save time fit the new universal-r - thermofrost...

3
the Universal-R v4.0 replaces over 150 models of refrigeration (and heating) controls Direct connection for either 12Vac/dc or 230Vac power supply Easy to programme in 3 Rapid Set-Up steps (see below) 6 facia buttons for direct access to main functions including On/Off Illuminated icons for showing status v4.0 can now control twin evaporator defrost v4.0 with built in compressor/condenser protection onboard v4.0 includes dead band control (with or without defrost) NEW SIMPLE 3 STEP RAPID SET-UP having connected up the probes and wiring: Press the ‘DOWN’ key for 3 seconds to automatically detect and set the probe type (PTC or NTC) Press the ‘AUX/tC’ key for 3 seconds to select the type of control you wish the Universal R to be Adjust the Set Point New version 4.0 with added features: Dual 12V/230V power supply 6 buttons for direct actions Twin evaporator defrost control Compressor protection Suitable for heating applications 1 2 3 The new Universal-R v4.0 Dual Voltage is designed to make life easier! Ernest Avenue, London SE27 0DA Tel: 020 8655 7600 Fax: 020 8761 8081 Email [email protected] www.thermofrostcryo.co.uk 530 Stretford Road Manchester M16 9AF Tel: 0161 872 2000 Fax: 0161 872 9929 Rea Street South Birmingham B5 6LB Tel: 0121 666 4700 Fax: 0121 622 7268 REFRIGERATION & AIR CONDITIONING Version 4.0 suitable for dual voltage supply: 12V or 230V in one controller! Fit the New Universal-R Save Time No more hunting around for a replacement controller

Upload: lamdien

Post on 03-Nov-2018

225 views

Category:

Documents


0 download

TRANSCRIPT

Page 1: Save Time Fit the New Universal-R - Thermofrost Cryothermofrostcryo.co.uk/downloads/refrigeration/controls/Universal_R... · the Universal-R v4.0 replaces over 150 modelsof refrigeration

the Universal-R v4.0 replaces over 150 models of refrigeration (and heating) controls

• Direct connection for either 12Vac/dc or 230Vac power supply• Easy to programme in 3 Rapid Set-Up steps (see below)• 6 facia buttons for direct access to main functions including On/Off• Illuminated icons for showing status• v4.0 can now control twin evaporator defrost• v4.0 with built in compressor/condenser protection onboard• v4.0 includes dead band control (with or without defrost)

NEW SIMPLE 3 STEP RAPID SET-UP having connected up the probes and wiring:Press the ‘DOWN’ key for 3 seconds to automatically detect and set the probe type (PTC or NTC)

Press the ‘AUX/tC’ key for 3 seconds to select the type of control you wish the Universal R to be

Adjust the Set Point

New version 4.0 with added features:

• Dual 12V/230V power supply• 6 buttons for direct actions • Twin evaporator defrost control• Compressor protection • Suitable for heating applications

1

2

3

The new Universal-R v4.0 Dual Voltage is designed to make life easier!

Ernest Avenue, London SE27 0DATel: 020 8655 7600Fax: 020 8761 8081Email [email protected]

530 Stretford Road

Manchester M16 9AF

Tel: 0161 872 2000

Fax: 0161 872 9929

Rea Street SouthBirmingham B5 6LBTel: 0121 666 4700Fax: 0121 622 7268

REFRIGERATION & AIR CONDITIONING

Version 4.0 suitable for dual voltage supply: 12V or 230V in one controller!

Fit the New Universal- RSave Time

No more hunting around for a replacement controller

Universal-R Mods Nov. 2010_Universal-R Nov.2010 1/12/10 8:28 AM Page 1

Page 2: Save Time Fit the New Universal-R - Thermofrost Cryothermofrostcryo.co.uk/downloads/refrigeration/controls/Universal_R... · the Universal-R v4.0 replaces over 150 modelsof refrigeration

The New Universal -R v4.0 Dual voltage controllerDesigned to replace the majority of refrigeration industry standard 32x74mm format controllers in their most typicalapplications, the Universal-R offers a convenient and versatile solution, fitting the same size cut out as the controllers it replaces and is suitable for both a 12v or a 230v supply.

ApplicationsThe Universal-R has 3 operational relays and one configurable relay. It can work with 1, 2 or 3 probes and can be programmed to operateas any of the following types of controller simply by setting the required application in the “smart” parameter tC

Model replacementThe Universal-R replaces over 150 other controllers in their mostcommon applications, including:LAE – replaces over 30 models from the MTR, SDU, MCDU,CDC, LDU, CDC, MP, LD and A rangesCarel – replaces over 20 models from the IR, CR and PJ rangesEliwell – replaces over 25 models from the EWTC, EWPC,EWPX, IC and ID rangesSAE – replaces RT31, RC31, RC31-1000, RC31-0100, RC32-000, RC33 and DC31 modelsIntek – replaces RK31, RK32, RK33, TK31 and DK31 modelsEvery/Evco – replaces 39 models from the EC3, FK and EVKrangesDixell – replaces 20 models from the XR and XR-CX rangesTeddington – replaces the EK-R31, EK-R32 and EK-R33Danfoss – replaces the EKC204 and EKC101Penn – replaces the MR1PM12R-1C, MR1PM230R-1C,MR2PM12R-1C, MR3PM12R-2C and MR4PM12R-2CBeta – replaces over 10 models from the RD, RT, RC, BL andWH series

For a complete list of models that the Universal-R can replaceplease see the Universal-R Replacement Guide, section 7 of ourCommercial price list, or the downloads section of our website.

Probe compatibility - with ‘Automatic Probe TypeRecognition’Not only is the Universal-R compatible with NTC or PTC probescommonly used by most other manufacturers, it will automatically detect which type (NTC or PTC) it has been connected to. And should you wish to replace the probes, 2 fullyencapsulated NTC probes (range -40°c to +105°c ) are includedin the box.

SpecificationsDual 12Vac/dc or 230Vac supply +/-10% 50/60Hz. Front Fasciawater protected to IP65. Control range maximum -50°c to +150°cdependant on probe(s) being used. Display resolution to 0.1c;Accuracy better than 1% FS. Anti-tamper keypad protection.Compressor short cycle protection. Energy saving set point. CEapproval. BS self extinguishing housing. Ambient conditions 0°cto +50°c, humidity 20 to 85%RH. Relay ratings 8(3)A/230V except fan 7(2)A/230V. Screw terminals for 2.5mm 2 max cables.Size (mm): 32H x 74W x 70D, Cut out(mm): 29H x 71W.

IncludesAudible/visual high & low temperature alarm plus a volt free relaywhich can be configured for alarms/auxiliary / light or dead bandcontrol. The digital inputs can be configured for external alarms- door switch - defrost - energy saving - remote on/off etc.

Ordering

• Universal-R complete with 2 NTC probes type NG6, range - 40°c to +105°c

• Optional 3rd NTC probe for twin evaporator defrost, type NG6, range -40°c to +105°c

• Optional 3rd NTC pipe probe for condenser / compressor protection, type NT6-67, range -40°c to +110°c

• Optional low temperature PTC probe(s) type S6.S, range -55°c to +110°c

• Optional high temperature PTC probe (for heating) type S6.SH, range to maximum +150°c

Parameter Type of Control No. of tC probes1 On / Off thermostat – Cooling 12 Thermostat with Off cycle defrost (timed) 13 Thermostat with Electric / Hot Gas defrost, time initiated / time terminated 14 Thermostat with Electric / Hot Gas defrost, time initiated / temperature terminated 25 Thermostat with Electric / Hot Gas defrost, time initiated / temperature terminated + evap. fan delay 26 Thermostat for Twin evaporator defrost applications (similar to setting 5 but with two evaporators) 37 On / Off thermostat – Heating 1

Wiring Diagram

Universal-R Mods 2011_Universal-R Nov.2010 16/02/11 10:15 AM Page 2

Page 3: Save Time Fit the New Universal-R - Thermofrost Cryothermofrostcryo.co.uk/downloads/refrigeration/controls/Universal_R... · the Universal-R v4.0 replaces over 150 modelsof refrigeration

APRIL 2011

COMPARISONCHARTS

T H E S P E C I A L I S T S

DIXELL UNIVERSAL-R REPLACEMENT GUIDE. For guide purposes only.

The Universal-R can replace all of the following controllers, providing all of their key functions. Some minor functions may not be offered.Note that the table below is not a comparison between the manufacturers listed.

LAE SAE INTEK AKO EVERY/EVCO DIXELL ELIWELL CAREL BETA TEDDINGTON DANFOSS MTR11 / T1RDS DC31 DK31 AKO-14112 / 8 EC3-120 XR110C EWPC901 IR32S RD31 EK-R31 EKC201-084B7005 MTR11 / T1RES RT31 TK31 AKO-14123 / 9 EC3-130 XR120C EWPC902 CR32S BL31 EKC201-084B7011 SDU11 / T1RES RC31 RK31 AKO-14712 / 16 EC3-131 XR10C EWPC961 PJ32S RC31 EKC101 SDU11 / T1REBS EC3-133 XR20C IC901 IR33FSOEPOO/c WH31 SDU112 FK202A XT110C IC902 PJ32M RD21 LDU112 FK200X XR02CX ID961 PJZERO LDU151E FK201X/A XR20CX ID961LX SDU12 / TOREB FK202T SDU12 / TORD FK200P SDU12 / TORDC FK201Y/T SDU12 / TORES FK207A LDU152E FK250X MTR6 FK150P FK151X FK151A FK515Y FK151T EVK201 EVK211 EVK221 EKV231

LAE SAE INTEK AKO EVERY/EVCO DIXELL ELIWELL CAREL BETA TEDDINGTON DANFOSS MTR11 / T1RDS RT31 RK31 EKV203 EC3-120 XR110C EWPC901 IR32S RD31 EK-R31 EKC204 MTR11 / T1RES RC31 RK32 EKV204 EC3-130 XR120C EWPC902 IR32Y RT31 EK-R32 EKC101 SDU11 / T1RES RC31-1000 RK33 EKV213 EC3-131 XR130C EWPC961 IR32C BL21 EK-R33 SDU11 / T1REBS RC31- 0100 TK31 EKV222 EC3-110 XR140C EWPC970 CR32S RC31 MCDU11 / T1RDS RC32- 0000 DK31 (PTC) EKV231 EC3-111 XR150C EWPC971 CR32T BL32 MCDU11 / T1RDS/1 RC33 EKV241 EC3-180 XR160C EWPC974 CR32X RC32 MCDU11 /T1RDS/2 DC31 (PTC) EKV251 EC3-181 XR170C EWPC977A CR32Y BL33 MCDU11 / T1RDS/3 EKV253 EC3-185 XR10C EWTC101 PJ32Y RC33 CDC112 / T1RDS FK200X FK200A XR20C EWPX161 PJ32S WH31 CDC112 / T1R3S FK203A FK201A XR40C EWPX161AR PJ32X RD21 CDC112 / T1RBS FK203R FK201T XR60C EWPX170 PJ32C BL22 SPU112 FK207Y FK202A XR02CX EWPX171 IR33FSOEP00/C BL23 SDU12T0RES FK214A FK202T XR03CX EWPX174 IR33F7EN00/C SDU12T0REB FK215A FK203B XR04CX EWPX174AR IR33F7EN00/F SDU12T0RD FK203C XR06CX EWPX177A PJ32M SDU12T0RDC FK203T XR20CX EWPX185 PJZERO LDU151E FK214A XR30CX IC901 PJ32V LDU152E EVK201 XR40CX IC902 PJ32W CDC112T1R2 EVK211 XR60CX ID961 PJ32Z CDC112T1R3B EVK221 XR70CX ID961LX PJEZ-S MP1-15 EVK202 ID970 PJEZ-X MP1-15B4EA EVK212 ID970LX PJEZ-C LD1-15 EVK223 ID971 PJEZ-Y LD2-15 FK209A ID971LX MTR6 FK214 ID974 AT1-5 ID974LX AT2-5 AD2-5 AD3-5 AH1-5 AR1-5

DIXELL UNIVERSAL-J REPLACEMENT GUIDE. For guide purposes only.

The Universal-J can replace all of the following controllers, providing all of their key functions. Some minor functions may not be offered.Note that the table below is not a comparison between the manufacturers listed.

PENN – replaces the MR1PM12R-1C, MR1PM230R-1C, MR2PM12R-1C, MR3PM12R-2C and MR4PM12R-2C.