    Concerned componentsInjection Control Units (ICUs) of WärtsiläRT-flex96C-B and RT-flex84T-D engines.

    Current situationThis Technical Bulletin provides importantinformation about fault finding, repair and

    maintenance possibilities of an ICU onboard or ashore.

    OutlookDuring the second half of this year 2012,Wärtsilä will introduce new MaintenanceConcepts for ICUs. The implementation ofthe new concepts will allow to extend theinspection and maintenance intervals forthe ICU (TBO) and thus to lower theoperating cost.

    Note

    Please consult also the GeneralInformation bulletin RT-119, informing youin detail about the componentremanufacturing services.

    Wärtsilä Switzerland Ltd. Tel (24h): +41 52 262 80 10

    PO Box 414 Fax: +41 52 262 07 31

    CH-8401 Winterthur [email protected]

    Information to all Owners and Operators ofWärtsilä RT-flex96C-B and RT-flex84T-D engines

    Next opportunityTroubleshooting & maintenanceon Injection Control Unit (ICU) 

    RT-124

    Issue 1, 03.04.2012

    Wärtsi lä low-speed engines

    Services 2-stroke 

    TECHNICAL

    BULLETIN

  • 8/20/2019 RT-124 Troubleshooting %26 Maintenance on Injection Control Unit

    2/21

     

    RT-124TECHNICAL BULLETIN

    Issue 1, Page 2 / 17

     

    Contents

    Page

    Introduction 2 

    Terms and glossary 2 

    Conditions for effective troubleshooting 3 

     Alarms 4 

    Countermeasures 4 

    ICU storage 12 

    ICU replacement criteria 13 

    Maintenance on ICU size IV 16 

     Appendix 17 

    Contacts 17 

    Introduction

    This guideline summarises the checks recommended to investigate possible

    causes in case of alarms indicating improper function of the ICU.

    Unnecessary costs may be avoided by simple rectifying actions instead of an ICU

    replacement and shipping to a Wärtsilä service centre; e.g. exchange of available

    spare parts or a proper understanding of the alarms.

    Should a problem not be rectified by the described countermeasures, however,

    replacement of the ICU must be taken into consideration.

    In Service Bulletin RT-flex-06, “Reconditioning of Injection Control Unit”, some of

    the possible failures are described. The description below repeats therecommendations and provides an update by including the latest available

    experience.

     At tention:

    When working on ICUs or the fuel oil system in general, the fuel oil system must

    be pressure-less! The engine must be stopped and the fuel booster and bearing

    oil pumps stopped.

    Safety measures are to be taken according to the Maintenance Manual Group 0,

    Chapter 0011–1/A1, delivered with the engine.

    Furthermore this Technical Bulletin offers information on the maintenance criteria

    for the Injection Control Unit (ICU). It is applicable for RT-flex96C-B and RT-

    flex84T-D engines. The Time Between Overhaul (TBO) of the ICU is given for

    normal operating conditions with fuel oils within the specifications (refer to the

    Operating Manual). After this period, maintenance will become necessary.

    Terms and glossary

     Abbreviation Name / Part

    ICU Injection Control Unit

    ICV Injection Control Valve

    FQP Fuel Quantity Piston

    FQ sensor Fuel Quantity Sensor

    FQS Fuel Quality Setting

  • 8/20/2019 RT-124 Troubleshooting %26 Maintenance on Injection Control Unit

    3/21

     

    RT-124TECHNICAL BULLETIN

    Issue 1, Page 3 / 17

     

     Abbreviation, cont. Name / Part

    RV2 Rail Valve

    PCV Pressure Control Valve

    WECS-9500 Wärtsilä Engine Control System, type 9500

    WECS-9520 Wärtsilä Engine Control System, type 9520

    E85 WECS control cabinet E85

    Size IV Describes the size of the rail unit which covers theRT-flex96C-B and RT-flex84T-D engines

    Table 1

    Conditions for effective troubleshooting

    Before an effective troubleshooting of ICU related issues is possible, other

    causes of malfunction must be excluded, see Table 2.

    Component WECS alarms Descript ion

    1. Fuel railpressurefailures

    ME fuel rail pressure sensor #1+2meas. failureME fuel rail pressure meas. failure:Diff. highME fuel rail pressure highME fuel rail pressure lowME fuel rail pressure very low

    In case of fuel over-supplyfrom high pressure pumps,the fuel rail pressure will belimited by the PCV. Highfluctuations of the fuel railpressure possible.

    2. Fuel pumpactuatorfailure

    ME fuel pump actuator failure If one actuator fails, thecorresponding pump willdeliver maximum capacity.This can cause a similarbehaviour as in previouscase 1.

    3. Insufficientpump capacity

    WECS fuel command limiter active Any failure on the fuel oilsystem will change the ICUperformance or render itcompletely inoperable.

    4. Control oilsystemfailures

    ME control oil pressure meas. failureME control oil pressure lowME control pressure very lowME control oil pump # failure

     Any failure on the control oilsystem will change the ICUperformance or render itcompletely inoperable.

    5. Rail unitsteam tracingfailures

    N/A In case of HFO use, rail unittrace heating must beoperational.

    6. Engineperformance

    N/A All pressures andtemperatures must conformto the operating data sheet.

    7. Fuel systemfailures

    N/A Fuel viscosity at engine inletconforms to the specification(13 to 17 cSt).Fuel pressure at engine inletconforms to operating datasheet.

    Table 2

  • 8/20/2019 RT-124 Troubleshooting %26 Maintenance on Injection Control Unit

    4/21

     

    RT-124TECHNICAL BULLETIN

    Issue 1, Page 4 / 17

     Alarms

    Various alarms can appear for several seconds during engine start, in particular

    after maintenance work on the fuel injection equipment or on the hydraulic oilsystem.

    The possible alarms are listed in Appendix 1.

    Only if one of these possible alarms persists, troubleshooting as listed in

     Appendix 1 should be performed. To each listed alarm a possible cause and

    remedy is described. Depending on the result and recommendation the

    countermeasure should be performed.

    Countermeasures

    Depending on the outcome of the troubleshooting and the proposed remedy in

    the chapter “Alarms, Appendix 1”, the respective countermeasure should be

    carried-out.

    Countermeasure 1 – Fuel quantity sensor

    The piston rod on the Fuel Quantity Piston (FQP) may require cleaning and

    removal of carbon deposits to ensure a smooth movement.

    1. Turn off the power for the respective unit in the E85 box.

    2. Remove the cable support for the Fuel Quantity Sensor (FQ sensor) cabling,

    see Figure 1.

    Removal of cable support

    1 2

    1. Cable support location, 2. Remove cable support

    Fig. 1

    3. Disconnect the cabling for the FQ sensor.

    4. Remove the housing, see Figure 2.

    −  Loosen the four fixing bolts (2), i.e. hexagon socket head cap screws

    M10x60.−  Remove the housing (1) in horizontal direction in order to avoid damaging

    the FQP rod.

  • 8/20/2019 RT-124 Troubleshooting %26 Maintenance on Injection Control Unit

    5/21

     

    RT-124TECHNICAL BULLETIN

    Issue 1, Page 5 / 17

    Removal of housing

    1. Housing, 2. Four fixing bolts M10x60

    Fig. 2

    5. Cleaning the FQP rod, see Figure 3 and 4.

    Material needed for cleaning:

    −  Scotch–Brite™.

    −  Brake cleaner, Neoval®, WD40®, Diesel or similar available solvent.

    Note:

    It is not unusual to find condensed water in the housing area. The condensed

    water does not have any influence for the sensor function.

    During general engine operation only about 50 to 70% of the FQP stroke isutilised. As a consequence, fuel deposits will build up on the unused part of

    the piston rod, see Figure 3. If a sudden increase in stroke occurs, the fuel

    deposits can lead to a sticking piston in its maximum position.

    Contaminated piston rod

    1. Fuel deposits on piston rod

    Fig. 3

    1

    21

  • 8/20/2019 RT-124 Troubleshooting %26 Maintenance on Injection Control Unit

    6/21

     

    RT-124TECHNICAL BULLETIN

    Issue 1, Page 6 / 17

    Cleaning procedure:

    −  Soak the deposits with cleaning solvent.

    −  Use Scotch–Brite™ or similar to remove deposits.

    −  Carefully clean the piston rod from any particles.−  Lubricate the piston rod with lubricating oil.

    Cleaning of piston rod

    1. Cleaning with Scotch–Brite™, 2. Cleaning solvent, 3. Clean piston rod with

    cloth

    Fig. 4

    6. Confirm movement of the FQP.

     After cleaning, confirm smooth running of the piston by hand (full stroke and

    turn 360°).

    Free movement check of p iston

    1. Full stroke movement, 2. Turn 360°

    Fig. 5

    Note:

    If a new Fuel Quantity Sensor (FQS) was delivered and needs to be installed,read the fitting instructions delivered with the new FQS. The instruction is located

    in the same box as the sensor with measurement tube and other consumable

    parts.

    32

    2 1

    1

  • 8/20/2019 RT-124 Troubleshooting %26 Maintenance on Injection Control Unit

    7/21

     

    RT-124TECHNICAL BULLETIN

    Issue 1, Page 7 / 17

    7. Connecting elements

    Two different designs of connecting elements are present on the Wärtsilä

    ICUs. The old type will be replaced by the new connecting element type at the

    time the old ICU is returned to Wärtsilä for remanufacturing.The difference of the connecting elements is that the old type is screwed with

    a locking nut, see Figure 6, and the new type is bolted together with a

    hexagon screw, see Figure 7.

    7a) Old  type connecting element:

    Check if the measurement tube (1) is correctly tightened.

    If the torque is not correct, retighten the measurement tube (1) against the set

    screw (4) of the piston rod (2) with a torque of 5 Nm and the M5 locking nut (3)

    with a torque of 2 Nm.

    Old type connecting element

    1. Measurement tube, 2. Piston rod, 3. M5 nut, 4. Set screw, 5. Torque spanner

    Fig. 6

    7b) New type connecting element:

    Check if the M5x45 screw (4) is correctly bolted and not loose. Do not

    retighten the M5x45 screw.

    In case the M5x45 screw is loose, remove the screw and clean the threads

    thoroughly. Apply securing agent (Loctite 648), re-install the screw and tighten

    it with 6 Nm. Make sure the two distance sleeves (3) are in place.

    New type connecting element

    12 4 3 51

    1

    1. Measurement tube, 2. Piston rod, 3. Distance sleeves, 4. Screw M5x45,

    5. Torque spanner, 6. Flat surface for spanner size 8 mm

    Fig. 7

    1435

    2 4 16 3

  • 8/20/2019 RT-124 Troubleshooting %26 Maintenance on Injection Control Unit

    8/21

     

    RT-124TECHNICAL BULLETIN

    Issue 1, Page 8 / 17

    Note:

    The piston rod has to be blocked by an 8 mm spanner at the flat surface behind

    the connecting element depending on the piston type. Special care has to be

    taken in order to prevent damaging the piston rod.

    8. Reassembly of the housing:

    Place the greased O-ring (1) on the intermediate flange (2) and fit the

    housing (3).

    Reassembly of housing

    1. O-ring, 2. Intermediate flange, 3. Housing, 4. Four fixing bolts M10x60 –

    tighten crosswise with 30 Nm

    Fig. 8

     After installing the housing (3), check that the aluminium measurement tube is

    in the centre of the housing. Small adjustments can be done by tightening the

    four fixing bolts (4) additionally, see Figure 8.

    9. Plug in the cable and re-install the cable support.

    Countermeasure 2 – Fuel quantity sensor replacement

    1. Disassembly procedure of the FQS as described in Countermeasure 1,

    Point 1 to 3.

    2. Slacken and remove the six screws (1) on the holder (2) and FQS (3).

    Removal of holder and fuel quantity sensor

    1. Screws, 2. Holder, 3. Fuel Quantity Sensor (FQS), 4. Housing

    Fig. 9

    4

    431 2

    3

    1

    2

  • 8/20/2019 RT-124 Troubleshooting %26 Maintenance on Injection Control Unit

    9/21

     

    RT-124TECHNICAL BULLETIN

    Issue 1, Page 9 / 17

    3. Replace the FQS with the new one.

    Note:

    The new Fuel Quantity Sensor (FQS) is located in a special box. Read the fittinginstructions delivered with the new FQS. The instruction is located in the same

    box as the sensor with measurement tube, holder, O-rings and other consumable

    parts.

    •  Brief assembly procedure, extract from the detailed instructions delivered with

    the new FQS:

    1. Remove the fuel quantity sensor (1) from the special box (2).

    2. Place the greased O-ring (3) on the FQS (1) and install the sensor.

    Location of the new fuel quantity sensor

    1 1

    1. FQS, 2. Special box, 3. O-ring

    Fig. 10

    3. Screw the holder (2) with the FQS (3) down on the housing (4).

    Reassembly of the fuel quantity sensor with holder

    1. Screws, 2. Holder, 3. Fuel Quantity Sensor (FQS), 4. Housing

    Fig. 11

    4. Tighten the six screws (1) of the holder (2) and FQS (3) crosswise with

    20 Nm, see Figure 11.

    5. Finally plug in the cable and re-install the cable support.

    32

    42

    1

    3 1

  • 8/20/2019 RT-124 Troubleshooting %26 Maintenance on Injection Control Unit

    10/21

     

    RT-124TECHNICAL BULLETIN

    Issue 1, Page 10 / 17

    Countermeasure 3 – Rail valve replacement

    Grease the O-rings (3) and install the rail valves (1) to the valve unit (4). Tighten

    the four screws (2) crosswise with 4 Nm.

    Remark:

    Two different mounting executions of the rail valve were applied in the past. One

    is with an intermediate mounting plate and the other is directly fixed to the ICU

    pre-control block. Today’s common execution is the one directly fixed to the ICU

    pre-control block.

    Check on your ICU if an intermediate mounting plate is installed or not.

    By replacing the rail valve, the same condition has to be maintained as before

    dismantling.Depending on the execution with or without intermediate mounting plate, the

    screw length differs:

    •  Screw length with intermediate mounting plate: M4x20

    •  Screw length without intermediate mounting plate: M4x16

    Replacement of the rail valves, execution wi thout intermediate mounting plate

    2 1

    143 4

    1. Rail valves, 2. Screws – tighten with 4 Nm, 3. O-rings, 4. Valve unitFig. 12

    Countermeasure 4 – Reset of fuel quantity piston

    Sticking Fuel Quantity Piston (FQP) in maximum position.

    In some cases the FQP can be reset by the following steps:

    1. Release Fuel Oil (FO) rail pressure by:

    −  Stopping the engine – 0 rpm.

    −  Stop the main engine FO booster pumps.

  • 8/20/2019 RT-124 Troubleshooting %26 Maintenance on Injection Control Unit

    11/21

     

    RT-124TECHNICAL BULLETIN

    Issue 1, Page 11 / 17

     

    2. Check that the FQP has returned to the minimum position by:

    −  Removing the fuel quantity housing, see Countermeasure 1 – Point 4.

    −  Pull the piston all the way out by hand.

    Note: If there is still pressure in the FO rail, the piston cannot be moved.−  Install the fuel quantity housing, see Countermeasure 1 – Point 8.

    −  Re-install the cable support.

    3. Vent the affected ICUs manually via the USER-page in flexView.

    4. Start the FO booster pumps.

    5. Start the engine.

    Countermeasure 5 – Replace and return the ICU to Wärtsilä warehouse

    If none of the above mentioned countermeasures could solve the problem, it

    should be taken into consideration to replace the ICU with a new or

    remanufactured one. Return afterwards the non-working ICU to a Wärtsiläwarehouse.

    Note:

    The process how to act when ordering or returning a non-working ICU is

    described in Technical Bulletin RT-119, Issue 1, dated 17.01.2012, entitled

    “Component remanufacturing services”.

    For your convenience find here a summary of the steps to be taken:

    1. Send an order for a remanufactured ICU to your normal Wärtsilä sales contact

    or representative.

    −  Send information about vessel name, engine type & number, required

    delivery time and place.

    −  When you return used ICUs, send information about where you intend to

    land or deliver to and running hours of ICU.

    2. You will receive an order confirmation.

    3. You will receive instructions for the return delivery, including a return delivery

    sheet. Please include ALL necessary ICU information in the sent return sheet,

    for example existing marking on ICU.

    4. Return the ICU in the special wooden transportation box, see Figure 13.

    5. Once the used ICU is received in the Wärtsilä warehouse together with the

    respective transportation box, a Credit Note will be generated as the refund fora pre-determined amount.

    The ICU must be packed and shipped in a special wooden transport box. This

    special box protects the ICU from damage and prevents any remaining fuel oil

    from leaking out.

    The box will be provided by Wärtsilä as part of the remanufacturing exchange

    concept. If required, additional boxes can be obtained through your Wärtsilä

    sales contact or representative.

    Note:

    Used ICUs shall be returned in the specially designed wooden box only, seeFigure 13. The wooden boxes are the property of Wärtsilä.

  • 8/20/2019 RT-124 Troubleshooting %26 Maintenance on Injection Control Unit

    12/21

     

    RT-124TECHNICAL BULLETIN

    Issue 1, Page 12 / 17

    Wooden transportation box

    2

    1

    1. Transportation box – property of Wärtsilä, 2. Catches for easy opening and

    closing without destroying the box and coverFig. 13

    ICU storage

    The spare parts must be carefully protected against corrosion during the storage

    time:

    •  The ICU has to be free from any dirt, oil and grease.

    Cleaning can be performed manually with the aid of chemical agents.

    •  All blind holes and tapped holes must be plugged.

    Plugs applied to holes on ICU

    1

    2

    1. Injection control unit, 2. Plugged holes

    Fig. 14

    •  Apply coating liquid (e.g. Dewatering Fluid WA) on the surfaces to be

    preserved. A brief description of the coating liquid and how to apply on the

    surfaces is mentioned in Appendix 2.

    Dewatering fluid can be brushed or sprayed on. It may be applied to moist

    surfaces. No harm is done to electronic components or plastics (exception isStyropor®). It is not necessary to remove the protective waxy film when installing

    the ICU on the engine. The waxy film will drain at temperatures above some

    80 to 90 °C.

  • 8/20/2019 RT-124 Troubleshooting %26 Maintenance on Injection Control Unit

    13/21

     

    RT-124TECHNICAL BULLETIN

    Issue 1, Page 13 / 17

    The protection by the Dewatering Fluid WA would not be necessary if the ICU is

    packed in VCI film which assures sufficient protection, see Figure 15. However,

    after transportation the VCI foil is removed and the ICU may be exposed to

    adverse climatic conditions on the vessel (intense cold, high humidity,condensation, etc.) before going into operation.

    ICUs packed in VCI film

    1

    1. ICU protected and packed with VCI film

    Fig. 15

    Note:Store the ICU in a dry room and in a wooden box and/or cover it against

    pollution.

    ICU replacement criteria

    Before evaluating the ICU for possible replacement criteria and being returned for

    remanufacturing, it is required that certain engine systems and components are

    properly maintained.

    Special attention must be given to the following systems and components:

    •  Fuel injectors in good order.•  Scavenge air system in clean condition.

    •  Pressure difference of the charge air coolers within tolerable values.

    •  No fouling on turbochargers which would reduce their performance.

     Any of the following criteria can be an indicator that the ICU is due for

    remanufacturing:

    Engine running hours Recommended maintenance approach

    36,000Remanufacturing ashore

    (Exchange parts / Remanufacturing)

    Table 3

  • 8/20/2019 RT-124 Troubleshooting %26 Maintenance on Injection Control Unit

    14/21

     

    RT-124TECHNICAL BULLETIN

    Issue 1, Page 14 / 17

    •  ICU leakages are abnormally high.

    If the leakage alarm appears, the origin has to be identified by opening the

    drain line and measuring the leakage amount from each ICU. This should not

    include leakages from tell-tale holes or from the fuel oil high-pressure pipes.•  Wear recognition on the ICU.

    The messages InjBeginDeviation Cyl#n HI  and InjBeginDeviation Cyl#n very

    HI are newly implemented into the WECS software Version 32, build 082.

    These messages are meant to warn the operator about the advanced wear

    rate inside the ICUs. The consequence of this wear is noticeable by the shape

    of the injection curves, specifically at the beginning of the curve, see

    Figure 16.

    Depending on the WECS system, the injection curves can be visualised in

    flexView as follows:

    WECS system Required steps to visualise curve

    WECS-9500Switch access level to “Service”. Password is “flexView” Click on “View”, select “Injection Curve” Select “Cylinder number”, Select “One cycle, Scan” 

    WECS-9520Click on “View”, select “Injection Graph” Select “Cylinder number”, Deselect “Cyclic, Scan” 

    Table 4

    Note:On engines equipped with WECS-9500 or WECS-9520 it is advisable to look

    regularly at the "injection curves" in flexView.

    Injection curve examples

    21

    1. Low wear and still good looking injection curve, 2. Wear signs clearly visible

    Fig. 16

  • 8/20/2019 RT-124 Troubleshooting %26 Maintenance on Injection Control Unit

    15/21

     

    RT-124TECHNICAL BULLETIN

    Issue 1, Page 15 / 17

     

    The wear at the control edges might lead to wrong interpretation of the feedback

    signal. The assumed injection begin is earlier than the real start of injection (the

    indicated assumed injection begin dead-time is calculated shorter than the real

    one). The dead-time is an essential part of information needed by the WECSsystem to inject the fuel at the correct crank angle position.

    This means if the assumed dead-time is shorter than the real dead time, the rail

    valve can be activated later in order to achieve the same injection angle. But if

    this dead-time in reality is not shorter it will lead to later injection and reduced

    Pmax. The prolonged dead-time is an indication of ICU wear. 

    In order to avoid such situations, a new method of dead-time determination has

    been developed and implemented. The WECS system can estimate what would

    be the dead-time in optimum condition. This estimation is based on the shape of

    the remaining part of the curve. The difference between the measured dead-time

    and the estimated dead-time is the so called “Injection Dead Time Deviation”.This new feature has been implemented with the software version 31 build 081.

    This deviation value is used to compensate the wrong injection angle of aging

    ICUs. Even with a worn ICU the correct injection timing is kept. However, this

    compensation cannot last forever and at some point the wear becomes higher

    than the WECS system is able to compensate. The result can be seen on the

    engine performance, namely on Pmax. These two new messages in the flexView

    are an indication that the limits of wear compensation are close. This does not

    mean that the ICU should be replaced immediately; it gives an early warning to

    the operator to have a spare one ready on board the vessel.

    Three factors are considered which influence injection timing and consequently

    the Pmax. VIT will not be considered here.

    Factors and influences to Pmax *) 

    Factor Influence

    Injection begin offsetFQS setting

    Negative offset means earlier injection and higher Pmax.Positive offset means later injection and lower Pmax.

     Automatic wearcompensation

    Extends the dead time and therefore causes earlier injectionand higher Pmax.

     Actual wear of the ICUCauses measured dead time to be shorter than real. Thisresults in later injection and lower Pmax.

    *) Table only valid for ICU “Step 1”. For the identification of the ICU see Table 6. 

    Table 5

    The WECS system can only estimate  the stage of wear based on the fuel

    quantity piston movements. The real wear is of course more complex. This is the

    reason why these are only messages and not actual alarms. Nevertheless, these

    messages are good indications that the performance of the ICU is not optimum.

    However, the engine can still run thanks to the automatic wear compensation.

    The final decision to replace the ICU should be based on the engine performancein particular, to the ability of the unit to reach the correct Pmax. Therefore the

    performance data and indicator diagrams should be checked for correct injection

    timing, combustion temperatures and pressures.

  • 8/20/2019 RT-124 Troubleshooting %26 Maintenance on Injection Control Unit

    16/21

     

    RT-124TECHNICAL BULLETIN

    Issue 1, Page 16 / 17

    Note:

    The automatic wear compensation works only on the WECS-9520 with software

    Version 32, build 082 or higher, but not on WECS-9500 systems.

    Maintenance on ICU size IV

    The general maintenance concept and the remanufacturing process will be

    described in a separate Technical Bulletin, entitled “Maintenance concepts for

    Injection Control Unit (ICU)”. The release of this bulletin is foreseen for the

    second half of this year 2012.

    It is important to distinguish between the old type or 1st generation ICU (Step 0)

    and the new type ICU (Step 1). The type of ICU for RT-flex96C-B andRT-flex84T-D can be identified by checking for a groove or recess on the outside

    of the Injection Control Valve (ICV).

    Identification marks fo r ICUs

    ICU type Identifi cation mark

    Step 0 ICVs have a straight surface

    Step 1 ICVs have a groove or a recess

    Table 6

    ICVs for RT-flex96C-B and RT-flex84T-D engines

    2 431 2

    1. Step 1 ICV with groove, 2. Groove / recess, 3. Step 0 ICV with smooth surface,

    4. Step 1 ICV installed

    Fig. 17

  • 8/20/2019 RT-124 Troubleshooting %26 Maintenance on Injection Control Unit

    17/21

     

    RT-124TECHNICAL BULLETIN

    Issue 1, Page 17 / 17

     Appendix

    1. Alarms

    2. Proposed corrosion protective product

    Contacts

    How to contact Wärtsi lä

    For questions about the content of this Technical Bulletin, or if you need Wärtsilä

    assistance, services, spare parts and/or tools, please contact your nearest

    Wärtsilä representative.

    If you don’t have the contact details at hand, please follow the link “Contact us” –

    “24h Services” on the Wärtsilä webpage:

    www.wartsila.com 

    Contact details for emergency issues

    Operational support

    For questions concerning operational issues, please send your enquiry to:

    [email protected] 

    or phone 24hrs support: +41 52 262 80 10.

    Field service

    If you need Wärtsilä Field Service, please send your enquiry to:[email protected] 

    or phone 24hrs support: +41 79 255 68 80.

    Spare parts

    If you need Wärtsilä spare parts and/or tools, please send you enquiry to:

    [email protected] 

    or phone 24hrs support: +41 52 262 24 02

    © 2012 Wärtsilä Switzerland Ltd. – All rights reservedNo part of this publication may be reproduced or copied in any form or by any means (electronic, mechanical,graphic, photocopying, recording, taping or other information retrieval systems) without the prior writtenpermission of the copyright holder. Wärtsilä Corporation makes no representation, warranty (express or implied)in this publication and assumes no responsibility for the correctness, errors or omissions for informationcontained herein. Information in this publication is subject to change without notice.Unless otherwise expressly set forth, no recommendation contained in this document is to be construed asprovided due to a defect in the engine, but merely as an improvement of the engine and/or the maintenanceprocedures relating thereto. Any actions by the owner/operator as a result of the recommendations are not

    covered under any warranty provided by Wärtsilä and such actions will thus be at the owners/operators owncost and expense.NO LIABILITY WHETHER DIRECT, INDIRECT, SPECIAL, INCIDENTAL OR CONSEQUENTIAL, IS ASSUMED WITH RESPECT TO THE INFORMATION CONTAINED HEREIN. THIS PUBLICATION ISCONFIDENTIAL AND INTENDED FOR INFORMATION PURPOSES ONLY.

    http://www.wartsila.com/mailto:[email protected]:[email protected]:[email protected]:[email protected]:[email protected]:[email protected]://www.wartsila.com/

  • 8/20/2019 RT-124 Troubleshooting %26 Maintenance on Injection Control Unit

    18/21

     

    to RT-124 APPENDIX 1

    Issue 1, Page 1 / 3

     Alarms

     Any of the following alarms can appear for several seconds during engine start,

    in particular after maintenance work on the fuel injection equipment or on the

    hydraulic oil system. The following troubleshooting guidelines should only be

    considered if these alarms persist.

     Alarms and troubleshoot ing guidelines

    Item Possible alarm Possible cause Remedy / Cause

     A

    ME InjectionQuantity Sensor# meas. Fail

    The alarm is released if themeasured value from thesensor is lower than 2 mA orhigher than 22 mA. This

    means that the signal is out ofrange (4–20 mA) and thishappens with a broken wire ordisconnected sensor.

    Check feedback of quantitysensor. Check plug for tight fit.Make sure measuring sleeveis properly mounted on fuel

    quantity piston.Check cabling between E95box and injection quantitysensor.Replace sensor or disconnectplug temporarily, if feedback isinstable and no sparesavailable.Check the mechanicalassembly of the sensor, seeCountermeasure 1.For sensor replacement seeCountermeasure 2.

    B

    ME Inj. Rail Valve#.# On TimeInjection High

    The time from the rail valveactivation until the rail valvecore physically moves iscalled “ON Time”. IndividualOn Time value is compared tothe average value for all railvalves on the engine. If theindividual On Time becomesgreater than 170% of theaverage, this alarm isreleased.

    Check the cabling betweenthe E95 box and the rail valve.Swap the rail valve with theneighbouring unit, if theproblem moves along with therail valve replace it with a newone.If NOT, replace the upperthree cables of the rail valvesand replace the sockets onthe corresponding FCM at theposition X11, X13 and X14.In cold condition the increasedviscosity of the control oil cancause high On Time.Make sure that the steamtracing of the rail unit is openin case of HFO operation.For rail valve replacement seeCountermeasure 3.

     

  • 8/20/2019 RT-124 Troubleshooting %26 Maintenance on Injection Control Unit

    19/21

     

    to RT-124 APPENDIX 1

    Issue 1, Page 2 / 3

    Table continued...

    Item Possible alarm Possible cause Remedy / Cause

    C

    ME Inj. Rail Valve

    #.# On TimeReturn High

    The time from the rail valve

    activation until the rail valvecore physically moves iscalled “ON Time”. IndividualOn Time value is compared tothe average value for all railvalves on the engine. If theindividual On Time becomesgreater than 170% of theaverage, this alarm isreleased.

    Check the cabling between

    the E95 box and the rail valve.Swap the rail valve with theneighbouring unit, if theproblem moves along with therail valve replace it with a newone.If NOT, replace the lowerthree cables of the rail valvesand replace the sockets onthe corresponding FCM at theposition X11, X13 and X14.In cold condition the increasedviscosity of the control oil can

    cause high On Time.Make sure that the steamtracing of the rail unit is openin case of HFO operation.For rail valve replacement seeCountermeasure 3.

    D

    ME Inj. Time TooShort

    The Injection Time ismeasured from the injectcommand until the returncommand. Individual InjectionTime is compared with theaverage value for the engine.If the individual Injection Timebecomes less than 60% of theaverage this alarm isreleased.

    Could be the consequence ofa rail valve failure.Might be too low openingpressure of injector.Cracked atomizer?Injector pipe leakage?This alarm may occur underrough sea conditions or quickload changes.

    E

    ME Inj. Time TooLong

    The Injection Time ismeasured from the injectcommand until the returncommand. Individual InjectionTime is compared with theaverage value for the engine.If the individual Injection Timebecomes greater than 150%of the average this alarm is

    released.

    Injectors obstructed or withtoo high opening pressure.Possible rail valve failure.Injection through 2 or 1injector only.This alarm may occur underrough sea conditions or quickload changes.

    F

    ME Injectiontiming fail.cylinder #

    Injection timing fail alarm is aconsequence of one of theabove items:D or E.

    Follow items D or E.

    G

    ME Inj. QuantityPiston,Late / No Return

    This alarm appears if the fuelquantity piston does not fullyreturn after the injection. If thesignal from the quantitysensor does not fall below

    5.5 mA after the return

    command it means that the

    fuel quantity piston has notreturned fully. The alarm isdelayed for 30 seconds.

    This can happen if the fuelviscosity is very high (cold fuelor steam tracing on the fuelrail is not working).Rough sea conditions withquick load changes can causethis alarm.Check the mechanicalassembly of the sensor, seeCountermeasure 1.For sensor replacement seeCountermeasure 2.

  • 8/20/2019 RT-124 Troubleshooting %26 Maintenance on Injection Control Unit

    20/21

     

    to RT-124 APPENDIX 1

    Issue 1, Page 3 / 3

    Table continued...

    Item Possible alarm Possible cause Remedy / Cause

    H

    ME Inj. Quantity

    Piston,No Movement(slowdown)

    This alarm appears if the fuel

    quantity piston moved lessthan 4% during the fuelinjection event. The alarm issuppressed for 3 revolutions.

    In case of very low load the

    amount of fuel injected is verylittle and this alarm is normal.Possible rail valve failure.High viscosity fuel.Sticking fuel quantity piston.Rough sea conditions.Check the mechanicalassembly of the sensor, seeCountermeasure 1.For sensor replacement seeCountermeasure 2.

    I

    ME Inj. QuantityPiston, Stuck InMax. Pos.(Inj.cut-off+SLD)

    This alarm appears if thesignal from the sensor ishigher than 18 mA. It meansthat the fuel quantity piston just performed a full strokeand did not return.

    This can happen if the returncommand was not performedfor some reason.It can be due to rail valvefailure (if the rail valve stays ininject position).It can happen if the ICV isstuck in open position.Control oil return pipe isrestricted or closed.High fuel viscosity.Leaking injectors or pipes.Check the mechanicalassembly of the sensor, seeCountermeasure 1.For sensor replacement seeCountermeasure 2.If this alarm appears atstandstill, follow the procedurein Countermeasure 4.

    JME Injectionquantity pistonfail. cylinder #

    This is a consequence of oneof the items:G, H or I.

    Follow items G, H or I.

    Table 1

    Note:The countermeasures are described in the Technical Bulletin RT-124, Issue 1,

    dated 03.04.2012, Chapter “Countermeasures”.

    © 2012 Wärtsilä Switzerland Ltd. – All rights reservedNo part of this publication may be reproduced or copied in any form or by any means (electronic, mechanical,graphic, photocopying, recording, taping or other information retrieval systems) without the prior writtenpermission of the copyright holder. Wärtsilä Corporation makes no representation, warranty (express or implied)in this publication and assumes no responsibility for the correctness, errors or omissions for informationcontained herein. Information in this publication is subject to change without notice.Unless otherwise expressly set forth, no recommendation contained in this document is to be construed asprovided due to a defect in the engine, but merely as an improvement of the engine and/or the maintenanceprocedures relating thereto. Any actions by the owner/operator as a result of the recommendations are not

    covered under any warranty provided by Wärtsilä and such actions will thus be at the owners/operators owncost and expense.NO LIABILITY WHETHER DIRECT, INDIRECT, SPECIAL, INCIDENTAL OR CONSEQUENTIAL, IS ASSUMED WITH RESPECT TO THE INFORMATION CONTAINED HEREIN. THIS PUBLICATION ISCONFIDENTIAL AND INTENDED FOR INFORMATION PURPOSES ONLY.

  • 8/20/2019 RT-124 Troubleshooting %26 Maintenance on Injection Control Unit

    21/21

    Wärtsilä Switzerland Ltd.

    RT-flex 

    Drawn:

    Verif :

    Packing InstructionsICU

    Group

    5564

     

    Proposed corrosion protective product  Dewatering with corrosion protectionWaxy, dry protective film

    Name of product: Dewatering Fluid WA  Article No: Specification No: Substitute for Spec. No: 

    General and physical properties:

    Oil-based corrosion preventiveProtection against:

    Humidity, perspiration, shower-proof 

     Application Temperature:  15°C to 35°C  Application-method

    Thinner%

    Viscosity Sprayingpressure

    Nozzlemm

    k / Ohm

      Humidity:  Brush Yes

    Colour:  like Vaseline Roller Yes

    Degree of gloss:  mat Dipping Yes

    Covering power:  Spraying:low press.

    Yes

    Density:  810 kg/m at 15°C high press. Yes

    Content of solids:  15.5 %  Airless Yes

    Viscosity:  Electro-

    static

    Yes

    Danger class:  A-II Drying: Air

    dust-free

    set to touch completelydry

    Recoatable after:spraying brushing

    Poison class:  free BAG T Nr. 611 500 20° 1 h no no

    Flash point:  40°C in closed pot Oven Time no  Temperature of component:

    Identification duty: ADR/SDR Cl. 3 Pt. 31 c Forced Time no  Temperature of component: 

    Shelf life:  12 months cool/dry Technical data:

    Mixing ratio: 1)  2)  Cross-cut testDIN 53151

    With hardener:  Hardness acc. to:

    Pot life:  Steel ball jet:DIN 53154

    Coverage:  180 m /l Mandrel bend test:DIN 53152

    with dry film thickness of 0.8  microns 3) Ericcson cupping index IE:DIN 53156

    Temperature range: - 20°C to + 60°C Salt-spray test:DIN 50021

    DIN 50’907 150 hrs

    Dry film melting-point: Kesternich test:DIN 50018

    1) Weight 2) Volume 3) On smooth surface Condensed water climate: ASTM-D-148, DIN 51359

    DIN 51’359 150 hrs

    Surface preparation:  Grease-free surface. May be applied to moist surface.

    Features:  Highly water displacing, undercreeps liquidfilms on metal surfaces, displaces liquids and moisture out of pocket holes

    Duration of protection: Indoor storage 9 - 12 months / shed storage 4 - 8 months

    Removal, cleaning:  Normally not necessary. Considered as coat structure for further preservation.Removal with white spirit or petroleum.

    Supplier:  Valvoline Oil Co. Ltd., Div. of Ashland Switzerland, Riedstrasse 11, CH-8317 Tagelswangen,Switzerland Tel. +41 (0) 52 355 3000

    The data given are mean values based on practical experience. Application according to the supplier’s specifica-tion and at the user’s risk with regard to climatic and specific conditions.

     APPENDIX 2