Page 1 of 12 939599284 Rev D 1/2" Dia. 5/16" Dia. If you have a problem, question, or request, call your local dealer, or Steelcase Line 1 at 888.STEELCASE (888.783.3522) for immediate action by people who want to help you. (Outside the U.S.A., Canada, Mexico, Puerto Rico, and the U.S. Virgin Islands, call: 1.616.247.2500) Or visit our website: www.steelcase.com © 2011 Steelcase Inc. Grand Rapids, MI 49501 U.S.A. Printed in U.S.A. #2 PHILLIPS BIT Topic Page Rail Mount Kit 2 Privacy Wall Mount Kit 5 Post and Beam Mount Kit 7 media:scape Mount Kit 8 Single Gang Junction Box Mount Kit VIA Glass Mount Standard Glass Mount 9 10 12 Table of Contents RoomWizard ® II Mounting Kits c:scape Rail Mount Kit 4

Upload: others

Post on 26-Jul-2020

2 views

Category:

Documents


0 download

TRANSCRIPT

Page 1: RoomWizard II Mounting Kits - Amazon S3...Mount Kit Compatibility: •Post and Beam 1. Align T-nuts with holes on bottom of universal bracket mount and loosely tighten. 2. Place universal

Page 1 of 12939599284 Rev D

1/2" Dia.5/16" Dia.If you have a problem, question, or request, call

your local dealer, or Steelcase Line 1 at888.STEELCASE (888.783.3522)for immediate action by people who want to help you.

(Outside the U.S.A., Canada, Mexico, Puerto Rico, and the U.S. Virgin Islands, call: 1.616.247.2500)Or visit our website: www.steelcase.com© 2011 Steelcase Inc.Grand Rapids, MI 49501 U.S.A.

Printed in U.S.A.

#2 PHILLIPS BIT

Topic Page

Rail Mount Kit 2

Privacy Wall Mount Kit 5

Post and Beam Mount Kit 7

media:scape Mount Kit 8

Single Gang Junction Box Mount Kit

VIA Glass Mount

Standard Glass Mount

9

10

12

Table of Contents

RoomWizard® II Mounting Kits

c:scape Rail Mount Kit 4

Page 2: RoomWizard II Mounting Kits - Amazon S3...Mount Kit Compatibility: •Post and Beam 1. Align T-nuts with holes on bottom of universal bracket mount and loosely tighten. 2. Place universal

Page 2 of 12939599284 Rev D

3b

3a

2

SCREW

3c

1/2" DRILL BIT

EXTRUSION

SLOT

T-NUT

ADAPTOR PLATE

Rail Mount Kit

Compatibility:•FrameOne•c:scape Beam•c:scape back to back desk (bench)•c:scape desk

Frame One

1. Determine location ofRoomWizard II.

2. Insert two (2) screwsthrough holes in adaptorplate and into T-nuts.Loosely tighten.

3. Place adaptor plateonto extrusion making sureT-nuts fit into slots (3a)and mark hole with pencil(3b). Remove adaptorplate and drill a 1/2" holeinto extrusion (FrameOneor c:scape beam) forpower over ethernet cable(3c).

4. Place adaptor plateback onto extrusion,making sure T-nuts fit intoslots and tighten onto extrusion.

T-NUT(PLACEMENT STATE)

4

T-NUT(INSTALLED STATE)

Page 3: RoomWizard II Mounting Kits - Amazon S3...Mount Kit Compatibility: •Post and Beam 1. Align T-nuts with holes on bottom of universal bracket mount and loosely tighten. 2. Place universal

Page 3 of 12939599284 Rev D

7b#6-32

MACHINE SCREW

7a

UNIVERSALBRACKETCOVERPOWER OVER

ETHERNET CABLE

6

UNIVERSAL BRACKET MOUNT

#10-24MACHINE SCREW

WASHER

5. Route power over ethernet cable through extrusion andadaptor plate.

6. Secure universal bracket mount to the adaptor plate usingtwo (2) #10-24 machine screws and two (2) washers.

7. Align universal bracket cover and puck with the universalbracket mount. Route power over ethernet cable throughuniversal bracket cover and puck (7a).Attach universal bracket cover and puck to universal bracketmount using the four (4) provided #6-32 machine screws witha #2 phillips screwdriver (7b).

8. Refer to RoomWizard II installation quickstart guide forremaining assembly.

5

POWER OVERETHERNET CABLE

MOUNTINGPUCK

Page 4: RoomWizard II Mounting Kits - Amazon S3...Mount Kit Compatibility: •Post and Beam 1. Align T-nuts with holes on bottom of universal bracket mount and loosely tighten. 2. Place universal

Page 4 of 12939599284 Rev D

c:scapeRAIL

T-NUT

UNIVERSAL BRACKET MOUNT

2

3

SLOT

4

5

c:scape RailMount Kit

1. Determine location ofRoomWizard II.

2. Align T-nuts withholes on bottom ofuniversal bracket mountand loosely tighten.

3. Place universalmount bracket onto railmaking sure T-nuts areplaced into slot on rail.

4. Route power overethernet cable throughsquare hole in bottom ofuniversal bracket mount.

5. Tighten the two (2)provided T-nuts using aphillips screwdriver.

6. Perform steps 6a and6b on page 3.

7. Refer to RoomWizard IIinstallation quickstartguide for remainingassembly.

Page 5: RoomWizard II Mounting Kits - Amazon S3...Mount Kit Compatibility: •Post and Beam 1. Align T-nuts with holes on bottom of universal bracket mount and loosely tighten. 2. Place universal

Page 5 of 12939599284 Rev D

1a

1c2

1b

1/2" DRILL BIT

5/16" DRILL BIT

5/16" DRILL BIT

UNIVERSALBRACKET MOUNT

EXTRUSION

Privacy WallMount Kit

Compatibility:•Mounting applications where there is not enough room for toggle anchor.

1. Position universal mountbracket onto extrusion (1a).

Mark two 5/16" holes onextrusion for bracket hardwareand one (1) 1/2" hole for powerover ethernet cable (1b).

Remove universal bracketmount from extrusion anddrill two (2) 5/16" holes forbracket hardware and one (1)1/2" hole for the power overethernet cable (1c).

2. Route cable through 1/2"drilled hole in extrusion.

Page 6: RoomWizard II Mounting Kits - Amazon S3...Mount Kit Compatibility: •Post and Beam 1. Align T-nuts with holes on bottom of universal bracket mount and loosely tighten. 2. Place universal

Page 6 of 12939599284 Rev D

3 4

UNIVERSALBRACKET MOUNT

POWER OVERETHERNET CABLE

MOUNTINGBRACKET

#10-24 SCREW

#6-32 SCREW

WASHER

6a 6b

UNIVERSALBRACKETCOVER

POWER OVER ETHERNET CABLE

3. Align universal bracket mount withholes in extrusion and holes in themounting plate which is positioned onother side of extrusion.

Route power over ethernet cablethrough "U" shape in the mountingplate, through 1/2" drilled hole inextrusion and then through squarehole in bottom of universal bracketmount.

4. Attach universal bracket mount toextrusion by inserting two (2) #10-24screws with washers through holes inuniversal bracket mount, holes inextrusion and holes in mountingbracket.

5. Level RoomWizard II and adjustscrews if necessary.

6. Align universal bracket and puckwith the universal bracket mount.Route power over ethernet cablethrough universal bracket cover andpuck (6a).

Attach universal bracket cover andpuck to universal bracket mount usingthe four (4) provided #6-32 machinescrews with a #2 Phillips headscrewdriver (6b).

7. Refer to RoomWizard II installationquickstart guide for remainingassembly. MOUNTING

PUCK

Page 7: RoomWizard II Mounting Kits - Amazon S3...Mount Kit Compatibility: •Post and Beam 1. Align T-nuts with holes on bottom of universal bracket mount and loosely tighten. 2. Place universal

Page 7 of 12939599284 Rev D

RAIL

T-NUT

UNIVERSAL BRACKET MOUNT

1

2

3

4

SLOT

WASHER

1/4-20MACHINE

SCREW

Post and BeamMount Kit

Compatibility:•Post and Beam

1. Align T-nuts with holeson bottom of universalbracket mount and looselytighten.

2. Place universal mountbracket along with T-nutsonto rail making sureT-nuts are placed into sloton rail.

3. Route power overethernet cable throughsquare hole in bottom ofuniversal bracket mount.

4. Tighten the two (2)provided T-nuts using aphillips screwdriver.

5. Perform steps 5,6a and 6b on page 6.

6. Refer to RoomWizard IIinstallation quickstart guidefor remaining assembly.

NOTE: Do not mount RoomWizard II's so theyprotrude into an aisleway.

ADA requires objects projecting from walls withtheir leading edges between 27" and 90" (685 mmand 2030 mm) above the finished floor shallprotrude no more than 4" (100 mm) into walks,halls, corridors, passageways, or aisles.

Page 8: RoomWizard II Mounting Kits - Amazon S3...Mount Kit Compatibility: •Post and Beam 1. Align T-nuts with holes on bottom of universal bracket mount and loosely tighten. 2. Place universal

Page 8 of 12939599284 Rev D

1b1a

3

5/16" DRILL BIT FORFOUR (4) FASTENERS

1/2" DRILL BIT FORETHERNET CABLE

4

5

POWER OVER ETHERNET CABLE

MIN.52"

#6-32 SCREWNUT

media:scapeMount Kit

Compatibility:•media:scape or other structural members.

1. Position puck on media:scapea minimum of 52" from floor andmark four (4) locations to drill forfasteners (1a) and one (1) locationto drill for cable.

2. Confirm there are no items thatcould pose an interference on therearside of the media:scape shroud.

3. Drill 1/2" dia. hole for powerover ethernet cable and 1/4" dia.holes for fasteners.

4. Route power over ethernetcable through drilled 1/2" dia. holein media:scape shroud.

5. Screw the puck onto the shroudusing the provided four (4) screwsand four (4) washers and four (4)nuts.

6. Refer to RoomWizard IIinstallation quickstart guide forremaining assembly.

MOUNTINGPUCK

WASHER

Page 9: RoomWizard II Mounting Kits - Amazon S3...Mount Kit Compatibility: •Post and Beam 1. Align T-nuts with holes on bottom of universal bracket mount and loosely tighten. 2. Place universal

Page 9 of 12939599284 Rev D

HorizontalJunction Box

VerticalJunction Box

MOUNTINGPLATE

SCREW

1

2

1

33

2

SCREW

#6-32 SCREW

Single GangJunction BoxMount Kit

Compatibility:•Single gang junction box.

1. Route power overethernet cable throughmounting plate.

2. Attach mounting platedirectly to junction box. Ifbox is vertical, mount so thepuck mounting holes aretoward the top of the mount.

If the box is horizontal, mountso the puck mounting holesare nearest the roomopening.

3. Attach RoomWizard II topuck using two (2) providedset screws with a #2 phillipsscrewdriver.

4. Level RoomWizard II.Adjust screws if necessary

5. Refer to RoomWizard IIinstallation quickstart guidefor remaining assembly.

MOUNTINGPUCK

MOUNTINGPLATE

MOUNTINGPUCK

#6-32 SCREW

Page 10: RoomWizard II Mounting Kits - Amazon S3...Mount Kit Compatibility: •Post and Beam 1. Align T-nuts with holes on bottom of universal bracket mount and loosely tighten. 2. Place universal

Page 10 of 12939599284 Rev D

®

12

3

1. Unlock Lock rods for interior glassframe (C) and remove.

2. Clean mounting area of exterior glassframe (A) with alcohol pad on both sides(54-1/4” up from floor, 8” in from side).

3. Maintain cable length at 8” acrossface of glass frame.

INSTALLATION OF VIA

INTERIOR SIDE GLASS

FRAME C

8”

51-1/4”

FRAME ASIDE GLASS

Page 11: RoomWizard II Mounting Kits - Amazon S3...Mount Kit Compatibility: •Post and Beam 1. Align T-nuts with holes on bottom of universal bracket mount and loosely tighten. 2. Place universal

Page 11 of 12939599284 Rev D

®

4

3. Route cable through VIA mount cover and mount. Secure cable to cable retainer clip.

4. Engage cover spur into mount and pivot to align mounting holes. Route cable through opening in mount.

NOTE: Adhesive pad must adhere directly to glass.

5. If desired mounting location has vinyl film applied to glass,carefully cut a 76 mm diameter circle through the vinyl with an X’acto type blade. Remove the film from cutout area. Clean the exposed glass surface with an alcohol pad.

6. Remove film backing from adhesive pad. Locate alignment tabs against edge of glass frame and press VIA mount onto glass. VIA Mount will be centered at 51-1/4” H.

7. Position tab of wall bracket at top and fasten bracket tomount with (4) fasteners.

8. Remove film backing and affix back cover plate to opposite of glass. Refer to Room Wizard II Installation Quick Start Guide for remaining assembly.

9. Reinstall interior glass frame and lock in place using lock rods.

INSTALLATION OF VIA GLASS MOUNT CABLE RETAINERCLIP

COVER SPUR3

5

7

BACK COVERPLATE

COVER SPUR

Extra cable can be managed by filling openings.

MOUNT BRACKETTAB

WALL BRACKETTAB

6

TOP VIEW

Page 12: RoomWizard II Mounting Kits - Amazon S3...Mount Kit Compatibility: •Post and Beam 1. Align T-nuts with holes on bottom of universal bracket mount and loosely tighten. 2. Place universal

Page 12 of 12939599284 Rev D

®

125cm

to floor

Maximum 45cm

to extrusion

ALCOHOL PREP PAD

1 2 3

5 6

STANDARD GLASS MOUNT

#2

4