STRONG CONNECTIONS CERID ® TITANIUM-ZIRCONIUM CERAMIC

Upload: vokhanh

Post on 05-Oct-2018

216 views

Category:

Documents


0 download

TRANSCRIPT

WIE EINROX-CERA – DREIFACH STARKSTRONG CONNECTIONS

CERID® TITANIUM-ZIRCONIUM CERAMIC

ROX-CERA

2 |

h Innovative ceramic surface h Wider range of indications h Enhances patient compliance

DISCOVER ROX-CERA

| 3

A STRONG CONNECTION ROX-CERA Cerid®

The ROX-CERA Cerid® implants developed by DENTAL RATIO exceed the fracture and fatigue resistance of similar pure titanium implants and are characterized by a good osseointegration.

The core of the OKTAGON® ROX-CERA implants is made of titanium Grade 5 and has a biological high compliant ceramic coating, which supports a long-term osseointegration and enables a secure bone healing.

The ceramic coating is specially customized to the different biological and mechanical requirements of the endosseous and trans-gingival areas.

h Made of titanium Grade 5 ELI (approx. 30% higher tensile strength vs. titanium Grade 4)

h High biological compliance Cerid® 44 0 (titanium-zirconium-oxide) coated in the endosseous area

h Cerid® 45 ON (titanium-niobium-oxynitride) coated in the trans-gingival area

4 |

STRUCTURES – THAT DIFFER

TITANIUM-ZIRCONIUM-OXIDE Coating – friction corrosion protection

The endosseous part of the implants is provided with a cera-mic, dark, bio-compatible wear and corrosion protection layer of Cerid® 44 O.

This specially, for medical implants, developed coating is used for various medical products. The oxides of zirconium are thermo-dynamically and bio-chemically significantly more stable than the titaniums and so, avoid friction corrosion.

Through the titanium zirconium oxide ceramic coating, Cerid® 44 O, the shear strength of the surface is enhanced by the factor > 100 compared to the pure titanium oxide surface. The bio-compatibility index (BI) of the coating is nearly 1 (compared to titanium: BI > 0.3) Source: Prof. Dr.-Ing. R. Thull et.el, Biomed. Tech.

Cerid® 44 O

The BI reflects the part of native absorbing proteins to the total quantity of the absorbed proteins on a foreign material.

1

0.8

0.6

0.4

0.2

0

Ti Ti, Zr O2 Ti Nb On Co Cr Mo Stainless

Bio-compatibility index of different implant materials

CHARACTERISTICS OF THE Cerid® 44 O LAYERLayer thickness 3 - 7 µm

Structure x-ray amorphous and as a gradient set out so that a metallurgical bond is produced between the layer and the base material

Composition titanium, zirconium, nitrogen, oxygen, carbon (< 1%)

Shear strength FT > 300 N/mm²

The high BIO-COMPATIBILITY ensures a good tolerability for sensitive patients and assures a high security.

| 5

STRUCTURES – THAT DIFFER

Cross-grind with dense nano-scaled titanium-niobium-oxynitride-ceramic layer Cerid® 45 ON on titanium Grade 5

REM picture of Cerid® 44 O titani-um-zirconiumoxide ceramic layer

Cerid® 45 ON TITANIUM-NIOBIUM-OXYNITRIDE Coating – as antiplaque surface

The trans-gingival part of the implants is provided with a sponta-neous self-passivating, bio-chemical high stable titanium-niobium-oxynitride layer of Cerid® 45 ON.

The layer is light gold, very hard, H > 2000 HV0.1 (compared to titanium: H = 300 HV0.1) and possesses a high bio-chemical stability. The layer hardness offers protection against injuries through instruments during surgery.

As the picture below shows, the layer has a very smooth surface that counteracts on eventual dental plaque agglomeration.

Clinical observations confirm that the cervical accumulation of plaque on the titanium-niobium-oxynitride-ceramic surface is sig-nificantly reduced compared to a titanium surface.

CHARACTERISTICS OF THE Cerid® 45 ON LAYERLayer thickness 3 - 7 µm

Structure x-ray amorphous and as a gradient set out so that a metallurgical bond is produced between the layer and the base material

Composition titanium, niobium, nitrogen, oxygen, carbon (< 1%)

Shear strength FT > 300 N/mm²

6 |

COMPARISON OF TENSILE STRENGTH

1) Values from the acceptance test certificate EN 10204/3.1

Tensile strength

Tens

ile s

treng

th (M

Pa)

1000

800

600

400

200

0

Titanium Grade 41) Titanium Grade 51)

| 7

Cerid® coatings on implants have excel-lently proved themselfs for more than 15 years on more than one million patients and help to improve the quality of life.

ROX-CERA Cerid®

MECHANICAL CHARACTERISTICS

h the fracture and fatigue resistance exceed those of similar titanium implants

h The high shear strength (FT > 300 N/mm²) prevents the abrasion of tiny particles and their accumulation in the peri-implant tissue

ROX-CERA Cerid® implants with reduced diameter suit for following indications

h Single tooth restoration in the front tooth and premolar region

h Bridges on two ROX-CERA implants without interlocking with bigger implant diameters

h Prosthesis on two ROX-CERA implants in the lower jaw

INDICATIONS

8 |

Implants as replacement of lost teeth belong to the standard repertoire of modern dental medicine today. On a purely technical point of view, this thera-py represents a routine procedure for an experienced surgeon. Many patients opt for a dental implant, but fear the intervention if a bone augmentation should be required.

ROX-CERA implants with reduced diameter

h enlarge your treatment options

h enable a less invasive intervention

h avoid a bone augmentation in many cases

h preserve blood vessels and vital structures through smaller drill holes

h allow shorter treatment times

h suit for patients with horizontal limited bone availability

| 9

HIGH PATIENT ACCEPTANCE

LESS INVASIVE

ADVANTAGES FOR YOU AND YOUR PATIENTSPatients who fear an implant treatment and a bone augmentation with transplant? ... or high costs?

The good osseointegration properties of the ROX-CERA Cerid® implants combined with reduced endosseous diameters contribute to reduce the complexity of the treatment as a whole, avoid invasive bone augmentations and supply a high patient acceptance.

BONE LEVEL NC/RCItem no.22200 BL NC ROX-CERA implant Ø 3.3 mm, L 8.0 mm22201 BL NC ROX-CERA implant Ø 3.3 mm, L 10.0 mm22202 BL NC ROX-CERA implant Ø 3.3 mm, L 12.0 mm

22060 BL RC ROX-CERA implant Ø 4.1 mm, L 8.0 mm22061 BL RC ROX-CERA implant Ø 4.1 mm, L 10.0 mm22062 BL RC ROX-CERA implant Ø 4.1 mm, L 12.0 mm

TISSUE LEVEL RPItem no.

72200 TL RP ROX-CERA implant Ø 3.3 mm, L 8.0 mm72201 TL RP ROX-CERA implant Ø 3.3 mm, L 10.0 mm72202 TL RP ROX-CERA implant Ø 3.3 mm, L 12.0 mm

31169 TL RP ROX-CERA implant Ø 4.1 mm, L 8.0 mm31170 TL RP ROX-CERA implant Ø 4.1 mm, L 10.0 mm31171 TL RP ROX-CERA implant Ø 4.1 mm, L 12.0 mm

10 |

STRONG CONNECTIONS

CERID® TITANIUM-ZIRCONIUM CERAMICROX-CERA

| 11

Our staff members stand at your entire disposal for a personal consultation.

Prices in EUR, ex works and subject to VAT. Our general terms and conditions are applied (www.dental-ratio.de). Misprints and errors excluded.

Billing address

Item no. Quantity

Product catalog 1

Order fax+49 2173 39800-20

DRS International GmbH Raiffeisenstr. 15 a

40764 Langenfeld | Deutschland

Phone +49 2173 39800-0 Fax +49 2173 39800-20

Email [email protected] Internet www.dental-ratio.de

Personal consultation appointment is desired, if possible on: ____ . ____ . ________

Send me additional info materials

____________________________________________________ Name, Surname

____________________________________________________ Clinic/Lab

____________________________________________________ Email

____________________________________________________ Signature

____________________________________________________ Date

Stamp

Thank you for your interest in DENTAL RATIO. We look forward to your questions and suggestions and we would be happy to assist you in any way.

Artik

elnr

. 906

11 ·

ISSU

E 04

/201

7

ASK SMART

Phone +49 2173 39800-0Fax +49 2173 39800-20Email [email protected] http://www.dental-ratio.deSocial http://facebook.com/DentalRatio

DRS International GmbHRaiffeisenstr. 15 a

40764 Langenfeld

Germany

QUALITY – MADE IN GERMANYC0044

fotolia © Seemensch@24387420 | Kurhan@91958157 | larshallstrom@104156066-99820451