roofing and cladding profilesisk-wordpress.s3.us-east-1.amazonaws.com/vicwest_dev/wp...contact...

24
ROOFING AND CLADDING PROFILES Steel building envelope products that add beauty and durability to your designs BUILDING FOR TOMORROW INNOVATIVE. ADAPTABLE. ENERGY EFFICIENT.

Upload: others

Post on 18-Feb-2021

2 views

Category:

Documents


0 download

TRANSCRIPT

  • ROOFING AND CLADDING PROFILES

    Steel building envelope products that add beauty and durability to your designs

    BUILDING FOR TOMORROW

    INNOVATIVE. ADAPTABLE. ENERGY EFFICIENT.

  • 2 www.vicwest.com

    TABLE OF CONTENTS

    BELLARATM Mountain Cedar

    P.A.W. Pet and Wildlife Rescue Chatham, ONArchitects: ROA Studio Inc.

    Vicwest Profiles Introduction ............................................... 4

    Hidden Fastener Wall Profiles .............................................. 5

    Exposed Fastener Profiles ................................................. 6-9

    Perforated Wall Cladding ................................................... 10

    Roof System Profiles .......................................................... 11

    Roof & Floor Deck Profiles ................................................. 12

    Trims & Accessories ...................................................... 13-20

    AD300 Trims & Accessories ................................................ 21

    Sub-girts ............................................................................ 22

    Project Gallery ................................................................... 23

    Cover Image: École primaire du secteur C, Brossard, Quebec

  • 3BUILDING FOR TOMORROW

    Model Number Page1/2” CORRUGATED 87/8” CORRUGATED 8AD150 5AD200-R 5AD200-SR 5AD275-R 5AD275-SR 5AD300-R 5AD300-SR 5BELLARATM 5CHANNELWALL 6CL3035 6CL3070 6CL3100 7CL400 7CL4012 9CL435 6CL439 8CL470 6CL5022-SR 7CL508 6CL6025-SR 7CL622-R 7CL7015-R 6CL7040 7CL725-R 7CL815-R 6

    Model Number PageCL840 7CL938 8DR30 8DR36 8GRAND RIB 9HB306 12HB306-CL 12HB938 12HB938-CL 12HBS938 12HBS938-CL 12L800-R 9MARQUIS 450 11PRESTIGE 12” 11PRESTIGE-R 16” 11PRESTIGE-R 20” 11RD306 12RD306-CL 12RD938 12RD938-CL 12RDS938 12RDS938-CL 12SUPERVIC 9TRADITION 100-4 11TRADITION 150-4 11TSR 11ULTRAVIC 9

    INDEXProducts sorted alphabetically

    Our Promise to You: Vicwest will help you to create the most aesthetically pleasing, durable, innovative and sustainable structures possible.

    As your building partner, our goal is to provide you with a team of specialized professionals, services and tools that will assist you from project conception to completion.

    Our extensive line of Roofing and Cladding products provides you with the choice you desire in planning your project and the ability to make your vision a reality.

  • 4 www.vicwest.com

    Steel roof or wall claddings add style, beauty and character to your building’s design, regardless of size or shape.

    An array of product choices

    We offer a broad range of cladding options to help you customize your project from traditional profiles to clean modern lines, curves and innovative patterns. Your partners at Vicwest will help you to make the right choice of products to complete your project with strength and beauty.

    Lasting colours with a guaranteed warranty

    WeatherXL™ provides the ultimate in resistance to scratching and weathering. The enhanced SMP (Silicone Modified Polyester) paint system offers maximum hardness by acting as a shield against environmental elements to prevent chalking and fading while preserving its brilliant colour and gloss to insure your finished product remains beautiful for years to come. Our extensive colour choices are all supported by our 40 year limited warranty.

    Flashings, trims & accessories

    The finishing touches complete the look of your project and help to bring it all together. Our broad range of coordinating installation systems, trims, components and accessories are available in a multitude of standard and custom colours and finishes to complete your project with beauty and durability.

    Choose from our extensive line of building envelope products

    CL7040

    CL7040 MacBain Community Centre Niagara Falls, ON

    Architects: MacLennan Jaunkalns Miller

    Milton Sport Centre - Gymnastic Facility

    Milton, ONTillmann Ruth

    Robinson Architects

    7/8’’ CORRUGATED - Custom Colours Q PlexQuispamsis, NB

    Murdock & Boyd Architects

    VICWEST PROFILES

  • 5

    AD150

    1 9/16”(40 mm)

    5 29/32”(150 mm)

    5 29/32”(150 mm)

    Painted Side Painted Side

    AD200-R

    1 9/16”(40 mm)

    7 7/8” (200 mm)

    3 15/16” (100 mm)

    AD200-R is also available without stiffener ribsAD200-SR

    AD275-R is also available without stiffener ribsAD275-SR

    1 9/16”(40 mm)

    10 13/16”(275 mm)

    1” (25 mm)

    Painted Side

    AD275-R AD300-R

    AD300-R is also available without stiffener ribsAD300-SR

    1 9/16”(40 mm)

    11 13/16”(300 mm)

    Painted Side

    HIDDEN FASTENER WALL PROFILESR - Ribbed SR - No Rib

    BELLARATM STEEL SIDING

    5.25” (133.35 mm)

    .35” (9.04 mm)

    7.26” (184.4 mm)

    96˚

    141˚

    96 ˚

    .59”(15 mm)

    AD300-R Dark Cedar

    London Gymnastics AssociationArchitects: a+LINK Architecture Inc.

    Fassade System using 7/8” Corrugated and AD300-R (horizontal

    and vertical)

    Exposed side pre-painted(Dim.) = mm

    BUILDING FOR TOMORROW

  • 6 www.vicwest.com

    CL7015-R (CAN ONLY BE USED AS A WALL CLADDING)CL7015-R is the reverse of CL815-R

    29 3/4” (755 mm)

    4 1/4” (108 mm)

    9/16” (15 mm)

    Painted Side

    CL 3070

    CL3070 is the reverse of CL470

    2 3/4”(70 mm)

    11 5/32” (283 mm)

    33 7/16” (850 mm)Painted Side

    CL3070 (CAN ONLY BE USED AS A WALL CLADDING)

    CL3035 (CAN ONLY BE USED AS A WALL CLADDING)

    CL3035 is the reverse of CL435

    1 3/8” (35 mm)

    39 31/32” (1015 mm)

    13 5/16” (338 mm) Painted Side

    CL815-R (CAN ONLY BE USED AS A WALL CLADDING)

    29 3/4” (755 mm)

    4 1/4” (108 mm)

    9/16” (15 mm)

    Painted Side

    CL815-R is the reverse of CL7015-R

    CL470 (CAN BE USED FOR ROOF AND WALLS)

    CL470 is the reverse of CL3070

    2 3/4” (70 mm)

    33 7/16”(850 mm)

    Painted Side

    11 5/32” (283 mm)

    CL435 (CAN BE USED FOR ROOF AND WALLS)

    CL435 isthe reverseof CL3035

    1 3/8”(35 mm)

    39 31/32”(1015 mm)

    Painted Side

    13 5/16” (338 mm)

    EXPOSED FASTENER PROFILESCL - Cladding Lap R - Ribbed SR - No Rib

    **APPLICATION NOTE: Please consult your Vicwest representative for maximum length recommendations for this product.Exposed fastened roofs should be installed on slopes greater than 3:12. Please consult your Vicwest Representative for slopes lower than 3:12.

    CHANNELWALL is the reverse of CL508

    32” (813 mm)

    6 3/8” (162 mm)

    1/2” (13 mm)

    Painted Side

    CHANNELWALL (CAN ONLY BE USED AS A WALL CLADDING) CL508 (CAN ONLY BE USED AS A WALL CLADDING)

    CL508 is the reverse of CHANNELWALL

    32” (813 mm)

    6 3/8” (162 mm)

    1/2” (13 mm)

    Painted Side

    Exposed side pre-painted(Dim.) = mm

  • 7BUILDING FOR TOMORROW

    EXPOSED FASTENER PROFILES (continued)CL - Cladding Lap R - Ribbed SR - No Rib**APPLICATION NOTE: Please consult your Vicwest representative for maximum length recommendations for this product.Exposed fastened roofs should be installed on slopes greater than 3:12. Please consult your Vicwest Representative for slopes lower than 3:12.

    CL3100 (CAN ONLY BE USED AS A WALL CLADDING)

    CL3100 isthe reverse of CL400

    3 15/16”(100 mm)

    33 3/32”(840 mm)

    11 1/32” (280 mm)

    Painted Side

    CL400 (CAN BE USED FOR ROOF AND WALLS)

    CL400 is the reverse of CL3100

    3 15/16” (100 mm)

    33 3/32”(840 mm)

    11 1/32” (280 mm)

    Painted Side

    CL5022-SR (CAN ONLY BE USED AS A WALL CLADDING)CL5022 is thereverse of CL622

    Available with stiffener ribs CL5022-R

    37 3/8” (950 mm)

    7 1/2” (190 mm)

    1 3/8” (35 mm)

    Painted Side

    Minimum thickness required for CL5022-SRplease contact your Vicwest Sales Representative

    CL622-R (CAN BE USED FOR ROOF AND WALLS)CL622 is thereverse of CL5022

    CL622 is alsoavailable without stiffener ribsCL622-SR

    1 7/16”(36 mm)

    37 3/8” (950 mm)

    7 1/2” (190 mm)

    Painted Side

    Minimum thickness required for CL622-SRplease contact your Vicwest Sales Representative

    CL6025 is the reverse of CL725

    CL6025-SR (CAN ONLY BE USED AS A WALL CLADDING)

    Available with stiffener ribs CL6025-R

    35 7/16” (900 mm)

    1 7/16” (36 mm)

    5 7/8” (150 mm) Painted Side

    CL725-R (CAN BE USED FOR ROOF AND WALLS)CL725 is the reverse of CL6025CL725 is alsoavailable withoutstiffener ribsCL725-SR

    35 7/16”(900 mm)

    Painted Side

    5 7/8” (150 mm)1 7/16”(36 mm)

    CL7040 (CAN ONLY BE USED AS A WALL CLADDING)

    CL7040 is the reverse of CL840

    36 13/16” (935 mm)

    5 1/4” (134 mm)

    1 9/16” (40 mm)

    Painted Side

    CL840 (CAN BE USED FOR ROOF AND WALLS)

    CL840 isthe reverse of CL7040

    1 9/16” (40 mm)

    36 13/16” (935 mm)

    5 1/4” (134 mm) Painted Side

    Exposed side pre-painted(Dim.) = mm

  • 8 www.vicwest.com

    CL - Cladding Lap R - Ribbed SR - No Rib**APPLICATION NOTE: Please consult your Vicwest representative for maximum length recommendations for this product.Exposed fastened roofs should be installed on slopes greater than 3:12. Please consult your Vicwest Representative for slopes lower than 3:12.

    Standard for West region. Please verify the feasibility with Vicwest for Central, East and Maritime Regions.

    DR30 (CAN ONLY BE USED AS A WALL CLADDING)

    30” (762 mm)

    6” (152 mm)

    5/8” (16 mm)

    Painted Side

    DR36 (CAN ONLY BE USED AS A WALL CLADDING)

    36” (914 mm)

    6” (152 mm)

    5/8” (16 mm)

    Painted Side

    7/8” CORRUGATED (CAN BE USED FOR ROOF AND WALLS)

    7/8” (22 mm)

    2 5/8” (68 mm)

    34 1/2” (878 mm)

    Painted Side

    1/2” CORRUGATED (CAN BE USED FOR ROOF AND WALLS)

    1/2” (14 mm)

    29 11/32” (745 mm)

    2 11/16” (68 mm) Painted Side

    CL439 (CAN BE USED FOR ROOF AND WALLS)

    39 3/8” (1000 mm)

    1 3/8” (34 mm)

    13 1/8” (333 mm) Painted Side

    CL938 (CAN ONLY BE USED AS A WALL CLADDING)

    35 7/16” (900 mm)

    1 1/2”(38 mm)

    5 7/8”(150 mm)

    Standard for West region. Please verify the feasibility with Vicwest for Central, East and Maritime Regions.

    Roof: MARQUIS 450

    Virgil Fire Hall

    Niagara-on-the-Lake, ON Panici Architects

    EXPOSED FASTENER PROFILES (continued)Exposed side pre-painted(Dim.) = mm

  • 9BUILDING FOR TOMORROW

    CL - Cladding Lap R - Ribbed SR - No Rib**APPLICATION NOTE: Please consult your Vicwest representative for maximum length recommendations for this product.Exposed fastened roofs should be installed on slopes greater than 3:12. Please consult your Vicwest Representative for slopes lower than 3:12.

    Visit vicwest.com for more information and to view our complete line of metal building products

    CL4012 (CAN ONLY BE USED AS A WALL CLADDING)

    30” (762 mm)

    7 1/2” (190.5 mm)

    3/4” (19 mm)

    Painted Side

    CL4012 is the reverse of Grand Rib

    GRAND RIB (CAN BE USED FOR ROOF AND WALLS)

    30” (762 mm)

    7 1/2” (190.5 mm)

    3/4” (19 mm)

    Painted Side

    Grand Rib is the reverse of CL4012

    ULTRAVIC (CAN BE USED FOR ROOF AND WALLS)

    36” (914 mm)

    9” (228.6 mm)

    3/4” (19 mm)

    Painted Side

    SUPERVIC (CAN BE USED FOR ROOF AND WALLS)

    30” (762 mm)

    3/4”(19 mm)

    10” (254 mm) Painted Side

    Bella Concert Hall, Calgary, ABSahuri + Partners Architecture

    Walls: CL400

    L800-R LINER PANEL Component*

    31 1/2” (800 mm)6 19/64”

    (160 mm) Painted Side

    Available in L800-SR (without rib)

    * APPLICATION NOTE: L800 & L800-R are to be specified and installed as part of an interior component of a conventional wall or roof assembly only.

    EXPOSED FASTENER PROFILES (continued)Exposed side pre-painted(Dim.) = mm

  • 10 www.vicwest.com

    Contact Vicwest Representative for availability on specific profiles and open air percentage.

    PERFORATED WALL CLADDING

    STAGGERED LINE PATTERN

    Hole Size & Spacing % Open Air

    1/16 x 3/32 40.3

    .078 x 1/8 35.4

    1/8 x 3/16 40.3

    1/16 x 7/64 29.6

    3/32 x 5/32 32.7

    1/8 x 7/32 29.6

    3/32 x 3/16 22.7

    1/8 x 1/4 22.7

    1/8 x 0.379 9.9

    1/4 x 3/8 40.3

    STRAIGHT LINE PATTERN

    Hole Size & Spacing % Open Air

    1/16 x 0.1626 11.6

    1/16 x 0.3788 2.1

    1/16 x 0.1894 8.54

    3/32 x 0.2706 9.4

    1/8 x 0.325 11.6

    1/16 x 0.3247 2.9

    3/32 x 0.3247 6.5

    1/4 x 0.650 11.6

    Perforated wall cladding fabrication provides a 10% to 40% open area creating the effect of a translucent screen to provide passive solar shading, control light and sound pollution, air movement or simply to obscure roof top mechanical equipment.

    Panels can be orientated horizontally, vertically or diagonally based upon the design.

  • 11BUILDING FOR TOMORROW

    MARQUIS 450*

    17 23/32”(450 mm)

    1 25/32”(45 mm)

    Painted Side

    *MARQUIS 450 is part ofan Engineered Roof System

    Painted Side

    1 1/2”(38 mm)

    20” (508 mm)

    Available in Prestige-SR 20 (without rib)

    PRESTIGE-R 20”

    PRESTIGE-R 16”

    1 1/2”(38 mm)

    Painted Side

    16” (406 mm)

    Available in Prestige-SR 16 (without rib)

    TRADITION 100-4

    Application Note: TRADITION 100-4 can be curved convex. Please verifiy with your Vicwest representative.

    15 3/4” (400 mm)

    Painted Side

    7/8”(22.25 mm)

    TRADITION 150-4

    15 3/4”(400 mm)

    1 1/2”(38 mm)

    Painted Side

    Application Note: Roof seamers are required for installation of this

    ROOF SYSTEM PROFILES

    TSR*

    Application Note: Roof seamers are required for installation of this

    24”(609 mm)

    2 3/4”(69 mm)

    Painted Side

    *TSR is part of an Engineered Roof System Roof: TRADITION 100 Ontario Travel Information Centre, Sarnia, ONDavid Gilchrist Architects

    NOTE: Minimum roof slope can vary between profiles. Please consult your Vicwest Representative

    PRESTIGE 12”

    1 1/2”(38 mm)

    Painted Side

    12” (305 mm)

    Manufactured in the West

    Exposed side pre-painted(Dim.) = mm

  • 12 www.vicwest.com

    RD - Roof Deck HB - Hi-Bond® Floor Deck CL - Cladding Lap

    RD306/RD306-CL/HB306/HB306-CL Deck Lap Shown

    RD306-CL used as a prefinished profile. Available only in 18" coverage (not shown). Contact your Vicwest representative for additional information.

    3”(76 mm)

    24” (609 mm)

    24” (609 mm)

    3”(76 mm)

    6”(152 mm)

    Cladding Lap Shown

    Exposed Surface

    Exposed Surface

    ROOF & FLOOR DECK PROFILES

    Toronto Pearson International Airport Terminal 1

    Airports Architects Canada

    RD938/RD938-CL/HB938/HB938-CL

    1 1/2”(38 mm)

    35 7/16”(900 mm)

    5 29/32”(150 mm)

    Exposed Surface

    Deck Lap ShownEdmonton

    RDS938/RDS938-CL/HBS938/HBS938-CL

    Available inverted (INV)

    1 1/2”(38 mm)

    36”(914 mm)

    Exposed Surface

    CL – Cladding Lap ShownStratford

    Exposed side pre-painted(Dim.) = mm

  • 13

    Closure

    207

    507

    707

    5/8”(16)

    7/8”(22)1-1/8”(29)

    1107

    1407

    1807

    1-1/2”(38)

    2-3/4”(70)4”

    (102)

    A

    Conversion Moulding

    215

    515

    715

    3/4”(19)

    5/8”(16)

    4-1/4”(108)

    2”(50)

    4-3/4”(121)

    2-1/4”(57)

    2-3/4”(70)

    2-1/4”(57)

    1”(25)

    1”(25)

    1”(25)

    1-1/2”(38)

    C D

    2”(51)

    1”(25)

    3”(76)

    3”(76)

    C D

    CD

    B

    A

    3003

    Closure

    * to be specified

    1-1/2”(38)

    Minimum

    1-1/

    2” (

    38)

    Clip

    3024

    5/8”(16)

    2-3/8”

    (60)

    200 Series - CL508/CHANNELWALL, CL7015/815 and 1/2” CORRUGATED500 Series - SUPERVIC, DIAMOND RIB700 Series - ELITE, 7/8” CORRUGATED1100 Series - CL7040/840, CL6025/725, CL5022/622, CL3035/435 and AD150/200/275/300 1800 Series - CL3100/400 3000 Series - Generic

    All flashings/trims are available 10’-0” long.Custom flashings to specific requirements are available upon request.Please consult your Vicwest representative.

    TRIMS & ACCESSORIESExposed side pre-painted(Dim.) = mm

    BUILDING FOR TOMORROW

    REFERENCE

  • 14 www.vicwest.com

    TRIMS & ACCESSORIES (continued)See REFERENCE on Page 13

    Exposed side pre-painted(Dim.) = mm

    Conversion Moulding

    220

    520

    720

    112011/16”(17)5/8”(16)

    1”(25)

    1-1/2”(38)

    1”(25)

    1”(25)

    2-3/16”(56)

    3”(76)

    2-5/8”(67)

    C

    2”(51)

    1”(25)

    2-1/2”(64)

    C

    A

    B

    C

    Drip

    216

    516

    716

    1116

    3/4”(19)

    3/4” (19)

    1-1/8”(29)

    1-1/2”(38)

    3/4” (19)

    3/4” (19)

    3” (76)

    4-1/2” (108)

    2”(51)

    3/4” (19)

    3-1/2” (89)

    5-1/4” (133)

    C

    C

    B

    * to be specified

    A

    Drip

    * 3/4” (19), 1” (25), 1-1/2” (38),2” (51), 3” (76), 3-1/2” (89), 4” (102), 5” (127), 6” (152), 9” (229) to be specified

    217

    517

    717

    1117

    3/4”(19)

    3/4” (19)

    1-1/8”(29)

    1-1/2”(38)

    3/4” (19)

    3/4” (19)

    +/- 3” (76)

    +/- 3-1/4” (83)

    +/- 3” (76)

    +/- 3” (76)2”(51)3/4” (19)

    C

    *

    C

    B

    A

    Drip

    * 3/4” (19), 1” (25), 1-1/2” (38),2” (51), 3” (76), 3-1/2” (89), 4” (102), 5” (127), 6” (152), 9” (229) to be specified

    218

    518

    718

    1118

    3/4”(19)

    3/4” (19)

    1-1/8”(29)

    1-1/2”(38)

    3/4” (19)

    3/4” (19)

    2”(51)

    3/4” (19)

    C

    *

    CB

    A

    +/- 3” (76)

    +/- 4” (102)

    +/- 4-1/2” (114)

    +/- 3-1/2” (89)

  • 15

    Drip

    222

    522

    1122

    722

    3/4”(19)

    3/4” (19)

    1-1/8”(29)

    1-1/2”(38)

    3/4” (19)

    3/4” (19)

    4-1/2” (108)

    3” (76)

    2”(51)

    3/4” (19)

    5” (127)

    3-3/4” (95)

    C

    CB

    A

    Downspout

    DS-4

    DS-6

    4”(102)

    6”(152)

    5/8”(16 mm)

    4”(102)

    6”(152)

    5/8”(16 mm)

    B

    A

    DSC-4

    DSC-6

    Downspout Backing

    A

    Drip

    219

    519

    719

    1119

    3/4”(19)

    3/4” (19)

    1-1/8”(29)

    1-1/2”(38)

    3/4” (19)

    3/4” (19)

    2”(51)

    3-1/4” (83)

    2”(51)

    3/4” (19)

    2-3/4” (70)

    2-3/4” (70)

    C

    C

    B

    A

    All flashings/trims are available 10’-0” long.Custom flashings to specific requirements are available upon request.Please consult your Vicwest representative.

    TRIMS & ACCESSORIES (continued)Exposed side pre-painted(Dim.) = mm

    See REFERENCE on Page 13

    BUILDING FOR TOMORROW

  • 16 www.vicwest.com

    Eavestrough

    79535

    3/4” (1

    9)

    4” (

    103)

    1” (

    25)

    4” (103)

    1” (25)

    6” (

    153)

    2” (51)

    (13)1

    /2”

    Eavestrough Clip

    * Specify Angle ‘X’(Req’d. 2’-0” C/Cs)

    2” (51)

    3-3/

    4” (9

    5)

    1-1/

    2” (

    38)

    1” (

    25)

    Inside Corner

    IN-1

    IN-2

    2-1/2”(64)

    4”(102)

    A

    Inside Corner

    201

    501

    701

    110111/16”(17)1”

    (25)3/4”(19)

    2-1/8”(54)

    7/8”(22)

    2-1/2”(64)

    7/8”(22)

    3”(76)

    3/4”(19)

    1-15/16”(49)

    15/16”(24)

    1”(25)

    1”(25)

    1 1/8”(29)

    1-5/8”(41)

    1”(25)

    C

    C D C D

    D

    1/8”(3)

    Inside Corner

    208

    508

    1108

    1408

    1808

    5/8”(16)

    1”(25)

    708 1-1/4”(32)

    1-3/4”(44)

    3”(76)

    4-3/16”(106)

    A

    TRIMS & ACCESSORIES (continued)

    Walls: 7/8" CORRUGATEDWaterloo Fire Station, Waterloo, ON

    Architects: alaimo architecture inc.

    Exposed side pre-painted(Dim.) = mm

  • 17

    Jamb

    213

    513

    713

    11133/4”(19)

    15/16”(24)

    1-1/8”(29)

    5/8”(16)

    2-1/2”(64)

    2-1/4”(57)

    4-7/8”(124)

    3-7/8”(98)

    1”(25)

    1”(25)

    1-5/8”(41)

    1”(25)

    B

    C

    A

    Jamb

    * 3/4 (19), 1” (25), 1-1/2” (38), 2” (51), 3” (76), 4” (102), 5” (127), 6” (152), 9” (229) to be specified*

    211

    511

    711

    111111/16”(17)

    1411

    1811

    5/8”(16) *

    15/16”(24)

    1”(25)

    1-1/8”(29)

    1”(25)

    *

    *

    1-5/8”(41)

    2-7/8”(73)

    4-1/16”(103)

    1”(25)

    1-1/2”(38)

    1-1/2”(38)

    *

    *

    *

    C

    A

    B

    “J Trim”

    210

    510

    1110

    710

    11/16” (17)

    5/8” (16)

    15/16” (24)

    1-1/8” (29)

    1” (25)

    15/16” (24)

    1-3/16” (30)

    3-3/8” (86)

    2-3/4” (69)

    C

    1-5/8” (41)

    1” (25)

    2-7/8” (73)

    C

    B

    C

    A

    TRIMS & ACCESSORIES (continued)

    Vermin-Proof Moulding

    240

    540 1140

    7403/4”(19)

    2”(51)

    1-1/8”(29)

    2-1/2” (64)

    2-1/2” (64)

    2”(51)

    C

    1-1/2”(38)

    3” (76)

    2”(51)

    3-1/2” (89)

    4” (102)

    3” (76)

    C

    C

    B

    A

    Exposed side pre-painted(Dim.) = mm

    BUILDING FOR TOMORROW

  • 18 www.vicwest.com

    Outside Corner

    704

    204

    504

    11045/8”(16)3/4”(19)

    2-3/4”(70)

    1-7/8”(48)

    3-1/2”(89)

    2-3/8”(60)

    2-3/4”(70)

    2-13/16”(71)

    15/16”(24)

    1”(25)

    1”(25)

    1-1/8”(29)

    C D

    1-5/8”(41)

    1”(25)

    3-1/2”(89)

    2-3/4”(70)

    C D

    C

    D

    B

    A

    Outside Corner

    5/8”(16)

    2-3/4”(70)

    1”(25)

    2-3/4”(70)

    206

    506

    706 1-1/4”(32)3-1/2”(89)

    3-1/2”(89)

    5”(127)

    5-1/2”(140)

    1-3/4”(44)

    3”(76)

    4-3/16”(106)

    B

    A

    Outside Corner

    EX-2

    EX-1 2-1/2”(64)4”

    (102)

    A

    All flashings/trims are available 10’-0” long.Custom flashings to specific requirements are available upon request.Please consult your Vicwest representative.

    Walls: AD300 Vertical, and TRADITION 100

    Northlands Exposition Centre

    Edmonton, AB Architects: DIALOG

    TRIMS & ACCESSORIES (continued)

    Outside Corner

    200

    500

    700

    5/8”(16)

    1-1/4”(32)

    3/4”(19)

    1-3/4”(44)

    1”(25)

    3-1/4”(83)

    1”(25)

    2-3/16”(56)

    15/16”(24)

    1-3/4”(44)

    2-1/4”(57)

    1-1/8”(29)

    C D

    C

    D

    B

    A

    Exposed side pre-painted(Dim.) = mm

  • 19

    FA-6

    FA-8

    FA-12

    5-3/8”(136)

    8”(203)

    11”(279)

    Ridge Cap

    A

    To specify

    Ridge Roll

    FR-6

    FR-8

    2-7/16”(62)

    3-13/16”(97)

    A

    To specify

    Roof Flashing

    *4-5/8” (117), 7-5/8” (194)10-5/8” (270), 13-5/8” (346)

    A

    To specify

    3/4” (19)

    3” (

    76)

    Roof Flashing

    *5-1/2” (140), 8” (203)

    A

    To specify

    4-1/

    2” (

    114)

    3/4”(19)

    Roof Flashing

    * 9-1/8” (232), 12-1/8” (308)

    A

    4-1/

    2” (

    114)

    3/4”(19)

    Roof Flashing

    * 6” (152), 9” (229),12” (305), 15” (381)

    5-1/2” (140

    )

    A

    To specify

    TRIMS & ACCESSORIES (continued)Exposed side pre-painted(Dim.) = mm

    BUILDING FOR TOMORROW

  • 20 www.vicwest.com

    68.88 sq. ins.4

    Vented Ridge (Model 1200)

    Vicwest Vented Ridge allows damp warm air to circulate out of attics that would otherwise assist in the deterioration of insulation and roof structures.

    Rows of Perforations

    Total Opening Area per 10’-0” Section

    7”

    2”

    4” 2-3/4”

    12-3/4”

    3002

    Sill

    A & B

    * to specify

    3/4” (19)

    95˚

    2-1/

    2”

    (64)

    BA

    Starter Strip

    223

    523

    723

    11233/4”(19)1-1/8”

    (29)

    1-1/2”(38)

    2”(51)

    2-1/2” (64)

    3” (76)

    3-3/4” (95)

    5” (127)

    A

    B

    TRIMS & ACCESSORIES (continued)

    Partition Moulding

    221

    521 1121

    72111/16”(17)2”(51)

    3/4”(19)

    2-1/16”(52)

    1”(25)

    2-13/16”(71)

    15/16”(24)

    2-1/2”(64)

    C D

    1-1/8”(29)

    3-1/4”(83)

    1”(25)

    2-1/4”(57)

    1”(25)

    3-1/4”(83)

    1-5/8”(41)

    3-1/4”(83)

    C D

    A

    D

    B

    C

    All flashings/trims are available 10’-0” long. Custom flashings to specific requirements are available upon request.

    Colchester East Hants Health Centre

    Truro, NSArchitects:

    Architecture 49

    Exposed side pre-painted(Dim.) = mm

  • 21

    Walls: 7/8” CORRUGATED Offset horizontally & vertically

    Servus Credit Union, Edmonton, AB

    “J Trim” AD300 Vertical

    ADT-C

    1-1/2”

    1-3/8”(29)

    (38)

    Outside Corner AD300 Vertical

    1-1/2” (38)

    2-1/

    2”

    (64)

    Inside Corner AD300 Vertical

    2-1/2”

    1-1/2”(38)

    (64)

    Jamb AD300 Vertical

    1-3/8”

    1-1/8”(29)

    (35)

    AD300 TRIMS & ACCESSORIESExposed side pre-painted(Dim.) = mm

    BUILDING FOR TOMORROW

  • 22 www.vicwest.com

    Standard in 10’-0”

    (3048 mm) Lengths

    Notched for L-800 Profile in

    31” Lengths

    No. No. “X” dimension “Y” dimension

    Z-75 — 3/4”(19 mm)1-29/64” (37 mm)

    Z-100 — 1” (25 mm)1-33/64” (38 mm)

    Z-150 ZE-150 1-1/2” (38 mm)1-13/32” (36 mm)

    Z-200 ZE-200 2” (51 mm)1-13/32” (36 mm)

    Z-250 ZE-250 2-1/2” (64 mm)1-17/32” (39 mm)

    Z-300 ZE-300 3” (76 mm)1-7/8”

    (48 mm)

    Z-350 ZE-350 3-1/2” (89 mm)1-3/8”

    (35 mm)

    Z-400 ZE-400 4” (102 mm)2-3/64” (52 mm)

    Z-450 ZE-450 4-1/2” (114 mm)1-35/64” (39 mm)

    Z-500 ZE-500 5” (127 mm)1-1/2”

    (38 mm)

    Z-550 ZE-5505-1/2"

    (140 mm)1-1/2”

    (38 mm)

    Z-600 ZE-600 6” (152 mm)1-13/16” (46 mm)

    A 1”(25 mm)

    Standard in 10’-0”

    (3048 mm) Lengths

    No. “X” dimension “Y” dimension “YY” dimension

    U-75 3/4”(19 mm)3-5/8”

    (92 mm)1-1/2”

    (38 mm)

    U-100 1” (25 mm)3-3/8”

    (86 mm)1-1/2”

    (38 mm)

    U-150 1-1/2” (38 mm)2-7/8”

    (73 mm)1-1/2”

    (38 mm)

    U-200 2” (51 mm)2-5/8”

    (67 mm)1-1/4”

    (32 mm)

    U-250 2-1/2” (64 mm)3-3/64” (77 mm)

    1-1/2” (38 mm)

    U-300 3” (76 mm)2-35/64” (65 mm)

    1-1/2” (38 mm)

    U-350 3-1/2” (89 mm)2-19/64” (58 mm)

    1-1/4” (32 mm)

    U-400 4” (102 mm)3-5/16” (84 mm)

    1-1/2” (38 mm)

    U-450 4-1/2” (114 mm)2-13/16” (71 mm)

    1-1/2” (38 mm)

    U-500 5” (127 mm)2-9/16” (65 mm)

    1-1/4” (32 mm)

    U-550 5-1/2” (140 mm)3”

    (76 mm)1-1/2”

    (38 mm)

    U-600 6” (152 mm)2-3/4”

    (70 mm)1-1/4”

    (32 mm)

    B

    No. “X” dimension “Y” dimension “YY” dimension

    H-62 5/8”(16 mm)13/16”

    (21 mm)1-1/2”

    (38 mm)

    H-75 3/4” (19 mm)1”

    (25 mm)1-1/2”

    (38 mm)

    H-100 1” (25 mm)3/4”

    (19 mm)1-1/2”

    (38 mm)

    H-150 1-1/2” (38 mm)1-1/16” (27 mm)

    1-1/2” (38 mm)

    H-200 2” (51 mm)3/4”

    (19 mm)2”

    (51 mm)

    H-250 2-1/2” (64 mm)21/32”

    (17 mm)2-1/2”

    (64 mm)

    H-300 3” (76 mm)1-3/8”

    (35 mm)3”

    (76 mm)

    C

    AB

    C

    * Notched sub-girts are also available. Vicwest reserves the right to change dimensions, (except the “x” dimension), without notice. For other lengths and/or dimensions, please consult Vicwest.

    SUB-GIRTS

  • 23

    PHOTO GALLERYRoof: TRADITION

    Moncton Casino, Moncton, N.B. Architects: NORR

    PROJECT GALLERY

    Roof and Exterior Walls: TRADITION 150 Interior Walls and Ceiling: AD300-R

    Canada 150 Pavillion

    London, ONMatter Architectural

    Studio Inc.

    Walls: 7/8" CORRUGATED Dalhousie University, Life Sciences BuildingHalifax, NS

    Architects: WHW Architects Inc.

    BUILDING FOR TOMORROW

    Profiles: AD150, AD200-SR, AD275-SR

    Oakville Arena Redevelopment Oakville, ON

    Architects: diamond schmitt

  • A metal wall cladding system adds style, beauty and character to your building’s design, regardless of size or shape. Vicwest’s systems are designed to exceed your aesthetic and functional needs.

    The Vicwest Commitment

    For more than 85 years, we’ve understood

    that people choose Vicwest not only because

    we build superior products, but because we

    stand behind them. Every Vicwest product

    we sell is backed by the best warranty in the

    business so you can rest assured that the roof

    you choose today, will protect your home for

    years to come. At Vicwest, we’re committed

    to continually improving upon and developing

    new building products to protect the places

    where we live, work and play. At Vicwest,

    we’re building for tomorrow.

    Note: For more information about building with steel,

    please refer to the CSSBI publication on the structural

    integrity of steel building panels.

    In accordance with ongoing efforts to improve our

    products and their performance, Vicwest Building

    Products reserve the right to change without notice the

    specifications contained herein.

    The contents herein are for general information and

    illustrative purposes only and are not intended to serve

    as any type of advice. Every effort is made to ensure the

    accuracy of the information included in this brochure

    and it is believed that the information contained herein

    is accurate and reliable as of the date of publication.

    Vicwest Building Products does not warrant or represent

    the accuracy or reliability of any information included in

    this brochure. Any reliance on any information without

    consultation with Vicwest Building Products or a duly

    authorized representative shall be at the user’s own risk.

    Fassade System using 7/8” CORRUGATED and AD300-R (horizontal and vertical)

    London Gymnastics AssociationArchitects: a+LINK Architecture Inc.

    ©2019 Vicwest Building Products – All rights reservedVW00149EN09/19

    vicwest.com BUILDING FOR TOMORROW

    Edmonton, AlbertaSaskatoon, Saskatchewan

    *Burlington, OntarioStratford, Ontario

    Victoriaville, QuebecMemramcook, New Brunswick

    Kensington, PEI

    VICWEST LOCATIONS