Thanks to our R&D, we have developed an ultra-compact range, with the highest standards of efficiency and the level of sustainability associated with Hitecsa.
COMPACT, EFFICIENTAND SUSTAINABLE
__________________________________________________________________________________
ROOF TOP AIR-AIR
__________________________________________________________________________________
ADVANTAGES OF THE HITECSA ROOF TOP RANGE
Autonomous, compact units specially designed for installation on rooftops, roof terraces or in any other outdoor location. Air distribution is channelled through ducts.
Flexible and adaptable solutions for any project, thanks to its rooftop installation, its extracompact design and its weather resistant structure.
HIGHLY VERSATILE
INSTALLATION AND OPERATION
Roof Top units are the best technical solution to meet the needs of medium and large size areas with regards to comfort, air quality and energy efficiency.
Large retail outlets, shopping centres, specialist retailers, airports, restaurants, shops, cinemas and theatres, industrial buildings, logistics centres, offices…
APPLICATIONS
Thermodynamic recovery option
Free cooling option
HIGHENERGY
EFFICIENCYAND LOW
CONSUMPTION
Scroll type compressors
High-efficiency Plug fan
HIGH ENERGY EFFICIENCY
Roof TopAir - Air
32018 General Catalogue
__________________________________________________________________________________
KUBIC HE ROOF TOP RANGE: HIGH EFFICIENCY
KUBIC HE
__________________________________________________________________________________
RCF ROOF TOP RANGE WITH THERMODYNAMIC OR ACTIVE RECOVERY
Heat recovery modules are innovative energy recovery and air renovation systems which allow us to recover part of the energy that would otherwise be lost. They also introduce purified and climatised renovation air, removing air pollutants.Through heat recovery we can increase both the power and the nominal and seasonal performance of the unit, maximising energy efficiency and reducing operational costs.
EFFICIENCY AND AIR QUALITY IN THE INSTALLATIONS
Roof Top Air - Air Units Power kW
RMXRBA HE
RXCBA RCF
RXCBA VRC
RMXCBA RCF
Reve
rsib
le
RMXCBA VRC
190 200 230 30020 30 40 50 60 70 80 100 135 150 160 170
High efficiency / Scroll compressors / Axial fan
Cooling recovery / Scroll compressors / Axial fan
Centrifugal return fan / Scroll compressors / Axial fan
Cooling recovery / Scroll compressors / Axial fan
Centrifugal return fan / Scroll compressors / Axial fan
Roof Top units include all the components for the heating, cooling, ventilation and filtering system for air renovation with a single power outlet.
KUBIC HE ROOF TOP SERIES INSTALLATION EXAMPLE
GUARANTEED MINIMUM SEASONAL CONSUMPTION
Autonomous UnitsAir - AirRoof TopAir - Air
4 2018 General Catalogue
ROOF TOP AIR-AIR UNITS | KUBIC HEAxial fans
RMXRBA HE
NEW
A different Roof Top unitThe units of the KUBIC HE series are autonomous Roof Top units of high efficiency especially designed for installation on rooftops, roof terraces or in any other outdoor location.________________________________________
MAIN FEATURES• Cooling capacities: from 39.5 to 218.5 kW • Heating capacities: from 42.4 to 226.7 kW• R-410A refrigerant• Tandem scroll compressors, especially designed for heat pump
applications; they provide very wide operational limits• EER: up to 3.17• COP: up to 3.41• Condenser hermetic EC axial fans, with aluminium blades designed
to produce low noise levels• Indoor Plug fan to maximise energy efficiency• Complete cabinet: built from galvanised steel plate with a
polymerised polyester resin finish (RAL 1013); high corrosion resistance and protection from the elements
• Magneto-thermal switches for protection • Extra-compact G2 filter• Condensation control by variator as standard.
________________________________________
APPLICATIONS• Specially designed to be installed outdoors (rooftops, roof terraces,
etc.) for large areas with air duct installation
________________________________________
ADVANTAGES
• High efficiency complying with the requirements established under Regulation 2281/2016 (Ecodesign, ErP Ready)
• Extra-compact unit: high versatility for both installation and operation, which can be adapted to each and every project
• Units will be delivered completely finished and tested, with the appropriate load of R-410A refrigerant for their correct operation
• Anti-vibration operation thanks to the internal damping system in each compressor and the assembly over the dampers in the chassis
________________________________________
AVAILABLE VERSIONS• Heat pump
________________________________________
REGULATION
See regulation and control on page 22.
Control as standard up to model 135.2:
TH TUNE
Control as standard starting from model 171.4:
PGD
Optional control:
1. HIGH-EFFICIENCY ROOF TOP RANGE
MINI PGD
Roof TopAir - Air
52018 General Catalogue
__________________________________________________________________________________
PLUG FAN AS STANDARD
__________________________________________________________________________________
AVAILABLE OPTIONAL FEATURES
• Greater energy efficiency • Lower consumption • Quieter • High pressures available • Low maintenance cost
• Freecooling, thermal or enthalpy control• Compressor soft-start• Air quality sensor• High-performance thermo-acoustic insulation• Compressor acoustic insulation• External pressure taps• Detector of dirty filters• Heating coils for backup and hot water• Electrical resistance to provide auxiliary heating• Thermal insulation Euroclass A1 (M0)• Copper-copper coils• Anti-corrosion treated coils• Condensation tray in outside section• G4, F6 to F9 combinable filters• Economiser• Protective grille in outdoor section exchangers• Smoke detection
• Only cooling configuration • Remote run/stop• Unit without thermostat• Ambient temperature or wall-mounted sensor• Return temperature sensor in duct• Centralised control for up to 100 units.• Centralised control for up to 300 units.• Operation without neutral• ModBus IP/RTU, BacNet IP, WebServer, etc. connections
(check chapter on thermostats)
As well as these options, please check with our Commercial Department for any other configuration or function not described as available.
1. HIGH-EFFICIENCY ROOF TOP RANGE
• Lower installation cost• Plug and play: the flow is adjusted to the installation• The flow can be modified on-site just by changing a
few parameters
Autonomous UnitsAir - Air
6 2018 General Catalogue
Roof TopAir - Air
__________________________________________________________________________________
POSSIBLE AIR INLET/OUTLET CONFIGURATIONS
__________________________________________________________________________________
CONFIGURATION EXAMPLES
DISCHARGE CONFIGURATIONS
RETURN CONFIGURATIONS
NEW AIR DAMPER CONFIGURATIONS
Lower
Lower + upper front
F: new air damper / R: return air damper.
*For specific configurations, consult the Technical Department.
Upper + lower front Upper + lower Front Side
Upper Side
R
R R
RR
FF
F
F
F
Lower Upper Right side Upper frontLeft side Lower front
ECONOMISING CONFIGURATIONS
Lower Upper Right side Upper frontLeft side Upper front
DISCHARGE/RETURN
Any combination of discharge and return is valid, taking into account
that there can only be one discharge and one return.
DISCHARGE/NEW AIR
Any combination of discharge and return is valid, taking into account that there can only be one discharge, one return and one
new-air damper.
DISCHARGE/ECONOMISER
Any combination of discharge and economiser configuration is valid, taking into account that there can only be one
discharge and two dampers.
KUBIC HE
1. HIGH-EFFICIENCY ROOF TOP RANGE
Roof TopAir - Air
72018 General Catalogue
RMXRBA HE SERIESMODEL 40.3 45.3 57.3 71.3 77.3 114.2 125.2 135.2 171.4 200.4 219.4
COOLING MODE (1)
Nominal cooling capacity kW 39.5 45.2 57.2 71.0 76.9 113.6 125.3 134.8 171.0 200.0 218.5
Nominal cooling consumption kW 16.4 18.7 23.7 29.4 31.9 39.5 44.4 49.9 53.9 69.1 77.8
EER 2.41 2.41 2.41 2.41 2.41 2.88 2.82 2.70 3.17 2.89 2.81
SEER 3.41 3.33 3.27 3.13 3.13 3.29 3.20 3.01 4.18 3.59 3.49
ŋs, c % 133.5 130.3 127.6 122.4 122.4 128.8 125.0 117.5 164.2 140.4 136.6
HEATING MODE (2)Nominal heating capacity kW 42.4 49.3 58.2 76.0 83.7 119.1 132.7 143.0 169.8 205.7 226.7
Nominal heating consumption kW 12.4 14.5 18.1 25.2 27.8 35.6 41.4 45.8 49.8 63.3 70.6
COP 3.41 3.41 3.21 3.01 3.01 3.35 3.21 3.12 3.41 3.25 3.21
SCOP 2.99 2.95 2.97 2.95 2.95 3.00 2.98 2.96 3.12 3.00 2.96
ŋs, h % 116.4 115.1 115.9 115.1 115.1 117.2 116.1 115.4 121.7 117.1 115.5
COMPRESSORSCOMPRESSOR TYPES Scroll
Number of compressors 3 2 4
Number of circuits 2
Gas Type R-410A
PCA 2088
Refrigerant Total Load kg 11.0 11.7 14.0 16.5 17.7 31.0 32.0 33.0 57.0 64.0 66.0
INDOOR FANType Plug fan with EC motor
Number 2 3
Nominal airflow m3/h 9,000 10,200 11,500 14,000 15,500 21,000 23,000 25,000 28,500 34,000 37,000
Available Static Pressure Pa 150 200 200 200 200 250 300 300 350 350 350
OUTDOOR FANType Axial
Number 2 4
Airflow m3/h 27,300 27,200 33,100 32,900 32,800 46,600 60,100 60,100 76,200 76,100 76,100
Available Static Pressure Pa 0 0 0 0 0 0 0 0 0 0 0
Diameter mm 710 710 800 800 800 800 800 800 800 800 800
Maximum power input kW 2 x 1.25 2 x 2.06 4 x 2.06
Maximum current input A 2 x 3 2 x 3.8 4 x 3.8
ELECTRICAL WIRINGSupply Voltage v / Phases/ Hz 400/3+N/50
Maximum current input A 59 64 71 86 93 114 122 129 147 174 193
LRA A 138 184 191 215 254 280 326 333 318 353 377
DIMENSIONS AND WEIGHTLength mm 2,910 3,900 4,330
Width mm 2,220 2,220 2,220
Height mm 1,300 1,900 2,240
Weight (standard unit without refrigerant load) kg 1,080 1,087 1,155 1,169 1,217 1,594 1,704 1,721 2,454 2,624 2.628
NOISE LEVELNoise Level dB(A) 86.0 86.3 85.9 87.2 88.3 89.4 91.2 91.9 89.2 92.8 94.2
Sound Pressure (5m) dB(A) 64.5 64.8 64.4 65.7 66.8 68.0 69.8 70.4 67.7 71.3 72.7
(1) Nominal cooling capacity calculated in accordance with standard EN-14511-2018 with indoor temperature conditions of 27°C. 19°C (wet bulb) and outdoor temperature of 35°C.Nominal cooling consumption for the complete unit (compressors and fan) in nominal conditions. calculated in accordance with standard EN-14511-2018.Seasonal cooling energy efficiency factor (SEER) calculated in accordance with standard EN-14825-2016.Seasonal cooling of areas energy efficiency (ηs.c) calculated according to Regulation (EU) 2016/2281.(2) Nominal heating capacity calculated in accordance with standard EN-14511-2018 with indoor temperature conditions of 20°C and outdoor temperature of 7°C. 6°C (wet bulb).Nominal heating consumption for the complete unit (compressors and fan) in nominal conditions. calculated in accordance with standard EN-14511-2018.Seasonal heating energy efficiency factor (SCOP) calculated in accordance with standard EN-14825-2016.Seasonal heating of areas energy efficiency (ηs.c) calculated according to Regulation (EU) 2016/2281.
1. HIGH-EFFICIENCY ROOF TOP RANGE
Autonomous UnitsAir - AirRoof TopAir - Air
8 2018 General Catalogue
ROOF TOP AIR - AIR UNITS | RCF | RCF MTQAxial fans
RMXCBA RCFHeat pump
2. RCF ROOF TOP RANGE
A different Roof Top unitThe units of the KUBIC RCF series are Roof Top units with heating cooling recovery and thermal freecooling as standard, especially designed for installation on rooftops, roof terraces or in any other outdoor location.________________________________________
MAIN FEATURES• Cooling capacities: from 64 to 308.4 kW • Heating capacities: from 67.4 to 304 kW• R-410A refrigerant• Scroll compressors, specially designed for heat pump
applications; they provide very wide operational limits• EER: up to 3.52• COP: up to 4.12• Condenser hermetic axial fans, with aluminium blades designed to
produce low noise levels• Cabinet: built from galvanised steel plate with a polymerised
polyester resin finish (RAL 1013); high corrosion resistance and protection from the elements
• Thermal freecooling
________________________________________
APPLICATIONS• Specially designed to be installed outdoors (rooftops, roof terraces,
etc.) for large areas with air duct installation
________________________________________
ADVANTAGES
• Extra-compact unit: high versatility for both installation and operation, which can be adapted to each and every project
• Units will be delivered completely finished and tested, with the appropriate load of R-410A refrigerant for their correct operation
• Anti-vibration operation thanks to the internal damping system in each compressor and the assembly over the dampers in the chassis
________________________________________
AVAILABLE VERSIONS• Heat pump• RCF MTQ: version with gas burner
________________________________________
REGULATION
See regulation and control on page 22.
Controls available:PGD MINI PGD
Roof TopAir - Air
92018 General Catalogue
2. RCF ROOF TOP RANGE
__________________________________________________________________________________
AVAILABLE OPTIONAL FEATURES
__________________________________________________________________________________
AVAILABLE VERSIONS
OPTIONAL FEATURES: PLUG FAN FOR DISCHARGE AND/OR RETURN
• Greater energy efficiency • Lower consumption • Quieter • High pressures available • Low maintenance cost• Lower installation cost• Plug and play: the flow is adjusted to the installation• The flow can be modified on-site just by changing a few parameters
MORE OPTIONS
• Enthalpy freecooling• Compressor soft-start• Air quality sensor• High-performance thermo-acoustic insulation• Compressor acoustic insulation• External pressure taps• Detector of dirty filters• Motor protection by means of magneto-thermal switches• Overpowered indoor ventilation group for higher
pressure• Heating coils for backup and hot water• Electrical resistance to provide auxiliary heating• Thermal insulation Euroclass A1 (M0)• Copper-copper coils• Anti-corrosion treated coils• Proportional condensation control through the axial fans
speed shifter• Condensation tray in outside section
• Cooling only configuration • G4, F6 to F9 combinable filters• Economiser• Protective grille in outdoor section exchangers• Smoke detection• Remote run/stop• Unit without thermostat• Ambient temperature or wall-mounted sensor• Return temperature sensor in duct• Centralised control for up to 100 units• Centralised control for up to 300 units• Operation without neutral• ModBus IP/RTU, BacNet IP, WebServer, etc. connections
(check chapter on thermostats)
As well as these options, please check with our Commercial Department for any other configuration or function not described as available.
The thermodynamic recovery module includes an additional circuit which operates at high cooling capacities. This circuit uses the extraction air to recover part of the wasted heat. Through heat recovery we can increase both the power and the nominal and seasonal performance of the unit.
KUBIC RCF Roof top with thermodynamic recovery
The module with a gas burner is especially designed for the climate control of large areas in the industrial and commercial sectors, and in areas with extremely low temperatures.
KUBIC RCF MTQ Roof top with thermodynamic recovery and gas burner
Autonomous UnitsAir - Air
10 2018 General Catalogue
Roof TopAir - Air
The thermodynamic recovery module includes an additional circuit which operates at high cooling capacities.This circuit uses the extraction air to recover part of the wasted heat. Through heat recovery we can increase both the power and the nominal and seasonal performance of the unit.It is necessary to change to regulation µPC and PGD.
__________________________________________________________________________________
DESCRIPTION
__________________________________________________________________________________
POSSIBLE AIR INLET/OUTLET CONFIGURATIONS
KUBIC RCF
2. RCF ROOF TOP RANGE
RETURN SIDE CONFIGURATIONS
RETURN LOWER CONFIGURATIONS
R
RR
R
R R
I
I
I
I
I
IEX
EX EX EX
EX
FA
FA FA FA
FA
EX
FA
R
RR
R
R R
I
I
I
I
I
IEX
EX EX EX
EX
FA
FA FA FA
FA
EX
FA
R
RR
R
R R
I
I
I
I
I
IEX
EX EX EX
EX
FA
FA FA FA
FA
EX
FA
R
RR
R
R R
I
I
I
I
I
IEX
EX EX EX
EX
FA
FA FA FA
FA
EX
FA
LOWER DISCHARGE
LOWER DISCHARGE
UPPER DISCHARGE
UPPER DISCHARGE
SIDE DISCHARGE
SIDE DISCHARGE
R
RR
R
R R
I
I
I
I
I
IEX
EX EX EX
EX
FA
FA FA FA
FA
EX
FA
R
RR
R
R R
I
I
I
I
I
IEX
EX EX EX
EX
FA
FA FA FA
FA
EX
FA
I: DISCHARGER: RETURNFA: NEW AIREX: EXTRACTION AIR
Roof TopAir - Air
112018 General Catalogue
2. RCF ROOF TOP RANGE
SERIES KUBIC RCFMODEL 1402.2 1602.2 2002.2 2402.2 3002.2 3502.2 4002.2 4502.2 5002.4 (*) 6002.4 (*) 7002.4 (*)
CAPACITIESCooling capacities (1) kW 64.1 71.1 87.4 103.5 116.4 152.0 164.8 178.4 236.6 274.4 308.4
Cooling capacities (1) Ton 18.23 20.22 24.85 29.43 33.10 43.22 46.86 50.73 67.28 78.02 87.69
Power input (3) kW 20.3 23.9 26.8 34.4 41.6 49.7 55.7 63.1 67.3 81.3 104.9
EER coefficient 3.16 2.97 3.26 3.01 2.81 3.06 2.96 2.83 3.52 3.38 2.94
Heating capacities (2) kW 67.4 76.8 89.2 106.0 120.8 163.8 177.6 193.5 222.4 263.9 304.0
Heating capacities (2) Ton 19.16 21.84 25.36 30.14 34.35 46.58 50.50 55.02 63.24 75.04 86.44
Power input (3) kW 17.1 19.9 22.7 28.2 34.4 42.4 48.6 54.8 54.0 64.9 87.0
COP coefficient 3.94 3.85 3.92 3.76 3.51 3.86 3.66 3.53 4.12 4.07 3.49
REFRIGERANT CIRCUITType R-410A
Number of refrigerant circuits Unit 3 3 5
GWP (4) 2088
Load Kg 2x6.3+3.3 13.2+3.5 14+4 15.6+4 16+4.3 2x15.5+6 16.5+15.5+6 2x16.5+6.5 57 + 10 64 + 12 66 + 15
Environmental Impact Tn (CO² eq) 33.20 34.87 37.58 40.92 42.39 77.26 79.34 82.48 139.89 158.68 169.13
Number of stages Unit 3 5
ELECTRICAL SPECIFICATIONSPower Supply V / ~ / Hz 400 / 3+N / 50
Max current input A 59 67 73 99 118 147 157 172 225 265 311
Start-up current A 138 187 191 226 279 313 361 375 348 423 475
COMPRESSORType SCROLL
Quantity Unit 3 5
Oil type POE 160 SZ
OUTDOOR CIRCUIT FANType Axial fan
Quantity 2 4
Nominal air flow m³/h 31,724 39,332 46,556 60,088 76,100
Available static pressure Pa 0
Diameter mm 710 800 710 800
Power kW 1.25 / 0.97 1.9 / 1.2 1.25 / 0.97 1.9 / 1.2
Speed rpm 950 / 825 890 / 690 950 / 825 890/690
INDOOR CIRCUIT FANType Centrifugal Radial EC
Nominal air flow m³/h 9,000 10,200 11,500 14,000 15,500 21,000 23,000 25,000 28,500 34,000 37,000
Available static pressure Pa 100 125 125 150 350 350 350
Quantity / Size 15 / 15 2 x 15 / 11 2 x 18 / 18 3 x 560 3 x 560 3 x 560
Power kW 1.5 2.2 2.2 4 4 5.5 5.5 7.5 3 x 3.4 3 x 3.4 3 x 5
Speed rpm 649 726 712 802 860 716 756 798 1,550 1,550 1,750
Condensate drain connection Ø 3/4” gas
RETURN CIRCUITNominal air flow m³/h 9,000 10,200 11,500 14,000 15,500 21,000 23,000 25,000 28,500 34,000 37,000
Available static pressure Pa 75 100 300
Quantity/Size 15 / 15 2 x 15 / 11 2 x 18/18 3 x 450 3 x 450 4 x 400
Power kW 1.5 2.2 2.2 4 5.5 4 5.5 5.5 3 x 3.6 3 x 5.2 4 x 5.6
Speed rpm 616 681 731 835 897 661 703 746 2,260 2,570 3,170
Condensate drain connection Ø 3/4" gas
DIMENSIONS AND WEIGHTLength mm 3,988 5,845 6,400
Width mm 2,219 2,219 2,219
Heigth mm 1,240 1,900 2,240
Weight kg 1,315 1,353 1,417 1,445 1,531 2,373 2,519 2,549 3,454 3,624 3,628
All data measured for a renewal flow of 90%. (1) Nominal cooling: Outdoor air temperature: 35 ºC. Indoor air wet temperature: 19 ºC. (2) Nominal pump: Outdoor air wet temperature: 6 ºC. Indoor air temperature 20 ºC. (3) Motorfans and compressors power input in nominal conditions. (4) Climatic warming potential of one kg of fluorinated greenhouse gas in relation to a kg of carbon dioxide over a period of 100 years. (5) The number of stages is increased by one with free-cooling (FC). (*): RMXCBA RCF 5002.4, 6002.4 and 7002.4 are equivalent to RMXRBA RCF HE 171.4, 200.4 and 219.4, respectively.
Autonomous UnitsAir - AirRoof TopAir - Air
12 2018 General Catalogue
ROOF TOP AIR-AIR UNITS | RCFAxial fans
RXCBA RCFHeat pump
Solutions for Roof Terraces with high flow rates, flexible and adaptable for each projectAutonomous compact Roof Top units with heating cooling recovery and thermal freecooling as standard, especially designed for installation on rooftops, roof terraces or in any other outdoor location with air distributed treated in ducts.________________________________________
MAIN FEATURES• Maximum cooling capacities ranging from 202.90 to 290.40 kW• Scroll compressor• Cabinet: built from galvanised steel plate corrosion resistant and
providing protection from the elements• Axial fans in outdoor section, prepared for outdoor installation• Centrifugal fans in indoor section with low noise level• Thermal freecooling
________________________________________
ADVANTAGES
• Maximum partialisation up to 9 stages depending on models• Optimised design for easy access to the main components,
facilitating maintenance tasks• Scroll compressors, specially designed for heat pump applications;
they provide very wide operational limits
________________________________________
AVAILABLE VERSIONS
• Heat pump
______________________________________
REGULATION
See regulation and control on page 22.
PGD MINI PGDControls available:
2. RCF ROOF TOP RANGE
Roof TopAir - Air
132018 General Catalogue
2. RCF ROOF TOP RANGE
__________________________________________________________________________________
FLEXIBILITY OF INSTALLATION RCF Standard
Optional
Any combination of discharge and return is valid, taking into account that there can only be one discharge and one return.
Extraction Return
Discharge
New air
RXCBA RCF SERIESMODEL 5002 6002CAPACITIES 20% air recovery
Total cooling capacity (1) kW 202.90 233.40
Cooling power input total (3) kW 65.45 77.80
EER coefficient 3.1 3.0
Total heating capacity (2) kW 202.90 233.90
Pump power input total (3) kW 59.68 70.88
COP coefficient 3.4 3.3
40% air recovery
Total cooling capacity (1) kW 223.75 261.90
Cooling power input total (3) kW 64.91 78.15
EER coefficient 3.4 3.4
Total heating capacity (2) kW 204.10 235.20
Pump power input total (3) kW 61.78 70.25
COP coefficient 3.3 3.3
60% air recovery
Total cooling capacity (1) kW 244.60 290.40
Cooling power input total (3) kW 64.37 78.49
EER coefficient 3.8 3.7
Total heating capacity (2) kW 205.30 236.70
Pump power input total (3) kW 58.66 69.62
COP coefficient 3.5 3.4
90% air recovery
Total cooling capacity (1) kW 237.40 272.10
Cooling power input total (3) kW 71.94 85.03
EER coefficient 3.3 3.2
Total heating capacity (2) kW 222.50 257.00
Pump power input total (3) kW 57.05 69.46
COP coefficient 3.9 3.7
Cooling energy classification (4) A B
Heating energy classification (4) B B
Airflow m3/h 28,100 32,800
Discharge pressure available Pa 150 175
Return pressure available Pa 85 100
Power supply (50 Hz ~) V 400.3 + N 400.3 + N
Dimensions (length x width x height) mm 4,800 x 2,100 x 2,760 4,800 x 2,100 x 2,760
Net weight kg 3,450 3,480
(1) Nominal cooling conditions: outside air temperature: 35 0C. Return temperature 27 0C (dry bulb) / 19 0C (wet bulb).(2) Nominal heating conditions: outdoor air temperature 7 0C (dry bulb) / 6 0C (wet bulb). Return temperature 20 0C.(3) Total power input for compressors (not taking in to account ventilation)(4) According to the Eurovent energy classification.
Autonomous UnitsAir - Air
14 2018 General Catalogue
Roof TopAir - Air
__________________________________________________________________________________
AVAILABLE OPTIONAL FEATURES
ENERGY SAVING• Enthalpy freecooling• Compressor soft-start• Soft-start of the indoor and/or outdoor fan• Condensation control by voltage converter• Heat recovery of cooling units (R-404, etc.)• EC indoor plug fan• EC type axial fans
AIR QUALITY• Gravimetric filter in return G4 • Opacimetric filter in return class F6 to F9
(combinable with a G4 or Fx+Fy)• Outdoor model for on-rail F filters
NOISE LEVEL• Double thermo-acoustic insulation• Compressor acoustic insulation• Low noise outdoor fan section
UNIT INSTALLATION• Magneto-thermal switches in the electrical panel• Power supply at 60 Hz and voltages of 230, 208, etc.• Option of manufacturing units with symmetric
configuration• Pressure motors• Anti-freeze resistance operation in collection tray• Lower indoor air discharge• Upper indoor air return• Thermo-acoustic insulation• Hot gas bypass• Heating coils for hot water • Electric resistance coils for auxiliary electric heating• Anti-corrosion treated coils• Fireproof filter class M1
• Cooling only configuration • Thermal insulation Euroclass A1 (M0)• Condensation fan with pressure available• Condensation tray in outside section• Protective grille in outdoor section exchangers• Drip separator
MAINTENANCE• Service valves• Pressure gauges outdoors to read pressures• External pressure taps • Detector of dirty filters
REGULATION AND CONTROL • PGD and Mini PGD thermostat • Alarm signalling• Smoke detection• Remote run/stop• Separate electrical panel• Unit without thermostat• Option for master-slave operation • Ambient temperature or wall-mounted sensor• Return temperature sensor in duct• Air quality sensor• Operation for redundant machine• Centralised comprehensive management operation• Operation without neutral• Scheduling function and Modbus connection, etc.
(refer to the Thermostats chapter)
As well as these options, please check with our Commercial Department for any other configuration or function not described as available.
2. RCF ROOF TOP RANGE
152018 General Catalogue
Roof TopAir - Air
ROOF TOP AIR - AIR UNITS | VRC | VRC MTQ Centrifugal fans
3. VRC ROOF TOP RANGE
RMXCBA VRCHeat pump
A different Roof Top unitThe units of the KUBIC VRC series are Roof Top units with centrifugal return fan and thermal freecooling as standard, especially designed for installation on rooftops, roof terraces or in any other outdoor location.________________________________________
MAIN FEATURES• Cooling capacities: from 48.2 to 141.2 kW • Heating capacities: from 48.4 to 150.4 kW• R-410A refrigerant• Scroll compressors, specially designed for heat pump applications;
they provide very wide operational limits• Condenser axial fans, hermetic, comprising aluminium blades,
designed to produce low noise levels• Cabinet: built from galvanised steel plate with a polymerised
polyester resin finish (RAL 1013); high corrosion resistance and protection from the elements
• Thermal freecooling
________________________________________
APPLICATIONS• Specially designed to be installed outdoors (rooftops, roof terraces,
etc.) for large areas with air duct installation
________________________________________
ADVANTAGES
• Extra-compact unit: high versatility for both installation and operation, which can be adapted to each and every project
• Units will be delivered completely finished and tested, with the appropriate load of R-410A refrigerant for their correct operation
• Anti-vibration operation thanks to the internal damping system in each compressor and the assembly over the dampers in the chassis
________________________________________
AVAILABLE VERSIONS• Heat pump• VRC MTQ: version with gas burner
________________________________________
REGULATION
See regulation and control on page 22.
Controls available:PGD MINI PGD
Autonomous UnitsAir - Air
16 2018 General Catalogue
Roof TopAir - Air 3. VRC ROOF TOP RANGE
• Enthalpy freecooling• Compressor soft-start• Air quality sensor• High-performance thermo-acoustic insulation• Compressor acoustic insulation• External pressure taps• Detector of dirty filters• Motor protection by means of magneto-thermal switches• Overpowered indoor ventilation group for higher
pressure• Heating coils for backup and hot water• Electrical resistance to provide auxiliary heating• Thermal insulation Euroclass A1 (M0)• Copper-copper coils• Anti-corrosion treated coils• Proportional condensation control through the axial fans
speed shifter• Condensation tray in outside section• G4, F6 to F9 combinable filters
• Cooling only configuration • Economiser• Protective grille in outdoor section exchangers• Smoke detection• Remote run/stop• Unit without thermostat• Ambient temperature or wall-mounted sensor• Return temperature sensor in duct• Centralised control for up to 100 units• Centralised control for up to 300 units• Operation without neutral• ModBus IP/RTU, BacNet IP, WebServer, etc. connections
(check chapter on thermostats)
As well as these options, please check with our Commercial Department for any other configuration or function not described as available.
The VRC module allows us to manage different discharge flow renovation percentages. Furthermore, its section combines three dampers and this allows to manage freecooling, whether with thermal, enthalpy or thermo-enthalpy.
KUBIC VRC Roof top withcentrifugal return fan
The module with a gas burner is is especially designed for the climate control of large areas in the industrial and commercial sectors, and in areas with extremely low temperatures.
KUBIC VRC MTQ Roof top with centrifugal return fan and gas burner
__________________________________________________________________________________
AVAILABLE VERSIONS
__________________________________________________________________________________
AVAILABLE OPTIONAL FEATURES
OPTIONAL FEATURES: PLUG FAN FOR DISCHARGE AND/OR RETURN
MORE OPTIONS
• Greater energy efficiency • Lower consumption • Quieter • High pressures available • Low maintenance cost• Lower installation cost• Plug and play: the flow is adjusted to the installation• The flow can be modified on-site just by changing a few parameters
Roof TopAir - Air
172018 General Catalogue
3. VRC ROOF TOP RANGE
The VRC module allows to manage different discharge flow renovation percentages.Its combined section with three dampers also allows managing freecooling, whether with thermal, enthalpy or thermo-enthalpy.It is necessary to change to regulation µPC and PGD.
__________________________________________________________________________________
DESCRIPTION
KUBIC VRC
__________________________________________________________________________________
POSSIBLE AIR INLET/OUTLET CONFIGURATIONS
RETURN SIDE CONFIGURATIONS
RETURN LOWER CONFIGURATIONS
R
RR
R
R R
I
I
I
I
I
IEX
EX EX EX
EX
FA
FA FA FA
FA
EX
FA
R
RR
R
R R
I
I
I
I
I
IEX
EX EX EX
EX
FA
FA FA FA
FA
EX
FA
R
RR
R
R R
I
I
I
I
I
IEX
EX EX EX
EX
FA
FA FA FA
FA
EX
FA
I: DISCHARGE R: RETURN FA: NEW AIR EX: EXTRACTION AIR
LOWER DISCHARGE
LOWER DISCHARGE
UPPER DISCHARGE
UPPER DISCHARGE
SIDE DISCHARGE
SIDE DISCHARGE
R
RR
R
R R
I
I
I
I
I
IEX
EX EX EX
EX
FA
FA FA FA
FA
EX
FA
R
RR
R
R R
I
I
I
I
I
IEX
EX EX EX
EX
FA
FA FA FA
FA
EX
FA
R
RR
R
R R
I
I
I
I
I
IEX
EX EX EX
EX
FA
FA FA FA
FA
EX
FA
Autonomous UnitsAir - Air
18 2018 General Catalogue
Roof TopAir - Air
KUBIC VRC SERIESMODEL 1402.2 1602.2 2002.2 2402.2 3002.2 3502.2 4002.2 4502.2CAPACITIESCooling capacity (1) kW 48.2 54.9 68.0 82.8 91.0 118.7 131.1 141.2
Power input (3) kW 17.2 21.4 23.2 30.8 36.5 43.3 49.3 55.7
EER coefficient 2.80 2.56 2.93 2.69 2.49 2.74 2.66 2.53
Heating capacity (2) kW 48.4 56.7 67.3 83.2 93.3 121.2 137.3 150.4
Power input (3) kW 14.9 18.8 19.9 27.0 31.5 39.4 46.5 51.9
COP coefficient 3.24 3.01 3.38 3.09 2.96 3.08 2.95 2.90
REFRIGERANTSType R-410A
PCA (4) 1720
Load kg 12.5 13.2 14 15.6 16 31 32 33
COMPRESSORType Scroll
Number 2
Number of cooling circuits 2
Number of stages (5) 2
Oil type POE 160 SZ
OUTSIDE CIRCUIT FANType Outdoor axial rotor
Number 2 4
Nominal airflow m³/h 31,724 31,724 39,332 39,332 39,332 39,332 60,088 60,088
Available static pressure Pa 0
Diameter mm 710 800 710
Power kW 1.25/0.97 2.06/1.33 1.25/0.97
Speed rpm 950/825 890/690 950/825
INDOOR CIRCUITNominal airflow m³/h 9,000 10,200 11,500 14,000 15,500 21,000 23,000 25,000
Available static pressure Pa 100 100 125 125 125 150 150 150
Quantity/Dimensions 15/15 2x15/11 2x18/18
Power kW 1.5 2.2 2.2 4 5.5 4 5.5 5.5
Speed rpm 616 677 712 802 860 642 673 707
Condensate evacuation Ø Junction 3/4” M
RETURN CIRCUITNominal airflow m³/h 9,000 10,200 11,500 14,000 15,500 21,000 23,000 25,000
Available static pressure Pa 75 75 100 100 100 100 100 100
Quantity/Dimensions 15/15 2x15/11 2x18/18
Power kW 1.5 2.2 2.2 3 4 4 4 5.5
Speed rpm 575 604 602 686 742 568 603 637
Condensate evacuation Ø Junction 3/4” M
ELECTRICAL SPECIFICATIONSPower supply 400V - 3N 50Hz
DIMENSIONSLength mm 3,988 5,845
Width mm 2,219 2,219
Height mm 1,240 1,900
Weight kg 1,233 1,265 1,347 1,376 1,442 2,238 2,380 2,405
All the data have been measured for an air renovation flow of 25%.(1) Nominal cooling conditions: outside air temperature: 35 0C. Return temperature 27 0C (dry bulb) / 19 0C (wet bulb).(2) Nominal heating conditions: outdoor air temperature 7 0C (dry bulb) / 6 0C (wet bulb). Return temperature 20 0C.(3) Climate warming potential of a kg of fluorinated greenhouse gas in relation to a kg of carbon dioxide gas over a period of 100 years.(4) The number of stages increases with freecooling (FC).
192018 General Catalogue
Roof TopAir - Air
ROOF TOP AIR-AIR UNITS | VRCAxial fans
RXCBA VRCHeat pump
Solutions for Roof Terraces with high flow rates, flexible and adaptable for each projectAutonomous compact Roof Top units with centrifugal return fan and thermal freecooling as standard, especially designed for installation on rooftops, roof terraces or in any other outdoor location with air distributed treated in ducts.________________________________________
MAIN FEATURES• Maximum cooling capacities ranging from 162 to 192.3 kW• Scroll compressor• Cabinet: built from galvanised steel plate corrosion resistant and
providing protection from the elements• Axial fans in outdoor section, prepared for outdoor installation• Centrifugal fans in indoor section with low noise level• Thermal freecooling
________________________________________
ADVANTAGES
• Maximum partialisation up to 9 stages depending on models• Optimised design for easy access to the main components,
facilitating maintenance tasks• Scroll compressors, specially designed for heat pump applications;
they provide very wide operational limits
________________________________________
AVAILABLE VERSIONS
• Heat pump
______________________________________
REGULATION
See regulation and control on page 22.
PGDControls available:
MINI PGD
Autonomous UnitsAir - Air
20 2018 General Catalogue
Roof TopAir - Air
RXCBA VRC SERIESMODEL 5002 6002Nominal cooling capacity (1) kW 162.0 192.3
Nominal heating capacity (2) kW 167.8 199.4
Power supply (50 Hz ~) V 400.3 + N 400.3 + N
EER 2.81 2.81
COP 3.23 3.21
Cooling energy classification (3) B B
Heating energy classification (3) B B
Airflow m3/h 28,100 32,800
Available static pressure (discharge) Pa 150 175
Available static pressure (return) Pa 85 100
Dimensions (length x width x height) mm 4,800 x 2,100 x 2,760 4,800 x 2,100 x 2,760
Net weight kg 3,289 3,308
(1) Nominal cooling conditions: outdoor air temperature: 35 ºC. Return temperature 27 ºC (dry bulb) / 19 ºC (wet bulb). (2) Nominal heating conditions: outdoor air temperature 7 ºC (dry bulb) / 6 ºC (wet bulb). Return temperature 20 ºC. (3) According to the Eurovent energy classification.
__________________________________________________________________________________
FLEXIBILITY OF INSTALLATION VRC Standard
Optional
Any combination of discharge and return is valid, taking into account that there can only be one discharge and one return.
Extraction Return
Discharge
New air
Roof TopAir - Air
212018 General Catalogue
__________________________________________________________________________________
AVAILABLE OPTIONAL FEATURES
ENERGY SAVING• Enthalpy freecooling• Compressor soft-start• Soft-start of the indoor and/or outdoor fan• Condensation control by voltage converter• Heat recovery of cooling units (R-404, etc.)• EC indoor plug fan• EC type axial fans
AIR QUALITY• Gravimetric filter in return G4 • Opacimetric filter in return class F6 to F9
(combinable with a G4 or Fx+Fy)• Outdoor model for on-rail F filters
NOISE LEVEL• Double thermo-acoustic insulation• Compressor acoustic insulation
• Low noise outdoor fan section
UNIT INSTALLATION• Magneto-thermal switches in the electrical panel• Power supply at 60 Hz and voltages of 230, 208, etc.• Option of manufacturing units with symmetric
configuration• Pressure motors• Anti-freeze resistance operation in collection tray• Lower indoor air discharge• Upper indoor air return• Thermo-acoustic insulation• Hot gas bypass• Heating coils for hot water • Electric resistance coils for auxiliary electric heating• Anti-corrosion treated coils• Fireproof filter class M1
• Cooling only configuration • Thermal insulation Euroclass A1 (M0)• Condensation fan with pressure available• Condensation tray in outside section• Protective grille in outdoor section exchangers• Drip separator
MAINTENANCE• Service valves• Pressure gauges outdoors to read pressures• External pressure taps • Detector of dirty filters
REGULATION AND CONTROL • PGD and Mini PGD thermostat• Alarm signalling• Smoke detection• Remote run/stop• Separate electrical panel• Unit without thermostat• Option for master-slave operation • Ambient temperature or wall-mounted sensor• Return temperature sensor in duct• Air quality sensor• Operation for redundant machine• Centralised comprehensive management operation• Operation without neutral• Scheduling function and Modbus connection, etc.
(refer to the Thermostats chapter)
As well as these options, please check with our Commercial Department for any other configuration or function not described as available.
Autonomous UnitsAir - Air
22 2018 General Catalogue
Roof TopAir - Air
__________________________________________________________________________________
CONTROLS AVAILABLE FOR ROOF TOP
• Operating modes: ventilation, cooling, heating and auto. • Thermostat comprising a user interface terminal installed in the environment, and an
input and output board (PCO3 or µPC) located on the outdoor unit. • Display of operating mode, programmed temperature, ambient temperature, days of
the week, mode, setpoints, alarms, etc. • Control of 2 electric resistance stages, heat valve and gas burner module. • Modification of the operating parameters. • Program weekly timetable. Timetable phase mode. • Codes to Identify alarm types. • May be used as a central control for up to 15 machines.• Three levels of access for modifying parameters: user, maintenance and manufacturer.• Alarms history.
PGD Controller
• Completely compatible with all the software applications and hardware designed by PGD, with a resolution of 132x64 pixels.
• Allows icons (defined at the application software-development level) to be viewed, and two-tier international sources to be handled, as well as allowing navigation of the screen using 6 buttons and a buzzer to produce an acoustic warning.
Mini PGD Controller
• Thermostat comprising a user interface terminal installed in the environment, and an input and output board (µPC) located on the outdoor unit.
• Operating modes: ventilation, cooling, heating and auto. • Control sensor in return (remote): optional.• Display of operating mode, programmed temperature, ambient temperature, days of
the week, mode, fan speed, setpoints, alarms, etc. • Program weekly timetable. Timetable phase mode. • Codes to Identify alarm types.
TH-TUNE Thermostat (only for KUBIC HE)
Roof TopAir - Air
232018 General Catalogue
__________________________________________________________________________________
CENTRALISED MANAGEMENT SYSTEM AND BMS
Connection of several units using the pLAN network belonging to the PCO3 or µPC board. Each of the machines connected in a network can be accessed from a single PGD control. Up to a maximum of 15 units connected.
1...
1...
2...
2...
...15
...15
CENTRALISED CONTROL FOR UNITS WITH PGD CONTROL AND PCO3 or µPC BOARDS.
FOR ROOF TOP BIG (*):
FOR ALL OTHER ROOF TOP:
FOR ROOF TOP BIG (*):
FOR ALL OTHER ROOF TOP:
BMS connection with the following integration languages:ModBus – Lonworks – BacNet.Check for other integration languages.
CONNECTION OF SEVERAL UNITS WITH PCO3 or µPC CARDS VIA RS485 CARDS TOWARDS A SUPERVISION SYSTEM
Third-party BMS (not supplied by Hitecsa)
Third-party BMS (not supplied by Hitecsa)
• ModBus• Lonworks• BacNet
• ModBus• Lonworks• BacNet
(*) ROOF TOP BIG: RMXRBA 171.4 - 200.4 - 219.4 | RXCBA 5002 - 6002
Autonomous UnitsAir - Air
24 2018 General Catalogue
Roof TopAir - Air
• Monitoring functions with visual and graphic elements • User management for access control and operations registration • Management of configurable reports • Alarm management • Local and remote connectivity • Scheduling function • Energy saving management • Option of screen personalisation, emulating installation (SCADA) • Activity planning and controls for instruments or groups of instruments• Possibility of installing plugins with special functions
__________________________________________________________________________________
MAIN FEATURES
Screen with a complete alarm list (access depending on user level):
for viewing and resetting alarms.
Report management screen (access depending on user level):
allowing reports to be configured and produced, according to date
and chosen variables.
Screen with a complete parameter list (access depending on user level):
for reading/viewing values and for saving them (backup copy).
Maximum number of connected units according to model.
CUSTOMISABLE AND INTUITIVE INTERFACE
All the information is available to users in just two easy clicks. Including system configuration and device management.
__________________________________________________________________________________
(BMS) BOSS MONITORING SYSTEM
Carel supervision and monitoring system for controlling installations.All thermostats with ModBus output can be integrated via RS-485.• Standard: up to 100 units • Extended: up to 300 units
DESIGNED FOR MOBILE DEVICES
Completely accessible by mobile devices, from start up to daily access to the maintenance system;Integrated WI-FI to create a network and allow access to user devices without requiring other network infrastructure.
KUBIC HEACHIBA HE CHILLERS/HP VERNE
Roof TopAir - Air
252018 General Catalogue
__________________________________________________________________________________
NOTES
Autonomous UnitsAir - Air
26 2018 General Catalogue
Roof TopAir - Air
__________________________________________________________________________________
NOTES
Roof TopAir - Air
272018 General Catalogue
__________________________________________________________________________________
NOTES
www.hitecsa.com
HIPLUS AIRE ACONDICIONADO S.L.
Edificio “O” Complejo Miniparc IIC/ Calendula, 9528109 AlcobendasMadrid, SpainTel. +34 916 187 556
Masia Torrents, 208800 Vilanova i la GeltrúBarcelona, SpainTel. +34 938 934 912Fax +34 938 939 615
C/ Prudenci Rabell i Pubill, 3Polig. Ind. Valldegata Draper08350 Arenys de MarBarcelona, SpainTel. +34 937 957 996
Ctra. Sant Jaume dels Domenys, Km. 0.5Polig. Ind. Domenys I08720 Vilafranca del PenedèsBarcelona, SpainTel. + 34 938 934 912
05/2019