sample data sheet – oil analysis

1
Reason: Equipment ID: Phase: MR-Order No.: Report No.: SAMPLE DATA SHEET – OIL ANALYSIS. WWW.REINHAUSEN.COM THE POWER BEHIND POWER. Company: Customer No.: Address: Contact: E-mail: Phone: Fax: Equipment: Cooling Type: £ AN £ ONAN £ ONAF £ OFAF £ OFWF £ Other: Breathing: £ Free breathing £ Sealed £ Rubber bag £ N 2 -Blanket £ Other: £ Network £ Furnace £ Generator £ Wind power £ Rectifier £ Other: Transformer: OLTC: Type : Operation count: Online filtration: Yes £ No £ Equipment details: Manufacturer: Location: Substation: Serial No.: Year of constr.: Primary voltage: Max MVA Rating: Status: £ In service £ New oil £ Reclamation: . . / . . / . . . . £ Other: . . / . . / . . . . Sample: £ DGA analysis IEC 60567 / ASTM D3612 £ Moisture IEC 60814 / ASTM D1533 £ Disruptive / Breakdown voltage IEC 60156 / ASTM D877/1816 £ Dielectric dissipation factor (tan d) IEC 60247 / ASTM D924 £ Determination of elements (metal, sulphur) DIN 51399-1 £ DC resistivity IEC 60247 / ASTM D1169 £ Solids content, overall IEC 60422, Annex C £ Determination of sludge IEC 60422, Annex C £ Density 15°C ISO 12185 or 3675 / ASTM D1298 £ Visual inspection - £ Neutralization number / acidity IEC 62021 / ASTM D974 £ Interfacial tension ASTM D 971-12 £ Viscosity (40°C, 100°C) ISO 3104 / ASTM D445 £ Oxidation stability IEC 61125 / ASTM D2440 Insulating Oil Tests £ Color index ISO 2049 / ASTM D1500 £ Flash point ISO 2719 / ASTM D93 £ Pour point ISO 3016 / ASTM D97 £ PCB-content IEC 61619 / ASTM D4059 £ Corrosive sulphur (copper strip) IEC 62535 / ASTM D1275B £ Corrosive sulphur (silver strip) DIN 51353 £ DBDS content IEC 62697-1 / ASTM £ Inhibitor content IEC 60666 / ASTM D4768 £ Metal passivator IEC 60666 £ Particle count IEC 60970 / ASTM D6786 £ Furan Analysis (with calculated DP) IEC 61198 / ASTM D5837 £ Methanol, Ethanol (with calculated DP) ASTM D 7843 £ Insulation paper DP and moisture content IEC 60450 / ASTM D4243 £ Other oil quality tests: TD2952503/05 – SAMPLE DATA SHEET – 77973705 - 05/18 – ©Messko GmbH 2018 Sample ID: Sampled by: Top Oil temperature: Date sampled: . . / . . / . . . . Amount of oil in the equipment [liter]: Brand name oil: Paper type / Temp. rise: Oil type: £ Mineral oil £ Natural ester £ Synthetic ester £ Silicone £ Other: Sampling port transformer: £ Bottom £ Middle £ Top £ Conservator Sampling port LTC: £ Selector £ Diverter £ Column (A, B, C): £ Conservator Sampling container: £ Glass syringe £ Aluminium bottle £ Plastic bottle £ Other: Check tests to be performed £ Rush £ Routine £ MSense £ Event based Oil sampling: £ Transformer £ OLTC £ Container £ Bushing £ Cablebox £ Other: (for internal use only) Û see LTC Nameplate; if unknown please enter vacuum or oil switching type Û MSENSE® DGA adjustment: Serial No.: Installation Date: . . / . . / . . . . Installation Place: Displayed values during sampling: H 2 CO H 2 O Timestamp:

Upload: others

Post on 05-May-2022

8 views

Category:

Documents


0 download

TRANSCRIPT

Page 1: SAMPLE DATA SHEET – OIL ANALYSIS

Reason:

Equipment ID: Phase:

MR-Order No.:

Report No.:

SAMPLE DATA SHEET – OIL ANALYSIS.

WWW.REINHAUSEN.COM

THE POWER BEHIND POWER.

Company: Customer No.:

Address:

Contact: E-mail:

Phone: Fax:

Equipment:

Cooling Type: £ AN £ ONAN £ ONAF £ OFAF £ OFWF £ Other:

Breathing: £ Free breathing £ Sealed £ Rubber bag £ N2-Blanket £ Other:

£ Network £ Furnace £ Generator £Wind power £ Rectifier £ Other: Transformer:

OLTC: Type : Operation count: Online filtration: Yes £ No £

Equipment details: Manufacturer: Location: Substation:

Serial No.: Year of constr.: Primary voltage: Max MVA Rating:

Status: £ In service £ New oil £ Reclamation: . . / . . / . . . . £ Other: . . / . . / . . . .

Sample:

£ DGA analysis IEC 60567 / ASTM D3612

£Moisture IEC 60814 / ASTM D1533

£ Disruptive / Breakdown voltage IEC 60156 / ASTM D877/1816

£ Dielectric dissipation factor (tan d) IEC 60247 / ASTM D924

£ Determination of elements (metal, sulphur) DIN 51399-1

£ DC resistivity IEC 60247 / ASTM D1169

£ Solids content, overall IEC 60422, Annex C

£ Determination of sludge IEC 60422, Annex C

£ Density 15°C ISO 12185 or 3675 / ASTM D1298

£ Visual inspection -

£ Neutralization number / acidity IEC 62021 / ASTM D974

£ Interfacial tension ASTM D 971-12

£ Viscosity (40°C, 100°C) ISO 3104 / ASTM D445

£ Oxidation stability IEC 61125 / ASTM D2440

Insulating Oil Tests

£ Color index ISO 2049 / ASTM D1500

£ Flash point ISO 2719 / ASTM D93

£ Pour point ISO 3016 / ASTM D97

£ PCB-content IEC 61619 / ASTM D4059

£ Corrosive sulphur (copper strip) IEC 62535 / ASTM D1275B

£ Corrosive sulphur (silver strip) DIN 51353

£ DBDS content IEC 62697-1 / ASTM

£ Inhibitor content IEC 60666 / ASTM D4768

£Metal passivator IEC 60666

£ Particle count IEC 60970 / ASTM D6786

£ Furan Analysis (with calculated DP) IEC 61198 / ASTM D5837

£Methanol, Ethanol (with calculated DP) ASTM D 7843

£ Insulation paper DP and moisture content IEC 60450 / ASTM D4243

£ Other oil quality tests:

TD2952503/05 – SAMPLE DATA SHEET – 77973705 - 05/18 – ©Messko GmbH 2018

Sample ID: Sampled by: Top Oil temperature: Date sampled: . . / . . / . . . .

Amount of oil in the equipment [liter]: Brand name oil: Paper type / Temp. rise:

Oil type: £Mineral oil £ Natural ester £ Synthetic ester £ Silicone £ Other:

Sampling port transformer: £ Bottom £Middle £ Top £ Conservator

Sampling port LTC: £ Selector £ Diverter £ Column (A, B, C): £ Conservator

Sampling container: £ Glass syringe £ Aluminium bottle £ Plastic bottle £ Other:

Check tests to be performed

£ Rush £ Routine £MSense £ Event based

Oil sampling: £ Transformer £ OLTC £ Container £ Bushing £ Cablebox £ Other:

(for internal use only)

Û

see LTC Nameplate; if unknown please enter vacuum or oil switching type

Û

MSENSE® DGA adjustment:

Serial No.: Installation Date: . . / . . / . . . . Installation Place:

Displayed values during sampling: H2 CO H2O Timestamp: