sand2008-4515c sand2010-3874c lead azide and petn ......acknowledge transient behavior at output or:...

28
Lead Azide and PETN Reactions at Sub-mm Geometries Sandia National Laboratories is a multi-program laboratory operated by Sandia Corporation, a wholly owned subsidiary of Lockheed Martin company, for the U.S. Department of Energy’s National Nuclear Security Administration under contract DE-AC04-94AL85000. Alexander S. Tappan, Peter C. Jung, Robert Knepper, Ryan R. Wixom, Melvin R, Baer, Michael Marquez, J. Patrick Ball, Jill C. Miller, and Eric J. Welle Workshop on “Synthesis of Advanced Energetic Materials-The Path Forward”, College Park, MD, April 3-6, 2011. Alexander S. Tappan, Sandia National Laboratories, PO Box 5800, MS1454, Albuquerque, NM 87185 (505) 844-5768, [email protected] SAND2008-4515C SAND2010-3874C

Upload: others

Post on 22-Jan-2021

2 views

Category:

Documents


0 download

TRANSCRIPT

  • Alex Tappan, 1Alex Tappan, 1

    Lead Azide and PETN Reactions at Sub-mm Geometries

    Sandia National Laboratories is a multi-program laboratory operated by Sandia Corporation, a wholly owned subsidiary of Lockheed Martin company, for the U.S. Department of Energy’s National Nuclear Security Administration under contract DE-AC04-94AL85000.

    Alexander S. Tappan, Peter C. Jung, Robert Knepper, Ryan R. Wixom, Melvin R, Baer, Michael Marquez, J. Patrick Ball, Jill C. Miller, and Eric J. Welle

    Workshop on “Synthesis of Advanced Energetic Materials-The Path Forward”,College Park, MD,

    April 3-6, 2011.

    Alexander S. Tappan, Sandia National Laboratories,PO Box 5800, MS1454, Albuquerque, NM 87185(505) 844-5768, [email protected]

    SAND2008-4515C SAND2010-3874C

    mailto:[email protected]

  • Alex Tappan, 2

    IntroductionExplosives Scaling

    • Desire to reduce the amount of sensitive explosives in energetic components– Safety– Undesirable materials (e.g., lead)

    • Stewart suggested:– Acknowledge transient behavior at output or:– Select material with suitable critical parameters

    (reaction zone, critical diameter)

    Stewart, D.S., "Towards the miniaturization of explosive technology," Shock Waves, vol. 11, pp. 467-473, May, 2002.

  • Alex Tappan, 3

    IntroductionDDT

    • Deflagration to Detonation Transition (DDT)– Secondary explosives – long length scales– Primary explosives – short length scales

    • DDT mechanisms – how does burning grow to a detonation?– Conductive → Convective → Shock wave• Or:– Compaction → Plug Formation → Shock wave

    • Understanding the process of DDT in small explosives is important for scaling

    Dickson, P.M., Parry, M.A., and Field, J.E., "Initiation and Propagation in Primary Explosives," Ninth Symposium (International) on Detonation, Portland, OR, August 28-September 1, 1989, pp. 1100-1109.

    Dickson, P.M. and Field, J.E., "Initiation and Propagation in Primary Explosives," Proceedings: Mathematical and Physical Sciences, vol. 441, pp. 359-375, 1993.

    Ermolaev, B.S., Sulimov, A.A., Okunev, V.A., and Khrapovskii, V.E., "Mechanism for Transition of Porous Explosive System Combustion into Detonation," Combustion, Explosion, & Shock Waves, vol. 24, pp. 65-68, 1988.

  • Alex Tappan, 4

    IntroductionLead Azide DDT in Glass Capillary

    • Early work• 400-µm inner

    diameter capillary• Based on this

    result, further experiments were conducted to examine the DDT process in sub-mm lead azidecharges

    Madden, S.P., Tappan, A.S., Jung, P.C., Marley, S.K., Welle, E.J., and Pahl, R.J., "Rapid Data Analysis Methodologies for Streak Camera Images: Measurement of Detonation Velocity and DDT Distance of Lead Azide at Sub-Millimeter Diameters," 13th International Detonation Symposium Norfolk, VA, July 23 – 28, 2006.

    Jung, P.C., "Initiation and Detonation in Lead Azide and Silver Azide at Sub-Millimeter Geometries," Mechanical Engineering, Master's Thesis Lubbock: Texas Tech University, December, 2006.

  • Alex Tappan, 5

    Lead Azide

    • Colloidal lead azidesynthesized by Pacific Scientific Energetic Materials Co., Chandler

    • 6-µm average particle size

    Lead Azide Coulter Light-Scattering Particle Size Analysis

    0123456

    0.1 1 10 100Diameter (microns - logarithmic scale)

    Volu

    me

    % PbN6PSEMC EL2J055A SEM of lead azide.

    Particle size analysis of lead azide.

  • Alex Tappan, 6

    Lead Azide Charge Examples

    • Dispersed with 1% dispersant• Not pictured: 10-µm diameter charge

    200-µm diameter charge

    50-µm diameter charge

    100-µm diameter charge

    mm

    mm

    mm

  • Alex Tappan, 7

    Experiment Setup

    Streak Camera

    Macro Lens

    Capillary

    Fused Silica Window

    400-µm fiber optic delivery from Nd:YAG

    laser

    Initiation at capillary / window interface

    Direction of propagation

    Optical Train

    Custom Drilled SMA Connector

    Capillary

    Optical Window

    SMA Connector & Laser Fiber optic

    Viewport Cutout

    Fixturing

    1” dia. ThorLabs Lens Tube

  • Alex Tappan, 8

    Lead Azide Reaction Comparisons

    • Detonation occurred in capillaries with longer filled columns

    • Apparent self-confinement effect

    0.0 0.5 1.0 1.5 2.0 2.5 3.0 3.5 4.0 4.5 5.0-0.5

    0.0

    0.5

    1.0

    1.5

    2.0

    x (m

    m)

    t (µs)

    0.0 0.5 1.0 1.5 2.0 2.5 3.0 3.5 4.0 4.5 5.0

    0.0

    0.5

    1.0

    1.5

    2.0

    x (m

    m)

    t (µs)

    0.0 0.5 1.0 1.5 2.0 2.5 3.0 3.5 4.0 4.5 5.0

    -0.5

    0.0

    0.5

    1.0

    1.5

    x (m

    m)

    t (µs)

    0.0 0.2 0.4 0.6 0.8 1.0 1.2 1.4 1.6 1.8 2.0

    0.0

    0.5

    1.0

    1.5

    2.0

    x (mm)

    t (µs)

  • Alex Tappan, 9

    Diameter Effect in Lead Azide• Six capillaries

    achieved steady detonation (50-, 100-, and 200-µm)

    • Difficult to separate diameter (known) effect from possible density (unknown) effect

    • For small sizes, diameter approached particle size and may have had an effect on the density

    • For these samples, the critical diameter is less than 50-µm

    2 4 6 8 10 12 14 16 18 20 22 242.62.72.82.93.03.13.23.33.43.5

    D (m

    m/µ

    s)

    1/Diameter (mm-1)

    Diameter (mm)0.200 0.100 0.050

  • Alex Tappan, 10

  • Alex Tappan, 11

    Introduction

    • Data for small-scale explosive behavior of high-density PETN do not exist• Difficult to prepare small-scale samples• Low-density PETN data exist (ca. 50% TMD)• High-density PETN data exist only for PBX with 20%

    binder• Critical diameter of 0.222 mm (polycarbonate confinement)

    Rate stick experiment.PETN Detonation failure experiment.Campbell, A.W. and Engelke, R., "The Diameter Effect in High-Density Heterogeneous Explosives," 6th Symposium (International) on Detonation, Coronado, CA, August 24–27, 1976. Gibbs, T.R. and Popolato, A., "LASL Explosive Property Data," pp. 289–290, University of California Press, Berkeley, Los Angeles, London, 1980.

  • Alex Tappan, 12

    Physical Vapor Deposition Can Be Used to Make Small-Scale PETN Samples

    • Physical vapor deposition is used to sublime/evaporate PETN from a hot source onto a cool substrate

    • Substrates are 0.5 10.0 30.0 mm fused silica• Shadow masks are used to pattern lines of different widths

    • 0.40, 0.60, 0.80, 1.00, 1.50, and 2.00 mm• Deposition times control thicknesses (0.13–0.53 µm)

    Photograph of bare substrate prior to deposition.

    Photograph of deposited PETN films.

  • Alex Tappan, 13

    PETN Surface Roughness Evolution

    Surface roughness increases according to a power law with increasing film thickness.

    Surface profile of a 117 µm

    PETN film.

    SEMs of different film thicknesses.

    117 µm

    37 µm

    488 µm

    6 µm

    10 µm

  • Alex Tappan, 14

    PETN Films Have High Density and Fine Grain Structure

    • 1.41−1.50 g cm−3(79−84% theoretical maximum density (TMD) of 1.778 g cm−3)

    • Density gradient through thickness –densest at substrate

    • Columnar grains of PETN elongated in the direction of film growth Scanning electron micrograph of fractured

    PETN film on fused silica. Inset shows top surface of deposited film.

    Knepper, R., Tappan, A.S., and Wixom, R.R., "Controlling the Microstructure of Vapor-Deposited Pentaerythritol Tetranitrate (PETN) Films," 14th International Detonation Symposium, Coeur d’Alene, ID, April 11–16, 2010.

  • Alex Tappan, 15

    Top cage assembly with deposited PETN lines

    Bottom cage assembly with four-point line wave generator

    Detonation Velocity Measurement Experiment

    • Detonation in deposited PETN lines is achieved by a four-point line wave generator

    • Up to two experiments are conducted at once

    • Cage assembly accommodates different PETN line thicknesses

    • PETN confined within fused silica and epoxy

    Photograph of experiment used to measure detonation

    velocity.

  • Alex Tappan, 16

    Optical Fiber Probe Is Used to Measure Detonation Velocity

    • Optical fiber probe consists of seven 100 µm core silica fibers terminated in a six-around-one connector

    • Optical fibers inserted through laser-machined holes in fused silica lid and bonded with epoxy

    • Polished or pre-cleaved at lid• Data acquisition with Si photodetector

    Photograph of optical fiber probe lid on

    deposited PETN. Optical fibers illuminated to

    show position.Photograph of optical fiber probe with inset showing six-around-one connector.

  • Alex Tappan, 17

    Framing Camera Used for Qualitative Detonation Information

    Framing camera images of detonation in deposited PETN lines. 1.67 million frames per second (1/600 ns), 20 ns exposure time.

  • Alex Tappan, 18

    Framing Camera Used for Qualitative Detonation Information

    Framing camera images of detonation in deposited PETN lines. 1.67 million frames per second (1/600 ns), 20 ns exposure time.

  • Alex Tappan, 19Campbell, A.W. and Engelke, R., "The Diameter Effect in High-Density Heterogeneous Explosives," 6th Symposium (International) on Detonation, Coronado, CA, August 24–27, 1976.

    Data Analysis Is Conducted Using the Standard Critical Diameter Form

    Rth t

    Critical diameter configuration.

    Critical thickness configuration.

    D(∞)

    Rc, thc

  • Alex Tappan, 20

    Critical Thickness Measured for PETN

    Critical thickness graph for PETN.

    0.80 mm wide PETND(∞) = 7.82 0.05 mm/μs tc = 0.131 0.003 mm

    0.40 mm wide PETND(∞) = 7.70 0.05 mm/μs tc = 0.206 0.001 mm

  • Alex Tappan, 21

    Conclusions

    • Physical vapor deposition used to produce high-density PETN samples with small geometries

    • Density and surface roughness change with film thickness• Critical thickness shows dependence on PETN film width

    • 0.206 mm (0.40 mm wide)• 0.131 mm (0.80 mm wide)

    • Critical thickness less than 0.13 mm for films at “infinite width”• Unsteady light intensity in thin, narrow films

    • Funding: Joint Department of Defense/Department of Energy Munitions Technology Development Program

    • Thanks to: Marc Basiliere, Rosa Montoya, Adrian Casias, David Saiz, Thomas Gutierrez , M. Barry Ritchey

  • Alex Tappan, 22

  • Alex Tappan, 23Alex Tappan, 23

    Streak Camera and Analysis

    Low Velocity

    High Velocity

    Transition Point

    Time Axis

    Posi

    tion

    Axi

    s

    y = 2.6662x - 1.8992R2 = 0.9995

    y = 0.9323x2 - 0.4345x + 0.1058R2 = 0.9883

    0.0

    0.2

    0.4

    0.6

    0.8

    1.0

    1.2

    1.4

    1.6

    1.8

    0.0 0.2 0.4 0.6 0.8 1.0 1.2 1.4 1.6

    Time (µs)

    Posi

    tion

    (mm

    )

    Steady StateAcceleratingLinear (Steady State)Poly. (Accelerating)

    Streak camera block diagram.

    Raw image. Edge detection. x-t plot.

  • Alex Tappan, 24

    Density Decreases with Increasing Film Thickness

    • Density of deposited PETN at substrate interface is very high

    • Self-shadowing as film grows results in voids

    Density of deposited PETN film versus film thickness.

    LowerDensity

    HigherDensity

    Substrate

    D

  • Alex Tappan, 25

    Surface Profiler Measurements

    • Stylus surface profiler used for measurement

    • Center 100 µm of scan defined as film thickness

    • Each line thickness reported as average of 13 scans across film

    • Film thicknesses varied from 0.13–0.53 µm

    Surface profiler data superimposed on

    cartoon of deposited PETN.

    Surface profiler single line scans of 0.40, 0.80, and 1.50 mm wide vapor-deposited PETN films.

  • Alex Tappan, 26

    Optical Fiber Probe Signal Has Fast Rise and Fall Times

    • Full-width-half-maximum = 13 and 11 ns for graph at right

    • 0.1 mm core / 7.5 mm/µs = 13 ns

    Optical signal from two of seven fibers used to measure detonation light. An expanded view of the left pulse is shown in the inset.Substrate

    D

    100 µm Core Optical Fiber

  • Alex Tappan, 27

    Optical Fiber Probe Velocity Correlates Well with Streak Camera

    • Optical fiber probe and streak camera velocities agree to within 1% on multiple experiments

    • Analysis of optical fiber probe data is less subjective• When both are available, optical fiber data are used

    Optical fiber data and streak camera data from the same experiment.

  • Alex Tappan, 28

    Evidence of Unsteady Detonation Near the Critical Thickness

    • Thinner PETN films produced fluctuations in streak camera light intensity• Not observed in thick films or thin films that were also wide• No effect on velocity stability

    Unsteady light intensity,0.14 0.001 mm thick, 0.80 mm wide, 7.429 0.004 mm/μs, Shot018.

    Steady light intensity, 0.132 0.004 mm thick, 1.00 mm wide, 7.691 0.002 mm/μs, Shot036.

    Slide Number 1Introduction�Explosives ScalingIntroduction�DDTIntroduction�Lead Azide DDT in Glass CapillaryLead AzideLead Azide Charge ExamplesExperiment SetupLead Azide Reaction ComparisonsDiameter Effect in Lead AzideSlide Number 10IntroductionPhysical Vapor Deposition Can Be �Used to Make Small-Scale PETN SamplesPETN Surface Roughness EvolutionPETN Films Have High Density and �Fine Grain StructureDetonation Velocity �Measurement ExperimentOptical Fiber Probe Is Used to �Measure Detonation VelocityFraming Camera Used for �Qualitative Detonation InformationFraming Camera Used for �Qualitative Detonation InformationData Analysis Is Conducted Using the �Standard Critical Diameter FormCritical Thickness Measured for PETNConclusionsSlide Number 22Streak Camera and AnalysisDensity Decreases with Increasing Film ThicknessSurface Profiler MeasurementsOptical Fiber Probe Signal Has �Fast Rise and Fall TimesOptical Fiber Probe Velocity �Correlates Well with Streak CameraEvidence of Unsteady Detonation �Near the Critical Thickness