safety winged blood collection needle

2
To Order: 1.800.772-4346 8:00am–8:30pm (et) Fax: 1.800.329.9109 24 Hrs. www.henryschein.com/medical Discover our range of safety ‘butterfly’ needles for blood collection. Each device features a simple safety mechanism that should be activated immediately after blood withdrawal is complete, thereby reducing the risk of needlestick injury. Thin walled needle minimizes patient discomfort • Flexible wings comfortably secure device to patient’s skin DEHP-free tubing is soft, flexible and kink-resistant Transparent design allows for clear visualization of blood flow • Sterile and single-use Simple, intuitive safety system minimizes risk of needlestick injury: Product list Item # Description 570-0733 570-0734 570-0735 21 G x 3/4 x 12” 23 G x 3/4 x 12” 25 G x 3/4 x 12” Safety Winged Blood Collection Needle Three simple ways to activate safety mechanism – using either one or two handed technique Audible click tells you when the needle is safely locked within the safety shield Safety Winged Blood Collection Needle

Upload: others

Post on 21-May-2022

1 views

Category:

Documents


0 download

TRANSCRIPT

Page 1: Safety Winged Blood Collection Needle

To Order: 1.800.772-4346 8:00am–8:30pm (et) • Fax: 1.800.329.9109 24 Hrs. • www.henryschein.com/medical

Discover our range of safety ‘butterfly’ needles for blood collection. Each device features a simple safety mechanism that should be activated immediately after blood withdrawal is complete, thereby reducing the risk of needlestick injury.

• Thin walled needle minimizes patient discomfort

• Flexible wings comfortably secure device to patient’s skin

• DEHP-free tubing is soft, flexible and kink-resistant

• Transparent design allows for clear visualization of blood flow

• Sterile and single-use

Simple, intuitive safety system minimizes risk of needlestick injury:

Product list

Item # Description

570-0733570-0734570-0735

21 G x 3/4 x 12”23 G x 3/4 x 12”25 G x 3/4 x 12”

Safety Winged Blood Collection Needle

Three simple ways to activate safety mechanism – using either one or two handed technique

Audible click tells you when the needleis safely locked within the safety shield

Safety Winged Blood Collection Needle

Page 2: Safety Winged Blood Collection Needle

Safety Winged Blood Collection Needle

To Order: 1.800.772-4346 8:00am–8:30pm (et) • Fax: 1.800.329.9109 24 Hrs. • www.henryschein.com/medical

You have a choice of three ways to activate the safety mechanism, depending on your preference (either single or two-handed) and/or the position of the needle:

Hold the tubing steady with your third, fourth and fifth fingers against your palm, and use your thumb and index finger to push the safety shield forward until you hear a click.

Two-handed activationOption A:Hold the safety shield steady with your thumb and index finger and use your other hand to pull the tubing back until you hear a click.

Two-handed activationOption B:Hold the wing between the thumb and index finger of one hand and use the other hand to push the safety shield forward until you hear a click.

1 2 3

One-handed activation

Thin-walled needle

Flexible, color-coded wings

Translucent hub

Sliding safety shield with audible click

Rubber sheathed needle

Luer Lock Connection

Soft, clear, kink-resistant, DEHP-free tubing