rpc dqm status cimmino, m. maggi, p. noli, d. lomidze, p. paolucci, g. roselli, c. carillo

17
RPC DQM status Cimmino, M. Maggi, P. Noli, D. Lomidze, P. Paolucci, G. Roselli, C. Carillo

Upload: edmund-hall

Post on 18-Jan-2016

215 views

Category:

Documents


0 download

TRANSCRIPT

Page 1: RPC DQM status Cimmino, M. Maggi, P. Noli, D. Lomidze, P. Paolucci, G. Roselli, C. Carillo

RPC DQM status

Cimmino, M. Maggi, P. Noli, D. Lomidze,

P. Paolucci, G. Roselli, C. Carillo

Page 2: RPC DQM status Cimmino, M. Maggi, P. Noli, D. Lomidze, P. Paolucci, G. Roselli, C. Carillo

Anna, David e Pierluigi

DQM meeting - 26 feb 08 2

Online General Plan I

Large set of histograms chamber by chamberCluster Size, Nr of Digis, Multiplicity, BX, Occupancy

Small set of Summary histograms 5+1 Cluster Size by wheel & barrel

60 Occupancy by sectors

5 2D Occupancy by wheel

Quality test: statistical analysis, alarms, results in output file (ready)

histo comparision, output read from GUI, file repository (on going)

General Web based DQM GUI (WBM today) display Histograms, alarms and Qtest output file

Page 3: RPC DQM status Cimmino, M. Maggi, P. Noli, D. Lomidze, P. Paolucci, G. Roselli, C. Carillo

Anna, David e Pierluigi

DQM meeting - 26 feb 08 3

Online General Plan II

RPC RenderPluginscolored histograms/plots (ready for summary histos)

alarm and warning text on the histo\plot (March)

reference histograms\plots (April)

could be more !!

Store output root files and ascii files in the CMS repository (April)

Online documentation for people in shift (operation manual, instruction and examples) (twiki page to update and improve)

Page 4: RPC DQM status Cimmino, M. Maggi, P. Noli, D. Lomidze, P. Paolucci, G. Roselli, C. Carillo

DQM meeting - 26 feb 08 4

RPC DQM group

Offline DQM I

What we have nowCluster Size, Nr of Digis, BX, Occupancy

Chamber and Trigger Efficiency (G. Roselli)

Chamber Noise

What we are planning to do2D efficiency (Radiography) (Napoli)

trigger data and DB usage (May)

Run quality studies

We have to estimate/measure the numbers and the performance of the offline DQM (how many histo/plot, CPU time….)

Page 5: RPC DQM status Cimmino, M. Maggi, P. Noli, D. Lomidze, P. Paolucci, G. Roselli, C. Carillo

DQM meeting - 26 feb 08 5

RPC DQM group

Offline DQM II

We need an accurate offline trigger studies (Giuseppe) and correlate the results with the detector results

We need to access non event-data from the condition database and used them for more accurate analysis and checks.

Offline calibration to send back to ORCON (online):Dead and noisy strips !!

Efficiency chamber by chamber ?

DQM summary results can be stored in the ORCOF

central GUI and/or TBrowser to see histos

Page 6: RPC DQM status Cimmino, M. Maggi, P. Noli, D. Lomidze, P. Paolucci, G. Roselli, C. Carillo

DQM meeting - 26 feb 08 6

RPC DQM group

RPC DQM Plan for next GR

RPC Online part is almost ready. Few technical problems will be fixed soon - David

3-D occupancy plots by sector are now ready (new) - David

WEB GUI based on WBM is now ready

First Qtest prototype is ready (output ascii file) (new) - Annawe would like to merge DQMMonitorDigi (where the histograms are produced) and Qtest module (where the analysis is done) in only one module.

will check monitoring elements after every 1.000\10.000 entries (we have to discuss this ), in any case it is configurable by config. file

it produces output ascii file, in the near future WEB GUI will read it.

A first prototype of the RPCRenderPlugins is now ready (decorate or to write text on histograms) - David

OFFLINE: working on the 3-D efficiency histograms (chamber radiography) and on Trigger/Chamber efficiency (Giuseppe) (new)

Page 7: RPC DQM status Cimmino, M. Maggi, P. Noli, D. Lomidze, P. Paolucci, G. Roselli, C. Carillo

DQM meeting - 26 feb 08 7

RPC DQM group

QTests status and plan (A. Cimmino)

Dead Strip test: performed on the occupancy plots made chamber by chamber. Output ascii file and histogram with dead strips.

Mismatches with already known dead strips are reported. (80% ready)

Occupancy Difference Test: it retrieves reference histograms for each chamber and compares bin by bin. Output will be ascii file and/or histograms

Multiplicity/Cluster size:

It checks the last set of histograms with the references and produce an output file/plots.

It checks if the multiplicity is compatible in an “a priori” defined range. It checks how much the multiplicity of each chamber deviates from the average calculated wheel by wheel.

Page 8: RPC DQM status Cimmino, M. Maggi, P. Noli, D. Lomidze, P. Paolucci, G. Roselli, C. Carillo

DQM meeting - 26 feb 08 8

RPC DQM group

Sector Occupancy (new)

Dead strips

Page 9: RPC DQM status Cimmino, M. Maggi, P. Noli, D. Lomidze, P. Paolucci, G. Roselli, C. Carillo

DQM meeting - 26 feb 08 9

RPC DQM group

Sector Occupancy (new)

Dead strips

Using RPCRenderPlugins

Page 10: RPC DQM status Cimmino, M. Maggi, P. Noli, D. Lomidze, P. Paolucci, G. Roselli, C. Carillo

DQM meeting - 26 feb 08 10

RPC DQM group

WMB Interface

WBM will be used by CMS only for the history plots (summary info from DB) !!!New Online and Offline GUI is almost ready (with WEB interface)

Page 11: RPC DQM status Cimmino, M. Maggi, P. Noli, D. Lomidze, P. Paolucci, G. Roselli, C. Carillo

DQM meeting - 26 feb 08 11

RPC DQM group

ClusterSize, Occupancy, BX,

BX

Global Ocupancy by Wheel

Number of Digi

Cluster Size by Chamber

Occupancy by Chamber

Page 12: RPC DQM status Cimmino, M. Maggi, P. Noli, D. Lomidze, P. Paolucci, G. Roselli, C. Carillo

Offline DQM questions1. Which are the offline DQM modules (existing or planned) to

be run? 2. What is the status of the code development and readiness

for deployment?• RPCMonitorDigi ( RPCEfficiencyFromTrack.cc,  RPCMonitorDigi.cc

RPCMonitorEfficiency.cc) 90% ready• RPCMonitorClient (Qtest) 30% ready• RPCMonitorModule (to delete)

3. Which are thepackages that we need to include?

//DataFormatsDataFormats/RPCDigi/DataFormats/MuonDetId/DataFormats/RPCRecHitDataFormats/GeometrySurfaceDataFormats/GeometryVectorDataFormats/Common

//GeometryGeometry/RPCGeometry/Geometry/Records/Geometry/CommonDetUnit/

//FrameWorkFWCore/MessageLogger/ FWCore/Framework/FWCore/ParameterSet/FWCore/ServiceRegistry/

//DQMServicesDQMServices/CoreDQMServices/NodeROOTDQMServices/DaemonDQMServices/UIDQMServices/ComponentsDQMServices/WebComponentsDQMServices/ClientConfig

Page 13: RPC DQM status Cimmino, M. Maggi, P. Noli, D. Lomidze, P. Paolucci, G. Roselli, C. Carillo

Offline DQM questions4. It would be great to have some quantitative estimates of

a) the number of histograms and binsSummary histos/bins: 69 / 6.320    Occupancy by Weel: 5 histo 480 bins    Sector Occupancy: 60 histos 5.760 bins    Cluster Size: 4 histos 80 bins

Histos by chambers: 11.164 / 1.010.250Barrel:

1D. ~ 4800 histos, 700800 bins(ClusterSize, Number of Clusters, Number of Digi, BX, Occupancy)2D. ~1920 histos, 76800 bins(ClusterSize vs Strips, BX vs Strips)barrel total ~6789 histograms &  860720 bins

Endcap :1D. ~ 3125 histos,  309450 bins(ClusterSize, Number of Clusters, Number of Digi, BX, Occupancy)2D. ~ 1250 histos, 120000 bins(ClusterSize vs Strips, BX vs Strips)

Efficiency by chambers: 10.000 / 960.000

Page 14: RPC DQM status Cimmino, M. Maggi, P. Noli, D. Lomidze, P. Paolucci, G. Roselli, C. Carillo

Offline DQM questions

5. the memory and CPU consumption ?

we don’t have this estimation – working on

6. the number of events required for good statistics:

1 milion of muons for the efficiency by strip

10 K of muons for the cluster size, multiplicy, noise and occupancy (by chamber)

120 K muons for the summary plots (by wheel…)

Page 15: RPC DQM status Cimmino, M. Maggi, P. Noli, D. Lomidze, P. Paolucci, G. Roselli, C. Carillo

RPC

Page 16: RPC DQM status Cimmino, M. Maggi, P. Noli, D. Lomidze, P. Paolucci, G. Roselli, C. Carillo

RPC Detector Status

We are now working on the definition of a detector status by sector wheel barrelThe RPC DS will be based on the detector occupancy and/or on the trigger rate Right now we will use only the detector occupancy checking:

average occupancy per chamber shape of the occupancy histogram the number of dead strips (“new” and “old”)

In any case we need to check also the DCS will provide information about the HV, LV and Gas status (FSM and alarm)

Page 17: RPC DQM status Cimmino, M. Maggi, P. Noli, D. Lomidze, P. Paolucci, G. Roselli, C. Carillo

DQM meeting - 26 feb 08 17

RPC DQM group

Conclusions

Online RPC DQM is almost ready: new 2D histograms (occupancy)

still working on more summary plots

quality test on going (dead strip ready)

Offline RPC DQM contains also: detector efficiency (ready)

trigger efficiency (working on)

Almost 22 K histograms 2,2 milions of bin