RW-UV SeriesSkid-Mounted WaterReclamation SystemsWater Control RW-UV Series Water Reclamation Systems provide an innovative option for drastically reducing building water and sewer usage, gaining multiple points towards LEED® certification, and minimizing the negative environmental impact of new and existing commercial facilities. These systems harvest and store water from building storm drainage systems (as well as other select sources such as condensate and filter backwash) – and then reuse it to provide clean, nearly potable quality water to irrigation systems, toilets, urinals, cooling towers, refrigeration equipment, and other non-potable fixtures. With over 35 years of experience in commercial water filtration and conditioning, Water Control is a name you can count on for innovative, high quality solutions to your "green" system challenges.

System Advantages:· May contribute toward multiple points under LEED® v4 program:

- “Integrative Process” (1 point)- “Outdoor Water Use Reduction” (Pre-requisite + 1-2 points)- “Indoor Water Use Reduction” (Pre-requisite + 2 – 7 points)- “Cooling Tower Water Use” (1 – 2 points)- “Rainwater Management” (1 – 3 points)- “Regional Priority” (up to 4 points)

· Greatly reduces water and sewer usage: Reduced impact fees!· NO Chemicals or additives required· Minimal system maintenance requirements· Guaranteed minimum disinfection levels· The only system able to maintain a clean cistern environment!· BMS-compatible – Call for details.

ModelMaxFlow

(gpm)*

Estimated Bulb Life (hours)

Filtration Tank Circulation Flow Rate (gpm)

Maximum Cistern Size

(gal)

Pressure Tank Size

RW-UV-10 10 10,000 Cartridge 10 4,000 35 gal.

RW-UV-40 40 10,000 1Cartridge,1 Bag 40 12,000 50 gal.

RW-UV-80 80 10,000 2 X Bag 80 24,000 85 gal.

RW-UV-120 120 10,000 2 X Bag 120 32,000 120 gal.

RW-UV-160 160 10,000 4 X Bag 160 41,000 120 gal.

RW-UV-200 200 10,000 4 X Bag 200 50,000 120 gal.

RW-UV-240 240 10,000 4 X Bag 240 60,000 120 gal.

*System output flow rate @ minimum 40 psi – consider any additional pressure loss that may occur in the plumbing system.

Page 3: RW-UV Series Water Reclamation Systems Engineer Guide

3

RW-UV Series Details:

RW-UV SERIES UNITS Turnkey water reuse systems, which arrive pre-plumbed and pre-wired for easy installation and operation. A powerful UV germicidal lamp system deactivates and destroys microorganisms and pathogens. The onboard purification process provides filtered, sanitized, reclaimed water on-demand. No post holding tank or sump pump is required. The system’s small footprint takes only minimal space in the mechanical room.

ULTRAVIOLET GERMACIDAL LAMPS Works seamlessly with on-board filtration and repressurization systems to deliver verifiably sanitized water to fixtures and equipment. When water is required, a powerful on-board pump pulls it from the cistern and directs it through a cartridge filter and/or up to 4 filter bags (depending on system size), and finally through a quantity of 1 to 6 X 254nm UV germicidal lamp(s) designed to specifically match maximum system flow rate parameters. When water is no longer required by fixtures or equipment, an automatic valve diverts the flow of water back to the cistern. This continuous recirculation through the filters and UV lamp(s) ensures a clean, sanitized tank environment and can be programmed to shut down during off hours (for energy conservation purposes). If UV light levels become ineffective (due to bulb failure, bio-slime, or water turbidity), an on-board monitor instantly sends the system into fresh (city) water bypass mode and sounds an alarm. Similar fail-safe mechanisms are activated if the filter bags should become plugged (and require replacement) or if tank water levels become too low.

INSTALLATION After the cistern tank is in place, a plumber can typically install the system in two days. An electrician simply connects required power to the unit. Once installed, a simple, one-time factory startup is all it takes to get the system into service.

MAINTENANCE Primarily limited to periodic inspection and cleaning of simple pump baskets, and filter bags (which can be accomplished in a few minutes about once a month), plus the replacement of UV lamp bulbs approximately one time per year.

QUALITY FEATURES Includes a powder-coated aluminum frame, schedule 80 PVC & solid brass plumbing, a heavy-duty pump, stainless steel UV lamp housings & system hardware, advanced electronic controls with BMS compatibility, and much more.

SYSTEM DESIGN AND SUPPORT Water Control's Technical Service Department is here to help. We can provide you with everything from system sizing and layout (AutoCAD™ or Revit™), to system delivery/setup/startup services, LEED® point registration, and troubleshooting. Call or email us today to get started.

Page 4: RW-UV Series Water Reclamation Systems Engineer Guide

4

System SizingWater Control’s Technical Support Department is ready to serve. Our Tech Support Specialists can help you with RW System and cistern sizing, roof drainage and other reclaim source collection design, system CAD™ layouts, permitting, and LEED® point submittals.

To get started, please call or email us with the following information:

· Project name, type of facility, and geographic location

· Reclaimed water source(s) (roof drains, drain tiles, condensate, softener/filter backwash, etc.)

· Intended use for reclaimed water (irrigation, cooling towers, fixture flushing, vehicle wash, industrial process, boiler feed, etc.)

· System peak flow requirements (GPM and pressure)

· Estimated (peak) monthly reclaimed water usage (total gallons)

· Roof area (sq ft) if stormwater is to be reclaimed

Contact Our Technical Support Department:Phone: 1-866-405-1268 • Fax: 763-427-5665Email: [email protected]

Page 5: RW-UV Series Water Reclamation Systems Engineer Guide

5

System Dimension Information*NOTE: Additional space will be required for cistern tank (if located indoors). System designs are the property of Water Control and may not be reproduced without written permission.

System Dimensions: Model RW-UV-10

System Dimensions: Model RW-UV-40

*System dimensions and designs may be subject to change without notice.

RW-UV-40 SPECIFICATIONSFLOW RATE 40 GPM

UV INTENSITY 30mW/cm2 AT RATED FLOW

PUMP 2 HP, 40 GPM @ 50 PSI

SUCTION INLET (PUMP) 1½ INCH FNPT

SYSTEM OUTLET (PUMP) 1½ INCH FNPT

RECIRCULATION OUTLET 1½ INCH FNPT

FRESH WATER INLET 1½ INCH FNPT

BLADDER TANK SIZE 50 GALLONS

RW-UV-10 SPECIFICATIONSFLOW RATE 10 GPM

UV INTENSITY 30mW/cm2 AT RATED FLOW

PUMP 1½ HP, 10 GPM @ 57 PSI

SUCTION INLET (PUMP) 1 INCH FNPT

SYSTEM OUTLET (PUMP) 1 INCH FNPT

RECIRCULATION OUTLET 1 INCH FNPT

FRESH WATER INLET 1 INCH FNPT

BLADDER TANK SIZE 35 GALLONS

Page 6: RW-UV Series Water Reclamation Systems Engineer Guide

6

System Dimension Information*NOTE: Additional space will be required for cistern tank (if located indoors). System designs are the property of Water Control and may not be reproduced without written permission.

System Dimensions: Model RW-UV-80

System Dimensions: Model RW-UV-120

*System dimensions and designs may be subject to change without notice.

RW-UV-80 SPECIFICATIONSFLOW RATE 80 GPM

UV INTENSITY 30mW/cm2 AT RATED FLOW

PUMP 5 HP, 80 GPM @ 50 PSI

SUCTION INLET (PUMP) 2 INCH FNPT

SYSTEM OUTLET (PUMP) 2 INCH FNPT

RECIRCULATION OUTLET 2 INCH FNPT

FRESH WATER INLET 2 INCH FNPT

BLADDER TANK SIZE 85 GALLONS

RW-UV-120 SPECIFICATIONSFLOW RATE 120 GPM

UV INTENSITY 30mW/cm2 AT RATED FLOW

PUMP 5 HP, 120 GPM @ 47 PSI

SUCTION INLET (PUMP) 3 INCH FNPT

SYSTEM OUTLET (PUMP) 3 INCH FNPT

RECIRCULATION OUTLET 3 INCH FNPT

FRESH WATER INLET 3 INCH FNPT

BLADDER TANK SIZE 120 GALLONS

Page 7: RW-UV Series Water Reclamation Systems Engineer Guide

7

System Dimension Information*NOTE: Additional space will be required for cistern tank (if located indoors). System designs are the property of Water Control and may not be reproduced without written permission.

System Dimensions: Model RW-UV-200

System Dimensions: Model RW-UV-160

*System dimensions and designs may be subject to change without notice.

RW-UV-160 SPECIFICATIONSFLOW RATE 160 GPM

UV INTENSITY 30mW/cm2 AT RATED FLOW

PUMP 10 HP, 160 GPM @ 47 PSI

SUCTION INLET (PUMP) 3 INCH FNPT

SYSTEM OUTLET (PUMP) 3 INCH FNPT

RECIRCULATION OUTLET 3 INCH FNPT

FRESH WATER INLET 3 INCH FNPT

BLADDER TANK SIZE 120 GALLONS

RW-UV-200 SPECIFICATIONSFLOW RATE 200 GPM

UV INTENSITY 30mW/cm2 AT RATED FLOW

PUMP 10 HP, 200 GPM @ 45 PSI

SUCTION INLET (PUMP) 4 INCH FNPT

SYSTEM OUTLET (PUMP) 4 INCH FNPT

RECIRCULATION OUTLET 4 INCH FNPT

FRESH WATER INLET 4 INCH FNPT

BLADDER TANK SIZE 120 GALLONS

Page 8: RW-UV Series Water Reclamation Systems Engineer Guide

8

Model Suction Inlet Recirc Outlet System Outlet Fresh Water Inlet

RW-UV-10 1 ¼” 1” 1” 1”

RW-UV-40 1 ½” 1 ½” 1 ½” 1 ½”

RW-UV-80 2” 2” 2” 2”

RW-UV-120 3” 3” 3” 3”

RW-UV-160 3” 3” 3” 3”

RW-UV-200 4” 4” 4” 4”

RW-UV-240 4” 4” 4” 4”

*System dimensions and designs may be subject to change without notice.

System Dimension Information*NOTE: Additional space will be required for cistern tank (if located indoors). System designs are the property of Water Control and may not be reproduced without written permission.

System Connection Sizes

RW-UV-240 SPECIFICATIONSFLOW RATE 240 GPM

UV INTENSITY 30mW/cm2 AT RATED FLOW

PUMP 15 HP, 240 GPM @ 63 PSI

SUCTION INLET (PUMP) 4 INCH FNPT

SYSTEM OUTLET (PUMP) 4 INCH FNPT

RECIRCULATION OUTLET 4 INCH FNPT

FRESH WATER INLET 4 INCH FNPT

BLADDER TANK SIZE 120 GALLONS

System Dimensions: Model RW-UV-240

Page 9: RW-UV Series Water Reclamation Systems Engineer Guide

9

Reclaimed WaterOut To Fixtures

Reclaimed Water Out To Irrigation

Overflow (To Drain)

Submersible Pump (On Platform At Least 6" Off Bottom)

Float Switch

Priming Port

RPZFresh Water In

RW-UV-40

SubmersiblePump Panel

Roof Drain

Reclaimed Water In

SolidsSeparator

Waste To Drain Or Grade

Suction Line

Recirc Return Line

Reclaimed Water Out

Tank Vent

Electrical Requirements

ACTUAL SYSTEMS WILL VARY. DO NOT PLUMB TO PRINT.Contact WCC for other installation configurations.

* System electrical requirements subject to change without notice.

Typical Installation: RW Series Water Reclamation System

Water Control current & power requirements for all RW-UV systemsETL, UL, & CE approval and maximum over-current protectionReference: CSA-C22.2 No. 236 -- UL 1995 Section 36 2/6/08

Pumps may be either 230V or 460V

Model Pumping Systems Control and UV Lamp Systems

Voltage Current Power Pump Voltage Current PowerAMPS KVA Hp AMPS WATTS

RW-UV-10 230/460 7.2/3.6 1.2 1½ 120 0.7 85

RW-UV-40 230/460 10.4/5.2 1.6 2 120 1.5 180

RW-UV-80 230/460 12.1/6.0 2.9 5 120 2.7 325

RW-UV-120 230/460 16.1/8.0 2.9 5 120 3.9 470

RW-UV-160 230/460 29.0/13.0 8.1 10 120 5.1 615

RW-UV-200 230/460 29.0/13.0 8.1 10 120 6.3 760

RW-UV-240 230/460 37.0/17.0 8.1 15 120 7.6 915

Page 10: RW-UV Series Water Reclamation Systems Engineer Guide

10

Standard Sytem Sample Specification(Full spec available in AIA™ format):System shall be a Water Control Corporation model RW-UV- _____ (or equal) Water Reclamation System, designed to provide a maximum of _____ GPM (at minimum 40 psi) of filtered, algae/odor/pathogen-free rainwater to fixtures/equipment such as urinals, toilets, irrigation systems, vehicle washes and/or cooling towers.System shall be mounted on a powder-coated aluminum skid and shall include a quantity of ___ ultraviolet (UV) disinfection lamps with 304 stainless steel housings, quartz sleeves, and integral UVC sensors. Lamps shall be capable of standard UV intensity of 30 mW/cm2 and absolute minimum dose of 15 mW/cm2, in order to maintain 99.99% kill rate for all common bacteria. System shall be BMS compatible and include digital UV power meter and alarm system (in NEMA 3R enclosure), properly sized pressure/cistern recirculation pump, 2 micron cartridge filter or twin/quad bag filters (10 and 5 micron) with pressure differential monitor, pressure tank and switch, cistern suction strainer, cistern float switch, fresh water bypass equipment, alarm with additional dry contacts, and automatic diverter valves for cistern recirculation.System shall be designed to channel rainwater from building roof drains and/or other reclaimable sources to cistern tank. On demand, system shall pump cistern water through cartridge or bag filter(s) for removal of particulates, through UV lamp(s) for pathogen sterilization and out to fixtures/equipment using reclaimed water.Ultraviolet disinfection system shall include integral UVC radiometer (UV sensor) for detection of ineffective UV sterilization intensity. Should UV sterilization system be rendered ineffective due to lamp life expiration, bio-slime, or water turbidity, audible alarm and red light shall be activated, signal shall be sent to BMS system, and automatic bypass valve shall initiate a system bypass whereby potable water is supplied in lieu of reclaimed water. System potable water bypass shall also be automatically initiated in the case of low cistern water level or blocked filter(s).To support cistern cleanliness and hygiene levels, system shall incorporate automatic recirculation diverter valve and controls. During periods where water is not being drawn from cistern, control system shall initiate continuous recirculation of cistern water (at ____ GPM) through UV disinfection lamp and filter array. Control shall include programmable pump timer to shut down recirculation during low-use periods.System shall include a quantity of ____ model _____ downspout filters, for filtration of dirt, moss, leaves, and insects from roof drain effluent. Each separator shall be capable of handling 5,500 ft2/33,000 ft2 (please select) roof area respectively.

CONTRACTOR SHALL PROVIDE THE FOLLOWING:• Reduced pressure zone backflow preventer on potable water bypass feed line (refer

to state codes for specific requirements).

MANUFACTURER SHALL PROVIDE THE FOLLOWING: • System delivery, setup, and startup, as well as contractor/owner training services. • Complete system CAD™ or REVIT™ layout for plan review and submittal purposes.• One-year limited warranty.

Page 11: RW-UV Series Water Reclamation Systems Engineer Guide

11

Available Options· Disinfection-Only Systems (use suffix "RC" after standard UV system model number)

Packaged systems for tank recirculation/disinfection only (no delivery system of freshwater bypass). Option for remote freshwater make-up valve.

· Fiberglass Storage Tanks 600 - 50,000 gallon (below grade only).· Corrugated Galvanized Steel Storage Tanks 700 - 700,000 gallons with water-tight membrane liner (above grade only).· Polyethylene Storage Tanks 500 - 2,500 gallons (below grade),

100 - 6,500 gallons (above grade).· Air-gap Tank Systems Potable make-up water supply systems for areas where direcG potable water

connections are not allowed, or when multiple make-up water sources are desired.· Booster Pumps On-board, remote, or submersible high-pressure pumps for large/multi-story facilities.· Ultrasonic Tank Level Sensors Up to 26' depth.· Waterflow Sensor / Totalizers With digital gallon/GPM readout.· Injector Pumps Inject food-grade dye or chlorine into water, prior to delivery.· Downspout Separators For pre-filtration of large debris from roof drainage system.· Integrated Commercial Softening Systems Reclaim nearly 70% of regeneration wastewater with an integrated Water Control

commercial softening system.· Membrane Filtration Reverse osmosis systems (with DI option) for ultra-high purity water.· Filtration-Only Systems Packaged systems with pump(s), filters, fresh water bypass, controls, and fail-safe

mechanisms (no disinfection) for sub-surface irrigation systems.

Please call for information on these or any other options.Contact Our Technical Support Department:

Phone: 1-866-405-1268 • Fax: 763-427-5665Email: [email protected]

Page 12: RW-UV Series Water Reclamation Systems Engineer Guide

12

Water Control Corporation7150 143rd Ave NW • Ramsey, MN 55303

Phone: 866-405-1268 • Fax: 763-427-5665www.watercontrolinc.com

© Water Control Corp. 0414

BUILT IN THE USA