Test Report NO.:MZCBCSDA09406744a Date:Jan 30, 2015 Page 1 of 7
Applicant: Shenzhen Honcell Energy Co., Ltd. Address: 612, Bldg.A, Weidonglong Industrial Zone, Meilong Ave.194#,
Longhua New District, Shenzhen, China The following sample(s) was/were submitted and identified on behalf of the client as: Sample Name: Lithium-ion Polymer Battery Sample Model: HCP 402025 Manufacturer: SHENZHEN HONCELL ENERGY CO.,LTD. Parts Name: See next page Sample Received Date: Jan 27, 2015 Testing Period: Jan 27, 2015 To Jan 30, 2015 Reference Requested: RoHS Directive 2011/65/EU Annex Ⅱ Reference Method: 1.Review was performed for the samples disjionted from the submitted articles and the ralated test reports submitted by the Applicant 2.Tests was performed for the samples indicated by the photos in the report with
test methods reference to IEC62321 Edition 1.0 :2008:Procedures for the Determination of Levels of Six regulated substances in Electrotechnical products
(1) Screening by XRF Spectroscopy (2) Wet Chemical Test Method
a. Hexavalent Chromium Analysis is performed by Spot-test/Boiling-water-extraction Method
Test Result: Please refer to next page(s) Edited by: Checked by: Approved by:
Code:vcnf8u
Test Report NO.:MZCBCSDA09406744a Date:Jan 30, 2015 Page 2 of 7
Test Result (Unit:mg/kg)
EDXRF Chemical Testing Sample No. Part Name
Test Item Results(1) Test Item Result(2)(mg/kg) Limit Pb N.D. Pb / 1000 Cd N.D. Cd / 100 Hg N.D. Hg / 1000 Cr 253 Cr6+ / 1000
PBBs / 1000
A09406744-1
Battery sheath
Br N.D. PBDEs / 1000
Pb N.D. Pb / 1000 Cd N.D. Cd / 100 Hg N.D. Hg / 1000 Cr N.D. Cr6+ / 1000
PBBs / 1000
A09406744-2
Crepe Paper
Br N.D. PBDEs / 1000
Pb N.D. Pb / 1000 Cd N.D. Cd / 100 Hg N.D. Hg / 1000 Cr N.D. Cr6+ / 1000
PBBs / 1000
A09406744-3
insulating tape
Br N.D. PBDEs / 1000
Pb 142 Pb / 1000 Cd N.D. Cd / 100 Hg N.D. Hg / 1000 Cr 65.5 Cr6+ / 1000
PBBs / 1000
A09406744-4
Green Adhesive tape
Br N.D. PBDEs / 1000
Pb N.D. Pb / 1000 Cd 35.2 Cd / 100 Hg N.D. Hg / 1000 Cr N.D. Cr6+ / 1000
PBBs / 1000
A09406744-5
Yellow Adhesive tape
Br N.D. PBDEs / 1000
Test Report NO.:MZCBCSDA09406744a Date:Jan 30, 2015 Page 3 of 7
Test Result (Unit:mg/kg)
EDXRF Chemical Testing Sample No. Part Name
Test Item Results(1) Test Item Result(2)(mg/kg) Limit Pb 30.2 Pb / 1000 Cd N.D. Cd / 100 Hg N.D. Hg / 1000 Cr 31.1 Cr6+ / 1000
PBBs / 1000
A09406744-6
The positive electrode powder
Br N.D. PBDEs / 1000
Pb N.D. Pb / 1000 Cd N.D. Cd / 100 Hg N.D. Hg / 1000 Cr N.D. Cr6+ / 1000
PBBs / 1000
A09406744-7
Cathode powders
Br N.D. PBDEs / 1000
Pb N.D. Pb / 1000 Cd N.D. Cd / 100 Hg N.D. Hg / 1000
Cr 1.25×103 Cr6+ Negative See Note (2) (b)
PBBs / 1000
A09406744-8
The positive plate
Br / PBDEs / 1000
Pb 32.4 Pb / 1000 Cd N.D. Cd / 100 Hg N.D. Hg / 1000 Cr N.D. Cr6+ / 1000
PBBs / 1000
A09406744-9
Aluminum foil
Br / PBDEs / 1000
Pb N.D. Pb / 1000 Cd N.D. Cd / 100 Hg N.D. Hg / 1000 Cr N.D. Cr6+ / 1000
PBBs / 1000
A09406744-10
The negative plate
Br / PBDEs / 1000
Test Report NO.:MZCBCSDA09406744a Date:Jan 30, 2015 Page 4 of 7
Test Result (Unit:mg/kg)
EDXRF Chemical Testing Sample No. Part Name
Test Item Results(1) Test Item Result(2)(mg/kg) Limit Pb 20.7 Pb / 1000 Cd N.D. Cd / 100 Hg N.D. Hg / 1000 Cr N.D. Cr6+ / 1000
PBBs / 1000
A09406744-11
copper foil
Br / PBDEs / 1000
Test Report NO.:MZCBCSDA09406744a Date:Jan 30, 2015 Page 5 of 7
Remark
(1) (a) It is the result on total Br while test item on restricted substances is PBBs/PBDEs.It is the result on total Cr while test
item on restricted substances is Cr6+.
(b) Results are obtained by EDXRF for primary screening,and further chemical testing, if the concentration exceeds the
below warning value according to IEC 62321:2008(unit:mg/kg)
Element Polymer Metal Composite Materials
Cd BL≤(70-3σ)<X<(130+3σ)≤OL BL≤(70-3σ)<X<(130+3σ)≤OL LOD<X<(150+3σ)≤OL
Pb BL≤(700-3σ)<X<(1300+3σ)≤OL BL≤(700-3σ)<X<(1300+3σ)≤OL BL≤(500-3σ)<X<(1500+3σ)≤OL
Hg BL≤(700-3σ)<X<(1300+3σ)≤OL BL≤(700-3σ)<X<(1300+3σ)≤OL BL≤(500-3σ)<X<(1500+3σ)≤OL
Br BL≤(300-3σ)<X —— BL≤(250-3σ)<X
Cr BL≤(700-3σ)<X BL≤(700-3σ)<X BL≤(500-3σ)<X
(c) OL=Over Limit, BL=Below Limit, IN=Inconclusive, LOD=Limit of Detection
(d) The XRF screening test for RoHs elements-The reading may be different to the actual content in the sample be of
non-uniformity composition
(2) (a) mg/kg=ppm=0.0001%, N.D.= not detected(<MDL), ——= not conducted, /= not available.
(b) Spot-test:
Negative = Not Detected of CrVI coating, Positive = Presence of CrVI coating;
(The tested sample should be further verified by boiling-water-extraction method if the spot test result cannot be
confirmed or negative)
Boiling-water-extraction:
Negative = Not Detected of CrVI coating
Positive = Presence of CrVI coating; the detected concentration in boiling-water-extraction solution is equal
or greater than 0.02 mg/kg with 50cm2 sample surface area used.
Storage conditions and production date of the tested sample are unavailable and thus results of CrⅥ represent status
of the sample at the time of testing.
(3) As specified by client, to test the specified materials only.
(4) The original report which report No. is MZCBCSDA09406744 be replaced by this report, and it will be canceled
immediately and doesn’t have any legal validity. Please compliance with this report. Mar 10, 2015
Test Report NO.:MZCBCSDA09406744a Date:Jan 30, 2015 Page 6 of 7
Measurement Flow-chart Of Chemical Testing
Tested by:Chen Li Checked by:Mao Zuqing Person in charge of the lab by:Zhao Yanyuan These Samples Were Dissolved Totally By Pre-conditioning Method According To Below Flow Chart. (Cr6+ And PBBs/PBDEs Test Method Excluded)
Sample Preparation
Sample Measurement
Pb/Cd/Hg PBBs/PBDEs Cr6+
Acid digestion with microwave/hotplate
Filtration
Solution Residue
dissolved totally
AAS/ICP-OES
DATA
Sample solvent extraction
Concentration/ Dilution
Filtration
GC-MS
DATA
Nonmetallic material
Metallic material
Adding extraction solution
Boiling water extraction
Spot test
Heating to 90-95 for ℃extraction
Filtration and pH
Filtration and pH
adjustment
Adding 1,5- diphenylcarbazi
de for color development
UV-Vis
DATA
Negative
Positive
Test Report NO.:MZCBCSDA09406744a Date:Jan 30, 2015 Page 7 of 7
Sample No. & Photo:
Pony authenticate the photo on original report only
***End of Report***