Safety Compass
FOCUS ON THIS MONTH : FIRE MAIN ISOLATING VALVE
There was a deficiency case for Fire Main Isolating valve during SIRE inspection of company ves-
sel. For checking/managing the isolating valve on-board, please refer to the role of Main Isolat-
ing valve and corrective actions about the deficiency case.
◇ Significant Near-miss Investigation Report
► MAIN ENGINE STARTING FAIL DURING BERTHING
◇ Marine Incident Cases
► Risk of Collision following Non-Performance of the
Method to Avoid Agreed by Mutual Communi-
cation
► Not restoring of isolation of fire alarm after
working
◇ Information for Ship
► Prohibition of Personal Electric Heater use on
board
◇ PSC NEWS
► Detention cases of KR registered vessels in the
fourth quarter, 2019
◇ Acute appendicitis
► Cause, Symptom
► Caution
2
Safety Compass (2020.02)
FIRE MAIN ISOLATING VALVE
● Isolating valve is installed to transfer seawater from the Em’cy Fire pump to the hydrant
properly when using Em’cy Fire pump.
● The isolating valve is installed at previous point, where the pipe derived from the main fire pump
meets the pipe derived from the Em’cy Fire pump, and the isolating valve must be installed out-
side of the engine room.
● Em’cy Fire pump would be used when the main Fire pump is not available due to fire in the en-
gine room or damage to the fire pipe. If the isolating valve is not installed, seawater from the
Em’cy Fire pump may flow into the engine room and fail to supply the seawater with suffi-
cient flow rate & pressure to the fire hydrant in need of seawater. In addition, the isolating
valve must be installed outside the engine room because unavailability of the Main Fire pump
means it is most likely in situations that access to inside of the engine room is impossible.
1. Role of Main Isolating Valve
■ Disassembled the valve and cleaned BODY, DISC and VALVE STEM THREAD
■ After re-assemble, checked that the valve fully closed without leakage (During Fire pump running,
pressure decreased when valve was closed.)
2. Deficiency
■ After operating the Main Fire pump, the pressure in the fire line was 7 bar. The Main Isolating
valve in Foam room was closed, but the 7 bar was sighted on the upstream side of the
valve(pressure gauge).
⇒ Main isolating valve separating the Engine room and Deck failed to close. (Leakage)
3. Corrective Action (See photos in following page)
■ Remark of Isolating valve leakage check items will be added on M&I Checklist.
4. 예방조치
3
Safety Compass (2020.02)
FIRE MAIN ISOLATING VALVE
G/S/Fire Pump Start 1535LT
▶ DISASSEMBLING
▶ CLEANING
▶ TEST
Fire Main line Pressure “0”Mpa Isolating valve Full shut 1536LT
4
Safety Compass (2020.02)
Significant Near-miss Investigation Report
MAIN ENGINE STARTING FAIL DURING BERTHING
1) Summary
■ During entering port of Pusan, M/E No.5 Cyl. Starting Air Pilot V/V Loop Fail Alarm occurred and failed
to start the engine for Dead Slow Astern in W/H.
■ When operated the engine as “Air run” by switching M/E control to engine Local station, engine RPM
did not change and confirmed that starting air was not supplied for No.5 Cyl.
■ After conduct M/E Turing about 90 degree, Dead Slow Ahead / Astern Test was done successfully and
M/E operated normally and changed Engine Control Station : Local → E.C.R → W/H
■ After alongside the pier, found that the cable which connected from E95-45 J/Box to M/E No.5 Cyl.
Starting Air Pilot V/V was damaged, so renewed the cable.
2) Root Causes
◇Damaged cable which connected from E95-45 J/Box to M/E No.5 Cyl. Starting Air Pilot V/V
3) Lesson learned
◇ In the vessel(M/E : WARTSILA 14RT-Flex 96C-B), M/E starting fail may occur if 14 cylinders are
fitted but no starting air is injected even with one cylinder.
◇ Starting air injection to cylinder is ordered each FCM(Flex control mod-
ule) received crank angle sensor. According to crank angle position, en-
gine starting is possible without problem. However, if starting air failed
cylinder is TDC position, engine starting could be failed.
▶ While cylinder cover overhauling, extremely have caution for damage
of electric cables.
▶ If starting air failed for one cylinder, vessel have to take action im-
mediately, engaging turning gear and turning crankg angle about 30
deg. With ahead(or astern) direction for starting.
▶ Take action immediately and report with RM-Record for below items.
1) Check protection tubes and electric cables for all cylinder starting air pilot
cable. If found cable or tube damage, repair ASAP.
2) Do visual inspection for cables near M/E cylinder cover and repair cable
if need.
3) If Starting Air Pilot V/V loop fail occurs intermittently during main engine
starting, check root cause (cable damage, tightening of pilot solenoid coil
plug DF93627) without delay.
Overview of Cyl. cover
Damaged cable
5
Safety Compass (2020.02)
Risk of Collision following Non-Performance of the Method to Avoid Agreed by Mutual Communication
Marine Incident Cases
As a result of observation after discovering a fishing boat approaching from the starboard of this vessel
which was navigating, a situation of a fishing boat passing to the stern of this vessel was confirmed to
at one mile from the CPA(Closest Point of Approach). After that, as the fishing boat tried to pass the bow
of his vessel by increasing speed, it was mutually agreed to pass the stern of this vessel by reducing
speed from working on fishing as as result of verifying the intention with VHF after checking the AIS
(Automatic Identification System) information. Although the precaution was not taken by confirming the
reduced speed of vessel, the radar CPA alarm sounded as the fishing boat approached by increasing
speed once again. When the reason for not keeping the promise with VHF after passing to the stern of
fishing boat by suddenly making a significant angle change to the starboard was asked, it was notified
that the promise was broken unavoidably because they were fishing.
● After mutually agreeing on the evacuation method, the fishing boat does not keep the promise
● Neglecting the duty of precaution until the other vessel passes by completely
1) Potential Accident Factors
2) Precautions for Accident Prevention
● Comply with the evacuation method agreed by mutual communication
● Observe the other vessel until it passes by completely
6
Safety Compass (2020.02)
Not restoring of isolation of fire alarm after working
Marine Incident Cases
Must Comply!(Preventive Lesson)
● When fire alarms are disabled for the working area, put an easy-to-find notice board near the
fire alarm panel so that it can be seen easily
● (Captain) Management and training periodically of on duty handover
(Chief Engineer) Continuous management for the start/stop of work
7
Safety Compass (2020.02)
In winter, there is a high possibility of fire due to increased use & short circuits of electric
heaters in homes, offices, and ships. Please refer to the following safety regulations and take
caution for using electric heater on board.
Prohibition of Personal Electric Heater use on board
▣ SAFETY RULES FOR THE USE OF ELECTRIC HEATERS
○ Do not use personal electric heaters on board
(Unauthorized heaters, personal electric blanket/pad/sitting mat, electric iron, defective
personal electric heating device, etc.)
⇒ For unavoidable reason, use only after obtaining the Master’s permission in advance, only
provided that automatic power cut-off is attached
○ Do not use defective electric socket, plug, cable
○ When leaving your cabin for Watch/Daywork or other reasons, turn off electric devices and
pull out power plug
○ Do not insert multiple electrical appliances into one outlet or socket.
○ Periodically remove dust from electrical outlets (short circuit caused by dust increases fire
risk)
○ Do not put other electronic devices, such as cell phones, on the electric heater
(Accumulated battery heat increases the possibility of ignition)
8
Safety Compass (2020.02)
PSC NEWS
Please refer to following detention cases of KR registered vessels in the fourth quarter, 2019
1. Putian, China (BULK, 08/2019)
► DETENTION ITEM
1)Three leakage parts in Fire main pipe
(between 1/2, 4/5, and next to 6 cargo hold)
2) Poor weather tight of S/G room door
2. Nanjing, China (OIL TANKER, 10/2019)
► DETENTION ITEM
1) Malfunction of No.1 S/G
2) Cut of Fixed CO2 Fire extinguisher Starting
pipe line
3. Deasan, Korea (OIL TANKER, 10/2019)
► DETENTION ITEM
1) Flame detector for local fire-fighting at
No.2 G/E was interrupted by the pipe
2) Detention code was given as SMS FAILURE
due to numerous deficiencies
4. Gwangyang, Korea (CARGO SHIP, 10/2019)
► DETENTION ITEM
■ Non-conformity of education/drill records
& lack of familiarization with enclosed
space entry/rescue drill
5. Nigata, Japan (OIL TANKER, 10/2019)
► DETENTION ITEM
1) Lack of familiarization with drowning res-
cue drill
2) Senior officers were not familiar with their
duties and authority(ISM Code)
6. Novorossiysk, Russia (BULK, 10/2019)
► DETENTION ITEM
■ Switch of Fire Detection Panel at bridge
was off
9
Safety Compass (2020.02)
PSC NEWS
7. Salerno, Italy (BULK, 10/2019)
► DETENTION ITEM
1) There was difference between the remain-
ing quantities of M/E Scav. Air box drain
tank(0.2㎥) and actual(0.12㎥) on oil record
book records
2) Lots of oil drums(waste oil for landing and
for cargo crane lub. oil) were located nexte
to the hatch coaming of cargo hold
8. Shanghai, China (CNTR, 10/2019)
► DETENTION ITEM
■ SMS Failure
- Malfunction of No.1 M/E L.O pump not re-
ported
- 2/E’s Work & Rest hour record not
matched with actual(drill participation time
was recorded as rest time)
- Omission of Work & Rest hour record
(date of inspection)
- Omission of entry permit when enclosed
space rescue drill
9. Deasan, Korea
(OIL/CHEMICAL TANKER, 11/2019)
► DETENTION ITEM
1) Defective oil filtering device
(15ppm alarm system malfunction)
2) Poor operation of Funnel dampers(4 pcs)
3) Poor operation of E/R Fan damper(2 pcs)
10
Safety Compass (2020.02)
Acute appendicitis
◆ Acute appendicitis
▶ The pocket-shaped organs located on area con-
nected from the small intestine to the large intes-
tine is called appendix. The appendicitis that we
call common is inflammation of the thin, long
vermiform appendix at the end of the appendix,
and the exact name is acute appendicitis.
◆ Causes
▶ The acute appendicitis is caused by clogging of
appendix for any reason. There are three main
reasons why the appendix is clogged.
< Causes of appendix clogging>
When the appendix is clogged, bacteria increase
inside the appendix, and by secreting toxic sub-
stances, the appendix becomes inflamed, causing
internal mucous membrane damage and ulcera-
tion.
There have been occasional cases of disembarkiation due to acute appendicitis on board. Please refer to below
information on the causes and major symptoms of acute appendicitis for personal health care.
◆ Symptoms
■ Mobile pain that not stay in one place.
■ Initially appetite decreases and nausea occur
■ Vomiting
■ Feeling bloated like indigestion and pain around so-
lar plexus
■ Over time, pain around solar plexus passes navel and
changes into pain in the right lower abdomen.
■ Pain when press the right lower abdomen with hand
■ Oppressive pain when pressing McBurney’s point
■ Slight fever and chill
■ If the appendix bursts due to hole, the pain becomes
more severe and the pain area spreads to the entire
abdomen.
■ High fever may appear, heart rate increases
▶ If neglect for more than 3 days after the symp-
toms start, the appendix will burst. This leads to
the peritonitis that pus inside the appendix spreads
through the abdomen and could lead to serious
complications such as sepsis.
1/3 of the point on the imaginary line
connecting the protruding bone of
front pelvis to the belly button
Acute appendicitis has no special precautions and
it is important to maintain regular lifestyle and
proper eating habits. Also, the only treatment is
surgery, so don’t overlook the initial symptoms of
sense on abdomen distension, nauseam etc. and
make sure that your right lower abdomen
doesn’t get sick for a day. It’s important to visit
the hospital for early detection and treatment.
Large intestine
Vermiform appendix
Appendix
Small intestine
Hyperplasia of
lymphocytes around
appendix
Hard stool that clogs
the entrance
Other foreign
substances,
inflammatory stenosis,
parasites, tumors, etc.