san ramon, ca 94583 site name: el camino real cascade #: … el camino real - plans.pdf ·...

10
TITLE SHEET & PROJECT DATA T-1 100% ZDs T-16503-79 APE MTD BURLINGAME, CA 9410 1234 EL CAMINO REAL SF52XC160 El Camino Real 10/30/18 Plot Date:10/30/2018 4:41:34 PM File NameT:\2016\T-16503_Precision Site Development LLC\SF52XC160-79\SF52XC160\Sheets\Building A\T-1 Title Sheet & Project Data.dwg Plotted By:Anthony Erler REV DESCRIPTION DATE SHEET TITLE SHEET NUMBER CHECKED BY: DRAWN BY: PROJECT NO: IT IS A VIOLATION OF LAW FOR ANY PERSON, UNLESS THEY ARE ACTING UNDER THE DIRECTION OF A LICENSED PROFESSIONAL ENGINEER, TO ALTER THIS DOCUMENT. 1478 STONE POINT DRIVE, SUITE 350 ROSEVILLE CA 95661 TEL FAX borgesarch.com 916 782 7200 916 773 3037 San Ramon, CA 94583 12657 Alcosta Blvd., Suite 300 1524 RAINBOW TROUT STREET ROSEVILLE, CA 95747 A 10/03/18 100% ZD SUBMITTAL B 10/30/18 100% ZD REV 1 DRAWING INDEX SHEET NO: SHEET TITLE AREA MAP TITLE SHEET & PROJECT DATA T-1 OVERALL SITE PLAN A-1 A-2 EQUIPMENT DETAILS A-4 ENLARGED EQUIPMENT & ANTENNA PLANS SITE NAME: CASCADE #: SITE ADDRESS: SITE TYPE: EL CAMINO REAL SF52XC160 1234 EL CAMINO REAL ROOFTOP BURLINGAME, CA 9410 PROJECT NAME: DO MACRO DRIVING DIRECTIONS: 12657 ALCOSTA BLVD. SAN RAMON, CA, 94583 1. DEPART ALCOSTA BLVD TOWARD BISHOP RANCH FIFTEEN 2. TURN RIGHT ONTO BOLLINGER CANYON RD 3. TAKE RAMP RIGHT FOR I-680 SOUTH TOWARD SAN JOSE 4. TAKE RAMP RIGHT FOR I-580 WEST TOWARD DUBLIN / OAKLAND 5. KEEP LEFT ONTO I-238 N 6. AT EXIT 16A, TAKE RAMP RIGHT FOR I-880 SOUTH TOWARD SAN JOSE / SAN MATEO BR 7. AT EXIT 27, TAKE RAMP RIGHT FOR CA-92 WEST TOWARD SAN MATEO BR 8. TOLL ROAD 9. AT EXIT 13B, TAKE RAMP RIGHT FOR US-101 TOWARD SAN FRANCISCO / SAN JOSE 10. AT EXIT 419B, TAKE RAMP RIGHT AND FOLLOW SIGNS FOR BROADWAY 11. TURN RIGHT ONTO BAYSHORE HWY / OLD BAYSHORE HWY 12. TURN RIGHT ONTO BROADWAY 13. TURN RIGHT ONTO CA-82 / EL CAMINO REAL 14. ARRIVE AT CA-82 / EL CAMINO REAL 15. 1234 EL CAMINO REAL, BURLINGAME, CA ON RIGHT ELEVATIONS A-3.1 SITE APPLICABLE CODES ALL WORK AND MATERIALS SHALL BE PERFORMED AND INSTALLED IN ACCORDANCE WITH THE CURRENT EDITIONS OF THE FOLLOWING CODES AS ADOPTED BY THE LOCAL GOVERNING AUTHORITIES. NOTHING IN THESE PLANS IS TO BE CONSTRUED TO PERMIT WORK NOT CONFORMING TO THESE CODES. PROJECT DESCRIPTION SPECIAL INSPECTIONS NONE SITE INFORMATION 1) 2016 CALIFORNIA ADMINISTRATIVE CODE, CHAPTER 10, PART 1, TITLE 24 CODE OF REGULATIONS 2) 2016 CALIFORNIA BUILDING CODE (CBC) WITH CALIFORNIA AMENDMENTS, BASED ON THE 2015 IBC (PART 2, VOL 1-2) 3) 2016 CALIFORNIA RESIDENTIAL CODE (CRC) WITH APPENDIX H, PATIO COVERS, BASED ON THE 2015 IRC (PART 2.5) 4) 2016 CALIFORNIA GREEN BUILDINGS STANDARDS CODE (CALGREEN) (PART 11) (AFFECTED ENERGY PROVISIONS ONLY 5) 2016 CALIFORNIA FIRE CODE (CFC), BASED ON THE 2015 IFC, WITH CALIFORNIA AMENDMENTS (PART 9) 6) 2016 CALIFORNIA MECHANICAL CODE (CMC), BASED ON THE 2015 UMC (PART 4) 7) 2016 CALIFORNIA PLUMBING CODE (CPC), BASED ON THE 2015 UPC (PART 5) 8) 2016 CALIFORNIA ELECTRICAL CODE (CEC) WITH CALIFORNIA AMENDMENTS, BASED ON THE 2015 NEC (PART 3) 9) 2016 CALIFORNIA ENERGY CODE (CEC) 10) ANSI / EIA-TIA-222-H 11) 2015 NFPA 101, LIFE SAFETY CODE 12) 2016 NFPA 72, NATIONAL FIRE ALARM CODE 13) 2016 NFPA 13, FIRE SPRINKLER CODE PROPERTY OWNER: JFP LIMITED c/o BAYWOOD CAPITAL MANAGEMENT 330 PRIMROSE ROAD, SUITE 600 BURLINGAME, CA 94010 contact: Kelly Feist/Josh Turow ph: (650) 337-0700 SITE ADDRESS: 1234 EL CAMINO REAL BURLINGAME, CA 9410 EQUIPMENT SUPPLIER: SAMSUNG TELECOMMUNICATIONS AMERICA (STA) 1301 EAST LOOKOUT DRIVE RICHARDSON, TX 75082-4124 (972) 761-7000 COUNTY: SAN MATEO COUNTY ZONING JURISDICTION: CITY OF BURLINGAME ARCHITECT: BORGES ARCHITECTURAL GROUP, INC. 1478 STONE POINT DRIVE, SUITE 350 ROSEVILLE, CA 95661 contact: Matthew Dougherty ph: (916) 782-7200 email: [email protected] APN: 026-96-240 LATITUDE (NAD83): 37 35' 6.7488" N (35.5820833) LONGITUDE (NAD83): -122 22' 3.3378" W (-122.36759444) CONSTRUCTION MANAGER: SPRINT 12657 ALCOSTA BLVD, SUITE 300 SAN RAMON, CA 94583 contact: ERIC ANTONICK ph: (925) 852-9282 email: [email protected] DISABLED ACCESS REQUIREMENTS FACILITY IS UNMANNED AND NOT FOR HUMAN HABITATION, ACCESSIBILITY REQUIREMENTS ARE NOT REQUIRED, IN ACCORDANCE WITH CALIFORNIA BUILDING CODE, CODE OF REGULATIONS, TITLE 24, PART 2, VOLUME 1, CHAPTER 11B, DIVISION 2, SECTION 11B-203.5 GROUND ELEVATION: +/- 30' STRUCTURAL ENGINEER: PZSE 1478 STONE POINT DR. SUITE 190 ROSEVILLE, CA 95661 contact: PAUL ZACHER SE, MLSE ph: (916) 961-3960 POWER COMPANY: PG&E CORPORATION 1 MARKET STREET, SPEAR TOWER SAN FRANCISCO, CA 94105-1126 ph: (800) 743-5000 TELEPHONE COMPANY: AT&T CALIFORNIA 525 MARKET STREET SAN FRANCISCO, CA 94105 ph: (800) 310-2355 NOTE: NO PLUMBING ON SITE SITE ACQUISITION: PRECISION SITE DEVELOPMENT LLC 1524 RAINBOW TROUT STREET ROSEVILLE, CA 95747 contact: JEREMY JORDAN ph: (916) 918-9322 email: [email protected] ZONING MANAGER: PRECISION SITE DEVELOPMENT LLC 1524 RAINBOW TROUT STREET ROSEVILLE, CA 95747 contact: JEREMY JORDAN ph: (916) 918-9322 email: [email protected] APPLICANT: SPRINT 12657 ALCOSTA BLVD, SUITE 300 SAN RAMON, CA 94583 MODIFICATION TO EXISTING UNMANNED TELECOMMUNICATIONS FACILITY. 1. REMOVE (E) CLEARWIRE EQUIPMENT CABINET & ANTENNAS 2. REMOVE (E) CLEARWIRE EQUIPMENT PLATFORM AT ROOFTOP 3. INSTALL (1) RADIO CABINET 4. INSTALL (1) BBU CABINET 5. REPLACE (3) EXISTING PANEL ANTENNAS w/ (3) PROPOSED TRIBAND PANEL ANTENNAS 6. INSTALL (3) RRHS AT EACH OF SECTORS A, B, AND C 7. REMOVE (E) COAX AND REPLACE WITH (1) HYBRID PER SECTOR, (3) TOTAL ELEVATIONS A-3.2 ELEVATIONS A-3.3 ELEVATIONS A-3.4 EME-1 RF STUDY EME-2 EMERGENCY SIGNAGE

Upload: others

Post on 29-Jul-2020

0 views

Category:

Documents


0 download

TRANSCRIPT

Page 1: San Ramon, CA 94583 SITE NAME: EL CAMINO REAL CASCADE #: … El Camino Real - Plans.pdf · 2019-01-29 · EMERGENCY SIGNAGE EME-2 100% ZDs T-16503-79 APE MTD BURLINGAME, CA 9410 1234

TITLE SHEET &

PROJECT DATA

T-1

100% ZDs

T-16503-79

APE

MTD

BURLINGAME, CA 9410

1234 EL CAMINO REAL

SF52XC160

El Camino Real

10/30/18

Plot

Dat

e:10

/30/

2018

4:4

1:34

PM

F

ile N

ameT

:\20

16\T

-165

03_P

reci

sion

Site

Dev

elop

men

t LLC

\SF5

2XC

160-

79\S

F52X

C16

0\Sh

eets

\Bui

ldin

g A

\T-1

Titl

e Sh

eet &

Pro

ject

Dat

a.d

wg

Pl

otte

d B

y:A

ntho

ny E

rler

REV DESCRIPTIONDATE

SHEET TITLE

SHEET NUMBER

CHECKED BY:

DRAWN BY:

PROJECT NO:

IT IS A VIOLATION OF LAW FOR ANY

PERSON, UNLESS THEY ARE ACTING

UNDER THE DIRECTION OF A LICENSED

PROFESSIONAL ENGINEER, TO ALTER

THIS DOCUMENT.

1478 STONE POINT DRIVE, SUITE 350

ROSEVILLE CA 95661

TEL

FAX

borgesarch.com

916 782 7200

916 773 3037

San Ramon, CA 9458312657 Alcosta Blvd., Suite 300

1524 RAINBOW TROUT STREETROSEVILLE, CA 95747

A 10/03/18100% ZD SUBMITTAL

B 10/30/18 100% ZD REV 1

DRAWING INDEX

SHEET NO: SHEET TITLE

AREA MAP

TITLE SHEET & PROJECT DATAT-1

OVERALL SITE PLANA-1

A-2

EQUIPMENT DETAILSA-4

ENLARGED EQUIPMENT & ANTENNA PLANS

SITE NAME:

CASCADE #:

SITE ADDRESS:

SITE TYPE:

EL CAMINO REAL

SF52XC160

1234 EL CAMINO REAL

ROOFTOP

BURLINGAME, CA 9410

PROJECT NAME: DO MACRO

DRIVING DIRECTIONS: 12657 ALCOSTA BLVD. SAN RAMON, CA, 94583

1. DEPART ALCOSTA BLVD TOWARD BISHOP RANCH FIFTEEN

2. TURN RIGHT ONTO BOLLINGER CANYON RD

3. TAKE RAMP RIGHT FOR I-680 SOUTH TOWARD SAN JOSE

4. TAKE RAMP RIGHT FOR I-580 WEST TOWARD DUBLIN / OAKLAND

5. KEEP LEFT ONTO I-238 N

6. AT EXIT 16A, TAKE RAMP RIGHT FOR I-880 SOUTH TOWARD SAN JOSE / SAN MATEO BR

7. AT EXIT 27, TAKE RAMP RIGHT FOR CA-92 WEST TOWARD SAN MATEO BR

8. TOLL ROAD

9. AT EXIT 13B, TAKE RAMP RIGHT FOR US-101 TOWARD SAN FRANCISCO / SAN JOSE

10. AT EXIT 419B, TAKE RAMP RIGHT AND FOLLOW SIGNS FOR BROADWAY

11. TURN RIGHT ONTO BAYSHORE HWY / OLD BAYSHORE HWY

12. TURN RIGHT ONTO BROADWAY

13. TURN RIGHT ONTO CA-82 / EL CAMINO REAL

14. ARRIVE AT CA-82 / EL CAMINO REAL

15. 1234 EL CAMINO REAL, BURLINGAME, CA ON RIGHT

ELEVATIONSA-3.1

SITE

APPLICABLE CODES

ALL WORK AND MATERIALS SHALL BE PERFORMED AND INSTALLED IN

ACCORDANCE WITH THE CURRENT EDITIONS OF THE FOLLOWING

CODES AS ADOPTED BY THE LOCAL GOVERNING AUTHORITIES.

NOTHING IN THESE PLANS IS TO BE CONSTRUED TO PERMIT WORK

NOT CONFORMING TO THESE CODES.

PROJECT DESCRIPTION

SPECIAL INSPECTIONS

NONE

SITE INFORMATION

1) 2016 CALIFORNIA ADMINISTRATIVE CODE, CHAPTER 10, PART 1,

TITLE 24 CODE OF REGULATIONS

2) 2016 CALIFORNIA BUILDING CODE (CBC) WITH CALIFORNIA

AMENDMENTS, BASED ON THE 2015 IBC (PART 2, VOL 1-2)

3) 2016 CALIFORNIA RESIDENTIAL CODE (CRC) WITH APPENDIX H,

PATIO COVERS, BASED ON THE 2015 IRC (PART 2.5)

4) 2016 CALIFORNIA GREEN BUILDINGS STANDARDS CODE

(CALGREEN) (PART 11)

(AFFECTED ENERGY PROVISIONS ONLY

5) 2016 CALIFORNIA FIRE CODE (CFC), BASED ON THE 2015 IFC,

WITH CALIFORNIA AMENDMENTS (PART 9)

6) 2016 CALIFORNIA MECHANICAL CODE (CMC), BASED ON THE 2015

UMC (PART 4)

7) 2016 CALIFORNIA PLUMBING CODE (CPC), BASED ON THE 2015

UPC (PART 5)

8) 2016 CALIFORNIA ELECTRICAL CODE (CEC) WITH CALIFORNIA

AMENDMENTS, BASED ON THE 2015 NEC (PART 3)

9) 2016 CALIFORNIA ENERGY CODE (CEC)

10) ANSI / EIA-TIA-222-H

11) 2015 NFPA 101, LIFE SAFETY CODE

12) 2016 NFPA 72, NATIONAL FIRE ALARM CODE

13) 2016 NFPA 13, FIRE SPRINKLER CODE

PROPERTY OWNER:

JFP LIMITED

c/o BAYWOOD CAPITAL MANAGEMENT

330 PRIMROSE ROAD, SUITE 600

BURLINGAME, CA 94010

contact: Kelly Feist/Josh Turow

ph: (650) 337-0700

SITE ADDRESS:

1234 EL CAMINO REAL

BURLINGAME, CA 9410

EQUIPMENT SUPPLIER:

SAMSUNG TELECOMMUNICATIONS

AMERICA (STA)

1301 EAST LOOKOUT DRIVE

RICHARDSON, TX 75082-4124

(972) 761-7000

COUNTY:

SAN MATEO COUNTY

ZONING JURISDICTION:

CITY OF BURLINGAME

ARCHITECT:

BORGES ARCHITECTURAL GROUP, INC.

1478 STONE POINT DRIVE, SUITE 350

ROSEVILLE, CA 95661

contact: Matthew Dougherty

ph: (916) 782-7200

email: [email protected]

APN:

026-96-240

LATITUDE (NAD83):

37 35' 6.7488" N (35.5820833)

LONGITUDE (NAD83):

-122 22' 3.3378" W (-122.36759444)

CONSTRUCTION

MANAGER:

SPRINT

12657 ALCOSTA BLVD, SUITE 300

SAN RAMON, CA 94583

contact: ERIC ANTONICK

ph: (925) 852-9282

email: [email protected]

DISABLED ACCESS REQUIREMENTS

FACILITY IS UNMANNED AND NOT FOR HUMAN HABITATION,

ACCESSIBILITY REQUIREMENTS ARE NOT REQUIRED, IN ACCORDANCE

WITH CALIFORNIA BUILDING CODE, CODE OF REGULATIONS, TITLE 24,

PART 2, VOLUME 1, CHAPTER 11B, DIVISION 2, SECTION 11B-203.5

GROUND ELEVATION: +/- 30'

STRUCTURAL ENGINEER:

PZSE

1478 STONE POINT DR. SUITE 190

ROSEVILLE, CA 95661

contact: PAUL ZACHER SE, MLSE

ph: (916) 961-3960

POWER COMPANY:

PG&E CORPORATION

1 MARKET STREET, SPEAR TOWER

SAN FRANCISCO, CA 94105-1126

ph: (800) 743-5000

TELEPHONE COMPANY:

AT&T CALIFORNIA

525 MARKET STREET

SAN FRANCISCO, CA 94105

ph: (800) 310-2355

NOTE:

NO PLUMBING ON SITE

SITE ACQUISITION:

PRECISION SITE DEVELOPMENT

LLC

1524 RAINBOW TROUT STREET

ROSEVILLE, CA 95747

contact: JEREMY JORDAN

ph: (916) 918-9322

email: [email protected]

ZONING MANAGER:

PRECISION SITE DEVELOPMENT

LLC

1524 RAINBOW TROUT STREET

ROSEVILLE, CA 95747

contact: JEREMY JORDAN

ph: (916) 918-9322

email: [email protected]

APPLICANT:

SPRINT

12657 ALCOSTA BLVD, SUITE 300

SAN RAMON, CA 94583

MODIFICATION TO EXISTING UNMANNED TELECOMMUNICATIONS

FACILITY.

1. REMOVE (E) CLEARWIRE EQUIPMENT CABINET & ANTENNAS

2. REMOVE (E) CLEARWIRE EQUIPMENT PLATFORM AT ROOFTOP

3. INSTALL (1) RADIO CABINET

4. INSTALL (1) BBU CABINET

5. REPLACE (3) EXISTING PANEL ANTENNAS w/ (3) PROPOSED

TRIBAND PANEL ANTENNAS

6. INSTALL (3) RRHS AT EACH OF SECTORS A, B, AND C

7. REMOVE (E) COAX AND REPLACE WITH (1) HYBRID PER

SECTOR, (3) TOTAL

ELEVATIONSA-3.2

ELEVATIONSA-3.3

ELEVATIONSA-3.4

EME-1 RF STUDY

EME-2 EMERGENCY SIGNAGE

Page 2: San Ramon, CA 94583 SITE NAME: EL CAMINO REAL CASCADE #: … El Camino Real - Plans.pdf · 2019-01-29 · EMERGENCY SIGNAGE EME-2 100% ZDs T-16503-79 APE MTD BURLINGAME, CA 9410 1234

RF STUDY

EME-1

100% ZDs

T-16503-79

APE

MTD

BURLINGAME, CA 9410

1234 EL CAMINO REAL

SF52XC160

El Camino Real

10/30/18

Plot

Dat

e:10

/30/

2018

4:3

6:04

PM

F

ile N

ameT

:\20

16\T

-165

03_P

reci

sion

Site

Dev

elop

men

t LLC

\SF5

2XC

160-

79\S

F52X

C16

0\Sh

eets

\Bui

ldin

g A

\EM

E-1

RF S

tud

y.d

wg

Pl

otte

d B

y:A

ntho

ny E

rler

REV DESCRIPTIONDATE

SHEET TITLE

SHEET NUMBER

CHECKED BY:

DRAWN BY:

PROJECT NO:

IT IS A VIOLATION OF LAW FOR ANY

PERSON, UNLESS THEY ARE ACTING

UNDER THE DIRECTION OF A LICENSED

PROFESSIONAL ENGINEER, TO ALTER

THIS DOCUMENT.

1478 STONE POINT DRIVE, SUITE 350

ROSEVILLE CA 95661

TEL

FAX

borgesarch.com

916 782 7200

916 773 3037

San Ramon, CA 9458312657 Alcosta Blvd., Suite 300

1524 RAINBOW TROUT STREETROSEVILLE, CA 95747

A 10/03/18100% ZD SUBMITTAL

B 10/30/18 100% ZD REV 1

Page 3: San Ramon, CA 94583 SITE NAME: EL CAMINO REAL CASCADE #: … El Camino Real - Plans.pdf · 2019-01-29 · EMERGENCY SIGNAGE EME-2 100% ZDs T-16503-79 APE MTD BURLINGAME, CA 9410 1234

EMERGENCY

SIGNAGE

EME-2

100% ZDs

T-16503-79

APE

MTD

BURLINGAME, CA 9410

1234 EL CAMINO REAL

SF52XC160

El Camino Real

10/30/18

Plot

Dat

e:10

/30/

2018

4:3

6:15

PM

F

ile N

ameT

:\20

16\T

-165

03_P

reci

sion

Site

Dev

elop

men

t LLC

\SF5

2XC

160-

79\S

F52X

C16

0\Sh

eets

\Bui

ldin

g A

\EM

E-2

Emer

genc

y Si

gnag

e.d

wg

P

lotte

d B

y:A

ntho

ny E

rler

REV DESCRIPTIONDATE

SHEET TITLE

SHEET NUMBER

CHECKED BY:

DRAWN BY:

PROJECT NO:

IT IS A VIOLATION OF LAW FOR ANY

PERSON, UNLESS THEY ARE ACTING

UNDER THE DIRECTION OF A LICENSED

PROFESSIONAL ENGINEER, TO ALTER

THIS DOCUMENT.

1478 STONE POINT DRIVE, SUITE 350

ROSEVILLE CA 95661

TEL

FAX

borgesarch.com

916 782 7200

916 773 3037

San Ramon, CA 9458312657 Alcosta Blvd., Suite 300

1524 RAINBOW TROUT STREETROSEVILLE, CA 95747

A 10/03/18100% ZD SUBMITTAL

B 10/30/18 100% ZD REV 1

9

N.P.S

CAUTION SIGN

CAUTION

N.P.S

EMERGENCY SHUTDOWN SIGNAGE

EMERGENCY

FOR IMMEDIATE SHUT DOWN OF ALL RADIO

FREQUENCY EMISSIONS OF THIS SITE.

1) CALL CONTACT NUMBER AND GIVE SITE

IDENTIFICATION NO.:

CONTACT PHONE NUMBER:

1 (866) 400-6040, EXT. 5

SITE IDENTIFICATION NUMBER:

SF52XC160

2) DISCONNECT POWER AT MAIN SERVICE

DISCONNECT:

LOCATED IN SPRINT EQUIPMENT LEASE

AREA ON ROOFTOP

3) DISCONNECT BACK-UP POWER AT

BATTER DISCONNECT:

LOCATED IN SPRINT EQUIPMENT LEASE

AREA ON ROOFTOP

7

N.P.S

NOTICE SIGN

14

N.P.S

RF NOTICE GUIDELINES SIGN

NOTICE

Beyond This Point you are entering an

area where RF Emissions may exceed the FCC

General Population Exposure Limits

Maintain minimum of 9 feet clearance from

all antennas

DO NOT STOP IN FRONT OF ANTENNAS

Obey all posted signs and site guidelines

for working in an RF environment

NOTICE

GUIDELINES FOR WORKING IN

RADIOFREQUENCY ENVIRONMENTS

All personnel should have electromagnetic energy (EME)

awareness training.

All personnel entering this site must be authorized.

Obey all posted signs.

Assume all antennas are active

Before working on antennas, notify owners and disable appropriate

transmitters.

Maintain minimum 9 feet clearance from all antennas.

Do not stop in front of antennas.

Use personal rRF monitors while working near antennas.

Never operate transmitters without shields during normal operation.

Do not operate base station antennas in equipment room.

17

N.P.S

SIGNAGE AND STRIPING NOTES

1. THE FOLLOWING INFORMATION IS A GUIDELINE w/

RESPECT TO PREVAILING STANDARDS LIMITING HUMAN

EXPOSURE TO RADIO FREQUENCY ENERGY AND SHOULD BE

USED AS SUCH. IF THE SITE'S EMF REPORT OR ANY LOCAL,

STATE OR FEDERAL GUIDELINES OR REGULATIONS SHOULD

BE IN CONFLICT w/ ANY PART OF THESE NOTES OR PLANS,

THE MORE RESTRICTIVE GUIDELINE OR REGULATION SHALL

BE FOLLOWED AND OVERRIDE THE LESSER.

2. THE PUBLIC LIMIT OF RF EXPOSURE ALLOWED BY SPRINT

IS 1mWcm*2 AND THE OCCUPATIONAL LIMIT OF RF

EXPOSURE ALLOWED BY SPRINT IS 5mWcm*2

3. IF THE BOTTOM OF THE ANTENNA IS MOUNTED (8) EIGHT

FEET ABOVE THE GROUND OR WORKING PLATFORM LINE

OF THE PERSONAL COMMUNICATION SYSTEM (PCS) AND

DOES NOT EXCEED THE PUBLIC LIMIT OF RF EXPOSURE

LIMIT THEN NO STRIPING OR BARRICADES SHOULD BE

NEEDED.

4. IF THE PUBLIC LIMIT OF RF EXPOSURE ON THE SITE IS

EXCEEDED AND THE AREA IS PUBLICLY ACCESSIBLE (e.g.

ROOF ACCESS DOOR THAT CANNOT BE LOCKED, OR FIRE

EGRESS) THEN BOTH BARRICADES AND STRIPING SHALL BE

PLACED AROUND THE ANTENNAS. THE EXACT EXTENT OF

THE BARRICADES & STRIPING SHALL BE DETERMINED BY

THE EMF REPORT FOR THE SITE DONE BEFORE OR

SHORTLY AFTER COMPLETION OF SITE CONSTRUCTION.

USE THE PLANS AS A GUIDELINE FOR PLACEMENT OF SUCH

BARRICADES AND STRIPING.

5. ALL TRANSMIT ANTENNAS REQUIRE A THREE LANGUAGE

WARNING SIGN WRITTEN IN ENGLISH, SPANISH, AND

CHINESE. THIS SIGN SHALL BE PROVIDED TO THE

CONTRACTOR THE SPRINT CONSTRUCTION PROJECT

MANAGER AT THE TIME OF CONSTRUCTION. THE LARGER

SIGN SHALL BE PLACED IN PLAIN SIGHT AT ALL ROOF

ACCESS LOCATIONS AND ON ALL BARRICADES. THE

SMALLER SIGN SHALL BE PLACED ON THE ANTENNA

ENCLOSURES IN A MANNER THAT IS EASILY SEEN BY ANY

PERSON ON THE ROOF. WARNING SIGNS SHALL COMPLY w/

ANSI C95.2 COLOR, SYMBOL, AND CONTENT CONVENTIONS.

ALL SIGNS SHALL HAVE SPRINT'S NAME AND THE COMPANY

CONTACT INFORMATION (e.g. TELEPHONE NUMBER) TO

ARRANGE FOR ACCESS TO THE RESTRICTED AREAS. THIS

TELEPHONE NUMBER SHALL BE PROVIDED TO THE

CONTRACTOR BY SPRINT CONSTRUCTION PROJECT

MANAGER AT THE TIME OF CONSTRUCTION.

6. PHOTOS OF ALL STRIPING, BARRICADES & SIGNAGE SHALL

BE PART OF THE CONTRACTORS CLOSE OUT PACKAGE &

SHALL BE TURNED INTO THE SPRINT CONSTRUCTION

PACKAGE & SHALL BE TURNED INTO THE SPRINT

CONSTRUCTION PROJECT MANAGER AT THE END OF

CONSTRUCTION. STRIPING SHALL BE DONE w/ FADE

RESISTANT YELLOW SAFETY PAINT IN A CROSS-HATCH

PATTERN AS DETAILED BY THE CONSTRUCTION DRAWINGS.

ALL BARRICADES SHALL BE MADE OF AN RF FRIENDLY

MATERIAL SO AS NOT TO BLOCK OR INTERFERE w/ THE

OPERATION OF THE ANTENNAS. BARRICADES SHALL BE

PAINTED w/ FADE RESTRAINT YELLOW SAFETY PAINT. THE

CONTRACTOR SHALL PROVIDE ALL RF FRIENDLY

BARRICADES NEEDED, & SHALL PROVIDE THE SPRINT

CONSTRUCTION PROJECT MANAGER w/ A DETAILED SHOP

DRAWING OF EACH BARRICADE. UPON CONSTRUCTION

COMPLETION.

SIGNAGE AND STRIPING INFORMATION

NOTE: SIGN SHALL BE PERMANENTLY

MOUNTED AT ANTENNA LOCATIONS.

TO BE INSTALLED ON ROOF ENTRY POINT

GERAL NOTES

1. SIGN SHALL BE PERMANENTLY MOUNTED TO DOOR OF PPC CABINET

2. SIGN SHALL BE A PHENOLIC LABEL WITH WHITE BACKGROUND AND

BLACK LETTERING. THE TITLE BLOCK SHALL BE A RED BACKGROUND

AND 1" HIGH WHITE LETTERING.

3. CONTRACTOR TO PLACE SIGNS IN THE FOLLOWING LOCATIONS:

A. CELL SITE EQUIPMENT ROOM DOOR.

B. BATTERY LOCATION WITHIN PROXIMITY OF BATTERY

DISCONNECT.

C. FCC ROOM WITHIN PROXIMITY OF THE FIRE ALARM PANEL.

D. BUILDING'S MAIN ELECTRICAL ROOM WITHIN PROXIMITY OF THE

MAIN SHUTOFF AND/OR AT THE CELL SITE MAIN ELECTRICAL

DISCONNECT.

15

N.P.S

4"X4" CAMOUFLAGED ANTENNA SIGN

5

4"X4" SIGNAGE NOTE

4"X4" WARNING SIGN SHALL BE

PERMANENTLY MOUNTED TO EXTERIOR OF

CAMOUFLAGED ANTENNAS RF SCREENS.

Ref: FCC 47CFR 1.1130(b)

SITE NO. SF52XC160

Beyond This Point you are entering a

controlled area where RF Emissions may exceed

the FCC Controlled Exposure Limits

Maintain minimum of 9 feet clearance from

all antennas

DO NOT STOP IN FRONT OF ANTENNAS

Obey all posted signs and site guidelines

for working in an RF environment

Ref: FCC 47CFR 1.1130(b)

SITE NO. SF52XC160

NOTE: SIGN SHALL BE PERMANENTLY

MOUNTED AT ANTENNA LOCATIONS.

SPRINT OPERATES TELECOMMUNICATION ANTENNAS AT THIS

LOCATION. REMAIN AT LEAST 9 FEET AWAY FROM ANY

ANTENNA AND OBEY ALL POSTED SIGNS.

CONTACT THE OWNER(S) OF THE ANTENNA(S) BEFORE

WORKING CLOSER THAN 9 FEET FROM THE ANTENNA(S)

CONTACT SPRINT AT 1-866-400-6040 PRIOR TO PERFORMING

ANY MAINTENANCE OR REPAIRS NEAR SPRINT ANTENNAS.

THIS IS SPRINT SITE # SF52XC160

CONTACT THE MANAGEMENT OFFICE IF THIS

DOOR/HATCH/GATE IS FOUND UNLOCKED.

EN ESTA PROPIEDAD SE UBICAN ANTENAS DE TELECOMUNICACIM

ONES OPERADAS POR SPRINT. FAVOR MANTENER UNA DISTANCIA

DE NO MENOS DE 9 PIES Y OBEDECER TODOS LOS AVISOS.

COMUNIQUESE CON EL PROPIETARIO O LOS PROPIETARIOS DE

LAS ANTENAS ANTES DE TRABAJAR O CAMINAR DE MENOS DE 9

PIES DE LA ANTENA.

COMUNIQUESE CON SPRINT 1-866-400-6040 ANTES DE REALIZAR

CUALQUIER MANTENIMIENTO O REPARACION DE LAS ANTENAS DE

SPRINT.

ESTA ES LA ESTACION BASE NUMERO SF52XC160

FAVOR COMINUCARSE CON LA OFICINA DE LA ADMINISTRACION

DEL EDIFICIO SI ESTA PUENTA O COMPUERTA SE ENCUENTRA SIN

CANDADO.

INFORMATION

INFORMACION

NOTE: SIGN SHALL BE PERMANANTLY

MOUNTED TO STAIRWELL SIDE OF

THE ROOF ACCESS

N.P.S

EMF/RF INFORMATION SIGN

1

47 CFR1.1310

1 (866) 400-6040, EXT. 5

NOTICE TO WORKERS

RADIO FREQUENCY ANTENNAS ON THIS ROOF.

PLEASE EXERCISE CAUTION AROUND ANTENNAS AND OBEY

POSTED SIGNS AND/OR MARKINGS. FOR ACCESS TO

RESTRICTED AREAS OR FOR FURTHER INFORMATION,

PLEASE CALL 1 (866) 400-6040, EXT. 5

(SITE NUMBER SF52XC160)

AVISO A TRABAJADORES

IN ACCORDANCE WITH FCC RULES 47 CFR 1.1310

DE ACUERDO A LAS REGLAS DE FCC 47 CFR 1.130

EXISTEN ANTENAS DE RADIOFREQUENCIA EN ESTE TECHO.

POR FAVOR USE PRECAUCION ALREDOR DE LAS ANTENAS Y

OBEDEZCA A LAS ZONAS RESTRINGIDAS O PARA OBTENER

MAS INFORMACION, LLAME AL TELEFONO 1 (866) 400-6040,

EXT. 5 (NUMERO DE SITIO SF52XC160)

FCC

STAY BACK __9__ FEET

FROM ANTENNA!

SF52XC160

MANTENGASE A __9__ PIES

DE LA ANTENA!

!9

N.P.S

MULTI-LANGUAGE SIGN

3

SHUT DOWN

Page 4: San Ramon, CA 94583 SITE NAME: EL CAMINO REAL CASCADE #: … El Camino Real - Plans.pdf · 2019-01-29 · EMERGENCY SIGNAGE EME-2 100% ZDs T-16503-79 APE MTD BURLINGAME, CA 9410 1234

17

1" = 10'-0"

OVERALL SITE PLAN

E

L

C

A

M

I

N

O

R

E

A

L

(E) SOLAR

PANELS

ROOF

DECK

A-2

17

A-2

19

S

H

E

R

M

A

N

A

V

E

(E) BUILDING

(E) BUILDING

(E) BUILDING

(E) BUILDING

(E) BUILDING

(E) BUILDING

(E) BUILDING

(E) BUILDING

(E) BUILDING

(E) BUILDING

(E) BUILDING

P

R

O

P

E

R

T

Y

B

O

U

N

D

A

R

Y

P

R

O

P

E

R

T

Y

B

O

U

N

D

A

R

Y

P

R

O

P

E

R

T

Y

B

O

U

N

D

A

R

Y

P

R

O

P

E

R

T

Y

B

O

U

N

D

A

R

Y

(E) SOLAR

PANELS

(E) SOLAR

PANELS

EXISTING EQUIPMENT &

SECTOR A & C ANTENNA PLAN

S

E

C

T

O

R

A

Z

I

M

U

T

H

2

4

0

C

S

E

C

T

O

R

A

Z

I

M

U

T

H

1

2

0

B

SE

CT

OR

AZ

IM

UT

H 0

A

A-3.3

17

A-3.1

17

ROOF ACCESS

EXISTING ANTENNA LAYOUT-

SECTOR B

A-2

9

PROPOSED EQUIPMENT &

SECTOR C ANTENNA PLAN

A-2

11

PROPOSED ANTENNA LAYOUT-

SECTORS A & B

A-3.4

17

A-3.2

17

(P) 1'-0" CABLE

TRAY ON SLEEPERS

(P) YELLOW CAUTION

SIGNAGE PER EME-1

(P) BLUE NOTICE

SIGNAGE PER EME-1

(P) BLUE NOTICE

SIGNAGE PER EME-1

(P) STRIPING WITH BLUE

PAINT PER EME-1

(P) STRIPING WITH

YELLOW PAINT PER EME-1

(P) STRIPING WITH BLUE

PAINT PER EME-1

(P) STRIPING WITH

YELLOW PAINT PER EME-1

(P) YELLOW CAUTION

SIGNAGE PER EME-1

(P) STRIPING WITH BLUE

PAINT PER EME-1

(P) STRIPING WITH

YELLOW PAINT PER EME-1

(P) YELLOW CAUTION

SIGNAGE PER EME-1

(P) BLUE NOTICE

SIGNAGE PER EME-1

(P) BLUE NOTICE

SIGNAGE PER EME-1

OVERALL SITE PLAN

A-1

100% ZDs

T-16503-79

APE

MTD

BURLINGAME, CA 9410

1234 EL CAMINO REAL

SF52XC160

El Camino Real

10/30/18

Plot

Dat

e:10

/30/

2018

4:3

6:22

PM

F

ile N

ameT

:\20

16\T

-165

03_P

reci

sion

Site

Dev

elop

men

t LLC

\SF5

2XC

160-

79\S

F52X

C16

0\Sh

eets

\Bui

ldin

g A

\A-1

Ove

rall S

ite P

lan.

dw

g

Plot

ted

By:

Ant

hony

Erle

r

REV DESCRIPTIONDATE

SHEET TITLE

SHEET NUMBER

CHECKED BY:

DRAWN BY:

PROJECT NO:

IT IS A VIOLATION OF LAW FOR ANY

PERSON, UNLESS THEY ARE ACTING

UNDER THE DIRECTION OF A LICENSED

PROFESSIONAL ENGINEER, TO ALTER

THIS DOCUMENT.

1478 STONE POINT DRIVE, SUITE 350

ROSEVILLE CA 95661

TEL

FAX

borgesarch.com

916 782 7200

916 773 3037

San Ramon, CA 9458312657 Alcosta Blvd., Suite 300

1524 RAINBOW TROUT STREETROSEVILLE, CA 95747

A 10/03/18100% ZD SUBMITTAL

B 10/30/18 100% ZD REV 1

10' 5' 10' 20'

1"=10'-0"

N

Page 5: San Ramon, CA 94583 SITE NAME: EL CAMINO REAL CASCADE #: … El Camino Real - Plans.pdf · 2019-01-29 · EMERGENCY SIGNAGE EME-2 100% ZDs T-16503-79 APE MTD BURLINGAME, CA 9410 1234

1

1/2" = 1'-0"

ANTENNA SCHEDULE

SECTOR

A

L

P

H

A

B

E

T

A

ANTENNA MODEL NO. AZIMUTHRAD CENTER

ANTENNA SCHEDULE

0° 40'-0"

120°

A1

B1

G

A

M

M

A

240°C1

CCI TPA65R-KE4DA-K

40'-0"

40'-0"

CCI TPA65R-KE4DA-K

CCI TPA65R-KE4DA-K

17

3/8" = 1'-0"

EXISTING EQUIPMENT & SECTOR A & C ANTENNA PLAN

(E) CLEARWIRE ANTENNA &

RRH TO BE REMOVED

(E) STEALTH SCREEN BOX

TO REMAIN

(E) PENTHOUSE

(E) ROOF ACCESS DOOR

(E) ROOF

DECK

(E) CLEARWIRE ANTENNA

& RRH TO BE REMOVED

(E) CLEARWIRE

EQUIPMENT CABINET

TO BE REMOVED

(E) EQUIPMENT

CURB TO BE

REMOVED

(E) ELECTRICAL EQUIPMENT

AT LOWER LEVEL GARAGE

(E) STEALTH SCREEN BOX

(E) FIBER BOX, TO REMAIN

(

P

)

1

0

'

-

0

"

S

P

R

I

N

T

L

E

A

S

E

A

R

E

A

9

3/8" = 1'-0"

PROPOSED EQUIPMENT & SECTOR C ANTENNA PLAN

(E) ROOF

DECK

(E) PENTHOUSE

(P) SPRINT TRIBAND ANTENNA

MOUNTED (E) ANTENNA PIPE

(

P

)

4

'

-

4

"

R

A

I

S

E

D

P

L

A

T

F

O

R

M

(E) & (P) ELECTRICAL EQUIPMENT

AT LOWER LEVEL GARAGE

(P) RAISED PLATFORM

(

P

)

1

0

'

-

0

"

S

P

R

I

N

T

L

E

A

S

E

A

R

E

A

&

R

A

I

S

E

D

P

L

A

T

F

O

R

M

(P) 200 AMP PPC

ATTACHED TO H-FRAME

S

E

C

T

O

R

A

Z

I

M

U

T

H

2

4

0

C

(P) SPRINT CABINETS -

ECAB / ICAB / BCAB

(P) CABLE TRAY ON

SLEEPERS

(E) STEALTH SCREEN BOX

(P) SPRINT 2.5 RRH MOUNTED

ON (P) UNISTRUT ON (E) WALL

(P) 10'-0" x 10'-0" SPRINT

LEASE AREA

TOTAL = 100 SQ. FT.

(P) YELLOW CAUTION

SIGNAGE PER EME-1

(P) CAMOUFLAGED

ANTENNA SIGNAGE

(P) CAMOUFLAGED

ANTENNA SIGNAGE

(P) BLUE NOTICE, GREEN

INFORMATION, AND

MULTI-LANGUAGE SIGNAGE

POSTED ON (E) ACCESS DOOR

(P) EMERGENCY SHUTDOWN

SIGNAGE ON (P) PPC AND (P)

ELTEK CABINET

19

1/2" = 1'-0"

EXISTING ANTENNA LAYOUT- SECTOR B

(E) MICROWAVE TO REMAIN

(E) STEALTH SCREEN

ANTENNA ENCLOSURE

(E) ANTENNA AND RRH

TO BE REMOVED

(E) STEALTH SCREEN ANTENNA

ENCLOSURE ACCESS DOOR

AZ

IM

UT

H 0

MIC

RO

WA

VE

11

1/2" = 1'-0"

PROPOSED ANTENNA LAYOUT- SECTORS A & B

(P) SPRINT TRIBAND ANTENNA MOUNTED ON

(P) ANTENNA PIPE ATTACHED TO STEALTH

FRAME

(P) SPRINT 4 PORT 800 RRH & 1900 RRH

MOUNTED ON (P) ANTENNA PIPE

MOUNTED TO STEALTH FRAME

(P) SPRINT 4 PORT 800 RRH & 1900 RRH

MOUNTED ON (P) ANTENNA PIPE

MOUNTED TO STEALTH FRAME

S

E

C

T

O

R

A

Z

I

M

U

T

H

1

2

0

B

AZ

IM

UT

H 0

SE

CT

OR

AZ

IM

UT

H 0

A

MIC

RO

WA

VE

(P) (3) HYBRID CABLES,

IN (P) CABLE TRAY

(P) SLEEPER TRAY

SUPPORT, EVERY 4' O.C.

(P) 1'-0" CABLE TRAY

MOUNTED ON SLEEPERS

(P) SPRINT TRIBAND ANTENNA MOUNTED ON

(P) ANTENNA PIPE ATTACHED TO STEALTH

FRAME

(P) SPRINT 2.5 RRH MOUNTED ON (P)

ANTENNA PIPE MOUNTED TO STEALTH

FRAME

(P) YELLOW CAUTION

SIGNAGE PER EME-1

(P) YELLOW CAUTION

SIGNAGE PER EME-1

(P) CAMOUFLAGED

ANTENNA SIGNAGE

(P) CAMOUFLAGED

ANTENNA SIGNAGE

(P) CAMOUFLAGED

ANTENNA SIGNAGE

ENLARGED EQUIPMENT

& ANTENNA PLANS

A-2

100% ZDs

T-16503-79

APE

MTD

BURLINGAME, CA 9410

1234 EL CAMINO REAL

SF52XC160

El Camino Real

10/30/18

Plot

Dat

e:10

/30/

2018

4:3

6:38

PM

F

ile N

ameT

:\20

16\T

-165

03_P

reci

sion

Site

Dev

elop

men

t LLC

\SF5

2XC

160-

79\S

F52X

C16

0\Sh

eets

\Bui

ldin

g A

\A-2

Enl

arge

d E

quip

men

t & A

nten

na P

lans

.dw

g

Plo

tted

By:

Ant

hony

Erle

r

REV DESCRIPTIONDATE

SHEET TITLE

SHEET NUMBER

CHECKED BY:

DRAWN BY:

PROJECT NO:

IT IS A VIOLATION OF LAW FOR ANY

PERSON, UNLESS THEY ARE ACTING

UNDER THE DIRECTION OF A LICENSED

PROFESSIONAL ENGINEER, TO ALTER

THIS DOCUMENT.

1478 STONE POINT DRIVE, SUITE 350

ROSEVILLE CA 95661

TEL

FAX

borgesarch.com

916 782 7200

916 773 3037

San Ramon, CA 9458312657 Alcosta Blvd., Suite 300

1524 RAINBOW TROUT STREETROSEVILLE, CA 95747

A 10/03/18100% ZD SUBMITTAL

B 10/30/18 100% ZD REV 1

GRAPHICS LEGEND

FENCE:

WOOD/IRON FENCE:

LEASE AREA:

POWER:

TELCO:

HYBRID:

X X X

ICE BRIDGE:

CABLE TRAY:

WALL/PARTITION:

BBU: BATTERY BACKUP UNIT

CAB: CABINET

CDMA: CODE DIVISION MULTIPLE ACCESS

CMU: CONCRETE MASONRY UNIT

(E): EXISTING

GND: GROUND

GPS: GLOBAL POSITIONING SYSTEM

HVAC: HEATING VENTILATION AIR CONDITIONING

HYB: HYBRID LINE

MMBS: MULTI MODAL BASE STATION

(N): NEW

(P): PROPOSED

PPC: POWER PROTECTION UNIT

PRI: LEGACY PRIMARY CABINET

PWR: POWER

RAD: RADIATION CENTER

RET: REMOTE ELECTRICAL TILT

RF: RADIO FREQUENCY

RFP: REINFORCED FIBERGLASS PANEL

RRU: REMOTE RADIO UNIT

TEL: TELCO

HFC: HYDROGEN FUEL CELL

HSM: HYDROGEN STORAGE MODULE

NOTES

1. CONDUIT ROUTING IS DIAGRAMMATICALLY SHOWN ON PLANS AND ARE

ONLY APPROXIMATIONS. THE EXACT LOCATION AND ROUTING SHALL BE

FIELD VERIFIED.

2. ALL ELECTRICAL EQUIPMENT AND CONTROLLING DEVICES SHALL BE

PROVIDED WITH LAMI COLD NAMEPLATES, INDICATING THE CIRCUITS

ORIGINATION AND ALL EQUIPMENT TERMINATIONS

3. CONTRACTOR SHALL SUPPLY BREAKERS, CONDUITS AND CIRCUIT

CONDUCTORS, AS REQUIRED FOR A COMPLETED SYSTEM AND SHALL BE IN

COMPLIANCE WITH MANUFACTURER SPECIFICATIONS.

Pwr Pwr Pwr

Tel Tel Tel

Hyb Hyb Hyb

ACRONYM LEGEND

1/2"=1'-0"

1'2' 2' 4'

N

1/2"=1'-0"

1'2' 2' 4'

N

4' 2' 4' 8'0

3/8"=1'-0"

4' 2' 4' 8'0

3/8"=1'-0"

NN

Page 6: San Ramon, CA 94583 SITE NAME: EL CAMINO REAL CASCADE #: … El Camino Real - Plans.pdf · 2019-01-29 · EMERGENCY SIGNAGE EME-2 100% ZDs T-16503-79 APE MTD BURLINGAME, CA 9410 1234

17

1/4" = 1'-0"

EXISTING NORTHWEST ELEVATION

TOP OF (E) BUILDING

±33'-0" A.G.L.

TOP OF (E) PENTHOUSE STEALTH SCREEEN

±42'-0" A.G.L.

RAD CENTER OF (E) CLEARWIRE MICROWAVE DISHES

±40'-8" A.G.L.

GROUND LEVEL

0'-0"

(E) BUILDING

(E) MICROWAVE TO REMAIN

(E) ANTENNA AND RRH

TO BE REMOVED

(E) STEALTH SCREEN

ANTENNA ENCLOSURE

(E) PENTHOUSE

(E) ANTENNA AND RRH

TO BE REMOVED

(E) STEALTH SCREEN BOX

(E) CLEARWIRE EQUIPMENT

CABINET TO BE REMOVED

(E) ANTENNA AND RRH

TO BE REMOVED

(E) STEALTH SCREEN

BOX TO REMAIN

TOP OF (E) EQUIPMENT CABINET

±38'-5" A.G.L.

ELEVATIONS

A-3.1

100% ZDs

T-16503-79

APE

MTD

BURLINGAME, CA 9410

1234 EL CAMINO REAL

SF52XC160

El Camino Real

10/30/18

Plot

Dat

e:10

/30/

2018

4:3

6:50

PM

F

ile N

ameT

:\20

16\T

-165

03_P

reci

sion

Site

Dev

elop

men

t LLC

\SF5

2XC

160-

79\S

F52X

C16

0\Sh

eets

\Bui

ldin

g A

\A-3

.1 E

LEV

ATIO

NS.

dw

g

Plot

ted

By:

Ant

hony

Erle

r

REV DESCRIPTIONDATE

SHEET TITLE

SHEET NUMBER

CHECKED BY:

DRAWN BY:

PROJECT NO:

IT IS A VIOLATION OF LAW FOR ANY

PERSON, UNLESS THEY ARE ACTING

UNDER THE DIRECTION OF A LICENSED

PROFESSIONAL ENGINEER, TO ALTER

THIS DOCUMENT.

1478 STONE POINT DRIVE, SUITE 350

ROSEVILLE CA 95661

TEL

FAX

borgesarch.com

916 782 7200

916 773 3037

San Ramon, CA 9458312657 Alcosta Blvd., Suite 300

1524 RAINBOW TROUT STREETROSEVILLE, CA 95747

A 10/03/18100% ZD SUBMITTAL

B 10/30/18 100% ZD REV 1

1/4"=1'-0"

2'4' 4' 8'

Page 7: San Ramon, CA 94583 SITE NAME: EL CAMINO REAL CASCADE #: … El Camino Real - Plans.pdf · 2019-01-29 · EMERGENCY SIGNAGE EME-2 100% ZDs T-16503-79 APE MTD BURLINGAME, CA 9410 1234

17

1/4" = 1'-0"

PROPOSED NORTHWEST ELEVATION

(E) MICROWAVE

TOP OF (E) BUILDING

±33'-0" A.G.L.

TOP OF (E) PENTHOUSE STEATH TOWER

±42'-0" A.G.L.

RAD CENTER OF (E) CLEARWIRE MICROWAVE DISHES

±40'-8" A.G.L.

RAD CENTER OF (P) SPRINT ANTENNAS

±39'-0" A.G.L.

NOTE:

SECTOR B NOT SHOWN FOR CLARITY

(P) SPRINT

RADIO CABINET

(E) STEALTH SCREEN BOX

(P) SPRINT 4 PORT 800 RRH & 1900

RRH MOUNTED ON (P) ANTENNA PIPE

(E) PENTHOUSE

(P) RAISED PLATFORM

(E) BUILDING

(E) STEALTH SCREEN

ANTENNA ENCLOSURE

(P) 1900 RRH MOUNTED ON

(P) ANTENNA PIPE

(P) SPRINT 4 PORT 800 RRH

MOUNTED ON (P) ANTENNA PIPE

(P) SPRINT TRIBAND ANTENNA

MOUNTED (P) ANTENNA PIPE

(P) SPRINT TRIBAND ANTENNA

MOUNTED (P) ANTENNA PIPE

GROUND LEVEL

0'-0"

(P) SPRINT 2.5 RRH MOUNTED

ON (P) ANTENNA PIPE

(E) STEALTH SCREEN BOX

TOP OF (P) EQUIPMENT CABINET

±39'-3" A.G.L.

(P) SPRINT 2.5 RRH MOUNTED ON (P) UNISTRUT

ON (E) PENTHOUSE WALL (BEYOND)

ELEVATIONS

A-3.2

100% ZDs

T-16503-79

APE

MTD

BURLINGAME, CA 9410

1234 EL CAMINO REAL

SF52XC160

El Camino Real

10/30/18

Plot

Dat

e:10

/30/

2018

4:3

7:00

PM

F

ile N

ameT

:\20

16\T

-165

03_P

reci

sion

Site

Dev

elop

men

t LLC

\SF5

2XC

160-

79\S

F52X

C16

0\Sh

eets

\Bui

ldin

g A

\A-3

.2 E

LEV

ATIO

NS.

dw

g

Plot

ted

By:

Ant

hony

Erle

r

REV DESCRIPTIONDATE

SHEET TITLE

SHEET NUMBER

CHECKED BY:

DRAWN BY:

PROJECT NO:

IT IS A VIOLATION OF LAW FOR ANY

PERSON, UNLESS THEY ARE ACTING

UNDER THE DIRECTION OF A LICENSED

PROFESSIONAL ENGINEER, TO ALTER

THIS DOCUMENT.

1478 STONE POINT DRIVE, SUITE 350

ROSEVILLE CA 95661

TEL

FAX

borgesarch.com

916 782 7200

916 773 3037

San Ramon, CA 9458312657 Alcosta Blvd., Suite 300

1524 RAINBOW TROUT STREETROSEVILLE, CA 95747

A 10/03/18100% ZD SUBMITTAL

B 10/30/18 100% ZD REV 1

1/4"=1'-0"

2'4' 4' 8'

Page 8: San Ramon, CA 94583 SITE NAME: EL CAMINO REAL CASCADE #: … El Camino Real - Plans.pdf · 2019-01-29 · EMERGENCY SIGNAGE EME-2 100% ZDs T-16503-79 APE MTD BURLINGAME, CA 9410 1234

17

1/4" = 1'-0"

EXISTING SOUTHWEST ELEVATION

TOP OF (E) BUILDING

±33'-0" A.G.L.

GROUND LEVEL

0'-0"

(E) MICROWAVE TO REMAIN

(E) STEALTH SCREEN

ANTENNA ENCLOSURE

(E) ANTENNA

AND RRH TO

BE REMOVED

(E) BUILDING

(E) PENTHOUSE

(E) CLEARWIRE

EQUIPMENT

CABINET TO

BE REMOVED

TOP OF (E) PENTHOUSE STEALTH SCREEN

±42'-0" A.G.L.

RAD CENTER OF (E) CLEARWIRE MICROWAVE DISHES

±40'-8" A.G.L.

Existing Southwest Elevation

(E) ANTENNA AND RRH

TO BE REMOVED

(E) STEALTH SCREEN BOX

TOP OF (E) EQUIPMENT CABINET

±38'-5" A.G.L.

ELEVATIONS

A-3.3

100% ZDs

T-16503-79

APE

MTD

BURLINGAME, CA 9410

1234 EL CAMINO REAL

SF52XC160

El Camino Real

10/30/18

Plot

Dat

e:10

/30/

2018

4:3

7:10

PM

F

ile N

ameT

:\20

16\T

-165

03_P

reci

sion

Site

Dev

elop

men

t LLC

\SF5

2XC

160-

79\S

F52X

C16

0\Sh

eets

\Bui

ldin

g A

\A-3

.3 E

LEV

ATIO

NS.

dw

g

Plot

ted

By:

Ant

hony

Erle

r

REV DESCRIPTIONDATE

SHEET TITLE

SHEET NUMBER

CHECKED BY:

DRAWN BY:

PROJECT NO:

IT IS A VIOLATION OF LAW FOR ANY

PERSON, UNLESS THEY ARE ACTING

UNDER THE DIRECTION OF A LICENSED

PROFESSIONAL ENGINEER, TO ALTER

THIS DOCUMENT.

1478 STONE POINT DRIVE, SUITE 350

ROSEVILLE CA 95661

TEL

FAX

borgesarch.com

916 782 7200

916 773 3037

San Ramon, CA 9458312657 Alcosta Blvd., Suite 300

1524 RAINBOW TROUT STREETROSEVILLE, CA 95747

A 10/03/18100% ZD SUBMITTAL

B 10/30/18 100% ZD REV 1

1/4"=1'-0"

2'4' 4' 8'

Page 9: San Ramon, CA 94583 SITE NAME: EL CAMINO REAL CASCADE #: … El Camino Real - Plans.pdf · 2019-01-29 · EMERGENCY SIGNAGE EME-2 100% ZDs T-16503-79 APE MTD BURLINGAME, CA 9410 1234

TOP OF (E) BUILDING

±33'-0" A.G.L.

GROUND LEVEL

0'-0"

TOP OF (E) PENTHOUSE STEATH TOWER

±42'-0" A.G.L.

RAD CENTER OF (E) CLEARWIRE MICROWAVE DISHES

±40'-8" A.G.L.

RAD CENTER OF (P) SPRINT ANTENNAS

±39'-0" A.G.L.

(E) STEALTH SCREEN

ANTENNA ENCLOSURE

(E) BUILDING

(E) PENTHOUSE

(E) STEALTH SCREEN BOX

(P) SPRINT

BATTERY CABINET

(P) SPRINT

RADIO CABINET

(P) RAISED PLATFORM

(P) (2) SPRINT 4 PORT 800 RRH

MOUNTED ON (P) ANTENNA PIPE

(P) SPRINT 4 PORT 800 RRH &

1900 RRH MOUNTED ON (P)

ANTENNA PIPE

17

1/4" = 1'-0"

PROPOSED SOUTHWEST ELEVATION

Existing Southwest Elevation

(E) MICROWAVE

(P) (2) SPRINT TRIBAND ANTENNA

MOUNTED ON (P) ANTENNA PIPE

(P) (2) 1900 RRH MOUNTED

ON (P) ANTENNA PIPES

(P) (2) SPRINT 2.5 RRH MOUNTED

ON (P) ANTENNA PIPE

(P) SPRINT 2.5 RRH

MOUNTED ON (P) UNISTRUT

TO (E) WALL

TOP OF (P) EQUIPMENT CABINET

±39'-3" A.G.L.

ELEVATIONS

A-3.4

100% ZDs

T-16503-79

APE

MTD

BURLINGAME, CA 9410

1234 EL CAMINO REAL

SF52XC160

El Camino Real

10/30/18

Plot

Dat

e:10

/30/

2018

4:3

7:20

PM

F

ile N

ameT

:\20

16\T

-165

03_P

reci

sion

Site

Dev

elop

men

t LLC

\SF5

2XC

160-

79\S

F52X

C16

0\Sh

eets

\Bui

ldin

g A

\A-3

.4 E

LEV

ATIO

NS.

dw

g

Plot

ted

By:

Ant

hony

Erle

r

REV DESCRIPTIONDATE

SHEET TITLE

SHEET NUMBER

CHECKED BY:

DRAWN BY:

PROJECT NO:

IT IS A VIOLATION OF LAW FOR ANY

PERSON, UNLESS THEY ARE ACTING

UNDER THE DIRECTION OF A LICENSED

PROFESSIONAL ENGINEER, TO ALTER

THIS DOCUMENT.

1478 STONE POINT DRIVE, SUITE 350

ROSEVILLE CA 95661

TEL

FAX

borgesarch.com

916 782 7200

916 773 3037

San Ramon, CA 9458312657 Alcosta Blvd., Suite 300

1524 RAINBOW TROUT STREETROSEVILLE, CA 95747

A 10/03/18100% ZD SUBMITTAL

B 10/30/18 100% ZD REV 1

1/4"=1'-0"

02'4' 4' 8'0

Page 10: San Ramon, CA 94583 SITE NAME: EL CAMINO REAL CASCADE #: … El Camino Real - Plans.pdf · 2019-01-29 · EMERGENCY SIGNAGE EME-2 100% ZDs T-16503-79 APE MTD BURLINGAME, CA 9410 1234

13

NOT TO SCALE

1.9GHz RRU MECHANICAL SPECIFICATIONS

1'-1 3/4"

1'-1

1 3

/4

"

9"

OPTIC PORT

FGND

ANT 0 ANT 1 ANT 2 ANT 3

ANTENNA PORTS

POWER

PORT

RET

PORT

GROUND

DIMENSIONS

HEIGHT: 350mm(13.8")

WIDTH: 605mm (23.8")

DEPTH: 228mm (9")

WEIGHT

(w/ FILTER): 65lbs

4

1" = 1'-0"

4 PORT 800 RRUS

PLAN VIEW

FRONT VIEWREAR VIEW

7.68"

15

.1

0"

7.68"

15

.1

0"

15

.1

0"

12.59"

MAKE & MODEL: SAMSUNG REFD01F SERIES

DIMENSIONS

HEIGHT: 15.10"

WIDTH: 12.59"

DEPTH: 7.68

WEIGHT: 48.50 LB

MOUNTING BRACKET

PROVIDED W/ RRH

MOUNTING BRACKET

PROVIDED W/ RRH

5

1/2" = 1'-0"

ELTEK CABINET DETAIL

38

.0

"

BATTERY CABINETS

FIBER CABINETS

EQUIPMENT

CABINETS

ELTEK Ecab / Bcab / Icab CABINETS

EQUIPMENT 450lbs

FIBER 155lbs

BATTERY 200lbs

TOTAL WEIGHT : 805lbs

FRONT VIEW

73

.6

"

EQUIPMENT CABINET

MOUNTING PLATFORMS

BATTERY CABINETS

FIBER CABINETS

EQUIPMENT CABINETS

72

.3

"

71

.4

"

83

.9

"

PLAN VIEWPLAN VIEW

45

.3

"

59.5"

BATTERY CABINETS

FIBER CABINETS

EQUIPMENT CABINETS

45

.3

"

EQUIPMENT CABINET

END VIEW

38.0"

73

.6

"

72

.3

"

77

.5

"

77

.5

"

3

1/2" = 1'-0"

TRI-BAND ANTENNA DETAIL

48"

7.8

"

21.0"

SIDE VIEWFRONT VIEW

ANTENNA MAKE AND MODEL

MANUFACTURER: CCI

MODEL: TPA65R-KE4DA

DIMENSIONS, HxWxD.in(min): 48" x 21.0" x 7.8"(IN)

WEIGHT: 51.8 lbs

CONNECTOR: 12 x 4.3-10 FEMALE

PLAN VIEW

17

1" = 1'-0"

SAMSUNG 2.5 RRUS

NOTES

GENERAL CONTRACTOR TO

ENSURE THAT ALL RRH'S

RECEIVE ELECTRICAL POWER

WITHIN 24 HOURS OF BEING

REMOVED FROM THE

MANUFACTURER'S

PACKAGING. DO NOT OPEN

RRH PACKAGES IN THE RAIN.

SIDE

VIEW

FRONT

VIEW

PLAN

VIEW

LED INDICATORS

POWER

15.5"

22.98"

18.6"

18.6"

9.45"

RF

CALIBRATION

PORT

RET CONNECTOR

AMPHENOL

FIBER MPO

CONNECTOR

(8) RF OUTPUT

PORTS

100% ZDs

T-16503-79

APE

MTD

BURLINGAME, CA 9410

1234 EL CAMINO REAL

SF52XC160

El Camino Real

10/30/18

Plot

Dat

e:10

/30/

2018

4:3

7:27

PM

F

ile N

ameT

:\20

16\T

-165

03_P

reci

sion

Site

Dev

elop

men

t LLC

\SF5

2XC

160-

79\S

F52X

C16

0\Sh

eets

\Bui

ldin

g A

\A-4

Equ

ipm

ent D

etai

ls.d

wg

Pl

otte

d B

y:A

ntho

ny E

rler

REV DESCRIPTIONDATE

SHEET TITLE

SHEET NUMBER

CHECKED BY:

DRAWN BY:

PROJECT NO:

IT IS A VIOLATION OF LAW FOR ANY

PERSON, UNLESS THEY ARE ACTING

UNDER THE DIRECTION OF A LICENSED

PROFESSIONAL ENGINEER, TO ALTER

THIS DOCUMENT.

1478 STONE POINT DRIVE, SUITE 350

ROSEVILLE CA 95661

TEL

FAX

borgesarch.com

916 782 7200

916 773 3037

San Ramon, CA 9458312657 Alcosta Blvd., Suite 300

1524 RAINBOW TROUT STREETROSEVILLE, CA 95747

A 10/03/18100% ZD SUBMITTAL

B 10/30/18 100% ZD REV 1

EQUIPMENT

DETAILS

A-4