saybolt viscometer

15
REVA UNIVERSITY A PRESENTATION ON SAYBOLT VISCOMETER Under Guidance of Prof: K.S.NARAYANASWAMY Presented by BEERAPPA RU14MMD02

Upload: beerappa143

Post on 21-Jan-2017

3.184 views

Category:

Education


9 download

TRANSCRIPT

Page 1: saybolt viscometer

REVA UNIVERSITYA PRESENTATION ON

SAYBOLT VISCOMETERUnder Guidance of

Prof: K.S.NARAYANASWAMY

Presented byBEERAPPA

RU14MMD02

Page 2: saybolt viscometer

CONTENTS

• Viscosity • Introduction• Saybolt viscometer• Advantages• Disadvantages• Application

Page 3: saybolt viscometer

Viscosity

• The device used for measurement of viscosity is known as viscometer .

• The viscosity of a fluid is a measure of its resistance to gradual deformation by shear stress or tensile stress.

• The units of viscosity is poise and centipoise .• specific viscosity is the ratio of the viscosity of fluid to the

viscosity of water at 20 degree Celsius. Since the water has a viscosity of 1 cp at 20 degree Celsius.

• Kinematic viscosity is defined as ratio of dynamic viscosity to the density of the fluid.

Page 4: saybolt viscometer

IntroductionDefinition• A device used to measure the viscosity of a fluid. The saybolt

viscometer controls the heat of the fluid and the viscosity is the time is takes the fluid to fill a container.

• Efflux cup viscometers are most commonly used for fieldwork to measure the viscosity of oils, syrups, varnish, paints and Bitumen emulsions.

• The saybolt viscometer, one of the efflux cup viscometers is the standard instrument for testing petroleum products.

•  The testing procedure is quite similar to the capillary-tube viscometers

Page 5: saybolt viscometer

• Efflux time of a specified volume of fluid is measured through fixed orifice at the bottom of a cup to represent the viscosity of the fluid

• To obtain high accuracy the liquid holding vessel and orifice are temperature controlled by immersing them in a thermostatically controlled bath.

• There are three types of orifices available-Universal, Furol, Asphalt.

• The furol and asphalt orifices, respectively, have an efflux time of approximately, one-tenth and one-hundredth that of the universal orifice.

Page 6: saybolt viscometer
Page 7: saybolt viscometer

•  The cup orifice combination should be selected to provide an effllux time within the range of 20 to 100 seconds.

•  Of these types, the universal orifice(saybolt universal viscometer) is most commonly used and its efflux time is designated as saybolt universal seconds(SUS).

•  The universal viscometer measures the time required for 60 cc of sample fluid to flow out through an orifice having dimensions of 0.176 cm in diameter and 1.225 cm in length.

Page 8: saybolt viscometer

• Saybolt universal seconds (t) can be converted to kinematic viscosity (v) by the following equations:When t < 100 secs, v = 0.226t - 195/t CentistokesWhen t >100 secs, v = 0.220t - 135/t Centistokes.

• The viscosity determinations should be conducted in a room free from drafts and rapid changes in temperature the highest degree of accuracy.

Page 9: saybolt viscometer

ADVANTAGES

• It has a digital meter to measure tempertature and so reading is more accurate and precise.

• The coils wrap around the container uniformly so uniform temprature can be obtained.

• Viscosity can be directly compared for two or more liquids.

Page 10: saybolt viscometer

Disadvantages

• The main disadvantage of the capillary tube viscometer is the errors that arise due to the variation in the head loss and other parameters.

• Efflux cup viscometer have some inherent inaccuracies

Page 11: saybolt viscometer

Application

• Efflux viscometer are most commonly used fieldwork to measure the viscosity of oil , syrups, varnish, paints.

• It is used for testing petroleum products.

Page 12: saybolt viscometer
Page 13: saybolt viscometer
Page 14: saybolt viscometer

REFERENCES

• www.Google.com

Page 15: saybolt viscometer

Thank you to all