Contents

• Introduction to Access Control and User Credentials• Standalone Controllers• Control Panels• Readers• Accessories• Part Codes• System Configurations• Appendix – Technical Data

Page 3: Samsung Techwin Access Control Sales Presentation 2010

Introduction

• Access control is a system which enables an authority to control access to areas and resources in a given physical facility.

• Conditions of granted accessWHOM

WHEREHOW

WHEN

Controlled Access Points

Authorized IndividualsSpecific Time Parameters

User Credentials

Page 4: Samsung Techwin Access Control Sales Presentation 2010

Introduction to Access Control

Lock and Key• Can secure a door.• Key will always open lock,

regardless of time.• Lost key requires lock

replacement.• No audit of granted access.• Bunches of keys are heavy to

carry.• Losing a bunch of keys

requires many expensive lock changes

Electronic Access Control• Can secure a door.• Time profiles can be added to access

levels.• Lost card key can be deactivated.• Any card can open one or all doors.• Full audit trail of successful and

denied access.• No need to replace working locks.• Door monitoring to signal ‘Door Held’

or ‘Forced’ open.• Credentials can be combined for

higher levels of security, card key, PIN number, biometric.

Page 5: Samsung Techwin Access Control Sales Presentation 2010

Samsung Techwin Access Control - Credentials

Low •Physical / Tangible Object.•Example – a card key.

Med •Something you know.•Example - a PIN .

High •Something you have.•Example – a fingerprint.

Page 6: Samsung Techwin Access Control Sales Presentation 2010

Samsung Techwin Access Control – Solutions Range

STANDALONE RANGE Entry Level, single credential standalone. Medium Secure, duel credential standalone. High Security, triple credential standalone. PC Connection possible for Time &Attendance readers. SOFTWARE, INTELLEGENT CONTROLLERS AND READERS Scalable software built on SQL Server 2005. Distributed processing. 1,2,3 and 4 door intelligent control. Proximity / Smart Card, PIN and Biometric Readers. TCP/IP Networked. Video Integration. Command and Control.

Page 7: Samsung Techwin Access Control Sales Presentation 2010

Samsung Techwin Access Control• The Samsung Access Control Range offers aesthetically designed

products built to increasing design specifications to provide a cost effective security solution tailored to an individuals need and budget.

• The standalone range offers the most cost effective small system solution and has high security options , utilising fingerprint recognition in conjunction with PIN and proximity for the most secure environments.

• Beyond the standalone range is the Samsung Access Management System – SAMS – which is built on a SQL Server database structure and includes multiple communication protocols, video integration, command and control, reporting and language options for medium to large businesses.

Page 8: Samsung Techwin Access Control Sales Presentation 2010

What are Standalone Controllers?Standalone controllers:

• do not require a connection to a computer .

• can be programmed locally once the unit is installed and has power connected.

• card key administration can be performed locally at the device

Page 9: Samsung Techwin Access Control Sales Presentation 2010

Properties of Standalone Controllers

• Cost effective complete door control.

• Proximity / Smart Card, PIN, Password and Fingerprint options.

• Direct control of door lock.– Power Fail Safe / Power Fail Secure.

• Products to satisfy increased security needs with multiple user credential and vandal resistant options.

Page 10: Samsung Techwin Access Control Sales Presentation 2010

Standalone Controller Range

SSA-S1000

SSA-S1000V

SSA-S2000

SSA-S2000V

SSA-S3010/3020/

3040

SSA-S3011/3021/

3041

SSA-S2100

SSA-S2101

Page 11: Samsung Techwin Access Control Sales Presentation 2010

Standalone Controller – SSA-S1000 / S1000VProximity Access Controller

• Cost Effective Single Door Control• Slim Aesthetic Design• Ideal Small Business Application• Vandal Resistant Option

• Features– Entry Level Access Control– Standalone (no application software required)– Up to 512 users– Power Fail Safe or Fail Secure lock type– Shadow Cards

• Vandal Resistant (V) Model– Weatherproof and Dustproof (IP68)

Technical Data Link Connection Diagram Link Setup Data Link

Page 12: Samsung Techwin Access Control Sales Presentation 2010

Standalone Controller – SSA-S2000 / S2000VProximity and PIN Access Controller

• Cost Effective Duel Technology Single Door Control• Ideal Small Business Application• Vandal Resistant Option• Second (Exit) Reader Option

• Features– Proximity + PIN (options; prox only / PIN only)– Standalone (no application software required)– Up to 512 users– 5 x Inputs, 4 x Output - programmable– Duress Function– Power Fail Safe or Fail Secure lock type

• Vandal Resistant (V) Model– Weatherproof and Dustproof (IP66)

Technical Data Link Connection Diagram Link Setup Data Link

Page 13: Samsung Techwin Access Control Sales Presentation 2010

Standalone Controller – SSA-S2100 / S2101Proximity / Smart Card & PIN, Time and Attendance Access Controller

• High Security Applications• Time and Attendance Management• Standalone + Networked Windows Reporting Application / Admin• Second Reader Connection

• Features– Up to 20,000 Users and 20,000 Event Buffer– All combinations of Proximity Card, PIN and Password– 4 x Inputs, 4 x Output – programmable + time schedule– Arm / Disarm function and interface with Intruder Alarm– Time Schedules– Two Man Operation Mode– Duress Function– Power Fail Safe or Fail Secure lock type– Controller or Networked Software Administration

Technical Data Link Connection Diagram Link

Page 14: Samsung Techwin Access Control Sales Presentation 2010

Standalone Controller – SSA-S3010 / S3011 SeriesFinger Print Recognition, Proximity / Smart Card & PIN, Time and Attendance Access Controller

• Triple User Credential, including Biometric.• High Security Applications• Time and Attendance Management• Standalone + Networked Windows Reporting Application / Admin• Second Reader Connection

• Features– Up to 4000 Finger Print Users– All combinations of Finger Print Proximity Card, PIN and Password– 4 x Inputs, 4 x Output – programmable + time schedule– Arm / Disarm function and interface with Intruder Alarm– Time Schedules– Two Man Operation Mode– Duress Function– Power Fail Safe or Fail Secure lock type– Controller or Networked Software Administration

Technical Data Link Connection Diagram Link

Page 15: Samsung Techwin Access Control Sales Presentation 2010

Standalone Part Codes

AccessControl

S S A - S □ □ □ □

Samsung

Category

S: Standalone

Type

1 : Card Only

2 : Card & PIN / Card & Finger Print

3: Card, PIN and Fingerprint

System

Format

0 : Samsung 125KHz

1 : Mifare 13.56MHz

3 : EM 125KHz

Fingerprint Users

0 : No Fingerprint

1 : 1,000 Fingerprints

2 : 2,000 Fingerprints

4 : 4,000 Fingerprints

Security Level

1: Special

Page 16: Samsung Techwin Access Control Sales Presentation 2010

Standalone SummaryModel Key Feature Application

SSA-S1000 Samsung 125KHz Proximity / 512 Users. Cost effective, entry level Access Controller.

SSA-S1000V Samsung 125KHz Proximity / 512 Users. Vandal resistant.

Cost effective, entry level Access Controller for higher physical risk areas.

SSA-S2000 Duel credential proximity and PIN / 512 users.

Higher security areas requiring duel authentication.

SSA-S2000V Duel credential proximity and PIN / 512 users. Vandal resistant.

Higher security areas requiring duel authentication with high physical risk to the controller.

SSA-S2100 Series Proximity / Smart Card + PIN, Time and Attendance. 20,000 users. Optional networked administration software.

High level security applications requiring Time and Attendance, Anti Pass Back and Arm / Disarm functions.

SSA-S3010 Series Finger Print Recognition + Proximity / Smart Card + PIN, Time and Attendance. 20,000 users. Optional networked administration software.

Top level security applications requiring Biometric recognition, Time and Attendance, Anti Pass Back and Arm / Disarm functions.

All models Controlled Access Lock Control No software necessary

Standalone controlled door access with lock control.

Page 17: Samsung Techwin Access Control Sales Presentation 2010

Standalone Controller – Questions?

Page 18: Samsung Techwin Access Control Sales Presentation 2010

Access Control Intelligent Controllers

• Intelligent door controllers provide distributed processing for the interface of access control readers, keypads, inputs and outputs back to a Host Computer.

Page 19: Samsung Techwin Access Control Sales Presentation 2010

Intelligent Controllers - Distributed Processing

• Distributed processing allows each intelligent controller to operate independent of the host computer with most of the decisions made at the controller.

• This provides instant response for door control and alarm sensing while leaving the host computer with more processing power for actions like alarm response and database updates.

Page 20: Samsung Techwin Access Control Sales Presentation 2010

Intelligent ControllersState-of-the-art Controllers at affordable prices

• Intelligent control of 1,2,3 or 4 Doors

• Communication: TCP/IP, RS232, RS485 / RS422

• Data Continuity after power failure

• Programmable Inputs / Outputs• Up to 50,000 users• Up to 50,000 event buffer• Wiegand compatible readers

Page 21: Samsung Techwin Access Control Sales Presentation 2010

Intelligent ControllersState-of-the-art Controllers at affordable prices

Single Door Controller• Small to Medium Business• Safe non-volatile Flash Data

Memory - for business continuity• Duress Mode Function• Site Arm / Disarm Function• Single door controller• Up to 50,000 users / 50,000

event buffer• Versatile 5 input / 4 output• Select TCP/IP, RS232, RS285 or

RS422 communication

Four Door Controller• Medium to Large Business• Safe non-volatile Flash Data

Memory - for business continuity• Duress Mode Function• Site Arm / Disarm Function• Up to four doors controlled• Up to 50,000 users / 29,500

event buffer• Versatile 15 input / 15 output• Select TCP/IP, RS232, RS285 or

RS422 communicationLink to: Installation Network Configuration Serial Communication

Four Door: Reader Connection Lock Connection Single Door: Reader Connection Input Connection Lock Connection

Page 22: Samsung Techwin Access Control Sales Presentation 2010

Intelligent Controller – Questions?

Link to: Installation Network Configuration Serial Communication Four Door: Reader Connection Lock Connection

Single Door: Reader Connection Input Connection Lock Connection

Page 23: Samsung Techwin Access Control Sales Presentation 2010

ReadersComprehensive range of readers to satisfy challenging security environments

Page 24: Samsung Techwin Access Control Sales Presentation 2010

ReadersComprehensive range of readers to satisfy challenging security environments

• Samsung have developed a range of highly aesthetic readers, which transmit user credentials to the Intelligent Controllers.

• Reader variations include Slim Line, Vandal Resistant, PIN Number and Biometric Fingerprint with a range of card technologies.

Page 25: Samsung Techwin Access Control Sales Presentation 2010

Readers – R1000 / R1100Comprehensive range of readers to satisfy challenging security environments

• Elegant looking proximity / smart card / EM reader

• Read Range of 10cm• Both units use the same weatherproof

(IP66)epoxy moulding, so are interchangeable depending on the wall condition or aesthetic preference

• Can be installed on metal door frame or on a wall

• Wiegand output

Link to Technical Specification Link to Wiring Diagram

Page 26: Samsung Techwin Access Control Sales Presentation 2010

Readers – R1000V / R1100VComprehensive range of readers to satisfy challenging security environments

• Elegant looking proximity / smart card / EM reader which can be mounted on a metal door frame or on a wall.

• Vandal resistant with a high level of weatherproofing (IP68) for challenging environmental conditions

• Wiegand output

Link to Technical Specification Link to Wiring Diagram

Page 27: Samsung Techwin Access Control Sales Presentation 2010

Readers – R2000 / R2000VComprehensive range of readers to satisfy challenging security environments

• Elegant looking proximity / smart card / EM reader with back-lit keypad for PIN entry in dark conditions.

• Can be mounted on metal door frame or wall.

• Vandal option is IP68 and features the capacitive touch sensitive keypad

Link to Technical Specification 2000 Link to Wiring Diagram 2000Link to Technical Specification 2000V Link to Wiring Diagram 2000V

Page 28: Samsung Techwin Access Control Sales Presentation 2010

Readers – R2010 / R2011Comprehensive range of readers to satisfy challenging security environments

• Fingerprint recognition and proximity / smart card reader for high security applications

• Auto touch sensor for fingerprint only recognition.

• Operating mode selectable by individual ID (RF Only, fingerprint only, RF + fingerprint)

Link to Technical Specification Link to Wiring Diagram

Page 29: Samsung Techwin Access Control Sales Presentation 2010

AccessCon-trol

S S A - R □ □ □ □

Sam-sung

Category

R: Reader

Type

1 : Card Only

2 : Card & PIN / Card & Finger Print

Sys-tem

Format

0 : Samsung 125KHz

1 : Mifare 13.56MHz

3 : EM 125KHz

Fingerprint Users

0 : No Fingerprint

1 : 1,000 Fingerprints

2 : 2,000 Fingerprints

4 : 4,000 Fingerprints

Version

0 ~ 9

Reader Product Codes

Page 30: Samsung Techwin Access Control Sales Presentation 2010

Reader – Questions?Comprehensive range of readers to satisfy challenging security environments

Page 31: Samsung Techwin Access Control Sales Presentation 2010

SoftwareSamsung Access Management Software

SAMS Basic and SAMS Pro (Video Integration) have a free licence which has full functionality and includes the database engine (SQL Server 2005 Express)

up to the level of 20 doors OR 100 users.

Page 32: Samsung Techwin Access Control Sales Presentation 2010

SoftwareSamsung Access Management Software

• SAMS is a programmable, integrated, computer based security system software package that provides access control, alarm point monitoring, access control administration and monitoring to the rest of the hardware system.

• Windows based Server and Client, SAMS is menu driven and easy to use.

Page 33: Samsung Techwin Access Control Sales Presentation 2010

Software – SAMS Basic and Basic LiteSamsung Access Management Software

• Scalable access management software built on an SQL Server 2005.

• Dual Monitor support• Integrated Monitoring with site map• Easy In/Output control and

monitoring with Door, Sensor, Alarm Icon on the site map

• Server (SAMS Basic)/ Client (Basic Lite) network configuration

Software Architecture

System Configuration 1

System Configuration 2

Page 34: Samsung Techwin Access Control Sales Presentation 2010

Software – SAMS Pro and Pro LiteSamsung Access Management Software

• Video Integration, Command and Control maps.

• Scalable access management software built on an SQL Server 2005.

• Dual Monitor support• Integrated Monitoring with site map• Easy In/Output control and

monitoring with Door, Sensor, Alarm Icon on the site map

• Server (SAMS Pro)/ Client (Pro Lite) network configuration

Software Architecture

System Configuration 1

System Configuration 2

Page 35: Samsung Techwin Access Control Sales Presentation 2010

Software – Questions?Samsung Access Management Software

Basic / Basic Lite Pro / Pro Lite

Software Architecture

System Configuration 1

System Configuration 2

Software Architecture

System Configuration 1

System Configuration 2

Page 36: Samsung Techwin Access Control Sales Presentation 2010

Appendix / Technical Data• SSA-S1000(V) - Connection Data / Setup

Data / Technical Data• SSA-S2000(V) – Connection Data / Panel

Description / Card Registration / Setup / Technical Data

• SSA-S21XX / S30XX – Panel Description / Basic Installation / Network Diagram / Connection Data / Technical Data

• SSA-P4XX / P1XX – Intelligent Controller / Installation / Network Configuration / Serial Communications / SSA-P4XX Reader + RTE Connection / SSA-P4XX Lock Connection / SSA-P1XX Reader Connection / SSA-P1XX Input Connection / SSA-P1XX Lock Connection 1 Door

• Reader SSA-R1000 + R1100 / Connection Data / Technical Data

• Reader SSA-R1000V + R1100V / Connection Data / Technical Data

• Reader SSA-R2000 / Connection Data / Technical Data

• Reader SSA-R2000V / Connection Data / Technical Data

• Reader SSA-R2010 / 3010 Series / Connection Data / Technical Data

• Software – Basic / Architecture / System Configuration

• Software – Pro / Architecture / System Configuration

Page 37: Samsung Techwin Access Control Sales Presentation 2010

Exit Button

DC 12V(+) Power

Door Contact

Device Wiring

PowerConnect +12V of power supply to Red wire.

Connect GND of power supply to Black wire.

Door Sensor

Connect COM terminal of door sensor to Blue wire of door sensor input.

Connect NO terminal of door sensor to GND of power supply.

Exit But-ton

Connect Green wire of exit button input to one wire between wires of exit button.

Connect GND wire of power supply to the other wire.

Standalone Controller – SSA-S1000 / S1000V – Connection Data

Proximity Access Controller

BACK

Page 38: Samsung Techwin Access Control Sales Presentation 2010

Standalone Controller – SSA-S1000 / S1000V – Connection Data

Proximity Access Controller

• Door Lock

• Alarm Device

• DC 12V(+) Power

Device Wiring

PowerConnect +12V of power supply to Red wire.

Connect GND of power supply to Black wire.

Door LockConnect (+) wire of door lock to +12V wire of power supply.

Connect (-) wire of door lock to white wire of reader module.

AlarmConnect (+) wire of Alarm to +12V wire of power supply.

Connect (-) wire of Alarm to purple wire of reader module.

Lock Type Select

In a power fail safe, connect GND wire of power supply to Yel-low wire of door lock type input.

In a power fail secure, put a floating state on Yellow wire of door lock type input.

BACK

Page 39: Samsung Techwin Access Control Sales Presentation 2010

Step 1

1) Turn the power off2) Short White & Green & Yellow wire

Step 2

1) Turn the power on2) All red led will be turned on and off twice with buzzer3) Turn the power off

Step 3

1) Disconnect White & Green & Yellow wire2) Turn power ON3) Present the card that you wish to use as master card4) Master card has been registered

SSA-S1000 / S1000V Standalone ControllerStandalone Controller – SSA-S1000 / S1000V – Setup Data

Proximity Access Controller

BACK

Page 40: Samsung Techwin Access Control Sales Presentation 2010

Standalone Controller – SSA-S1000 / S1000V – Technical DataProximity Access Controller

BACK

Page 41: Samsung Techwin Access Control Sales Presentation 2010

DC +12V(Red)

GND (Black )

• Power

• Exit Button

Yellow with Red stripe

Door Contact Connection

Green

COM NC NO

COM

NO

GND (Black )

PIR Sensor

IN#1(Orange)

IN#2(Green with White stripe)

IN#3(Brown)

GND(Black )

• PIR Sensor

Auxiliary Input #1~#3

SSA-S2000 / S2000V Standalone ControllerStandalone Controller – SSA-S2000 / S2000V – Connection Data

Proximity and PIN Access Controller

BACK

Page 42: Samsung Techwin Access Control Sales Presentation 2010

NO(Blue with White stripe)

NC(White with Red stripe)

NO (Purple)

NC(Purple with White stripe)COM (White)

X

Alarm-

+

Alarm Connection

• Door Lock

GND (Black )

DC+12V(Red ) DC+12V Power

-

+POWER FAIL SAFE

POWER FAIL SECURE

DC+12V(Red )

GND (Black )

• Exit Reader

GND (Black )

DC+12V(Red )

DATA0(Pink )

DATA1(Cyan )

DATA0(Pink )

* Connection of POWER FAIL SAFE: Door Lock

* Connection of POWER FAIL SECURE: Door Lock

COM(Gray with Red stripe)

DATA1(Cyan )

SSA-S2000 / S2000V Standalone ControllerStandalone Controller – SSA-S2000 / S2000V – Connection Data

Proximity and PIN Access Controller

BACK

Page 43: Samsung Techwin Access Control Sales Presentation 2010

• When the Main Unit operates in Selection Mode, LED is flashing.

• When a registered Card (or PIN) is read or exit button is pressed, LED will be on for 3 seconds along with the "do-mi-sol-do" melody, and Lock will be opened.• When an unregistered Card (or PIN) is read, LED will be on for 2 seconds along with the "sol-do-sol-do" melody.

•When the Main Unit operates in normal mode LED is flashing every second.

Keypad

LED Indicator

SSA-S2000 / S2000V Standalone ControllerStandalone Controller – SSA-S2000 / S2000V – Front Panel DescriptionProximity and PIN Access Controller

BACK

Page 44: Samsung Techwin Access Control Sales Presentation 2010

Step 1

1) Turn the power off2) Short Green & Orange with white stripe wires3) Turn the power on4) 3 color LED blinking with beep sound indicates the success of initial-

ization.

Step 2

1) Disconnect Orange & Orange with white stripe wires2) 3 color LED keep blinking (Initial Mode)

Step 3

1) Select the Operation Mode - Card Only (0,1,ENT) - Card + PIN (0,2,ENT) - PIN Only (0,3,ENT) - Card / PIN Combination (0,5,ENT)2) Present the card that you wish to use as master card3) Register Users or Present Master card again to exit registration ModeMaster Card Master CardUser Access Cards or PINs

SSA-S2000 / S2000V Standalone ControllerStandalone Controller – SSA-S2000 / S2000V – Master Card Registration

Proximity and PIN Access Controller

BACK

Page 45: Samsung Techwin Access Control Sales Presentation 2010

Initial Setup is required upon the first time the unit is powered-up in order to operate the unit properly.1) Registration of RF Cards for RF CARD ONLY MODE2) Registration of RF Cards with PINs for RF CARD + PIN MODE3) Registration of PIN ONLY MODE4) Registration of RF/PIN Combination MODE

1) Registration of RF Cards for RF CARD ONLY MODE 2) Registration of RF Cards with PINs for RF CARD + PIN MODE(1) Apply 12VDC to the unit.All 3 LEDs will be flashing along with a powered-up melody (do mi sol me do..do mi sol do~).(2) Press ‘0’,’1’,’ENT’ from the keypad. (RF CARD ONLY MODE )(3) Present RF Cards as follow to register Master Card and User Access Cards.

(1) Apply 12VDC to the unit.All 3 LEDs will be flashing along with a powered-up melody (do mi sol me do..do mi sol do~).(2) Press ‘0’,’2’,’ENT’ from the keypad. (RF CARD + PIN MODE )(3) Present RF Cards as follow to register Master Card and User Access Cards + 4~6 digit Personal Identification Number (PIN) for each User Access Card.

(4) The first card read becomes the Master Card and the following RF Cards are registered as User Access Cards. Once all User Access Cards have been reg-istered, present the Master Card again to complete the registration. (Please keep the Master Card in a secure location for future changes.)(5) Now, the Main Unit is entered into the normal operation mode with fac-tory defaulted settings.

(4) The first card read becomes the Master Card and the following RF Cards + PINs are registered as User Access Cards with assigned PINs. Once all User Ac-cess Cards and PINs have been registered, present the Master Card again to complete the registration. (Please keep the Master Card in a secure location for future changes.)(5) Now, the Main Unit is entered into the normal operation mode with fac-tory defaulted settings.

Master Card User Access Cards Master Card again to end task Master Card User Access Cards + PINs Master Card again to end task

SSA-S2000 / S2000V Standalone ControllerStandalone Controller – SSA-S2000 / S2000V – Initial Setup

Proximity and PIN Access Controller

BACK

Page 46: Samsung Techwin Access Control Sales Presentation 2010

3) Registration of PIN ONLY MODE 4) Registration of RF/PIN Combination MODE(1) Apply 12VDC to the unit.All 3 LEDs will be flashing along with a powered-up melody (do mi sol me do..do mi sol do~).(2) Press ‘0’,’3’,’ENT’ from the keypad. (PIN ONLY MODE)(3) Enter 4~6 digit PIN+’ENT’ to register Configuration PIN then 4~6 digit PIN+ ‘ENT’ to register for each subsequent User Access PIN at a time and then enter the 4~6 digit PIN+’ENT’ (Configuration PIN) to complete the registration.

(1) Apply 12V DC to the unit. All 3 LEDs will be flashing with a power-up melody. (2) Press ‘0’,’5’,’ENT’ from the keypad. (RF/PIN Combination Mode) (3) Present Master Card to register Master Card to the unit.

(4) The first 4~6 digit PIN becomes the Configuration PIN and the subsequent 4~6 digit PINs are registered as User Access PINs. Once all User Access PINs have been registered, enter the Configuration PIN again to complete the regis-tration. (Please store the Configuration PIN for future changes.)(5) Now, the Main Unit is entered into the normal operation mode with fac-tory defaulted settings.

(4) Present RF Card or enter 4~6 digit PIN number to register user access card or PIN.(5) Present Master Card to complete the registration

Please refer to Summary Table of Commands for configuring functions

Caution

Configuration PIN

User Access PIN

Configuration PIN again to complete the registration.

Master Card Master Card

User Access Cards or PINs

SSA-S2000 / S2000V Standalone ControllerStandalone Controller – SSA-S2000 / S2000V – Initial Setup

Proximity and PIN Access Controller

BACK

Page 47: Samsung Techwin Access Control Sales Presentation 2010

No Command Action/Change setting values No Command Action/Change setting values1 11 Add User Access Cards (RF CARD ONLY MODE) 31 48 Disable Unlock followed by Door Contact

2 12 Add User Access Cards and PIN (RF CARD + PIN MODE) 32 51 Disable Melody sound (turning off both the melody & key press audio feedback)

3 13 Add User Access PIN numbers (PIN ONLY MODE) 33 52 Enable Melody sound4 14 Delete User Access Cards (or PIN) 34 60 Change keypad lock-out time when Try-Out error detected5 15 Add User Access Card/PIN (RF/PIN Combination Mode) 35 61 Set Aux Input #1 Detection from ‘L’ to ‘H’

6 21 Change Door open time when User Access Card (or PIN) is granted 36 62 Set Aux Input #1 Detection from ‘H’ to ‘L’

7 22 Change Alarm time when User Access Card (or PIN) is denied 37 63 Set Aux Input #2 Detection from ‘L’ to ‘H’

8 23 Change Alarm time when Try-Out error detected 38 64 Set Aux Input #2 Detection from ‘H’ to ‘L’9 24 Change Alarm time when Door-Contact error detected 39 65 Set Aux Input #3 Detection from ‘L’ to ‘H’

10 25 Change Alarm time when Aux Input #1 detected 40 66 Set Aux Input #3 Detection from ‘H’ to ‘L’ 11 26 Change Alarm time when Aux Input #2 detected 41 67 Set Exit Button Input Detection from ‘L’ to ‘H’12 27 Change Alarm time when Aux Input #3 detected 42 68 Set Exit Button Input Detection from ‘H’ to ‘L’13 28 reserved 43 69 Set Door-Contact sensor Input Detection from ‘L’ to ‘H’ 14 29 Register 2 digits Duress Alarm password 44 70 Set Door-Contact sensor Input Detection from ‘H’ to ‘L’15 30 Change Alarm time when Duress Alarm detected 45 71 Activate TTL output to ‘H’16 31 Test Door open time set by command "21" 46 72 Activate TTL output to ‘L’17 32 Test Alarm time set by command "22" 47 73 Enable Keypad Input To Enter ID Number18 33 Test Alarm time set by command "23" 48 74 Disable Keypad Input To Enter ID Number19 34 Test Alarm time set by command "24" 49 77 Enable Chime Bell Output20 35 Test Alarm time set by command "25" 50 78 Disable Chime Bell Output21 36 Test Alarm time set by command "26" 51 80 Set delay time to activate SECURE MODE22 37 Test Alarm time set by command "27" 52 81 Set Door Open time-out for Door-Contact sensor23 39 Change Chime Bell activating time 53 82 Set number of times of Try-Out24 41 Open door unconditionally 54 83 Set input key press time-out time 25 42 Close door unconditionally 55 84 Set Tamper Alarm output port26 43 Enable QUICK ACCESS MODE 56 88 Enable Tamper Alarm27 44 Disable QUICK ACCESS MODE 57 89 Disable Tamper Alarm28 45 Enable Toggle Mode for Lock control 58 99 Re-Initialize and erase all setup data29 46 Disable Toggle Mode for Lock control30 47 Enable Unlock followed by Door Contact

Standalone Controller – SSA-S2000 / S2000V – Initial Setup

BACK

Page 48: Samsung Techwin Access Control Sales Presentation 2010

Standalone Controller – SSA-S2000 / S2000V – Technical Data

Proximity and PIN Access Controller

BACK

Page 49: Samsung Techwin Access Control Sales Presentation 2010

①②

③④

①②

SSA-S30xx Series SSA-S210x Series

LCD Display Keypad

Function keys LED

Indicators

Fingerprint scanner

LCD Display

Keypad

Function keys

LED Indicators

SSA-S30xx / SSA-S210x Standalone ControllerStandalone Controller – SSA-S30xx / S21xx Series – Panel Description

Finger Print Recognition, Proximity / Smart Card & PIN, Time and Attendance Access Controller

BACK

Page 50: Samsung Techwin Access Control Sales Presentation 2010

SSA-S30xx / SSA-S210x Standalone Controller

Door Contact

Management Software• Dedicated / Integrated

Exit Button

Door Lock

EXIT

Power+12V DCGND

Standalone Controller – SSA-S30xx / S21xx Series – Basic Installation

Finger Print Recognition, Proximity / Smart Card & PIN, Time and Attendance Access Controller

BACK

Page 51: Samsung Techwin Access Control Sales Presentation 2010

SSA-S30xx / SSA-S210x Standalone ControllerStandalone Controller – SSA-S30xx / S21xx Series – Network Diagram

Finger Print Recognition, Proximity / Smart Card & PIN, Time and Attendance Access Controller

BACK

Page 52: Samsung Techwin Access Control Sales Presentation 2010

Black -

Red +

Wiegand DATA 0 (Pink wire)Wiegand DATA 1 (Cyan wire)

Door contact

Exit Button

Black -

Red +Power : DC 12V(+)

SSA-S30xx / SSA-S210x Standalone Controller

• Door contact: Yellow with Red stripe wire & GND• Exit Button: Orange wire & GND• 2.2KΩ connection for cut-off checking

• Wiegand DATA 0 : Pink wire• Wiegand DATA 1 : Cyan wire

Standalone Controller – SSA-S30xx / S21xx Series – Connection Data

Finger Print Recognition, Proximity / Smart Card & PIN, Time and Attendance Access Controller

BACK

Page 53: Samsung Techwin Access Control Sales Presentation 2010

Door Re-lay

COM (Gray with white stripe wire ) NO ( White with Red stripe wire )

NC ( Blue with white strip wire )

Alarm Relay

COM ( White wire ) NO ( Purple ) NC ( Purple with white stripe wire )

Black -

Red +

SSA-S30xx / SSA-S210x Standalone ControllerSSA-S30xx / SSA-S210x Standalone ControllerStandalone Controller – SSA-S30xx / S21xx Series – Connection Data

Finger Print Recognition, Proximity / Smart Card & PIN, Time and Attendance Access Controller

BACK

Page 54: Samsung Techwin Access Control Sales Presentation 2010

Standalone Controller – SSA-S21XX Series – Technical Data

Proximity / Smart Card & PIN, Time and Attendance Access Controller

BACK

Page 55: Samsung Techwin Access Control Sales Presentation 2010

SSA-S30xx / SSA-S210x Standalone ControllerSSA-S30xx / SSA-S210x Standalone ControllerStandalone Controller – SSA-S30xx Series – Technical Data

Fingerprint Recognition, Proximity / Smart Card & PIN, Time and Attendance Access Controller

BACK

Page 56: Samsung Techwin Access Control Sales Presentation 2010

Reader• Card / Keypad / Biometric

Control Panel• RS485 / TCP/IP

Door Contact

EXIT

Management Software• Dedicated / Integrated

Exit Button

Door Lock

PowerAC 90~250V50/60Hz

SSA-P42xx / P40xx / P112x / P102x Control PanelIntelligent ControllersBasic Installation Diagram

BACK

Page 57: Samsung Techwin Access Control Sales Presentation 2010

SSA-P42xx / P40xx / P112x / P102x Control PanelIntelligent ControllersNetwork Configuration Diagram

BACK

Page 58: Samsung Techwin Access Control Sales Presentation 2010

Cross ConnectConverter to controllerTX(-) ↔ RX(-)TX(+) ↔ RX(+)RX(-) ↔ TX(-)RX(+) ↔ TX(+)

Direct ConnectController to controllerTX(-) ↔ TX(-)TX(+) ↔ TX(+)RX(-) ↔ RX(-)RX(+) ↔ RX(+)

SSA-P42xx / P40xx / P112x / P102x Control PanelIntelligent ControllersSerial Communications

BACK

Page 59: Samsung Techwin Access Control Sales Presentation 2010

SSA-P42xx / P40xx Control Panel

• Reader Power sources can be used separately, but GND has to be wired together. In the case of separate wiring , due to voltage level difference, communication error can be happened.

• All reader ports should be wired in the same way.

READER

DATA 0 (Green)

+12V (Red)

DATA 1 (White)

GND (Black)

EXIT

Exit Button

Intelligent Controllers SSA-P4XXConnection Diagram for Reader & Exit Button

BACK

Page 60: Samsung Techwin Access Control Sales Presentation 2010

Intelligent Controllers SSA-P4XXConnection Diagram for Door Lock

• Power Fail Secure - Power off Lock - Power on Unlock• Power Fail Safe - Power off Unlock - Power on Lock• Relay Output #1 & #3 are set up for door lock as default value

• In the case of Power off, if door is locked, the lock is called ‘Power Fail Secure Lock’.

Cathode Anode

1N4004 ~ 1N4007

BACK

Page 61: Samsung Techwin Access Control Sales Presentation 2010

• Separate power for readers can be also connected, but two power line should be connected to the same ground otherwise communication error may occur due to different level of voltage.

Reader #1

Reader #2

Intelligent Controllers SSA-P1XXConnection Diagram for Reader

BACK

Page 62: Samsung Techwin Access Control Sales Presentation 2010

Exit Button

Door Contact

• INPUT #1 is for Exit button and INPUT #2 is for Door Contact.

• #3 ~ #5 is user selectable.

EXIT

Intelligent Controllers SSA-P1XXConnection Diagram for Input

BACK

Page 63: Samsung Techwin Access Control Sales Presentation 2010

• According to lock activation mode, there are NO/NC types and wiring should be done accordingly.

• Using reverse diode is recommended to prevent electric surge when lock is activated.

Normal Open

Normal Close

Intelligent Controllers SSA-P1XX Connection Diagram for Door Lock l

BACK

Page 64: Samsung Techwin Access Control Sales Presentation 2010

Readers – R1000 / R1100 – Connection Data

BACK

Page 65: Samsung Techwin Access Control Sales Presentation 2010

Readers – R100X / R110X – Technical Data

BACK

Page 66: Samsung Techwin Access Control Sales Presentation 2010

Readers – R1000V / R1100V – Connection DataComprehensive range of readers to satisfy challenging security environments

BACK

Page 67: Samsung Techwin Access Control Sales Presentation 2010

Readers – R1000V / R1100V – Technical Data

BACK

Page 68: Samsung Techwin Access Control Sales Presentation 2010

Readers – R2000 – Connection DataComprehensive range of readers to satisfy challenging security environments

BACK

Page 69: Samsung Techwin Access Control Sales Presentation 2010

Readers – R2000 – Technical Data

BACK

Page 70: Samsung Techwin Access Control Sales Presentation 2010

Readers – R2000V – Connection DataComprehensive range of readers to satisfy challenging security environments

BACK

Page 71: Samsung Techwin Access Control Sales Presentation 2010

Readers – R2000V – Technical DataComprehensive range of readers to satisfy challenging security environments

BACK

Page 72: Samsung Techwin Access Control Sales Presentation 2010

SSA-R20xx Biometric Reader

• TCP/IP connection is only for the uploading / downloading the fingerprint data.

Readers – R2010 Series – Connection Data

BACK

Page 73: Samsung Techwin Access Control Sales Presentation 2010

Readers – R2010 Series – Technical DataComprehensive range of readers to satisfy challenging security environments

BACK

Page 74: Samsung Techwin Access Control Sales Presentation 2010

SAMS BasicSAMS Basic Lite

Application &Database

Access Controller(Hardware)

SAMS Basic Communication Server

SSA-P40x/SSA-P102SSA-S30xx/210x/SSA-R20xx

Communication Server

Database Server(Microsoft SQL Server 2005)

Serial Communication

TCP/IP

TCP/IP TCP/IP

TCP/IP

Software - Basic - ArchitectureSamsung Access Management Software

BACK

Page 75: Samsung Techwin Access Control Sales Presentation 2010

TCP/IP

TCP/IP or Serial

Loop

Database(MS SQL)

Application(SAMS Basic or

SAMS Basic Lite)

Comm. Server

Support up to10 Application

Support up to 10Comm. Server

Support up to 100 Loop

Support up to 32 Controller (if Serial Loop)

Support up to4 Door (if SSA-P42xx)

With one system(Database), support up to10 (Comm. Server) x 100 (Loop) x 1 (Controller) x 4 Doors =

4,000 Doors

Software – Basic - System ConfigurationSamsung Access Management Software

BACK

Page 76: Samsung Techwin Access Control Sales Presentation 2010

Branch Office #2 Branch Office #1

Head OfficeDatabase Server(MS SQL Server)

Serial Communication

SAMS BasicComm. Server

SAMS Basic(SSA-M1000)

SerialCommunication

Internet (Backbone, WAN)

TCP/IP Network (LAN)

TCP/IP Network(LAN)TCP/IP Network(LAN)

SSA-P112 SSA-P112 SSA-P112

SSA-P420T SSA-S3010 SSA-S2100

SAMS Basic Lite(SSA-M1100)

SAMS Basic Lite(SSA-M1100)

SAMS Basic(SSA-M1000)

SAMS Basic Lite(SSA-M1100)

SerialCommunication

SSA-P420

SSA-S3010 SSA-S2100

SSA-P112 SSA-P112

SSA-S3010 SSA-S2100

SAMS Basic Lite(SSA-M1100)

SAMS Basic(SSA-M1000)

SSA-P420

SAMS BasicComm. Server

SAMS BasicComm. Server

Software - BasicSamsung Access Management Software

BACK

Page 77: Samsung Techwin Access Control Sales Presentation 2010

SAMS Pro

SAMS Pro LiteApplication &

Database

Access Controller(Hardware)

SAMS Basic Communication Server

SSA-P40x/SSA-P102SSA-S30xx/210x/SSA-R20xx

Communication Server

Database Server(Microsoft SQL Server 2005)

Serial Communication

TCP/IP

TCP/IP TCP/IP

TCP/IP

DVR(SHR, SRD Series)TCP/IP

Software – Pro - ArchitectureSamsung Access Management Software

BACK

Page 78: Samsung Techwin Access Control Sales Presentation 2010

TCP/IP

TCP/IP or Serial

Loop

Database(MS SQL)

Application(SAMS Pro or

SAMS Pro Lite)

Comm. Server

Support up to10 Application

Support up to 10Comm. Server

Support up to 100 Loop

Support up to 32 Controller (if Serial Loop)

Support up to4 Door (if SSA-P42xx)

With one system(Database), support up to10 (Comm. Server) x 100 (Loop) x 1 (Controller) x 4 Doors =

4,000 Doors

No limitation withDVR Connection

Up to 8 video channel can be

monitored simultaneously

Software – Pro - ConfigurationSamsung Access Management Software

BACK

Page 79: Samsung Techwin Access Control Sales Presentation 2010

Branch Office #2 Branch Office #1

Head Office Database Server(MS SQL Server) SAMS Pro

Comm. ServerSerial

Communication

SAMS Pro(SSA-M2000)

SerialCommunication

Internet (Backbone, WAN)

SSA-P112 SSA-P112 SSA-P112

SSA-P420T SSA-S3010 SSA-S2100

SAMS Pro Lite(SSA-M2100)

SAMS Pro Lite(SSA-M2100)

SAMS Pro(SSA-M2000)

SAMS Pro Lite(SSA-M2100)

SerialCommunication

SSA-P112 SSA-P112

SSA-S3010 SSA-S2100

SSA-P112 SSA-P112

SSA-S3010 SSA-S2100

SAMS Pro Lite(SSA-M2100)

SAMS Pro(SSA-M2000)

SAMS ProComm. Server

TCP/IP Network (LAN)

TCP/IP Network(LAN)

CCTV System

CCTV System

SAMS ProComm. Server

CCTV System

TCP/IP Network(LAN)

Software – Pro - ConfigurationSamsung Access Management Software

BACK

Page 80: Samsung Techwin Access Control Sales Presentation 2010

END HERERest not used