rotajet d80

14
Rotajet Systems Limited, Shaw Cross Business Park, Owl Lane, Dewsbury, West Yorkshire WF12 7RD Tel: 01924 468769 Fax: 01924 485376 E-MAIL [email protected] Page 1 of 20 Rotajet Systems Limited INSTRUCTION MANUAL M/C. Serial No. D80/548/02/09 Electrically Heated 2 Stage D80 Rotajet Description The Rotajet D80 two stage machine is a robustly constructed integral fabrication from 6mm mild steel plate comprising a washing area (1675mm) dia X 850mm high located above 2 heated liquor sumps. Due to the large size of the machine, certain items will have been removed for transportation purposes. The following procedure should be adopted for re-assembly. Assembly Instructions The machine should be sited on a level surface and positioned with sufficient space around it to facilitate clean out and servicing. Fit the door operating pneumatic cylinder to the mounting channel above the door at the front of the machine and the piston clevis to the door. (If Removed) Using a temporary, flexible feed, connect a compressed air supply to the bottom port of the pneumatic cylinder to lift the door. Securely prop open the door using stout baulks of timber or similar, clamp the prop in position and remove the temporary air supply from the cylinder. Connect the machine pneumatic pipework to the cylinder and establish the compressed air supply. Remove the items stored inside the machine for transportation. The basket is to remain in the machine. Using a level on the machine internal rails, check that the machine is level, if not, pack under the corners of the machine as required until level. If a particulate filter is provided, connect the filter into position using the bolts provided, ensuring that the gasket connections are sound. Locate the front roller section. The front roller track is to be bolted to the front of the machine, once the track is secured to the machine using a level on the roller track rails, check that the roller track is level, pack under the roller track feet accordingly. Once the roller track

Upload: chrisfergusonn

Post on 27-May-2017

266 views

Category:

Documents


1 download

TRANSCRIPT

Page 1: ROTAJET D80

Rotajet Systems Limited,

Shaw Cross Business Park,

Owl Lane, Dewsbury,

West Yorkshire WF12 7RD

Tel: 01924 468769

Fax: 01924 485376

E-MAIL –[email protected]

Page 1 of 20

Rotajet Systems Limited

INSTRUCTION MANUAL

M/C. Serial No. D80/548/02/09

Electrically Heated 2 Stage D80 Rotajet

Description

The Rotajet D80 two stage machine is a robustly constructed integral fabrication from 6mm

mild steel plate comprising a washing area (1675mm) dia X 850mm high located above 2

heated liquor sumps.

Due to the large size of the machine, certain items will have been removed for

transportation purposes. The following procedure should be adopted for re-assembly.

Assembly Instructions The machine should be sited on a level surface and positioned with sufficient space around it

to facilitate clean out and servicing.

Fit the door operating pneumatic cylinder to the mounting channel above the door at the front

of the machine and the piston clevis to the door. (If Removed)

Using a temporary, flexible feed, connect a compressed air supply to the bottom port of the

pneumatic cylinder to lift the door.

Securely prop open the door using stout baulks of timber or similar, clamp the prop in

position and remove the temporary air supply from the cylinder.

Connect the machine pneumatic pipework to the cylinder and establish the compressed air

supply.

Remove the items stored inside the machine for transportation. The basket is to remain in the

machine.

Using a level on the machine internal rails, check that the machine is level, if not, pack under

the corners of the machine as required until level.

If a particulate filter is provided, connect the filter into position using the bolts provided,

ensuring that the gasket connections are sound.

Locate the front roller section. The front roller track is to be bolted to the front of the

machine, once the track is secured to the machine using a level on the roller track rails, check

that the roller track is level, pack under the roller track feet accordingly. Once the roller track

Page 2: ROTAJET D80

2 Stage D80, Electrically Heated Instruction Manual

Serial No. D80/548/02/09

Page 2 of 20

Rotajet Systems

is level secure the track to the floor using fixing bolts. Connect the power

load drive chain to the basket, the bottom chain which is located at each side of the roller

track is to be passed through the two bottom box section guides located at the front of the

machine, along the lower guides in the machine and out of the bottom holes situated in the

rear of the machine. The chain is then to be passed around the none drive end sprockets, and

back through the upper holes located at the rear of the machine, attach the chain to the rear of

the basket. The basket will require moving to ensure the chain is kept in tension. The upper

sections of the drive chain is to be connected to the front of the basket using the clips

provided. Once both the back and the front are securely connected on both side of the basket

the chain tension is to be checked and adjusted using the chain adjustment bolts on the rear of

the basket.

Caution: When installing the chain, ensure the chain around the drive sprocket is in tension at

all times. This will reduce the possibility of the chain disengaging from the sprockets.

Connect the power load roller track wires, the wires are to be fed into the panel via the large

truncking located within the machine. All the wires are numbered accordingly, connect the

wires to the relevant terminals.

Remove the door props. (Note! Personnel must not work inside the cabinet after the door

prop is removed)

Complete the establishment of services to and from the machine. a) 380 - 415 volt 50 Hz. Three-phase electricity to the 125-amp isolator provided on the

remote control panel.

b) Clean, dry, compressed air @ 5.5 bar minimum to the service unit provided.

c) Clean water to the ½” BSP infill pipes provided.

d) Sump tank drain valve 1 ½” located at the rear of the machine.

e) Pressure filter drain valve 1” located at the rear of the machine.

f) Steam extraction 250mm ducting.

CAPACITIES Kw. RATING

Sump + Filter (Wash) 640 Lt.

Pump (Wash) 11.0 kW

Sump Heating (Wash) 36.0 kW

Sump (Rinse) 500 Lt.

Pump (Rinse) 7.5 kW

Sump Heating (Rinse) 24.0 kW

Extraction Fan 0.25 kW

Power Load System 0.25kW

Particle Filter 110 Lt

Page 3: ROTAJET D80

2 Stage D80, Electrically Heated Instruction Manual

Serial No. D80/548/02/09

Page 3 of 20

Rotajet Systems

OPERATION

1) After ensuring that all openings to the sumps are secure and closed, both sumps should

now be filled with water using the valves located at the rear of the machine on the water

inlet pipework. A dosatron unit is located within the wash water line, the dosarton unit

percentage is to be pre-set during the commissioning period (The percentage is determine

on the chemical used).The chemical is to be located on the ground local to the dosatron

unit, the plastic feed pipe is then to be placed into the chemical, ensuring the filter located

at the end of the plastic pipe is at the bottom of the chemical container.

2) Initial Start up after Machine is Re-Assembled with all services established to the

machine and the machine door closed.

a) Open panel door and ensure all MCB’s are pressed in to the ON position

b) Close panel door and turn the isolator to ‘ON’.

c) Remove the basket from the machine using the Basket Out button located on the

control panel. The basket will stop in its load position.

d) Reload the basket into the machine by pressing the Basket In button located on the

control panel.

e) The basket will stop at the correct position inside the machine.

f) Close the machine door by pressing the Door Down button, the button is to be pressed

in until the door is in its final closed position.

g) Press ‘CYCLE START’ button, allow to run for a few seconds then press the stop

button getting a colleague to observe the direction of rotation of the wash pump, this

should be clockwise when viewed from the rear of the motor. If the direction of

rotation is incorrect, isolate the machine and change over two of the incoming phases.

Note! Do Not alter any of the machine wiring. When the incoming phases are

correct, all the motors on the machine will rotate in the correct direction.

3) Turn the two sump heater switches on which will activate the heaters in both sumps,

illuminating the relevant heater indicator lights. The adjustable thermostat’s that are

located in the marked heater housings and have been set to 70°C they should not need

any further adjustment. When the set temperature is reached, the indicator lights will go

out, these lights will then illuminate and extinguish as directed by the thermostat control.

Working Cycle when Machine is at Temperature.

Open the wash cabinet door, by pressing the Door Open button located on the control

panel. The button is to be pressed at all time whilst the door is been opened, if the button

is realised the door will stop. The door will stay in the stopped position until either the

door open of door close button is pressed.

1. Once the door is fully open remove the basket from the machine, by pressing the

Basket Out button located on the control panel. An amber light located on the loading

track will flash when the basket is moving.

Caution: The Operator is to check to ensure the area local to the machine is clear of any

personal when the basket is loaded or unloaded from the machine.

2. Load component into the basket.

Page 4: ROTAJET D80

2 Stage D80, Electrically Heated Instruction Manual

Serial No. D80/548/02/09

Page 4 of 20

Rotajet Systems

3. Load the basket into the machine, by pressing the Basket In button located on the

control panel.

4. Close wash cabinet door, by using the Door Close button on the control panel. The

button is to be pressed at all times whilst the door is been closed Note: There is a time

delay from when the basket stops to when the door can be closed.

5. Press the cycle start button located on the control panel. The pressure gauge located at

the front of the machine is to be checked to ensure the machine is running at the

correct cleaning pressure for the relevant stag of the cycle. If the machine is not

running at the correct pressure press the stop button, remove the basket from the

machine. Investigate potential problem Ref trouble shooting section of the manual

Part 2 Page 2 and 3

6. The Wash, Wash Drain, Rinse and Rinse Drain Timers are all located with in the PLC

program, the timers will be set during the commissioning. (All timers are to be set in

accordance with Shell UK`s specification).

Lights located on the panel illustrate the machine cycle stage.

7. The blue ‘CYCLE OVER’ beacon located on top of the panel will indicate when the

cycle is over and interlocks are negated.

8. The basket is then to be removed from the machine, Ref Step 1 and 2.

9. The component is then to be removed from the basket.

Caution: Eye protection must be worn when removing parts from the machine basket.

10. If the stop button is pressed during a cycle, the machine will stop and all interlocks

will be negated. When a cycle is stopped in this manner, steps 1 to 8 will have to be

repeated (excluding loading and unloading of the component)

11. At the end of the cycle or if the stop button has been pressed the air inlet duct will

open and the extraction will start. The extraction fan will run until either it times out,

the cycle start button is pressed again. When the extraction fan is operational the air

inlet located at the rear of the machine will remain open.

The cycle process is: - Wash - Drain – Rinse – Drain & Cycle Over (Extraction)

Loading Machine

Components to be cleaned should be placed into the workbasket in such a way as to allow the

cleaning solution discharged from the jets in the rotating spray arms to impinge upon the

surfaces and allow good drainage, avoid masking one component with another as far as

possible and positioning components so that no water traps are formed, it is also important that

the workload does not overhang the basket where it could foul the path of the rotating spray

arms. The loaded basket is transferred into the machine using a power load system, Ref

loading details above

Page 5: ROTAJET D80

2 Stage D80, Electrically Heated Instruction Manual

Serial No. D80/548/02/09

Page 5 of 20

Rotajet Systems

Machine Maintenance and Equipment

Pump & Spray Nozzles

Centrifugal type pumps sited under the cleaning area at the front of the machine directs the

cleaning and rinsing solutions through 1 way valves and pipework to a common distribution

system designed to divide the flow between the top and bottom spray bars, arranged one to

clean from the sides, top and bottom of the components.

Steam Extraction Fan The steam extraction fan is wired into the control circuit such that it operates when the cycle

has reached the rinse drain stage or if the Stop button is pressed. When the extraction fan is

working the air inlet at the back of the machine is open. The extraction fan draws the air into

the wash cabinet and across the component assisting with the drying of the components, the air

and steam is evacuated by the fan into the machine ducting. The extraction fan will time out

after a given period reducing any additional heat loss through the ducting.

Rotajet advise that if the machine is not going to be used for a period of time the machine

basket should be loaded into the machine and the machine door closed.

Heaters

The heater switches located on the control panel door should be operated to energise the 9 x

6kW screw in type heating elements in the liquor sump. The 9 heaters are grouped in to the

three heater banks of three, two heater banks are located within the wash tank and one heater

bank is located with in the rinse tank

A common temperature control thermostat is located in each of the heater banks, the heater in

which the thermostat is located with is clearly marked with STAT, the temperature control is

variable from 40 to 120°C. factory setting is 70°C. A green indicator light is illuminated when

the heaters are operational and extinguishes when the set temperature is reached, this light will

come in and go out as the thermostat operates, the thermostat differential tolerance is + or - 3°

of the setting.

Low Water Level Switch

A low-level safety device is incorporated in the control circuit to prevent damage occurring to

the heating elements should the sump level be allowed to get to low. A red indicator light on

the panel door will illuminate at low water and the machine must not be used again until the

water level is replenished.

Note: When the machine isolator is switched on the low water light will illuminate, press the

stop button in then press the cycle start button, the water light should know extinguish. If the

light is still illuminated check the water level in the machine sumps.

Power Load System

The machine basket is transferred into the machine using a power load system, the system is

operated by buttons located on the control panel door. The basket will start moving

automatically when the basket in or out button is pressed, once the basket is moving it will

only stop when it reaches its correct position or the basket stop button is pressed. An amber

light located the front of the power load system will flash when the basket is moving. If the

basket stop button is pressed, the basket must then be removed from the machine using the

basket out button.

Page 6: ROTAJET D80

2 Stage D80, Electrically Heated Instruction Manual

Serial No. D80/548/02/09

Page 6 of 20

Rotajet Systems

Caution: If the basket stop button is pressed, under no circumstances must the Basket In button

be pressed.

Caution: Do not press the Basket In button whilst components are been loaded onto the basket.

Overload Fault

An overload fault light is located on the machine control panel, the light will illuminate if any

of the motor overload and trip. To reset the machine overload open the control panel door and

press the blue overload button on the contactor overloads.

Sump Drainage

The wash and rinse tank drain valves are located at the rear of the machine, the valves are to

be used when draining either the wash or rinse tanks. Its is essential that once the tanks are

emptying the valve is closed prior to re-filling of the tanks.

Sump Cleaning

Large hinged doors are provided in the sumps to facilitate raking out of solid contamination.

By lifting out the return flow filter basket, much of the sump is exposed to enable a thorough

flushing out to take place. The clean out door seals are of soft rubber and should be nipped

up only to form a seal. DO NOT OVERTIGHTEN. If a seal is swollen, distorted or

damaged in any way, it must be discarded and replaced with new.

Caution: The drain valves located at the rear of the machine must not be opened whilst the

machine is turned on

Caution: Eye protection must be worn when draining machine and cleaning the sumps

Page 7: ROTAJET D80

2 Stage D80, Electrically Heated Instruction Manual

Serial No. D80/548/02/09

Page 7 of 20

Rotajet Systems

ROUTINE MAINTENANCE INSTRUCTIONS

Before Start up each day

Clean out return flow filter basket.

Check liquor level and replenish if required.

(Note! When an extraction fan is employed, liquid losses are mainly water evaporation with

some loss of solution by drag out.)

Weekly

Ensure Jet orifices are clear. (Note! If entry into cabinet is required to do this, the machine

must be isolated and locked off before entry. If the temperature in the machine is above

43°C, 15mm thick plywood sheets should be placed on the shed plates to insulate the hot

surface before entry.)

Check Filter Socks

Monthly

Check to ensure bottom spray bar is rotating. (Note! Load the basket into the machine and

alien the bottom spray bar horizontal to the machine, close the machine door. Once the door

is closed press the cycle start button. Allow the machine to run for 1 minute and press the

stop button, leave the machine to rest for a further minute. Open the door and check to

ensure the bottom spray bar has moved form it original position. If the spray bar hasn’t move

investigate the bottom bushes as detailed on Page XX)

Check to ensure the top spray bar is oscillating. (Note! The oscillation of the spray bar is

indicated by the spray bar rotating indicator located on top of the spray bar guard. If the

spray bar is not working adjust the flow controls on the spray bar cylinder, the spaty bar

should be operating at 3-4 revs/min)

6 Monthly

Check clean out door seals for distortion

Check Pressure filter seal for distortion

Check door seal. (Note! Observe the machine whilst it is operating, if excessive water is

released down the side of the door or across the bottom of the door. Replace the door seals.)

Check pneumatic lubrication cylinder.

Year

Rotajet Systems recommended a yearly machine service.

Page 8: ROTAJET D80

2 Stage D80, Electrically Heated Instruction Manual

Serial No. D80/548/02/09

Page 8 of 20

Rotajet Systems

Cleaning Out

Operating conditions will determine the frequency of sump emptying, detergent renewal and

particulate filter element renewal. To clean out the machine: -

1. Open the wash cabinet door.

2. Remove the basket from the machine.

3. Press the stop button on the control panel.

4. Switch off the power at the isolator and lock off.

5. Remove the liquid from the sump and filter via the drain valve.

6. Remove and clean the filter basket.

7. Open the doors located at the rear of the sump and scrape clean the sump base. (No

build up of solids should be allowed to accumulate in the bottom of the sump)

8. Remove dished end cover from filter and proceed as below: -

To change the filter elements, first ensure the machine is isolated and padlocked off before

unfastening the six nuts securing the dished end cover, remove the cover. A clamping plate

with a single centre nut holds the filter elements in position, on removal of this plate the

socks can be withdrawn from their sleeves for emptying and cleaning, inspect the socks for

damage and provided the socks are not damaged in any way, they may be re-used, if any

damage is found, the sock should be discarded and renewed. To re-fit, reverse the procedure

ensuring the socks are right to the bottom of the sleeves (failure to do this will result in burst

elements on start up) and the felt collars securely located under the clamping plate. Inspect

the rubber seal to ensure it is sound, if there is any sign of damage or distortion, it should be

renewed. Replace the dished end cover and nip up the six clamping nuts evenly until a firm

seal is formed. Do Not Over-tighten. See exploded diagram on page 10

The clean out door seal and the particulate filter seals should be examined at regular intervals,

if there is any damage or distortion, it should be renewed. Do not over-tighten on these seals.

The cleanout door should just be nipped up to form a seal; the particulate filter seals should

be tightened up gradually until a firm seal is formed. All seals should be checked for leaks on

heating the machine and on pump start up.

Page 9: ROTAJET D80

2 Stage D80, Electrically Heated Instruction Manual

Serial No. D80/548/02/09

Page 9 of 20

Rotajet Systems

Page 10: ROTAJET D80

2 Stage D80, Electrically Heated Instruction Manual

Serial No. D80/548/02/09

Page 10 of 20

Rotajet Systems

Drawings Provided Number

Upper Spray Bar Assembly DA972

Machine Layout Drawing RJ633

Pneumatic Data DA954

Electrical Schematic Drawing – Mains DA956

Electrical Schematic Drawing – Control DA955

Electrical Schematic Drawing - PLC DA957

Recommended Spares

Quantity Description Part No.

10 15° Vee Pattern Spray Jets –St/St RJ155/A43

1 Large Clean Out Door Seal RJ165/A

1 Small Clean Out Door Seal RJ155A/32

2 Filter Seal RJFS15

6 Filter Sock Element RJFS400

Cleaning Of Spray Nozzles System

Cleaning Of Spray Nozzle and Pipework

Remove the end caps on the side and lower spray bar, run the

machine through a 30 second cycle, Re-install the end caps. Remove

the spray jets and clean using a small brush, re-install the spray jet

ensuring the jets are aligned correctly.

Once the system is cleaned it is advisable to clean the wash and rinse

filter baskets located at the rear of the machine and also the

particulate filter.

Page 11: ROTAJET D80

2 Stage D80, Electrically Heated Instruction Manual

Serial No. D80/548/02/09

Page 11 of 20

Rotajet Systems

TOP SPINDLE ASSEMBLY STRIPPING PROCEEDURE

RECIPROCATING SPRAY ARM

REFER TO DATA SHEET 972

Note! 1) Machine should be isolated from power before work commences and the

temperature inside the cabinet should be down to a maximum of 43°C before personal enter

the cabinet. On pneumatic sliding door models, the door should be securely propped open

before entry.

Note! 2) Before stripping the top spindle assembly, mark the position of the top bearing-

locating angle where it fits into the channel fabrication that is welded to the top of the

machine.

1. Remove the reciprocating arm guard.

2. Remove the top bearing (Item A) complete with mounting angle.

3. Remove bottom bearing (Item B) from bearing plate.

4. Remove bearing plate. Note! Bolts pass through top of machine and slide up and off

the spindle (Item G)

5. Remove final seal (Item C) from bearing plates and replace with new one, taking care

not to damage the new seal.

6. Locate grub screw in deflector plate (Item H), the removal of which will allow the

spindle to be lowered into the machine and out of the deflector plate.

7. Separate the pump feed pipe union, knock out dowel (if fitted) and remove bush

housing from machine, remove phosphor bronze bushes and replace with new.

RE-ASSEMBLY PROCEDURE

Re-Assembly sequence onto machine

1. Assemble housing complete with bushes, (Items D, E & F) onto feed pipe from pump

using union provided, ensuring bolt holes and centre hole for spindle are aligned

correctly.

2. Fix deflector plate (Item H) onto spindle with Allen screw located into the spindle

groove.

3. Using silicone sealer on underside of bearing plate to form a gasket between the plate

and the machine top, carefully slide the bearing plate over the spindle ensuring that no

damage is done to the lip of the final seal (Item C) and that it is correctly located onto

the spindle. (Liquid soap may assist this procedure)

4. Secure the 4 bolts, fixing housing and bearing plate through the machine top.

Page 12: ROTAJET D80

2 Stage D80, Electrically Heated Instruction Manual

Serial No. D80/548/02/09

Page 12 of 20

Rotajet Systems

5. Slide bottom bearing (Item B) onto spindle and fix with 4 screws,

leaving them hand tight. It is important to use the same screws that were removed.

6. Slide top bearing (Item A) onto spindle and fix with screws to angle iron, then fix

angle iron to channel fabrication as original. (See introductory note 2)

7. Tighten all bearing fixings, but not the grub screws onto the spindle.

8. From the inside of the machine, apply a firm upwards pressure on the spindle to

ensure the top face of the spindle is in contact with the face of the thrust bush (Item

D). Keeping this pressure on, fix one of the bottom bearing grub screws onto the

spindle and dimple the other screw. Repeat for first screw on bottom bearing and for

both screws on top bearing.

9. Position rotation indicator flag on top of spindle.

10. Fix spray arms onto unions inside the machine and spin assembly to ensure ease of

rotation and that the drop arms do not foul on the machine sides or the workbasket

when rotated.

11. Re-establish power, remove door props & close the door.

12. Operate the ‘Cycle Start’ button and observe rotational speed of spray arms, this

should be 4 to 5 full cycles per minute for optimum cleaning efficiency and minimum

wear. Adjust incoming air pressure as required to achieve this. If operating speed is

set to high, damage to the Rack & or Pinion may result.

13. Open pressure regulator gradually and increase pressure until reciprocating arm starts

to move, it may be necessary to tap the rack support brackets to ensure proper

alignment and obtain smooth operation.

14. A speed of 3 to 4 actuations per minute should be aimed at and when this is achieved,

lock the pressure regulator at this setting.

15. When the machine reaches operating temperature, re-check the spray arm operation to

ensure nothing has changed* and the re-fit the guard.

Note 1* Bringing the machine up to operating temperature may slightly tighten or distort

settings, if this occurs re-do 14 to 16.

Note 2. For renewal of top seal only, disregard items 1 – 2 & 10

Page 13: ROTAJET D80

2 Stage D80, Electrically Heated Instruction Manual

Serial No. D80/548/02/09

Page 13 of 20

Rotajet Systems

Data Sheet 2 – Bottom Spinner Assembly

Construction Details & Spare Parts Information

Comprises a robust rotating jet pipe assembly fitted with removable spray jets designed to give

an all round wash to the underside of the components by jetting upwards. The pipe is a one-

piece assembly carried by phosphor bronze bushes and mounted on a centre spindle located in

the base of the cabinet and secured in position by bolts. The top plate secured by two small

screws holds the pipe assembly on to the spindle.

The lower spray arm has one way rotation achieved by means of propulsion jets located along

the sides of the pipe in the form of 5mm tapped holes fitted with blanking screws, one or more

of which may be opened to effect rotation of the arm when the pump is activated.

Screws are removed/replaced as necessary to increase or decrease the rotational speed; the

further from the centre the propulsion jet is located, the faster the arm will spin. When the

machine is new, or new bearings have been fitted it is normally necessary one or more of the

outer screws to achieve rotation, however when the machine has been run for a few hours, the

spray arm will become much easier, the outer holes should then be blanked off and an inner

screw be removed.

Movement of the lower spray arm can be confirmed by setting the arm in a known position

(i.e.) straight across the cabinet or corner to corner, then running the machine briefly and

observing if a change of position has occurred. If no movement has occurred, a further inner

screw should be removed. This should be done progressively from the inside, the aim being to

get the spray arms to rotate continuously, but as slowly as possible. A screwed end cap is

provided at each end of the arm to facilitate flush through cleaning.

Renewal of Bushes The old bushes should be ‘Drifted’ out of their housings, taking care not to damage the

housing bore. New bushes should then be pressed into position.

Page 14: ROTAJET D80

2 Stage D80, Electrically Heated Instruction Manual

Serial No. D80/548/02/09

Page 14 of 20

Rotajet Systems

Safety Note! � Service work must not be carried out inside the wash cabinet when

the temperature in the sump is at 43°C or above.

� The machine must be isolated and the isolator locked off, before

entering or working inside the wash cabinet for any reason.

� The wash cabinet door must be securely propped open before

personnel enter to carry out maintenance work.

� Personnel must ensure the sumps are fully drained before

removing the clean out doors.

� Operators and nearby personnel must wear suitable protective

clothing, especially eye protection when dispensing or handling

chemical products and when checking that Filter and Door seals

are secure.

� Operators must wear eye protection when unloading components

from the machine.

� Operators must ensure no personal are local to the machine when

the basket is been loaded or unloaded.

� When the basket is been loaded or unloaded the operator must

have a clear line of sight to the basket and be within 0.5 meter of

the control panel allowing easy access to the basket stop button.

� Management must ensure operators & service personnel are fully

aware of the above