16
SAMSON LIQUID RING VACUUM PUMPS KE-SERIES Range: 33 mbar, absolute to 3.5 bar, gauge Capacity: From 150 m 3 /h to 320 m 3 /h OFFSHORE FISH FOOD TRUCKS PROCESS DATASHEET KE-SERIES DOC1013

Upload: others

Post on 24-Jan-2021

10 views

Category:

Documents


0 download

TRANSCRIPT

  • SAMSON LIQUID RING VACUUM PUMPS KE-SERIES

    Range: 33 mbar, absolute to 3.5 bar, gauge

    Capacity: From 150 m3/h to 320 m3/h

    OFFSHORE FISHFOODTRUCKS PROCESS

    DATASHEET KE-SERIES

    DOC1013

  • KE SERIES

    Index Page

    About SAMSON PUMPS................................................................................................................... 4

    Materials........................................................................................................................................... 5

    Technical data................................................................................................................................... 6

    Dimensions....................................................................................................................................... 7

    KE180 vacuum performance ........................................................................................................... 8

    KE180 pressure performance .......................................................................................................... 9

    KE225 vacuum performance............................................................................................................ 10

    KE225 pressure performance .......................................................................................................... 11

    KE200 pressure performance (Vacuum performance only)................................................................ 12

    KE300 vacuum performance (Vacuum performance only)................................................................. 13

    Accessories..................................................................................................................................... 14

    How to order KE.............................................................................................................................. 15

    SAMSON LIQUID RING VACUUM PUMPS

  • ABOUT SAMSON PUMPS

    SAMSON PUMPS was established in 1938 by the local blacksmith in a small town near Viborg, Denmark. It all started with a production of machinery and tools for local farmers.

    Now with more than 40 years of experience in liquid ring vacuum pumps and vacuum technology SAMSON PUMPS has a large number of equipment installed in industries worldwide. SAMSON vacuum pumps are well known for its strength, reliablity and low maintenance costs.

    Quality

    All SAMSON vacuum pumps are tested before shipment from the factory.

    Delivery

    SAMSON PUMPS has a large amount of standard pumps on stock and we are known for our short lead time.

    Service

    SAMSON PUMPS has service facilities and all repaired pumps are tested to fulfill the original specifications.

    Main markets

    • Fish Industry

    • Offshore

    • Waste handling

    • Food industry

    • Truck building industry

    SAMSON LIQUID RING VACUUM PUMPS

    4

    KE SERIES

  • KE SERIES

    MATERIALS

    Position / Components Material KE180 KE200 KE225 KE300

    1: Pump housing Cast iron EN-GJL-250; EN 1561 • • • •

    2: Branch pipes * Cast iron EN-GJL-250; EN1561 • • • •3: Shell Cast iron EN-GJL-250; En 1561 • • • •

    4: Rotor Cast iron EN-GJS-400-15; EN 1561 — • — •

    Stainless steel EN 1.4404 • — • —

    5: Rotor shaft Stainless steel EN 1.4418 • • • •

    6: Flow plates Cast iron EN-GJL-250; EN 1561 • • • •

    Stainless steel AISI 316 • • • •

    7: Mechanical shaft seal Stainless steel/NBR EN 1.4301/NBR • • • •

    8: O-rings Nitrile NBR • • • •

    Ethylene Proylene Diene Monomer EPDM • • • •

    VITON FKM • • • •

    9: Gaskets Paper gasket Oil resistant • • • •

    Available = • Not available = — * = Build-in

    SAMSON LIQUID RING VACUUM PUMPS

    5

    Doc.1622051_2

    11 2

    34

    5

    66

    7

    7

    99

    8

    8

  • SAMSON LIQUID RING VACUUM PUMPS

    6

    TECHNICAL DATA

    KE180 KE200 KE225 KE300

    Weight Ex. branch pipes [kg] — — — —

    Incl. branch pipes * [kg] 79 82,5 85 89,5Sound pressure [db(A)] 70 70 70 70

    Pressure test [bar, gauge] 5 5 5 5

    Rotation speed range [rpm] 1.200 - 1.800

    Temperature Gas temp, max [°C] 120 120 120 120

    ATEX, Gas temp, max [°C] — — — —

    Service liquid temp, max [°C] 90 90 90 90

    ATEX, service liquid temp, max [°C] — — — —

    Bearing type Ball bearing, DE • • • •

    Ball bearing, NDE • • • •

    Roller bearing, spheric, DE — — — —

    Roller bearing, spheric, NDE — — — —

    Pump colour RAL code RAL 5021 • • • •

    Connection, water supply Nipple hose 1/2”/Ø16 • • • •

    Approvals ATEX certified Ex II2 G c T4 (zone 1) — — — —

    Available = • Not available = — * = Build-in

    KE SERIES

  • DIMENSIONS [mm]

    Pump type A B C D E F H HB K KB L M N P

    KE180 505 329 269 142 60 Ø30/k6 160 320 251 200 Ø125 Ø18 1/2” / Ø16 Ø40

    KE200 505 329 269 142 60 Ø30/k6 160 320 251 200 Ø125 Ø18 1/2” / Ø16 Ø40

    KE225 550 374 314 142 60 Ø30/k6 160 320 251 200 Ø125 Ø18 1/2” / Ø16 Ø40

    KE300 550 374 314 142 60 Ø30/k6 160 320 251 200 Ø125 Ø18 1/2” / Ø16 Ø40

    KE SERIES

    SAMSON LIQUID RING VACUUM PUMPS

    7

    S

    H

    HB

    KB

    K

    A

    B

    C D

    E

    P

    F

    M

    L

    N(Water supply)

    Outlet (cw rotation)Inlet (ccw rotation)

    Inlet (cw rotation)Outlet (ccw rotation)

    Doc.1622051_3

  • SAMSON LIQUID RING VACUUM PUMPS

    8

    KE180 VACUUM PERFORMANCE - DRY AIR KE180 POWER CONSUMPTION - VACUUM

    Air temperature 20°CSealing water temperature 15°CPerformance based on dry air at 1013 mbar absoluteTolerance +/- 10%

    CORRECTION FACTOR BASED ONSEALING LIQUID TEMPERATURE

    Qt = Q15 * KPump performance at temperature of sealing liquid higher than 15°C

    1750 RPM

    1450 RPM

    1200 RPM

    800

    Q15 m/h

    300

    0

    200 400 600 mbar absolute

    3

    250

    200

    150

    100

    501200 RPM

    1450 RPM

    1750 RPM

    800

    0

    200 400 600

    10

    kW

    8

    2

    4

    6

    mbar absolute

    0,2

    10

    0,4

    0,6

    0,8

    1,0

    0

    K1

    100 1000

    15oC

    20oC

    30oC

    40oC

    50oC Cavitation

    limits

    mbar abs

    KE180 - Vacuum performance

    VACUUM OPERATION:

    Performance and power consumption are based on a constant service liquid pressure at +/- 0.2 bar gauge. Deviations will affect the performance and power consumption.Using a liquid seperator from Samson Pumps the amount of water will be regulated automatically depending on the operating pressure. At the same time the water will be reused and will reduce the costs of operation.If operating without liquid seperator, the pump must be supplied with 0.2 m3/h as a minimum in considerations to lubrication and cooling of the mechanical shaft seals.

  • SAMSON LIQUID RING VACUUM PUMPS

    9

    KE180 Pressure performance

    KE180 Power consumption (pressure)

    Air termperature 20°C, Sealing water temperature 15°CTolerance ± 10%

    1750 RPM

    1450 RPM

    Q m/h

    0

    bar gauge

    3

    0

    50

    0,5 1,0 1,5

    100

    150

    200

    250

    1750 RPM

    1450 RPM

    KW

    0bar gauge0

    5

    0,5 1,0 1,5

    10

    15

    KE180 - Pressure performance

    PRESSURE OPERATION:

    Performance and power consumption are based on a constant service liquid flow at 1.5 m3/h. Deviations will affect the performance and power consumption.Using a liquid seperator from Samson Pumps the amount of water will be regulated automatically depending on the operating pressure. At the same time the water will be re-used and will reduce the costs of operation.If operating without liquid seperator the pump must be supplied with 0.2 m3/h as a minimum in considerations to lubrication and cooling of the mechanical shaft seals.

  • SAMSON LIQUID RING VACUUM PUMPS

    10

    KE225 VACUUM PERFORMANCE - DRY AIR

    0,2

    10

    0,4

    0,6

    0,8

    1,0

    0

    K1

    100 1000

    15oC

    20oC

    30oC

    40oC

    50oC Cavitation

    limits

    KE225 POWER CONSUMPTION - VACUUM

    Air temperature 20°CSealing water temperature 15°CPerformance based on dry air at 1013 mbar absoluteTolerance +/- 10%

    CORRECTION FACTOR BASED ONSEALING LIQUID TEMPERATURE

    Qt = Q15 * KPump performance at temperature of sealing liquid higher than 15°C

    1750 RPM

    1450 RPM

    1200 RPM

    800

    Q15 m/h

    300

    0

    200 400 600 mbar absolute

    3

    250

    200

    150

    100

    50

    1200 RPM

    1450 RPM

    1750 RPM

    800

    0

    200 400 600

    10

    kW

    8

    2

    4

    6

    mbar absolute

    mbar abs

    KE225 - Vacuum performance

    VACUUM OPERATION:

    Performance and power consumption are based on a constant service liquid pressure at +/- 0.2 bar gauge. Deviations will affect the performance and power consumption.Using a liquid seperator from Samson Pumps the amount of water will be regulated automatically depending on the operating pressure. At the same time the water will be reused and will reduce the costs of operation.If operating without liquid seperator, the pump must be supplied with 0.2 m3/h as a minimum in considerations to lubrication and cooling of the mechanical shaft seals.

  • SAMSON LIQUID RING VACUUM PUMPS

    11

    KE225 Pressure performance

    KE225 Power consumption (pressure)

    Air termperature 20°C, Sealing water temperature 15°CTolerance ± 10%

    1750 RPM

    1450 RPM

    Q m/h

    0

    bar gauge

    3

    0

    50

    0,5 1,0 1,5

    100

    150

    200

    250

    300

    1750 RPM

    1450 RPM

    KW

    0

    bar gauge0

    5

    0,5 1,0 1,5

    10

    15

    20

    PRESSURE OPERATION:

    Performance and power consumption are based on a constant service liquid flow at 1.5 m3/h. Deviations will affect the performance and power consumption.Using a liquid seperator from Samson Pumps the amount of water will be regulated automatically depending on the operating pressure. At the same time the water will be re-used and will reduce the costs of operation.If operating without liquid seperator the pump must be supplied with 0.2 m3/h as a minimum in considerations to lubrication and cooling of the mechanical shaft seals.

    KE225 - Pressure performance

  • SAMSON LIQUID RING VACUUM PUMPS

    12

    KE200 VACUUM PERFORMANCE - DRY AIR

    KE200 POWER CONSUMPTION - VACUUM CORRECTION FACTOR BASED ONSEALING LIQUID TEMPERATURE

    Air temperature 20°CSealing water temperature 15°CPerformance based on dry air at 1013 mbar absoluteTolerance +/- 10%

    Qt = Q15 * KPump performance at temperature of sealing liquid higher than 15°C

    60

    Q15 m/h

    300

    0

    30 40 50

    3

    250

    200

    150

    100

    50

    1750 RPM

    1450 RPM

    1200 RPM

    800200 400 600 mbar absolute8070 100

    1200 RPM

    1450 RPM

    1750 RPM

    800

    0

    200 400 600

    10

    kW

    8

    2

    4

    6

    mbar absolute

    0,2

    10

    0,4

    0,6

    0,8

    1,0

    0

    K1

    100 1000

    15oC

    20oC

    30oC

    40oC

    50oC Cavitation

    limits

    mbar abs

    KE200 - Vacuum performance

    VACUUM OPERATION:

    Performance and power consumption are based on a constant service liquid pressure at +/- 0.2 bar gauge. Deviations will affect the performance and power consumption.Using a liquid seperator from Samson Pumps the amount of water will be regulated automatically depending on the operating pressure. At the same time the water will be reused and will reduce the costs of operation.If operating without liquid seperator, the pump must be supplied with 0.2 m3/h as a minimum in considerations to lubrication and cooling of the mechanical shaft seals.

  • SAMSON LIQUID RING VACUUM PUMPS

    13

    KE300 VACUUM PERFORMANCE - DRY AIR

    KE300 POWER CONSUMPTION - VACUUM CORRECTION FACTOR BASED ONSEALING LIQUID TEMPERATURE

    Air temperature 20°CSealing water temperature 15°CPerformance based on dry air at 1013 mbar absoluteTolerance +/- 10%

    Qt = Q15 * KPump performance at temperature of sealing liquid higher than 15°C

    60

    Q15 m/h

    300

    0

    30 40 50

    3

    250

    200

    150

    100

    50

    1750 RPM

    1450 RPM

    1200 RPM

    800200 400 600 mbar absolute8070 100

    350

    1200 RPM

    1450 RPM

    1750 RPM

    800

    0

    200 400 600

    10

    kW

    8

    2

    4

    6

    mbar absolute

    mbar abs

    0,2

    10

    0,4

    0,6

    0,8

    1,0

    0

    K1

    100 1000

    15oC

    20oC

    30oC

    40oC

    50oC Cavitation

    limits

    KE300 - Vacuum performance

    VACUUM OPERATION:

    Performance and power consumption are based on a constant service liquid pressure at +/- 0.2 bar gauge. Deviations will affect the performance and power consumption.Using a liquid seperator from Samson Pumps the amount of water will be regulated automatically depending on the operating pressure. At the same time the water will be reused and will reduce the costs of operation.If operating without liquid seperator, the pump must be supplied with 0.2 m3/h as a minimum in considerations to lubrication and cooling of the mechanical shaft seals.

  • SAMSON LIQUID RING VACUUM PUMPS

    14

    KE SERIES

    ACCESSORIES

    KE180 KE200 KE225 KE300

    Non return valve — — — —

    Vacuum limiter • • • •

    Service liquid valve • • • •

    4-way valve • • • •

    4-way valve with pneumatic actuator • • • •

    Intermediate pipe for 4-way valve • • • •

    Adaptor for hydraulic motor ISO — — — —

    Adaptor for hydraulic motor SAE — — — —

    Liquid seperator • • • •

    Temperature control, partiel recovery • • • •

    Temperatur control, full recovery • • • •

    Available = • Not available = —

  • KE SERIES

    Exsample: KE 200 R 0 S S S 0 0 A SD

    Model:

    KE 180

    KE 200

    KE 225

    KE 300

    Rotation:

    Clockwise R

    Counter clockwise L

    Rotor type:

    Welded AISI 316 0

    Cast iron EN-GJS-400-15; EN1561 1

    Pump housing:

    Cast iron EN-GJL-250; EN1561 S

    Shell:

    Cast iron EN-GJL-250; EN1561 S

    Flow plates:

    Cast iron EN-GJL-250; EN1561 S

    Stainless steel AISI 316 E

    Mechanical shaft seals:

    NBR / AISI 316 0

    EPDM / AISI 316 1

    Teflon / AISI 316 2

    Gaskets:

    Oakenstrong 0

    Colour:

    Samson standard A

    Without paint 0

    On request X

    Documentation:

    Samson standard SD

    HOW TO ORDER KE

    SAMSON LIQUID RING VACUUM PUMPS

    15

  • Samson Pumps A/SPetersmindevej 21 DK-8800 Viborg