sb-dn-sec250k security module sb-dn-sec250k can manage 8 independent zones’ arming and alarm. hdl...

12
SB-DN- SEC250K security module SB-DN-SEC250K can manage 8 independent zones’ arming and alarm. HDL -BUS Addressing button

Upload: jessie-floyd

Post on 14-Jan-2016

237 views

Category:

Documents


3 download

TRANSCRIPT

Page 1: SB-DN-SEC250K security module SB-DN-SEC250K can manage 8 independent zones’ arming and alarm. HDL -BUS Addressing button

SB-DN-SEC250K

security module SB-DN-SEC250K can manage 8 independent zones’ arming and alarm.

HDL -BUS

Addressing button

Page 2: SB-DN-SEC250K security module SB-DN-SEC250K can manage 8 independent zones’ arming and alarm. HDL -BUS Addressing button

SB-DN-SEC250K Function setting

Detected?

Sensor start detecting

Buzzer running

Run defend(Siren/ SMS/

AutoDail)

Arm?

Disarmed?

Trespasser has left?

Arm/disarm:Enable/disable security function

Buzzer:To urge the owner/trespasser to disarm/leave

Siren:Alarm

(check more detailed doc for workflow ftp://59.41.255.150/documents/miscellaneous/)

Work flow

Page 3: SB-DN-SEC250K security module SB-DN-SEC250K can manage 8 independent zones’ arming and alarm. HDL -BUS Addressing button

SB-DN-SEC250K

Setup steps:1.Check firmware versions of sensors and security module. (A video has been made to attach to this PPT. ftp://59.41.255.150/softwares/HDL%20tutorial%20video/module%20tutorial%20video/12.%20security%20module/)

2.Enable the security function of sensors.3.Register the sensors in security module and refresh, see if the security module can get the status of sensors. (also you can set some indicators in security module, so that when arming fails you would know which sensor channel fails - e.g., window1

still open, door2 still open…)4.Choose DLP as a user interface to arm and disarm. (better to use DLP because DLP has password for every page – long press the first button and fourth button at the same

time to jump to setting page, ftp://59.41.255.150/documents/miscellaneous/)5.Register the panel in security module6.Find a SD card (<8GB, recommend to use Kingston card) and format it as FAT32, create a folder and name it “special”, put some voice files (.mp3 and sort

them with a header “001”, “002”, “003”… - check the video).7.Check the universal switch list of Z-Audio, especially the “208”, “150” (150 is reserved for folder “special”) and “1-149”.8.Fill in targets in security module and have a test. (check the video)9.Check the “security workflow.doc” (ftp://59.41.255.150/documents/miscellaneous/)

Page 4: SB-DN-SEC250K security module SB-DN-SEC250K can manage 8 independent zones’ arming and alarm. HDL -BUS Addressing button

SB-DN-SEC250K

Enable security function

Assign this channel of sensor to one area of security module.

Sensor setting

Same settings can be applied to other channels.

Page 5: SB-DN-SEC250K security module SB-DN-SEC250K can manage 8 independent zones’ arming and alarm. HDL -BUS Addressing button

SB-DN-SEC250K

Basic information

Security module has built-in battery and so has real time.

Security history

Almighty password:888,888Read history: freeDelete history: password needed.

Page 6: SB-DN-SEC250K security module SB-DN-SEC250K can manage 8 independent zones’ arming and alarm. HDL -BUS Addressing button

SB-DN-SEC250K

Enable security function

Enable security function of security module.

Page 7: SB-DN-SEC250K security module SB-DN-SEC250K can manage 8 independent zones’ arming and alarm. HDL -BUS Addressing button

SB-DN-SEC250K

Register sensors in logic module

Enable and register the sensorsSet sensor type

Security module should be able to get the status of sensors.

Generally just leave it unchecked. When arming procedure is started, the security module will check the status of sensors and determine if it is clear to arm, if it is not, the indicator will be triggered.

Double click to set the indicator targets

Page 8: SB-DN-SEC250K security module SB-DN-SEC250K can manage 8 independent zones’ arming and alarm. HDL -BUS Addressing button

SB-DN-SEC250K

Authorize some devices(generally the user panel) to arm/disarm

Page 9: SB-DN-SEC250K security module SB-DN-SEC250K can manage 8 independent zones’ arming and alarm. HDL -BUS Addressing button

SB-DN-SEC250K

Set arm and disarm commands in DLP

“single on”

Page 10: SB-DN-SEC250K security module SB-DN-SEC250K can manage 8 independent zones’ arming and alarm. HDL -BUS Addressing button

SB-DN-SEC250K

Check the folder “special” in Z-Audio

Page 11: SB-DN-SEC250K security module SB-DN-SEC250K can manage 8 independent zones’ arming and alarm. HDL -BUS Addressing button

SB-DN-SEC250K

Check the universal switch list of Z-Audio, “208”, “150” (reserved for the folder “special”) and “1-149”. Download the list - ftp://59.41.255.150/documents/en_PDF/

Page 12: SB-DN-SEC250K security module SB-DN-SEC250K can manage 8 independent zones’ arming and alarm. HDL -BUS Addressing button

SB-DN-SEC250K

Set warning sound targets

Fill in targets according to customer’s requirements. To do that, it is very important to get familiar with the security workflow. (“security workflow.doc” - ftp://59.41.255.150/documents/miscellaneous/) Below is an example of setting warning sound for “ENTER BUZZER ON”