Page 1: S9200U1000 Universal Integrated Furnace Control (UIFC) Training Module

S9200U1000Universal Integrated Furnace

Control (UIFC)

Training Module

Page 2: S9200U1000 Universal Integrated Furnace Control (UIFC) Training Module

2

• Product Overview- Universal Replacement- Features- Call for Heat, Cool and Fan

• Set Up, Installation and Troubleshooting- Cross Reference- Mounting- Selecting Wiring Harness- Safety Timings- Field Settings- LED Indicators- 2011 Product Enhancements- Interfacing with the VisionPro®

• S9200 Advantage

S9200 UIFC - What You Will Learn:

Page 3: S9200U1000 Universal Integrated Furnace Control (UIFC) Training Module

Product Overview

Page 4: S9200U1000 Universal Integrated Furnace Control (UIFC) Training Module

4

S9200U Universal Integrated Furnace Control

What is the S9200U1000?• Universal service replacement part for

use on single stage, 120VAC, Silicon carbide hot surface ignition furnaces

• Replaces over 140 models!

• Electronic circuit board that controls the operation of the furnace, air conditioner (on/off), humidifier (on/off) and electric air cleaner (on/off)

• Applicable for use on 25M+ furnaces installed in the United States and Canada between 1991 and 2006

• The “brain” for most single state, HSI furnaces built in the ’90’s

One part number:S9200U1000

Page 5: S9200U1000 Universal Integrated Furnace Control (UIFC) Training Module

5

Key S9200U UIFC Features

• Universal Application• Keyed wiring harnesses are included with the product for simple installation of most single stage HSI IFC’s

• Less time scouring the shelves for the exact part and installation is done in a few simple steps

• Robust Diagnostics• On-board LED flame signal strength indication• System status (performance and diagnostics)

• EnviraCOM™ communications enabled• Capability to enable local and/or remote status, diagnostics, troubleshooting, and HVAC system control

Page 6: S9200U1000 Universal Integrated Furnace Control (UIFC) Training Module

6

ERASINGLE/

TWO STAGE

IGNITION ARCHITECTURE

IGNITION SOURCE

HON CONTROL FUNCTIONS COMMENT

<1980 SINGLE STANDING PILOT PILOT NA NA NA

1980s SINGLE INTERMITTENT PILOT SPARK S8610UIGNITION CONTROL

SEP FAN TIMER CONTROL

1980s, 1990s

SINGLE DIRECT HOT SURFACE S8910IGNITION CONTROL

LOW VOL; SEP FAN TIMER CONTROL

1990s, 2000s

SINGLE DIRECT, IP HOT SURFACE SMART VALVEIGNITION W/

VALVE

8M INSTALLED; SEP FAN TIMER CONTROL

1990s, 2000s

SINGLE DIRECT HOT SURFACE S9200IGNITION, FAN, BLOWER, AC,

EAC, HUMIDIFIER25M+ INSTALLED

2000s TWO DIRECT HOT SURFACE NONEIGNITION, FAN, BLOWER, AC,

EAC, HUMIDIFIER

STILL UNDER WARRANTY

Product Overview: Position in Portfolio

ERASINGLE/

TWO STAGE

IGNITION ARCHITECTURE

IGNITION SOURCE

HON CONTROL FUNCTIONS COMMENT

<1980 SINGLE STANDING PILOT PILOT NA NA NA

1980s SINGLE INTERMITTENT PILOT SPARK S8610UIGNITION CONTROL

SEP FAN TIMER CONTROL

1980s, 1990s

SINGLE DIRECT HOT SURFACE S8910IGNITION CONTROL

LOW VOL; SEP FAN TIMER CONTROL

1990s, 2000s

SINGLE DIRECT, IP HOT SURFACE SMART VALVEIGNITION W/

VALVE

8M INSTALLED; SEP FAN TIMER CONTROL

1990s, 2000s

SINGLE DIRECT HOT SURFACE S9200IGNITION, FAN, BLOWER, AC,

EAC, HUMIDIFIER25M+ INSTALLED

2000s TWO DIRECT HOT SURFACE NONEIGNITION, FAN, BLOWER, AC,

EAC, HUMIDIFIER

STILL UNDER WARRANTY

Through the 1990’s and into the 2000’s, 25M+ controls were installed in single stage HSI furnaces. These units are no longer under warranty and this presents a large replacement opportunity for the S9200.

Page 7: S9200U1000 Universal Integrated Furnace Control (UIFC) Training Module

7

• The key to making a universal replacement work:

Product Overview – S9200U

Specialwiring

harness

Connects old cableto new board

Page 8: S9200U1000 Universal Integrated Furnace Control (UIFC) Training Module

8

Product Overview – What does it do?

• On a Call For Heat, the UIFC:

-Manages the ignition process Checks safety interlocks to insure ok to ignite Provides power to Hot Surface Igniter Energizes induced draft blower motor & gas valve Detects flame presence Turns circulating fan on at end of heat on delay

-Turns Humidifier, Electric Air Cleaner On (If present)

-Monitors safe operation of furnace

-Manages furnace shut down at end of call for heat Close gas valve, turns Humidifier, EAC, induced draft blower off Turns circulating fan off at end of fan off delay

Page 9: S9200U1000 Universal Integrated Furnace Control (UIFC) Training Module

9

Product Overview – What does it do?

• On a Call for Cool, the UIFC- Energizes Cooling Contactor- Turns Circulating Fan On (at end of cool on delay)

- Manages Air Conditioner shut down at end of call for cool De-energize contractor, turn fan off (at end of cool off delay)

• On a Call For Fan:- Turn Circulating Fan On

• Provides Robust Diagnostic Information:- Three Diagnostic LEDs:

Amber LED: Flame strength Red LED: Sequence of Operation & Alarm Information Green LED: EnviraCOM status

- EnviraCOM Communications: EnviraCOM alarms available for display on VisionPro IAQ

Page 10: S9200U1000 Universal Integrated Furnace Control (UIFC) Training Module

Set Up, Installation and Troubleshooting

Page 11: S9200U1000 Universal Integrated Furnace Control (UIFC) Training Module

11

Step 1 – Cross Reference

• Find the exact model number of the old control in the cross reference

- United Technologies

- Rheem

- Nordyne

- Texas Instruments

- York

- White-Rodgers

- Goodman

- ICM

- Trane

Page 12: S9200U1000 Universal Integrated Furnace Control (UIFC) Training Module

12

Step 2 - Select Wiring Harness

• Choose the correct wiring harnesses for the control you are replacing

• Use Cross Reference

DMain Connector

CInducer & HSI Connector

Page 13: S9200U1000 Universal Integrated Furnace Control (UIFC) Training Module

13

Step 3 - Tag Wires

• Before removing any wires from the old board . . .

• Use tape to label each of the individual wires leading to the IFC board- This is just a

suggestion, not a necessary part of installation.

- No need to label wires on mutli-wire plug

• Remove the existing board

Page 14: S9200U1000 Universal Integrated Furnace Control (UIFC) Training Module

14

Step 4 - Mount the UIFC

• Mount in same location as old control- All existing wires should

reach to the new control

• Mount vertically - (surface of the board

going up and down)

• Be sure the board won’t get wet - (from condensation or

leaky humidifier, etc.)

Page 15: S9200U1000 Universal Integrated Furnace Control (UIFC) Training Module

15

Step 5 - Plug In Harness

• Harness connects from old plug to new board

• Re-connect individual wires to line voltage loads

• Reconnect thermostat wires

Page 16: S9200U1000 Universal Integrated Furnace Control (UIFC) Training Module

16

Step 6 - Set Safety Timings

• Switch S2• Get recommended settings from Cross Reference

Page 17: S9200U1000 Universal Integrated Furnace Control (UIFC) Training Module

17

Safety Timings

* The shorter of the two periods listed (17 seconds) applies to the first trial only, while the longer period (27 seconds) applies to the subsequent trials during the same call for heat.

Page 18: S9200U1000 Universal Integrated Furnace Control (UIFC) Training Module

18

Step 7 - Field Settings

• Switch S1• Get settings from Cross Reference

COOLFANOFF

DELAY

HEATFANON

DELAY

HEATFANOFF

DELAY

Page 19: S9200U1000 Universal Integrated Furnace Control (UIFC) Training Module

19

Field Settings

Page 20: S9200U1000 Universal Integrated Furnace Control (UIFC) Training Module

20

Step 8 - Safety Timing Lockout Jumper

• Remove jumper to lock-in safety timings

Or

• Settings become permanent after the 10th full operating cycle with the new safety timings even if the jumper is not removed

Page 21: S9200U1000 Universal Integrated Furnace Control (UIFC) Training Module

21

LED Indicators

• FLAME (Amber)- Signals low flame current

• STATUS (Red)- Fault codes

• E-COM (Green)- Shows presence of

traffic on the EnviraCOM™ circuit

FLAME

STATUS

E COM

Page 22: S9200U1000 Universal Integrated Furnace Control (UIFC) Training Module

22

2011 S9200U1000 Enhancements

• S9200U1000 single-stage hot surface ignition integrated furnace control is now shipping with the following enhancements:- Simplified instructions and wiring harness labels

- New included jumper wire to allow installation in some applications

- New packaging

• Enhancements implemented with 1106 date codes

Page 23: S9200U1000 Universal Integrated Furnace Control (UIFC) Training Module

23

Date Code Location

• Date code: 1106

Page 24: S9200U1000 Universal Integrated Furnace Control (UIFC) Training Module

24

Wiring Harness Labels

• Harnesses labeled A – G

• Harnesses now referenced by letter in the installation instructions form 69-2075

Page 25: S9200U1000 Universal Integrated Furnace Control (UIFC) Training Module

25

New Jumper

• There is a jumper wire labeled 50049508-001. • This wire is provided to jumper the rollout pins, pins

5 & 11 on the S9200U1000 – used on Trane boards

Page 26: S9200U1000 Universal Integrated Furnace Control (UIFC) Training Module

26

Jumper Installation

• Some applications require the OEM connector plug to jumper the 5 and 11 rollout pins

• See Figure 2 on page 7 of I & I sheet 69-2075

321

654

987

121110

Page 27: S9200U1000 Universal Integrated Furnace Control (UIFC) Training Module

27

Jumper Installation

• Apply the jumper to the corresponding pins on the OEM connector and insert jumper wire

Jumper pins must be fully inserted and locked or control may not function

Page 28: S9200U1000 Universal Integrated Furnace Control (UIFC) Training Module

28

Jumper Installation

• Plug OEM connector with installed jumper wire into the board

Verify jumper pin locations before connecting to board

Page 29: S9200U1000 Universal Integrated Furnace Control (UIFC) Training Module

29

New Packaging

• Similar look and feel across the portfolio• Updating packaging along with product

enhancements now shipping

Page 30: S9200U1000 Universal Integrated Furnace Control (UIFC) Training Module

30

Interfacing With The VisionPRO® IAQ

• If the VisionPro IAQ is part of the system with the S9200, there is an added advantage of EnviraCOM alarm alerts at the thermostat.

• Example if a Rollout Limit Opens “Err 87” will appear along with a red light in the upper right-hand corner.

Page 31: S9200U1000 Universal Integrated Furnace Control (UIFC) Training Module

Product Cross Reference

Page 32: S9200U1000 Universal Integrated Furnace Control (UIFC) Training Module

32

Product Cross Reference

• Where do I find Honeywell electronic ignition cross reference and selection information?

- www.customer.honeywell.com

- S9200U Cross Reference Guide - Form 63-9715

- Technician’s Quick Reference Guide – Form 69-2087

- Honeywell Application Selection and Cross

Reference Guide – Form 63-9575

- Honeywell Residential Technical Support: 1-800-468-1502

Page 33: S9200U1000 Universal Integrated Furnace Control (UIFC) Training Module

33

www.customer.honeywell.com

• See Cross Reference Search box in right column.

Page 34: S9200U1000 Universal Integrated Furnace Control (UIFC) Training Module

34

• When promoting the S9200U, keep these advantages in mind:

• A Universal control. This single controls replaces over 140 identities, and with the keyed wiring harnesses included, finding the right part and installation are a snap!

• Save time looking for the right part• Installation in just a few simple steps• Less parts to stock saves time and money stocking ONE control instead of

many that you may not use

• The on-board LED flame signal and system status indicators make diagnosing and troubleshooting simple.

• Save time and reduce callbacks• Less time correcting problems equals satisfied customers

• The EnviraCOM™ communications enabled added advantage provides:• Local and/or remote status monitoring, diagnostics, troubleshooting, and

HVAC system control

S9200U Advantages

Page 35: S9200U1000 Universal Integrated Furnace Control (UIFC) Training Module

S9200U1000Universal Integrated Furnace

Control (UIFC)

Knowledge Test

Page 36: S9200U1000 Universal Integrated Furnace Control (UIFC) Training Module

36 HONEYWELL - CONFIDENTIAL File Number

• Now that you completed this training module, take the short quiz to test your knowledge.

S9200U UIFC Knowledge Test

Page 37: S9200U1000 Universal Integrated Furnace Control (UIFC) Training Module

37 HONEYWELL - CONFIDENTIAL File Number

Test

1. The S9200U is a replacement control for Hot Surface Ignition (HSI) furnaces? T or F

2. In addition to controlling the furnace, the S9200 can also control the electronic air cleaner, humidifier, and air conditioner? T or F

3. The S9200 cannot control the circulating fan? T or F

4. The replacement opportunity for this control is small and should be short-lived? T or F

5. The key to replacement with this universal control are the wiring harnesses that replace over 120 identities? T or F

Page 38: S9200U1000 Universal Integrated Furnace Control (UIFC) Training Module

38 HONEYWELL - CONFIDENTIAL File Number

Test

6. Safety timings and field settings are easily set following the cross reference instructions and setting the dip switches? T or f

7. The jumper must be cut to lock in the safety timings, or they will never be locked in? T or F

8. The S9200 has three (3) LED’s to monitor flame, fault codes and EnviraCOM status? T or F

9. If a VisionPro IAQ is installed as part of the system, the EnviraCOM error codes will appear on the thermostat? T or F

10. If you can’t find a cross reference for an existing control you should:

a) Guess and hope for the best, or

b) Call Honeywell Residential Technical Support

Page 39: S9200U1000 Universal Integrated Furnace Control (UIFC) Training Module

39 HONEYWELL - CONFIDENTIAL File Number

Answer Key

1. T2. T3. F4. F5. T6. T 7. F8. T9. T10.B