rugged, series mechlevel... · 2009-09-24 · glycol dehydration involves putting glycol in...

20

Upload: others

Post on 21-Apr-2020

5 views

Category:

Documents


0 download

TRANSCRIPT

rugged, reliable

problem solvers

1520

1530

1550

1510

The SOR® family of 1500 series mechanical level switches answerindustry’s call for less expensivealternatives to the traditional chambered switch.

The 1510 Horizontal-mount, float-operated, electric level switch.

The 1540 Horizontal-mount, non-bleed, pneumatic level switch.

The 1530 Horizontal-mount, float-operated, pneumatic level switch.

The 1550 Vertical-mount, float-operated, electric level switch.

The 1520 Vertical-mount, vane-operated electric flow switch.

The 1500s are suitable for most any point level application.• separators • wetscrubbers• suctionscrubbers • sealpots• dehydrators •make-upwater• refrigeration • vaporrecovery• re-injection • overflowprotection• smalldiametervessels • lubeoilreservoirs• high-lowalarm • pumpon-pumpoff• coolingwater • contaminatedwater applications applications

Common 1500 series features and benefits:• allstainlesssteelconstruction• standardproductratingof1500psi@-40to400ºF 100BAR@(-40to204˚C)• minimumworkingtemperatureratingof-40˚F• completeisolationoftheprocessfromthe switch–noo-ringsorseals• horizontalswitchesmaybeorientedforhigh-or low-levelaction-whystock2differentswitches?• ohyeah...lowprice

dependable under demanding conditions

1540

1SOR® 1500 Series Mechanical Level Switches

Application: Separators Multipleseparatorsareacommonsightinthenaturalgasindustry.Evenwithrawgaswells,thereisalwayscondensate, water, or some other NGL that needs to be separatedpriortotransportingitforprocessing. Thereareanumberofseparationtechnologiesandall of them require collection of these liquids after separation.Somearesimplegravityseparators,somecan be quite elaborate. Regardless of the separation method, SOR 1500s fit the application.

SOR 1500 series mechanical level switches and a generic, horizontal separator process.

Inlet separatorAsrawgasfromthefieldenterslargevesselsintheplantcalled“inletseparators,”condensate(naturalgasoline)andwaterisremovedfromthemaingasstream.AnSOR1510levelswitchismountedinaseparator at, or about, the same elevation as the inlet pipethatbringsincombinationsoffluidssuchasoil,water,gasandcondensate.Ashut-offvalveisinstalledintheinletpipingthatisusuallykeptopenbyairpressure and allows the fluid mix to enter the vessel. Whenliquidreachesthefloatonthe1510,theswitch actuates. Uponactuation,asignalissentto(forexample)asolenoidvalve(sometimesviaaPLC)thatblockstheairnormallyroutedtothevalve.Withtheairsupplycut off, the valve closes and fluid flow to the separator comes to a halt. WhenanSOR1540isused,theairsupplyreachesthe shut-off valve via the pneumatic level switch. When actuated,theairisblockedandtheshut-offvalveclosesbecauseofalackofairsupply. Inbothcases,aseparatelevelcontrollerworksincon-junctionwithadumpvalvethatdrainstheliquidfromthe separator.

field-provenSOR 1500 series level switches

have conquered the test of time

under some of the toughest

operating conditions – the oil

patch. Designed for harsh and

hazardous environments and

process materials where tough

welds and rugged components

are critical, the 1500s are built

to take it.

simple, reliable solutions

2 SOR® 1500 Series Mechanical Level Switches

Blow case separator Anotherspecificseparatorapplicationwhere1500serieslevelswitchesexceliscontrollingablowcaseseparatorupstream from a compressor. Ablowcaseseparatorisessentiallytwovesselsconnectedvertically.Gasflowsintotheuppervessel(compressor)andgravitypullsliquidsdownintothelowervessel(blowcase).Whentheblowcaseisfull,a1500seriesswitchtripsandclosesavalvebetweenthetwotanks.Asecondvalveopensandallowsthecompressedgasfromabovebackdownintotheblowcase. This forces the accumulated liquids out into the pipeline – downstream from the compressor. Asecond1500seriesswitchisoftenusedasalowleveltoresetthesystemwhentheblowcaseempties.Boththe1510and1540maybeusedwithequaleffec-tiveness;theoneyouchoosedependsonlyontheapplicationandyourpreference.

The 1500s are not restricted to collection tanks. They may also be used to control the level of sour applications and/or “sweetening solutions” with NACE certification.

Glycol dehydratorOften,aglycoldehydratorisnecessaryforremovaloftinywaterdropletsfromnaturalgasifthewaterwasnotcompletelyextractedwiththeseparator.Theprocessinvolves“dehydrating”thenaturalgasandusuallycallsforoneoftwoprocesses:absorption or adsorption.The1500seriesswitchesfallintotheabsorption process. Glycoldehydrationinvolvesputtingglycolincon-tactwithastreamofnaturalgasthatcontainswater.Theglycolabsorbsthewaterfromthewetgasstream,becomesheavierandsinkstothebottomofthecontactorwhereitisexpelled.Thenaturalgasistheneasilyroutedoutofthedehydratorandtheglycol/watersolutionissenttoaspecialboilerthatsteamsawaythewaterallowingtheglycoltoberecycled. AnSOR1500seriesmechanicallevelswitchisinstalledontheinletscrubber/contactor/absorbertomonitorglycol/waterlevels.Whenmountedbelowthewetgasinlet,itpreventstheglycol/waterlevelfrom

risingaboveit.Ifthelevelreachestheswitch,asignalissenttoasolenoidthatworksinconjunctionwith a dump valve which drains the liquid from the scrubber/contactor/absorber.

Flash tank separator-condenserWhenabsorbingwaterfromthewetgasstream,theglycolsolutionwillsometimespickupsmallamountsofmethaneandothercompounds.Flashtankseparatorsdecreasethelossesofthesematerialsbeforetheglycolsolutionreachestheboiler.Theprocessvirtuallyeliminatestheburningandsubsequentventingofthesecloselymonitoredcompounds.SOR1500seriesswitchesareapopularchoicetomonitorflashtanklevelsandtopreventthemfromreachingacriticalpoint.

keep intricate processes running smoothly

3SOR® 1500 Series Mechanical Level Switches

Ahorizontallymounted,float-operatedlevelswitchsuitableforplantandOEMapplicationswhereopenorclosedcontactsarerequiredtosignalpresenceorabsenceofliquidatadiscretelevel.Thefloatextensionarmmovesamagnetwhichactuatesorde-actuatesahermeticallysealedreedswitch.Actuation/de-actuationmaybereversedbyrotatingtheunit180degrees.

SpecificationsMounting (half coupling only) Orientation Horizontalmountonly Connectionsize 1-1/2”NPT(M)Standard

Maximum Process Pressure 1500psi(100BAR)

Electrical Switchtype Hermeticallysealed reedswitchwith18” 20AWGwireleads Switchrating(resistive) 1ampat110VAC 3ampsat28VDC Relayhousing ClassI,GroupA,B,C&D; Division1&2 Connectionsize 1/2”NPT(F) Contactform SPSTMinimum Specific Gravity 0.45

Design Code ANSIB31.3

Shipping Weight Approximately6lbs.(3kg)

Agency Listing CSACertified,ATEXand IECEXapproved–see OptionalAccessorieson page5,GOST-R

Options

For Change To 2”NPT(M) G5A G2A Flangedmounting G5A SeeOptionalFlanges atrightfordesignator (316SSonly) SPDT W9 W1

1510 electric level switch

Optional Flanges (316SS construction only)

Designator Raised Face Flange

G7C 2.5inches 150#

G7D 2.5inches 300#

G7E 2.5inches 600#

G3C 3inches 150#

G3D 3inches 300#

G3E 3inches 600#

G4C 4inches 150#

G4D 4inches 300#

G6C 6inches 150#

G6D 6inches 300#

Floats are detached from flanged units for shipping.

SOR® 1500 Series Mechanical Level Switches

NOTE: Actuate/deactuate points vary. Operates satisfactorily in 2-inch full coupling (2.22 ID).

4

Drawing 0390027

mminches

Optional Accessories Addoptiondesignator(s)toendofmodelnumber.

Designator Description BB Wettedpartsarecleanedforindustrialoxygenservice. CL* ATEXandIECEXapproved.

CR 3/4”NPT(F)conduitconnection.

CS* CSACertifed.ClassI,GroupA,B,C,D;Division1&2. Forrelayoption;ClassI,GroupC&D,Division1&2.

CV CanadianRegistrationNumber(CRN).Maximumallowablepressureratingis1500psi. Consultthefactoryforhigherpressuresandadditionalinformation.

CZ ANSIB31.3certificateofconformance.

MC** Manualcheckaccessory(usesVitonGLTo-rings).

NC NACEconstruction-MR-01-75.Availableonlywith316SSmaterialsofconstruction.

PP Tag,fiber.Attachedwithplasticwiretohousing. Stampedwithcustomer-specifiedtagginginformation.

RB 24VDCpoweredDPDTrelayinexplosionproofterminalbox. Contactrating:[email protected],GroupC,D;Division1&2.

RC 120VACpoweredDPDTrelayinexplosionproofterminalbox. Contactrating:[email protected],GroupC,D;Division1&2.

RR Tag,stainlesssteel.Attachedwithstainlesssteelwiretohousing. Stampedwithcustomer-specifiedtagginginformation–2lines,18characters perlineincludingspaces.

TT Stainlesssteelnameplatepermanentlyattachedtohousing. Stampedwithcustomerspecifiedtagginginformation.

VV Fungicidalvarnish.Coversexteriorexceptworkingparts.

YY Epoxycoating.Exterioronly.Polyamideepoxywith316SSpigment.

*CSorCLoptionisrequiredonallflange-mountedunits.**ManufacturerlimitsonVitonGLTare-40to400°F.

How to OrderSelectmodelnumberfromthetablebelow.Accessorydesignator(s)maybeaddedafterES,ifrequired.(SeeOptionalAccessoriesabove.)

Model Number Body Material Float Material Process Rating

1510B-G5A-C-W9-ES 303SS*Standard 316SS(Standard) 1500psi -40to400ºF(-40to204˚C) 100BAR

1510B-G5A-M-W9-ES Monel 900psi -40to400ºF(-40to204˚C) 62BAR

1510B-G5A-S-W9-ES Polypropylene 5000psi -40to150ºF(-40to65.5˚C) 345BAR

1510C-G5A-C-W9-ES 316SS 316SS 1500psi -40to400ºF(-40to204˚C) 100BAR

1510C-G5A-M-W9-ES Monel 900psi -40to400ºF(-40to204˚C) 62BAR

1510C-G5A-S-W9-ES Polypropylene 5000psi -40to150ºF(-40to65.5˚C)345BAR

*AlsoknownasASTMA582.

SOR® 1500 Series Mechanical Level Switches 5

Ahorizontallymounted,float-operatedlevelswitchsuitableforplantandOEMapplicationswherepneumaticvalveoperationisrequiredtosignalpresenceorabsenceofliquidatadiscretelevel.Thefloatarmmovesamagnetthat,inturn,movesashuttlethateitherblocksorallowspilotpressuretopassandoper-ateancillaryequipment.Actuationorde-actuationmaybereversedbyrotatingtheunit180degreesorbyswitchinginletconnections.

Specifications Orientation Horizontalmountonly Connectionsize 2”NPT(M) I/Oconnection 1/4”NPT(F) Outputpressure 0-30psi(0-2BAR) Pilot(supply)pressure 0-30psi(0-2BAR) Flowrate@30psisupply 60SCFH(.01CMH) Leakrate 0.5SCFH(.01CMH) Maximumprocesspressure 1500psi(100BAR) Minimumspecificgravity 0.65 Shippingweight 3.5lbs.(2kg)

1540 side-mount pneumatic level switch

*Actuate/deactuate points vary. Operates satisfactorily in 2-inch full coupling (2.22 ID).

6 SOR® 1500 Series Mechanical Level Switches

SCFH–StandardCubicFeetperHour

CMH–CubicMetersperHour

Thesupplymediamustbefilteredandoilfree.Airistheusual

medium,howeveranydry,filteredgasmaybeused.

Drawing 0091392

mminches

Optional Accessories Addoptiondesignator(s)toendofmodelnumber.

Designator Description

BB Wettedpartsarecleanedforindustrialoxygenservice.

CV CanadianRegistrationNumber(CRN).

CZ ANSIB31.3certificateofperformance.

NC NACEconstruction–MR-01-75.

PP Tagfiber.Attachedwithplasticwiretohousing. Stampedwithcustomer-specifiedtagginginformation.

RR Stainlesssteelnameplateattachedtohousingwithwire. Stampedwithcustomer-specifiedtagginginformation–2lines, 18charactersperlineincludingspaces.

TT Stainlesssteelnameplatepermanentlyattachedtohousing. Stampedwithcustomer-specifiedtagginginformation.

VV Fungicidalvarnish.Coversexteriorexceptworkingparts.

YY Epoxycoatingonexterioronly.Polyamideepoxywith316SSpigment.

How to OrderSelectmodelnumberfromthetablebelow.Accessorydesignator(s)maybeaddedafterPS,ifrequired(seeOptionalAccessoriesabove).

Model Number Body Material Float Material Process Rating

1540C-G2A-C-J0-PS 316SS 316SS *-40to400˚F1500psi (-40to204˚C) (100BAR)

*ManufacturerlimitsonVitonGLTare-40to400°F.

7SOR® 1500 Series Mechanical Level Switches

Ahorizontallymounted,float-operatedlevelswitchsuitableforplantandOEMapplicationswherepneumaticvalveoperationisrequiredtosignalpresenceorabsenceofliquidatadiscretelevel.Thefloatextensionarmmovesamagnetthatactuatesorde-actuatesapilotvalvetooperateapneumaticampli-fier.Actuation/de-actuationmaybereversedbyrotatingtheunit180degrees.

SpecificationsMounting

Orientation Horizontalmountonly Connectionsize 1-1/2”NPT(M)Standard

For Change To

Flangedmounting G2A SeeOptionalFlangesat rightforoptiondesignator.

Maximum process pressure 1500psi(100BAR)

Supply pressure range 20to60psi (1.4to4.1BAR)

Supply pressure connection size 1/8”NPT(F)

Minimum specific gravity 0.60

Design Code ANSIB31.3

Shipping Weight Approximately6lbs.(3kg)

Ifsupplypressuremediumisnaturalgas,afilter/regulator

issuggestedonthesupplylineandthevalveventportshould

be piped to a safe area.

1530 pneumatic level switch

Optional Flanges (316SS construction only)

Designator Raised Face Flange

G7C 2.5inches 150#

G7D 2.5inches 300#

G7E 2.5inches 600#

G3C 3inches 150#

G3D 3inches 300#

G3E 3inches 600#

G4C 4inches 150#

G4D 4inches 300#

G6C 6inches 150#

G6D 6inches 300#

Floats are detached from flanged units for shipping.

*Actuate/deactuate points vary. Operates satisfactorily in 2-inch full coupling (2.22 ID).

8 SOR® 1500 Series Mechanical Level Switches

Drawing 0390026

mminches

Optional Accessories Addoptiondesignator(s)toendofmodelnumber.

Designator Description

BB Wettedpartsarecleanedforindustrialoxygenservice.

CV CanadianRegistrationNumber(CRN)–maximumallowable pressureratingis1500psi.Consultthefactoryforhigherpressuresandadditionalinformation.

CZ ANSIB31.3certificateofperformance.

NC NACEconstruction–MR-01-75.Availableonlywith316SSmaterialsofconstruction.

PP Tag,fiber.Attachedwithplasticwiretohousing.Stampedwithcustomer-specified tagginginformation.

RR Stainlesssteelnameplateattachedtohousingwithwire.Stampedwith customer-specifiedtagginginformation–2lines,18charactersperlineincludingspaces.

TT Stainlesssteelnameplatepermanentlyattachedtohousing. Stampedwithcustomer-specifiedtagginginformation.

VV Fungicidalvarnish.Coversexteriorandinteriorexceptworkingparts.

YY Epoxycoating.Exterioronly.Polyamideepoxywith316SSpigment.

How to OrderSelectmodelnumberfromthetablebelow.Accessorydesignator(s)maybeaddedafterPS,ifrequired(seeOptionalAccessoriesabove).

Model Number Body Material Float Material Process Rating

1530B-G2A-C-J0-PS 303SS*Standard 316SS 1500psi -40to400˚F(-40to204˚C) 100BAR

1530B-G2A-M-J0-PS 303SS* Monel 900psi -40to400˚F(-40to204˚C) 62BAR

1530B-G2A-S-J0-PS 303SS* Polypropylene 5000psi -40to150˚F(-40to204˚C) 345BAR

1530C-G2A-C-J0-PS 316SS 316SS 1500psi -40to400˚F(-40to204˚C) 100BAR

1530C-G2A-M-J0-PS 316SS Monel 900psi -40to400˚F(-40to204˚C) 62BAR

1530C-G2A-S-J0-PS 316SS Polypropylene 5000psi -40to150˚F(-40to204˚C) 345BAR

NOTE:Maximumtemperatureforpolypropyleneis150˚F.*AlsoknownasASTMA582.

9SOR® 1500 Series Mechanical Level Switches

Averticallymountedfloat-operatedlevelswitchsuitableforplantandOEMapplicationswhereopenorclosedcontactsarerequiredtosignalpresenceorabsenceofliquidatadiscretelevel.Thefloatstemmovesamagnetthatactuatesorde-actuatesahermeticallysealedreedswitch.

SpecificationsMounting (half coupling only)

Orientation Verticalmountonly Connectionsize 1-1/2”NPT(M)Standard

For Change To 2”NPT(M) F5A F5A Flangedmounting F5A SeeOptionalFlangesat rightfordesignator–316SS constructiononly

Maximum process pressure 443psi(30.5BAR) @100˚F(38˚C

Process temperature range -40to400˚F(-40to204˚C)

NOTE: Housing is not submersible in processes above 320˚ F (160˚ C).

Electrical Switchtype Hermeticallysealed reedswitchwith18” 20AWGwireleads Switchrating(resistive) 1ampat110VAC 3ampsat28VDC Housing ClassI,GroupsC&D; Divisions1&2 Relayhousing ClassI,GroupsC&D; Divisions1&2 Connectionsize 1/2”NPT(F) Contactform SPST–forSPDTchange W9toW1inmodelnumber

Minimum specific gravity 0.60basedon16”insertion insertion depth L – see drawingatright

Minimum insertion depth L 5”(13cm) Fullcoupling 7”(17.8cm) Halfcoupling 5.25”(13.3cm)

Maximum insertion depth L 48”(122cm)

Minimum specific gravity@ 48” (122 cm) 0.69

Design Code ANSIB31.3

Shipping Weight Approximately5lbs.(2.2kg)

Agency Listing CSACertified,Class1, GroupsA,B,C,D; Divisons1&2–forrelay option:Class1,Groups C&D;Divisions1&2; ATEXandIECEXapproved, GOST-R

1550 vertical electric level switch

Optional Flanges316SS construction only. All flanges are seal-welded to bodies.

Designator Raised Face Flange

F7C 2.5inches 150#

F7D 2.5inches 300#

F7E 2.5inches 600#

F3C 3inches 150#

F3D 3inches 300#

F3E 3inches 600#

F4C 4inches 150#

F4D 4inches 300#

F4E 4inches 600#

F6C 6inches 150#

F6D 6inches 300#

F6E 6inches 600#

Floats are detached from flanged units for shipping.

10 SOR® 1500 Series Mechanical Level Switches

Drawing0390428

mminches

Optional Accessories Addoptiondesignator(s)toendofmodelnumber.

Designator Description

BB Wettedpartsarecleanedforindustrialoxygenservice.

CL* ATEXandIECEXapproved.

CR 3/4”NPT(F)conduitconnection.

CS* CSAcertifiedClassI,GroupA.B,C,D,Division1&2 Relayoption–ClassI,GroupC&DDivision1&2

HT Explosion-proofterminalboxCSAcertified. ClassI,GroupA.B,C,D ClassII,GroupE,F,G ClassIII,DivisionI(NEMA4X)

NC NACEconstruction–MR-01-75.Availableonlywith316SSmaterials.

PP Tag,fiber.Attachedwithplasticwiretohousing. Stampedwithcustomerspecifiedtagginginformation.

RB 24VDCpoweredDPDTrelayinexplosion-proofterminalbox. Contactrating:10amps@115VAC ClassI,GroupD;Division1&2.

RC 120VDCpoweredDPDTrelayinexplosion-proofterminalbox. Contactrating:10amps@115VAC ClassI,GroupD;Division1&2.

RR Tag,fiber.Attachedwithstainlesssteelwiretohousing.Stampedwithcustomer-specified tagginginformation–2lines,18charactersperlineincludingspaces.

TT Stainlesssteelnameplatepermanentlyattachedtohousing. Stampedwithcustomer-specifiedtagginginformation.

VV Fungicidalvarnish.Coversexteriorandinteriorexceptworkingparts.

YY Epoxycoating.Exterioronly.Polyamideepoxywith316SSpigment.

*CSorCLoptionisrequiredonallflange-mountedunits.

How to OrderSelectmodelnumberfromthetablebelow.Accessorydesignator(s)maybeaddedafterPS,ifrequired(seeOptionalAccessoriesabove).

Model Number Body Material Float Material Process Rating

1550C-F5A-C-W9-ES 316SS 316SS 443psi (30.5BAR)

1550C-F5A-M-W9-ES 316SS Monel 265psi (18.2BAR)

•CustomertospecifyinsertiondepthLforeachswitch–seedrawingatleft.•StemguidesnotinstalledonuntiswithinsetionsdepthLlessthan7”(177.8mm).•3.5”(90mm)diameterfloatwillnotfitthroughmanyprocessconnections.•Floatmayneedtobeattachedfrominsidethevesselafterinstrumentinstallation.

11SOR® 1500 Series Mechanical Level Switches

Averticallymounted,vane-operatedflowswitchsuitableforplantandOEMapplicationswhereopenorclosedcon-tactsarerequiredtosignalfloworno-flowconditions.Thevaneextensionarmmovesamagnetthatactuatesorde-actuatesahermeticallysealedreedswitch.

SpecificationsMounting

Orientation Verticalmountonly Connectionsize 1-1/2”NPT(M)Standard

For Change To 2”NPT(M) F5A F5A Flangedmounting F5A SeeOptionalFlangesbelow fordesignator–316SS constructiononlyMaximum process pressure 1500psi(100BAR)Process temperature range -40to400˚F(-40to204˚C)Electrical Switchtype Hermeticallysealed reedswitchwith18” 20AWGwireleads Switchrating(resistive) 1ampat110VAC 3ampsat28VDC Housing ClassI,GroupA,B,C,D; Division1&2w/CSoption Opionalrelayhousing ClassI,GroupC,D; Division1&2w/CSoption

Minimum flow rate 1FPS

Design Code ANSIB31.3

Shipping Weight Approximately6lbs.(3kg)

Agency Listing CSACertifiedorATEXandIEC approved(optional)–see OptionalAccessorieson page13,GOST-R

Optional Flanges (316SS construction only) Designator Raised Face Flange

F7C 2.5inches 150#

F7D 2.5inches 300#

F7E 2.5inches 600#

F3C 3inches 150#

F3D 3inches 300#

F3E 3inches 600#

F4C 4inches 150#

F4D 4inches 300#

F4E 4inches 600#

F6C 6inches 150#

F6D 6inches 300#

F6E 6inches 600#

1520 electric flow switch

12 SOR® 1500 Series Mechanical Level Switches

Drawing 0390011

mminches

Optional Accessories Addoptiondesignator(s)toendofmodelnumber.

Designator Description

BB Wettedpartsarecleanedforindustrialoxygenservice.

CL* ATEXandIECEXapproved.ExiaIICT3(-40°C<Ta<+160°C)

CR 3/4”NPT(F)conduitconnection.

CS* CSAcertified.explosionproof,ClassI,GroupC&Dwhenusedwith RBorRCrelayoptionalaccessories. CSAcertifiedexplosionproofClassI,GroupA,B,C,D.

CV CanadianRegistrationNumber(CRN)–processratingsmaybeaffected. Consultthefactoryforpressureratingandadditionalinformation.

HT Explosion-proofterminalboxCSAcertified.

NC NACEconstruction–MR-01-75.Availableonlywith316SSmaterials.

PP Tag,fiber.Attachedwithplasticwiretohousing. Stampedwithcustomerspecifiedtagginginformation.

RB 24VDCpoweredDPDTrelayinexplosion-proofterminalbox.Contactrating:[email protected],GroupC,D;Division1&2.

RC 120VDCpoweredDPDTrelayinexplosion-proofterminalbox. Contactrating:10amps@115VAC,ClassI,GroupC,D;Division1.

RR Tag,stainlesssteel.Attachedwithstainlesssteelwiretohousing. Stampedwithcustomer-specifiedtagginginformation–2lines, 18charactersperlineincludingspaces.

TT Stainlesssteelnameplateorseparatestainlesssteeltag.Permanently attachedtohousing.Stampedwithcustomer-specifiedtagginginformation.

VV Fungicidalvarnish.Coversexteriorandinteriorexceptworkingparts.

YY Epoxycoating.Exterioronly.Polyamideepoxywith316SSpigment.

*CSorCLoptionisrequiredonallflange-mountedunits.

How to OrderAddoptiondesignatorstoendofmodelnumber.

Model Number Body Material Vane Material

1520B-F5A-C-W9-EF 303SS* 316SS(Standard)

1520C-F5A-C-W9-EF 316SS 316SS

*AlsoknownasASTMA582

13SOR® 1500 Series Mechanical Level Switches

Manual CheckAvailable on 1510 electriclevel switch only.

The original 1500 was born from customer input and SOR continues the tradition by offering a manual check option for the 1510 electric level switch.TheoptionalManualCheckallowstheusertoverifyswitchintegritywithoutremovingthe1510fromthevesselorincreasingordecreasingliquidlevels.Thisisparticularlyusefulforsystemstestinginsafetyapplications,suchasamanualoverride,wheretheswitchisnotcalleduponveryoften.Itmayalsobeusedasamethodtomanuallytriggera valve or activate the normal function the switch. Manycustomersaremandatedbyregulatoryauthoritiestoincludethistypeoffunction.OthersjustliketheaddedfunctionalityandpeaceofmindtheManualCheckprovides.

The1510ManualCheckoptionisactivatedbyturningtheknoblocatedonthesideoftheswitchbody.When the “N” or neutral indicator is oriented towards thepermanently-stampedguidemarker,theunitisinnormaloperatingmode.Turningtheknobclockwiseorcounterclockwise(dependingonwhethertheswitchisperformingahigh-orlow-levelfunction)manuallymovesthefloatandchangestheswitchstate.NOTE:alwaysre-turntheknobtotheneutralpositionbeforeleavingtheswitch. Whateveryourapplication,theManualCheckoptionprovidesaddedfunctionalitytotheSOR1510withoutcompromisingpressureortemperatureratings.

ChambersAvailable for all 1500 serieslevel switches.

Customers often ask SOR to use its machining and welding expertise to make small chambers that go with the 1500s they purchase. Thanks to a major expansion of the SOR manufacturing facilities, we now offer competitively priced, ANSI quality chambers for use with the 1500 series products. Flexibleprocessesmakeitpossibleforustoofferchambersforboth1-1/2and2-inchbody1500seriesproducts,aswellasawiderangeofavailableprocessconnections.Whetheryourequirethestandard1-inchNPTorevenflangedconnections,SORcanmakeithappen.Justgiveusyourrequirementsandwe’reoffandrunning. WithchambersfromSORyoucanconsolidatevendorsandbuyfromanameyouhavetrustedformanyyears.

popular add-ons

14 SOR® 1500 Series Mechanical Level Switches

Contact your local SOR representative for more information about SOR chambersand Manual Check.

Replacement PartsSORmanufacturesandmaintainsasupplyofreplacementpartsforits1500serieslevelswitches.

Part Number Description

1510 3130-091.........SPSTHermeticallySealedReedSwitchCapsule 3130-242.........SPDTHermeticallySealedReedSwitchCapsule 3130-106.........SPSTHermeticallySealedReedSwitchCapsuleforCSACertifiedunits 3130-243.........SPDTHermeticallySealedReedSwitchCapsuleforCSACertifiedunits 3130-052.........316SSFloatAssembly

1540 9227011.........Pneumaticsensorassembly 3100152 .........Float 9227012 .........Floatandarmassembly

1530 3130-114......... Pneumaticrelayassembly 3130-052.........316SSFloatassembly

1550 3130-091.........SPSTHermeticallysealedreedswitchcapsule 3130-242.........SPSTHermeticallysealedreedswitchcapsule 3130-106.........SPSTHermeticallysealedreedswitchcapsuleforCSAcertifiedunits 3130-243.........SPDTHermeticallysealedreedswitchcapsuleforCSAcertifiedunits 3101-132.........316SSFloat(consultthefactoryforothermaterials) 3130-396.........Actuatorreplacementkit

1520 3130-091.........SPSTHermeticallySealedReedSwitchCapsule 3130-242.........SPDTHermeticallySealedReedSwitchCapsule 3130-106.........SPSTHermeticallySealedReedSwitchCapsuleforCSACertifiedunits 3130-243.........SPDTHermeticallySealedReedSwitchCapsule 3130-118.........316SSVaneAssembly 3130-403.........ActuatorArmReplacementKit(1-1/2”NPTandflangedprocessconnections) 3130-404.........ActuatorArmReplacementKit(2”NPTprocessconnection)

All 1500 series mechanical level switches come with a 5 year warranty

SORagreestorepairorreplaceanyswitchfoundtobedefectiveinmaterialorworkmanshipwithinfive yearsfromdateofshipment.Thelimitedwarrantyisvalidonlyiftheswitchwasinstalledinaccordance withpublishedfactoryinstallationinstructions,operatedwithinthedesignlimitationsstatedonthenameplate andreturnedtothefactoryforinspection,freightprepaid,withinthewarrantyperiod.Contactthefactory forreturnauthorization.Noclaimforlabororconsequentialdamageswillbeallowed.

NOTE: Designs and specifications are subject to change without notice. For latest revisions see www.sorinc.com.

15SOR® 1500 Series Mechanical Level Switches

custom engineered to fit your application

16 SOR® 1500 Series Mechanical Level Switches

rugged, reliable

problem solvers

SOR has a registered quality system to ISO 9001:2000. World headquarters are located in Lenexa, Kansas USA with satellite offices in the United Kingdom and China.

SOR supports its markets with more than 120 sales representatives worldwide. To find a representative near you, please visit www.sorinc.com.

SOR Inc.

14685West105th Street

Lenexa,Kansas66215

Phone913-888-2630

TollFree800-676-6794

Fax913-888-0767

www.sorinc.com

www.echOsonix.com

Registered Quality System to ISO 9001:2000 Form 1378 (02.09) ©2009 SOR Inc.

Process Instrumentation

TemperatureSwitches

Pre

ssu

re

Flow

Tem

pera

ture

Level

echOsonix® Level Transmitters

LevelSwitches

Flow Switches

PressureSwitches

SOR® offers a full line of commercial-grade process instruments.

We Deliver Quality On Time

SOR Europe, Ltd.

FarrenCourt

Cowfold

WestSussexRH138BP

UnitedKingdom

Phone44(0)1403864000

Fax44(0)1403864040

[email protected]

SOR China

Room903,No.10Building

WanDaPlaza

RNo.93JianGuoRoad

ChaoYangDistrict

Beijing,China100022

Phone+86(10)58208767