safeutions sol logy ng inspiri techno -...

36
IN SPI R ING T EC H N OLO G Y SO L U T IONS SAF E CHENNAI SALES OFFICE New No. 25, Old No. 26 Rama Street, Nungambakkam Chennai 600034 Tamil Nadu, India Tel: +91 44 4310 0051 Email: [email protected] BENGALURU SALES OFFICE No. 23rd, 2nd Floor Ace Space Building 8th Main Road, Vasanthnagar Bengaluru 560052 Karnataka, India Tel: +91 80 4169 7781 Email: [email protected] MUMBAI SALES OFFICE 1404, 14th Floor Haware Infotech Park, Sector 30A Vashi, Navi Mumbai 400703 Maharashtra, India Tel: +91 98217 91676 Email: [email protected] DELHI SALES OFFICE B 39, 1st Floor, DDA Shade Okhla Industrial Area, Phase 2 New Delhi 110020, India Email: [email protected] FACTORY ADDRESS 22/A, Swastik Industrial Estate Sari, Sanand Taluka Ahmedabad 382220 Gujarat, India Tel: +91 92 2800 1427/29 Email: [email protected]

Upload: vudan

Post on 28-Apr-2018

216 views

Category:

Documents


2 download

TRANSCRIPT

Page 1: SAFEUTIONS SOL LOGY NG INSPIRI TECHNO - Alfaductalfaduct.com/wp-content/.../2017/12/Alfaduct-Brochure-web-lowres.pdf · The product is designed to comply with the international standard

INSPIRING

TECHNOLOGYSOLUTIONSSAFE

CHENNAI SALES OFFICENew No. 25, Old No. 26Rama Street, Nungambakkam Chennai 600034 Tamil Nadu, IndiaTel: +91 44 4310 0051Email: [email protected]

BENGALURU SALES OFFICENo. 23rd, 2nd FloorAce Space Building8th Main Road, Vasanthnagar Bengaluru 560052 Karnataka, IndiaTel: +91 80 4169 7781Email: [email protected]

MUMBAI SALES OFFICE1404, 14th FloorHaware Infotech Park, Sector 30AVashi, Navi Mumbai 400703 Maharashtra, IndiaTel: +91 98217 91676Email: [email protected]

DELHI SALES OFFICEB 39, 1st Floor, DDA ShadeOkhla Industrial Area, Phase 2New Delhi 110020, India Email: [email protected]

FACTORY ADDRESS22/A, Swastik Industrial EstateSari, Sanand Taluka Ahmedabad 382220 Gujarat, IndiaTel: +91 92 2800 1427/29Email: [email protected]

Page 2: SAFEUTIONS SOL LOGY NG INSPIRI TECHNO - Alfaductalfaduct.com/wp-content/.../2017/12/Alfaduct-Brochure-web-lowres.pdf · The product is designed to comply with the international standard

Generating electricity is one challenge, the other is to have it efficiently and safely transported to the utility point.

ALFADUCT

Page 3: SAFEUTIONS SOL LOGY NG INSPIRI TECHNO - Alfaductalfaduct.com/wp-content/.../2017/12/Alfaduct-Brochure-web-lowres.pdf · The product is designed to comply with the international standard

A multinational powerhouse of over 2,500 employees, ARJ Holding today is one of UAE’s prominent business houses, in the construction sector serving government entities and large corporates. The Group aims to be the leader in GCC and beyond with four major focus areas – Trade, Power, Life & Green encompassing a varied portfolio that includes Building and Engineering Services, Manufacturing, Water Management Technologies, Property Development, Renewable Energy Systems, Hospitality, F&B, Health & Wellness, Marketing Communications, Education, Fashion & Retail.

Headquartered in Dubai, UAE and with offices in 20 markets across 5 countries – Lebanon, Oman, Saudi Arabia, Kuwait and India – ARJ Holding is growing from strength to strength, delivering consistent quality and setting new standards in excellence.

ARJ HOLDINGFrom harnessing water and electric power to transforming lives, ARJ Holding has been a name to reckon with since 1964. Reflecting the values of the Group’s founder, ARJ Holding believes quality, social responsibility and transparency are the guiding principles for seeking new opportunities together, conducting fair business and succeeding together. Coming a long way since its inception, the Group has successfully scaled up its operations and scope in the last decades to diversify and expand beyond the region.

Page 4: SAFEUTIONS SOL LOGY NG INSPIRI TECHNO - Alfaductalfaduct.com/wp-content/.../2017/12/Alfaduct-Brochure-web-lowres.pdf · The product is designed to comply with the international standard

Upholding adherence to highest quality and aligned to the Group’s value of integrity, ALFA Technologies Pvt. Ltd., a subsidiary of ARJ Holding, is a specialized and dedicated company serving the power distribution market through its ALFADUCT—Busbar Trunking System.

In our goal to be distinctive in the service we provide, we commit to stay with the client along the entire process until the full functioning of Busbar Trunking Systems. Our professional and technical assistance spans across every activity ranging from site survey, design & routing drawing preparation, supply & installation to testing, commissioning and maintenance.

ALFADUCT INTRODUCTION

Page 5: SAFEUTIONS SOL LOGY NG INSPIRI TECHNO - Alfaductalfaduct.com/wp-content/.../2017/12/Alfaduct-Brochure-web-lowres.pdf · The product is designed to comply with the international standard

Our product range includes Sandwich, Compact Air Insulated & Lighting Trunking solutions to cater to a wide range of clients from residential blocks to industrial units, facilitated by service that includes:

• Project evaluation and support, design optimization and engineering layout• Customised manufacture & supply• System installation with the best engineering practices• System testing and commissioning• Refurbishment, maintenance and support in layout changes

With direct offices located in Mumbai, Delhi, Bengaluru and Chennai and manufacturing facility located in Gujarat, we are always close to our clients.

SPECIFICATIONS The product is designed to comply with the international standard of IEC 61439-1&6, “specification for low voltage and control gear assemblies”, a particular requirement for busbar trunking systems and IS 8623/1993 Part (1) & (2) Low-voltage Switchgear and Control gear Assemblies.

Copper or Aluminium1.6 mm or 2.0 mm GI400 A to 5000 AAll types of elements to meet site requirements

Copper or Aluminium1.6 mm or 2.0 mm GI200 A to 2000 A

All types of elements to meet site requirements

CopperAluminium25A to 40A

All types of elements to meet site requirements

SOUTHERN RAILWAY HOSPITALMain Power Distribution, Transformers to MV Panels (3 Runs) & DG Synchornization Panel to MV Panel (2 Runs)Consultant—Tebodin Contractor —Kevin Electricals Pvt LtdSandwich Busducts Ratings 4000 A & 1600 A

Conductor:Enclosure: Current ratings:Elements:

Conductor:Enclosure: Current ratings:Elements:

Conductor:Enclosure:Current ratings: Elements:

Sandwich Bus Trunking Systems Compact Air Insulated Bus Trunking Systems

Lighting Bus Trunking Systems

Page 6: SAFEUTIONS SOL LOGY NG INSPIRI TECHNO - Alfaductalfaduct.com/wp-content/.../2017/12/Alfaduct-Brochure-web-lowres.pdf · The product is designed to comply with the international standard

ALFADUCT Busbar Trunking Systems are utilized in building and industrial applications to distribute power to electrical loads safely and efficiently. Due to its many advantages over cabling and conventional bus ducts, Busbar Trunking systems are widely used in commercial and residential buildings, hotels, factories, IT and data center buildings, shopping centers, etc.

Lower impedance and therefore low power loss

Compact size

Moisture ingress and corrosion inhibition

Superior jointing arrangements and no intrusion on conductor

Produced through a proven manufacturing process where all parameters are quality controlled

Certified from a reputed and independent third party

Aesthetically appealing

Higher KA rating for a given enclosure thickness

All through support – Design, installation, testing and commissioning and warranty and after sales

Best and engineered choice of raw materials, controlled production process and robust QA/QC regime ensures that finished product quality is ready to perform trouble free for many years.

BUSBAR OVER CABLES

CABLING SYSTEM REQUIRES INDIVIDUAL CABLES TO BE RUN FOR EACH LOAD CENTER.

ALFADUCT BUS TRUNKING SYSTEM

WHY ALFADUCT IS PREFERRED OVER CABLES?

Better mechanical protection and ingress protection through IP ratings

Eliminates many runs of cabling and is aesthetically appealing

Easy to install and maintain

Saves space and is cost-effective for multi-point power distribution

Conductors can be customized according to voltage drop, harmonics, earthing, etc.

Increased energy savings due to reduced losses, lesser voltage drop and flexibility in repositioning load centers using tap-off points

Easy fault identification and modular installation ensures low replacement costs and lesser down time

Higher KA rating

Fire propagation is eliminated due to nature of construction

WHY ALFADUCT IS PREFERRED OVER CONVENTIONAL BUS DUCTS?

Load Center 1

2

3

4

5

6

7

Load Center 1

2

3

4

5

6

7

END CAP

END FEED UNIT

JOINT PACK

TAP OFF BOX

PLUG IN POINT

VERTICALSPRINGHANGER

PLUG IN FEEDER

VERTICALFIX HANGER

P3

P2

P1

Page 7: SAFEUTIONS SOL LOGY NG INSPIRI TECHNO - Alfaductalfaduct.com/wp-content/.../2017/12/Alfaduct-Brochure-web-lowres.pdf · The product is designed to comply with the international standard

STRENGTH OFSUPPORT HANGERS

spring constant

Proper design of a bus trunking system necessitates a thorough understanding and application of metallurgy & strength of materials, set of physical phenomena associated with the presence and flow of electricity, mechanical forces acting on the system, thermal calculations and general working conditions where this system is applied.

Compliance to International codes which defines the generic and particular test conditions, compliance to local regulation, site conditions study and customization and a quality installation play vital roles in ensuring that the bus trunking system functions as per the design intent.

ALFADUCT products have been developed from very strong engineering fundamentals factoring all the perceivable electrical and mechanical equations to ensure that nothing is left unaddressed. Applying stringent parameters to raw materials used during manufacturing ensures that the finished product performs satisfactorily over its years of service life.

The validation of the design is done through an independent third party laboratory and ALFADUCT has passed stringent type test as per IEC 61439.

DESIGN ANDMANUFACTURING QUALITY

Page 8: SAFEUTIONS SOL LOGY NG INSPIRI TECHNO - Alfaductalfaduct.com/wp-content/.../2017/12/Alfaduct-Brochure-web-lowres.pdf · The product is designed to comply with the international standard

ALL RIVETED CONSTRUCTION (steel alloy, self piercing type) ensures very high shear strength capable of withstanding very high electro dynamic forces, in addition to facilitating anti-rusting and reduced moisture ingress.

CLASS F PET INSULATION, Break Down Voltage (BDV) of 40 KV with superior Di electric strength, higher heat dissipation ability, resistance to chemicals and alkali, high glass transition temperature and therefore high service temperature, heat aging and service life, much less hygroscopic, high tensile strength in comparison to either Epoxy insulation or a normal PE type insulation. Material of Insulation comply to UL Flame rating UL94 & Halogen free

TEMPERATURE RISE indicators on all joint packs for easy monitoring

TAP-OFF BOX loaded on to the main bus duct eliminates load on the contact terminals

MECHANICAL AND ELECTRICAL interlock protection-earth bar making and breaking contact first

ALUMINUM-FINNED SIDE PLATES increase heat transfer area by 30%

MATERIAL & CONSTRUCTION

Page 9: SAFEUTIONS SOL LOGY NG INSPIRI TECHNO - Alfaductalfaduct.com/wp-content/.../2017/12/Alfaduct-Brochure-web-lowres.pdf · The product is designed to comply with the international standard

Standard FeederPlug in FeederEdgewise ElbowFlatwise ElbowEdgewise Offset ElbowFlatwise Offset ElbowCombination ElbowsFlatwise TeePhase Cross over UnitExpansion UnitReducer UnitEnd Feed UnitCenter Feed UnitsPanel Flanges & ConnectionsPanel Flanges with Edgewise Elbow

Panel Flange with Flatwise ElbowPanel Flange with Edge & Flatwise ElbowPanel Flange with Flat & Flatwise ElbowAdapter BoxesRubber BellowsEnd CapFlexible ConnectionsVertical Spring HangerVertical Rigid HangerJoint PackTap off Units

SANDWICH BUS TRUNKING SYSTEM Ratings and Specifications

Page 10: SAFEUTIONS SOL LOGY NG INSPIRI TECHNO - Alfaductalfaduct.com/wp-content/.../2017/12/Alfaduct-Brochure-web-lowres.pdf · The product is designed to comply with the international standard

TECHNICAL DATA TABLE - COPPER

CURRENT RATING

RATING 630A 800A 1000A 1250A 1600A 2000A 2500A 3200A 4000A 5000A

Product Code ADSC063 ADSC080 ADSC100 ADSC125 ADSC160 ADSC200 ADSC250 ADSC320 ADSC400 ADSC500

Rated Insulation Voltage (Ui) 1000 V, AC

Rated Operational Voltage (Ue) Upto 1000 V, AC

Rated Dielectric Voltage 3.5 KV rms for 60 Secs.

Rated Impulse Withstand Voltage 4.4 KV, AC

Rated Frequency 50/60 Hz

Housing Material 1.6 mm GI Housing with Epoxy polyester powder coated (RAL 7032)

RATING SHORT TIME WITHSTAND CURRENT

1 Second (KA) 50 65 65 80 90 100 100 120 120 150

Peak Value (KA) 104 141 141 165 195 216 216 264 325 325

CONDUCTOR DIMENSION & CONFIGURATION

CONDUCTOR C.S.A (mm²) COPPER (PHASE)

Bus bar Dimension 40 x 6 50 x 6 70 x 6 100 x 6 125 x 6 175 x 6 200 x 6 125 x 6 (2) 175 x 6 (2) 200 x 6 (2)

Cross Sectional Area 240 300 420 600 750 1050 1200 1500 2100 2400

Height (h) in mm 77 87 107 137 162 212 237 330 430 480

No. of stack Single Double

IP Rating IP 54 / IP 55 / IP 65

APPROXIMATE WEIGHT OF BUS TRUNKING (Kg / Mtr)

3 Phase + Integral Earth 14 15 19 25 29 38 43 58 77 86

3 Phase + 50% Internal Earth 15 17 21 27 32 43 48 65 86 97

3 Phase + 100% Neutral + Integral Earth 16 18 23 30 36 48 54 72 95 107

3 Phase + 100% Neutral + 50% Internal Earth 17 19 25 33 39 52 59 78 105 118

3 Phase + 200% Neutral + Integral Earth 18 21 27 36 42 57 64 85 114 129

3 Phase + 200% Neutral + 50% Integral Earth 19 22 28 38 46 62 70 92 123 139

3 Phase + 100% neutral + 100% Isolated Earth 18 21 27 36 42 57 64 85 114 129

ELECTRICAL PARAMETERS @50 HZ

RESISTANCE (mΩ/Mtr)

AC Resistance @ 20 C (R) 0.0740 0.0592 0.0427 0.0311 0.0249 0.0179 0.0157 0.0124 0.0090 0.0078

AC Resistance @ thermal conditions (R) 0.0959 0.0767 0.0553 0.0403 0.0322 0.0232 0.0203 0.0161 0.0116 0.0102

REACTANCE (mΩ/Mtr)

Reactance (X) 0.0417 0.0333 0.0238 0.017 0.0136 0.0109 0.0095 0.0070 0.0055 0.0049

IMPEDANCE (mΩ/Mtr)

Impedance (Z) 0.1045 0.0836 0.0602 0.0437 0.0350 0.0256 0.0224 0.0176 0.0128 0.0113

COMPOSITE VOLTAGE DROP PER METER AT FULL LOAD (mv/Mtr/A)

Voltage drop @ 0.7 P.F (V) 0.1675 0.1339 0.0963 0.0698 0.0558 0.0415 0.0363 0.0281 0.0208 0.0184

Voltage drop @ 0.8 P.F (V) 0.1762 0.1409 0.1014 0.0735 0.0587 0.0435 0.0380 0.0296 0.0218 0.0192

Voltage drop @ 0.9 P.F (V) 0.1809 0.1446 0.1041 0.0756 0.0604 0.0444 0.0388 0.0304 0.0222 0.0196

Voltage drop @ 1.0 P.F (V) 0.1661 0.1328 0.0958 0.0698 0.0558 0.0402 0.0352 0.0279 0.0201 0.0177

ELECTRICAL PARAMETERS @60 HZ

RESISTANCE (mΩ/Mtr)

AC Resistance @ 20 C (R) 0.0742 0.0594 0.0427 0.0313 0.0251 0.0181 0.0159 0.0126 0.0092 0.0080

AC Resistance @ thermal conditions (R) 0.0961 0.0769 0.0553 0.0405 0.0325 0.0235 0.0206 0.0163 0.0119 0.0104

REACTANCE (mΩ/Mtr)

Reactance (X) 0.0500 0.0400 0.0286 0.0204 0.0163 0.0130 0.0114 0.0084 0.0066 0.0059

IMPEDANCE (mΩ/Mtr)

Impedance (Z) 0.1083 0.0867 0.0625 0.0454 0.0363 0.0268 0.0235 0.0184 0.0136 0.0119

COMPOSITE VOLTAGE DROP PER METER AT FULL LOAD (mv/Mtr/A)

Voltage drop @ 0.7 P.F (V) 0.1780 0.1424 0.1026 0.0742 0.0594 0.0445 0.0390 0.0301 0.0225 0.0199

Voltage drop @ 0.8 P.F (V) 0.1851 0.1481 0.1068 0.0773 0.0620 0.0461 0.0404 0.0313 0.0233 0.0205

Voltage drop @ 0.9 P.F (V) 0.1875 0.1500 0.1082 0.0785 0.0629 0.0464 0.0407 0.0317 0.0235 0.0207

Voltage drop @ 1.0 P.F (V) 0.1664 0.1332 0.0963 0.0701 0.0563 0.0407 0.0357 0.0282 0.0206 0.0180

TECHNICAL DATA TABLE - ALUMINIUM

CURRENT RATING

RATING 400A 630A 800A 1000A 1250A 1600A 2000A 2500A 3200A 4000A 5000A

Product Code ADSA040 ADSA063 ADSA080 ADSA100 ADSA125 ADSA160 ADSA200 ADSA250 ADSA320 ADSA400 ADSA500

Rated Insulation Voltage (Ui) 1000 V, AC

Rated Operational Voltage (Ue) Upto 1000V, AC

Rated Dielectric Voltage 3.5 KV rms for 60 secs.

Rated Impulse Withstand Voltage 4.4 KV, AC

Rated Frequency 50/60 Hz

1.6 mm GI Housing with Epoxy polyester powder coated (RAL 7032)

RATING SHORT TIME WITHSTAND CURRENT

1 Second (KA) 25 40 50 65 65 65 100 100 120 150 170

Peak Value (KA) 52 82 104 141 141 141 216 216 264 325 374

CONDUCTOR DIMENSION & CONFIGURATION

CONDUCTOR C.S.A (mm²) ALUMINIUM (PER PHASE)

Bus bar Dimension 40 x 6 60 x 6 80 x 6 100 x 6 125 x 6 175 x 6 200 x 6 150 x 6(2) 175 x 6(2) 200 x 6(2) 175 x 6(3)

Cross Sectional Area 240 360 480 600 750 1050 1200 1800 2100 2400 3150

Height 77 97 117 137 162 212 237 380 430 480 648

No. of stack Single Double Triple

IP Rating IP 54 / IP 55 / IP 65

APPROXIMATE WEIGHT OF BUS TRUNKING (Kg / Mtr)

3 Phase + Integral Earth 9.0 11.0 12.50 14.00 16.00 19.50 21.50 31.50 39.00 42.00 56.50

3 Phase + 50% Internal Earth 9.5 11.50 13.00 15.00 17.00 21.00 23.00 33.50 42.00 46.50 61.00

3 Phase + 100% Neutral + Integral Earth 10.0 12.00 14.00 15.50 18.00 22.50 25.00 35.50 45.00 50.00 65.50

3 Phase + 100% Neutral + 50% Internal Earth 10.50 12.50 14.50 16.50 19.00 24.00 26.50 38.00 48.00 53.00 70.00

3 Phase + 200% Neutral + Integral Earth 11.00 13.00 15.00 17.50 20.00 25.50 28.50 40.00 51.00 56.50 73.00

3 Phase + 200% Neutral + 50% Internal Earth 11.50 13.50 16.00 18.50 21.00 27.00 30.00 42.00 54.00 60.00 78.00

3 Phase + 100% neutral + 100% Isolated Earth 11.00 13.00 15.00 17.50 20.00 25.50 28.50 40.00 51.00 56.50 73.00

ELECTRICAL PARAMETERS @50 HZ

RESISTANCE (MΩ/Mtr)

AC Resistance @ 20 C (R) 0.1198 0.0806 0.0611 0.0503 0.0402 0.02984 0.0254 0.0168 0.0145 0.0127 0.0097

AC Resistance @ thermal conditions (R) 0.1553 0.1046 0.0792 0.0652 0.0522 0.03688 0.0329 0.0217 0.0188 0.0165 0.0125

REACTANCE (MΩ/Mtr)

Reactance (X) 0.0417 0.0278 0.0208 0.0170 0.0136 0.0109 0.0095 0.0064 0.0055 0.0049 0.0038

IMPEDANCE (MΩ/Mtr)

Impedance (Z) 0.1608 0.1082 0.0819 0.0674 0.0539 0.0392 0.0343 0.0227 0.0196 0.0172 0.0131

COMPOSITE VOLTAGE DROP PER METER AT FULL LOAD (Mv/Mtr/A)

Voltage drop @ 0.7 P.F (V) 0.2396 0.1610 0.1216 0.1000 0.0800 0.0590 0.0516 0.0342 0.0296 0.0260 0.0198

Voltage drop @ 0.8 P.F (V) 0.2585 0.1738 0.1314 0.1080 0.0865 0.0634 0.0555 0.0367 0.0318 0.0280 0.0213

Voltage drop @ 0.9 P.F (V) 0.2735 0.1840 0.1391 0.1144 0.0916 0.0668 0.0584 0.0386 0.0294 0.0294 0.0223

Voltage drop @ 1.0 P.F (V) 0.2690 0.1812 0.1372 0.1129 0.0904 0.0651 0.0570 0.0376 0.0286 0.0286 0.0217

ELECTRICAL PARAMETERS @60 HZ

RESISTANCE (MΩ/Mtr)

AC Resistance @ 20 C (R) 0.1200 0.0809 0.0614 0.0506 0.0405 0.0293 0.0257 0.0171 0.0148 0.0130 0.0100

AC Resistance @ thermal conditions (R) 0.1557 0.1050 0.0796 0.0656 0.0526 0.0380 0.0333 0.0221 0.0192 0.0169 0.0129

REACTANCE (MΩ/Mtr)

Reactance (X) 0.0500 0.0333 0.0250 0.0204 0.0163 0.0130 0.0114 0.0077 0.0066 0.0059 0.0046

IMPEDANCE (MΩ/Mtr)

Impedance (Z) 0.01635 0.1101 0.0834 0.0687 0.0551 0.0402 0.0352 0.0234 0.0203 0.0178 0.0137

COMPOSITE VOLTAGE DROP PER METER AT FULL LOAD (Mv/Mtr/A)

Voltage drop @ 0.7 P.F (V) 0.2503 0.1683 0.1273 0.1046 0.0838 0.0621 0.0544 0.0363 0.0314 0.0277 0.0213

Voltage drop @ 0.8 P.F (V) 0.2677 0.1801 0.1363 0.1121 0.0898 0.0662 0.0580 0.0386 0.0335 0.0295 0.0227

Voltage drop @ 0.9 P.F (V) 0.2804 0.1888 0.1429 0.1176 0.0943 0.0690 0.0605 0.0403 0.0349 0.0308 0.0236

Voltage drop @ 1.0 P.F (V) 0.2697 0.1819 0.1379 0.1136 0.0911 0.0658 0.0577 0.0383 0.0333 0.0298 0.0223

Page 11: SAFEUTIONS SOL LOGY NG INSPIRI TECHNO - Alfaductalfaduct.com/wp-content/.../2017/12/Alfaduct-Brochure-web-lowres.pdf · The product is designed to comply with the international standard

BUSDUCT HEIGHT (MM)

RATING (A) 400 630 800 1000 1250 1600 2000 2500 3200 4000 5000

Hs Al 75 95 115 135 160 210 235 - - - -

Cu - 75 85 105 135 160 210 235 - - -

Hd Al - - - - - - - 376 426 476 -

Cu - - - - - - - - 326 426 476

Ht Al - - - - - - - - - - 642

BUSDUCT LENGTH (MM)

MIN MAX

L 500 3000

PLUGIN FEEDER LENGTH (MM)

MIN MAX

L 1200 3000

SS Single Stack

DS Double Stack

TS Triple Stack

Standard Feeder Standard Feeder length can be manufactured up to maximum length of 3000mm and minimum length of 500mm.

Plug in Feeder Feeder lengths with Tap off slots are called Plug in Feeders. Supplied with maximum 6 plug-in points (PIP’s) in a standard 3m Length. Can be run vertically or horizontally, or a combination of both. Rating, Location and Number of plug-in Points can be decided based on the site requirement. NOTE For vertical riser application—maximum 4 PIP’s can be provided & for horizontal application maximum 6 PIP’s can be provided. Plug in point rating range from 32A to 800A.

PLUG-IN POINT

Page 12: SAFEUTIONS SOL LOGY NG INSPIRI TECHNO - Alfaductalfaduct.com/wp-content/.../2017/12/Alfaduct-Brochure-web-lowres.pdf · The product is designed to comply with the international standard

Edgewise Elbow Used for 90° turn in the Busduct routing called Edgewise Left Elbow or Edgewise Right Elbow when busbar route is running on their edges.

Flatwise ElbowUsed for 90° turn in the Busduct routing called Flatwise Up Elbow or Flatwise Down Elbow when the busbar route is running on it’s flat.

STANDARD SIZE (MM)

A 350

B 350

STANDARD SIZE (MM)

STACKA B

MIN MAX MIN MAX

SS 30O 600 300 600

DS 30O 600 300 600

TS 30O 600 300 600

STANDARD SIZE (MM)

STACKA B

MIN MAX MIN MAX

SS 30O 600 300 600

DS 500 600 500 600

TS 600 600 600 600

STANDARD SIZE (MM)

STACK MIN MAX

SS 350 350

DS 500 500

TS 600 600

A

AA

B

B B

A

B

A

B

A

B

NOTE S.S. - SINGLE STACKD.S. - DOUBLE STACKT.S. - TRIPLE STACK

Page 13: SAFEUTIONS SOL LOGY NG INSPIRI TECHNO - Alfaductalfaduct.com/wp-content/.../2017/12/Alfaduct-Brochure-web-lowres.pdf · The product is designed to comply with the international standard

CUSTOM ANGLED EDGEWISE ELBOW

CUSTOM ANGLED FLATWISE ELBOW

STANDARD SIZE (MM)

A 350

B 350

Ø 100 ~ 170

STANDARD SIZE (MM)

A 350

B 350

C 350

MAX & MIN ARM SIZES (MM)

MIN MAX

A 300 600

B 300 600

Ø 100 170

STANDARD SIZE (MM)

A B

SS 350 350

DS 500 500

TS 600 600

Ø 100 ~ 170

MIN & MAX ARM DIMENSIONS (MM)

STACKA B

MIN MAX MIN MAX

SS 30O 600 300 600

DS 500 600 500 600

TS 600 600 600 600MIN & MAX ARM DIMENSIONS (MM)

STACKA B C

MIN MAX MIN MAX MIN MAX

SS 30O 600 300 600 300 600

DS 500 600 500 600 300 600

TS 600 600 600 600 300 600

Ø

Ø

A

A

B

C

A

B

B

A

B

C

Custom Angled Elbow Special angle Elbows can be manufactured in both Edgewise and Flatwise elbows where the angle must be greater than 90° and less than 180°.

Edgewise Offset Elbow Combination of two Edgewise Elbows into one single element.

Page 14: SAFEUTIONS SOL LOGY NG INSPIRI TECHNO - Alfaductalfaduct.com/wp-content/.../2017/12/Alfaduct-Brochure-web-lowres.pdf · The product is designed to comply with the international standard

MIN & MAX ARM DIMENSIONS (MM)

STACKA B C

MIN MAX MIN MAX MIN MAX

SS 30O 600 350 600 300 600

DS 300 600 450 600 450 600

TS 300 600 600 600 600 600

STANDARD SIZE (MM)

A 350

B 350

C 350

A

B

CA

B

C

A

B

C

A

B

C

A

B

C

Combination ElbowsCombination Elbows are formed by combining Edgewise and Flatwise Elbows in different combinations to form one element to suit routing requirements.

STANDARD SIZE (MM)

STACK A B C

SS 350 350 350

DS 600 500 600

TS 600 650 600

MIN & MAX ARM DIMENSIONS (MM)

STACKA B C

MIN MAX MIN MAX MIN MAX

SS 30O 600 300 600 300 600

DS 550 600 500 650 550 600

TS 600 600 600 650 600 600

Flatwise Offset ElbowCombination of two Flatwise Elbows into one single element.

Flatwise TeeFlatwise Tee element is required when a branch has to be extended in a direction perpendicular to the existing feeder run. Useful when small power has to be supplied to different parts of the same building.

Phase Cross Over UnitPhase cross over units are used to change the phase orientation as required.

STANDARD SIZE (MM)

A 800

B 400

MAX & MIN ARM SIZES (MM)

MIN MAX

A 800 1000

B 400 500

A

B

1500 MM

Page 15: SAFEUTIONS SOL LOGY NG INSPIRI TECHNO - Alfaductalfaduct.com/wp-content/.../2017/12/Alfaduct-Brochure-web-lowres.pdf · The product is designed to comply with the international standard

Expansion UnitExpansion Units are used at building expansion joints. Also recommended at every 40m interval of a long single stretch Busduct route.

Reducer UnitReducer units are used whenever a reduction in Ampere rating of Busduct is required along the Busduct Routing. Can be provided with an isolating or switching device

1200 MM

1500 MM

DIMENSIONS (MM)

RATINGA D W H

MIN MAX

400 350 500 350 400 800

630 350 500 400 400 800

800 350 500 400 400 800

1000 350 500 450 450 800

1250 350 500 500 500 1000

1600 350 500 500 500 1000

W

H

DIRECT TYPE (WITHOUT ISOLATOR)

A

D

W

H

WITH ISOLATOR TYPE

A

D

End Feed UnitEnd Feed units are usually used at the bottom of the vertical Raiser which are fed by cables. Two options available Direct type (W/O Isolator) or Isolator type.

Page 16: SAFEUTIONS SOL LOGY NG INSPIRI TECHNO - Alfaductalfaduct.com/wp-content/.../2017/12/Alfaduct-Brochure-web-lowres.pdf · The product is designed to comply with the international standard

DIRECT TYPE (WITHOUT ISOLATOR)

WITH ISOLATOR TYPE

DIMENSIONS (MM)

RATINGA D W H

MIN MAX

400 350 600 350 350 850

630 350 600 350 400 850

800 350 600 350 400 850

1000 350 600 400 400 1000

1250 350 600 400 450 1000

1600 350 600 500 500 1000

A

AH

HW

W

D

D

A

A

Center Feed Units Center feed units are used in the middle of a Busduct run & used for feeding power through cable. Can be supplied with or without switchgear unit.

Panel Flanges & ConnectionsPanel Flanges are used for direct connection with Switchgear panels & Transformers.

Page 17: SAFEUTIONS SOL LOGY NG INSPIRI TECHNO - Alfaductalfaduct.com/wp-content/.../2017/12/Alfaduct-Brochure-web-lowres.pdf · The product is designed to comply with the international standard

DIMENSIONS (MM)

STACK RATINGA

Al Cu

ss

400 40 -

630 60 40

800 80 50

1000 100 70

1250 125 100

1600 175 125

2000 200 175

2500 - 200

FIGURE 4 DIMENSIONS (MM)

DS

2500 150 -

100 175 500

4000 200 175

5000 - 200

FIGURE 5 DIMENSIONS (MM)

STACK RATINGA

Al Cu

TS 5000 175 -

Page 18: SAFEUTIONS SOL LOGY NG INSPIRI TECHNO - Alfaductalfaduct.com/wp-content/.../2017/12/Alfaduct-Brochure-web-lowres.pdf · The product is designed to comply with the international standard

Panel Flanges with Edgewise Elbow

Panel Flanges with Flatwise Elbow

DIMENSIONS (MM)

STACK

STANDARD MAX & MIN DIMENSIONS

A BA B

MIN MAX MIN MAX

SS 350 350 300 600 300 600

DS 350 350 300 600 300 600

TS 350 350 300 600 300 600

DIMENSIONS (MM)

STACK

STANDARD MAX & MIN DIMENSIONS

A BA B

MIN MAX MIN MAX

SS 350 350 300 600 300 600

DS 500 500 500 600 500 600

TS 600 600 600 600 600 600

B

A

B

A

B

A

B

A

Panel Flange with Edge & Flatwise Elbow

Panel Flange with Flat & Flatwise Elbow

DIMENSIONS (MM)

STACK

STANDARD MAX & MIN DIMENSIONS

A B CA B C

MIN MAX MIN MAX MIN MAX

SS 350 350 350 300 600 300 600 300 600

DS 500 500 350 450 600 450 600 300 600

TS 600 600 350 600 600 600 600 300 600

A

A

B

B

CC

AA

B

B

C

C

DIMENSIONS (MM)

STACK

STANDARD MAX & MIN DIMENSIONS

A B CA B C

MIN MAX MIN MAX MIN MAX

SS 350 350 350 300 600 350 600 350 600

DS 350 500 500 300 600 450 600 450 600

TS 350 600 600 300 600 600 600 600 600

Page 19: SAFEUTIONS SOL LOGY NG INSPIRI TECHNO - Alfaductalfaduct.com/wp-content/.../2017/12/Alfaduct-Brochure-web-lowres.pdf · The product is designed to comply with the international standard

C

H

Adapter BoxesCustomized housing for Connection between Panel flange terminals and Switchgear / Transformer terminals.

Rubber BellowsRequired to be fixed between DG Adapter box and end flange to avoid impact of vibration from Gensets.

L, W, H—As per site requirement to be specified during design.H

LW

L

W

150

17

0

W

End Cap Used to close the end of a Busduct route. Usually supplied prefitted to the Busduct. W is dependent on Busduct height.

Flexible ConnectionsUsed to connect panel flange terminals to Transformers, Generators, Panel Terminals. Flexibles are available in both Copper & Aluminium

DIMENSIONS

A B C

MIN MAX MIN MAX

AS REQ. 80 100 300 500

Page 20: SAFEUTIONS SOL LOGY NG INSPIRI TECHNO - Alfaductalfaduct.com/wp-content/.../2017/12/Alfaduct-Brochure-web-lowres.pdf · The product is designed to comply with the international standard

Vertical Spring hangerOne set of spring hanger must be fixed at every floor slab crossing.

Vertical Rigid HangerOne Rigid hanger must be fixed at center of every 3m Vertical raiser or one per floor.

Joint Pack• Mono block design to facilitate assembly of joints in

a single block without disturbing the adjacent sections

• Shear of nuts with Belleville washers for proper torque on the joints.

• Temperature rise indication stickers for easy identification of hot spots.

• Imported contact grease for improved contact surface area.

• Aluminum serrated profile for improved heat dissipation.

.S.NO PARAMETER TYPE 1 TYPE 2 TYPE 3 TYPE 4 TYPE 5

1 MCB / Fuse / Socket Provision 16A - 63A NA NA NA NA

2 MCCB + rotary Handle Provision NA 32A - 125A 160A - 200A 250A - 400A 630A

3 SFU Provision

4 Box Dimension (H x W x D)mm X 200 X 400200

X 250 X 500220

X 250 X 550250

X 300 X 600250

X 400 X 900270

5 Recommended Cable size (Alu-max)

25sq.mm 70sq.mm 150sq.mm 300sq.mm 2Rx400Sq.mm

Tap Off Units• Efficiently taps power from main bus trunking system• Enclosure fabricated with 1.6 mm Electro galvanized

steel.• Spring loaded silver plated plug-in contacts• Mechanical & Electrical interlocking mechanism to

prevent accidental opening of the door and prevent plug- out or plug-in to the bus trunking when the device is in ‘ON’ position.

• Suitable external earthing is provided in the tap off box to maintain the earth continuity.

• The live parts inside the tap off box are guarded by transparent visible panel which prevents accidental physical touch.

• The tap off box is designed in a way to accommodate different reputed isolating / tripping devices.

TYPE 1

TYPE 2,3,4 TYPE 5

H

W D

H

WD

Page 21: SAFEUTIONS SOL LOGY NG INSPIRI TECHNO - Alfaductalfaduct.com/wp-content/.../2017/12/Alfaduct-Brochure-web-lowres.pdf · The product is designed to comply with the international standard

Standard FeederPlug in FeederEdgewise ElbowFlatwise ElbowEdgewise Offset ElbowFlatwise Offset ElbowCombination ElbowsFlatwise Tee

COMPACT AIR INSULATED BUS TRUNKING SYSTEMS Ratings and Specifications

Page 22: SAFEUTIONS SOL LOGY NG INSPIRI TECHNO - Alfaductalfaduct.com/wp-content/.../2017/12/Alfaduct-Brochure-web-lowres.pdf · The product is designed to comply with the international standard

TECHNICAL DATA TABLE - COPPER

CURRENT RATING

RATING 315A 400A 500A 630A 800A 1000A 1250A 1750 2000A

Product Code ADAC031 ADAC040 ADAC050 ADAC063 ADAC080 ADAC100 ADAC125 ADAC175 ADAC200

Rated Insulation Voltage (Ui) 1000 V, AC

Rated Operational Voltage (Ue) Upto 1000 V, AC

Rated Dielectric Voltage 3.5 KV rms for 60 Secs.

Rated Impulse Withstand Voltage 4.4 KV, AC

Rated Frequency 50/60 Hz

Housing Material 1.6 mm GI Housing with Epoxy polyester powder coated (RAL 7032)

RATING SHORT TIME WITHSTAND CURRENT

1 Second (KA) 20 30 35 50 50 50 50 65 65

Peak Value (KA) 38 60 72 104 104 104 104 141 141

CONDUCTOR DIMENSION & CONFIGURATION

CONDUCTOR C.S.A (mm²) COPPER (PHASE)

Bus bar Dimension 20 x 6 30 x 6 40 x 6 50 x 6 70 x 6 90 x 6 50 x 6(2) 70 x 6(2) 90 x 6(2)

Cross Sectional Area 120 180 240 300 420 540 600 840 1080

Height (h) in mm 65 75 85 95 115 135 190 230 270

No. of stack Single Double

IP Rating IP 54 / IP 55 / IP 65

APPROXIMATE WEIGHT OF BUS TRUNKING (Kg / Mtr)

3 Phase + Integral Earth 9.6 11.5 13.3 15.2 18.9 22.6 24.0 31.4 38.8

3 Phase + 50% Internal Earth 10.2 12.3 14.4 16.5 20.8 25.0 26.7 35.1 43.6

3 Phase + 100% Neutral + Integral Earth 10.7 13.1 15.5 17.9 22.6 27.4 29.3 38.9 48.4

3 Phase + 100% Neutral + 50% Internal Earth 11.2 13.9 16.5 19.2 24.5 28.3 32.0 42.6 53.2

3 Phase + 200% Neutral + Integral Earth 11.8 14.7 17.6 20.5 26.4 32.2 34.7 46.3 58.0

3 Phase + 200% Neutral + 50% Integral Earth 12.3 15.5 18.7 21.9 28.2 34.6 37.3 50.1 62.8

3 Phase + 100% neutral + 100% Isolated Earth 11.8 14.7 17.6 20.5 26.4 32.2 34.7 46.3 58.0

ELECTRICAL PARAMETERS @50 HZ

RESISTANCE (mΩ/Mtr)

AC Resistance @ 20 C (R) 0.1481 0.0987 0.0740 0.0592 0.0429 0.0339 0.0296 0.0215 0.0169

AC Resistance @ thermal conditions (R) 0.1888 0.1259 0.0944 0.0755 0.0548 0.0432 0.0378 0.0274 0.0216

REACTANCE (mΩ/Mtr)

Reactance (X) 0.1250 0.1056 0.0792 0.0667 0.0524 0.0444 0.0342 0.0268 0.0313

IMPEDANCE (mΩ/Mtr)

Impedance (Z) 0.2264 0.1643 0.1232 0.1007 0.0758 0.062 0.0509 0.0383 0.0313

COMPOSITE VOLTAGE DROP PER METER AT FULL LOAD (mv/Mtr/A)

Voltage drop @ 0.7 P.F (V) 0.3826 0.2825 0.2118 0.1736 0.1309 0.107 0.0879 0.0662 0.0541

Voltage drop @ 0.8 P.F (V) 0.3915 0.2842 0.2131 0.1739 0.1304 0.106 0.0878 0.0658 0.0535

Voltage drop @ 0.9 P.F (V) 0.3885 0.2758 0.2068 0.1679 0.1249 0.1008 0.0847 0.0629 0.0508

Voltage drop @ 1.0 P.F (V) 0.327 0.2181 0.1635 0.1308 0.0949 0.0748 0.0655 0.0475 0.0374

ELECTRICAL PARAMETERS @60 HZ

RESISTANCE (mΩ/Mtr)

AC Resistance @ 20 C (R) 0.1483 0.0989 0.0742 0.0594 0.0431 0.0341 0.0298 0.0127 0.0171

AC Resistance @ thermal conditions (R) 0.192 0.1281 0.0961 0.0769 0.0558 0.0441 0.0386 0.028 0.0222

REACTANCE (mΩ/Mtr)

Reactance (X) 0.1500 0.1267 0.095 0.08 0.0629 0.0533 0.041 0.0321 0.0272

IMPEDANCE (mΩ/Mtr)

Impedance (Z) 0.2436 0.1801 0.1351 0.111 0.0841 0.0692 0.0563 0.0437 0.0351

COMPOSITE VOLTAGE DROP PER METER AT FULL LOAD (mv/Mtr/A)

Voltage drop @ 0.7 P.F (V) 0.4172 0.3111 0.2333 0.1916 0.145 0.119 0.0972 0.0734 0.0604

Voltage drop @ 0.8 P.F (V) 0.4219 0.3092 0.2319 0.1897 0.1427 0.1165 0.0961 0.0722 0.059

Voltage drop @ 0.9 P.F (V) 0.4123 0.2951 0.2214 0.1801 0.1344 0.1089 0.0911 0.0678 0.0551

Voltage drop @ 1.0 P.F (V) 0.3325 0.2219 0.1664 0.1332 0.0966 0.0764 0.0669 0.0485 0.0385

TECHNICAL DATA TABLE - ALUMINIUM

CURRENT RATING

RATING 200A 250A 315A 400A 500A 630A 800A 1000A 1250A

Product Code ADAA020 ADAA025 ADAA031 ADAA040 ADAA050 ADAA063 ADAA080 ADAA100 ADAA125

Rated Insulation Voltage (Ui) 1000 V, AC

Rated Operational Voltage (Ue) Upto 1000V, AC

Rated Dielectric Voltage 3.5 KV rms for 60 secs.

Rated Impulse Withstand Voltage 4.4 KV, AC

Rated Frequency 50/60 Hz

Housing Material 1.6 mm GI Housing with Epoxy polyester powder coated (RAL 7032)

RATING SHORT TIME WITHSTAND CURRENT

1 Second (KA) 10 15 25 30 35 50 50 50 50

Peak Value (KA) 16 28 50 60 72 104 104 104 104

CONDUCTOR DIMENSION & CONFIGURATION

CONDUCTOR C.S.A (mm²) COPPER (PER PHASE)

Bus bar Dimension 20 x 6 30 x 6 40 x 6 50 x 6 70 x 6 90 x 6 50 x 6(2) 70 x 6(2) 90 x 6(2)

Cross Sectional Area 120 180 240 300 420 540 600 840 1080

Height 65 75 85 95 115 135 190 230 270

No. of stack Single Double

IP Rating IP 54 / IP 55 / IP 65

APPROXIMATE WEIGHT OF BUS TRUNKING (Kg / Mtr)

3 Phase + Integral Earth 7.4 8.2 8.9 9.7 11.2 12.7 13.5 16.5 19.6

3 Phase + 50% Internal Earth 7.6 8.4 9.3 10.1 11.8 13.5 14.4 17.7 21.1

3 Phase + 100% Neutral + Integral Earth 7.8 8.7 9.6 10.5 12.4 14.2 15.2 18.9 22.6

3 Phase + 100% Neutral + 50% Internal Earth 7.9 8.9 10.0 11.0 13.0 15.0 16.0 20.1 24.1

3 Phase + 200% Neutral + Integral Earth 8.1 9.2 10.3 11.4 13.6 15.7 16.9 21.3 25.6

3 Phase + 200% Neutral + 50% Internal Earth 8.3 9.5 10.6 11.8 14.2 16.5 17.7 22.4 27.1

3 Phase + 100% neutral + 100% Isolated Earth 8.1 9.2 10.3 11.4 13.6 15.7 16.9 21.3 25.6

ELECTRICAL PARAMETERS @50 HZ

RESISTANCE (MΩ/Mtr)

AC Resistance @ 20 C (R) 0.2611 0.1741 0.1305 0.1044 0.0757 0.0598 0.0522 0.0379 0.0299

AC Resistance @ thermal conditions (Rᵼ) 0.3335 0.2223 0.1667 0.1334 0.0967 0.0763 0.0667 0.0484 0.0382

REACTANCE (MΩ/Mtr)

Reactance (X) 0.125 0.1056 0.0792 0.0667 0.0524 0.0444 0.0342 0.0268 0.0227

IMPEDANCE (MΩ/Mtr)

Impedance (Z) 0.3561 0.2461 0.1846 0.1491 0.1100 0.0883 0.0749 0.0553 0.0444

COMPOSITE VOLTAGE DROP PER METER AT FULL LOAD (Mv/Mtr/A)

Voltage drop @ 0.7 P.F (ᵼV) 0.5581 0.3994 0.2995 0.2438 0.1817 0.1471 0.1229 0.0916 0.0742

Voltage drop @ 0.8 P.F (ᵼV) 0.5920 0.4178 0.3133 0.2542 0.1884 0.1519 0.1280 0.0949 0.0765

Voltage drop @ 0.9 P.F (ᵼV) 0.6140 0.4261 0.3195 0.2582 0.1902 0.1524 0.1297 0.0956 0.0766

Voltage drop @ 1.0 P.F (ᵼV) 0.5776 0.3850 0.2887 0.2310 0.1675 0.1322 0.1155 0.0838 0.0662

ELECTRICAL PARAMETERS @60 HZ

RESISTANCE (MΩ/Mtr)

AC Resistance @ 20ᵼ C (Rᵼᵼ) 0.2614 0.1744 0.1309 0.1047 0.0760 0.0601 0.0525 0.0382 0.0302

AC Resistance @ thermal conditions (Rᵼ) 0.3390 0.2262 0.1697 0.1359 0.0986 0.0779 0.0681 0.0495 0.0392

REACTANCE (MΩ/Mtr)

Reactance (X) 0.1500 0.1267 0.0950 0.0800 0.0629 0.0533 0.0410 0.0321 0.0272

IMPEDANCE (MΩ/Mtr)

Impedance (Z) 0.3707 0.2592 0.1945 0.1577 0.1169 0.0944 0.0795 0.0590 0.0477

COMPOSITE VOLTAGE DROP PER METER AT FULL LOAD (Mv/Mtr/A)

Voltage drop @ 0.7 P.F (ᵼV) 0.5955 0.4301 0.3226 0.2631 0.1969 0.1600 0.1330 0.0995 0.0810

Voltage drop @ 0.8 P.F (ᵼV) 0.6256 0.4451 0.3339 0.2714 0.2020 0.1633 0.1370 0.1019 0.0826

Voltage drop @ 0.9 P.F (ᵼV) 0.6414 0.4481 0.3361 0.2721 0.2011 0.1616 0.1371 0.1013 0.0816

Voltage drop @ 1.0 P.F (ᵼV) 0.5871 0.3918 0.2939 0.2354 0.1708 0.1349 0.1179 0.0857 0.0679

Page 23: SAFEUTIONS SOL LOGY NG INSPIRI TECHNO - Alfaductalfaduct.com/wp-content/.../2017/12/Alfaduct-Brochure-web-lowres.pdf · The product is designed to comply with the international standard

BUSDUCT HEIGHT (MM)

RATING (A) 200 250 315 400 500 630 800 1000 1250 1750 2000

Single Stack

Al 65 75 85 95 115 135 - - - - -

Cu - - 65 75 85 95 115 135 - - -

Double Stack

Al - - - - - - 190 230 270 - -

Cu - - - - - - - - 190 230 270

BUSDUCT LENGTH (MM)

MIN MAX

L 500 3000

PLUGIN FEEDER LENGTH (MM)

MIN MAX

L 1200 3000

Standard Feeder Standard Feeder length can be manufactured up to maximum length of 3000mm and minimum length of 500mm.

Plug in Feeder Feeder lengths with Tap off slots are called Plug in Feeders. Supplied with maximum 6 plug-in points (PIP’s) in a standard 3m Length. Can be run vertically or horizontally, or a combination of both. Rating, Location and number of plug-in points can be decided based on the site requirement. NOTE For vertical riser application—maximum 4 PIP’s can be provided & for horizontal application maximum 6 PIP’s can be provided. Plug in point rating ranges from 32A to 800A.

PLUG-IN POINT

PLUG-IN POINT

PLUG-IN POINT

Page 24: SAFEUTIONS SOL LOGY NG INSPIRI TECHNO - Alfaductalfaduct.com/wp-content/.../2017/12/Alfaduct-Brochure-web-lowres.pdf · The product is designed to comply with the international standard

Edgewise Elbow Used for 90° turn in the Busduct routing called Edgewise Left Elbow or Edgewise Right Elbow when busbar route is running on their edges.

Flatwise Elbow Used for 90° turn in the Busduct routing called Edgewise Left Elbow or Edgewise Right Elbow when busbar route is running on their edges.

Edgewise Offset ElbowEdgewise offset Elbow is combination of two Edgewise Elbows into one single element.

Flatwise Offset ElbowFlatwise offset Elbow is a combination of two Flatwise elbows into one single element.

Combination ElbowsCombination Elbows are formed by combining Edgewise and Flatwise Elbows in different combinations to form one element to suit routing requirements.

Flatwise TeeFlatwise Tee element is required when a branch has to be extended in a direction perpendicular to the existing feeder run. Useful when small power has to be supplied to different parts of the same building.

STANDARD SIZE (MM)

A 350

B 350

STANDARD SIZE (MM)

STACK A B

SS 350 350

DS 500 500

STANDARD SIZE (MM)

A 800

B 400

STANDARD SIZE (MM)

STACK MIN MAX

SS 800 1000

DS 400 500

STANDARD SIZE (MM)

STACK A B C

SS 350 350 350

DS 400 350 400

MIN & MAX ARM DIMENSIONS (MM)

STACKA B

MIN MAX MIN MAX

SS 30O 600 300 600

DS 35O 600 350 600

STANDARD SIZE (MM)

A 350

B 500

C 600

NOTE S.S. - SINGLE STACKD.S. - DOUBLE STACKT.S. - TRIPLE STACK

MIN & MAX ARM DIMENSIONS (MM)

STACKA B

MIN MAX MIN MAX

SS 30O 600 300 600

DS 30O 600 300 600

MIN & MAX ARM DIMENSIONS (MM)

STACKA B C

MIN MAX MIN MAX MIN MAX

SS 30O 600 300 600 300 600

DS 400 600 350 650 400 600

STANDARD SIZE (MM)

STACKA B C

MIN MAX MIN MAX MIN MAX

SS 30O 600 300 600 300 600

DS 300 600 300 600 300 600

TS 300 600 300 600 300 600

Page 25: SAFEUTIONS SOL LOGY NG INSPIRI TECHNO - Alfaductalfaduct.com/wp-content/.../2017/12/Alfaduct-Brochure-web-lowres.pdf · The product is designed to comply with the international standard

Plug in Feeder UnitEnd feed unit & End CapFlexible ElbowFlexible BracketTap off Unit

LIGHTING TRUNKING SYSTEMS Ratings and Specifications

Page 26: SAFEUTIONS SOL LOGY NG INSPIRI TECHNO - Alfaductalfaduct.com/wp-content/.../2017/12/Alfaduct-Brochure-web-lowres.pdf · The product is designed to comply with the international standard

TECHNICAL DATA TABLE - COPPER

CURRENT RATING

Parameter/Model ADLT2511 ADLT4011 ADLT2531 ADLT4031 ADLT2512 ADLT4012 ADLT2532 ADLT4032

Rated current ( 35 Deg C ) A 25 40 25 40 25 40 25 40

Rated peak withstand current KA 4.4 4.4 9.6 9.6 4.4 4.4 9.6 9.6

Rated Insulation Voltage V 690 690 690 690 690 690 690 690

Rated Operational Voltage V 220 220 415 415 220 220 415 415

Rated Impulse Voltage kV 4 4 4 4 4 4 4 4

Frequency Hz 50 50 50 50 50 50 50 50

Conductor Material Copper

Phase/Neutral/ Earth configuration

Protection IP 55 IP 55 IP 55 IP 55 IP 55 IP 55 IP 55 IP 55

Design standard IEC 60439-2 IEC 60439-2

Conductor resistance @ 20 Deg C 6.8 6.8 2.83 2.83 6.8 6.8 2.83 2.83

Conductor resistance @ 35 Deg C 8.3 8.3 3.46 3.46 8.3 8.3 3.46 3.46

Reactance @ 35 Deg C and 50 Hz 0.02 0.02 0.02 0.02 0.02 0.02 0.02 0.02

Impedence @ 35 Deg C and 50 Hz 8.33 8.33 3.46 3.46 8.33 8.33 3.46 3.46

Body earthing (PE) resistance @ 20 Deg C 1.57 1.57 1.57 1.57 0.8 0.8 0.8 0.8

Fault conditions data

Avg resistance @ 20 Deg C Ph/N (Symmetric loop) µ-Ω/m 27.21 27.21 19.4 19.4 27.21 27.21 17.28 17.28

Avg reactance @ 20 Deg C Ph/N (Symmetric loop) µ-Ω/m 0.85 0.85 0.38 0.38 0.85 0.85 5.25 5.25

Avg Impedence @ 20 Deg C Ph/N (Symmetric loop) µ-Ω/m 27.22 27.22 19.41 19.41 27.22 27.22 18.06 18.06

Avg resistance @ 20 Deg C Ph/PE (Symmetric loop) µ-Ω/m 19.4 19.4 13.83 13.83 17.28 17.28 13.83 13.83

Avg reactance @ 20 Deg C Ph/PE (Symmetric loop) µ-Ω/m 0.38 0.38 0.73 0.73 5.25 5.25 0.73 0.73

Avg Impedance @ 20 Deg C Ph/PE (Symmetric loop) µ-Ω/m 19.41 19.41 13.85 13.85 18.06 18.06 13.85 13.85

Avg resistance @ 20 Deg C Ph/Ph (Reactance mtd) µ-Ω/m 13.61 13.61 5.68 5.68 13.61 13.61 5.58 5.58

Avg resistance @ 20 Deg C Ph/N (Reactance mtd) µ-Ω/m 13.61 13.61 5.68 5.68 13.61 13.61 5.68 5.68

Avg resistance @ 20 Deg C Ph/PE (Reactance mtd) µ-Ω/m 11.01 11.01 7.66 7.66 10.26 10.26 6.92 6.92

Avg resistance @ Rated current Ph/Ph and 35 Deg C. µ-Ω/m 16.6 16.6 6.91 6.91 16.59 16.59 6.92 6.92

Avg resistance @ Rated current Ph/N and 35 Deg C.µ-Ω/m 16.6 16.6 6.91 6.91 16.59 16.59 6.92 6.92

Avg resistance @ Rated current Ph/PE and 35 Deg C. µ-Ω/m 12.5 12.5 8.7 8.7 11.77 11.77 6.92 ?? 6.92 ??

Avg Reactance @ Rated current Ph/Ph and 35 Deg C. µ-Ω/m 0.04 0.04 0.9 0.9 0.35 0.35 0.9 0.9

Avg Reactance @ Rated current Ph/Ph and 35 Deg C. µ-Ω/m 0.04 0.04 0.9 0.9 0.35 0.35 0.9 0.9

Avg Reactance @ Rated current Ph/Ph and 35 Deg C. µ-Ω/m 0.035 0.035 0.035 0.035 0.07 0.07 1.85 1.85

Voltage drop, 50 Hz @ uniform load V / 100 m/A

@ PF 1 0.72 0.3 0.72 0.3

@ PF 0.9 0.67 0.28 0.67 0.28

@ PF 0.8 0.61 0.25 0.61 0.25

@ PF 0.7 0.54 0.22 0.55 0.22

Plug in feeder unitAluminium Alloy enclosure makes it light weight, aesthetic and rust proof.2, 4 or 6 tin plated copper conductors. Feeder units are 2m or 3m in length and have 2 or 3 tap off points.Electrical connection device automatically synchronize contact with each phase Ingress Protection Level IP55Compliant with IEC 60332-3, all insulation & plastic materials are non-halogen and compliant to IEC 60695-2 burning hot wire test.Aluminum routing used as earthing

LEFT TO RIGHT SIDE END FEEDER

RIGHT TO LEFT SIDE END FEEDER

END CAP

Page 27: SAFEUTIONS SOL LOGY NG INSPIRI TECHNO - Alfaductalfaduct.com/wp-content/.../2017/12/Alfaduct-Brochure-web-lowres.pdf · The product is designed to comply with the international standard

Flexible ElbowFlexible Elbows can change directions and bypass obstacles.

Universal Fixing BracketFixing brackets are used to suspend lighting trunking with 6mm threaded rod and also used for fixing luminaries units.

FIXING BRACKETS

LUMINARY UNIT

STRUCTURAL ELEMENT (OBSTACLE)

Tap off unit10A & 16A tap off units can be provided

10A tap off units can be prewired cable, prefabricated connectors, optional phase, can be connected with the switch.

16A tap off units can choose fuse protection, single or three phase.

Can be applied to all series lighting busbar

TAP OFF UNIT

TAP OFF UNIT (10A)

LUMINARY UNIT

Page 28: SAFEUTIONS SOL LOGY NG INSPIRI TECHNO - Alfaductalfaduct.com/wp-content/.../2017/12/Alfaduct-Brochure-web-lowres.pdf · The product is designed to comply with the international standard

CERTIFICATES

Thermographic SurveyThermographic survey can be conducted on the installed busducts to assess the surface temperature of the busbars and at Joints. The survey can be conducted with all components in its normal operating conditions and electrical loads. A report will be submitted to customer consisting of thermographic images of Joints with temperature profiles and readings in relation to the limits specified as per standard and recommendations for preventive maintenance Typical Thermograpic survey Report shown below:

Page 29: SAFEUTIONS SOL LOGY NG INSPIRI TECHNO - Alfaductalfaduct.com/wp-content/.../2017/12/Alfaduct-Brochure-web-lowres.pdf · The product is designed to comply with the international standard

CERTIFICATESCERTIFICATES

Page 30: SAFEUTIONS SOL LOGY NG INSPIRI TECHNO - Alfaductalfaduct.com/wp-content/.../2017/12/Alfaduct-Brochure-web-lowres.pdf · The product is designed to comply with the international standard

MANUFACTURING FACILITY

A well laid out manufacturing facility housing state-of-the-art machinery functioning with smart engineering commands and compatible with modern production processes, gives ALFADUCT an advantageous edge for customized orders and quick deliveries.

Page 31: SAFEUTIONS SOL LOGY NG INSPIRI TECHNO - Alfaductalfaduct.com/wp-content/.../2017/12/Alfaduct-Brochure-web-lowres.pdf · The product is designed to comply with the international standard

OUR PARTNERSCLIENTS

Hindustan Aeronautics Limited

CONSULTANTS

Page 32: SAFEUTIONS SOL LOGY NG INSPIRI TECHNO - Alfaductalfaduct.com/wp-content/.../2017/12/Alfaduct-Brochure-web-lowres.pdf · The product is designed to comply with the international standard

M/s Alfa Technologies Pvt. Ltd. have supplied the ALFADUCT 3200A Sandwich design busbar systems for our project of Hindustan Aeronautics Limited, Bangalore. We are very much satisfied with the product performance.

RAI INDUSTRIAL POWER PVT. LTD.

The ALFADUCT Sandwich Design Busbar Trunking for our IGate Global Solutions Centre in Bangalore has been successfully installed, tested and commissioned and we are very much satisfied with the supply of bus trunking, project execution and service support.

SHANKAR ELECTRICALS

M/s Alfa Technologies Pvt. Ltd. have supplied ALFADUCT Sandwich bus duct of 1250A Aluminium conductor for our project M/s Mando Automotive, Chennai. The Busduct system is working successfully for the last two years. We wish them success.

ARJUNA ENGINEERING PVT. LTD.

This is to inform that M/s Alfa Technologies Pvt. Ltd. has supplied variable Ampere ratings Sandwich design busbar systems for our Project of Tamil Nadu Secretariat at Chennai. We have no hesitation in recommending ALFADUCT products for your suitable use. We also wish them success in their future endeavour.

OFFICE OF THE P.W.D.

M/s ARJ Electromechanical Contracting Pvt. Ltd. have supplied ALFADUCT Sandwich Design Busbar Trunking of 4500A Aluminium conductor for our project M/s Aisin Automotive Karnataka Pvt. Ltd in Karnataka. The same has been successfully installed, tested and commissioned. We wish them success.

THE POWER ENGINEERING CO.

The ALFADUCT Sandwich design busbar was supplied for our project of Tamil Nadu Secretariat at Chennai. We are very much satisfied with the product performance.

M/S P.S.K. ENGINEERING CONSTRUCTION & CO.

We have checked the technical specification of products and we will start specifying the product name in our further projects.

D.R. BERLARE ELECTRICAL AND MEP CONSULTANT

TESTIMONIALSCONTRACTORS

Page 33: SAFEUTIONS SOL LOGY NG INSPIRI TECHNO - Alfaductalfaduct.com/wp-content/.../2017/12/Alfaduct-Brochure-web-lowres.pdf · The product is designed to comply with the international standard

PROJECTS

Client: Puravankara Type: Residential

Client: PWD Type: Government Building

Client: SIDCOType: Commercial

Client: Southern RailwayType: Commercial

Purva Swanlake India

Mando Automotive India

Rippon Building Annexe India

SIDCO India

Southern Railway India

Client: Mando AutomotiveType: Industrial

Client: JBM Sanand Type: Industrial

JBM, Sanand India

Client: I GateType: IT Service

Client: Radisson HotelType: Hotel

Client: Aisin Automotive Type: Industrial

Client: BSA UniversityType: Educational Institution

I Gate India

Radisson Hotel India

BSA University India

Aisin Automotive India

Client: PWDType: Government Building

Secretariat India

Client: RED MallType: Shopping Centre

RED Mall India

Client: MotherplastType: Industrial

Motherplast India

Client: PuravankaraType: Commercial

Purva Gainz India

Client: Tamarai Techpark Type: Commercial

Tamarai Techpark India

Page 34: SAFEUTIONS SOL LOGY NG INSPIRI TECHNO - Alfaductalfaduct.com/wp-content/.../2017/12/Alfaduct-Brochure-web-lowres.pdf · The product is designed to comply with the international standard

PROJECTS DETAILS

Page 35: SAFEUTIONS SOL LOGY NG INSPIRI TECHNO - Alfaductalfaduct.com/wp-content/.../2017/12/Alfaduct-Brochure-web-lowres.pdf · The product is designed to comply with the international standard

Committed to a continued alliance with our clients, our services extend beyond sales to address your queries and concerns. Our dedicated support team treats your queries with the highest priority and actions the prompt response required.

SALES/DESIGNOur team provides technical expertise for any design, information or product-related query.

SERVICE CALLIn the event of non-engineered alterations or other unforeseen events that might require product maintenance, our team will reach you at the earliest to bring the system back to normal operations swiftly.

MODIFICATION CALLThere can be a need to alter or modify the Power Distribution System post installation due to changes in layout. Should you require such modifications, you can trust us to carry it out without much wastage of existing routes and with minimum operational interferences and downtime.

AFTER SALES &CLIENT SUPPORT

CLIENT SUPPORTWe realize that the application of Busbar Trunking product requires an integrated and coherent acceptance between consultant, contractor and manufacturer. That is why we have a dedicated Client Support team consisting of trained technical staff with a solid grip on product knowledge and a deep understanding of consultant and contractor requirements to formulate customized solutions focusing on the following factors:

Electrical load requirements

Nature of load

Suitability of the product

Site compatibility

Layout design

Cost factor

Flexibility

This offers our clients an integrated support system and helps them make quick and efficient decisions without having to go through several rounds of time-consuming meetings on technical and non-technical matters.

The application of Busbar Trunking product requires an integrated and coherent acceptance between consultant, contractor and manufacturer.