sales reference drawings · 2020. 2. 24. · imperial dimensions notes: 1 the duty cycle for...

8
Series 70 - Electric Actuators SALES REFERENCE DRAWINGS

Upload: others

Post on 25-Jul-2021

1 views

Category:

Documents


0 download

TRANSCRIPT

Page 1: SALES REFERENCE DRAWINGS · 2020. 2. 24. · Imperial Dimensions Notes: 1 The duty cycle for intermittent on-off operation is 25% The continuous duty actuator with Servo is rated

Seri

es

70 -

Ele

ctri

c A

ctu

ato

rs

SA

LES R

EFE

REN

CE D

RA

WIN

GS

Page 2: SALES REFERENCE DRAWINGS · 2020. 2. 24. · Imperial Dimensions Notes: 1 The duty cycle for intermittent on-off operation is 25% The continuous duty actuator with Servo is rated

Page 2

Electric Actuators

SALES REFERENCE DRAWINGS

Table of Contents

Imperial DimensionsWeatherproof NEMA Type 4, 4X & IP65

003 to 065 3S70-130/131 and S70-180/181 4

Weatherproof NEMA Type 4, 4X & IP65 / Hazardous LocationS70-708 to S70-720 5

Metric DimensionsWeatherproof NEMA Type 4, 4X & IP65

003 to 065 670-130/131 and S70-180/181 7

Page 3: SALES REFERENCE DRAWINGS · 2020. 2. 24. · Imperial Dimensions Notes: 1 The duty cycle for intermittent on-off operation is 25% The continuous duty actuator with Servo is rated

Page 3

NOTE:1) All dimensions in inches2) Handwheel Spinner is optional

øA

G C

øR

øN

PM

KF

Q

D

ALLOW 4.00 FORCOVER REMOVAL

SEENOTE 2

#10-24 x .39 DEEP4 PLACES

CONDUIT (ENTRY 2 PLACES)

3.00

3.00.78 TYP.

1.251.36

B

J

H

E0.47

ø1.97 x 2.65 DEEP

ES11A-0226

SPINNERNOTSHOWNSEE NOTE 2

DETAIL AFOR 3000 & LARGER

.6 MAX. FOR OVERRIDE ENGAGEMENT

Series 70 Electric ActuatorImperial Dimensions

Sales Reference Drawing #70-003 to 065Inquire/P.O. No.:_____________________________________

Bray Order No.: ____________________________________

Customer/Project: ___________________________________

Notes:1 The duty cycle for intermittent on-off operation is 25% The continuous duty actuator with Servo is rated for 100% modulating

operation

2 Handwheel Spinner shown in drawing is available as an option

3 Dimension (N) is also available with Double Square (Star) drive

Drawings are for reference only. Please refer to Bray ES and GA drawings on the Bray website, www.bray.com. Bray reserves the right to change product dimensions without notice.

Weatherproof NEMA Type 4, 4X & IP65 003 to 065

IMPERIAL DIMENSIONS - InchesActuator

SizeTorque(in-lbs) A B C D E F G H

NPTJ

K(UNC) x B.C.

M (UNC) x B.C. N P Q øR Weight.

lbs

S70-003S70-006

300600

7.5 5.8 3.0 5.6 1.9 1.94 .19 1/2 2.2 5/16-18 x ø2.76 — .75 .51 1.75 3.5 13

S70-008S70-012S70-020

800 1200 2000

10.1 7.8 3.7 6.6 2.4 2.69 .56 3/4 2.6 5/16-18 x ø2.76 1/2-13 x ø4.92 1.18 .87 2.22 8.0 28

S70-030S70-050S70-065

3000 5000 6500

12.1 9.5 5.5 7.2 2.9 3.19 .56 3/4 3.1 1/2-13 x ø4.92 3/4-10 x ø6.50 See Detail A 12.0 48

Page 4: SALES REFERENCE DRAWINGS · 2020. 2. 24. · Imperial Dimensions Notes: 1 The duty cycle for intermittent on-off operation is 25% The continuous duty actuator with Servo is rated

Page 4

Series 70 Electric ActuatorImperial Dimensions

Notes:1 The duty cycle for intermittent on-off operation is 25% The continuous duty actuator with Servo is rated for 100% modulating

operation

2 Dimension (N) is also available with Double Square (Star) drive

Drawings are for reference only. Please refer to Bray ES and GA drawings on the Bray website, www.bray.com. Bray reserves the right to change product dimensions without notice.

Weatherproof NEMA Type 4, 4X & IP65S70-130/131 and S70-180/181

IMPERIAL DIMENSIONS - InchesActuator

Size A B C D E F G H NPT

JK

(UNC) x B.C.M (UNC)x B.C. N P Q øR S T U Weight.

lbs S70-130/131 S70-180/181

12.1 9.5 15.3 12.5 8.1 3.5 .56 3/4 8.3 1/2-13 x ø4.921F12

3/4-10 x ø6.496F16

See Stem Bore Detail

12.0 6.1 12.7 8.0 118

STEM BORE DETAIL

P

øN

Q

H 3/4 NPTCONDUIT ENTRY

2 PLACES

#10–24 x .39 DEEP4 PLACES

ALLOW 2.5FOR COVER REMOVAL

.6 MAX.FOR OVERRIDEENGAGEMENT

D12.5

J8.3

1.3

9.5B

5.4STEM

MAXENTRY

E8.1

.78 2 PLACES

3.00M 3/4–10UNC x 1.25 DEEP

4 PLACESON ø6.496 BC

K 1/2–13UNC x .94 DEEP4 PLACES

ON ø4.921 BC

F 3.5

C15.3

U 8.0

T12.7

S6.1

ø12.1A

Rø12.0

G.56

STEM BORE DETAIL

SizeTorque (in-lbs )

Speed (sec )

N P QWt (lbs)

70-1306 13,000 110 2 51 0 63 3 05 118

70-1316 13,000 110 1 97 0 47 2 38 118

70-1806 18,000 110 2 51 0 63 3 05 118

70-1816 18,000 110 1 97 0 47 2 38 118

Sales Reference Drawing #70-130/131-180/181Inquire/P.O. No.:_____________________________________

Bray Order No.: ____________________________________

Customer/Project: ___________________________________

Page 5: SALES REFERENCE DRAWINGS · 2020. 2. 24. · Imperial Dimensions Notes: 1 The duty cycle for intermittent on-off operation is 25% The continuous duty actuator with Servo is rated

Page 5

Series 70 Electric ActuatorImperial Dimensions

IMPERIAL DIMENSIONS - InchesActuator

SizeTorque(in-lbs) A B C D E F G H J

K(UNC) x B.C.

M (UNC) x B.C. N P Q øR Weight

lbsS70-708S70-712S70-720

80012002000

12.5 8.0 3.7 7.7 2.4 2.69 .56 3/4 2.6 5/16-18 x ø2.76 F07

1/2-13 x ø4.92 F12 1.18 .87 2.01 8.0 34

Notes:

1 The duty cycle for intermittent on-off operation is 25%

2 Handwheel Spinner shown in drawing is available as an option

Drawings are for reference only. Please refer to Bray ES and GA drawings on the Bray website, www.bray.com. Bray reserves the right to change product dimensions without notice.

BALLOW 3.12

FOR COVER REMOVAL

TYP .78

J E

.6 MAX. FOR OVERRIDEENGAGEMENT

3.00 See Note 2

øRD

øA

G C

CLOSE

OPEN

øN x Q DEEP

SPINNER NOTSHOWN SEENOTE 2

F

M

P

H NPT CONDUIT ENTRY 2 PLACES

KTYP.4 PLACES

TYP.4 PLACES

Weatherproof NEMA Type 4, 4X & IP65 / Hazardous LocationS70-708 to S70-720

Sales Reference Drawing #70-708/712/720Inquire/P.O. No.:_____________________________________

Bray Order No.: ____________________________________

Customer/Project: ___________________________________

Page 6: SALES REFERENCE DRAWINGS · 2020. 2. 24. · Imperial Dimensions Notes: 1 The duty cycle for intermittent on-off operation is 25% The continuous duty actuator with Servo is rated

Page 6

NOTE:1) All dimensions in metric.2) Handwheel spinner is optional

DETAIL AFOR 338.95 Nm & LARGER

ALLOW 101.6 FORCOVER REMOVAL

SEENOTE 2

H CONDUITENTRY 2 PLCS.

M5-0.8 X 9.9 DEEP4 PLACES

B

J E

G C

øA

ø50.0 x 67.4 DEEP

D

F

P

øN Q DEEP

K TYP. 4 PL.

M TYP. 4 PL.

ES12A-0499

øR SPINNERNOTSHOWNSEE NOTE 2

34.6

15 MAX. FOROVERRIDEENGAGEMENT

Series 70 Electric ActuatorMetric Dimensions

Weatherproof NEMA Type 4, 4X & IP65 003 to 065

METRIC DIMENSIONS - MillimetersActuator

SizeTorque(Nm) øA B C D E F G H J K x B.C. M x B.C. N P Q øR Weight.

kgs

S70-003S70-006

3468

191 147 76 141 48 49.2 4.7 M20 x 1.5 55 M8 x 1.25 x ø70 — 19.0 13.0 44.5 89 6

S70-008S70-012S70-020

90 136 226

256 198 93 168 62 68.3 14.3 M25 x 1.5 66 M8 x 1.25 x ø70 M12 x 1.75 x ø125 30.0 22.0 56.3 203 13

S70-030S70-050S70-065

339 565 734

308 241 139 183 73 80.9 14.3 M25 x 1.5 78 M12 x 1.75 x ø125 M20 x 2.5 x ø165 See Detail A 305 22

Notes:1 The duty cycle for intermittent on-off operation is 25% The continuous duty actuator with Servo is rated for 100% modulating

operation

2 Handwheel Spinner shown in drawing is available as an option

3 Dimension (N) is also available with Double Square (Star) drive

Drawings are for reference only. Please refer to Bray ES and GA drawings on the Bray website, www.bray.com. Bray reserves the right to change product dimensions without notice.

Sales Reference Drawing #70-003 to 065Inquire/P.O. No.:_____________________________________

Bray Order No.: ____________________________________

Customer/Project: ___________________________________

Page 7: SALES REFERENCE DRAWINGS · 2020. 2. 24. · Imperial Dimensions Notes: 1 The duty cycle for intermittent on-off operation is 25% The continuous duty actuator with Servo is rated

Page 7

P

øN

Q

D

J

M4 PLACES

F

C

U203

GR

305

A

S155

T322

HCONDUIT ENTRY

2 PLACES

M5-0.8 x 9.9 DEEP4 PLACES

ALLOW 64FOR COVER REMOVAL

31.8

19.8 2 PLACES

E136.0 MAXSTEM ENTRY

B15 MAXFOR OVERRIDEENGAGEMENT

K4 PLACES

Series 70 Electric ActuatorMetric Dimensions

Weatherproof NEMA Type 4, 4X & IP6570-130/131 and S70-180/181

METRIC DIMENSIONS - MillimetersActuator

Size A B C D E F G H JK

(MM) x B.C.M (MM)x B.C. N P Q øR S T U Weight.

kgsS70-130/131 S70-180/181

308 241 389 316 206 89 14.3 1.5 212 12 x 125 BC x 23.9 20 x 165 BC x 31.8See

Stem Bore Detail305 155 322 203 54

STEM BORE DETAIL

SizeTorque (Nm)

Speed (sec )

N P QWt (kg)

70-1301 1,469 110 63 6 15 9 77 5 54

70-1311 1,469 110 50 0 12 0 60 6 54

70-1801 2,034 110 63 6 15 9 77 5 54

70-1811 2,034 110 50 0 12 0 60 6 54

Notes:1 The duty cycle for intermittent on-off operation is 25% The continuous duty actuator with Servo is rated for 100% modulating

operation

2 Dimension (N) is also available with Double Square (Star) drive

Drawings are for reference only. Please refer to Bray ES and GA drawings on the Bray website, www.bray.com. Bray reserves the right to change product dimensions without notice.

Sales Reference Drawing #70-130/131-180/181Inquire/P.O. No.:_____________________________________

Bray Order No.: ____________________________________

Customer/Project: ___________________________________

Page 8: SALES REFERENCE DRAWINGS · 2020. 2. 24. · Imperial Dimensions Notes: 1 The duty cycle for intermittent on-off operation is 25% The continuous duty actuator with Servo is rated

All statements, technical information, and recommendations in

this bulletin are for general use only. Consult Bray representatives

or factory for the specific requirements and material selection for

your intended application. The right to change or modify product

design or product without prior notice is reserved. Patents issued and

applied for worldwide.

Bray® is a registered trademark of

Bray International, Inc.

© 2017 Bray International, Inc. All rights reserved.

SRD_Electric Actuators_7_31_2017

Bray International, Inc.13333 Westland East Blvd.Houston, Texas 77041Tel: 281.894.5454 • bray.com