaces feature list - N.A Tecnologia · SDNF Format : see . 5: optional ... To simplify the data interchange with CAD systems, the format of the neutral interface

ROHR2 interfaces Feature list Page 7 - Interfaces to CAD-Systems

ROHR2_Interfaces SIGMA Ingenieurgesellschaft mbH www.rohr2.com

3.4 Interface PDS Interface to convert the output data from the PDS Stress Interface into the ROHR2 neutral file format. Intergraph PDS is a CAD/CAE application for plant design and construction by Intergraph Corporation, Huntsville, AL, USA (www.intergraph.com). The import of Intergraph-PDS data into ROHR2 is carried out by the PDS Stress Interface. Requirements of the data transfer: - the current program license ROHR2 - the Interface Intergraph PDS - ROHR2 - the ROHR2 Neutral Interface The conversion is carried out by two steps: • The PDS Interface creates data in the format of the ROHR2 neutral interface.

The scope of conversion depends on the parameters defined by Intergraph PDS. • The created .NTR-file is read by the neutral interface (integrated in ROHR2WIN). The neutral interface requires a file format to be created by the Intergraph PDS Stress Interface, which can be adjusted by means of the configuration file DEFAULTS.DAT. A template file DEFAULTS.DAT is available. The data conversion into the neutral interface format is controlled by the parameter file ign.env. Materials, support conditions as well as expansion joint parameters are determined by tables from the PDS data. Components to be transformed Components of the Intergraph PDS Stress Interface to be converted are: Generic name (PDS) Meaning 3W 3-way valve 4W 4-way valve AV Angle valve CR Crossing EL Bend ER Eccentric reducer FL Flange HA Support MT Miter (Segment) PI Pipe RB Rigid Body RD Concentric reducer RI Bending TE Tee TF Welded nozzle VA Instrument FX Expansion joint

Page 11: ROHR2 31.2a Interfaces feature list - N.A Tecnologia · SDNF Format : see . 5: optional ... To simplify the data interchange with CAD systems, the format of the neutral interface

ROHR2 interfaces Feature list Page 8 - Interfaces to CAD-Systems

ROHR2_Interfaces SIGMA Ingenieurgesellschaft mbH www.rohr2.com

3.5 Interface PCF The PCF interface is used to convert data in PCF format into ROHR2 and to export ROHR2 system data in *.pcf format. The PCF format is used by several CAD-systems to create isometrics like AUTODESK Autocad Plant3D ; Intergraph Smartplant Pro/ENGINEER.

PCF data import This interface is used to convert data from several CAD systems into ROHR2. A configuration file is used to adapt the interface to the data generated by the CAD-system.

Requirements of the data transfer • a current program license of ROHR2 • the Interface PCF- ROHR2 • the ROHR2 Neutral interface The conversion is carried out by two steps: • To read PCF files use the command File| Open. Selected file type must be ALIAS PCF (*.pcf). • During this process the pcf-files are translated into the format of the neutral interface). The scope of

conversion depends on the parameters delivered by Alias PCF. In the dialog window File |Open several files can be selected. The data of all files is taken over into the calculation system. The interface PCF- ROHR2 is an optional available program module to be integrated into ROHR2. For details please refer to the separate manual, which is part of the interface software.

PCF data export The PCF - ROHR2 interface includes the export of ROHR2 system data in PCF format. The export of data in PCF format (*.pcf) is done in ROHR2win by the function File| Export| PCF. The PCF Export is part of the PCF Interface). For details please refer to the separate manual, which is part of the interface software.

Requirements of the data transfer • a current program license of ROHR2 • the interface PCF- ROHR2

Page 12: ROHR2 31.2a Interfaces feature list - N.A Tecnologia · SDNF Format : see . 5: optional ... To simplify the data interchange with CAD systems, the format of the neutral interface

ROHR2 interfaces Feature list Page 9 - Interfaces to CAD-Systems

ROHR2_Interfaces SIGMA Ingenieurgesellschaft mbH www.rohr2.com

3.6 Interface PXF Interface to convert data from PXF format (AUTOPLANT) into the ROHR2 neutral interface format. Requirements of the data transfer: • a current program license of ROHR2 • the Interface AUTOPLANT ROHR2 • the ROHR2 Neutral interface The conversion is carried out by two steps: • Open the AUTOPLANT *.pxf files (*.pxf) in ROHR2win by using the File| Open command. Selected

file type must be AUTOPLANT. • During this process the PXF files are translated into the format of the neutral interface (see Neutral

interface - data import). The scope of conversion depends on the parameters delivered by AUTOPLANT

In the dialog window File |Open several files can be selected. The data of all files is taken over into the calculation system. The interface AUTOPLANT - ROHR2 is an optional available program module to be integrated into ROHR2. For further details please refer to the separate manual, which is part of the interface software.

3.7 Interface PASCE Interface to transmit the output data of the PASCE Stress Interface, AEA Technology Engineering Software, into the ROHR2 neutral interface format.

Requirements of the data transfer • a current program license of ROHR2 • the Interface PASCE-ROHR2 • the ROHR2 Neutral interface The conversion is carried out by two steps: • Open the PASCE *.ntl files (*.ntl) in ROHR2win by using the File| Open command, . Selected file

type must be PASCE. • During this process the NTL files are translated into the format of the neutral interface (see Neutral

interface - data import, Fehler! Verweisquelle konnte nicht gefunden werden.). These files contain geometry and dimensions of the system. Supports come from a file with the same name and the file extension *.SUP.The scope of conversion depends on the parameters delivered by PASCE

In the dialog window File |Open several files can be selected. The data of all files is taken over into the calculation system. The interface PASCE - ROHR2 is an optional available program module to be integrated into ROHR2. For further details please refer to the separate manual, which is part of the interface software.

Page 13: ROHR2 31.2a Interfaces feature list - N.A Tecnologia · SDNF Format : see . 5: optional ... To simplify the data interchange with CAD systems, the format of the neutral interface

ROHR2 interfaces Feature list Page 10 - Interfaces to CAD-Systems

ROHR2_Interfaces

3.8 Export of graphics

Export from ROHR2 ROHR2drawings can be exported into the file formats:

- Metafile (*.emf) - HPGL - DXF

The export into dxf format e.g. can be used for processing in AUTOCAD. The generated data is of 2D dxf drawing type with restricted modification capability.

ROHR2 Project , isometric drawings made by means of the additonal module

ROHR2iso

OHR2 DXF Export

SIGMA Ingenieurgesellschaft mbH www.rohr2.com

Page 14: ROHR2 31.2a Interfaces feature list - N.A Tecnologia · SDNF Format : see . 5: optional ... To simplify the data interchange with CAD systems, the format of the neutral interface

ROHR2 interfaces Feature list Page 11 - Interfaces to CAE-Systems

ROHR2_Interfaces SIGMA Ingenieurgesellschaft mbH www.rohr2.com

4 Interfaces to CAE-Systems

4.1 Overview Currently the following CAE-systems are supported.

4.1.1 Support design

Support data Interface see 4.2 included in ROHR2

LICAD (Lisega) Export of support data see 4.2.2 included in ROHR2 CASCADE (Witzenmann) Export of support data see 4.2.2 included in ROHR2

FLEXPERTE (Witzenmann) Export of support data see 4.2.2 included in ROHR2

4.1.2 Pipe Stress Calculation CAESAR II Import Import of data in CAESAR II

Generic Neutral File Format (*.CII)

see 4.3.1 included in ROHR2

CAESAR II Export Export of ROHR2 data into CII Neutral File Format (*.CII)

see 4.3.2 optional available

PIPESTRESS Import Transfer of input data of the program system PIPESTRESS

see 4.4 included in ROHR2

KWUROHR (Siemens) Import Interface see 4.5 optional available

4.1.3 Pressure loss / Fluid dynamics

SINETZ ROHR2-SINETZ Export Interface

see 4.6 included in ROHR2

Fluid dynamics Import of Fluid hammer forces see 4.7.1 included in ROHR2 PIPENET Data exchange between ROHR2

and PIPENET See 4.7.2 and 4.7.1

optional available

Please ask for detailed information and sample files.

Page 15: ROHR2 31.2a Interfaces feature list - N.A Tecnologia · SDNF Format : see . 5: optional ... To simplify the data interchange with CAD systems, the format of the neutral interface

ROHR2 interfaces Feature list Page 12 - Interfaces to CAE-Systems

ROHR2_Interfaces

4.2 Export of support data

4.2.1 Export of general support data Data of all supports may be exported for further treatment. By using the function Export data in Loads| Tasks| Extreme value calculation, a fixed-format text file, (file extension *.sup). This file is the basis of the export of support data (LICAD, CASCADE), FLEXPERTE.

ROHR2 Export Supports

4.2.2 Support data Interfaces LICAD, FLEXPERTE, CASCADE The interface ROHR2 - LICAD exports support data from ROHR2 into the hanger and support design system LICAD (LISEGA GmbH, www.lisega.de). The interface ROHR2 - CASCADE exports support data from ROHR2 into the hanger and support design system CASCADE (Witzenmann GmbH, www.witzenmann.de). The interface ROHR2 - FLEXPERTE exports support data from ROHR2 into the hanger and support design system FLEXPERTE (Witzenmann GmbH, www.witzenmann.de). The design of supports will be prepared by the transfer of support data from ROHR2 into the planning system FLEXPERTE. A formatted text file is written, where all supports, to be exported, are listed. For each hanger the coordinates and maximum displacements and forces are given. The interfaces ROHR2 - LICAD, ROHR2 - FLEXPERTE, ROHR2 - CASCADE are part of the ROHR2 standard version.

SIGMA Ingenieurgesellschaft mbH www.rohr2.com

Page 16: ROHR2 31.2a Interfaces feature list - N.A Tecnologia · SDNF Format : see . 5: optional ... To simplify the data interchange with CAD systems, the format of the neutral interface

ROHR2 interfaces Feature list Page 13 - Interfaces to CAE-Systems

ROHR2_Interfaces SIGMA Ingenieurgesellschaft mbH www.rohr2.com

4.3 CAESAR II Interface Interface for the data exchange between ROHR2 and CAESAR II. CAESAR II is a product of Intergraph Corporation, Huntsville, AL, USA (www.intergraph.com). Enables to read and write data in the format of the CAESAR II Neutral File. Nearly all import calculation data will be transmitted to be used by both of the program systems.

4.3.1 CAESAR II Import The program system ROHR2 includes the interface to import CAESAR II calculation data. Data in the Caesar II neutral file format (*.CII, Version 4.3 or higher) may be imported. The CAESAR II Import interface is part of the ROHR2 Standard package.

4.3.2 CAESAR II Export Interface For the export of data from ROHR2 into Caesar II the ROHR2-CII Export Interface is available. It enables to convert the ROHR2 system data into the Caesar II Neutral File Format von (*.CII, Version 5.30). The ROHR2-CAESAR II Export interface is an optional available program in the program system ROHR2. For further details please refer to the separate manual, which is part of the interface software. The data transfer is carried out in ROHR2win by File| Export| CAESAR II Neutral File.

4.4 PIPESTRESS - Data import Interface The interface PIPESTRESS - ROHR2 is used to convert input data of the program system PIPESTRESS (DST Computer Services S.A.) into ROHR2.

Integrated Import-Interface The program system ROHR2 includes the interface to import PIPESTRESS calculation data.

Requirements of the data transfer into ROHR2 • a current program license of ROHR2 To read PIPESTRESS files (*.fre) use the File| Open command. Selected file type must be PIPESTRESS. For further details please refer to the documentation.

Page 17: ROHR2 31.2a Interfaces feature list - N.A Tecnologia · SDNF Format : see . 5: optional ... To simplify the data interchange with CAD systems, the format of the neutral interface

ROHR2 interfaces Feature list Page 14 - Interfaces to CAE-Systems

ROHR2_Interfaces

4.5 KWUROHR Import Interface Interface to convert data from SIEMENS KWUROHR into the ROHR2 neutral interface format. The interface enables to import KWUROHR input files. The data of the KWUROHR model is converted into the ROHR2 neutral file, to be opened by ROHR2win. Load case depending data is not converted. Required file extension is *.kwu (file must be renamed before, if required).

Requirements of the data transfer: • a current program license of ROHR2 • the Interface KWUROHR- ROHR2 • the ROHR2 Neutral interface The conversion is carried out by two steps: • To read KWUROHR files use the File| Open command. Selected file type must be (*.kwu). • During this process the kwu-files are translated into the format of the neutral interface The scope

of conversion depends on the parameters delivered by KWUROHR In the dialog window File |Open several files can be selected. The data of all files is taken over into the calculation system. The interface KWUROHR - ROHR2 is an optional available program module to be integrated into ROHR2. For further details please refer to the separate manual, which is part of the interface software.

4.6 SINETZ Export Interface

Fluid analysis (e.g. pressure loss calculation) SINETZ, program for the steady state calculation of flow distribution, pressure drop and heat loss in branched and intermeshed piping networks for compressible and incompressible media. (Product of SIGMA Ingenieurgesellschaft mbH) The SINETZ program normally includes a neutral interface to import data from CAD/CAE programs. It enables to import geometry data, dimensions, insulation, components like bends, instruments, pumps, reducers and orifices as well as boundary conditions (pressure, temperature and quantities). The SINETZ neutral file format export interface is included in ROHR2.

ROHR2SINETZROHR2-SINETZ

interface

Part of StandardROHR2WIN

SINETZNeutral File Format

SIGMA Ingenieurgesellschaft mbH www.rohr2.com

Page 18: ROHR2 31.2a Interfaces feature list - N.A Tecnologia · SDNF Format : see . 5: optional ... To simplify the data interchange with CAD systems, the format of the neutral interface

ROHR2 interfaces Feature list Page 15 - Interfaces to CAE-Systems

ROHR2_Interfaces SIGMA Ingenieurgesellschaft mbH www.rohr2.com

4.7 Fluid dynamic programs

4.7.1 Import of load -time-functions

Import of fluid hammer forces into ROHR2 For the conversion of load-time functions ROHR2 provides an import capability. It is used to import data of various fluid dynamic softwares. ROHR2 converts *.csv-files or ASCII files into a proprietary ROHR2 binary format. Data, created by programs like PIPENET, DRAKO or INROS can be converted this way. The import featuree is part of the ROHR2 Static and Dynamic standard version.

4.7.2 PIPENET Data export Interface

Fluid flow calculation Interface for the exchange of data between ROHR2 and PIPENET (Sunrise Systems Ltd, www.sunrise-sys.com). PIPENET is a software tool for rapid flow analysis of pipe and duct networks and dynamic fluid hammer forces to be used as loads for dynamic fluid hammer calculations of the ROHR2 framework. ROHR2 creates an input file for PIPENET on the basis of an template. The entire ROHR2 model is converted into PIPENET format. If the current load case is of the type Fluid hammer dynamically, additionally the fluid hammer forces at bends , branches and reducers can be generated in the ROHR2 model and exported to PIPENET. After finishing the fluid hammer analysis with PIPENET the file containing the PIPENET Load-time-functions can be imported into ROHR2. In this case the fluid hammer forces are defined by PIPENET and the fluid hammer calculation of the framework in ROHR2 can be carried out without additional manual inputs. The data exchange is done in ROHR2 in the file format *.sdf by means of the function File| export PIPENET.

PIPENET Export Interface The PIPENET Export interface is an optional availalbe interface module.

PIPENET Data import For the import of load-timefunctions from PIPENET into ROHR2, see 4.7.1

Page 19: ROHR2 31.2a Interfaces feature list - N.A Tecnologia · SDNF Format : see . 5: optional ... To simplify the data interchange with CAD systems, the format of the neutral interface

ROHR2 interfaces Feature list Page 16 - Interfaces to Steel Construction Programs

ROHR2_Interfaces SIGMA Ingenieurgesellschaft mbH www.rohr2.com

5 Interfaces to Steel Construction Programs

5.1 Interface SDNF - ROHR2 Interface to convert output data from SDNF format (Structural steel Detailing Neutral File) into the ROHR2 neutral interface format. The interface SDNF - ROHR2 is an optional available program module to be integrated into ROHR2.

Requirements of the data transfer: • a current program license of ROHR2 • the ROHR2 SDNF Interface • the ROHR2 Neutral interface

The conversion is carried out in two steps: • The SDNF Interface creates data in the format of the ROHR2 neutral interface. • The created .NTR-file is read by the neutral interface (integrated in ROHR2).

Page 20: ROHR2 31.2a Interfaces feature list - N.A Tecnologia · SDNF Format : see . 5: optional ... To simplify the data interchange with CAD systems, the format of the neutral interface

ROHR2 interfaces Feature list Page 17 - Third Party Interfaces

ROHR2_Interfaces

6 Third Party Interfaces

The integration of ROHR is supported by third-party interface products. In case of questions or information requests, please contact the manufacturer. We will be pleased to advise you regarding the data import and export to ROHR2. For updated information and links to software companies please refer to www.rohr2.com. Produkt

Anbieter

AVEVA PDMS AVEVA Pipe Stress Interface - R2

AVEVA Solutions Ltd. Cambridge , United Kingdom www.aveva.com AVEVA GmbH Sulzbach, Germany www.aveva-gmbh.de

CADISON ROHR2 Interface With CADISON technology, all relevant properties of designed 3D piping can be exported to an NTR file containing the described analysis data and then automatically transferred to the ROHR2 stress calculation program.

ITandFactory GmbH 65812 Bad Soden www.itandfactory.com

HICAD - ROHR2- Interface

ISD Software und Systeme GmbH D-44227 Dortmund ISD Switzerland CH-4500 Solothurn / Switzerland www.isdgroup.com

RC-PLANET Plant Life Cycle Management RC-PLANET Interface

Planet GmbH D-44357 Dortmund www.rc-planet.net

MPDS4 PIPING DESIGN Interface between MPDS4 PIPING DESIGN and the ROHR2 pipe stress analysis software. The interface allows piping data to be exported from MPDS4 for further processing in ROHR2.

CAD Schroer GmbH Fritz-Peters-Strasse 26-30 47447 Moers www.cad-schroer.de

UNITEC PCF4ROHR2 ROHR2 Interface - SIGMA ROHR2 (*.ntr) Integration

UNITEC Informationssysteme GmbH D-63457 Hanau-Wolfgang E-Mail [email protected] www.unitec.de

and various CAD-systems supporting PCF-format, e.g. I-Sketch or Solid Edge with iso.EDGE

Please note: the integration of external interfaces may require an upgrade/expansion of the program system ROHR2: the ROHR2 Neutral Interface is the main program module for the integration of CAD-programs (for details see 3.2).

SIGMA Ingenieurgesellschaft mbH www.rohr2.com