sa stc mr 2g 3g lte mop ver2 2

39
1 © Nokia Siemens Networks Presentation / Author / Date MR 2G, 3G and LTE MoP version 2.0 SA STC, project

Upload: abdallahmohmmed

Post on 04-Oct-2015

30 views

Category:

Documents


2 download

DESCRIPTION

m

TRANSCRIPT

  • 1 Nokia Siemens Networks Presentation / Author / Date

    MR 2G, 3G and LTE MoP version 2.0

    SA STC, project

  • 2 Nokia Siemens Networks Presentation / Author / Date

    Part 1: 2G Site model Categories & Configuration for modernization

    As per the BoQ: 2G 900:6+6+6, 2G 1800:4+4+4 ( 1 SM + 2 RFM GSM900 + 2

    RFM GSM1800 )

    No Model Configuration No. of System

    Module No. of RF Modules

    Typical O/P Power per

    TRX

    No. of antenna lines per sector

    1 4+4+4 1 2 20 W 2

    2 6+6+6 1 2 20 W 2

    3 8+8+8 1 3 20 W 3

    4 12+12+12 1 3 15 W 3

    5 6+6+6/4+4+4 1 4 20 W 2/2

    6 6+6+6/6+6+6 1 4 20 W 2/2

    7 6+6+6/8+8+8 2 5 20 W 2/3

    8 8+8+8/6+6+6 2 5 20 W 3/2

    9 8+8+8/8+8+8 2 6 20 W 3/3

    10 8+8+8/12+12+12 2 6 15 W 3/3

    11 12+12+12/4+4+4 2 4 15 W 3/2

    12 12+12+12/8+8+8 2 6 15 W 3/3

  • 3 Nokia Siemens Networks Presentation / Author / Date

    Part 1: 2G BTS System Module

  • 4 Nokia Siemens Networks Presentation / Author / Date

    Part 1: 2G BTS RF Module

  • 5 Nokia Siemens Networks Presentation / Author / Date

    Part 1: 2G BTS Product Structure

    Flexi Multiradio 10 BTS For 2G/3G/LTE/LTE-A

    Pipe 1

    Div Rx

    Tx 60W/Rx

    Pipe 2

    Div Rx

    Tx 60W/Rx

    Pipe 3

    Div Rx

    Tx 60W/Rx

    3G or LTE BB

    extension

    Optional transport

    interfaces Optional PDU

    3G or LTE / BB

    extension

    Flexi RF Module Triple

    (3x60W) or (3x20W)

    2G/3G/LTE/LTE-A

    Flexi Multiradio

    System Module,

    2G/3G/LTE/LTE-A

    Alternativ

    e RRH

    site

    solution

    Alternative

    Active

    Antenna

    site

    solution

    Alternative

    Indoor

    System

    Module

    2G, 3G or LTE baseband core

    Integrated IP transport

    Existing Flexi RF Modules/RRHs can

    be also connected to Flexi Multiradio

    System Module

  • 6 Nokia Siemens Networks Presentation / Author / Date

    Flexi MR BTS is structured based on 6+6+6 TRX Module

    6+6+6 / 4+4+4

  • 7 Nokia Siemens Networks Presentation / Author / Date

    Part 1: Feeder Connection to 2G Antenna

  • 8 Nokia Siemens Networks Presentation / Author / Date

    Part 1: Feeder Connection to 2G Antenna

    10W + 10W

    6 TRXs

    (20W)

    6+6+6 @ 900MHz

    4+4+4 @1800MHz

  • 9 Nokia Siemens Networks Presentation / Author / Date

    Part 1: 2G BTS feeder configurations

    A

    (max)6/6/6@10w per TRX or

    3/3/3@ 20w per TRX or

    4/4/4@15w per TRX or

    2/2/2@20w/30w per TRX

    1/1/1@60w per TRX

    12/12/12 @10w per TRX or

    8/8/8@15w per TRX or

    6/6/6 @ 20w per TRX or

    4/4/4 @ 20w per TRX

    2/2/2 @60w per TRX

    8 /8/8 @20w per TRX or

    9/9/9 @ 20w per TRX or

    12/12/12 @15w per TRX or

    2/2/2@30w per TRX or

    One sector shown

  • 10 Nokia Siemens Networks Presentation / Author / Date

    12/12/12 @10w per

    TRX or

    8/8/8@15w per TRX or

    6/6/6 @ 20w per TRX or

    4/4/4 @ 20w per TRX

    2/2/2 @60w per TRX

    ESMB=max18TRx.

    FXDA-900

    FXEA-1800

    Use sync cable for CBCCH if bands are in separate BCF

    Example: when total TRX is more than 36.

    900

    8/8/8 or

    12/12/12

    1800

    8/8/8 or

    12/12/12

    If the number of TRX is less than 36

    RF chaining can be used for special configurations

    or more sectors

  • 11 Nokia Siemens Networks Presentation / Author / Date

  • 12 Nokia Siemens Networks Presentation / Author / Date

    Part 1: BTS with smaller configuration than 8 TRX example

    900

  • 13 Nokia Siemens Networks Presentation / Author / Date

    2G MOP to Configure more than 6+6+6 / 4+4+4 example

  • 14 Nokia Siemens Networks Presentation / Author / Date

  • 15 Nokia Siemens Networks Presentation / Author / Date

  • 16 Nokia Siemens Networks Presentation / Author / Date

  • 17 Nokia Siemens Networks Presentation / Author / Date

    Example

    Site: ZMKA007

    BSC GK12B3

    6+8+6(900) / 4+8+4 (1800)

  • 18 Nokia Siemens Networks Presentation / Author / Date

  • 19 Nokia Siemens Networks Presentation / Author / Date

  • 20 Nokia Siemens Networks Presentation / Author / Date

    Sample of configuration difference between Old BTS type versus Flexi MR

    DTRX

    MultiRadio

    WCDMA

    DTRX

    WBC Diplexer

    43W 20W 17W

    20W/15W

    3+3+3/4+4+4 Configuration

  • 21 Nokia Siemens Networks Presentation / Author / Date

    Sample of configuration difference between Old BTS type versus Flexi MR (1/2)

    DTRX

    MultiRadio

    WCDMA

    DTRX

    WBC

    Diplexer 43W 20W

    8.7W

    10W

    DTRX WCDMA WBC

    6W WBC

    5+5+5/6+6+6 Configuration

  • 22 Nokia Siemens Networks Presentation / Author / Date

    Sample of configuration difference between Old BTS type versus Flexi MR (2/2)

    DTRX

    MultiRadio

    WCDMA

    DTRX

    WBC Diplexer

    43W

    20W 17W

    10W

    DTRX WCDMA WBC Diplexer

    43W 20W 17W

    5+5+5/6+6+6 Configuration

  • 23 Nokia Siemens Networks Presentation / Author / Date

    2G A-bis Timeslot mapping table

    NOTES

    The above A-bis mapping is for the standard A-bis configuration which is appearing most of the time in the network

    Any odd configuration to be planned by NPO and shared with the rest of the team before MDT

  • 24 Nokia Siemens Networks Presentation / Author / Date

    Part 2: 3G Site model Categories & Configuration for Modernization

    The 3G configuration is based on 2 - 4 carriers. All configurations are based on 30 W per carrier.

    2+2+2 or 4+4+4 Flexi MR with FSME

    3+3+3@42Mbps

    software upgrdable to

    4+4+4@84Mbps

  • 25 Nokia Siemens Networks Presentation / Author / Date

    3G 3+3+3 @ 42 Mbps upgradable to 4+4+4 @ 84Mbps

    Sector 1

    Div Rx Tx/Rx

    Rx Out Rx Out Rx Out

    Sector 2

    Div Rx Tx/Rx

    Sector 3

    Div Rx Tx/Rx

    1Rel99 Carrier + 2 HSDPA carriers

    consecutive

    Upgradable to 4+4+4 @84Mbps with 4

    consecutive carriers

    Single Band Antenna 3G

    2100MHz

    Existing Antenna will

    remain unchanged

  • 26 Nokia Siemens Networks Presentation / Author / Date

    Part 2: 3G Multiradio Configuration

    2+2+2/3+3+3/4+4+4

    1+1+1/2+2+2

    Site configuration WCDMA

    FSME+2x FRGP. FTIB or FTPB or FTFA/B

    BTS Rx Signal Level must be smaller than -102dBm during

    commissioning

  • 27 Nokia Siemens Networks Presentation / Author / Date

    Part 2 : 3G Multi Radio MRC to be removed from existing

    No MRC to be used with Flexi Multi Radio

  • 28 Nokia Siemens Networks Presentation / Author / Date

    Part 3: LTE Site Configuration Model

    DC cable

    Optical cable

    The LTE configuration : 1+1+1 LTE, 2x2

    MIMO @2300 MHz

  • 29 Nokia Siemens Networks Presentation / Author / Date

    Part 3: LTE Flexi Multi Radio configuration

  • 30 Nokia Siemens Networks Presentation / Author / Date

    Part 3: LTE Multi Radio Configuration

  • 31 Nokia Siemens Networks Presentation / Author / Date

    ONE BTS type for all Technologies

    Flexi EDGE System Module

    6+6+6 , 4+4+4 TRX

    Flexi 3G/LTE System Module

    3+3+3 WCDMA @2100MHz

    1+1+1 LTE, 2x2 MIMO

    @ 2300MHz TDD

  • 32 Nokia Siemens Networks Presentation / Author / Date

    Power consumptions

  • 33 Nokia Siemens Networks Presentation / Author / Date

    Clock Synchronization

    Timing over packet for 2G BTS (Not Co-located with 3G Node-B)

    The RAN synchronization is based on Timing Over Packet following standard IEEE 1588. One ToP master clock can synchronize up between 800 NE. The ToP will be connected to CE Router as 1+1 ( Active and Standby ) as shown below.

    The O&M connectivity for ToP as below. The Symmetricom O&M connectivity will be a single connection to COMIS router as hardware limitation.

  • 34 Nokia Siemens Networks Presentation / Author / Date

    Clock Synchronization

    Timing over packet for 2G BTS (Co-located with 3G NodeB)

    Synchornization to other system modules can also be done based on IEEE1588-2008, provided other system modules support IEEE1588-2008 slave functionality. ToP Engineering rule should be taken into

    account.

    1. Current 2G GSM - through PCM E1

    2. 3G WCDMA Timing over Packet (TOP)

    3. LTE - GPS

  • 35 Nokia Siemens Networks Presentation / Author / Date

    2G/3G Modernization

    GSM

    1. Existing Dump to be used as a reference

    2. Existing Physical site database as a reference

    3. 2G Parameter/new frequency plan in case new configuration is needed (for

    example TRX upgrade), For 3G Parameter/SC plan in case new configuration is

    needed (for example Carrier upgrade)

    4. A-bis timeslot mapping generated by the planning team to be followed

    5. XML creation to be done in a case the site configuration changed (existing

    parameters to be used if no upgrade)

    6. the above XML to be sent to CM team for implementation

    7. Site integration report received from NI after integration

    8. NPO will check the parameter consistencies, health check (alarms), and initial KPI

    9. Post modernization Drive test to be done to verify the hardware and swap feeders

    10.KPI reports to be submitted to STC optimization for acceptance

    11.Site accepted and passed to Managed Services

  • 36 Nokia Siemens Networks Presentation / Author / Date

    2G/3G Modernization ( Swap from Other Vendor)

    Final Swap (Cold Swap) :

    1.All NSN BTS sites with required E1s and BSCs /RNC are deployed, commissioned and integrated.

    2.All routing plans in the MSC verified and found to be correct.

    3.The RF parameters for all swap BTS sites have been matched up with the existing RF settings in old vendor network, so that the two networks have same RF parameters after swap.

    4.Drive test vehicles are available

    Activities :

    1. Disable old BTS sites by giving commands.

    2. Remove all Jumpers from Old BTS by Locking the TRX.

    3. Connect the NSN BTS to the Existing Feeder line with new jumpers.

    4. Once all six cables are properly connected, Powered on the NSN Flexi Modules.

    5. Connect the E1 and check OMU become functional.

    6. Unlock the DTRX.

    7. Display the status of the BTS at the GNSC, and confirm that all devices are Installed and

    Operational.

    8. Drive test teams should start the activity after the site is On Air

  • 37 Nokia Siemens Networks Presentation / Author / Date

    2G/3G Modernization ( Swap from Other Vendor)

    HOT SWAP :

    In case of HOT SWAP installation and commissioning of NSN BTS to be done during the outage period only.

    However following pre-requisites needs to be confirmed:

    1. Availability of Manpower and Tools.

    2. Installation material availability.

    3. Confirmation of site Access during outage time.

  • 38 Nokia Siemens Networks Presentation / Author / Date

    Modernization Fall Back Procedure

    2G

    1. Save the latest dump

    2. Extract the site parameters / configurations by clicking the Backup plan in

    NetAct using XML format before deleting the site

    3. Save this file

    4. During fall back, re-run this XML file to re-create the site

    5. Re-create A-bis and ADJx based on the dump

    6. The field team must retrieve the old commissioning and A-bis plan

    3G

    1. There is no parameter change during modernization

    2. The same parameters exists in NetAct so only equipment change over

    to be done

  • 39 Nokia Siemens Networks Presentation / Author / Date

    Add New LTE

    1. Existing Physical site database as a reference in case of collocation

    2. Parameter planning and creation

    3. XML creation

    4. XML to be sent to CM team for implementation

    5. Site integration report received from NI after site integration

    6. NPO will check the parameter consistencies, health check (alarms), and initial KPI

    7. Drive test to be done to verify the hardware and swap feeders

    8. Site locked and to be unlocked for testing purpose

    9. KPI reports to be submitted to STC optimization for acceptance

    10.Site accepted and passed to Managed Services