sat-1xsat-1xs user manual
TRANSCRIPT
-
7/26/2019 SAT-1XSAT-1XS User Manual
1/107
Aitelong Technology Co.,Ltd.
Aitelong Technology Co.,Ltd.
-
7/26/2019 SAT-1XSAT-1XS User Manual
2/107
Users manual of 2M series Transmission Analyzer
Function Contrast Table of 2M series Transmission Analyzer
Items SAT-1AS SAT-1BS SAT-1CS
Loop delay
Automatic protective switching test APS
Equi-directional 64Kbit/s test
Graphs analysis
Frequency test of 2M line signal
Level test of 2M line signal
V.35 V.24/RS232 X.21/V.11 V36/RS449
RS422/RS485 EIA530/EIA530A
Normal Inverse
Attention Other basic functions of 2M series Transmission Analyzer are same for each other.
Note: The user can view ninth part(Application example) in advance
in order to master the operationas soon as
possible.
-
7/26/2019 SAT-1XSAT-1XS User Manual
3/107
Users manual of 2M series Transmission Analyzer
Page I
ontents
1General EEEEEEEEEEEEEEEEEEEEEEEEEEEEEEEEEEEEE 1
2 Panel EEEEEEEEEEEEEEEEEEEEEEEEEEEEEEEEEEEEE 4
2. 1 Fr ont panel EEEEEEEEEEEEEEEEEEEEEEEEEEEEEE 4
2.2 Back panel EEEEEEEEEEEEEEEEE EEEEEEEEEEEEEEEE 11
2. 3 Si de panel EEEEEEEEEEEEEEEEEEEEEEEEEEEEEE 12
2.4 Upsi de panel EEEEEEEEEEEEEEEEEEEEEEEEEEEEEEEE 12
3Mai n menu EEEEEEEEEEEEEEEEEEEEEEEEEEEEEEEEEE 14
3. 1 Menus sel ecti onEEEEEEEEEEEEEEEEE EEEEEEEEEEEEE 15
3. 2 keyboard shortcuts EEEEEEEEEE EEEEEEEEEE EEEEEEE 15
4Test sett i ngsEEEEEEEEEEEEEEEEEEEEEEEEEEEEEEEEEE 17
4. 1 Tx/Rx1/ DATA port sett i ngEEEEEEEEEEEEEEEEEEEEEEEEEE 17
4. 2 Other sett i ng EEEEEEEEEEEE EEEEEEEEEE EEEEEEEEE 29
4. 3 Pri nterEEEEEEEEEEEEEEEEE EEEEEEEEEEEEEEEEE 32
5Adva.Set EEEEEEEEEEEEEEEEEEE EEEEEEEEEEEEEEEEE 33
5. 1 Frame i nformati on sett i ngEEEEEEEEEEEEEEEEEEEEEEEEEEE 34
-
7/26/2019 SAT-1XSAT-1XS User Manual
4/107
Users manual of 2M series Transmission Analyzer
Page II
5. 2 Sa4- 8 I nfoEEEEEEEEEEEEEEEEEEEEEEEEEEEEEEEE 35
5. 3 ABCD sett i ngEEEEEEEEEEEEEEEEEEEEEEEEEEEEEEEE 36
6Test resul tsEEEEEEEEEEEEEEEEEEEEEEEEEEEEEEEEEEE 37
6. 1 Normal test resul t EEEEEEEEEEEEEEEEEEEEEEEEEEEEEE 37
6. 2 GraphsEEEEEEEEEEEEEEEEEEEEEEEEEEEEEEEEEEEE 47
6. 3 Audi o test resul tsEEEEEEEEEEEEEEEEEEEEEEEEEEEEEE 49
6. 4 Audi o moni tor test resul t EEEEEEEEEEEEEEEEEEEEEEEEEEE 51
6. 5 Del ay tests resul t EEEEEEEEEEEEEEEEEEEEEEEEEEEEEE 53
6. 6 APS tests resul t EEEEEEEEEEEEEEEEEEEEEEEEEEEEEEE 54
6. 7 Ti me-sl ot anal ysi s resul t EEEEEEEEEEEEEEEEEEEEEEEEEEE 55
7Docum-manage EEEEEEEEEEEEEEEEEEEEEEEEEEEEEEEEEE 59
7. 1 Vi ewSetsEEEEEEEEEEEEEEEEE EEEEEEEEEEEEEEEEEE 59
7. 2 Vi ewResul tsEEEEEEEEEEEEEEEEEEEEEEEEEEEEEEEE 60
8Devi ce SetupEEEEEEEEEEEEEEEEEEEEEEEEEEEEEEEEEEE 62
8. 1 Di spl ay sett i ngEEEEEEEEEEEEEEEEE EEEEEEEEEEEEEE 63
8. 2 Pri nt sett i ngEEEEEEEEEEEEEEEE EEEEEEEEEEEEEEE 64
8. 3 Ti me sett i ng RTCEEEEEEEEEEEEEEE EEEEEEEEEEEEEE 64
-
7/26/2019 SAT-1XSAT-1XS User Manual
5/107
Users manual of 2M series Transmission Analyzer
Page III
9Appl i cati on exampl eEEEEEEEEEEEEEEEEEEEEEEEEEEEEEEE 64
9. 1 2Mbi t/ s channel servi ce of f error testsEEEEEEEEEEEEEEEEEEE 64
9. 2 2Mbi t / s channel servi ce on error test sEEEEEEEEEEEEEEEEEEE 66
9. 3 Nx64kbi t/ s channel testsEEEEEEEEEEEEEEEEEEEEEEEEEEE 68
9. 4 Del ay testsEEEEEEEEEEEEEEEEEEEEEEEEEEEEEEEE 70
9.5 Audi o test EEEEEEEEEEEE EEEEEEEEEEEE EEEEEEEEE 72
9. 6 Auto-Protecti ve Swi tch Test EEEEEEEEEEEEEEEEEEEEEEEE 73
9. 7 Audi o moni torEEEEEEEEEEEEEEEEEEEEEEEEEEEEEEE 75
9.8 Ti me-sl ot anal ysi sEEEEEEEEEEEEEEEEEEEEEEEEEEEEE 76
9. 9 Data test EEEEEEEEEEEEEEEEEE EEEEEEEEEEEEEEE 77
9. 10 Normal 64kbi t/ sEEEEEEEEEEEEEEEEEEEEEEEEEEEEEEE 81
10. Technol ogy Speci f i cati onsEEEEEEEEEEEEEEEEEEEEEEEEEEE 84
11. I nst rument software expl anati onEEEEEEEEEEEEEEEEEEEEEEEE 93
Techni cal support & contact usEEEEEEEEEEEEEEEEEEEEEEEEEEE 102
-
7/26/2019 SAT-1XSAT-1XS User Manual
6/107
Users manual of 2M series Transmission Analyzer
Page 1
hina Xian
1. General
2M series transmission analyzer is applicable for engineering construction, acceptance,daily maintenance
testing of the transmission system.Its performance is credible & steady, complete function,small volume, display in
English,operation expediently and easily.
2M series transmission analyzer can undertake tests of 2Mbit/s digital channel, V.24, V.35, V.36, X.21,RS-449,RS-485, EIA-530, EIA-530A, equi-directional 64Kbit/s interface digital channels. It has already been applied to test
access network transmission network digital data network(DDN) etc..
The following are testing items for 2Mbit/s interface digital channel:
Interrupt operation testing
In-line Error Testing
Performance testing of bit error, coding error, frame error, CRC error, E bit error
Patterns slip testing
Clock slip testing
Testing of signal drop-out, AIS alarm, frame far end alarm, multi-frame far end alarm, out of frame alarm,
asynchronizing pattern alarm
Level & frequency test of line signal
Signal level & frequency test of voice channel
-
7/26/2019 SAT-1XSAT-1XS User Manual
7/107
Users manual of 2M series Transmission Analyzer
Page 2
hina Xian
Signaling status displayVoice channel content display,
Voice channel busy & idle display
Voice monitoring
Direct connection mode
Audio frequency testing
Loop delay testing
Automatic protective switching test (APS)
Time-slot content analysis
Frame content analysis
Error performance analysis of G.821 G.826 M.2100
The following are testing items for V.24, V.35, V.36, X.21, RS-449, RS-485, EIA-530, and EIA-530A interface
digital channels:
Interrupt operation error test
Bit error test
Pattern slip test
-
7/26/2019 SAT-1XSAT-1XS User Manual
8/107
Users manual of 2M series Transmission Analyzer
Page 3
hina Xian
Alarm testing of signal drop-outFrequency test of line signal
Loop delay testing
Automatic protective switching test (APS)
G.821 M.2100 interrupt operation error test
The following are testing items for equi-directional 64Kbit/s interface digital channels:
Interrupt operation error test
Bit error
Pattern slip test
Signal drop out, AIS alarm
Frequency test of line signal
Loop delay test
Automatic protective switching test
G.821, M.2100 error performance analysis
-
7/26/2019 SAT-1XSAT-1XS User Manual
9/107
Users manual of 2M series Transmission Analyzer
Page 4
hina Xian
2. Panel
2.1Front panel
Status & Alarm indicator light
LCD
Monitor loudhailer
Power supply switch
Operation key Function key
Cursor-moved key
2.1.1 Status & Alarm indicator light
As is seen from chart2.2, the light only indicates the status of Rx1 or DATA port.
The right lights indicate current instrument status,green lights indicate the status normally, on the contrary red
lights indicate abormally.The instrument inspect event,then the red lights show for 0.5 seconds.If the event appear
Chart2.1. Front Panel
-
7/26/2019 SAT-1XSAT-1XS User Manual
10/107
Users manual of 2M series Transmission Analyzer
Page 5
hina Xian
Chart2. 2 I ndi cator
again in 0.5 seconds,it keep showing.The red lights black out after the events disappear.
The yellow lights on the left signal indicate history alarm document.The lights show
after the instrument inspect the event.They show yet when the event disappear until use
to clear.
Indicator explanation:
POWER Power supply working status indicator.The green light indicates the
instrument is working by inside battery or external power supply mode normally.The
red light indicates the instrument is working by inside battery,and it is lack of electronic
capacity,we must charge instantly.The yellow light indicates the instrument is working
by external power supply and charging at the same time.
SIGNAL The signals status indicator of Rx1 or DATA port
FRAME Rx1 port signal frame synchronization status indicator
MFRAME Rx1 port multi-frame synchronization status indicator
CRC-4 Rx1 port signal structure indicator
PATTERN Rx1 or DATA port signal pattern synchronization indicator
AIS Rx1 or DATA port input signal AIS alarm indicator
-
7/26/2019 SAT-1XSAT-1XS User Manual
11/107
Users manual of 2M series Transmission Analyzer
Page 6
hina Xian
RA
Far port frame alarm of Rx1 port input signal MRA Far port multi-frame alarm Rx1 port input signal
CODE ERR Rx1 port code error
FAS ERR Rx1 port frame error indicator
CRC ERR Rx1 port CRC error indicator
EBIT ERR Rx1 port EBIT error indicator
PAT SLIP Rx1 or DATA port testing pattern slip code indicator
BIT ERR Rx1 or DATA port bit error indicator
-
7/26/2019 SAT-1XSAT-1XS User Manual
12/107
Users manual of 2M series Transmission Analyzer
Page 7
hina Xian
Chart2.3 LCD
2.1.2 LCD (Liquid Crystal Display)
LCD dispart into three part, as is seen from chart2.3:
Status display section
The status display section is locationed in the top of LCD,the right displays current date and time.The left small
icon indicate the instrument working status.Each of small icons meanings are as follows:
-
7/26/2019 SAT-1XSAT-1XS User Manual
13/107
Users manual of 2M series Transmission Analyzer
Page 8
hina Xian
The instrument is being supplied with inside battery, and displays the batterys capacity.
The instrument is being charged or worked by external power supply.
The instrument is non-testing.
The instrument is DateTo test status.
The instrument is testing.
The instrument is testing with non-document.
The instrument is documenting tests course, the glittering icon indicates the document memory has
overflowed.
The instrument is being injected by error code.
The instrument alarms when it inspects error or alarm.
The instrument is view setting or result document.
The instrument is printing.
The instrument is connecting with a computer.
-
7/26/2019 SAT-1XSAT-1XS User Manual
14/107
Users manual of 2M series Transmission Analyzer
Page 9
hina Xian
The instruments keyboard has been locked, except for and , other keys are all
malfunction.You can cancel the keyboard locking when you press again.
The instruments LCD is been locked.
Main display section
The main section is been used to display the instruments setting & testing result.
Function key and function expanding key.
The key defining section locations at the bottom of LCD.Each black frames content show the fuction key
roles. Indicate further function key defining. Show functions shortcut key, please refer to 3.2
shortcut.
2.1.3 Monitor loudhailer
It is used to monitor voice channel contents,the volume can be adjusted at Audio Monitor or Audio Test
-
7/26/2019 SAT-1XSAT-1XS User Manual
15/107
Users manual of 2M series Transmission Analyzer
Page 10
hina Xian
menu,refer to 6.6 Audio Test-result or 6.7 Monitor Test-Result.
2.1.4 Keys
The keys can be divided into four groups: power supply switch, operation keys, function keys and cursor moving
keys, as is seen from chart2.4.The detailed roles are as follows:
Power supply switch
Continually press for 0.8 seconds, turn on or turn off the instrument power supply.
Chart2.4 Keys
Operation keys
Alarm history display reset key.It is used to clear history alarm.
Error codes inject key.It is used to inject various error codes when transfer signals.
Set/Test switch keys.It is be used to switch between setting menu and testing result.
-
7/26/2019 SAT-1XSAT-1XS User Manual
16/107
Users manual of 2M series Transmission Analyzer
Page 11
hina Xian
Tests Run/Stop keys.It is be used to run or stop testing.Return key.It is used to return previous menu from current menu, at last return to main menus.
Enter key.It is used to confirm the selection of setting items.
Function keys
Function keys (F keys).Detailed function is defined by LCD displayed contents of keys
definition sections.
Expanding function keys.It is used to change F function definitions.
Cursor moving keys
It is used to up, down, left and right moving.
2.2 Back panel
Nameplate
Reset holes: reset when the instrument works abnormally.
Hand strip
Chart2.5 Back panel
-
7/26/2019 SAT-1XSAT-1XS User Manual
17/107
Users manual of 2M series Transmission Analyzer
Page 12
hina Xian
2.3 Side panel
External power supply input port .
PRINT/PC port , connect with printer or computer.
Data port , convert into various standard V series interface and equi-directional 64kbit/s interface by commutator
cabels.
Chart2.6 Right-side panel
2.4 Upside panel
Chart2.7 Upside panel
65321 4
-
7/26/2019 SAT-1XSAT-1XS User Manual
18/107
Users manual of 2M series Transmission Analyzer
Page 13
hina Xian
Clock balance input port(three cores SIEMENS)
Clock unbalance input port(BNC)
Signals balance input port(three cores SIEMENS)
Signals unbalance input port(BNC)
Signals balance output port(three cores SIEMENS)
Signals unbalance output port(BNC)
-
7/26/2019 SAT-1XSAT-1XS User Manual
19/107
Users manual of 2M series Transmission Analyzer
Page 14
hina Xian
3. Main menu
Main menu display as chart3.1, you can enter into main menu at the following case.
(1)Turn on the instrument.
(2) Press once or time after time at other menus.
Chart3.1 Main menu
-
7/26/2019 SAT-1XSAT-1XS User Manual
20/107
Users manual of 2M series Transmission Analyzer
Page 15 hina Xian
3.1 Menus selectionThere is the following menu (signed) to select at main menu.
Tests setting Move cursor to Tests setting,press enter into and set testing items & parameters.You can
also move cursor to Tests setting and press F keys to select Normal Test,Through Test,Delay Test,Audio
Test,APS test,defaults setting,ViewSets etc.straightly.
Test Results Move cursor to Test Results, press enter into and show testing result. You can also move
cursor to Test Results and press F keys to select current result, Time-slot analysis, and audio monitor etc
straightly.
Docum Manage Move cursor to Docum Manage, press enter into. You can also move cursor to Test
Results and press F keys to select Docum ManageViewSets or ViewResult interface straightly.
Device Setup Move cursor to Device Setup, press enter into. You can also move cursor to Device
Setup and press F keys to select submenu: Display, Printer, RTC (time setting) or Versionstraightly.
LinkToPC Move cursor to LinkToPC, press or turn off the function;press Turn on
it,LCD display at status section.
Soft update Move cursor to Soft update, press or come into it.Press exit,press
come into instrument update function.The functionstrictly prohibit using.
3.2 keyboard shortcuts
-
7/26/2019 SAT-1XSAT-1XS User Manual
21/107
Users manual of 2M series Transmission Analyzer
Page 16 hina Xian
You can make use of it to come into any interface straightly, Result_Print, Lock_LCD, key_lock etc.
Press ,the left & down corner will flip up shortcut menus when the expanded function keys of any interface
display .As is seen from chart3.2,press again,then the menus disappear.
Move cursor to the selected items, press or to select Result_Print, Lock_LCD, key_lock or come
into Test_set, ViewSets, Current Result, View-Result and Device-Setup interface.
Chart3.2 Shortcuts menu
-
7/26/2019 SAT-1XSAT-1XS User Manual
22/107
Users manual of 2M series Transmission Analyzer
Page 17 hina Xian
4. Test settings
The interfaces of tests setting is composed of multi-screen interfaces, it is used to set instrument test items &
parameters.
4.1Tx/Rx1/DATA port setting
As is seen from chart4.1, its interfaces is 2Mbit/s and equal-direction 64kbit/s mode (when equal-direction
64kbit/s, it is invalid), the left indicates transfering port sets, the right indicates receiving port sets.Each columns
meanings is showed by chart4.2.
As is seen from chart4.3 and 4.5, its interfaces are V.24, V.35, V.36, X.21, RS-449, RS-485,
EIA-530 and EIA-530A mode, the left indicates transfering port sets, the right indicates receiving port sets.Each
columns meanings is showed by chart4.4 and 4.6.
-
7/26/2019 SAT-1XSAT-1XS User Manual
23/107
Users manual of 2M series Transmission Analyzer
Page 18 hina Xian
Chart4.1 Tx/Rx1 port setting Chart4.2 Tx/Rx1 port setting
-
7/26/2019 SAT-1XSAT-1XS User Manual
24/107
Users manual of 2M series Transmission Analyzer
Page 19 hina Xian
Chart 4.3 DATA port sync setting Chart 4.4 DATA port sync setting explanation
-
7/26/2019 SAT-1XSAT-1XS User Manual
25/107
Users manual of 2M series Transmission Analyzer
Page 20 hina Xian
Chart 4.5 DATA port asyn setting Chart 4.6 DATA port asyn setting explanation
4.1.1 Select tests setting interfaces
Move cursor to interfaces explanationcolumn, you can select PageUp, PageDown or Adva.Set.The tests setting
interfaces is consisted of Tx/Rx1/DATA port setting, others setting and printer setting.Press or turn
over it.
4.1.2 Working mode
Move cursor to working mode column, there are the following items to select:
-
7/26/2019 SAT-1XSAT-1XS User Manual
26/107
Users manual of 2M series Transmission Analyzer
Page 21 hina Xian
Normal Test: it is used to test error code, slip code, channels content etc.
Through Test: Select it, you can also test error code, slip code, channels content etc.
Audio Test: Select audio testing mode and test time-slot access (frequency and level).
Delay Test: Select it and face to all of 2Mbit/s accesss.
APS Test: it is used to test the systems automatic protective switching time.
4.1.3 The relationship between Tx and Rx
Move the cursor toRxcolumn, there are the following items to select:
RxThe parameters of Tx and Rx is one another independent,you can set respectively(except for tests pattern).
Rx=Tx The parameters of Tx and Rx is same.When change Tx,Rx change automatically.
4.1.4 Port mode
Move the cursor toPort mode column, there are following items to select, the port mode of Tx and Rx hold
consistent automatically.
2Mbit/s testing 2Mbit/s digital channel Equi-direction 64k:testing equal direction 64k digital channel
V.35 testing data channel
V.24 testing data channel
-
7/26/2019 SAT-1XSAT-1XS User Manual
27/107
Users manual of 2M series Transmission Analyzer
Page 22 hina Xian
V.36 testing data channel
X.21 testing data channel
RS-449 testing data channel
RS-485 testing data channel
EIA-530 testing data channel
EIA-530A testing data channel
4.1.5 Signal mode
Move the cursor toTx Signal mode column, there are the following items to select:
Un-frame: select unframed signal mode.
PCM31 select 31 channels signal mode.
PCM31CRC select 31 channels signal mode and provided with CRC-4 verify function.
PCM30 select 30 channels signal mode,the sixteenth timeslot is used to transfer signaling.
PCM30CRCselect 30 channels signal mode,the sixteenth timeslot is used to transfer signaling and providedwith CRC-4 verify function.
Move the cursor to Rx Signal modecolumn, there are the following items to select besides the above:
Automation: the instrument search appropriate signal mode, as is seen from chart4.7.
-
7/26/2019 SAT-1XSAT-1XS User Manual
28/107
Users manual of 2M series Transmission Analyzer
Page 23 hina Xian
Chart4.7 Search signal mode automatically
4.1.6 Data portMove the cursor toData portcolumn, there are the following items to select:
UnBalance 75: select UnBalance 75port.
Balance 120: select balance 120port.
-
7/26/2019 SAT-1XSAT-1XS User Manual
29/107
Users manual of 2M series Transmission Analyzer
Page 24 hina Xian
4.1.7 Clock mode
Move the cursor to Clock modecolumn, there are the following items to select:
Oscill: Tx signal clock select Oscill.
RCLK: Tx clock select RCLK.
4.1.8 Test Pattern
Move the cursor to TxTest Pattern column, there are the following items to select:
2e6-1 select the test pattern of instrument transfering or receiving to be2e6-1(ITUT0.151).
2e9-1 select the test pattern of instrument transfering or receiving to be 2e9-1.
2e11-1 select the test pattern of instrument transfering or receiving to be 2e11-1.
2e15-1 select the test pattern of instrument transfering or receiving to be 2e15-1.
2e20-1 select the test pattern of instrument transfering or receiving to be 2e20-1.
2e23-1 select the test pattern of instrument transfering or receiving to be 2e23-1.
WORD select the test pattern of instrument transfering or receiving to be 8bit manual code.After selectedWORD, , , , respectively defined as ENTER,ENSCAPEL, SET 1, CLR 0.Move
cursor to one bit by or ,press to select this bit SET 1, press to select this bit CLR 0,
affirm current modification operation.Press cancel current operation.Test pattern resume the
-
7/26/2019 SAT-1XSAT-1XS User Manual
30/107
Users manual of 2M series Transmission Analyzer
Page 25 hina Xian
unmodified status automatically.
OnInTest:it is used to 2Mbit/s error OnInTest testing,here Bit ErrorPattern SlipPattern Loss is invalid(RX
end is valid).
4.1.9 Pattern polarity
Move the cursor toPattern polarity column, there are the following items to select:
Normal: pattern Normal, receive or transfer pattern ITUT0.151 defined.
Inverse: pattern Inverse: receive or transfer reverse direction pattern ITUT0.151 defined.
4.1.10 Signal code
Move the cursor to Signal code column, there are the following items to select:
HDB3 select HDB3,input or output signal is HDB3 code.
AMI select AMI,input or output signal is AMI code.
4.1.11 Time-slot selectMove the cursor toTime-slot select column, there are the following items to select:
All TS: press to select them, there are 30 time-slots as testing channels when
The signal mode is PCM30CRC or PCM30; there is 31 time-slot as testing channels when the signal mode is
-
7/26/2019 SAT-1XSAT-1XS User Manual
31/107
Users manual of 2M series Transmission Analyzer
Page 26 hina Xian
PCM31CRC or PCM31.
N64k press to select N64k, select any time-slot as testing channels.
After operating the time-slot selection column, come into time-slot setting interface, as is seen from chart4.8.
Chart4.8 TS Setting
Time-slot setting ways: move cursor to the selected time-slot mark, press to select it,it displays in
reverse white.Press to clear the time-slot.Time-slot mark displays normally.Press to select all of
-
7/26/2019 SAT-1XSAT-1XS User Manual
32/107
Users manual of 2M series Transmission Analyzer
Page 27 hina Xian
time-slot.Press clear all of time-slot.Toward the selected time-slot,testing pattern is injected.
Idle time-slot setting ways: move cursor to the idle time-slot bit modified, press to ALL 1s, press
to ALL 0s entirely, press to set the selected bit as 1, press to clear the selected bit as 0.
4.1.12 Signal port
Move the cursor to Signal port column, there are the following items to select:
Terminal: signal input port impedance is 75or 120.
UnTerm: signal input port impedance is high resistance.
Monitor: signal input port impedance is 75or 120, and there is 26dB plus for input signal.
4.1.13 Sync mode
Move the cursor to Sync mode column, there are the following items to select:
Sync: Synchronous testing mode.
Asyn:asynchronous testing mode.
4.1.14 Analog mode.Move the cursor toAnalog mode column, there are the following items to select:
Analog DTE: Analog DTE testing mode.
Analog DCE: Analog DCE testing mode.
l f i i i l
-
7/26/2019 SAT-1XSAT-1XS User Manual
33/107
Users manual of 2M series Transmission Analyzer
Page 28 hina Xian
4.1.15 Speed
Move the cursor toSpeed column, there are the following items to select:
Previous speed: speed decrease.
Next speed: speed increase.
4.1.16 Clock polarity
Move the cursor toClock polaritycolumn, there are the following items to select:
Normal: Clock polarity Normal.
Inverse: Clock polarity Inverse.
4.1.17 Data length & stop bit
Move the cursor toData length & stop bitcolumn, there are the following items to select:
Data length: 5 6 7 8
Stop bits: 1 2
4.1.18Parity bitMove the cursor toParity bit column, there are the following items to select:
Parity bit: odd, even, 0, 1, none
4.1.19 Control signal
U l f 2M i T i i A l
-
7/26/2019 SAT-1XSAT-1XS User Manual
34/107
Users manual of 2M series Transmission Analyzer
Page 29 hina Xian
Move the cursor to Control signal column, there are the following items to select:
Turn on: select control signal to put through.
Turn off: select control signal to disconnect.
4.2 Other setting
As is seen from chart4.9.
Chart4.9 Others setting4.2.1 Error inject
Move the cursor toError inject column, there are the following items to select:
None: without any error inject.
U l f 2M i T i i A l
-
7/26/2019 SAT-1XSAT-1XS User Manual
35/107
Users manual of 2M series Transmission Analyzer
Page 30 hina Xian
Bit ERR select bit error inject it can be selected single or rate mode,the range of rate is 110-1 110-7.
PAT Slip: select pattern slip inject, injection can be selected as single.
FAS ERR select frame error inject, injection can be selected as single,series 2, series 3, series 4(framed
structure is valid).
After you selected error inject,if the inject times is selected as single,series 2, series 3, series 4,then press
once, correspond to inject one,two,three,or four error,display 0.5 seconds at status sections. If the
injection is selected as rate,press once,error inject start,display at status sections,press
again,inject error stop, disappear.
4.2.2 Alarm inject
Move the cursor toAlarm inject column, there are the following items to select:
None: there is not any alarm injected.
SIG Loss: select interrupt to inject.
AIS select alarm signal AIS to inject.
FAS Loss select out of frame alarm injection.RA select frame far end alarm injection.
MRA select multi-frame far end alarm injection.
4.2.3 DateTo Test
Users manual of 2M series Transmission Analyzer
-
7/26/2019 SAT-1XSAT-1XS User Manual
36/107
User s manual of 2M series Transmission Analyzer
Page 31 hina Xian
Move the cursor toDateTo Testcolumn, there are the following items to select:
Disabled: disable DateTo Test function.
Enabled: enable DateTo Test function.Display at status section.
Modify: enable DateTo Test function, set DateTo Test time, display at status section.
SLEEP: when the instrument enters into SLEEP status, it will turn off.The instrument will turn on
automatically as the setted test running time arrive, and display at status section.
4.2.4 TestPeriod
Move the cursor to TestPeriodcolumn, there are the following items to select:
Disabled: disable TestPeriodfunction.
Enabled: enable TestPeriod function.
Modify: enable TestPeriod function, set TestPeriod.
When the function enable, the instrument will test at the setted time and stop testing automatically.
4.2.5 Auto-Repeat
Move the cursor toAuto-Repeat column, there are the following items to select:Disabled: disable Auto-Repeat function.
Enabled: enable Auto-Repeat function.
When the function enable, the instrument will test at the setted time and run new testing automatically.
Users manual of 2M series Transmission Analyzer
-
7/26/2019 SAT-1XSAT-1XS User Manual
37/107
User s manual of 2M series Transmission Analyzer
Page 32 hina Xian
4.3 Printer
As is seen from chart4.10, the icon show option is valid, the icon show option is invalid.
Chart4.10 Printer
4.3.1 BeepAlarmBeepAlarmhint at the status of Rx1 or DATA port; it is valid when setted.
Error event: the instrument will beep an alarm sound when inspecting any error.
Alarm event: the instrument will beep an alarm sound when inspecting any alarm.
Users manual of 2M series Transmission Analyzer
-
7/26/2019 SAT-1XSAT-1XS User Manual
38/107
User s manual of 2M series Transmission Analyzer
Page 33 hina Xian
4.3.2 Start-up Print
Start-up Printis valid for Rx1 port, only at run testing.
Event occur: the printer start to print testing result when inspecting error and alarm event.
Test over: the printer print testing result when testing is over.
PrintPeriods: Print testing result according to the setted timing interval (default: 5 minutes).
4.3.3 Printouts
Printouts is valid for Rx1 or DATA port, only when starting to test.
Test settings: the test settings are included in Printouts.
Error Result: the various results of error tests are included in printing content.
Alarm Result: the various results of alarm tests are included in printing content.
Line analysis: the various results of line analysis tests are included in printing content.
Error analysis: G.821 analysis, G.826 analysis, M.2100 service off receiving directions analysis, M.2100
service on receiving directions analysis is included in printing content.
5. Adva.Set
When the port mode of Tx/Rx1/DATA setting intetface is 2Mbit/s, and the transfering signal mode is frame
structure, you can make this setting.
Users manual of 2M series Transmission Analyzer
-
7/26/2019 SAT-1XSAT-1XS User Manual
39/107
User s manual of 2M series Transmission Analyzer
Page 34 hina Xian
Press Adva.Setfunction keys, enter into current setting at Test_Set interface.
5.1Frame information setting
As is seen from chart5.1, move the cursor to modified bit, press ALL 1s, press ALL 0s,
press to make the selected bit SET 1, press to make the selected bit CLR 0.
Chart5.1 Frame Info setting
The revisable bits and corresponding default value of frame information are as follows:
Users manual of 2M series Transmission Analyzer
-
7/26/2019 SAT-1XSAT-1XS User Manual
40/107
y
Page 35 hina Xian
FAS Si: default value: 1.
NFAS Si: default value: 1.
NFAS A: default value: 0.
MFAS Y: default value: 0.
Select different frame structure correspond with different frame information; there is MFAS when select
PCM30/PCM30CRC, but PCM31/PCM31CRC none.
Uncorrect setting will produce error or alarm, please set according to default value.
5.2 Sa4-8 Info
As is seen from chart5.2, move the cursor to modified bit, press ALL 1s, press ALL 0s, press
to make the selected bit SET 1, press to make the selected bit CLR 0.
Users manual of 2M series Transmission Analyzer
-
7/26/2019 SAT-1XSAT-1XS User Manual
41/107
y
Page 36 hina Xian
Chart5.2 Sa4-8 Info
5.3 ABCD setting
As is seen from chart5.2, move the cursor to modified bit, press ALL 1s, press ALL 0s, press
to make the selected bit SET 1, press to make the selected bit SET 0.
Users manual of 2M series Transmission Analyzer
-
7/26/2019 SAT-1XSAT-1XS User Manual
42/107
Page 37 hina Xian
There is ABCD signaling when select PCM30/PCM30CRC frame structure, but PCM31/PCM31CRC none.
Each group ABCD value cant be ALL 0s.
Chart5.3 ABCD Sets
6. Test results
6.1Normal test result
When the working mode of Tx/Rx1/DATA port setting intetface is Normal Test orThrough test, the testing result
Users manual of 2M series Transmission Analyzer
-
7/26/2019 SAT-1XSAT-1XS User Manual
43/107
Page 38 hina Xian
is the display mode of normal test result.
6.1.1Error testing result
The error result is display as chart6.1, its meanings is explained as follows:
Testing result explanation, tests time.
Runtime, Timer(left time).
Main setting parameters at current tests.
Testing result content.
Testing result content:
Bit ERR bit error count
Bit ERR bit error rate
Code ERR coded error count
Code ERR coded error rate
FAS ERR frame error count
FAS ERR frame error rate
CRC ERR CRC-4 error count
CRC ERR CRC-4 error rate
Ebit ERR E bit error count
Users manual of 2M series Transmission Analyzer
-
7/26/2019 SAT-1XSAT-1XS User Manual
44/107
Page 39 hina Xian
Ebit ERR E bit error rate
PAT Slip pattern slip count
Chart6.1 Error test result
When the port mode of Tx/Rx1/DATA port setting intetface are V.24, V.35, V.36, X.21, RS-449,RS-485,
EIA-530,EIA-530A,the testing result is displayed as chart6.1-1:
Users manual of 2M series Transmission Analyzer
-
7/26/2019 SAT-1XSAT-1XS User Manual
45/107
Page 40 hina Xian
Chart6.1-1 V Series error result
Testing result content:
Bit ERR bit error count
Bit ERR bit error rate
PAT Loss the seconds of pattern loss(second)
PAT Slip pattern slip count
Users manual of 2M series Transmission Analyzer
-
7/26/2019 SAT-1XSAT-1XS User Manual
46/107
Page 41 hina Xian
SIG Loss the seconds of signal loss(second)
Freq max the max frequency value(Hz)
Freq min the min frequency value(Hz)
Control signal
The above error has statistical value and current value.Press function expanded keys (current value is
instantaneous error, statistical value is accumulative count).
Attention: Select different frame structure or different tests mode will display different content.
6.1.2 Alarm testing result
Alarm testing result is displayed as chart6.2:
Testing result content:
SIG Loss alarm seconds of signal loss(second)
AIS AIS(alarm indication signal) alarm happened seconds(second)
FAS Loss out of frame alarm seconds(second)
PAT Loss desynchronizing pattern seconds(second)
Users manual of 2M series Transmission Analyzer
-
7/26/2019 SAT-1XSAT-1XS User Manual
47/107
Page 42 hina Xian
RA RA(removed alarm) seconds(second)
MRA MRA(mutli-frame removed alarm) seconds(second)
PWR Loss power loss seconds(second)
Attention: Select different frame structure or different tests mode will display different content.
Chart 6.2 Alarm Result
Users manual of 2M series Transmission Analyzer
-
7/26/2019 SAT-1XSAT-1XS User Manual
48/107
Page 43 hina Xian
6.1.3 Line analysis result
Line analysis result display as chart6.3:
Testing result content:
Clock +Slip current second clock positive slip count
Clock -Slip current second clock minus slip count
Clock +Cpp clock positive slip accumulative count
Clock -Cpp clock minus slip accumulative count
Rx Freq RCV(Hz) current value of line signal frequency
Rx Freq RCV(ppm) current relative value of line signal frequency
Rx Freq max(Hz) the max value of line signal frequency
Rx Freq max(ppm) the max relative value of line signal frequency
Rx Freq min(Hz) the min value of line signal frequency
Rx Freq min(ppm) the min value of line signal frequency
Users manual of 2M series Transmission Analyzer
-
7/26/2019 SAT-1XSAT-1XS User Manual
49/107
Page 44
hina Xian
Chart6.3 Line result
6.1.4 Error performance analysis result
G.821 analysis, G.826 analysis, M.2100 service off receiving directions analysis, M.2100 service on receiving
directions analysis are included in error performance analysis result,as is seen from chart6.4:
G.821 analysis content:
ES(s) error seconds
ES(s) error seconds ratio
Users manual of 2M series Transmission Analyzer
-
7/26/2019 SAT-1XSAT-1XS User Manual
50/107
Page 45
hina Xian
SES(s) serious error seconds
SES(s) serious error seconds ratio
EFS(s) non-error seconds
EFS(s) non-error seconds ratio
DM(m) bad minute
DM(m) bad minute ratio
AS(s) available seconds
AS(s) available seconds ratio
UAS(s) unavailable seconds
UAS(s) unavailable seconds ratio
G.826 analysis content:
ES(s) error seconds
ES(s) error seconds ratio
SES(s) serious error seconds
SES(s) serious error seconds ratio
AS(s) available seconds
AS(s) available seconds ratio
Users manual of 2M series Transmission Analyzer
-
7/26/2019 SAT-1XSAT-1XS User Manual
51/107
Page 46
hina Xian
UAS(s) unavailable seconds
UAS(s) unavailable seconds ratio
EB error block
EB error block ratio
BBE backdrop error block
BBE backdrop error block ratio
M.2100 service off receiving directions analysis:
ES(s) error seconds
ES(s) error seconds ratio
SES(s) serious error seconds
SES(s) serious error seconds ratio
M.2100 service on receiving directions analysis:
ES(s) error seconds
ES(s) error seconds ratio
SES(s) serious error seconds SES(s) serious error seconds ratio
Users manual of 2M series Transmission Analyzer
-
7/26/2019 SAT-1XSAT-1XS User Manual
52/107
Page 47
hina Xian
Chart6.4 G.821 Result
6.2Graphs
When the working mode of Tx/Rx1/DATA setting intetface is Normal test orThrough test,the testing result can
be displayed by Graphs.
Users manual of 2M series Transmission Analyzer
-
7/26/2019 SAT-1XSAT-1XS User Manual
53/107
Page 48
hina Xian
Press Graphs function keys enter into Graphs analysis at normal testing result interface.as is seen from
chart6.5:
Chart6.5 Graphs
When Graphs are displaying, Level-axis represents time,vertical-axis represents current selected events value,
vertical line of level-axis shows the current value of corresponding event, and accessorial information is main alarm
Graphs, SIG Loss, AIS, FAS Loss, PAT Loss alarm is included, and the wide-line shows alarm information.
Users manual of 2M series Transmission Analyzer
-
7/26/2019 SAT-1XSAT-1XS User Manual
54/107
Page 49
hina Xian
Error or alarm type: press or to select the type wanted analysis.
Resolution: the min displayed unit at level-axis of Graphs.
Press to increase Resolution unit.
Press to decrease Resolution rate unit.
: cursor
Press , the cursor move to left.
Press , the cursor move to right.
Press to display PageUp Graphs contents.
Press to display PageDown Graphs contents.Item informationtime: the time of the cursor location, or the starting time of the cursor locations time
segment.
Item informationresult: the error counts or alarm seconds of the cursor location.
6.3 Audio test results
When the working mode of Tx/Rx1/DATA port setting intetface is Audio Test, the testing result is the displayed
mode of Audio Test result, as is seen from chart6.6.
Users manual of 2M series Transmission Analyzer
-
7/26/2019 SAT-1XSAT-1XS User Manual
55/107
Page 50
hina Xian
Setting items:
transfering time-slot: setting voice-slot of audio tests, refer to 4.1.11 Timeslot selection.
Working mode: select Audio or Monitor, when select monitor, it will not transfer audio signals.
Transfering frequency:set the selected voice slot signal frequencys value: 800Hz 1000Hz.
Transfering level: set the selected voice slot signal levels value: 0dBm -10dBm.
Port selection: audio frequency testing or monitoring Rx1 port.
Receiving time-slot: set voice time-slot of audio tests, only one slot can be selected.
Volume control: adjust the volume of instruments loudhailer, monitor or turn off.
Testing result:
Rx frequency: display the frequency tests result of selected voice time-slot.Rx level: display the level tests result of selected voice time-slot.
Users manual of 2M series Transmission Analyzer
-
7/26/2019 SAT-1XSAT-1XS User Manual
56/107
Page 51
hina Xian
Chart6.6 Audio Test Result6.4 Audio monitor test result
When the working mode of Tx/Rx1/DATA port setting intetface is normal testing or through testing,and Rx
test patternis selected OnInTest ,move the cursor to Tests results at main menu,pressaudio monitorfunction key to
enter into it,refer to 3.1 menus selection,as is seen from chart6.7.The monitor tests dont influence other testing.
Setting items:
Port selection: audio testing or monitoring Rx1 port.
Receiving time-slot: set voice time-slot of audio tests, only one slot can be selected.
Users manual of 2M series Transmission Analyzer
-
7/26/2019 SAT-1XSAT-1XS User Manual
57/107
Page 52
hina Xian
Volume control: adjust the volume of instruments loudhailer, monitor or turn off.
Testing result:
Rx frequency: display the frequency tests result of selected voice time-slot.
Rx level: display the level tests result of selected voice time-slot.
Chart6.7 Monitor Results
6.5 Delay tests result
Users manual of 2M series Transmission Analyzer
-
7/26/2019 SAT-1XSAT-1XS User Manual
58/107
Page 53
hina Xian
When the working mode of Tx/Rx1/DATA port setting intetface is delay tests, the tests result is delay tests
displayed mode, as is seen from chart6.8.
Tests way:
Press once,test one times.The delay tests result display bad signal indicate that the error performance
is worse on current line and unaccommodate delay tests.If the delay tests time exceed 2.5 seconds,the result displays
time overflow.
Users manual of 2M series Transmission Analyzer
-
7/26/2019 SAT-1XSAT-1XS User Manual
59/107
Page 54
hina Xian
Chart6.8 Delay Test Result
6.6 APS tests result
When the working mode of Tx/Rx1/DATA port setting intetface is APS tests, the tests result is APS tests
displayed mode, as is seen from chart6.9.
Tests way:
Press to start APS testing,when the instrument inspected APS,test the APS time and display tests
result.If the APS time exceed 2.5 seconds,the result displays time overflow.Press to stop APS testing
again when started APS testing.
Users manual of 2M series Transmission Analyzer
-
7/26/2019 SAT-1XSAT-1XS User Manual
60/107
Page 55
hina Xian
Chart6.9 APS Test Result
6.7 Time-slot analysis result
When the working mode of Tx/Rx1/DATA port setting intetface is normal testing or through testing and Rx
signal mode is selected as framed structure,move cursor to tests result column,press time-slot analysis function
key to enter into current interface at main menu interface.Refer to 3.1 menus selection,time-slot analysis tests
dont influence other testing.
Time-slot analysis, frame information, synchronization information and ABCD information is included in
time-slot result, as is seen from chart6.10, 6.11, 6.12, 6.13.
Time-slot analysis explanation:TS time-slot mark
BIN:binary system indicates time-slot content.
HEX: hex indicates time-slot content.
Users manual of 2M series Transmission Analyzer
-
7/26/2019 SAT-1XSAT-1XS User Manual
61/107
Page 56
hina Xian
Chart6.10 TS Analysis
Users manual of 2M series Transmission Analyzer
-
7/26/2019 SAT-1XSAT-1XS User Manual
62/107
Page 57
hina Xian
Chart6.11 Frame-Info
Frame information explanation
FAS: c0011011,binary system indicates odd frame content.
NFAS: i1asssss, binary system indicates even frame content.
MFAS: binary system indicates multi-frame synchronization content.
Select different frame structure to correspond with different frame information; there is multi-frame
Users manual of 2M series Transmission Analyzer
-
7/26/2019 SAT-1XSAT-1XS User Manual
63/107
Page 58
hina Xian
synchronization frame when select PCM30/PCM30CRC, but PCM31/PCM31CRC none.
Attention:there is ABCD signaling analysis when select PCM30/PCM30CRC,but PCM31/PCM31CRC
none.
Chart6.12 Sync Info Chart6.13 ABCD Info
Users manual of 2M series Transmission Analyzer
-
7/26/2019 SAT-1XSAT-1XS User Manual
64/107
Page 59
hina Xian
7. Docum-manage
7.1 View Sets
The instrument will save current setting into memorizer,in order to read next times.You can also read the stored
setting as current setting,as is seen from chart7.1.The left column of LCD is the filename of setting document,the
medium column is the created time of setting document,the right column is the interface mode of setting document.
Chart7.1 ViewSets
Users manual of 2M series Transmission Analyzer
-
7/26/2019 SAT-1XSAT-1XS User Manual
65/107
Page 60
hina Xian
7.1.1 Defaults
Move the cursor to current column, press defaults, current setting will transfer to defaults setting.
7.1.1 Save
Move the cursor to current column, press to save, current setting is saved as document.
7.1.3 View
Move the cursor to the document files wanted to read,press view,view the retailed content of setting
document,the LCD status section will show icon synchronously. Here it will not change current setting content.
Move the cursor to the document files wanted to read, press recall, current setting will be replaced by
this setting document immediately.
7.1.4 RenameMove the cursor to the document files wanted to modify, press to rename, make use of 26 English
characters and 10 numbers to edit & modify filename.
Attention: The setting document content can not be modified.
7.1.5 Delete
Move the cursor to the document files wanted to delete, press to delete.
7.2 View Results
Users manual of 2M series Transmission Analyzer
-
7/26/2019 SAT-1XSAT-1XS User Manual
66/107
Page 61
hina Xian
The instrument will save tests result into memorizer, in order to view next times, as is seen from chart7.2. The
left column of LCD is the filename of tests result document, the medium column is the created time of tests result
document, the right column is the interface mode of tests result document.
Chart7.2 View Results
7.2.1 View tests result document
Move the cursor to the document note wanted to view, press look over, look over the retailed content of
tests result document, the LCD status section will show icon synchronously.Here it will not change current tests
result content.
Users manual of 2M series Transmission Analyzer
7 2 2 P i t t t lt
-
7/26/2019 SAT-1XSAT-1XS User Manual
67/107
Page 62
hina Xian
7.2.2 Print tests result
Move the cursor to the document note wanted to print, press to print, external micro-printer will print
record tests result content.
7.2.3 Delete tests result record
Move the cursor to the document note wanted to delete, press to delete.
7.2.4 Clear tests result record
Move the cursor to any record note, press clear all of notes.
Attention: The instrument will view tests result automatically, and number in sequence.Please delete
void tests result document,in order to ensure the max storage space,so that when testing next times,you can
note the more time tests process.
8. Device Setup
At main menu interface,move the cursor to Device Setupcolumn,press corresponding function keys and enter
into this interface ,refer to 3.1 menus selection,as is seen from chart8.1.
Users manual of 2M series Transmission Analyzer
-
7/26/2019 SAT-1XSAT-1XS User Manual
68/107
Page 63
hina Xian
Chart8.1 Device Setup
8.1 Display setting
Contrast: move the cursor to contrast column, make use of , , function keys and
adjust the instrument LCD display contrast.
Back-light:move the cursor to background-light column,make use of ,
function keys and adjust the instrument LCD background-light.
Users manual of 2M series Transmission Analyzer
Always On: back light is always on
-
7/26/2019 SAT-1XSAT-1XS User Manual
69/107
Page 64
hina Xian
Always On: back-light is always on.
Always off: back-light is always off.
Timed: back-light light at stated time, it is off when overtop stated time, press any keys and the background
light again (default value: 5 second).
8.2 Print settingPort mode:serial interface print, the instrument link serial printer.
Baud rate: the instrument and printers appropriate baud rate.
Verrify: the instrument and printers appropriate parity bit.
Print test page:validate the connection between the instrument and the computer.
8.3 Time setting RTCSet device inside clock.
9. Application example
9.1 2Mbit/s channel service off error tests2Mbit/s channel service off error tests is mainly used to research equipment,construction,check & accept
engineering and maintain normally.It can test error characteristic of the tested system correctly.The link mode is as
chart9.1,the receive port is Rx1.
Users manual of 2M series Transmission Analyzer
-
7/26/2019 SAT-1XSAT-1XS User Manual
70/107
Page 65
hina Xian
Chart9.1 Service off error tests
9.1.1 Test settings
1. Turn on power switch, selectTest Settings and enter into Test Settings interface.2. Various setting of test settings is as follows:
Work mode: normal test
Tx/Rx1 port setting as follows:
Receiving: Rx Tx
Port mode: 2Mbit/s
Signal mode: unframed
Signal port: terminal
Rx1Tx Multiplexing equipment
Digital Network
Multiplexing equipment
Users manual of 2M series Transmission Analyzer
Data port: unbalance (75) or balance (120)
-
7/26/2019 SAT-1XSAT-1XS User Manual
71/107
Page 66
hina Xian
Data port: unbalance (75) or balance (120)
Clock mode: oscill
Tests pattern: 2e15-1
Pattern polarity: Normal
Signal code: HDB3
DateTo test, TestPeriod will be setted according to needs.
9.1.2 Start to test
When DateTo test is disabled,press to run,press again to stop.When Test period is
enabled,press to run,the instrument will stop testing automatically according to setted test period.When
DateTo test is enabled,the instrument will run testing automatically at setted beginning time.
9.1.3 Test Results
Connect the instrument with the tested system,if the front-pannel has not alarm displayed(without red LED
light),you can find the testing error(Bit ErrorCode Error),alarm(Signal LossAISPattern LossPWR Loss),pattern
slip,line signal frequency, G.821 G.826 M.2100(service off)error analysis ,etc. result.
9.2 2Mbit/s channel service on error tests
2Mbit/s channel service on error tests need not stop the operation of the tested channel, you can find the testing
error(Frame Error,CRC Error,Code Error,Ebit Error),alarm(Signal Loss,AIS,Frame Loss,RA,MRA,PWR Loss),line
Users manual of 2M series Transmission Analyzer
signal frequency, error analysis(G.826,M.2100) ,etc. result. The link mode is as chart9.2, the Tx port will not be
-
7/26/2019 SAT-1XSAT-1XS User Manual
72/107
Page 67
hina Xian
g q y, y ( , ) , , p
used.Advise you to use Rx1 when testing one channel.
Chart9.2 service on error tests
9.2.1 Test settings
1. Turn on power switch, selectTest Settings and enter into Test Settings interface.
2. Various setting of test settings are as follows:
Work mode: normal test
Rx1 port setting is as follows:
Port mode: 2Mbit/s
Signal mode:select PCM30 PCM30CRC PCM31 PCM31CRC according to line signal results.
Signal port: UnTerm or monitor (usually select UnTerm on DDF rack, select monitor on the equipment
monitor-port)
Rx1
mul ti pl exi ng equi pment
DigNet
mul ti pl exi ng equi pment
Users manual of 2M series Transmission Analyzer
Data port: unbalance (75) or balance (120)
-
7/26/2019 SAT-1XSAT-1XS User Manual
73/107
Page 68
hina Xian
p ( ) ( )
Tests pattern: OnInTest
Signal code: HDB3
DateTo test, TestPeriod will be setted according to needs.
9.2.2 Start to test
When DateTo test is disabled,press to run,press again to stop.When Test period is
enabled,press to run,the instrument will stop testing automatically according to setted test period.When
DateTo test is enabled,the instrument will run testing automatically at setted beginning time.
9.2.3 Test Results
Connect the instrument with the tested system,if the front-pannel has not alarm displayed(without red LED
light),you can find the testing error(Code Error,Frame Error,CRC Error,Ebit Error),alarm(Signal Loss,AIS,Frame
Loss,RA,MRA,PWR Loss), line signal frequency, error analysis(G.826,M.2100 service on ),etc. result.
Attention: There is corresponding error and alarm when selecting different signal.
9.3 Nx64kbit/s channel tests
Nx64kbit/s channel tests is testing of some or many 64kbit/s channel at 2Mbit/s channel.It is mainly used to test
for switch-equipment,cross-connecting facility of research and project .The link mode is showed as chart9.3.
Users manual of 2M series Transmission Analyzer
1
2
3
1
2
3
-
7/26/2019 SAT-1XSAT-1XS User Manual
74/107
Page 69
hina Xian
Chart9.3 N 64kbit/schannel tests
9.3.1 Test settings
1. Turn on power switch, selectTest Settings and enter into Test Settings interface.
2. Various setting of test settings are as follows:
Work mode: normal test
Tx/Rx1 port setting is as follows:
Port mode: 2Mbit/s
Signal mode:select PCM30 PCM30CRC PCM31 PCM31CRC according to line signal results.
Signal port: Terminal
Data port: unbalance (75) or balance (120)Clock mode: oscill
Tests pattern: 2e15-1
Rx1Tx
Di gi tal cross-connect f aci l i ty
2Mbi t/ s
3
4
28
29
30
31
3
4
28
29
30
31
2Mbi t/ s
Users manual of 2M series Transmission Analyzer
Pattern polarity: Normal
-
7/26/2019 SAT-1XSAT-1XS User Manual
75/107
Page 70
hina Xian
Signal code: HDB3
Time-slot selection select according to actually case,the above examples Tx time-slot select second TS,
Rx time-slot select twenty-eighth TS.
DateTo test, TestPeriod will be setted according to needs.
9.3.2 Start to test
When DateTo test is disabled,press to run,press again to stop.When Test period is
enabled,press to run,the instrument will stop testing automatically according to setted test period.When
DateTo test is enabled,the instrument will run testing automatically at setted beginning time.
9.3.3 Test Results
Connect the instrument with the tested system,if the front-pannel has not alarm displayed(without red LED
light),you can find the testing error(Bit Error,Code Error,Frame Error,CRC Error,Ebit Error),alarm(Signal
Loss,AIS,Frame Loss,RA,MRA,PWR Loss), line signal frequency, error analysis(G.821,G.826,M.2100),etc. result.
Attention: There is corresponding error and alarm when selecting different signal.
9.4 Delay tests
Delay tests is testing of some or many 64kbit/s channel at all of 2Mbit/s channel.It is mainly used to test for
Users manual of 2M series Transmission Analyzer
transmission system, switch-equipment,cross-connecting facility of research and project .The link mode is showed as
-
7/26/2019 SAT-1XSAT-1XS User Manual
76/107
Page 71
hina Xi
an
chart9.1,9.3.This testing can only use Rx1 port.The instrument can also test for V.24,V.35,V.36,X.21,RS-449,
RS-485, EIA-530, EIA-530A, equal-direction 64k port delay, and it must work at synchronization mode, rate setting
must bigger than 64kbit/s (3264k best of all).
9.4.1 Test settings
Work mode: delay test
Tx/Rx1 port setting as follows:
Port mode: 2Mbit/s
Signal mode:select unframed when test all of 2Mbit/s ;select PCM30PCM30CRCPCM31PCM31CRC
according to line signal results.
Signal port: TerminalData port: unbalance (75) or balance (120)
Clock mode: oscill
Tests pattern: 2e15-1
Pattern polarity: Normal
Signal code: HDB3
Time-slot selection select according to the tested channel
9.4.2 Start to test
Users manual of 2M series Transmission Analyzer
Press to enter into delay test interface, as chart6.8.
P t th lt ill di l
-
7/26/2019 SAT-1XSAT-1XS User Manual
77/107
Page 72
hina Xi
an
Press to run, the result will display.
9.5 Audio test
Audio test is mainly used to test for telephone switch-equipment, PCM modem.The link mode is showed as
chart9.1, and 9.3.This testing can only use Rx1 port.
9.5.1 Test settings
Work mode: delay test
Tx/Rx1 port setting is as follows:
Port mode: 2Mbit/s
Signal mode:select PCM30 PCM30CRC PCM31 PCM31CRC according to line signal results.
Signal port: Terminal
Data port: unbalance (75) or balance (120)
Clock mode: oscill
Signal code: HDB3
9.5.2 Run testing
Press to enter into audio test interface, the result displays at menu, as chart6.6.
Users manual of 2M series Transmission Analyzer
You can set the selected time-slot of Tx end, audio test signal frequency & level (range) at audio tested result.At
-
7/26/2019 SAT-1XSAT-1XS User Manual
78/107
Page 73
hina Xi
an
Rx1 end, you can also select the test time-slot similarly.
The tested result can display the frequency & level (range) of testing time-slot audio signal.As test audio signal,
you can monitor by loudhailer.
9.6 Auto-Protective Switch Test
SDH network have APS function wholely.SDH can start up standy fiber-cabel automatically when workingfiber-cabel is cutted off in order to ensure communication.It needs time when the equipment switch fiber-cabel,APS
testing is test switched time.The link is showed as chart9.4. APS testing use Tx & Rx1 port.The instrument can also
test for V.24,V.35,V.36,X.21,RS-449,RS-485,EIA-530,EIA-530A,equal-direction 64k port APS,and it must work at
synchronization mode,rate setting must bigger than 64kbit/s(3264k best of all).
Chart 9.4 APS Test
Rx1Tx Mul ti pl exi ng Equi pment
Digtal Network
Mul ti pl exi ng Equi pment
Users manual of 2M series Transmission Analyzer
-
7/26/2019 SAT-1XSAT-1XS User Manual
79/107
Page 74
hina Xi
an
9.6.1 Device Setting
Work mode: APS test
Tx/Rx1 port setting as follows:
Receiving: Rx Tx
Port mode: 2Mbit/s
Signal mode: unframed
Signal port: terminal
Data port: unbalance (75) or balance (120)
Clock mode: oscill
Tests pattern: 2e15-1
Pattern polarity: Normal
Signal code: HDB3
9.6.2 Run testing
Press to enter into APS test interface, as chart6.9.
Users manual of 2M series Transmission Analyzer
Connect the instrument with the tested system, if the front-pannel has not alarm displayed (without red LED
-
7/26/2019 SAT-1XSAT-1XS User Manual
80/107
Page 75
hina Xi
an
light), you can press Run testing function keys and find the testing result.
9.7 Audio monitor
Audio monitor is used to monitor voice signal of any 64kbit/s channel at 2Mbit/s channel.
The link is showed as chart9.2.
9.7.1 Test settings
1. Turn on power switch, selectTest Settings and enter into Test Settings interface.
2. Various setting of test settings are as follows:
Work mode: normal test or through test
Rx1 port setting is as follows:
Port mode: 2Mbit/s
Signal mode:select PCM30 PCM30CRC PCM31 PCM31CRC according to line signal results.
Signal port: UnTerm or monitor (usually select UnTerm on DDF rack, select monitor on the equipment
monitor-port)
Data port: unbalance (75
) or balance (120
)
Tests pattern: OnInTest
Signal code: HDB3
Users manual of 2M series Transmission Analyzer
Time-slot selection select according to the monitored 64kb/s channel,but only one.
-
7/26/2019 SAT-1XSAT-1XS User Manual
81/107
Page 76
hina Xi
an
9.7.2 Run testing
Connect the instrument with the tested system,if the front-pannel has not alarm displayed(without red LED
light),select audio monitor of test result and enter into audio monitor interface,display test result,as chart6.7. Monitor
tests dont influence other testing.
The tested result can display the frequency & level (range) of testing time-slot audio signal.As test audio signal,
you can monitor by loudhailer.The volume can be adjusted.
9.8 Time-slot analysis
The instrument can monitor ABCD content and any 64kbit/s channel of 2Mbit/s signal,so that obtain each
channel busy & idle instance.
The link is showed as chart9.2 or chart 9.3.
9.8.1 Test settings
1. Turn on power switch, selectTest Settings and enter into Test Settings interface.
2. Various setting of test settings are as follows:
Work mode: normal test or through test
Rx1 port setting is as follows:
Users manual of 2M series Transmission Analyzer
Port mode: 2Mbit/s
-
7/26/2019 SAT-1XSAT-1XS User Manual
82/107
Page 77
hina Xi
an
Signal mode:select PCM30 PCM30CRC PCM31 PCM31CRC according to line signal results.
Signal port: UnTerm or monitor (usually select UnTerm on DDF rack, select monitor on the equipment
monitor-port)
Data port: unbalance (75) or balance (120)
Tests pattern: OnInTestSignal code: HDB3
9.8.2 Test analysis
Connect the instrument with the tested system,if the front-pannel has not alarm displayed(without red LED
light),select time-slot analysis sub-menu of test result,display test result.The time-slot analysis result have
time-slot,frame information,synchronization information and ABCD information,as chart6.10,6.11,6.12,6.13.Time
anlysis tests dont influence other testing.
9.9 Data test
The instrument can test error of V.24,V.35,V.36,X.21,RS-449,RS-485,EIA-530,EIA-530A,interface digital
channel.Select corresponding adapted cable to connect with tested equipment.Make use of data port of the
instrument side when data testing.
9.9.1 Test settings
Users manual of 2M series Transmission Analyzer
Work mode: normal test
DATA port setting as follows:
-
7/26/2019 SAT-1XSAT-1XS User Manual
83/107
Page 78
hina Xi
an
p g
Port mode: V.24 V.35 V.36 X.21 RS-449 RS-485 EIA-530 EIA-530A
Synchronization mode: select Synchronization or asynchronism according to test needs.
Analog mode: make sure the instrument to be analog DTE or DCE according to the tested port case.The
instrument is analog DCE when the tested equipment is DTE; the instrument is analog DTE when the tested
equipment is DCE.
Rate: select test signal rate.
Clock mode: usually select Oscill (synchronization mode)
Clock polarity: usually select equal direction (synchronization mode)
Data length, stop bits: select data length: 5, 6, 7, 8; stop bits: 1, 2(asynchronism mode)
Parity bit: select odd parity, even parity, 0, 1, none according to test need (asynchronism mode)
Tests pattern: 2e15-1
Pattern polarity: NormalControl signal: four control signals can be setted ON or OFF.
DateTo test, TestPeriod will be setted according to needs.
Users manual of 2M series Transmission Analyzer
-
7/26/2019 SAT-1XSAT-1XS User Manual
84/107
Page 79
hina Xi
an
9.9.2 Run testing
When DateTo test is disabled,press to run,press again to stop.When Test period is
enabled,press to run,the instrument will stop testing automatically according to setted test period.When
DateTo test is enabled,the instrument will run testing automatically at setted beginning time.
9.9.3 Test ResultsConnect the instrument with the tested system,if the front-pannel has not alarm displayed(without red LED
light),select current interface of test result and display test result.Please pay attention to synchronization clock setting
especially as DATACOM synchronization mode testing in order to ensure setting correctly.The test of data port can
make use of far end port loop-testing,near end/far end line loop-testing,far end port mutual-testing mode.The
connection of instrument testing and loop-testing points is showed from chart9.5,9.6,9.7.
Data Port Loop
short-link end
Terminal unit
Comm NetworkData Port
Terminal unit
Users manual of 2M series Transmission Analyzer
Chart9.5 Data Ports far-end loop-testing
-
7/26/2019 SAT-1XSAT-1XS User Manual
85/107
Page 80
hina Xi
an
Chart9.6 Data port near/far line loop-testing
Chart9.7 Data port mutual-testing
Terminal unit/Transmission unit
Comm Network
Far-end unit
loop loop
Data Port
Comm Network
Terminal unitTerminal unit
Data Port
Data Port
Users manual of 2M series Transmission Analyzer
9.10 Normal 64kbit/s
-
7/26/2019 SAT-1XSAT-1XS User Manual
86/107
Page 81
hina Xi
an
The instrument can test error of normal 64kbit/s interface digital channel.Select corresponding adapted cabel to
connect with tested equipment.Make use of data port of the instrument side when data testing.
9.10.1 Test settings
Work mode: normal test
DATA port setting as follows:Port mode: 64K CO
Data port: Normal interface
Rate: 64Kb/s
Clock mode:RxCLK RX=TX
Tests pattern: 2e11-1
Pattern polarity: Normal
DateTo test, TestPeriod will be setted according to needs.
9.10.2 Run testingWhen DateTo test is disabled,press to run,press again to stop.When Test period is
enabled,press to run,the instrument will stop testing automatically according to setted test period.When
Users manual of 2M series Transmission Analyzer
DateTo test is enabled,the instrument will run testing automatically at setted beginning time.
9 10 3 T t R lt
-
7/26/2019 SAT-1XSAT-1XS User Manual
87/107
Page 82
hina Xi
an
9.10.3 Test Results
Connect the instrument with the tested system,if the front-pannel has not alarm displayed(without red LED
light),select current interface of test result and display test result.
9.10.4 64Kb/s normal interface test ways
Far end port loop-testing: connect 64Kb/s normal interface receiving with transfering signal, the instrumentlinking is showed from chart9.8;
Near end/far end line loop-testing: loop near multiplexing equipments line (for example PCM equipment) or
transmission equipments line (for example SDH equipment), the instrument linking is showed from chart9.9;
Far end port mutual-testing: place one instrument at near end, the other at far end, test normal 64Kb/s
directly.the instrument linking is showed from chart9.10.
T
PCM unit
64Kb/s normal port loop
T
R Comm Network
T
R
T
RR
PCM unit
Users manual of 2M series Transmission Analyzer
Chart9.8 64Kb/s normal ports far-end loop testing
L L
-
7/26/2019 SAT-1XSAT-1XS User Manual
88/107
Page 83
hina Xi
an
Chart9.10 64Kb/s normal port far-end mutual-testing
T
R Comm Network
PCM unitPCM unit
T
R
T
R
T
R
T
R Comm Network
Far-end unitPCM/Transmission unit
T
R
Loop
Chart9.9 Near end/far-end line loop testing
Loop
Users manual of 2M series Transmission Analyzer
10.Technology Specifications
2M Technology Specifications:
-
7/26/2019 SAT-1XSAT-1XS User Manual
89/107
Page 84
hina Xi
an
2M Technology Specifications:(1) Signal Input Speed: 2048kbit/s 100ppm (G.703 standard50PPM
(2) Signal Coding: HDB3 AMI
(3) Input Vibration Tolerance: 10UI 20Hz 2.4Hz; 0.5UI 18 100Hz
(4) Input Equilibrium Character: attenuation accord with square root rule of frequency, the attenuation at 1024Khz
ranging within 0 6dB.
(5) Input Resistance
(5.1) Unbalanced Termination: 75W
Balanced Termination: 120W 50Hz 3100kHz reflection loss >18dB
(5.2) Unbalanced Bridging: >750W
Balanced Bridging: >1200W
(5.3) Unbalance Monitoring : 75W 26dB plus
Balance Monitoring: 120W 26dB plus
50Hz 3100kHz reflection loss >18dB(6)Signal Structure
(6.1)Unframed Structure
Users manual of 2M series Transmission Analyzer
(6.2)Framed Structure: PCM30, PCM31, PCM30CRC, PCM31CRC
Framed structure meets the G 704 standard
-
7/26/2019 SAT-1XSAT-1XS User Manual
90/107
Page 85
hina Xi
an
Framed structure meets the G.704 standard.(7)Testing Pattern: 2E6-1, 2E9-1, 2E11-1, 2E15-1, 2E20-1, 2E23-1, artificial code
(8)Output Interface Resistance
(8.1)Unbalanced 75W accord with G.703
(8.2)Balanced 120W accord with G.703
(9)External Clock Input
(9.1)Signal Format: HDB3 NRZ
(9.2)Balanced Termination Resistance: 120W
Unbalanced Termination Resistance: 75W
Balanced Bridging Resistance: >1200W
Unbalanced Bridging Resistance: >750W
(10)Error Injection: zero, single, proportioned injection 10E-1 10E-7
Equal-directional 64K Technology Index
(1) Signal Input Speed: 64kbit/s 100ppm (G.703 Requirement100PPM)
(2) Input Impedance: Balanced 120W accord with G.703
(3) Input Vibration Tolerance: accord with G.823
Users manual of 2M series Transmission Analyzer
(4) Output Interface Impedance: Balanced 120W accord with G.703
(5) Testing Pattern: 2E6-1 2E9-1 2E11-1 2E15-1 2E20-1 2E23-1 artificial code
-
7/26/2019 SAT-1XSAT-1XS User Manual
91/107
Page 86
hina Xi
an
(5) Testing Pattern: 2E6-1, 2E9-1, 2E11-1, 2E15-1, 2E20-1, 2E23-1, artificial codeData Interface Indexes
(1) Types of Data Interface: V.24, V.35, V.36, X.21, RS-449, RS-485,EIA-530,EIA-530A
(2) Generator
(2.1) Synchronous Mode
Clock Source: internal clock, receiving clock
Phase Relationship of Clock Data: equidirection, reverse direction
Speed: 1.2 2.4 4.8 9.6 14.4 19.2 38.4 48 56(kbps) N64kbps N=1 32
Error: 15ppm (PPM=parts per million)
(2.2) Asynchronous Mode
Speed: 50 75 110 150 200 300 600 1200 2400 3600 4800 7200 9600 14.4k 19.2k 38.4k
57.6k bps
Data Structure: word length: 5 6 7 8 bits stop bit: 1 2 bits
Parity Check: odd,even,1,0,zero.
(2.3) Error Injection: zero, single, proportioned injection 10-1 10-7
(3) Receiver
Users manual of 2M series Transmission Analyzer
(3.1) Synchronous Mode
Clock Source: Inner clock receiving clock
-
7/26/2019 SAT-1XSAT-1XS User Manual
92/107
Page 87
hina Xi
an
Clock Source: Inner clock, receiving clockPhase relationship between clock receiving and data receiving: equidirection, reverse direction.
Clock Speed: ultra speed is 2048kbps
(3.2) Asynchronous Mode: speed and data structure are the same as those of generator.
(4) Testing Patterns: 2E6-1, 2E9-1, 2E11-1, 2E15-1, 2E20-1, 2E23-1, artificial code.
Data Interface Character
(1) V.24 interface
Basic character:
The equivalent of RS-232/V.2825pin D linker interface
The max data speed: 128Kb/s
Driver:
Output voltage:
-15V -5V:binary system 1/OFF
+5V +15V:binary system 0/ON
Conversion speed:30V/us (max)
Short-circuit current: 100mA (max)
Users manual of 2M series Transmission Analyzer
Receiver:Input voltage:
3V max binary system 1/OFF
-
7/26/2019 SAT-1XSAT-1XS User Manual
93/107
Page 88
hina Xi
an
3V max binary system 1/OFF
0.8V min binary system 0/ON
(2) V.35 interface
Basic character:
Data and clock signal is balance circuit,electric character: V.35.
Balance circuit character:
A B binary system 1/OFF
A B binary system 0/ON
Control signal is unbalance circuit, electric character accord with V.28.
V.35 Drive:
End to end voltage: 0.44V 0.66V
Output resistance: 100
V.35 receives:
Input resistance: 100
V.28 Drive:
Output voltage:
Users manual of 2M series Transmission Analyzer
-15V -5V:binary system 1/OFF
+5V +15V:binary system 0/ON
Conversion speed: 30V/us (max)
-
7/26/2019 SAT-1XSAT-1XS User Manual
94/107
Page 89
hina Xi
an
Conversion speed: 30V/us (max)
Short-circuit current: 100mA (max)
V.28 Receive:Input voltage:
3V max binary system 1/OFF
0.8V min binary system 0/ON
3 V.36 interface
Basic charater:
Data and clock circuit accord with V.11 electric interface character.Control circuit accord with V.10 electric interface character.
37pin D type linker
V.11 drive
Open circuit voltage: max 5V
Min voltage of 100load: 2VShort circuit current: 150mA
V.11 receive
Difference input gate-limit voltage: 0.3V
Users manual of 2M series Transmission Analyzer
Input resistance: 100
V.10 drive
open circuit voltage 4V 6V
-
7/26/2019 SAT-1XSAT-1XS User Manual
95/107
Page 90
hina Xi
an
open circuit voltage 4V 6V
output voltage of 450load:3.6 5.4V
short circuit current 150mA
V.10 receive
Input current -3.25mA +3.25mA
Input resistance 4K
Difference input gate-limit voltage 0.3V
4 X.21 interface
Basic characterData and clock circuit accord with V.11 electric interface character.
Input clock and data interface has 120terminal resistance.
5 RS-449 interface
Basic characterData and clock circuit accord with V.11, V.10 electric interface character.
Input clock and data interface has 120terminal resistance.
Users manual of 2M series Transmission Analyzer
6 RS-485 interface
Basic character
-
7/26/2019 SAT-1XSAT-1XS User Manual
96/107
Page 91
hina Xi
an
Basic character
Data, clock, control signal accord with V.11, V.10 electric interface character.
Input clock and data interface has not terminal resistance.
7 EIA-530
Basic character
Data, clock, control signal accord with V.11, V.10 electric interface character.
Input clock and data interface has 120terminal resistance.
8 EIA-530A
Basic character
Data, clock, control signal accord with V.11, V.10 electric interface character.
Input clock and data interface has 120terminal resistance.
Other Parameters:
Power Supply:
Users manual of 2M series Transmission Analyzer
1 Special Power Supply Adapter for the Instrument
INPUT: AC220V 50HzOUTPUT DC 9V 1A
-
7/26/2019 SAT-1XSAT-1XS User Manual
97/107
Page 92
hina Xi
an
OUTPUT: DC 9V 1A
(2) Instrument interior rechargeable Battery
4000mAh 6V Nickel-Hydrogen rechargeable Battery
Working Time: eight hours
Charging: eight hours on working-off condition; twelve hours on working condition
Printer: Chinese-Character Micro-Printer withP40-TS(CH) standard Level Interface
Dimension and Weight
LengthWidthHeight: 20016042mm
Weight: 0.95Kg
Environment Parameters:
Operation Temperature: 0 40
Storage Temperature : -30 +70
Humidity: 5% 90% non-coagulate
Users manual of 2M series Transmission Analyzer
11. Software Specifications
11.1 Software installation11 1 1S ft i t
-
7/26/2019 SAT-1XSAT-1XS User Manual
98/107
Page 93
hina Xi
an
11.1.1Software environment
It is applicable to Windows98/Me/2000/XP, need to install Microsoft Excel beforehand.
11.1.2 Software install
Run SAT-1XS.exe to satart installation.
11.2 Data analysis software
Please open its linktoPC function, make PRINT/PC interface linking to RS232.
Dblclick SAT-1XScursor, open the software.The function has data operation, port setup, data analysis etc.
Users manual of 2M series Transmission Analyzer
11.2.1 DATA operation
Data reading, opening file, saving file, export file to Excel format are included in data operation.(1)Instrument data reading
-
7/26/2019 SAT-1XSAT-1XS User Manual
99/107
Page 94
hina Xi
an
(1)Instrument data reading
Press to open this function, after reading finished, will flip dialog box.
(2)Opening files
Click the menus opening files, open the saved document.
(3) Save files
Click , save the received data.the files postfix is .rbs.
(4) Export data to Excel
Users manual of 2M series Transmission Analyzer
Click to export.If you are viewing test result, the exported file is test result; if you are looking over
course report the exported file is course report
-
7/26/2019 SAT-1XSAT-1XS User Manual
100/107
Page 95
hina Xi
an
course-report, the exported file is course-report.
11.2.2 Port setting
Click to open this function, set the port number and baudrate.as is seen from chart11.1.
Chart11.1 Port setting
11.2.3 DATA Analysis
A Result analysis
Users manual of 2M series Transmission Analyzer
Click to open this function.You can look over error analysis, alarm analysis, line analysis, G.821 error
analysis, G.826 error analysis, M.2100 analysis; press to export file.As is seen from chart11.2, 11.3.
-
7/26/2019 SAT-1XSAT-1XS User Manual
101/107
Page 96
hina Xi
an
Chart 11.2 Result analysis Chart 11.3 Result analysis Excel format
B Course analysis
Click to open this function.You can look over various testing error, alarm,
Users manual of 2M series Transmission Analyzer
date, time, and amount;
Press to export file.As is seen from chart11.6, 11.7.
-
7/26/2019 SAT-1XSAT-1XS User Manual
102/107
Page 97
hina Xi
an
Chart 11.4 Course analysis
Users manual of 2M series Transmission Analyzer
-
7/26/2019 SAT-1XSAT-1XS User Manual
103/107
Page 98
hina Xi
an
Chart 11.5 Course analysis Excel format
C Graphs analysis
Click to open this function.
You can represent testing error,alarm amount by time segment resolution 1s 10s one minute ten minute
one hour on total time-axis.As is seen from chart11.8.
Users manual of 2M series Transmission Analyzer
-
7/26/2019 SAT-1XSAT-1XS User Manual
104/107
Page 99
hina Xi
an
Chart 11.6 Graphs
11.3 Software update module
The operation steps are as follows:
Users manual of 2M series Transmission Analyzer
(1)Turn on;
(2)Link to PC serial port.
(3)Select the instruments software update, press F1 to enter into the interface; press F2 to update, as is seen
-
7/26/2019 SAT-1XSAT-1XS User Manual
105/107
Page 100
hina Xi
an
from chart11.9.
(4) PC Update steps: chart 11.10.
1) Run Flash Magic.exe;
2) Operation steps
First:slect COM1 or COM2 or COM3 etc.
Select chip: 89C51RD2Hxx;
Users manual of 2M series Transmission Analyzer
Second: select Erase all Flash+Security
Third: select program code file, for example
SAT1CS.PRG;
-
7/26/2019 SAT-1XSAT-1XS User Manual
106/107
Page 101
hina Xi
an
Fourth: select Set Security bit 1/2/3
Fifth: click START to update.
Attention: please dont pause update process, ensure the
power supply normally.
3) Finished update: close PC Flash Magic, press POWER
reset.
Users manual of 2M series Transmission Analyzer
Technical Support & Contact US
-
7/26/2019 SAT-1XSAT-1XS User Manual
107/107
Page 102
hina Xi
an